SORMAT THROUGH BOLT S-KA OPTION 1

TRUSTED FIXINGS
SINCE 1970.

ONE IS ENOUGH
IF ITS SORMAT
SORMAT S-KA THROUGH BOLT ETA OPTION 1
Sormats new S-KA through bolt in ETA Option 1 guarantees maximum performance and security
in every situation. This makes it suitable for both uncracked concrete, e.g. on floors, and cracked
concrete, e.g. in ceilings. One is enough: a reliable, safe and economical choice for all needs.
Besides great performance, the new S-KA through bolt in ETA Option 1 reduces costs. It is designed
to replace your current through bolt range from option 1 to 12. This means you can reduce your
warehouse costs and always have a suitable through bolt at hand.
The S-KA through bolt is also designed for medium heavy and heavy fixings in hard embedments
like solid brick (max. M8) and natural stone. A ready-to-install anchor is particularly suitable for
through fixings.

MAIN BENEFITS OF NEW, IMPROVED SORMAT S-KA THROUGH BOLT:


High pull-out loads especially in uncracked concrete
Easier anchor installation especially with M12 and M16
Pull-out loads can be increased with higher concrete grades
Smaller minimum spacings and edge distances
Deeper embedment depths (except M8)
Adjusted fixture thicknesses
Longer threads gives more flexibility in use
Improved tensile loads for both cracked and non-cracked concrete
Improved and separately available shear load resistances

For full through bolt range (S-KAK and S-KAH) see the Sormat catalogue.

NEW FEATURES

Punched bolt head


prevents thread
destruction while
hammering.

Longer thread lengths


gives flexibility
in installation.

New place and size of top


knurls gives improved
pull-through resistance
and setting behaviour.

New place and size of


bottom knurls gives
improved grip and
quick tightening.

Shorter slot lengths


gives improved pullthrough resistance.

METAL ANCHORS
THROUGH BOLT

S-KA

Steel, zinc plated

This zinc plated through bolt is a torque-controlled expansion anchor for use in cracked and non-cracked concrete. It
is also suitable for installations in hard base materials such as solid brick (max. M8) or natural stone. The anchor is
preassembled and can be installed directly through the fixture. It is suitable for indoor and mainly dry applications.

RANGE AND PACKAGES


TYPE

6/15*
6/50*
8/10
8/30
8/50
8/85
10/10
10/20
10/30
10/50
10/80
12/5
12/20
12/30
12/50
12/65
12/80
12/155*
16/5
16/20
16/50
16/60
16/95*
20/20*
20/70*
20/130*

t fix

mm

mm

65
100
72
92
112
147
92
102
112
132
162
103
118
128
148
163
178
253
123
138
168
178
213
170
220
280

15
50
10
30
50
85
10
20
30
50
80
5
20
30
50
65
80
155
5
20
50
60
95
20
70
130

CODE

00102
00104
01112
01114
01116
01118
01132
01135
01136
01137
01139
01150
01152
01153
01154
01155
01157
00162
01170
01171
01173
01175
00176
00180
00182
00184

PACKAGES

WEIGHT

BOX/OUTER BOX/PALLET

KG/1000 PCS

100/500/28000
100/500/28000
50/250/14000
50/250/14000
40/200/11200
40/200/11200
40/200/11200
25/125/7000
25/125/7000
25/125/7000
25/125/7000
20/100/5600
20/100/5600
20/100/5600
20/100/5600
20/100/5600
20/100/5600
10/50/2800
10/50/2800
10/50/2800
10/50/2800
10/50/2800
10/50/2800
5/25/1400
5/25/1400
5/25/1050

15,4
22,7
29,1
35,3
41,4
52,1
59,2
64,1
69,1
78,9
93,7
95,3
106,0
113,1
127,3
138,0
148,7
230,6
201,6
221,7
261,9
275,3
350,1
448,3
570,2
717,8

* Do not belong to ETA.

CUSTOM RANGE AND PACKAGES


SIZE

6x40*
8x50*
10x60*
16x90*

* Do not belong to ETA.

t fix

mm

mm

40
52
62
90

2
2
3
3

CODE

00100
00110
00130
00169

PACKAGES

WEIGHT

BOX/OUTER BOX/PALLET

KG/1000 PCS

150/750/42000
100/500/28000
50/250/14000
10/50/2800

10,4
22,2
44,4
159,4

METAL ANCHORS
THROUGH BOLT
INSTALLATION PARAMETERS AND CAPACITIES
FIXING DETAILS
TYPE

FIXING DETAILS

PERMISSIBLE LOADS1) 2) IN kN
IN UNCRACKED C20/25
Option 1 - Design Method A

ANCHOR AND FIXTURE DETAILS

size

TENSION

INSTALLATION DATA

df

SW

tfix

d0

h1

hnom

hef

Tinst

SHEAR 3)

