TWCAT Driver Version 1.

03
Doc. Revision D January 6, 2005
Page 1/16
TWCAT Communication Driver
Driver for TCP/IP Communication
with TWINCAT PLC Using TwinCAT ADS Library

Contents
INTRODUCTION....................................................................................................................................................... 2
GENERAL INFORMATION....................................................................................................................................... 3
DEVICE CHARACTERISTICS .................................................................................................................................... 3
LINK CHARACTERISTICS......................................................................................................................................... 3
DRIVER CHARACTERISTICS .................................................................................................................................... 3
CONFORMANCE TESTING....................................................................................................................................... 4
INSTALLING THE DRIVER...................................................................................................................................... 5
CONFIGURING THE DRIVER.................................................................................................................................. 6
SETTING THE COMMUNICATION PARAMETERS......................................................................................................... 6
CONFIGURING THE DRIVER WORKSHEETS .............................................................................................................. 7
EXECUTING THE DRIVER..................................................................................................................................... 12
TROUBLESHOOTING............................................................................................................................................ 13
SAMPLE APPLICATION........................................................................................................................................ 15
REVISION HISTORY............................................................................................................................................... 16

TWCAT Driver Version 1.03
Doc. Revision D January 6, 2005
Page 2/16
Introduction
The TWCAT driver enables communication between the Studio system and TwinCAT PLC using the TwinCAT
ADS Interface PLC over TCP/IP, according to the specifications discussed in this document.
This document was designed to help you install, configure and execute the TWCAT driver to enable
communication with these devices. The information in this document is organized as follows:
Introduction: Provides an overview of the TWCAT driver documentation.
General Information: Provides information needed to identify all the required components (hardware and
software) used to implement communication between Studio and the TWCAT driver.
Installing the Driver: Explains how to install the TWCAT driver.
Configuring the Driver: Explains how to configure the TWCAT driver.
Executing the Driver: Explains how to execute the driver to verify that you installed and configured the
driver correctly.
Troubleshooting: Lists the most common error codes for this protocol and explains how to fix these errors.
Sample Application: Explains how to use a sample application to test the TWCAT driver configuration.
Revision History: Provides a log of all modifications made to the driver and the documentation.

Notes:
This document assumes that you have read the Development Environment chapter in the Studio
Technical Reference Manual.
This document also assumes that you are familiar with the Windows NT/2000/XP environment.
If you are unfamiliar with Windows NT/2000/XP, we suggest using the Help feature (available from the
Windows desktop Start menu) as you work through this guide.

TWCAT Driver Version 1.03
Doc. Revision D January 6, 2005
Page 3/16
General Information
This chapter explains how to identify all the hardware and software components used to implement
communication between the Studio TWCAT driver and the TwinCAT PLC.
The information is organized into the following sections:
Device Characteristics
Link Characteristics
Driver Characteristics
Device Characteristics
To establish communication, you must use devices with the following specifications:
Manufacturer: Beckhoff
Compatible Equipment: Beckhoff TwinCAT Software
Programmer Software: Beckhoff TwinCAT (System Manager and PLC Control)
Link Characteristics
To establish communication, you must use links with the following specifications:
Device Communication Port: TwinCAT TCP/IP Port
Physical Protocol: Ethernet/TCP/IP
Logic Protocol: Proprietary
Device Runtime Software: TwinCAT Software
Third Party Library: TwinCAT ADS Interface PLC Software (tcAdsDll.dll or tcAdsDllCE.dll)
Specific PC Board: Any TCP/IP Adapter (Ethernet Board)
Driver Characteristics
The TWCAT driver is composed of the following files:
TWCAT.INI: Internal driver file. You must not modify this file.
TWCAT.MSG: Internal driver file containing error messages for each error code. You must not modify this file.
TWCAT.PDF: Document providing detailed information about the TWCAT driver.
TWCAT.DLL: Compiled driver.



Notes:
All of the preceding files are installed in the /DRV subdirectory of the Studio installation directory.
You must use Adobe Acrobat

Reader (provided on the Studio installation CD-ROM) to view the


TWCAT.PDF document.

