Sie sind auf Seite 1von 8

Coiled Tubes

Material Specification HS-110TM


HS-110 CMTM
(Continuously milled tubing)

PHYSICAL PROPERTIES

Minimum yield strength 110,000 psi


Minimum tensile strength 115,000 psi
Minimum Elongation 22%
Maximum Hardness 28C Rockwell

CHEMICAL COMPOSITION - %

Carbon 0.10 0.15 range


Manganese 1.00 max
Phosphorus 0.02 max
Sulfur 0.005 max
Silicon 0.40 max
Chromium 0.50 0.70 range
Copper 0.40 max
Nickel 0.30 max
Molybdenum 0.250 0.45 range

STEEL ALLOY DESCRIPTION

A-606 type 4 Molly UHS

CONTACT INFO
Tenaris Coiled Tubes
8615 E. Sam Houston Pkwy N.
77044 Houston Texas USA
coiledtubesales@tenaris.com
(1) 281 458 2883 tel
(1) 281 458 2886 fax

HS-110 GRADE*
DIMENSIONS
(Inches)

NOMINAL
WEIGHT
Lbs. / ft.

O.D.
SPECIFIED

O.D.
(mm)

WALL
SPECIFIED

WALL
(mm)

WALL
MINIMUM

I.D.
CALCULATED

1.500

38.1

1.750

44.5

2.000

50.8

2.375

60.3

0.125
0.134
0.145
0.156
0.175
0.190
0.125
0.134
0.145
0.156
0.175
0.190
0.204
0.125
0.134
0.145
0.156
0.175
0.190
0.204
0.125
0.134
0.145
0.156
0.175
0.190
0.204

3.18
3.40
3.68
3.96
4.45
4.83
3.18
3.40
3.68
3.96
4.45
4.83
5.18
3.18
3.40
3.68
3.96
4.45
4.83
5.18
3.18
3.40
3.68
3.96
4.45
4.83
5.18

0.120
0.128
0.138
0.148
0.167
0.180
0.120
0.128
0.138
0.148
0.167
0.180
0.195
0.120
0.128
0.138
0.148
0.167
0.180
0.195
0.120
0.128
0.138
0.148
0.167
0.180
0.195

1.250
1.232
1.210
1.188
1.150
1.120
1.500
1.482
1.460
1.438
1.400
1.370
1.342
1.750
1.732
1.710
1.688
1.650
1.620
1.592
2.125
2.107
2.085
2.063
2.025
1.995
1.967

1.840
1.960
2.104
2.245
2.483
2.665
2.175
2.318
2.492
2.662
2.951
3.173
3.377
2.509
2.677
2.880
3.080
3.419
3.682
3.923
3.011
3.215
3.462
3.706
4.122
4.445
4.742

TUBE LOAD BODY


(Lbs.)

INTERNAL
PRESSURE (psi)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. Ibs.)

INTERNAL
CAPACITY
per 1000 ft.

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

W/ MIN.
WALL

INTERNAL
MIN

YIELD

ULTIMATE

GALLONS

BARRELS

59,400
63,300
67,900
72,500
80,100
86,000
70,200
74,800
80,400
85,900
95,200
102,400
109,000
81,000
86,400
93,000
99,400
110,400
118,800
126,600
97,200
103,800
111,700
119,600
133,000
143,500
153,000

62,100
66,100
71,000
75,700
83,800
89,900
73,400
78,200
84,100
89,800
99,600
107,100
113,900
84,700
90,300
97,200
103,900
115,400
124,200
132,400
101,600
108,500
116,800
125,100
139,100
150,000
160,000

15,600
16,600
17,800
19,100
21,300
22,900
13,400
14,300
15,400
16,500
18,500
19,800
21,400
11,800
12,500
13,500
14,400
16,200
17,500
18,800
9,900
10,600
11,400
12,200
13,800
14,800
16,000

17,300
18,400
19,800
21,200
23,700
27,300
14,900
15,900
17,100
18,300
20,500
22,000
23,800
13,100
13,900
15,000
16,100
18,600
19,400
20,900
11,000
11,800
12,700
13,600
15,300
16,400
17,800

0.520
0.552
0.590
0.629
0.699
0.746
0.614
0.652
0.699
0.745
0.831
0.888
0.953
0.709
0.753
0.807
0.861
0.962
1.029
1.106
0.850
0.904
0.970
1.035
1.158
1.241
1.335

1.247
1.215
1.177
1.139
1.068
1.021
1.791
1.753
1.706
1.660
1.575
1.517
1.453
2.343
2.389
2.334
2.280
2.180
2.112
2.036
3.280
3.527
3.460
3.395
3.272
3.189
3.095

