1

S.No ITEM QTY UNIT RATE


1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual
means in over areas foundation trenches or drains (not exceeding 1.5 min width or
10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5
m, including getting out the excavated soil and disposal of surplus excavated soil as
directed, within a lead of 50 m.
2.6.1 All kinds of soil.
3466.08 Cum 123
Extra for every additional lift of 1.5 m or part thereof sor 2.25.1 all kinds of soil
866.52 Cum 23
2 Supplying and filling in plinth with crusher stone dust/ coarse sand under floors
including, watering, ramming consolidating in layers not exceeding 20cm in depth
in layers not exceeding 20cm in depth and dressing complete. SOR 2.27/7
559.200 Cum 388
3 4.1 Providing and laying in position cement concrete of specified grade excluding
centering and shuttering - All worki upto plinth level.4.1.2 With 40mm nominal size
graded stone aggregate4.1.2.3 M 7.5
370.300 Cum 2928
4 Providing and laying in position machine batched, machine mixed and machine
vibrated design mix cement concrete of specified grade for reinforced cement
concrete work including all lift of concrete to si te of laying but excluding the cost
of centering, shuttering, finishing and reinforcement, including admixtures in
recommended proportions as per IS 9103 to accelerate, retard setting of concrete,
improve workability without impairingstrength and durability as per direction of
Engineer-in-charge. M-20 grade reinforced cement concrete by using 403 kg of
cement per cum of concrete.
All work upto floor II level. SOR I. 5.26 P.08
2239.420 Cum 5014
5 Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations etc. in layers not exceeding 20cm in depth, consolidating each
deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. SOR
2.24/7
1839.37 Cum 56
6 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding including cost of binding wire up to floor two level including
all wastage etc. complete. 5.16.1 Mild steel and Medium Tensile steel bars.
233067.28 Kg 48.0
7 Centering and shuttering including strutting, propping etc. and removal of form
work for : 5.9.2 Walls (any thickness) including attached pilasters butteresse s,
plinth beams and string courses etc.up to plinth level.
3255.96 Sqm 146
8 6 .2 Brick work with well burnt chimney bricks in bulls patent trench kiln, crushing
strength not less than 25kg /sqcm and water absorption not more
than 20% in foundation and plinth SOR item 6.2.2/page 27
6.2.2 Cement Mortar 1:6 (1 cement : 6 sand). 714.82 Cum 2519
9 11.25 40 mm thick stone flooring over 20 mm (average)thick base of cement
mortar 1:5 (1 cement : 5 sand) including pointing with cement mortar 1:2 (1
cement : 2 sand) with an admixture of pigment to match the shade of stone. Red
sand stone / White sand stone 11.25.1 Rough chiseled dressed stone
266.80 Sqm 307
10 Reinforced cement concrete work in beams, suspended floors, roofs having slope
of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window
sills, staircases and spiral stair cases up to floor two level excluding the cost of
centering, shuttering, finishing and reinforcement in concrete grade. 5.2.1 M 20
Nomial mix /P-20
47.76 Cum 4442
Revised Estimate Based On MP PWD SOR wef 15 JUNE 2009 & ammended from 11.09.2012
M.P. Police Housing Corpn. Ltd., Ujjain Division, Ujjain
Schedule of Items
Construction of Barrack at D.R.P.Line, Ujjain
2
S.No ITEM QTY UNIT RATE
11 Reinforced cement concrete work in beams, suspended floors, roofs having slope
of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window
sills, staircases and spiral stair cases up to floor two level excluding the cost of
centering, shuttering, finishing and reinforcement in concrete grade. 5.3.1 M 20
Nomial mix /P-20
GROUND FLOOR
498.208 Cum 5014
Add 2 % for lift 50.180 Cum 100.28
12 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding including cost of binding wire up to floor two level including
all wastage etc. complete. 5.16.1 Mild steel and Medium Tensile steel bars.
Add 1% for lift 52200 Kg 0.48
Add 2 % for lift 5018 Kg 0.96
13 Centering and shuttering including strutting, propping etc. and removal of form for
: 5.9.3 Suspended floors, roofs, landings, balconies and access platform. Shelves
(Cast in situ) Lintels, beams, beams, girders, bressumers and cantilevers, Columns,
Pillars, Posts and Struts Walls in super structure.
