Sie sind auf Seite 1von 46

Horizon II macro

BSS12 Operation & Maintenance


Objectives
State the functional areas of the Horizon II
macro cabinet.

Describe the functions and operation of
the Horizon II macro Digital modules.
Describe the cabinet RF Components.
Describe the RF Configurations used
with the Horizon II macro cabinet.

By the end of this chapter the student will be able to :-
Site
Controller
(HIISC)
CTU2
Cooling
Fans
Power
Supply
Units
(PSU)
Circuit
Breaker
Card
(CBC)
Alarm
Board
HORIZON II macro Cabinet Front View
Site I/O
Panel
Tx Blocks
Link
Interface
Board
SURF2
Power
Supply
EAS Alarm,
PIX 0 & 1
HORIZON II macro Cabinet Top View
Power Supply Units
Cabinet Power Supply

Maximum 4x PSU per cabinet One for Redundancy
Depends on the number of Radios fitted.

The Cabinet can support the three types of power
supply
+27V (negative earth)
-48V (positive earth)
Nominal 120/240V AC
-48v Power Supply Units
Power supply unit
Power Supply Units
All three unit types support the same PSU
Alarms:
O/P over/under voltage.
I/P under voltage.
Over temperature.
Internal Fan failure.
Circuit Breaker Card (CBC)
6x CCB for CTU2

2x Push Button HIISC

2x Push Button SURF2

1x Tx RF Blocks

1x FAN trays
Temperature control
Cabinet Temperature Control

Operating range -5 C to +45 C

Three Internal FAN units speed controlled

3x Cabinet Temperature Sensors
1x (70 C) for cabinet alarm
2x (85 C) to shutdown the cabinet, reset at 55 C.

Cabinet Fan unit
Alarm Module
Cabinet Alarm Module
Collects All internal Cabinet Alarms
Controls the PIX connection (customer
external alarms)
Process Antenna VSWR alarms

Note: NOT backwards compatible to the
Horizonmacro cabinet
Alarm Board
Mains
Door 1
LVD
Fan 0
Fan 1 & 2
ALL LEDs are
GREEN when the
equipment is OK
RED when
equipment is
faulty
Only 4x active Displays
HorizonII Site Controller (HSCII)
Horizon II Site Controller (HIISC)
Performs functions of: MCUF, NIU, FMUX
and BPSM in Horizonmacro cabinet.

Cabinet supports 2x HIISC cards
Master/Slave ( redundancy)

Compact Flash card (32 Mbyte memory)



Status
LEDs
States LEDs
GREEN (normal
operation) RED
(Fault).
Compact
Flash Slot
Compact Flash
Card slot
contains 32Mb
of memory.
TTY
MMI
TTY MMI
connection for 9
pin D type
connector.
Reset
Buttons
Reset Buttons
CPU is a Soft
Reset (Reset
Controllers
Main
Processors.
Software
remains in
RAM).
FULL is a
Hard reset.
Removes
software from
memory.
CAL
Port
CAL PORT
Calibrates the
Sync Block. The
8K Reference is
used in GCLK
calibration.
NIU
Ethernet
Port
Synch/NIU
TTY PORT
The NIU
Ethernet and
SYNC/NIU TTY
Port are for
factory use only.
H11SC Front
Panel
Horizon II macro HSCII Block diagram
E1 Inputs
x 6 Current
x 8 Future
Uplink RSL
Insertion
16Kbs only
SMuRF
Sync, Mux, uBCU,
Replacement, FPGA
LAPD
Encode/Decode
Layer 2 processing
Field Programmable Gate Array
(FPGA)
similar function as the ASIC
64Kb switch
incapable of sub-rate switching
BTP function of the BTS
runs site software and
call processing functions
CTU2
dual carrier unit
single/dual carrier operation
single frequency band
Three on board
XMUX functions
FMUX equivalent
Second H2SC
configured for
redundancy
Cabinet Expansion
Cabinet Expansion
The Cabinet can be expanded up to 3x
Horizon II macro Cabinets
Can be expanded with Horizonmacro and
Mcell6 cabinet combinations.
Expansion Kit 1x XMUX card
1x Input/Output (I/O) card
1x 2m Fibre Optic cable
XMUX
in slot 0
XMUX
Location
Input/Output Card I/O card


Site Expansion Board
Connects up to 3x extra cabinets
Fibre optic connections

GPS connector (not supported)

Input/Output (I/O) card
GPS
connection
Fibre
connections
IN/OUT


SITE I/O PANEL
CONFIGURATION
Expansion configurations
Horizon II
macro (6xCTU2)