1,760
1,847
1,951
2,050
2,225
2,336
2,481
2,609
2,764
2,913
3,180
3,351
3,536
3,326
3,505
3,721
3,930
4,308
4,552
4,819
4,827
5,096
5,425
5,744
6,325
6,704
7,124

1,900
2,008
2,134
2,257
2,478
2,622
2,654
2,804
2,987
3,165
3,490
3,702
3,938
3,529
3,733
3,982
4,226
4,675
4,970
5,299
5,074
5,375
5,745
6,107
6,777
7,221
7,720

63.75
61.93
59.74
57.58
53.96
51.18
91.80
89.61
86.97
84.37
79.97
76.58
73.48
124.95
122.39
119.30
116.25
111.08
107.08
103.41
184.24
181.13
177.37
173.64
167.31
162.38
157.86

1.52
1.47
1.42
1.37
1.28
1.22
2.19
2.13
2.07
2.01
1.90
1.82
1.75
2.97
2.91
2.84
2.77
2.64
2.55
2.46
4.39
4.31
4.22
4.13
3.98
3.87
3.76

*Selected coiled tubing data


(110 Kpsi Min. Yield Strength; 115 Kpsi Min. Tensile Strength; 22 % Min. Elongation; Loads calculated using nom. wall)

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS
91.80
91.80
91.80
91.80
91.80
91.80
124.95
124.95
124.95
124.95
124.95
124.95
124.95
163.20
163.20
163.20
163.20
163.20
163.20
163.20
230.14
230.14
230.14
230.14
230.14
230.14
230.14

BARRELS
2.19
2.19
2.19
2.19
2.19
2.19
2.97
2.97
2.97
2.97
2.97
2.97
2.97
3.89
3.89
3.89
3.89
3.89
3.89
3.89
5.48
5.48
5.48
5.48
5.48
5.48
5.48

Test pressure value equals 90% of internal yield pressure rating. Maximum working pressure is a function of tube condition and is determined
by user. All data is for new tubing at minimum strength. * Available as continuously milled tubing (CM) or conventional butt-welded tubing
sections (W). See individual size sheets for additional wall thicknesses. 2-5/8", 2-7/8", and other sizes not shown are also available.

HS-110 GRADE* METRIC VALUES


DIMENSIONS
(mm)

NOMINAL
WEIGHT
Kg/m

O.D.
SPECIFIED

O.D.
(inches)

WALL
SPECIFIED

WALL
(inches)

WALL
MINIMUM

I.D.
CALCULATED

38.1

1.500

44.5

1.750

50.8

2.000

60.3

2.375

3.18
3.40
3.68
3.96
4.45
3.18
3.40
3.68
3.96
4.45
4.83
5.18
3.18
3.40
3.68
3.96
4.45
4.83
5.18
3.18
3.40
3.68
3.96
4.45
4.83
5.18

0.125
0.134
0.145
0.156
0.175
0.125
0.134
0.145
0.156
0.175
0.190
0.204
0.125
0.134
0.145
0.156
0.175
0.190
0.204
0.125
0.134
0.145
0.156
0.175
0.190
0.204

3.05
3.25
3.51
3.76
4.24
3.05
3.25
3.51
3.76
4.24
4.57
4.95
3.05
3.25
3.51
3.76
4.24
4.57
4.95
3.05
3.25
3.51
3.76
4.24
4.57
4.95

31.8
31.3
30.7
30.2
29.2
38.1
37.6
37.1
36.5
35.6
34.8
34.1
44.5
44.0
43.4
42.9
41.9
41.1
40.4
54.0
53.5
53.0
52.4
51.4
50.7
50.0

2.73
2.91
3.13
3.34
3.69
3.23
3.45
3.70
3.96
4.39
4.72
5.02
3.73
3.98
4.28
4.58
5.08
5.47
5.83
4.47
4.78
5.14
5.51
6.13
6.61
7.05

TUBE LOAD BODY


(Newtons)

INTERNAL
PRESSURE (kPa)

TUBING AREA
(sq. cm)

TORSIONAL
YIELD
(N-m)

INTERNAL
CAPACITY

EXTERNAL
DISPLACEMENT

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

W/ MIN.
WALL

INTERNAL
MIN

YIELD

ULTIMATE

LITERS / METER

LITERS / METER

168,100
179,100
192,200
205,100
226,800
198,700
211,800
227,700
243,200
269,600
289,900
308,500
229,300
244,600
263,100
281,400
312,400
336,400
358,400
275,100
293,800
316,300
338,600
376,600
406,100
433,200