9769.76 Sqm 229
14 5.9.4 All types of staircases i/c riser & landings
144.12 Sqm 285
15 Brick work with well burnt chimney bricks in bulls patent trench kiln ,crushing
strength not less than 40kg /sqcm and water absorption not more than 15 % in
foundation and plinth SOR 6.2.2
Add 2% for lift 94.170 Cum 50.38
16 Half brick masonary with m.s. brick of class designation 25 in superstrucure above
plinth level upto floor II .6.11.2 CM (1:4)
1300.80 Sq m 347
17 Extra for providing and placing in position 2 nos 8mmdia. M.S. bars at every course
of half brick masonary.
1300.80 Sq m 55
18 Cement plaster in C.M. 1:4 - 12 mm SOR item 13.1.1 page 99
GROUND FLOOR
4651.76 Sqm 92
19 18 mm Cement plaster in two coats SOR item 13.6
5512.76 Sqm 135
20 Cement plaster in C.M. 1:6 - 15 mm SOR item 13.2.2 page 99
3072.00 Sq m 107
21 Kota / cuddapah stone slab flooring over 20 mm (average) thick base laid over and
jointed with grey cement slurry mixed with pigment to match the shade of the slab
including rubbing and polishing complete with base of cement mortar 1 : 4 (1
cement : 4 sand) :11.23.1 - 25 mm thick.
Quantity for 2 floors 4358.730 Sqm 771
22 6 mm cement plaster of mix C.M. 1:3 Asper SOR 13.8
Quantity for 2 floors 3425.32 Sqm 79
23 Providing & fixing factory made PVC door frame of size 50x47 mm with a wall
thkness of 5 mm mad out of extruded 5 mm rigid PVC foam sheet as per SOR item
9.119
Doors D2 600.00 RM 439
24 30 mm thk. Factory made solid both side pre laminated panel PVC door shutter
consisting of frame made out of MS tube of 19 gauge thkness & size 19x19 for
styles etc complete as per SOR 9.120.2
Doors D2 201.60 Sqm 2916
3
S.No ITEM QTY UNIT RATE
25 Providing and fixing pressed steel door frames confirming to IS: 4351manufactured
from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock
jamb, bead and if required angle threshold of mild steel angle of section 50x25mm,
or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by
mechanical means, adjustable lugs with split end tail to each jamb including steel
butt hinges 2.5mmthick with mortar guards, lock strike- plate and shock absorbers
as specified andapplying a coat of approved steel primer after pre-treatment of the
surface as directed by Engineer-in-charge: 10.14.2 Single rebate ( 100 mm x 50
mm)
480.00 RM 380
26 Providing and fixing ISI marked flush door shutters conforming to IS: 2202
(Part I) non-decorati ve type, core of block board construction with frame of
1st class hard wood and well matched commercial 3 ply veneering with
vertical grains or cross bands and face veneers on both faces of shutters 9.21.2
30 mm thick including ISI marked Stainless Steel butt hinges with necessary
screws
249.48 Sqm 1283
27 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and
screws etc. complete : 9.62.1 300x16 mm
412 No 107
28 Providing and fixing bright finished brass tower bolts (barrel type) with necessary
screws etc. complete :
9.74.1 250x10 mm S.O.R.P-23
232 No 282
29 Providing and fixing bright finished brass handles with screws etc. complete .9.81.1
125 mm S.O.R.P-23
412 No 122
30 Providing and fixing aluminium work for doors, windows, ventilators and partitions
with extruded built up standard tubular sections/ appropriate Z sections and other
sections of approved make conforming to IS: 733 and IS : 1285, all complete as
per drawings and the directions of Engineer-in-charge: 21.1.2.2 Powder coated
aluminium (minimum thickness of powder coating 50 micron)
4761.6 Kg 293
31 Providing & fixing glazing in aluminium windows, ventilators & partition etc. as per
item no. 10.25.1- With float glass 4 mm thick
476.16 Sqm 743
9.52 Add extra for providing S.S wire gauge of average width of aperture 1.4mm
with wire gauge of 0.63mm instead of M.S wire gauge for item 9.27, 9.28, 9.29,
9.30, 9.51
238.08 Sqm 209
32 Filling gap in between aluminium frame & adjecent RSS/brick/stone work by
providing weathar silicon sealent over backer rod of approved quality as per SOR
21.6.1 up to 5 mm depth & 5 mm width
