Sie sind auf Seite 1von 4

DLW

Enclosed Direct-on-Line Starter

Transforming Energy
into Solution
D.O.L. Starters Start/Stop contacts independent from main contactor
for electric motors up to and from thermal overload relay
18.5 kW, 415 V

Slotted to accept DIN 35mm rail


(quick assembly)

Ground lug
(supplied as standard)

Allows cable connection from


back side of the enclosure

Thermal overload relay reset


integrated to the stop button

Enclosure: IP65
Totally insulated

Wiring diagrams See below the connection diagrams for DLW:

Three phase D.O.L. Starter Single phase D.O.L. Starter


Phase to phase coil supply Separate coil supply
SEPARATE COIL
SUPPLY VOLTAGE

Figure 1 – Control circuit with phase to phase coil supply. Figure 2 – Control circuit with separate coil supply.

When using 230V, 400V, 500V and 690V When using 24V, 48V, 110V, etc. on the
on the reference code, WEG D.O.L. starters reference code, WEG D.O.L. starters (DLW) will
(DLW) will be factory-connected, as per be factory-connected, as per wiring diagrams of
wiring diagrams of figure 1, that is, with phase figure 2, that is, with control circuit to be
to phase coil supply. connected through a separate coil supply.
For other voltages with phase to phase coil
supply, contact WEG.
NOTE: When using remote control, disconnect the circuit at the points marked with the “x” in figures 1 and 2 and connect the external devices (Thermostat, pushbutton, etc), as indicated with dotted lines.

Dimensions
Top*
SIZE 02 SIZE 04 SIZE 06
OA = 4.5mm OA = 4.5mm OA = 6.5mm
Back* B = 150mm B = 180mm B = 205mm
C = 98mm C = 111mm C = 126mm
D = 90mm D = 105mm D = 120mm
E = 155mm E = 185mm E = 210mm

Provision for cable STANDARD


gland fitting Top Bottom Back
Size 02 2 x M20 2 x M20 O18mm

Size 04 2 x M25 2 x M25 O18mm


Bottom*
*Knock-out for cable gland Size 06 2 x M25 2 x M25 O22mm
Selection guide
Three phase D.O.L. Starter

Size 02
Motor power reference(1) DLW max. Contactor Thermal Overload Relay
kW current Rated
Reference code(3)(4)(5) 415V Adjusting
Type operational Type
(A)(2) Range
240V 415V current
AC-3/415V (A)(2) (A)
0,12 - DLW07 -0,8 0,8 CW07.10 7 RW17D-0,8 0,56-0,8
0,18 - DLW07 -1,2 1,2 CW07.10 7 RW17D-1,2 0,8-1,2
0,25 - DLW07 -1,8 1,8 CW07.10 7 RW17D-1,8 1,2-1,8
0,37-0,55 0,75-1 DLW07 -2,8 2,8 CW07.10 7 RW17D-2,8 1,8-2,8
0,75 1,5 DLW07 -4 4 CW07.10 7 RW17D-4 2,8-4
1,1 2,2 DLW07 -6,3 6,3 CW07.10 7 RW17D-6,3 4-6,3
1,5 3 DLW07 -8 7 CW07.10 7 RW17D-8 5,6-8

Size 04
Motor power reference(1) DLW max. Contactor Thermal Overload Relay
kW current Rated
Reference code (3)(4)(5)
415V Adjusting
Type operational Type
(A)(2) Range
240V 415V 690V current
AC-3/415V (A)(2) (A)
- - 0,18 DLW9 -0,4 0,4 CWM9.10 9 RW27D-0,4 0,28-0,4
- - 0,25 DLW9 -0,63 0,36 CWM9.10 9 RW27D-0,63 0,4-0,63
- - 0,37 DLW9 -0,8 0,8 CWM9.10 9 RW27D-0,8 0,56-0,8
- - 0,55-0,75 DLW9 -1,2 1,2 CWM9.10 9 RW27D-1,2 0,8-1,2
- - 1,1 DLW9 -1,8 1,8 CWM9.10 9 RW27D-1,8 1,2-1,8
- - 1,5-2,2 DLW9 -2,8 2,8 CWM9.10 9 RW27D-2,8 1,8-2,8
- - 3 DLW9 -4 4 CWM9.10 9 RW27D-4 2,8-4
- - 4 DLW9 -6,3 6,3 CWM9.10 9 RW27D-6,3 4-6,3
- - 5,5 DLW9 -8 7 CWM9.10 9 RW27D-8 5,6-8
2,2 4 7,5 DLW9 -10 9 CWM9.10 9 RW27D-10 7-10
3 5,5 9,2 DLW12 -12,5 12 CWM12.10 12 RW27D-12,5 8-12,5
- - 11 DLW18 -15 15 CWM18.10 18 RW27D-15 10-15
4 7,5 - DLW18 -17 17 CWM18.10 18 RW27D-17 11-17
- - 15 DLW18 -23 18 CWM18.10 18 RW27D-23 15-23
5,5 11 18,5 DLW25 -23 23 CWM25.10 25 RW27D-23 15-23
7,5 - 22 DLW25 -32 25 CWM25.10 25 RW27D-32 22-32