192,100
204,600
219,700
234,400
259,200
227,100
242,100
260,200
278,000
308,100
331,400
352,600
262,000
279,500
300,700
321,600
357,000
384,500
409,600
314,400
335,700
361,500
387,000
430,400
464,100
495,100

67,200
72,800
78,200
83,600
93,700
57,900
62,600
67,400
72,200
81,000
86,900
93,800
50,800
55,000
59,200
63,400
71,300
76,600
82,700
42,900
46,400
50,000
53,600
60,300
64,900
70,100

74,700
80,900
86,900
92,900
104,100
64,300
69,600
74,900
80,200
90,000
96,600
104,200
56,400
61,100
65,800
70,400
79,200
85,100
91,900
47,700
51,600
55,600
59,600
67,000
72,100
77,900

3.35
3.56
3.81
4.06
4.51
3.96
4.21
4.51
4.81
5.36
5.73
6.15
4.57
4.86
5.21
5.56
6.20
6.64
7.13
5.48
5.83
6.26
6.68
7.47
8.01
8.62

8.05
7.84
7.59
7.35
6.89
11.55
11.31
11.01
10.71
10.16
9.79
9.37
15.70
15.41
15.06
14.71
14.06
13.63
13.13
23.10
22.75
22.32
21.90
21.11
20.57
19.97

1540
1590
1680
1770
1920
2160
2250
2380
2510
2740
2890
3050
2870
3020
3210
3390
3720
3930
4160
4170
4400
4680
4960
5460
5780
6150

1660
1730
1840
1950
2140
2290
2420
2580
2730
3010
3190
3400
3040
3220
3440
3650
4030
4290
4570
4350
4640
4960
5270
5850
6230
6660

0.79
0.77
0.74
0.72
0.67
1.14
1.11
1.08
1.05
0.99
0.95
0.91
1.55
1.52
1.48
1.44
1.38
1.33
1.28
2.29
2.25
2.20
2.16
2.08
2.02
1.96

1.14
1.14
1.14
1.14
1.14
1.55
1.55
1.55
1.55
1.55
1.55
1.55
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.86
2.86
2.86
2.86
2.86
2.86
2.86

*Selected coiled tubing data


(758 N/mm2 Min. Yield Strength; 793 N/mm2 Min. Tensile Strength; 22 % Min. Elongation; Loads calculated using nom. wall)

Test pressure value equals 90% of internal yield pressure rating. Maximum working pressure is a function of tube condition and is determined
by user. All data is for new tubing at minimum strength. * Available as continuously milled tubing (CM). 66.7mm and 73.0mm, and other
sizes not shown are also available.

Coiled Tubing Data 1.50" O.D.


HS-110 CM*
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

1.500

0.125
0.134
0.145
0.156
0.175
0.190

0.120
0.128
0.138
0.148
0.167
0.180

1.250
1.232
1.210
1.188
1.150
1.120

NOMINAL
WEIGHT
(lbs / ft)

1.840
1.960
2.104
2.245
2.483
2.665

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

59,400
63,300
67,900
72,500
80,100
86,000

62,100
66,100
71,000
75,700
83,800
89,900

15,300
16,600
17,800
19,100
21,300
22,900

17,000
18,400
19,800
21,200
23,700
27,300

HS-110 CM*
DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

1.500

0.120
0.128
0.138
0.148
0.167
0.180

0.512
0.552
0.590
0.629
0.699
0.746

1.255
1.215
1.177
1.139
1.068
1.021

1,738
1,847
1,951
2,050
2,225
2,336

1,877
2,008
2,134
2,257
2,478
2,622

63.75
61.93
59.74
57.58
53.96
51.18

1.52
1.47
1.42
1.37
1.28
1.22

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS

91.80
91.80
91.80
91.80
91.80
91.80

BARRELS

2.19
2.19
2.19
2.19
2.19
2.19

* Continuously milled tubing.

HS-110 CM

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 1.75" O.D.


HS-110 CM*
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

1.500

0.125
0.134
0.145
0.156
0.175
0.190
0.204

0.120
0.128
0.138
0.148
0.167
0.180
0.195

1.500
1.482
1.460
1.438
1.400
1.370
1.342

NOMINAL
WEIGHT
(lbs / ft)

2.175
2.318
2.492
2.662
2.951
3.173
3.377

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

70,200
74,800
80,400
85,900
95,200
102,400
109,000

73,400
78,200
84,100
89,800
99,600
107,100
113,900

13,200
14,300
15,400
16,500
18,500
19,800
21,400

14,700
15,900
17,100
18,300
20,500
22,000
23,800

HS-110 CM*
DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

1.500

0.120
0.128
0.138
0.148
0.167
0.180
0.195

0.605
0.652
0.699
0.745
0.831
0.888
0.953

1.800
1.753
1.706
1.660
1.575
1.517
1.453

2,448
2,609
2,764
2,913
3,180
3,351
3,536

2,616
2,804
2,987
3,165
3,490
3,702
3,938

91.80
89.61
86.97
84.37
79.97
76.58
73.48

BARRELS

2.19
2.13
2.07
2.01
1.90
1.82
1.75

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS

124.95
124.95
124.95
124.95
124.95
124.95
124.95

BARRELS

2.97
2.97
2.97
2.97
2.97
2.97
2.97

* Continuously milled tubing.