1886.4 RM 71
33 Steel work welded in builtup sections for frame work all type sections, trusses and
framed work, including cutting, hoisting, fixing in position and applying a priming
coat of approved steel primer all complete: SOR item 10.23
9486.72 Kg 64
34 Providing and fixing hand rail of approved size by welding etc. to steel ladder
railing, balcony railing and staircase railing including applying a priming coat of
approved steel primer.10.24.1 M.S. tube SOR P.36
7650.0 Kg 81
35 Providing & fixing first quality ceramic glazed wall tiles conforming to IS :15622(6-7
mm thk)of approved make in all coloursshades any size as approved by E-in-
chargein skirting, & dados over 12 mm thk bed of cement mortor 1:3 with jointing
etc. complete SOR 11.31
4
S.No ITEM QTY UNIT RATE
1688.48 Sqm 629
36 Providing & laying ceramic glazed floor tiles conforming to IS :15622 of approved
make in colours shades any size as approved by E-in-chargein skirting, & dados
over 12 mm thk bed of cement mortor 1:4 with jointing etc. complete SOR 11.32
248.40 Sqm 848
37 Grading Roof for water proofing treatment with CC 1:2:4 as per SOR 22.14.1
142.680 Cum 3994
38 Grading roof for water proofing treatment with 22.14.2 Cement mortar 1:3 (1
cement : 3 sand) SOR 22.14.2 P/91
24.46 Cum 6450
39 Providing and laying water proofing treatment in sunken portion of WCs, bathroom
etc., by applying cement slurry mixed with water proofing cement compound
consisting of applying : a) First layer ofslurry of cement @0.488 kg/sqm mixed with
water proofing cementcompound @0.253 kg/sqm. This layer will be allowed to air
cure for 4hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with
water proofing cement compound @0 126 kg/sqm This layer will be allowed to air
cure for 4 h ours followed with 0.126 sqm. water curing for 48 hours. The rate
includes preparation of surface, treatment and sealing of all joints,corners,
junctions of pipes and masonry with polymer mixed slurry. ( with five years service
gurantee).SOR P.NO.89 I.No.22.5
643.92 Sqm 168
40 Providing and applyoing JK or Birla or equivalent wall care exterior or interior mix
putty for outer surfaces i/c sand papering for making the surface smooth for
applying any paint with all cost of material and labour and scaffolding etc. in all
positions complete item no. 13.7 page 106 inclusive of ceiling area
qty same as inner plaster + ceiling 11151.32 Sqm 95
41 Distempering with oil bound washable distemper of approved brand and
manufacture to give an even shade
13.30.1 New work (two or more coats) over and including priming coat with
cement primer sor 13.30.1 p-49
qty same as inner plaster 7725.76 sqm 52
42 13.35 Finishing walls with Acrylic mooth exterior +paint of required shade: 13.35.1
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including
base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm).
qty same as outer plaster 5512 sqm 68
43 10.17 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar bent to
shape with hooked ends in R.C.C. slabs, beams during laying including painting the
exposed portion of loop, all as per standard design complete.
300 no. 87
44 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan
clamp of internal dia 140mm, 73mm height,top lid of 1.5mm thick M.S. sheet with
its top surface hacked for proper bonding, top lid shall be screwed into the cast
iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the
corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard
drawing.SOR P.NO.35 I.NO. 10.18
300 No 140
45 Painting with synthetic enamel paint of approved brand and manufacture of
required colour to give an even shade:
13.50.1 Two or more coats on new work over an under coat of suitable shade with
ordinary paint of pproved brand and manufactureSOR item 13.50.1/50
1178.64 Sqm 64
INTERNAL WATER SUPPLY & SANITARY
5
S.No ITEM QTY UNIT RATE
1 Providing and fixing white vitreous china pedestal type water closet
(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.
