Sie sind auf Seite 1von 9

Electronic Total Station

Quick Reference Guide


PSF software For R-300 series

PENTAX Precision Co., Ltd.


INSTRUCTION MANUALS
Quick Reference Guide is intended to provide a quick reference in the field. For ease of use in the field, the following Quick Reference Guide booklets are provided in the carrying case. 1. Basic procedure 2. PowerTopoLite for R-300 series, Operating procedure 3. PSF software for R-300 series, Operating procedure The complete instruction manuals are contained on the CD that is attached to each R-300.

Operating Procedure
R-322N, R-323N, R-325N, R-335N, R-315N, R-322, R-323, R-325, R-335, R-315, R-326

PRECAUTIONS REGARDING SAFETY


Before using this product, be sure that you have thoroughly read and understood the instruction manual that is included on the attached CR-R to ensure proper operation.

Draft Ver. 02.10.19 yk

OPERATIONAL PROCEDURE
The operational procedure in this guide is described based on the default software parameter settings (preferences). Changing preferences may cause a different operational procedure. For further detail of preferences, please refer to the instruction manual of PCS300 software. This guide uses the symbol " xN " as an expression of repeating times of key operation. For example, " ESC x2 " means that [ESC] key is pressed two times.

1. Starting a Special Function


Laser

Note: To input a new station number, press [ENT] at the first "0000" line, and input the number, and then a point description, X, Y, and Z coordinate:
MODE S. Func

ESC

or

MODE A screen

F5

F1

Special Function menu


STORE

move cursor to the input item


F2

SELECT

F5

input the value

ENT

Special functions are also accessible by 007 code:


MODE A screen 0 0 7

input 007 command No.


COORD.STAKE OUT menu

Special Function sub-menu

Input the Instrument height:


INSTRUMENT HEIGHT INPUT screen

saves the input data in memory. -2(with the cursor at "6.INST.H:")


SELECT

example:
MODE A screen 0 0 7 1 0 9

F5

input the value

ENT x2

BACKSIGHT SELECTION screen

Note: 007 commands are listed in the table below. Special functions are also accessible by the HELP MENU. For HELP MENU procedure, refer to "2. Changing Instrument Settings" of the Quick reference Guide, Basic Procedures for R-300. PCS300 software adds the following functions to the HELP MENU Instrument Setting. .

Select the Backsight point:


BACKSIGHT SELECTION screen

ENT

select the job by

ENT
F1 F4

x2
FORESIGHT NUMBER LIST screen

aim the backsight point

ENT

Menu No. 24. 25. 26. 27. 28. 29. 30. 31. 32.

Functions Distance Stakeout RDM Coordinates Offset Shots Coord. Stakeout REM Resection Data Storage Memory Management

"007" command No. 101 103 104 105 109 112 113 119 200

Note: To input new point information, press [ENT] key at the first "0000" line, and input the number, and then a point description, X, Y, and Z coordinate. F2 [STORE] key saves the input data in memory. Orientation can be also made by azimuth angle input from the next ANGLE COMPARE screen, instead of selecting the backsight point. Proceed to the next step:

Select a foresight and stakeout:


FORESIGHT NUMBER LIST screen

select the job by

ENT
F1
SELECT

F4

(with the cursor at "6.PRISM H:")

F5

input the value

ENT
ANGLE COMPARE screen

2. COORD. STAKEOUT
To start Coord. Stakeout:
Special Function menu F4

007-109
ENT
COORD.STAKE OUT menu

x2

To define the stakeout direction:


ANGLE COMPARE screen

turn the instrument until DEVIATE angle becomes 0

ANG/DIST

F4 DIST. COMPARE screen

Select the Job:


COORD.STAKE OUT menu

ENT

select the job by

ENT
F1 F4

COORD.STAKE OUT menu

Note: To set the azimuth angle, Note: To create a new job, press [ENT] at the first empty line and input a job name. aim at the backsight point
H.INPUT

F2

input the azimuth angle

ENT

Select the station:


COORD.STAKE OUT menu

To define the stakeout distance:


ENT
F4

select the station number by

F1

F4 INSTRUMENT HEIGHT INPUT screen

DIST. COMPARE screen

TRACK

F2

move the target until H.Dist.DEVIAT becomes 0


FORESIGHT NUMBER LIST screen

ENT

ENT

select next point

To measure the second point:


Note: F3 [TARGT] switches the EDM mode to Prism -> Reflecting sheet -> Reflecterless -> Prism -> , each time it is pressed. After TRACK measurement, the target position can be measured accurately by using F1 [MEAS].
RDM POINT screen

aim at the second point


MEAS

PRISM H

F3

input the prism height


RDM Ref.-P screen

ENT

ENT

F1

RDM POINT screen

To quit:
FORESIGHT NUMBER LIST screen

ESC x2

Special Function sub-menu

Note: In the RDM Ref.-P screen, the distance and the grade % from the reference point to the first point are displayed.

To measure the third point:

3. DISTANCE STAKEOUT
Special Function menu F4

007-101
DIST. STAKE OUT screen

RDM POINT screen


MEAS

aim at the third point ENT


RDM Ref.-P screen

PRISM H

F3 DISP F4

input the prism height


RDM P-P screen

X7

ENT

ENT

F1

RDM POINT screen

proceed to the next point

To input the distance:


DIST. STAKE OUT screen

select H.dist, S.dist or V.dist by

F3

SELECT

F4

F5

Note: In the RDM P-P screen, the distance and the grade % from the previous point are displayed.
DIST. COMPARE screen

input the value

ENT

x2

To quit:
RDM POINT screen

To define the stakeout distance:


DIST. COMPARE screen
TRACK

ESC x2

Special Function sub-menu

-4-

F2

move the target until H.Dist.DEVIAT becomes 0

Note: F3 [TARGT] switches the EDM mode to Prism -> Reflecting sheet -> Reflecterless -> Prism -> , each time it is pressed. After TRACK measurement, the target position can be measured accurately by using F1 [MEAS].

5. COORDINATES
Special Function menu

007-104
ENT
COORDINATES menu

F4

To quit:
DIST. COMPARE screen

Select the Job:


ESC
Special Function sub-menu COORDINATES menu

ENT

select the job by

ENT
F1 F4

COORDINATES menu

Note: To create a new job, press [ENT] at the first empty line and input a job name.

4. RDM
Special Function menu F4

007-103
X5
ENT
RDM Ref. screen

Select the station:


COORDINATES menu

ENT
F4

select the station number by

F1

F4 BACKSIGHT SELECTION screen

To measure the reference point:


RDM Ref. screen
PRISM H

ENT
MEAS

F3

input the prism height

ENT

F1

RDM POINT screen

Note: F2 [TARGT] switches the EDM mode to Prism -> Reflecting sheet -> Reflecterless -> Prism -> , each time it is pressed. F4 [DIST] is a toggle switch to change the distance display between H.dist, S.dist and V.Dist.

Note: To input a new station number, press [ENT] at the first "0000" line, and input the number, and then a point description, X, Y, and Z coordinate, and the instrument height:
STATION COORDINATES INPUT screen

move cursor to the input item

SELECT

F5

input the value

press ENT at the last item F2 [STORE] saves the input data in memory.

ENT

BACKSIGHT SELECTION screen

input the instrument height


Note: To input a new station number, press [ENT] at the first "0000" line, and input the number, and then a point description, X, Y, and Z coordinate, and the instrument height:

Select the Backsight point:


BACKJSIGHT SELECTION screen

ENT

select the point number by

ENT
F1 F4

STATION COORDINATES INPUT screen

move cursor to the input item ENT

SELECT

F5

input the value


BACKJSIGHT SELECTION screen

aim at the backsight

ENTx2

SURVEY screen

press ENT at the last item

F2 [STORE] saves the input data in memory. Note: To input new point information, press [ENT] at the first "0000" line, and input the number, and then a point description, X, Y, and Z coordinate. F2 [STORE] saves the input data in memory. Orientation can be also made by azimuth angle input from the next SURVEY screen, instead of selecting the backsight point. Proceed to the next step:

Select the Backsight point:


BACKSIGHT SELECTION screen

ENT

select the job by

ENT
F1 F4

aim at the backsight

ENT

SURVEY screen

To measure:
SURVEY screen
MEAS

F1

DISP F4

confirm the coordinates

POINT F3

input or edit the point number, Description and Prism H.