You can use the TWCAT driver on the following operating systems:
Windows 9x
Windows 2000
Windows NT
Windows CE
For a list of the operating systems used for conformance testing, see Conformance Testing on page 4.
TWCAT Driver Version 1.03
Doc. Revision D January 6, 2005
Page 4/16
The TWCAT driver supports the following flair registers:

Register Type Length Write Read Bit Integer Float DWord
%M 1 Byte
%MX 1 Byte
%Q 1 Byte
%QX 1 Byte
%I 1 Byte
%IX 1 Byte
NAME
REFRESH

Conformance Testing
The following hardware/software was used for conformance testing:
Driver Configuration: PLC Program Machine
Cable: Ethernet Cable
Driver
Version
Studio
Version
Operating System
(Development)
Operating System
(Target)
Equipment
1.02 6.0
Windows XP +
Service Pack 2
Windows XP +
Service Pack 2
Windows CE
v4.2
Equipment: Beckhoff TwinCAT PLC


TWCAT Driver Version 1.03
Doc. Revision D January 6, 2005
Page 5/16
Installing the Driver
When you install Studio version 5.1 or higher, all of the communication drivers are installed automatically.
You must select the driver that is appropriate for the application you are using.
Perform the following steps to select the driver from within the application:
1. Open Studio from the Start menu.
2. From the Studio main menu bar, select File Open Project to open your application.
3. Select Insert Driver from the main menu bar to open the Communication Drivers dialog.
4. Select the TWCAT driver from the Available Drivers list, and then click the Select button:

Communication Drivers Dialog
5. When the TWCAT driver displays in the Selected Drivers list, click the OK button to close the dialog.


Note:
It is necessary to install the TwinCAT ADS Interface PLC software on your computer to enable
communication between the host and the device.



Caution:
For safety reasons, you must use special precautions when installing the physical hardware. Consult the
hardware manufacturers documentation for specific instructions in this area.


TWCAT Driver Version 1.03
Doc. Revision D January 6, 2005
Page 6/16
Configuring the Driver
After opening Studio and selecting the TWCAT driver, you must configure the driver. Configuring the TWCAT
driver is done in two parts:
Specifying communication parameters
Defining tags and controls in the MAIN and STANDARD DRIVER SHEETs (or Communication tables)
Worksheets are divided into two sections, a Header and a Body. The fields contained in these two sections
are standard for all communications drivers except the Station, Header and Address fields, which are driver-
specific. This document explains how to configure the Station, Header and Address fields only.


Note:
For a detailed description of the Studio MAIN and STANDARD DRIVER SHEETs, and information about
configuring the standard fields, review the products Technical Reference Manual.

Setting the Communication Parameters
Use the following steps to configure the communication parameters, which are valid for all Driver worksheets
configured in the system:
1. From the Studio development environment, select the Comm tab located below the Workspace pane.
2. Click on the Drivers folder in the Workspace pane to expand the folder.
3. Right-click on the TWCAT subfolder and when the pop-up menu displays, select the Settings option:

Select Settings from the Pop-Up Menu
The TWCAT: Communication Parameters dialog displays:

Communication Parameters Dialog
TWCAT Driver Version 1.03
Doc. Revision D January 6, 2005
Page 7/16
4. Specify the parameters as noted in the following table:

Parameters Default Values Valid Values Description
Station 0 0 Not used for this driver

5. Click the Advanced button on the Communication Parameters dialog to open the Advanced Settings dialog and
configure the necessary settings.

Notes:
Do not change any of the other Advanced parameters at this time. You can consult the Studio
Technical Reference Manual for information about configuring these parameters for future reference.
Generally, you must change the Advanced parameter settings if you are using a DCE (Data
Communication Equipment) converter (232/485 for example), modem and so forth between the
PC, the driver and the host. You must be familiar with the DCE specifications before adjusting these
configuration parameters.

Configuring the Driver Worksheets
This section explains how to configure the MAIN and STANDARD DRIVER SHEETs (or Communication tables) to
associate application tags with the device addresses. You can configure multiple Driver worksheets each of
which is divided into a Header section and Body section.
Configuring the MAIN DRIVER SHEET
When you add the TWCAT driver to your application, Studio automatically adds a MAIN DRIVER SHEET to the
driver folder, as shown in the following figure:

MAIN DRIVER SHEET
TWCAT Driver Version 1.03
Doc. Revision D January 6, 2005
Page 8/16
You use this worksheet (similar to the following figure) to associate Studio tags to addresses in the PLC:

MAIN DRIVER SHEET


Note:
Most of the MAIN DRIVER SHEET parameters are standard for all drivers, and are not discussed in this
document. Instructions for configuring these standard parameters are provided in the Studio Technical
Reference Manual.