flushing cistern with manually controlled device (handle lever), conforming
to IS : 7231, with all fittings and fixtures complete including cutting &
making good the walls and floors wherever required :
S.O,R.P-133/It.No.17.2.1
17.2.1 W.C. pan with ISI marked white solid plastic seat and lid 24.00 Each 2657.00
2 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with
100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing
cistern with manually controlled device (handle lever) conforming to IS :
7231, with all fittings and fixtures complete including cutting and making
good the walls and floors wherever required : S.O.R.P-133/It.No.17.1.1
17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440mm
with integral type foot rests. 48.00 Each 2838.00
3 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar
taps,32 mm C.P. brass wa ste of standard pattern, including painting of
fittings and brackets, cutting and making good the walls wherever require :
White Vitreous China Flat back wash basin size 550x400mm with single 15
mm C.P. brass pillar taps. S.O.R.P-134/It.No.17.7.4
17.7.4) White Vitreous China Flat back wash basin size 550x400mm with
single 15 mm C.P. brass pillar tap. 48.00 Each 1356.00
4 Providing and fixing Stainless Steel ISI 304 (18/8) kitchen sink as per IS
13983 with C.I. brackets and 40 mm stainless steel plug including painting
of fittings and brackets, cutting and making good the walls wherever
required : S.O.R.P-136/It.No.17.10.1.1
17.10.1.3) Kitchen sink with drain board 17.10.1.1 510x1040 mm bowl
depth 200mm. 8.00 Each 4041.00
5
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply including all CPVC plain & brass threaded
fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of
pipes & fittings with one step CPVC solvent cement and the cost of cutting
chases and making good the same including testing of joints complete as per
direction of Engineer in Charge. SOR P/291 I/18.7.1,2,3
Internal work Exposed on wall.
18.10.1) 15 mm dia. nominal bore 800.00 R.M. 98.00
18.10.2) 20 mm dia. nominal bore 1000.00 R.M. 116.00
18.10.3) 25 mm dia. nominal bore 100.00 R.M. 150.00
6 Making connection of G.I. distribution branch with G.I. main of following
sizes by providing and fixing tee, including cutting and threading the pipe
etc. complete : S.O.R.P-154/It.No.18.13
18.13.1) 25 to 40 mm nominal bore 8.00 Each 191.00
7 Providing and fixing C.P. brass pillar cock approved quality and make
conforming to IS:specification. 15 mm nominal bore 125 mm long foam
flow. S.O.R.P-162/It.No.18.54 48.00 Each 576.00
8 Providing and fixing C.P. brass long body bib cock of approved quality
conforming to IS standards and weighing not less than 690 gms. S.O.R.P-
161/It.No.18.51.1
18.51.1 )15 mm nominal bore . 80.00 Each 363.00
9 Providing and fixing C.P. brass angle valve for basin mixer and geyser points
of approved quality conforming to IS:8931 a) 15 mm nominal bore.
S.O.R.P-161/It.No.18.53.1
6
S.No ITEM QTY UNIT RATE
18.53.1 15mm nominal bore 120.00 Each 400.00
10
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
S.O.R.P-155/It.No.18.22.1
18.22.1) 100 mm diameter 60.00 Each 518.00
11 Providing and fixing brass stop cock of approved quality : S.O.R.P-
154/It.No.18.16.1,2
60.00 Each 221.00
12 Providing and fixing gun metal gate valve with C.I. wheel of 18.16.1 15 mm
nominal bore 0.40kg 18.16.2 20 mm nominal bore 0.75kg approved quality
(screwed end) : S.O.R.P-154/It.No.18.17.2,3
18.17.3) 25 mm nominal bore 16.00 Each 329.00
13
Providing and fixing square-mouth S.W. gully trap grade 'A' complete with
C.I. grating brick masonry chamber with water tight C.I. cover with frame of
300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg
and frame to be not less than 2.70 kg as per standard design : With Modular
Bricks class designation 40. S.O.R.P-
170/It.No.19.4.2
19.4.2) 150 x 100 mm size P type. 16.00 Each 1106.00
14
Supplying and fixing C.I. cover 300x300mm without frame for gully
trap(standard pattern( the weight of cover to be not less than 4.50 Kg.
S.O.R.P-170/It.No.19.2
16.00 Each 236.00
15 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast
iron/cast iron (spun) pipe embedded in and including cement concrete
blocks 10x10x10cm of 1:2:4 mix (1 cement :2 sand:4 graded stone
aggregate 20mm nominal size) including cost of cutting holes and making
good the walls etc. : S.O.R.P-139/It.No.17.37.1,2
17.37.1) For 100 mm dia. Pipe 80.00 Each 82.00
17.37.2) For 75 mm dia. Pipe 80.00 Each 79.00
16
Providing and fixing on wall face unplasticised Rigid PVC Rain water pipes
conforming to IS : 13592 Type A including jointing with seal ring conforming
to IS : 5382 leaving 10 mm gap for thermal expansion.for soil and wast
pipes Single socketed pipes for working pressure of 4 kg./cm2 S.O.R.P-
145/It.No.17.74.3
17.74.1 75 mm diameter 440.00 R.M. 156.00
17.74.3) 110 mm diameter 600.00 R.M. 259.00
17
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C.