Nsk

Vsk

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

Nm

6 / 15 4)
6 / 50 4)
8 / 10
8 / 30
8 / 50
8 / 85
10 / 10
10 / 20
10 / 30
10 / 50
10 / 80
12 / 5
12 / 20
12 / 30
12 / 50
12 / 65
12 / 80
12 / 155 4)
16 / 5
16 / 20
16 / 50
16 / 60
16 / 95 4)
20 / 20 4)
20 / 70 4)
20 / 130 4)

M6
M6
M8
M8
M8
M8
M10
M10
M10
M10
M10
M12
M12
M12
M12
M12
M12
M12
M16
M16
M16
M16
M16
M20
M20
M20

65
100
72
92
112
147
92
102
112
132
162
103
118
128
148
163
178
253
123
138
168
178
213
170
220
280

7
7
9
9
9
9
12
12
12
12
12
14
14
14
14
14
14
14
18
18
18
18
18
22
22
22

28
28
32
52
72
107
47
57
67
87
115
53
68
78
98
113
115
46
65
80
110
115
55
55
55
55

10
10
13
13
13
13
17
17
17
17
17
19
19
19
19
19
19
19
24
24
24
24
24
30
30
30

15
50
10
30
50
85
10
20
30
50
80
5
20
30
50
65
80
155
5
20
50
60
95
20
70
130

6
6
8
8
8
8
10
10
10
10
10
12
12
12
12
12
12
12
16
16
16
16
16
20
20
20

50
50
60
60
60
60
75
75
75
75
75
90
90
90
90
90
90
90
110
110
110
110
110
130
130
130

40
40
50
50
50
50
68
68
68
68
68
81
81
81
81
81
81
81
96
96
96
96
96
120
120
120

35
35
45
45
45
45
60
60
60
60
60
70
70
70
70
70
70
70
85
85
85
85
85
110
110
110

7
7
20
20
20
20
35
35
35
35
35
50
50
50
50
50
50
50
120
120
120
120
120
240
240
240

1,8
1,8
3,6
3,6
3,6
3,6
6,3
6,3
6,3
6,3
6,3
7,9
7,9
7,9
7,9
7,9
7,9
6,4
16,7
16,7
16,7
16,7
10,0
13,9
13,9
13,9

1,8
1,8
4,8
4,8
4,8
4,8
8,7
8,7
8,7
8,7
8,7
11,0
11,0
11,0
11,0
11,0
11,0
6,4
21,0
21,0
21,0
21,0
10,0
13,9
13,9
13,9

6 x 40 4)
8 x 50 4)
10 x 60 4)
16 x 90 4)

M6
M8
M10
M16

40
52
62
90

7
9
12
18

18
23
26
43

10
13
17
24

2
2
3
3

6
8
10
16

35
45
50
80

30
40
40
70

25
30
30
60

7
18
30
100

1,4
1,6
2,1
7,5

1,4
1,6
2,1
7,5

1)
Load figures include the resistances partial safety factors as per approvals and a partial safety factor on the action of F= 1.4. Load figures apply for a rebar spacing s 15 cm or alternatively for a
rebar spacing s 10 cm in combination with a rebar diameter of ds 10 mm. 2) Concrete is considered uncracked when the value of tension within the concrete is L + R 0. In the absence of detailed
verification R = 3 N/mm2 can be assumed (L equals the tension within the concrete as a result of external loads, forces on anchor included; L equals the tension coming from shrinkage or creep of
the concrete, as well as displacements of supports or temperature variations). 3) Shear load figures apply for an anchor without influence of a concrete edge. For shear loads close to an edge (c 10 x
hef), concrete edge failure has to be checked as per ETAG, Annex C, Design Method A. 4) Not part of ETA approvals. Figures are manufacturers recommendations.

Size
L
df
SW
tfix
d0
h1
hnom
hef
f
Tinst

1.
2-3.
4.
5.

Drill a hole according to the instructions above.


Clean the hole using the metal brush and the pump.
Hammer in the anchor.
Tighten the nut using the correct installation torque.

Nominal size
Total length
Hole in fixture
Nut width across flats / pit size
Fixture thickness
Drill hole diameter
Minimum hole depth
Nominal setting depth
Effective anchorage depth
Thread length
Installation torque

1-2008

Sormat Oy, Harjutie 5


FIN-21290 RUSKO, FINLAND
Tel +358 207 940 200
Fax +358 201 76 3888
www.sormat.com