Sie sind auf Seite 1von 4

The power

to back you up

RESERVE
POWER
Publication No. US-UPS-FL-003 - April 2009

The DataSafe DX calcium flat plate battery offers superior high rate
performance for mission critical 7x24 applications.

Features and Benefits


Capacity: 673 - 5245 watts/cell
Designed for UPS applications

Long life Slide Lock post seal design


Flame retardant cover and container
available

Design life: 20 years @ 25C (77F)


Rated at 100% capacity at initial
discharge

Manufactured in EnerSys ISO 9001:2000


registered production facilities

General Specifications
DataSafe DX
Battery Type

Nominal
Voltage (V)

Watts/Cell*
15 min rate
to 1.67 volts
at 25C (77F)

4DX-5B
4DX-7B
4DX-9B
4DX-11B
4DX-13B
4DX-15B
4DX-17B
4DX-19B
4DX-21B
2DX-19B
2DX-21B
2DX-23B
2DX-25B
2DX-27B
2DX-29B
2DX-31B
2DX-33B
2DX-35B

8
8
8
8
8
8
8
8
8
4
4
4
4
4
4
4
4
4

673
1001
1320
1659
1961
2252
2535
2846
3271
2778
3231
3514
3741
4198
4471
4735
4994
5245

Nominal Dimensions
mm

241
241
241
424
424
424
424
513
513
241
308
308
308
424
424
424
424
424

Length
inch

mm

9.50
9.50
9.50
16.70
16.70
16.70
16.70
20.20
20.20
9.50
12.12
12.12
12.12
16.70
16.70
16.70
16.70
16.70

Width
inch

406
406
406
406
406
406
406
406
406
406
406
406
406
406
406
406
406
406

16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00

Overall Height
Incl. Terminals
mm
inch

558
558
558
576
576
576
576
576
576
576
576
576
576
576
576
576
576
576

22.00
22.00
22.00
22.68
22.68
22.68
22.68
22.68
22.68
22.68
22.68
22.68
22.68
22.68
22.68
22.68
22.68
22.68

Typical Weight
Unpacked
kg
lbs

116.4
137.7
160.5
230.5
253.2
275.5
298.2
354.4
376.6
169.5
203.8
215.1
227.0
266.8
278.6
290.0
301.4
309.0

256.0
303.0
353.0
507.0
557.0
606.0
656.0
781.3
830.3
373.0
448.3
473.0
499.3
587.0
613.0
638.0
663.0
680.0

*Specific Gravity 1.250

The DataSafe DXC calcium flat plate battery offers enhanced cycling
performance for mission critical 7x24 applications.

Features and Benefits


Capacity: 653 - 5088 watts/cell
Enhanced cycling capability

Long life Slide Lock post seal design


Flame retardant cover and container
available

Designed for UPS applications


Design life: 20 years @ 25C (77F)

General Specifications

Rated at 100% capacity at initial


discharge
Watts/Cell*

DataSafe DXC
Battery Type

Nominal
Voltage (V)

15 min rate
to 1.67 volts
at 25C (77F)

4DXC-5B
4DXC-7B
4DXC-9B
4DXC-11B
4DXC-13B
4DXC-15B
4DXC-17B
4DXC-19B
4DXC-21B
2DXC-19B
2DXC-21B
2DXC-23B
2DXC-25B
2DXC-27B
2DXC-29B
2DXC-31B
2DXC-33B
2DXC-35B

8
8
8
8
8
8
8
8
8
4
4
4
4
4
4
4
4
4

653
971
1280
1610
1903
2185
2459
2767
3180
2693
3133
3408
3628
4072
4337
4593
4844
5088

Manufactured in EnerSys ISO 9001:2000


registered production facilities

Nominal Dimensions
mm

241
241
241
424
424
424
424
513
513
241
308
308
308
424
424
424
424
424

Length

inch

mm

9.50
9.50
9.50
16.70
16.70
16.70
16.70
20.20
20.20
9.50
12.12
12.12
12.12
16.70
16.70
16.70
16.70
16.70

406
406
406
406
406
406
406
406
406
406
406
406
406
406
406
406
406
406

Width

inch

16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00
16.00

Overall Height
Incl. Terminals
mm
inch

558
558
558
576
576
576
576
576
576
576
576
576
576
576
576
576
576
576

22.00
22.00
22.00
22.68
22.68
22.68
22.68
22.68
22.68
22.68
22.68
22.68
22.68
22.68
22.68
22.68
22.68
22.68

Typical Weight
Unpacked
lbs

kg

116.4
137.7
160.5
230.5
253.2
275.5
298.2
354.4
376.6
169.5
203.8
215.1
227.0
266.8
278.6
290.0
301.4
309.0

256.0
303.0
353.0
507.0
557.0
606.0
656.0
781.3
830.3
373.0
448.3
473.0
499.3
587.0
613.0
638.0
663.0
680.0

*Specific Gravity 1.250

www.enersys.com

Publication No. US-UPS-FL-003 - April 2009

The DataSafe NPX battery series is designed for high rate discharge
applications. These batteries are used primarily where high power is required
for a short duration.