waste fittings complete. S.O.R.P-/It.No.17.28
Semi rigid pipe
32 mm dia
56 each 67.00
18
Providing and fixing on wall face unplasticised - PVC moulded fittings/
accessories for nplasticised Rigid PVC Rain water pipes conforming to IS :
13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10
mm gap for thermal expansion.S.O.R.P-/It.No.17.75
Coupler
75 mm
168 each 183.00
110 mm
72 each 245.00
Single tee with door
75x75x75 mm
88 each 308.00
110x110x110 mm
88 each 459.00
Bend 87.5
75 mm bend
104 each 163.00
110 mm bend
104 each 259.00
Shoe
75 mm Shoe
104 each 277.00
7
S.No ITEM QTY UNIT RATE
17. 75.6.3 110 mm Shoe
104 each 485.00
EXTERNAL SANITARY WATER SUPPLY
1 Providing and laying below ground unplasticised PVC pipe to with stand
working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 and
IS:4985 including jointing with seal ring confirming to IS :5282 leaving
10mm gap for thermal expansion all necessary fittings etc. complete.
SOR I.No.19.35.1,2,3 P.84
19.35.2 160 mm diameter OD 175.00 Rm 450.00
2 Providing and laying cement concrete 1:5:10 (1 cement : 5 sand : 10 graded
stone aggregate 40 mm nominal size) all-round PVC. pipes including bed
concrete as per standard design:
SOR I.No.19.36.1,2,3 P.84
19.36.2 150 mm diameter PVC. pipe 175.00 Rm 466.00
3 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4
sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 sand : 4 graded stone
aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement :
4
sand : 8 graded stone aggregate 40mm nominal size) inside plastering
12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with
floating coat of neat cement and making channels in cement concrete 1:2:4
(1 cement : 2 sand : 4 graded stone aggregate 20mm nominal standard
design : With modular bricks with class designation 40
19.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame
(light duty) 455x610 mm internal dimensions total weight of cover and
frame to be not less than 38 kg (weight of cover 23 kg and weight of frame
15 kg) :
SOR P.No. 81 I.No. 19.7.1 20.00 each 5293.00
4 Providing and fixing G.I. pipes complete with G.I. fittings including trenching
and refilling etc. External work
SOR I.No. 18.12.5 P. 71
18.12.5 40 mm dia. nominal bore 300.00 Rm 293.00
SOR I.No. 18.12.3 P. 71
SOR I.No. 18.12.6 P. 71 50.00 Rm 459.00
5 Providing and fixing gun metal gate valve with C.I. wheel of approved
quality (screwed end) :
SOR I.No.18.17.5 P. 71
18.17.5 40 mm nominal bore 6.00 each 459.00
18.17.6 50 mm nominal bore 4.00 each 665.00
6 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of
required shape and approved quality 20.00 each 1015.00
19.19.1.1 Rectangular shape 600x450mm internal dimensions
SOR I.No. 19.19.1.1 P.
DEVELOPMENT WORK
1 Excavation for roadway in soil including loading in truck for carrying of cut
earth to embankment site with all lifts and lead upto1000 metres and as per
relevant clauses of section-300
SOR P.No. 5 I.No. 3.1 90.00 cum 122.00
8
S.No ITEM QTY UNIT RATE
2 By Mix in Place Method (Construction of granular sub-base by providing
close graded
material, spreading in uniform layers with motor grader on prepared surface,
mixing by mix in
place method with rotavator at OMC, and compacting with vibratory roller to
achieve the
desired density, complete as per clause 401)
(ii) for grading- II Material
SOR P.NO.18 I.NO. 4.1B(ii) 90.00 cum 541.00
3 Dry Lean Cement Concrete Sub- base (Construction of dry lean cement
concrete Subbase
over a prepared sub-grade with coarse and fine aggregate conforming to IS:
383, the
size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not
to exceed 15:1,
aggregate gradation after blending to be as per table 600-1, cement content
not to be less
than 150 kg/ cum, optimum moisture content to be determined during trial
length construction,
concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching
plant, transported
to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes
vibratory roller,
finishing and curing.)