Use the following information to configure the Station and Address parameters specific to this driver:
Station: Type the PLC AmsNetID Address (ID number) and the Runtime number or station port.
<AmsNetID>:<Runtime or Port Number> (for example: 192.168.1.72.1.1:1 or 192.168.1.72.1.1:301)
Where:
- AmsNetID: AmsNet ID of the PLC.
- Runtime: Runtime number of PLC program.
- Port Number: PLC/NC/IO port used to do the communication.

I/O Address: Type the address of each register in the PLC using the following syntax (for Input and Outputs):
<Type>[<StartAddress>:<Datatype>]<Offset>.[Bit] (for example, %Q0:W0.0, %QX0.0,
.engine)
Where:
Type: Register type (%M, %MX, %Q, %QX, %I, %IX, <Variable Name>). When the <Variable Name> is
configured, the Datatype is populated automatically. The variables declared in the Global Variables need
to use the prefix . (for example, .engine, .speed).
StartAddress (optional): Start address of the devices register. This value must be configured only with the
%Q, %I and %M operands. When this value is configured, the Datatype must be configured too.
Datatype (optional): Format of data B (byte), W (word), D (double word) and F (float). It must be used only
with the %Q, %I and %M operands. When the operand is %QX, %MX or %IX, the data type is bit by default.
Offset: This value is the offset of the StartAddress. When the StartAddress is not configured, the value is 0
(zero) by default.
TWCAT Driver Version 1.03
Doc. Revision D January 6, 2005
Page 9/16
Bit (optional): Indicates the bit number to be read from/written to the device.
Configuring the STANDARD DRIVER SHEET
Use the following steps to create a new STANDARD DRIVER SHEET:
1. From the Studio development environment, select the Comm tab, located below the Workspace pane.
2. In the Workspace pane, expand the Drivers folder and right-click the TWCAT subfolder.
3. When the pop-up menu displays, select the Insert option:

Inserting a New Worksheet


Note:
To optimize communication and ensure better system performance, you must tie the tags in different
Driver worksheets to the events that trigger communication between each tag group and the period in
which each tag group must be read or written. Also, we recommend configuring the communication
addresses in sequential blocks to improve performance.

The STANDARD DRIVER SHEET displays (similar to the following figure):

STANDARD DRIVER SHEET
TWCAT Driver Version 1.03
Doc. Revision D January 6, 2005
Page 10/16
In general, all parameters on the Driver worksheet (except the Station, Header and Address fields) are standard
for all communication drivers, but they will not be discussed in this document. For detailed information about
configuring the standard parameters, consult the Studio Technical Reference Manual.
4. Use the following information to complete the Station, Header and Address fields on this worksheet.
Station: Type the PLC AmsNetID Address (ID number) and the Runtime or Port number.
<AmsNetID>:<Runtime or Port Number> (for example: 192.168.1.72.1.1:1 or 192.168.1.72.1.1:301)
Where:
- AmsNetID: AmsNet ID of the PLC.
- Runtime: Runtime number of PLC program.
- Port Number: PLC/NC/IO port used to do the communication.
Header field: Use the information in the following table to define the type of variables that will be read from
or written to the device and a reference to the initial address (default value is %M:0).
These variables must comply with the following syntax:
<Type>:<AddressReference> (for example: %QX:0).
Where:
* Type is the register type (%M, %MX, %Q, %QX, %I, %IX, NAME, or REFRESH).
* AddressReference is the initial address (reference) of the configured type.
After you edit the Header field, Studio checks the syntax to determine if it is valid. If the syntax is incorrect,
Studio automatically inserts the default value in the Header field.
Also, you can type a tag string in brackets {Tag} into the Header field, but you must be certain that the
tags value is correct and that you are using the correct syntax or you will get an invalid Header error.
The following table lists all of the data types and address ranges that are valid for the TWCAT driver.

Header Field Information
Data
Types
Sample
Syntax
Valid Range of Initial
Addresses per Worksheet
Comments
%M %M:0 Varies according to the equipment Memory: Read and write data value in the memory area. The data
type can be BYTE, WORD, DWORD or FLOAT.
%MX %MX:0 Varies according to the equipment Memory: Read and write data value in the memory area. The data
type can be only BIT.
%Q %Q:0 Varies according to the equipment Output: Read and write data value in the outputs. The data type can
be BYTE, WORD, DWORD or FLOAT.
%QX %QX:0 Varies according to the equipment Output: Read and write data value in the output. The data type can
be only BIT.
%I %I:0 Varies according to the equipment Input: Read and write data value in the inputs. The data type can be
BYTE, WORD, DWORD or FLOAT.
%IX %IX:0 Varies according to the equipment Input: Read and write data value in the input. The data type can be
only BIT.
NAME NAME Varies according to the equipment Read and write data value using the variable name in the address.
The data type will be discovered automatically.
REFRESH REFRESH Varies according to the equipment Refresh the driver internal list with variable information configured in
the TwinCAT PLC.

