Beruflich Dokumente
Kultur Dokumente
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
Examiner
DASPAN FWANGSHAK
TARE WT SWL
Qualifications FMLP, LEEA, NDT LEVEL II (MT, PT & UT) GROSS WT Proof Load Applied Date of next
Examination
Description of Equipment
SHIPPING SKID ASSEMBLY A Steel Construction Shipping Skid Assembly in Dimension 17.7m X 0.80m X 1.0m (Length X Width X Height) c/w 4 Lifting Points
M15773-03A
6.30 Tonnes
19.94 Tonnes
N/A 16-07-14
Sling #: 508901-2-1
1set
Fitted with 28m X 296/266 legged unequal length wire rope sling c/w Quad Master Link Assembly @one end and Ferrule Secure Thimble Eyes @ both ends
N/A
N/A
4pcs
2 pcs
21400 LBS
Cert No.
NOT SEEN NOT SEEN
SWL:
13.64 Tonnes
31.1 Tonnes Onshore/15.5 Tonnes offshore @ 0-30
SPECIFICATION: EN 970, ASME B 30.9, ASME B 30.26 MPI METHOD: Wet Visible
PARTS EXAMINED: 40 Lifting Points & Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: FMC TECHNOLOGIES
We hereby certify that on 17/01/2014 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination
Revision No: R01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
Qualifications FMLP, LEEA, NDT LEVEL II (MT, PT & UT) Proof Load Applied Date of next
Examination
Description of Equipment
GROSS WT
47440174-00001-03
A Steel Construction THD Tool Skid in Dimension 2.16m X 1.86m X 2.5m (Length X Width X Height) c/w 4 Lifting Points
5420 LBS
20000 LBS
25420 LBS
40840 LBS
14-07-14
Cert No.
11/0332/03
SWL:
20000 LBS
PARTS EXAMINED: 4 Lifting Point & Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: FMC TECHNOLOGIES
We hereby certify that on 15/01/2014 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination
Revision No: R01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
Qualifications FMLP, LEEA, NDT LEVEL II (MT, PT & UT) GROSS WT Proof Load Applied Date of next
Examination
Description of Equipment
GNL/20796/02
Fitted with 26mm X 10ft X 4 legged IWRC wire rope sling c/w Quad Master Link Assembly with hard eyes @ all ends.
N/A
18.2 Tonnes @ 0 - 90
N/A
N/A
14-07-14
4 pcs
9.5 Tonnes
PARTS EXAMINED: 4 Lifting Point & Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: FMC TECHNOLOGIES
We hereby certify that on 15/01/2014 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination
Revision No: R01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
Qualifications FMLP, LEEA, NDT LEVEL II (MT, PT & UT) GROSS WT Proof Load Applied Date of next
Examination
Description of Equipment
47440174-00001-02
A Steel Construction THD Tool Skid in Dimension 2.16m X 1.86m X 2.5m (Length X Width X Height) c/w 4 Lifting Points
5420 LBS
20000 LBS
25420 LBS
40840 LBS
14-07-14
Cert No.
11/0332/02
SWL:
20000 LBS
PARTS EXAMINED: 4 Lifting Point & Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: FMC TECHNOLOGIES
We hereby certify that on 15/01/2014 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination
Revision No: R01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
Qualifications FMLP, LEEA, NDT LEVEL II (MT, PT & UT) GROSS WT Proof Load Applied Date of next
Examination
Description of Equipment
GNL/20796/01
Fitted with 26mm X 10ft X 4 legged IWRC wire rope sling c/w Quad Master Link Assembly with hard eyes @ all ends.
N/A
18.2 Tonnes @ 0 - 90
N/A
N/A
14-07-14
4 pcs
9.5 Tonnes
PARTS EXAMINED: 4 Lifting Point & Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: FMC TECHNOLOGIES
We hereby certify that on 15/01/2014 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination
Revision No: R01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
Qualifications FMLP, LEEA, NDT LEVEL II (MT, PT & UT) GROSS WT Proof Load Applied Date of next
Examination
Description of Equipment
A Steel Construction Shipping Skid Assembly in Dimension 3.16m X 1.74m X 2.06m (Length X Width X Height) c/w 4 Lifting Points Fitted with 1 X 10ft X 4 legged IWRC wire rope sling c/w Quad Master Link Assembly with hard eyes @ all ends.
7350 LBS
20000 LBS
547000 LBS
370873-1-3
1 set
N/A
N/A
N/A
4 pcs
9.5 Tonnes
Cert No.