STORE F2

ENT

Note: To input new point information, press [ENT] at the first "0000" line, and input the number, and then a point description, X, Y, and Z coordinate. F2 [STORE] saves the input data in memory. Orientation can be also made by azimuth angle input from the next SURVEY screen, instead of selecting the backsight point. Proceed to the next step:

next measurement

To measure:
SURVEY screen
MEAS

Note: The point number is automatically incremented or decremented for quick survey. By pressing F5 [1/2], other functions are displayed: F2 [H.INPUT] Input the orientation angle F3 [0 SET] Set the orientation angle to 0 F4 [HOLD] Hold the displayed horizontal angle. F5 [2/2] Toggle switch to change the functions

F1

PRISM F3

input the prism height

ENT

ENT

OFFSET MEASURE screen

To quit:
SURVEY screen or COORDINATES screen

Note: By pressing F5 [1/2], another functions are displayed: F2 [H.INPUT] Input the orientation angle F3 [0 SET] Set the orientation angle to 0 F4 [HOLD] Hold the displayed horizontal angle F5 [2/2] Toggle switch to change the functions

ESC x2

Special Function sub-menu

To input the offsets:


OFFSET MEASURE screen

ENT

select the offset item by


-6-

F3

SELECT

F4

F5

6. OFFSET SHOTS
Special Function menu F4

007-105
ENT
OFFSET SHOTS menu

input the offset value

ENT

OFFSET RESULT screen

X3

To save the result:


ENT
OFFSET RESULT screen OFFSET SHOTS menu
POINT No

Select the Job:


OFFSET SHOTS menu

ENT

F3

edit the point number and description.

ENT
STORE F2 SURVEY screen

select the job by

F1

F4

Note: To create a new job, press [ENT] at the first empty line and input a job name.

To quit:
SURVEY screen or COORDINATES screen

Select the station:


OFFSET SHOTS menu

ENT
F4

select the station number by


ENT

ESC x2

Special Function sub-menu

F1

F4 BACKJSIGHT SELECTION screen

7. REM
Special Function menu F4

007-112
X6
ENT
REM screen

F2 [STORE] saves the input data in memory.

To measure the reference point A:


A SURVEY screen
MEAS

ENT

F1

B POINT NUMBER LIST screen

To measure the reference height:


REM screen
PRISM H

F3

input the prism height

ENT

aim at the target

MEAS

Note: Change the EDM mode by using F2 [TARGET] if necessary.

F1

Select and measure the reference point B by the same procedure as for the point A.
B POINT NUMBER LIST screen

To execute Remote Elevation Measurement:


ENT turn the telescope and aim at an object confirm REM value

select the job by

ENT
F1
SELECT

F4

To quit:
REM screen

(with the cursor at "6.PRISM H:") ESC x2


Special Function sub-menu

F5

input the value

ENT

X2
B SURVEY screen

B SURVEY screen

MEAS

ENT

F1

STATION POINT screen

8. RESECTION
Special Function menu F4

007-113
X4
ENT
RESECTION menu

To save the result


STATION POINT screen
STORE

F2

RESECTION menu

Select the Job:


RESECTION menu

Note: If you do not need the result saved, just press [ENT] in the STATION POINT screen. ENT

select the job by

ENT
F1 F4

RESECTION menu

To quit:
RESECTION menu

ESC

Note: To create a new job, press [ENT] at the first empty line and input a job name.