Features and Benefits


Capacity: 23 - 150 watts/cell

Operates in any position


UL-94 V0 rated, flame retardant plastic

Designed for UPS applications


Design Life: 3-5 years @ 25C (77F)
Approved for shipping as non-hazardous,
non-spillable

100% initial capacity

Manufactured in EnerSys ISO 9001:2000


registered production facilities

UL recognized

General Specifications
Watts/Cell

Nominal Dimensions

Nominal
Voltage (V)

15 min. rate
to 1.67 volts
at 25C (77F)

NPX-35-6 NPX-35-6FR

35

151

5.95

33

1.30

100

3.94

1.43

3.15

12

NPX-50-6 NPX-50-6FR

53

151

5.95

50

1.97

100

3.94

2.09

4.60

NPX-25

NPX-25FR

12

23

90

3.54

70

2.75

107

4.21

1.95

4.30

16.5

NPX-35

NPX-35FR

12

35

151

5.95

65

2.56

100

3.94

2.75

6.06

15

NPX-80

NPX-80FR

12

80

181

7.13

76

2.39

167

6.57

6.35

14.00

8.5

NPX-100

NPX-100FR

12

95

165

6.50

125

4.92

175

6.89

9.70

21.38

7.5

NPX-135

NPX-135FR

12

135

196

7.72

130

5.12

158

6.22

11.94

26.32

6.5

NPX-150

NPX-150FR

12

150

197

7.76

165

6.50

170

6.69

14.29

31.50

DataSafe NPX
Battery Type

FR Type*

mm

Length
inch

mm

Overall Height
Incl. Terminals
mm
inch

Width
inch

Internal
Resistance
(m)

Weight
kg
lbs

All dimensions given are 0.08 inches (2mm). All weights given are 5%
* FR: UL94-V0, Flame Retardant Case and Cover (Oxygen index: 28)
Height is top cover. Overall height, including terminal is dependent on the terminal configuration.

The PowerSafe DDm battery, with its optimized recombination technology and
extra thick plates, provides excellent performance and service life for mission
critical systems.

Features and Benefits


Capacity: 422-3853 watts/cell
Container/Cover Polypropylene flame
retardant standard (UL94 V-0/L.O.I. 28%)
Standard configurations certified to
1997 UBC Zone 4

100% out of box initial battery capacity


Individual steel can provides flexible
configuration and uniform and consistent
compression

Manufactured in EnerSys ISO 9001:2000


registered production facilities

General Specifications
Watts/Cell
PowerSafe DDm
Battery Type

2DDm50-09
2DDm50-13
DDm50-17
2DDm85-13
2DDm85-15
DDm85-21
DDm85-25
DDm85-27
DDm85-33
DDm100-21
DDm100-25
DDm100-27
DDm100-33
DDm125-25
DDm125-27
DDm125-33
www.enersys.com

Nominal Dimensions

Nominal
Voltage (V)

15 min rate
to 1.67 volts
at 25C (77F)

mm

inch

mm

inch

4
4
2
4
4
2
2
2
2
2
2
2
2
2
2
2

422
633
844
1056
1224
1752
2111
2280
2787
1941
2329
2523
3105
2890
3131
3853

188
265
176
265
303
214
252
271
328
214
252
271
328
252
271
328

7.4
10.4
6.9
10.4
11.9
8.4
9.9
10.7
12.9
8.4
9.9
10.7
12.9
9.9
10.7
12.9

165
165
165
165
165
165
165
165
165
165
165
165
165
226
226
226

6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
8.9
8.9
8.9

Length

Height

Depth (can)
mm
inch

333
333
333
519
519
519
519
519
519
590
590
590
590
562
562
562

13.1
13.1
13.1
20.4
20.4
20.4
20.4
20.4
20.4
23.2
23.2
23.2
23.2
22.1
22.1
22.1

Depth (module)
mm
inch

366
366
366
554
554
554
554
554
554
624
624
624
624
597
597
597

14.4
14.4
14.4
21.8
21.8
21.8
21.8
21.8
21.8
24.5
24.5
24.5
24.5
23.5
23.5
23.5

Typical Weight
Unpacked
lbs

kg

34.3
49.5
34.0
75.7
88.5
64.5
74.4
80.8
97.9
73.5
86.5
92.0
115.3
112.3
120.8
144.1

75.4
108.9
74.7
166.5
194.8
142.0
163.7
177.8
217.5
163.4
192.1
204.3
256.3
249.6
268.4
320.3

Publication No. US-UPS-FL-003 - April 2009

DataSafe HX battery range is outstanding for high rate applications and is the
ideal power source to protect vital systems.

