Sie sind auf Seite 1von 19

Installing Flexi Multiradio 10 BTS optional sub-modules

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

6 Installing Flexi Multiradio 10 BTS optional sub-modules


6.1 Installing Flexi Multiradio 10 BTS Power Distribution SubModule (FPFD)
Before you start If cable entries are installed, remove them. Steps Remove the FPFD dummy unit as follows: Undo the screws holding the FSMx core in place. Pull out the core. Remove the three screws holding the FPFD dummy unit in place.

Leave the other dummy units in place if you are not installing any other optional submodules.

18

Id:0900d80580988089 Confidential

DN09107819

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

Installing Flexi Multiradio 10 BTS optional sub-modules

a)

b)

c)

Figure 7

Removing dummy unit

DN09107819

Id:0900d80580988089 Confidential

19

Installing Flexi Multiradio 10 BTS optional sub-modules

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

Remove the rubber plugs on the core and the FPFD.

Figure 8

Removing rubber plugs

Insert the connection card to the slot on the FSMx core. The connection card for the FPFD looks identical with the transmission sub-module connection card. Make sure you are inserting the correct card.

20

Id:0900d80580988089 Confidential

DN09107819

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

Installing Flexi Multiradio 10 BTS optional sub-modules

Figure 9

Inserting connection card

DN09107819

Id:0900d80580988089 Confidential

21

Installing Flexi Multiradio 10 BTS optional sub-modules

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

Remove the DC screw terminal cover from the FPFD sub-module.

Figure 10

Removing DC screw terminal cover

Loosen the screw terminals with an Allen key.

Figure 11

Loosening screw terminals

22

Id:0900d80580988089 Confidential

DN09107819

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

Installing Flexi Multiradio 10 BTS optional sub-modules

Remove the IP plugs from the cable glands.

Figure 12

Removing IP plugs

Remove cable glands heads.

Figure 13

Removing cable glands heads

Strip the DC input cable for 16 mm. The cable size range for the DC input cable is 6 to 25 mm2 and the outer cable diameter 4 to 11 mm.

If your DC input cable is coming from Flexi Power Module (FPMA) (cable code 995069), the pre-cut guide mark for cable stripping is at 11 mm. Make a new cut at 16 mm and then strip the cable.

DN09107819

Id:0900d80580988089 Confidential

23

Installing Flexi Multiradio 10 BTS optional sub-modules

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

If the cable diameter is greater than 6 mm, remove the inner rings from the cable glands.

Figure 14

Removing inner rings from cable glands

Thread your DC input cable through the cable glands. Use lubricant if necessary.

Figure 15

Threading DC input cable through cable glands

Replace the inner cable gland with the DC input cable routed through it.

Figure 16

Replacing inner cable gland

24

Id:0900d80580988089 Confidential

DN09107819

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

Installing Flexi Multiradio 10 BTS optional sub-modules

Insert the DC input cable to the inner screw terminal and tighten it to 4 Nm with an Allen key. NOTICE: The edge of the cable insulation should be visible before tightening the screw terminal.

Figure 17

Tightening inner screw terminal

Tighten the inner cable gland.

Figure 18

Tightening inner cable gland

DN09107819

Id:0900d80580988089 Confidential

25

Installing Flexi Multiradio 10 BTS optional sub-modules

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

Replace the outer cable gland with the DC input cable routed through it.

Figure 19

Replacing outer cable gland

Insert the DC input cable to the outer screw terminal and tighten it to 4 Nm with an Allen key. NOTICE: The edge of the cable insulation should be visible before tightening the screw terminal.

Figure 20

Tightening outer screw terminal

26

Id:0900d80580988089 Confidential

DN09107819

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

Installing Flexi Multiradio 10 BTS optional sub-modules

Tighten the outer cable gland.

Figure 21

Tightening outer cable gland

Check with multi-meter the resistance between +/- terminal screw and chassis. The resistance should be Ms.

DN09107819

Id:0900d80580988089 Confidential

27

Installing Flexi Multiradio 10 BTS optional sub-modules

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

Replace the DC screw terminal cover and tighten the screws for 2 Nm.

Figure 22

Replacing DC screw terminal cover

28

Id:0900d80580988089 Confidential

DN09107819

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

Installing Flexi Multiradio 10 BTS optional sub-modules

Align the FPFD with the guide pin on the FSMx core, and push the FPFD in place.

Figure 23

Installing FPFD

DN09107819

Id:0900d80580988089 Confidential

29

Installing Flexi Multiradio 10 BTS optional sub-modules

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

Fix the FPFD with 3 x M5x25 screws (included in the accessory bag) and tighten to 4.0 Nm.

Figure 24

Fixing FPFD

Route the DC input cable. Route the DC input cable, as shown in Figure 25 Routing DC input cable between FPFD and transmission sub-module.

If transmission sub-module is not used, the DC input cable can be routed between FPFD and dummy unit.

30

Id:0900d80580988089 Confidential

DN09107819

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

Installing Flexi Multiradio 10 BTS optional sub-modules

Figure 25

Routing DC input cable between FPFD and transmission sub-module

Re-insert the module core and fix the screws.

DN09107819

Id:0900d80580988089 Confidential

31

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

6.2

Installing Flexi Multiradio 10 BTS optional Transmission Sub-Module (FTIF)


Purpose Flexi Multiradio System Module core (FSMF/G) has an integrated Gigabit Ethernet and optical Ethernet transport interface available on the front panel, however, if more or other Ethernet interfaces are required then install an optional transmission sub-module (FTIF). The sub-module is also mandatory in co-location cases when a backhaul connection or synchronization is done through time-division multiplexing (TDM). Before you start The System Module has to be powered off before installing or replacing the transmission sub-module. If cable entries are installed, remove them. Steps

Remove the FTIF dummy unit as follows: Undo the screws holding the FSMx core in place. Pull out the core. Remove the four screws holding the FTIF dummy unit in place.

Leave the other dummy units in place if you are not installing any other optional submodules.

32

Id:0900d8058098adf6 Confidential

DN09107819

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

a)

b) a)

c) a)

Figure 26

Removing dummy unit

DN09107819

Id:0900d8058098adf6 Confidential

33

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

Remove the rubber plugs on the core and the transmission sub-module.

Figure 27

Removing rubber plugs

Insert the connection card to the slot on the FSMx core. The transmission sub-module connection card looks identical with the connection card for the FPFD. Make sure you are inserting the correct card.

34

Id:0900d8058098adf6 Confidential

DN09107819

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

Figure 28

Inserting connection card

Align the transmission sub-module with the guide pin on the FSMx core and push the sub-module in place.

Figure 29

Installing transmission sub-module

Fix the transmission sub-module with 4 x M5x25 screws (included in the accessory bag) and tighten to 4.0 Nm. Do not reuse dummy unit screws.

DN09107819

Id:0900d8058098adf6 Confidential

35

Installing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations

Figure 30

Fixing transmission sub-module

Re-insert the module core and fix the screws.

36

Id:0900d8058098adf6 Confidential

DN09107819

Das könnte Ihnen auch gefallen