SOR P.NO. 26 I.NO. 6.1 32.00 cum 2383.00
4 Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain
cement
concrete pavement M-40 grade concrete over a prepared sub base with cement ,
coarse
and fine aggregate conforming to IS 383, maximum size of coarse aggregate not
exceeding
25 mm, mixed in a batching and mixing plant as per approved mix design, transported
to site,
laid with a fixed form or slip form paver, spread, compacted and finished in a
continuous
operation including provision of contraction, expansion, construction and longitudinal
joints,
joint filler, separation membrane, sealant primer, joint sealant, debonding strip,
admixtures as
approved, curing compound, finishing to lines and grades as per drawing as per IRC
15 2011
and as per relevant clauses of section
SOR P.No. 15 I.No.6.3 59.20 cum 5847.00
5 Construction of Shoulders with approved material/selected soil i/c
excavation all lifts &
leads i/c grading to required slope & camber of 4% and compacting using
vibratory roller of
80 to 100 kN static weight to meet requirement as per relevant clause of
400. B Hard
Shoulders (CBR value >12)
SOR P.NO. 19 I.NO. 4.15 B 100.00 cum 223.00
SOR P.No. 4 I.No. 4.1.2.3
6 Providing and laying in position specified grade of reinforced cement
concrete (with 20mm nominal size graded stone aggregate) excluding the
cost of centering, shuttering, finishing and reinforcement - All work up to
plinth level
5.1.1 M 20 Nominal mix
SOR P.No. 6 I.No. 5.1.1
43.07 cum 4526.00
7 Centering and shuttering including strutting, propping etc. and
removal of form for : SOR P.No. 6 I.No. 5.9.3
9
S.No ITEM QTY UNIT RATE
5.9.2 Walls (any thickness) including attached pilasters butteresse s, plinth
beams and string courses etc.up to plinth level.
246.36 sqm 222.00
8
12 mm cement plaster 1:3 (1 cement: 3 sand) finished with a floating coat
of neat cement.
SOR P.No. 47 I.No. 13.4
236.43 sqm 139.00
9 13.13 Extra for providing and mixing water proofing material in cement
plaster work
in proportion recomended by the manufacturers. For each bag of 50 kg
cement used in the mix
SOR P.No. 48 I.No. 13.13 4.00 each 52.00
10 Cement concrete flooring 1:2:4 (1 cement : 2 sand : 4 graded stone
aggregate) finished with a floating coat of neat cement including cement
slurry, but excluding the cost of nosing of
steps etc. complete.(Area of panels not exceeding 2 sqm) SOR P.No. 37
I.No. 11.1.1
11.1.1 40mm thick with 20mm nominal size stone
aggregate. 56.94 sqm 239.00
11 Providing and fixing on wall face unplasticised Rigid PVC Rain water pipes
conforming to IS : 13592 Type A including jointing with seal ring conforming
to IS : 5382 leaving 10 mm gap for thermal expansion.for soil and wast
pipes
Single socketed pipes for working pressure of 4 kg./cm2 17.74.3 110 mm
diameter
(SOR P-68 I/17.74.3) 3.00 Rm 259.00
INTERNAL ELECTRICAL WORK
1 Point wiring (excluding metallic switch box & sheet but including switches,
sockets, lamp holders/ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR
with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit
(HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth
continuity conductor of green colour inside conduit including painting etc. as
required as per specification for :-
Using
Modular
Accessori
es
4.1 4.1 Light Point/Fan Points.
a) Short point 210 Each 275
b) Medium point 400 Each 438
c) Long point 200 Each 630
4.2 4.2 3 Pin 6 Amp socket outlet on Separate Board
a) Short point 80 Each 345
b) Medium point 104 Each 558
4.3 4.3 Call Bell / Buzzer Points
c) Long point 16 Each 636
4.4 4.4 Twin Control light points
c) Long point 40 Each 739
2 Point wiring (excluding metallic switch box & sheet but including switches,
sockets) for 3 pin 6 Amp. Socket outlet point with 1 .5 Sq. mm. PVC insulated cable
FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit
(HMS) ISI marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth
continuity conductor of green colour inside conduit with required materials as
per specification on same board . SOR 4.5
120 Each 219
10
S.No ITEM QTY UNIT RATE
3 Point wiring (excluding metallic switch box & sheet ) for 3 Pin 16 Amp. Socket
Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand
conductor ISI marked in Concealed rigid P.V.C.Conduit (HMS) ISI Marked of suitable