Features and Benefits


Capacity: 23-780 watts/cell
Designed specifically for UPS
applications
Conforms to industry standard footprints
(BCI)
Electrochemistry optimized for high rate
performance
Absorbed Glass Mat VRLA technology
Design life of 10 years

Flame retardant case and cover to meet


UL1778
100% initial capacity
Classified as High Performance
UL recognized and IATA approved
(air freight)

Manufactured in EnerSys ISO 9001:2000


registered production facilities

General Specifications
Watts/Cell
8 hr. rate
to 1.75 volts
at 77F/25C

15 min. rate
to 1.67 volts
at 77F/25C

mm

inch

mm

inch

mm

inch

kg

lbs

12
12
6
12
12
12
12
12
12
12
12
12
12
12
12
6

4.5
7
11
11
16
21
28
28
32
44
70
82
94
119
123
200

23
36
53
53
80
100
135
135
150
204
284
336
381
506
540
780

90
151
151
152
181
165
196
197
198
226
259
300
338
338
338
338

3.5
5.9
6.0
6.0
7.1
6.5
7.8
7.7
7.8
8.9
10.2
11.8
13.3
13.3
13.3
13.3

70
65
50
99
76
125
130
130
165
140
175
173
173
173
173
173

2.8
2.6
2.0
3.9
3.0
4.9
5.1
5.1
6.5
5.5
6.9
6.8
6.8
6.8
6.8
6.8

107
100
99
99
167
175
180
169
170
206
208
213
211
272
272
211

4.2
3.9
3.9
3.9
6.6
6.9
7.1
6.7
6.7
8.1
8.2
8.4
8.3
10.7
10.7
8.3

2.0
2.8
2.1
4.1
6.4
10.0
11.8
11.8
14.5
19.5
27.2
32.2
36.3
46.7
48.1
36.3

4.4
6.1
4.7
9.1
14.0
22.0
26.0
26.0
32.0
43.0
60.0
71.0
80.0
103.0
106.0
80.0

12HX25
12HX35
6HX50
12HX50
12HX80
12HX100
12HX135B
12HX135R
12HX150
12HX205
12HX300
12HX330
12HX400
12HX505
12HX540
6HX800

Length

Width

Typical
Weight

Height

Short
Max Discharge
Internal
Circuit
Current
Resistance
Current (A) (Amps-2 min rate)
(m)

300
500
720
720
1000
1500
1800
1800
2400
2775
3175
3700
4225
4510
4775
6200

41
62
93
93
140
171
238
238
277
439
503
586
670
913
961
1272

16.5
13.2
6.1
12.2
8.5
7.1
5.6
5.6
5.0
4.5
3.9
3.4
3.0
2.8
2.6
1.0

DataSafe HX Front Terminal batteries use proven VRLA technology, are


conducive to incorporating monitoring systems and scale easily to larger
capacity UPS systems with one-third fewer parallel battery strings.
F R O N T

Features and Benefits

T E R M I N A L

Capacity: 550-925 watts/cell


Smaller footprint per kilowatt
Simplifies installation
Improves reliability
Complete front access
Eliminates wasted headspace found in
typical 12V top-terminated designs

Easy terminal access simplifies


maintenance
No costly slide out trays required to
obtain terminal access

Manufactured in EnerSys ISO 9001:2000


registered production facilities

General Specifications
Watts/Cell
DataSafe HX-FT
Battery Type

Nominal
Voltage (V)

15 min. rate
to 1.67 volts
at 25C (77F)

16HX550F-FR
16HX800F-FR
16HX925F-FR

16
16
16

550
800
925

Nominal Dimensions
Length
mm
inch

692
692
692

27.2
27.2
27.2

Width
mm

117
177
177

mm

Height
inch

313
313
313

12.3
12.3
12.3

inch

4.6
7.0
7.0

kg

Typical
Weight
lbs

68.5
105.2
112.5

151
232
248

Short Circuit
Current (A)

Internal
Resistance
(m)

4070
6415
6950

4.1
2.6
2.4

Distributed by:

www.enersys.com

EnerSys
P.O. Box 14145
Reading, PA 19612-4145
USA
Tel: +1-610-208-1991
+1-800-538-3627
Fax: +1-610-372-8613

EnerSys Europe
Zurich, Switzerland

EnerSys Asia
Guangdong, China
Tel: +86-755-2689 3639

Printed in USA
2009 EnerSys. All rights reserved.
Trademarks and logos are the property of
EnerSys and its affiliates, except ISO 9000,
which is not the property of EnerSys.

Publication No. US-UPS-FL-003 - April 2009 - Subject to revisions without prior notice. E.&O.E.

DataSafe HX
Battery Type

Nominal Dimensions

Nominal
Voltage
(V)