Special Function sub-menu

To input the station point information:


RESECTION menu

ENT
F4

9. DATA STORAGE
SELECT

007-119
DATA STORAGE menu

move cursor to the input item input the value and ENT

F5

ENT

A POINT NUMBER LIST screen

Special Function menu

ENT

Select the Job:


DATA STORAGE menu

To select the reference point A:


A POINT NUMBER LIST screen

ENT

select the job by

ENT
F1
SELECT

select the job by

ENT
F1 F4

DATA STORAGE menu

F4

(with the cursor at "6.PRISM H:")

F5

input the value

ENT

X2
A SURVEY screen

Note: To create a new job, press [ENT] at the first empty line and input a job name. After creating a new job, the program automatically proceeds to STATION INPUT screen.

Input the station information:


DATA STORAGE menu
SELECT

ENT
F4

SELECT

F5

input the station number ENT


SELECT

ENT

Note: To input a new station number, press [ENT] at the first "0000" line, and input the number, and then a point description, X, Y, and Z coordinate, and the instrument height:
STATION COORDINATES INPUT screen

F5

input the point description input the instrument height

F5

ENT

STORE

SURVEY screen

move cursor to the input item ENT

SELECT

F5

input the value


BACKJSIGHT SELECTION screen

F2

press ENT at the last item

Note: Target constant, ppm value, and atmospheric temperature and pressure are automatically applied. If you require measuring and inputting manually, change the instrument settings. Refer to the instruction manual.

To input the point information and measure:


SURVEY screen POINT F3
MEAS

POINT NUMBER INPUT screen

select the point by

ENT
F1 F4
SELECT

POINT EDIT screen

input the point number, description, and the prism height -8F1 DISP F3

move the cursor and press

-9F5

edit the data and press


ENT

ENT

ENT

MEAS

STORE

F1

F2

SURVEY screen

Note: In this program, there is no separate procedure to measure the backsight point, as the first data saved after the station information is usually considered as that of the backsight point, depending on the post processing program. For the orientation of the horizontal angle, use the function keys on the second function page by pressing F5 [1/2].

POINT NUMBER to over write INPUT screen Note: New survey data cannot be created through keyboard input. The survey data that is automatically obtained by the instrument cannot be edited.

11. MEMORY MANAGEMENT


Special Function menu

007-200

ENT
F2

MEMORY MANAGER menu

To input or edit coordinate data:


MEMORY MANAGER menu F4

X2

ENT

JOB NAME INPUT screen

Select the Job:


JOB NAME INPUT screen

ENT

select the job by

ENT
F1 F4

POINT NUMBER INPUT screen

Note: To create a new job, press [ENT] at the first empty line and input a job name.

Point selection:
POINT NUMBER INPUT screen

select the point by

ENT
F1 F4
SELECT

COORDINATE EDIT screen

move the cursor and press

F5

edit the data and press


ENT to over write

ENT

POINT NUMBER INPUT screen

Note: To input new point information, press [ENT] at the first "0000" line, and input the number, and then a point description, X, Y, and Z coordinate.

To input or edit survey data:


MEMORY MANAGER menu F4

X5

ENT

JOB NAME INPUT screen

Select the Job:


JOB NAME INPUT screen

ENT

select the job by

ENT
F1 F4

POINT NUMBER INPUT screen

Note: To create a new job, press [ENT] at the first empty line and input a job name. Point selection:

PENTAX Precision Co., Ltd.


2-5-2, Higashi-Oizumi, Nerima-ku, Tokyo, 178-8555, Japan Tel: +81-3-5905-1222 Fax:+81-3-5905-1225

Member symbol of the Japan Surveying Instruments Manufacturers Association representing the high quality surveying products.

09.2002 First Edition

: : : : : : : : : : : : : : : : :

Quick_Guide_PCS-1019.doc G:0_R-300 C:WINDOWSApplication R-300

DataMicrosoftTemplatesNormal.dot

02/10/19 10:35 5 02/10/30 12:41 Kata 443 02/10/30 12:48 8 1,574 () 7,716 ()