size including painting etc. with 16 Amp. F.T. Switch & Socket / S.S.Combined 16
Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth continuity conductor
of green colour inside conduit as per specification for :- 9.1
Using
Modular
Accessori
es
On Separate Board
B. Medium Point 20 Each 767
C. Long Point 20 Each 1146
D. Extra Long -I 20 Each 1626
4 Supplying and fixing PVC conduit ISI marked alongwith the accessories in concealed
system including painting etc. as required SOR 16.2
PVC . Conduit 25 mm (HMS) 600 Metre 35
5 Supplying and fixing of approved make modular type metal box with modular
frame/ base plate and cover plate including fixing in concealed / surface excluding
switch, socket etc. as required for:- 17.2
1 Or 2 Module 80 Each 53
3 Module 80 Each 65
4 Module 200 Each 74
6 Module 200 Each 112
8 Module 40 Each 149
6 Supplying and drawing single core PVC insulated cable FR with copper multi strand
conductor ISI marked in existing rigid conduit in surface or concealed as per
specification. SOR 4.6
1x1.5 sq mm for inverter 2000 Metre 14
2 X 2.5 sq mm 1600 Metre 20
Wiring for circuit wiring with PVC insulated cable FR with
copper multi strand conductor ISI marked in concealed rigid
P.V.C. conduit (HMS) of ISI marked suitable size including
painting etc. as required as per specification
a) 2x2.5 Sq.mm. 2643 Metre 71
b) 4x2.5 Sq.mm. 200 Metre 109
7 Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB)
of 'C' series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming
to IS : 8828 : 1996, IEC : 60898 :2002 but without enclosures :- SOR 24.3
6 Amp to 32 Amp Rating SP 120 Each 126
6 Amp to 32 Amp Rating TPN 8 Each 822
8 Supplying of approved make TPN MCB DB Metal Double Door with provision for FP
MCB/lsolator/RCCB/RCBO as incomer and SP MCBs as outgoing inclusive of
Busbar, Neutral bar, Earth bar & two earth terminals etc. complete as per IS:13032(
exclusive of MCB & isolator ): SOR 24.6 8Way
8 Each 2492
10 Fixing of MCB / Isolator SP/DP in sheet steel enclosure as required as per accepted
practice, including mounting on busbar and cable connection etc. complete (Labour
only ) SOR 25.4
120 Each 2
11 Labour charges for fixing sheet steel enclosure, MCB DB surface mounting type, as
per accepted practice on 25x5mm flat iron clamps duly embedded in wall, cable
connection etc. complete.
8 Each 53
12 suppling and drawing following pair,0.5 Sq mm PVC Insulated copper conductor
unarmoured telephone cable in existing surface / concealed , steel / PVC Conduit
as required. SOR 26.2
(ii) 2 Pair 200 Metre 19
13 Suppling and drawing Co-axial T.V. Cable RG-6 Grade , 0.7 mm Solid Copper
conductor PE Insulated , Shielded with fine tined copper braid and protected with
PVC Sheath in the existing surface / concealed , steel / PVC. Conduit as required.
600 Metre 23
14 Supplying and fixing as per specification Bulk Head fitting of approved make
suitable for 100 Watt lamp with necessary materials complete.
11
S.No ITEM QTY UNIT RATE
Ordinary 40 Each 65
15 Supplying and fixing as per specification Caution / Danger Board as required of
approved make & design with necessary material complete.
Small Size 8 Each 80
16 Supplying & fixing of approved make industrial type metal plug & socket DBs
(without MCB) SPN sheet enclosur inclusive of 2 pole & earth metal plug complete
as per specification SOR 24.9.2
24 Each 568
17 Supplying & fixing as per specification call bell/buzzer of approved make with
necessary materials complete SOR 26.4.2 Dingdong bell
16 Each 90
18 Supply, fixing & testing Flourescent Tube rod ISI marked of approved make as
required as per specification SOR 26.18.2 - 4 feetx36 Watt
320 Each 41
19 Supply, fixing & testing Flourescent CFL ISI marked of approved make as required
as per specification SOR 26.20.3 - 250 Watt
320 Each 135
20 Suppling and fixing of approved make step type Modular
electronic, Fan regulator including connection etc. as required
on existing board
26.31.1 450 Watt
200 Each 249
21 Supplying & fixing & testing of approved make electric ceiling Fan of double ball
bearing complete with standerd accessories A.C. 230-250 Volts including
connection etc. as required as per IS 374/1979 & ammendments complete SOR
