PRESSURE SWITCH
UL, cUL, and CSFM Listed, FM and LPC Approved, NYMEA
Accepted, CE Marked
Dimensions: 3.78" (9,6cm)W x 3.20" (8,1cm)D x 4.22" (10,7cm)H
Conduit Entrance: Two knockouts provided for 1/2" conduit. Individual
switch compartments and ground screws suitable for
dissimilar voltages.
Enclosure: Cover - Die-cast with textured red powdercoat finish, single
cover screw and rain lip.
Base - Die-cast
Pressure Connection: Nylon 1/2" NPT Male
Factory Adjustment: 4 - 8 PSI (0,27 - 0,55 BAR)
Differential: 2 PSI (0,13 BAR)
Patent Pending
Maximum System Pressure: 300 PSI (20,68 BAR)
Cover Tamper: Cover incorporates subminiature switch activated by Switch Contacts: SPDT (Form C)
cover removal. 10.1 Amps at 125/250VAC, 2.0 Amps at 30VDC
One set SPDT (Form C) contacts One SPDT in PS10-1, Two SPDT in PS10-2
3 Amps at 250V AC
Environmental Specifications:
5 Amps at 125V AC
NEMA 4/IP55 Rated Enclosure - indoor or outdoor when used
1 mA at 5V DC minimum
8" (20 cm) 22AWG wire leads with NEMA 4 conduit fittings.
Temperature range: -40°F to 140°F (-40°C to 60°C)
One or two family dwelling NFPA-13D Service Use:
Residential Occupancy up to four stories NFPA-13R
Automatic Sprinkler NFPA-13
National Fire Alarm Code NFPA-72
Models: PS10-1 w/TSK, PS10-1 w/TSK and Brass Bushing
PS10-2 w/TSK, PS10-2 w/TSK and Brass Bushing
Installation
The Potter PS10 Series Pressure Actuated Switches are designed for the Insure that no unsupervised shut-off valves are present between the alarm
detection of a waterflow condition in automatic fire sprinkler systems of check valve and PS10.
particular designs such as wet pipe systems with alarm check valves, dry Method 2: When using the PS10 for local bell application or with a control
pipe, preaction, or deluge valves. The PS10 is also suitable to provide a that does not provide a retard feature - the PS10 must be installed on the alarm
low pressure supervisory signal; adjustable between 4 and 15 psi (0,27 and outlet side of the retard chamber of the sprinkler system.
1,03 BAR). Testing: Accomplished by opening the inspector's end-of-line test valve.
1. Apply Teflon tape to the threaded male connection on the device. Allow time to compensate for system or control retard.
(Do not use pipe dope) Note: Method 2 is not applicable for remote station service use, if there is an
2. Device should be mounted in the upright position (threaded connection down). unsupervised shut-off valve between the alarm check valve and the PS10.
3. Tighten the device using a wrench on the flats on the device.
Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com
NG
2.87 MI
CO
[72.97] IN
ADJUSTMENT
KNOB 4.22
[107.19]
1/2" NPT
NG
OI DWG# 923-3
TG
2.48 1.60 OU
[62.87] [40.64]
3.78 3.20
[95.89] [81.28]
NOTE: To prevent leakage, apply teflon tape sealant to male threads only. An uninsulated section of a single conductor
should not be looped around the terminal and
serve as two separate connections. The wire
must be severed, thereby providing supervision
Use of pipe joint cement may result in obstruction of the aperture and
of the connection in the event that the wire
loss of signal.
becomes dislodged from under the terminal.
PS10
PS10 PS10
WATER WATER WATER
MOTOR MOTOR MOTOR
GONG GONG GONG Closing of any shutoff valves between the
CHECK
WET
RBVS
RBVS DRY VALVE RBVS alarm check valve and the PS10 will render
SYSTEM WET SYSTEM
ALARM SYSTEM ALARM the PS10 inoperative. To comply with
CHECK ALARM CHECK
VALVE CHECK RETARD VALVE NFPA-72 any such valve shall be electrically
VALVE
WATER WATER WATER supervised with a supervisory switch such as
OS & Y BY-PASS BY-PASS OS & Y BY-PASS
OS & Y
VALVE VALVE
VALVE VALVE VALVE VALVE Potter Model RBVS.
DWG. #923-2AA
Low Pressure Signal Connection Waterflow Signal Connection Local Bell For Waterflow Connection
Fig. 4 Fig. 5 Fig. 6
NEGATIVE DC
TO FIRE ALARM PANEL TO FIRE ALARM PANEL OR NEUTRAL AC
EOLR EOLR BELL
LINE LOAD
POSITIVE DC
OR HOT AC
Removing Knockouts Shown With Cover Tamper Switch Installed Ordering Information
Fig. 9 Fig. 10
Model Description Stock No.
PS10-1 Single Switch w/TSK and Nylon Connection 1340105
PS10-1 Single Switch w/TSK and Brass Connection 1340107
WHT RED
COM NO
WITH COVER
INSTALLED
PS10-2 Double Switch w/TSK and Nylon Connection 1340106
BLK
NC
PS10-2 Double Switch w/TSK and Brass Connection 1340108
Hex Key 5250062
Cover Tamper Switch Kit 0090200
DWG# 1340-2
• Installation must be performed by qualified personnel and in accordance with all • Do not tighten by grasping the switch enclosure. Use wrenching flats on the
national and local codes and ordinances. bushing only. Failure to install properly could damage the switch and cause
• Shock hazard. Disconnect power source before servicing. Serious injury or death improper operation resulting in damage to equipment and property.
could result.
