FIRE ALARM SYSTEM CAUSE & EFFECT M ANNUNCIATION NOTIFICATI

ALARM INDICATION & BUZZER IN MFACP ACTUATE EVACUATION SIGNAL


X X X X X X X X

ACTIVATION OF SMOKE DETECTOR@1 FLR ACTIVATION OF SMOKE DETECTOR@GND. FLR. ACTIVATION OF DUCT DETECTOR@1ST FLR ACTIVATION OF DUCT DETECTOR@GND. FLR. ACTIVATION OF HEAT DETECTOR@1 FLR ACTIVATION OF HEAT DETECTOR@GND. FLR. ACTIVATION OF MANUAL CALL POINT@1 FLR ACTIVATION OF MANUAL CALL POINT@GND. FLR. OTHER STATUS ELECTRIC FIRE PUMP - RUN LOOP OPEN CIRCUIT LOOP SHORT CIRCUIT MASTER ALARM OPEN CIRCUIT MASTER ALARM SHORT CIRCUIT EARTH FAULT FIRE PUMP SYSTEM LOW BATTERY FIRE PUMP POWER FAILURE FIRE PUMP PHASE REVERSAL SPRINKLER CONTROL VALVE- LVL. ROOF SPRINKLER CONTROL VALVE- LVL.1 SPRINKLER CONTROL VALVE-LVL. GRND WATER FLOW- LVL. ROOF WATER FLOW - LVL.1 WATER FLOW -LVL. GRND
ST ST

ST

FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT FAULT FAULT FAULT FAULT FAULT FAULT FAULT FAULT FAULT FAULT FAULT

X X X X X X X X X X X X X X X X X X X X X X X

X X X X X X X X

Fire Alarm Sequence of operations 1.The fire alarm system shall operate as follows: A. Manual Operation - operation of manual fire alarm pull station shall: 1) Identify the individual station on the system control panel and sound the alarm bell at the control panel and remote alarm

DISPLAY/ PRINT CHANGE OF STATUS


X X X X X X X X X X X X X X X X

ACTIVATION OF VOICE EVACUATION

CAUSE EFFECT

SIGNAL TYPE

2) Sound audible alarms and actuate strobes 3) Transmit a signal to the central station B. Activation of area smoke detector, heat detector and flow switch shall cause the following: 1) Provide operation as described for manual call point. C. Activation of any supervisory circuit shall cause the following actions and indications: 1) Record the occurrence of the event, the time of occurrence and the device initiating the event. D. Receipt of a trouble signal at the fire alarm control shall cause the following: 1)Display at the control panel and remote annunciator panels alphanumeric LCD display, the origin or the trouble condition re 2) Activate trouble, audible and visual signals at the fire control panel and remote annunciator. 3) Record the occurrence of the event, the time of occurrence and the device initiating the event.

X X X X X X X X X

panel and remote alarm panel.

TRANSMIT FIRE ALARM SIGNAL TO SUPERVISING STATION TRANSMIT SUPERVISORY SIGNAL TO SUPERVISING STATION TRANSMIT TROUBLE SIGNAL TO SUPERVISING STATION

X X X X X X X X X X X X X X X

RELEASE ALL SLIDING DOOR RELEASE MAGNETICALLY HELD SMOKE DOORS UNLOCK EGRESS

CAUSE & EFFECT MATRIX FOR PRIMARY HEALTH CARE CORPORTATION NOTIFICATION REQUIRED FIRE SAFETY CONTROL

X X X X X X X X X X X X X X X X X X X X X X

X X X

SHUTDOWN ELEVATORS CLOSE SMOKE/FIRE DAMPERS IN RATED WALLS ACTUATE SMOKE EXHAUST ACTUATE SUPPRESSION SYSTEM PREDISCHARGE ALARMS INITIATE SUPPRESSING SYSTEM RELEASING SEQUENCE

X X X

X X X

the trouble condition report.

X X X X

ACTUATE GRAPHIC SYSTEM DISPLAY FLOOR MAP PRESSURIZE STAIRWELLS OTHER SYSTEM SHUTDOWN PROCESS

SUPPLEMENTARY

X X X X X X X X X X X

X X X X X X X X X X X

ACTUATE EXTERIOR STROBE RESPONSE POINT SHUTDOWN AIR HANDLING UNIT

X X X