Size 06
Motor power reference(1) DLW max. Contactor Thermal Overload Relay
kW current Rated
Reference code(3)(4)(5) 415V Adjusting
Type operational Type
(A)(2) Range
240V 415V 690V current
AC-3/415V (A)(2) (A)
- - - DLW32 -32 32 CWM32.10 32 RW27D-32 22-32
9,2 15 30 DLW32 -40 32 CWM32.10 32 RW27D-40 25-40
11 - - DLW40 -40 40 CWM40.10 40 RW27D-40 25-40
- 18,5 37 DLW40 -50 40 CWM40.10 40 RW27D-50 32-50

Replace by code for control voltage

Voltage Control
Voltage 240V 415V 690V
for 50-60Hz Z20 Z25 Z31
NOTES:
(1) Specifications valid only for 50Hz three phase, 4 poles WEG standard motors. These values are only for reference and may change on the number of poles and motor design;
(2) The currents mentioned are only valid for motors with rated voltage up to 415V. For higher voltage values, please contact WEG;
(3) Fill out the reference code with rated voltage. Example: For a 11kW, 415V, 50Hz motor, a DLW25Z25-23 should be used and the wiring diagram is shown on page 2;
(4) This reference code applies to 50/60Hz contactor coil. For 50Hz or 60Hz coils only, please contact WEG;
(5) For contactor coil voltage different to the supply voltage, please contact WEG.
Selection guide
Single phase D.O.L. Starter

Size 02
DLW max. Contactor Thermal Overload Relay
Motor power reference(1)
current Rated
kW Reference code(3)(4)(5) 415V Adjusting
Type operational Type
(A)(2) Range
240V current
AC-3/415V (A)(2) (A)
0,25 DLWM07 -2,8 2,8 CW07.10 7 RW17D-2,8 1,8-2,8
0,37 DLWM07 -4 4 CW07.10 7 RW17D-4 2,8-4
0,55-0,75 DLWM07 -6,3 6,3 CW07.10 7 RW17D-6,3 4-6,3
1,1 DLWM07 -8 7 CW07.10 7 RW17D-8 5,6-8

Size 04
DLW max. Contactor Thermal Overload Relay
Motor power reference(1)
current Rated
kW Reference code (3)(4)(5)
415V Adjusting
Type operational Type
(A)(2) Range
current
240V 480V (A)
AC-3/415V (A)(2)
- 0,25 DLWM9 -1,2 1,2 CWM9.10 9 RW27D-1,2 0,8-1,2
- 0,37 DLWM9 -1,8 1,8 CWM9.10 9 RW27D-1,8 1,2-1,8
- 0,55-0,75 DLWM9 -2,8 2,8 CWM9.10 9 RW27D-2,8 1,8-2,8
- 1,1 DLWM9 -4 4 CWM9.10 9 RW27D-4 2,8-4
- 1,5 DLWM9 -6,3 6,3 CWM9.10 9 RW27D-6,3 4-6,3
- 2,2 DLWM9 -8 7 CWM9.10 9 RW27D-8 5,6-8
- 3 DLWM9 -10 9 CWM9.10 9 RW27D-10 7-10
1,5 3,7 DLWM12 -12,5 12 CWM12.10 12 RW27D-12,5 8-12,5
2,2 - DLWM18 -15 15 CWM18.10 18 RW27D-15 10-15
- - DLWM18 -17 17 CWM18.10 18 RW27D-17 11-17
3 - DLWM18 -23 18 CWM18.10 18 RW27D-23 15-23
- 5,5 DLWM25 -17 17 CWM25.10 25 RW27D-17 11-17
3,7 - DLWM25 -23 23 CWM25.10 25 RW27D-23 15-23
- - DLWM25 -32 25 CWM25.10 25 RW27D-32 22-32

Mod. 963.01/AA/102005 / The values shown are subject to change without prior notice. The information are for reference only.
Size 06
Motor power reference(1) DLW max. Contactor Thermal Overload Relay
kW current Rated
Reference code(3)(4)(5) 415V Adjusting
Type operational Type
(A)(2) Range
current
240V 480V (A)
AC-3/415V (A)(2)
- 7,5 DLWM32 -23 23 CWM32.10 32 RW27D-23 15-23
7,5 - DLWM32 -40 32 CWM32.10 32 RW27D-40 25-40
10 - DLWM40 -50 40 CWM40.10 40 RW27D-50 32-50

Replace by code for control voltage Voltage Control


Voltage 240V 480V
for 50-60Hz Z20 Z28
NOTES:
(1) Specifications valid only for 50Hz single phase, 4 poles WEG standard motors. These values are only for reference and may change on the number of poles and motor design;
(2) The currents mentioned are only valid for motors with rated voltage up to 415V. For higher voltage values, please contact WEG;
(3) Fill out the reference code with rated voltage. Example: For a 3kW, 240V, 50Hz motor, a DLWM18Z20-23 should be used and the wiring diagram is shown on page 2;
(4) This reference code applies to 50/60Hz contactor coil. For 50Hz or 60Hz coils only, please contact WEG;
(5) For contactor coil voltage different to the supply voltage, please contact WEG.

WEG AUSTRALIA PTY. LTD.


3 Dalmore Drive Carribean - Park Industrial Estate
Scoresby 3179 - Melbourne - Victoria
Phone:+61(3)9765-4600 - Fax:+61(3)9753-2088
sales@weg.com.au
http://waa.weg.com.br

Das könnte Ihnen auch gefallen