• To seal threads, apply Teflon tape to male threads only. Using joint compounds or
• Read all instructions carefully and understand them before starting installation. Save
cement can obstruct the pressure port inlet and result in improper device operation
instructions for future use. Failure to read and understand instructions could result
in improper operation of device resulting in serious injury or death. and damage to equipment.
• Risk of explosion. Not for use is hazardous locations. Serious injury or death could result. • Do not over tighten the device, standard piping practices apply.
Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Téléphone : 1-800-325-3936/Canada 1-888-882-1833 • www.pottersignal.com
FILETAGE
IE
NPT 1/2 PO RT DWG# 923-3
SO
DE
2,48 1,60
[62,87] [40,64]
3,78 3,20
[95,89] [81,28]
NOTA : pour empêcher les fuites, utiliser du ruban pour joints filetés sur les tuyaux avec filetage seulement. Une section non isolée d’un conducteur
unifilaire ne doit pas être enroulée autour d’une
borne ni être utilisée comme deux connexions
distinctes. Le câble doit être coupé, ce qui
L’utilisation de ciment pour joints filetés peut causer un blocage de permettra de surveiller la connexion si le câble
l’ouverture et une perte de signal. venait à se détacher de la borne.
PS10
À PRESSION NORMALE SOUS AIR
ATTENTION
PS10 PS10
CLOCHE CLOCHE
HYDRAULIQUE HYDRAULIQUE La fermeture d’un robinet d’arrêt entre le clapet
CLOCHE
CLAPET
CLAPET
COMMUTATEUR
DE ROBINET À
HYDRAULIQUE
CLAPET
COMMUTATEUR ANTI-
COMMUTATEUR
DE ROBINET À
anti-retour d’alarme et le PS120 désactive le
DE ROBINET À RETOUR CLAPET DE
ANTI- BILLE ADAPTÉ ANTI- BILLE ADAPTÉ
RETOUR RETOUR
BILLE ADAPTÉ D’ALARME
POUR
NON-RETOUR PS120. Pour se conformer aux normes NFPA-72,
D’ALARME D’ALARME SYSTÈME
POUR
SYSTÈME
POUR
SYSTÈME RETARDATEUR
D’EXTINC tout robinet de ce type doit faire l’objet d’une
TEURS
D’EXTINCT D’EXTINCT
EURS EURS
SOUS AIR surveillanceélectriqueàl’aided’uncommutateur
ROBINET DE ROBINET DE ROBINET DE
ROBINET
À TIGE
DÉRIVATION ROBINET
À TIGE
DÉRIVATION
ROBINET
À TIGE
DÉRIVATION de surveillance électrique, comme le modèle de
MONTANTE MONTANTE MONTANTE
ET À FILETAGE ET À FILETAGE ET À FILETAGE commutateur RBVS de Potter.
EXTÉRIEUR EXTÉRIEUR EXTÉRIEUR DWG. #923-2AA
Connexion Du Signal De Pression Faible Connexion Du Signal De Débit D’eau Alarme Sonore Locale Pour Une Connexion
Fig. 4 Fig. 5 Surveillant Le Débit D’eau
Fig. 6
VERS LE PANNEAU D’INCENDIE VERS LE PANNEAU D’INCENDIE CC NÉGATIF OU
RÉSISTANCE CA NEUTRE
RÉSISTANCE D’EXTRÉMITÉ SIGNAL
DE LIGNE
D’EXTRÉMITÉ
DE LIGNE LIGNE CHARGE SONORE
CC POSITIF OU CA
COMM. SOUS TENSION
COMM.
Borne C
Détacher une petite section du séparateur pour pouvoir passer le câblage
C : Commun
de deux commutateurs à partir d’une seule ouverture de conduit. 1 : Fermé à une pression de système normale.
NO
NR
EN PLACE embout en laiton 1340107
NC PS10-2 Commutateur double avec TSK et
embout en nylon 1340106
PS10-2 Commutateur double avec TSK et
embout en laiton 1340108
Clé hexagonale 5250062
Ensemble de commutateur de
couvercle anti-sabotage 0090200
DWG# 1340-2
• L’installation doit être effectuée par du personnel compétent, conformément à tous les • Ne pas serrer en saisissant le boîtier du commutateur. Utiliser les surfaces de serrage
codes et à toutes les ordonnances nationaux et locaux. de la bague seulement. Une installation inappropriée pourra endommager le
• Risque de choc électrique. Débrancher l’alimentation avant d’effectuer l’entretien. commutateur et causer un mauvais fonctionnement pouvant ensuite endommager
Le non-respect de ces consignes peut causer des blessures ou la mort. l’équipement et la propriété.
• Lire attentivement toutes les directives et s’assurer de bien les comprendre avant • Pour sceller les filetages, utiliser du ruban pour joints filetés seulement sur les embouts
de commencer l’installation. Conserver les directives pour référence ultérieure. Ne pas mâles. L’utilisation de pâte ou de ciment à joints peut causer un blocage de la prise
lire et ne pas bien comprendre les directives peut entraîner un mauvais fonctionnement
de l’orifice de refoulement, un mauvais fonctionnement du dispositif et endommager
du dispositif pouvant causer des blessures graves ou la mort.
l’équipement.
• Risque d’explosion. Ne pas utiliser dans des zones dangereuses. Cela pourrait causer des
blessures ou la mort. • Ne pas trop serrer le dispositif, suivre les précautions standard pour les conduits
de ce type.