CHECKLIST FOR INSPECTION OF ELECTRIC ELEVATORS GENERAL NOTES:

(a) (b) See ASME A17.2 - 2007 for detailed Code requirements. OK = meets requirements; NG = no good; NA = not applicable. Periodic Inspection Periodic Test Cat 1 Periodic Test Cat 5 Final Acceptance Evaluation/Test

Address:

1369 HYDE PARK BOULEVARD REAL ESTATE OPERATIONS UNIVERSITY OF CHICAGO

ID No: FREIGHT ELEVATOR 7013 #1 Passenger Rated load: 2000 X Freight Class: Rated speed:

Code Edition: ASME A17.1 2004 lbs. Inspected by: R. DENNIS CHANDLER Date: 125 fpm QEI No: 443 Certifying Organization:

03-16-10 NAESAI

Signature: __________________________________________

OK 1
1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 1.10 1.11 1.12 1.13 1.14 1.15 1.16 1.17 1.18 1.19

NG

NA
2.18 2.19 2.20 2.21 2.22 2.23 2.24 2.25 2.26 2.27 2.28 2.29 Traction drive machines Gears, bearings and flexible couplings Winding drum machine and slack cable device Belt or chain-drive machine Motor generator Absorption of regenerated power AC drives from a DC source Traction sheaves Secondary and deflector sheaves Rope fastenings Terminal stopping devices Car and counterweight safeties

INSIDE OF CAR
Door reopening device Stop switches Operating control devices Sills and car floor Car lighting and receptacles Car emergency signal Car door or gate Door closing force Power closing of doors or gates Power opening of doors or gates Car vision panels and glass car doors Car enclosure Emergency exit Ventilation Signs and operating device symbols Rated load, platform area, and data plate Standby power operation Restricted opening of car or hoistway doors Car ride

X X X X X X X X X X X X X X X X X X X

OK X X

NG

NA

X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

3
3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10 3.11 3.12 3.13 3.14 3.15 3.16 3.17 3.18 3.19 3.20 3.21 3.22 3.23 3.24 3.25

TOP OF CAR
Top-of-car stop switch Car top light and outlet Top-of-car operating device Top-of-car clearance and refuge space Normal terminal stopping device Final and emergency terminal stopping devices Car leveling and anti-creep devices Top emergency exit Floor, and emergency identification numbering Hoistway construction Hoistway smoke control Pipes, wiring, and ducts Windows/projections/setbacks/recesses Hoistway clearances Multiple hoistway Traveling cables and junction boxes Door and gate equipment Car frame and stiles Guide rails, fastening and equipment Governor rope Governor releasing carrier Wire rope fastening and hitch plate Suspension rope Top counterweight clearance Car, overhead, and deflector sheaves

2
2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 2.12 2.13 2.14 2.15 2.16 2.17

MACHINE ROOM
Access to machine space Headroom Lighting and receptacles Machine space Housekeeping Ventilation Fire extinguisher Pipes, wiring, and ducts Guarding of exposed auxiliary equipment Numbering of elevators, machines, and disconnect switches Disconnecting means and control Controller wiring, fuses, grounding, etc. Governor, overspeed switch, and seal Code data plate Static control Overhead beam and fastenings Drive machine brake

X X X X X X X X X X X X X X X X X

CHECKLIST FOR INSPECTION OF ELECTRIC ELEVATORS (Back) OK X X X NG NA


4.11 4.12 Separate counterweight hoistway Standby power selection switch

OK

NG

3.26 3.27 3.28 3.29 3.34

Broken rope, chain, or tape switch Crosshead data plate Counterweight/counterweight buffer Counterweight safeties Compensating ropes and chains

NA X X

5 X X
5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10

PIT
Pit access/lighting/stop switch/condition Bottom clearance/runby/refuge space Final/Em. terminal stopping devices Normal terminal stopping devices Traveling cables Governor-rope tension devices Car frame and platform Car safeties and guiding members Buffers/Em. terminal speed devices Compensating ropes/chains/sheaves

4
4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10

OUTSIDE HOISTWAY
Car platform guard Hoistway doors Vision panels Hoistway door locking devices Access to hoistway Power closing of hoistway doors Sequence operation Hoistway enclosure Elevator parking devices Emergency doors blind hoistway

X X X X X X X X X X

X X X X X X X X X X X X

6
6.1 6.2

FIREFIGHTERS SERVICE
Phase I Phase II -

The above checklist form ASME A134C1, has been computer enhanced by Continental Hoisting Consultants, Inc. The original A134C1 may be obtained from ASME Order Dept., 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300 1.800.843.2763

PERFORMANCE DATA
Make: CEC/OTIS Door entrance type:

SSSO

Installation date: 02-10 Door entrance size:

# of landings:

83 FULL

in

ACTUAL SPEED:
Up - FPM (feet per minute) Down - FPM (feet per minute) Up (1) - Seconds Down (1) - Seconds

EMPTY
125 125 12.4 11.9 7.1 7.2

11 # of openings: 11 F X 40 in Typical floor rise: REMARKS

0 R 9 ft

PERFORMANCE TIMES: Time from start of door closing to doors open 32 in. (813mm) at adjacent floor. MOTION TIME: Brake to brake
Up (1) - Seconds Down (1) - Seconds

DOOR TIMES: Full open to full close - seconds


Door open Door close Long (hall call) dwell Short (car call) dwell Detector (door ray) hold Nudging (Time/closing speed/closing force) Closing pressure (between 1/3 & 2/3) - max. 30 lbf.

FRONT
2.9 3.8 5.9 3.3 4.1 40 25

REAR

REMARKS

GFR-CAR RIDE QUALITY: g-force rate


Start Accel Decel Stop Jerk .09 .06 .05 .07 8.1

EMPTY
UP UP UP UP UP .08 .06 .05 .03 7.3 DN DN DN DN DN

OPTIMAL RANGE
.02gs - .12gs .02gs - .12gs .02gs - .12gs .02gs - .12gs <15.0 USED LIFE (in months) 2 EST. LIFE (in months) 238

REMARKS

ROPE DATA
LOCATION OF ROPES Hoist Drum Counterweight Car Counterweight Governor - Car Governor - Counterweight Compensation Safety Category 1 Test Date: Maintenance Provider: MATERIALS TS NUMBER 4 SIZE AND CONSTRUCTION 5/8 8 X 19 REMARKS OK

STEEL

3/8 8 X 19

298

OK

SAFETY TEST DATA


Category 5 Test Date: ANDERSON ELEVATOR COMPANY Car Safety Type: Counterweight Safety Type:

Copyright Continental Hoisting Consultants, Inc. 1997Revised 2011 Elevator Safety Is No Accident