TWCAT Driver Version 1.03
Doc. Revision D January 6, 2005
Page 11/16
Address field: Use the information in the next table to associate each tag to its respective device address.
Type the tag from your application database into the Tag Name column. This tag will receive values from or
send values to an address on the device. The address must comply with the following syntax:
<Type><AddressOffset>.[Bit] (for example: B10, W20.5, DW1, .engine).
Where:
Type Format of data B (byte), W (word), D (double word) and F (float). It must be used only with the
%Q, %I and %M operands. When the operand is %QX, %MX or %IX, the data type must be BYTE and
the Bit must be configured.
AddressOffset is a parameter added to the AddressReference parameter (configured in the Header field)
to compose the group address configured in the Header field.
Bit (optional parameter) is the bit number to be read from or written to the device. The bit value must
be configured with %QX, %MX or %IX operands. If it is not configured, the zero value will be get by
default.
Address Configuration Sample
Device Address Header Field Address Field
%QX0.0 %QX0 B0.0
%QX0.5 %QX0 B0.5
%QX1.0 %QX0 B1.0
%QX0.0 %Q0 B0.0
%Q0 (8 bits) %Q0 B0
%QX1.1 %Q0 W0.9
%M0 (Word) %M0 W0
%M5 (BYTE) %M0 B5
%M5 (BYTE) %M5 B0
%MX5.0 %MX0 B5.0
%IX10.7 %IX0 B10.7
%IX10.7 %I0 B10.7
%I10 and %I11 (16bits) %I W10
engine (Global Variable) NAME .engine
speed (Global Variable) NAME .speed
down (Global Variable) NAME .down
balance (main program) NAME MAIN.balance




Caution:
You must not configure a range of addresses or variable greater than the maximum block size (data buffer
length) supported by each PLC within the same worksheet. The maximum data buffer length for this driver is
128 addresses or variable name, per Standard Driver worksheet.

TWCAT Driver Version 1.03
Doc. Revision D January 6, 2005
Page 12/16
Executing the Driver
After adding the TWCAT driver to a project, Studio sets the project to execute the driver automatically when you
start the run-time environment.
To verify that the Driver Runtime task is enabled and will start correctly, perform the following steps:
1. Select Project Status from the main menu bar.
The Project Status dialog displays:

Project Status Dialog
2. Verify that the Driver Runtime task is set to Automatic.
If the setting is correct, click OK to close the dialog.
If the Driver Runtime task is set to Manual, select the Driver Runtime line. When the Startup button becomes
active, click the button to toggle the Startup mode to Automatic.
3. Click OK to close the Project Status dialog.
4. Start the application to run the driver.
TWCAT Driver Version 1.03
Doc. Revision D January 6, 2005
Page 13/16
Troubleshooting
If the TWCAT driver fails to communicate with the device, the tag you configured for the Read Status or Write Status
fields will receive an error code. Use this error code and the following table to identify what kind of failure
occurred.

Error Code Description Possible Causes Procedure to Solve
0 OK Communication without problems None required
1 Invalid AmsNet ID Station Invalid AmsNet ID Station. The AmsNet ID must
have 6 numbers.
Type a valid AmsNet ID.
30 Error loading third party library The third party library is not installed
(tcAdsDll.dll or tcADsDllCE.dll).
Install the third party library TwinCAT ADS
Interface PLC software.
40 Error loading extern function The extern function can not be loaded. Install the correct tcAdsDll.dll or tcAdsDllCE.dll
library. The library exists, but the extern functions
cannot be loaded.
50 Invalid command Header in the Driver Worksheet is invalid. Type a valid header.
60 Invalid datatype Specified address contains an invalid value Type a valid address.
70 Error in the GetLocalAddress
function
The TwinCAT ADS Interface PLC is not working
properly, or TwinCAT software is not running.
Contact your Studio technical support
representative.
90 Error writing data The TwinCAT ADS Interface PLC is not working
properly, or TwinCAT software is not running.
Note the error text in the LogWin, and contact your
Studio technical support representative.
100 Error in the
ADSIGRP_SYM_READWRITE
(InfoByNameEx) service
Cannot load the TwinCAT PLC variables
information. The TwinCAT ADS Interface PLC is
not working properly, TwinCAT software is not
running, or the configured variable name is not
configured in the TwinCAT PLC software.
Note the error text in the LogWin, and contact your
Studio technical support representative.
110 Error in the
ADSIGRP_SYM_READWRITE
service
Cannot read the TwinCAT PLC variables
values. The TwinCAT ADS Interface PLC is not
working properly, or TwinCAT software is not
running.
Contact your Studio technical support
representative.