11/0332/03
SWL:
20000 LBS
Proof Load Applied: 30000 LBS, Each pad eye tested to 12500 LBS
JOP-020 White Contrast Aid
SPECIFICATION: LOLER, ASME B30.9, ASME B30.26 MPI METHOD: Wet Visible
PARTS EXAMINED: 4 Lifting Point & Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: FMC TECHNOLOGIES
We hereby certify that on 15/01/2014 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination
Revision No: R01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
Examiner
DASPAN FWANGSHAK
TARE WT SWL
Qualifications FMLP, LEEA, NDT LEVEL II (MT, PT & UT) GROSS WT Proof Load Applied Date of next
Examination
Description of Equipment
SUBSEA ACCUMULATOR SKID 2013-06-424H 1 A Steel Construction Subsea Accumulator skid in Dimension 4.27m X 2.44m X 3.3m (Length X Width X Height) c/w 4 Lifting Points 14300 LBS N/A 14300 LBS N/A 17-07-14
Sling #:
513865-5-1 1set
Fitted with 44mm X10ft X single legged wire rope sling c/w Master Link @one end and Ferrule Secure Thimble Eyes @ both ends
35 Tonnes
Cert No.
NOT SEEN NOT SEEN
SWL: N/A
28 Tonnes Onshore, 14 Tonnes Offshore @ Vertical Lift
PARTS EXAMINED: 1 Lifting Point & Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: FMC TECHNOLOGIES
We hereby certify that on 18/01/2014 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination
Revision No: R01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
Examiner
DASPAN FWANGSHAK
TARE WT SWL
Qualifications FMLP, LEEA, NDT LEVEL II (MT, PT & UT) GROSS WT Proof Load Applied Date of next
Examination
Description of Equipment
SUBSEA ACCUMULATOR SKID 2013-06-1025H 1 A Steel Construction Subsea Accumulator skid in Dimension 4.27m X 2.44m X 3.3m (Length X Width X Height) c/w 4 Lifting Points 14300 LBS N/A 14300 LBS N/A 17-07-14
Sling #:
513865-5-2 1set
Fitted with 44mm X 10 ft X 1 leg wire rope sling c/w Master Link @one end and Ferrule Secure Thimble Eyes @ both ends
1pc
35 Tonnes
Cert No.
NOT SEEN NOT SEEN
SWL: N/A
28 Tonnes Onshore, 14 Tonnes Offshore @ Vertical Lift
SPECIFICATION: BS EN 970, ASME B30.9, ASME B 30.26 MPI METHOD: Wet Visible
PARTS EXAMINED: 1 Lifting Point & Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: FMC TECHNOLOGIES
We hereby certify that on 18/01/2014 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination
Revision No: R01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
Examiner
DASPAN FWANGSHAK
TARE WT SWL
Qualifications FMLP, LEEA, NDT LEVEL II (MT, PT & UT) GROSS WT Proof Load Applied Date of next
Examination
Description of Equipment
A Steel Construction Shipping Skid Assembly in Dimension 17.7m X 0.80m X 1.00m (Length X Width X Height) c/w 4 Lifting Points
6.30 Tonnes
13.64 Tonnes
19.94 Tonnes
39.88 Tonnes
16-07-14
Sling #: 508901-2-2
1set
Fitted with 28mm X 29 6/ 23 6 X double legged unequal length wire rope sling c/w Quad Master Link Assembly @one end and Ferrule Secure Thimble Eyes @ both ends Bow safety pin shackles
Shackle ID: M2/E, M2/F, M2/G, M2/H Turn Buckles ID: M2/6, M2/5
4 pcs
17 Tonnes
2 pcs
21400 LBS
Cert No.
NOT SEEN NOT SEEN
SWL:
13.64 Tonnes
31.1 Tonnes Onshore/ 15.5 Tonnes offshore @ 0 - 30
SPECIFICATION: EN 970, ASME B 30.9, ASME B 30.26 MPI METHOD: Wet Visible
PARTS EXAMINED: 40 Lifting Points & Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: FMC TECHNOLOGIES
We hereby certify that on 17/01/2014 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Name of Inspector: DASPAN FWANGSHAK Conducting Examination Conducting: Examination only
Revision No: R01 Effective Date: 29th August 2013 Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
Examiner
DASPAN FWANGSHAK
TARE WT SWL
Qualifications FMLP, LEEA, NDT LEVEL II (MT, PT & UT) GROSS WT Proof Load Applied Date of next
Examination
Description of Equipment
SHIPPING SKID ASSEMBLY 1 pc A Steel Construction Shipping Skid Assembly in Dimension 17.7m X 0.80m X 1.00m (Length X Width X Height) c/w 4 Lifting Points 6.3 Tonnes 13.64 Tonnes 19.94 Tonnes N/A 16-07-14
M15778-02A
SPECIFICATION: BS EN 970, ASME B 30.9, ASME B 30.26 MPI METHOD: Wet Visible
PARTS EXAMINED: 1 Lifting Point & Entire body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: FMC TECHNOLOGIES
We hereby certify that on 17/01/2014 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination
Revision No: R01