Sie sind auf Seite 1von 1

Brochures thmatiques/Technical brochures

Non members 76 Euros

High voltage overhead lines. Environmental concerns, procedures, impacts and mitigations
Electricity utilities involved in transmission development, maintenance and operation face increasingly severe challenges as a result of heightened environmental awareness, more comprehansive legislation and standards and growing public expectations and concerns. these trends will have a major influence on the approach of companies to the management of both new projects and existing transmission assets. 22 14, 1999, 104 pp. en anglais/in english Non-members Ref. No. 147 30 Euros
60 Euros

With a view to preventing failures this documents serves to describe how critical damage can occur in the filed and the measures that should be taken to avoid such damage. Typical problems are illustrated to show the defects that can be introduced by inappropriate treatment and construction practices, to indicate the possible long term effects of such defects and to assist in their identification to facilitate the rigourous inspection of composite insulators prior to line commissioning. CE/SC 22 03, 2001, 25 pp. en anglais/in english
Non-members

Ref. No. 184 12 Euros


24 Euros

Diaphragms for lattice steel supports.


Following a review of the available standards worldwide, it became obvious to the WG there was little definitive documentation addressing the application, design or requirement for horizontal diaphragms (plan bracing) within lattice steel supports.SC22 compiled a questionnaire concerning the design "rules" currently employed within the industry addressing its scope to self-supporting and guyed lattice steel supports. 21 responses were received and are published in this brochure. CE/SC 22 08, 2002, 41 pp. en anglais/in english
Non-members

Load control devices on overhead transmission lines.


Electricity utilities need to design overhead lines to withstand potential cascade failures of towers which could occur as a result of exceptional icing or rupture of conductors. Some utilities simply design the lines with section towers at frequent intervals and other utilities use special devices called 'load control devices' (LCD) the function of which is to limit the stresses applied to the towers in cases of exceptional longitudinal loads. CE/SC 22 06, 2000, 20 pp. en anglais/in english
Non-members

Ref. No. 174 12 Euros


24 Euros

Ref. No. 196 20 Euros


40 Euros

Diaphragms for lattice steel supports.


Following a review of the available standards worldwide, it became obvious to the WG there was little definitive documentation addressing the application, design or requirement for horizontal diaphragms (plan bracing) within lattice steel supports.SC22 compiled a questionnaire concerning the design "rules" currently employed within the industry addressing its scope to self-supporting and guyed lattice steel supports. 21 responses were received and are published in this brochure. CE/SC 22 08, 2002, 41 pp. en anglais/in english
Non-members

Management of existing overhead transmission lines.


Can you answer the following questions : Can you quantitatively justify investments in you O/H transmission system ? Can you predict the probability of you next O/H transmission line failure event ? Do you collect the right data when you have a failure event ? Do you know the present capability of you OHTL components ? Could you manage these data effectively if you did collect them ? CE/SC 22 13, 2000, 185 pp. en anglais/in english
Non-members

Ref. No. 175 30 Euros


60 Euros

Ref. No. 196 20 Euros


40 Euros

Guidelines for field measurement of ice loadings on overhead power line conductors.
When criteria for ice loading on overhead transmission lines are established, experiences from existing lines and line networks are of great economical value. This document describes the importance of such data and procedures for collecting them. Guidelines for company routines as well as recommendations for tools, training and observation procedures are given. Includes two sets of observation forms : for collecting fundamental and accurate information on ice loadings and shedding on various conductor types and a simplified set for collecting basic information. CE/SC 22 06.01, 2001, 28 pp. en anglais/in english
Non-members

The design of transmission line support foundations an overview.


Transmission line foundations provide the interlinking component between the support and in-situ soil and/or rock. The interrelationship between the support type and the applied foundation loadings are considered, together with the methods of determining the engineering properties of the in-situ soil and/or rock. Two principal categories of foundations have been considered: separate and compact. The major types applicable to each category are reviewed e.g. monoblock, spead, drilled shaft, pile, anchor, direct embedment of poles, etc CE/SC 22 GT/WG 7, 2002, 75 pp. en anglais/in english
Non-members

Ref. No. 179 12 Euros


24 Euros

Ref. No. 206 26,00 Euros


52,00 Euros

Probabilistic design of overhead transmission lines.


Companion document to "Improved design criteria of overhead transmission lines based on reliability concepts". Contains the technical background of reliability based design in more detail. An output of CIGRE WG22.06 involved in reliability based design of overhead transmission lines for many years. CE/SC 22 06, 2001, 124 pp. en anglais/in english
Non-members

Thermal behaviour of overhead conductors.


In most countries the demand for electric power is constantly increasing, and there is a corresponding requirement to increase the power transferred by transmission and distribution lines. A solution would be to build new lines, but this may not be feasible on account of economic or environmental considerations. Hence, there may be pressure to increase the load transfer capacity of both new and old lines. CE/SC 22 GT/WG 12, 2002, 45 pp. en anglais/in english Ref. No. 207 13,00

Ref. No. 178 35 Euros


70 Euros

Composite insulator handling guide

Catalogue des publications Cigr - 2003

* TVA ajouter pour les pays concerns

Das könnte Ihnen auch gefallen