26.29.1
Ceiling Fan Energy saver 50 W 1200 mm sweep 200 Each 1440
22 Supplying & fixing & testing of approved make Exhaust Fan of heavy duty
complete with mounting frame, anchor fasteners etc. A.C. 230-250 Volts
including connection etc. as required complete SOR 26.36.1
80 Each 2481
23 Supply, fixing & testing Flourescent Tube fitting ISI marked of approved make as
required as per specification SOR 26.39 -
320 Each 490
24 Wiring for sub-mains with PVC insulated cable FR with copper
multi strand conductor ISI marked in recessed / concealed
rigid steel ISI marked conduit of suitable size(Conduit included)
including connection painting etc ,as required as per
specification
4 WIRE SUB-MAIN
20.4.3 6.0 sq mm cable in 25 mm conduit 160 Metre 219
25 Supply and Installation of TV socket co-axial with cover plate 80 Each 206
26 Supply and Installation of RJ 11 telephone socket (jack type) with cover plate
80 Each 204
27 Supplying, fixing.testing & commissioning wall / floor mounted LT Panel primer
coated with two coat of enamel paint & provided with required gasket for dust/
vermin proof with degree of protection IP42 suitable for 415V 3 phase ,50 Hz ,4
wire systemfabricated out of CRCA sheet upto 2 mmthick (1 .6 mmfor doors) with
frame work of angle iron/ channel/ bolted type construction duly
compartmentalised for incomer.bus section , outgoings .cable alleys & CT,PT
Ampere Meter ,Volt Meter , selector switches, Frequency Meter .phase indicating
lamps , energy Meter complete including cost of busbar supports.detachable cable
gland plates,2 earthing terminals, internal wiring & fixing of separately supplied
MCBs, MCCBs .panel mounted Changeover switch/SFUs, etc. as required but
excluding cost of busbar strips.Ampere Meter, Volt Meter, Selector switch as per
approved design & specification
200 Kg 95
28 Supplying and fixing heavy duty cable gland for P.V.C. insulated armoured cable
with brass washer, Rubber ring complete erected with cable and lead connection
etc. as per specification complete. SOR 33.6
Gland Size 22mm suitable for cable 2,3,3!4 & 4 x upto 6 Sq.mm 2 Each 29
29 Copper Lugs Pin Type SOR 33.9
a. Upto 25 Sq.mm Conductor Size 100 Each 9
30
Supplying of metal clad ISI Marked busbar chamber made of
heavy gauge iron sheet complete with copper strip and busbar
supports as per specification confirming to IS -4064
23.6 400 AMP 440/500 VOLTS, 4 way 1 Each 3626
23.6 100 AMP 440/500 VOLTS, 4 way
12
S.No ITEM QTY UNIT RATE
31 Supplying of ISI Marked and approved make of Moulded Case Circuit
Breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply
with respective interrupting capacity (KA) at 415 Volts cited against their
range standard conforming to IS -
8828
24.1.1.4 Current Rating -200 Amps & 70% -100% adjustable 1 Each 7800
24.1.1. Current Rating -100 Amps & 70% -100% adjustable 8 Each 4082
32 32.3 Earthing with G.I. Earth plate 600mm X 600mm X 6mm thick including
accessories and providing masonary encloser in cement mortor, cover plate
having locking arrangment on the top and G.I. watering pipe 20mm dia 2.7
Metre long etc. (but without charcoal or coke and salt ) complete as
required.
2 Each 2200
33 32.5 Add Extra for using salt and charcoal / coke for G.I. Plate or Copper
plate earth electrode as required including excavation & refilling. 2 Each 472
34 33.1 Supply of XLPE Insulated power cable (conforming IS-7098 ) 1100 Volt
grade/Heavy duty power cable conforming to IS 1554- 1100 Volts grade , 2
core /3 core/4 coreISI MARKED with Alu. Stranded /solid conductor
33.1.6 ARMOURED 3 CORE
33.1.7.5 150 Sq.mm.(XLPE) 80 Mtr 886
35 33.13.21 Laying of underground cable armoured./ unarmoured as per
specification in air with approved type of iron clamps complete.
33.13.21.2 3 / 3 / 4 Core cable 150 Sq.mm above 80 Mtr 34
36 Supplying of ISI Marked Change over switches in sheet
encloser confirming to IS : 4064 / IS : 13947 (part I & III ) with
side handle operated 4 pole with two earthing terminals
22.3.5 200 Amps. 415/500 Volts.( off load ) 1 Each 11089
Sub-Engineer
M.P.Police Housing Corpn.Ltd.
Ujjain Division, Ujjain
Asstt. Engineer
M.P.Police Housing Corpn.Ltd.
Ujjain Division, Ujjain
Project Engineer
M.P.Police Housing Corpn.Ltd.
Ujjain Division, Ujjain