HS-110 CM

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 2.00" O.D.


HS-110 CM*
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

2.000

0.125
0.134
0.145
0.156
0.175
0.190
0.204

0.120
0.128
0.138
0.148
0.167
0.180
0.195

1.750
1.732
1.710
1.688
1.650
1.620
1.592

NOMINAL
WEIGHT
(lbs / ft)

2.509
2.677
2.880
3.080
3.419
3.682
3.923

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

81,000
86,400
93,000
99,400
110,400
118,800
126,600

84,700
90,300
97,200
103,900
115,400
124,200
132,400

11,600
12,500
13,500
14,500
16,200
17,500
18,800

12,900
13,900
15,000
16,100
18,000
19,400
20,900

HS-110 CM*
DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

2.000

0.120
0.128
0.138
0.148
0.167
0.180
0.195

0.698
0.753
0.807
0.861
0.962
1.029
1.106

2.444
2.389
2.334
2.280
2.180
2.112
2.036

3,280
3,505
3,721
3,930
4,308
4,552
4,819

3,477
3,733
3,982
4,226
4,675
4,970
5,299

124.95
122.39
119.30
116.25
111.08
107.08
103.41

2.97
2.91
2.84
2.77
2.64
2.55
2.46

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS

163.20
163.20
163.20
163.20
163.20
163.20
163.20

BARRELS

3.89
3.89
3.89
3.89
3.89
3.89
3.89

* Continuously milled tubing.

HS-110 CM

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 2.375" O.D.


HS-110 CM*
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

2.375

0.125
0.134
0.145
0.156
0.175
0.190
0.204

0.120
0.128
0.138
0.148
0.167
0.180
0.195

2.125
2.107
2.085
2.063
2.025
1.995
1.967

NOMINAL
WEIGHT
(lbs / ft)

3.011
3.215
3.462
3.706
4.122
4.445
4.742

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

97,200
103,800
111,700
119,600
133,000
143,500
153,000

101,600
108,500
116,800
125,100
139,100
150,000
160,000

9,800
10,600
11,400
12,200
13,800
14,800
16,000

10,900
11,800
12,700
13,600
15,300
16,400
17,800

HS-110 CM*
DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

EXTERNAL
DISPLACEMENT
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

GALLONS

BARRELS

2.375

0.120
0.128
0.138
0.148
0.167
0.180
0.195

0.837
0.904
0.970
1.035
1.158
1.241
1.335

3.593
3.527
3.460
3.395
3.272
3.189
3.095

4,759
5,096
5,425
5,744
6,325
6,704
7,124

4,999
5,375
5,745
6,107
6,777
7,221
7,720

184.24
181.13
177.37
173.64
167.31
162.38
157.86

4.39
4.31
4.22
4.13
3.98
3.87
3.76

230.14
230.14
230.14
230.14
230.14
230.14
230.14

5.48
5.48
5.48
5.48
5.48
5.48
5.48

* Continuously milled tubing.

HS-110 CM

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 2.625" O.D.


HS-110 CM*
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

2.625

0.156
0.175
0.190
0.204

0.148
0.167
0.180
0.195

2.313
2.275
2.245
2.217

NOMINAL
WEIGHT
(lbs / ft)

4.124
4.590
4.953
5.288

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

133,100
148,200
159,900
170,700

139,200
154,900
167,100
178,400

11,100
12,500
13,400
14,500

12,300
13,900
14,900
16,100

HS-110 CM*
DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

EXTERNAL
DISPLACEMENT
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

GALLONS

BARRELS

2.625

0.148
0.167
0.180
0.195

1.152
1.290
1.383
1.489

4.260
4.122
4.029
3.923

7,144
7,886
8,372
8,913

7,553
8,396
8,956
9,587

218.28
211.17
205.63
200.54

5.20
5.03
4.90
4.77

281.14
281.14
281.14
281.14

6.69
6.69
6.69
6.69

* Continuously milled tubing.

HS-110 CM

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.