120 Error processing value The configured variable name or address is not
configured in the TwinCAT PLC software or is
out of range.
Note the error text in the LogWin, and contact your
Studio technical support representative.
130 BlockSize Error Address or variable configured in Driver sheet is
over the limit.
Only 128 addresses or variables can be configured
per Driver Sheet.
140 Too many connections AmsNetID is over the limit.
Only 64 AmsNetID addresses can be configured.
-15 Timeout Start Message
Disconnected cables
PLC is turned off, in stop mode, or in error
mode
Wrong station number
Wrong RTS/CTS control settings
Check cable wiring.
Check the PLC state it must be RUN.
Check the station number.
Check the configuration. See Studio Technical
Reference Manual for information about valid
RTS/CTS configurations.
-17 Timeout between rx char
PLC in stop mode or in error mode
Wrong station number
Wrong parity
Wrong RTS/CTS configuration settings
Check cable wiring.
Check the PLC state it must be RUN.
Check the station number.
Check the configuration. See Studio Technical
Reference Manual for information about valid
RTS/CTS configurations.

TWCAT Driver Version 1.03
Doc. Revision D January 6, 2005
Page 14/16


Tip:
You can verify communication status using the Studio development environment Output window (LogWin
module). To establish an event log for Field Read Commands, Field Write Commands and Serial Communication,
right-click in the Output window. When the pop-up menu displays, select the option to set the log events. If
you are testing a Windows CE target, you can use the Remote LogWin of Studio (Tools Remote LogWin) to
get the log events from the target unit remotely.

If you are unable to establish communication with the PLC, try to establish communication between the PLC
Programming Tool and the PLC. Quite frequently, communication is not possible because you have a hardware
or cable problem, or a PLC configuration error. After successfully establishing communication between the
devices Programming Tool and the PLC, you can retest the supervisory driver.
To test communication with Studio, we recommend using the sample application provided rather than your new
application.
If you must contact us for technical support, please have the following information available:
Operating System (type and version): To find this information, select Tools System Information.
Studio Version: To find this information, select Help About.
Driver Version: To find this information, read the full description of the driver on the Communication Drivers
dialog.
Communication Log: Displays in the Studio Output window (or LogWin window) when the driver is running. Be
sure to enable the Field Read Commands, Field Write Commands and Serial Communication for the LogWin window.
Device Model and Boards: Consult the hardware manufacturers documentation for this information.
TWCAT Driver Version 1.03
Doc. Revision D January 6, 2005
Page 15/16
Sample Application
You will find a sample application for drivers in the /COMMUNICATION EXAMPLES/TWCAT directory. We strongly
recommend that you check for a sample application for this driver and use it to test the driver before configuring
your own customized application, for the following reasons:
To better understand the information provided in each section of this document.
To verify that your configuration is working satisfactorily.
To certify that the hardware used in the test (device, adapter, cable and PC) is working satisfactorily before
you start configuring your own, customized applications.


Note:
This application sample is not available for all drivers.

Use the following procedure to perform the test:
1. Configure the devices communication parameters using the manufacturers documentation.
2. Open and execute the sample application.


Tip:
You can use the sample application screen as the maintenance screen for your custom applications.

TWCAT Driver Version 1.03
Doc. Revision D January 6, 2005
Page 16/16
Revision History

Doc.
Revision
Driver
Version
Author Date Description of changes
A 1.00 Roberto Vigiani, Jr. Jan/28/2004 First driver version
B 1.01 Roberto Vigiani, Jr. Feb/04/2004 Modified the extern function to dynamic mode
C 1.02 Fabio H.Y. Komura Oct/27/2004
- Implemented remote access
- Accessed all runtimes
- Increased read performance
D 1.03 Bruno A. Crepaldi Jan/06/2005 Modified to accept any port number in the Station field.