Sie sind auf Seite 1von 2

piston / valve design

Mechanical Flowmeter for liquids or gaseous media. With ti triggering ti i f a metering t i unit it with ith 270 of f pointer i t of magnetic range. Rugged design in stainless steel. local metering good repeatability dirt-resistant low pressure loss easy adjustment by indicating pointer

Flowmeter Novatron TZ1-...GK


Female thread G1/2 to G2 stainless steel

1.3.
TZ1.GK

GENERAL CHARACTERISTICS

TECHNICAL DATA
G Type PN bar Qmax. rec. l/min H2O

TZ1-015GK006 metering range l/min H2O


2- 6 4 - 20 10 - 60 10 - 100 10 - 150 20 - 250 4 - 20 5 - 40

H mm
210 210 210 210 223 225

L mm
80 80 80 95 105 120

D mm
68 68 68 78 88 102

X mm
15 16 18 24 25 27

weight kg
2.9 2.8 2.7 3.4 3.8 5.1

100 G 1/2 TZ1-015GK... 20 G 3/4 TZ1-020GK... 100 40 100 G1 TZ1-025GK060 60 100 G 1 1/4 TZ1-032GK100 100 150 G 1 1/2 TZ1-040GK150 100 250 G2 TZ1-050GK250 100 Metering range is indicated for horizontally increasing flow. tolerance media temperature average pressure loss stainle es steel 3% of full scale max. 90C 0.25bar at Qmax.

MATERIALS
housing piston/disc spring piston sleeve magnet seal stainless steel 1.4305 stainless steel 1.4571 stainless steel 1.4310 stainless steel 1.4571 bariumferrite (PTFE plated) viton 07.05.2007 page 1 of 2

HONSBERG Instruments GmbH Tenter Weg 2-8 42897 Remscheid Germany Phone +49(0)2191 9672-0 Fax +49(0)2191 9672-40 www.honsberg.com info@honsberg.com

piston / valve design ELECTRICAL DATA


BASIC Standard
No electrical components.

Flowmeter Novatron TZ1-...GK

1.3.
TZ1.GK

BASIC Programme option


integrated micro switch with front switch units see data sheet 1.3.TZ1.ZE

INSTALLATION POSITIONS
Installation position may influence metering range.

METERING SUBSTANCES
water gas/air

oil

aggressive liquids

NOMENCLATURE TZ1TZ1TZ1M015 020 025 032 040 050 G K 006 020 040 060 100 150 250 Programme g option p BASIC Special option VARIO

For combinations see table "technical data".

015

G K

006

nominal diam metering range H2O horizontal

basic type specification Flowmeter Flowmeter with integrated micro switch DN 15 - G1/2 DN 20 - G3/4 DN 25 - G1 DN 32 - G1 1/4 DN 40 - G1 1/2 DN 50 - G2 female thread housing stainless steel 2 - 6 l/min 4 - 20 l/min 5 - 40 l/min 10 - 60 l/min 10 - 100 l/min 10 - 150 l/min 20 - 250 l/min p front switch unit with 10-kOhm-potentiometer diode special range metering range for oil or gas front switch unit 2pol, n.o. or n.c.

IMPORTANT FOR YOUR ORDER


Please indicate flow direction, metering substance and metering range with your order. With viscous liquids please indicate viscosity, temperature and metering substance (metering range on request) gaseous media indicate p pressure ( (relative or absolute), ), temperature p and metering g substance ( (metering g range g on request) q ) With g For additional information concerning options micro switch and front switch see data sheet 1.3.TZ1.ZE.

All technical changes reserved BASIC Standard BASIC Programme option VARIO Special option PLUS Accessories not recommendable 07.05.2007 page 2 of 2

HONSBERG Instruments GmbH Tenter Weg 2-8 42897 Remscheid Germany Phone +49(0)2191 9672-0 Fax +49(0)2191 9672-40 www.honsberg.com info@honsberg.com