X
M
U
X
Horizon II
macro (6xCTU2)


E1
Two Horizon II macros expanded.
Horizon II
macro (6xCTU2)


X
M
U
X
Horizon II
macro (6xCTU2)


Horizonmacro
(6 x CTU)


F
M
U
X
E1
Horizon II macro, expanded to a Horizon II macro and a Horizonmacro.
Expansion configuration (cont)
Horizon II
macro (6xCTU2)


X
M
U
X
Horizonmacro
(6 x CTU)


F
M
U
X
F
M
U
X
F
M
U
X
Horizonmacro
(6 x CTU)


E1
Horizonmacro controlling a Horizon II macro and another Horizonmacro.
M-Cell 6 controlling a Horizon II macro and a Horizonmacro.
Horizon II
macro (6xCTU2)


X
M
U
X
M-Cell 6
(6 x TCU)


F
M
U
X
F
M
U
X
F
M
U
X
Horizonmacro
(6 x CTU)


E1
Compact Transceiver Unit
(CTU2)
CTU2
Compact Transceiver Unit (CTU2)
Compact Transceiver Unit ( CTU2)
Single Density Mode High Power 63W (48dbm) 900MHz
50W (47dbm) 1800MHz
Normal Power 20W (43dbm) 900MHz
16W (42dbm) 1800MHz

Double Density Mode Normal Power 20W (43dbm) 900MHz
16W (42dbm) 1800MHZ


CTU2 backwards compatibility
Compact Transceiver Unit 2 (CTU2)

Backwards compatible with Horizonmacro Cabinet
(with minor limitations).

Requires the correct software ( GSR6 HII)
Can NOT support the CCB controller function
O/P power reduced when in Double Density Mode
BBH not supported

Compact Transceiver Unit 2 (CTU2)
TRANSMIT
RF OUT
TEST
INTERFACE
TTY
INTERFACE
Radio
Status
LED
Tx
Status A
LED
Tx
Status B
LED
VCAT
INTERFACE
Surf2 to CTU2 Interface
CTU2 to SURF2 interconnection
Second SURF2 not supported
(4 branch diversity)
CTU2 DCS 1800 PA Diagram
F
PA Branch 1
PA Branch 2
PA Temp.
2
nd
Temp.
Fwd Power Detect A
Fwd Power Detect B
Rev Power Detect
Phase Adjust
Branch B VVA
Branch A VVA
PA Mode Switches
PA Pad Switches
Basic Block Diagram TX (PA only)
RF Equipment
RF Equipment
Surf2
Sectorized Universal Receiver Front end (SURF2)
Surf2 Functional Diagram
SURF2 Functional diagram
3x Ant ports with 2x Branches each
Expansion
Cabinet TX Blocks
Transmitter RF Blocks
RF Blocks:
DUP - Duplexer
HCU - Hybrid Combiner Unit
DHU - Dual Hybrid combiner Unit
Connecting Panels
Blanking Plate
Feedthrough plate
Transmitter Blocks
Blanking Plate
Blanking Plate
Used to control the Air flow within the cabinet
Feedthrough Plate
Feedthrough Plate
Duplexer (DUP)
Duplexer- DUP

Connects a single CTU2 to
a single Tx/Rx Antenna.

Typical 1db loss.
DUP Functional Diagram
DUP Block diagram
VSWR
CTU2





DUP
Rx Filter
Tx Filter
VSWR
Monitor
Alarm
Board
Antenna
To SURF
Tx
The Antenna VSWR
monitoring function is used to
detect faults in antennas or
antenna path connections.

VSWR Monitoring
Part of the Tx power
Power Indicator
Hybrid Combiner Unit (HCU)
Hybrid Combiner Unit - HCU
HCU
Used to connect 2x
CTU2 via a Hybrid
Typical 3-4db loss
HCU Functional Diagram
HCU- Block diagram
Typical 3-4db loss
Dual Hybrid Combiner (DHU)
Dual Hybrid Combiner Unit - DHU
Typical 6 db loss
DHU Functional Diagram
Dual Hybrid Combiner Unit - DHU
6dbs typical
loss
Software and Database Requirements
Software and Database Requirements

New Cabinet Type - horizonmacro2 (24)
- horizonmacro2_ext (25)

Equipping the DRI Density is required
Single or Double
(called the associated DRI)

Setting CTU2 to High Power (max_tx_bts= -1)
MMI Command : equip <site number> DRI
Enter the 1st and 2nd DRI id: 0 0
Enter the density of this DRI: SINGLE
Enter the cabinet identifier: 0
Enter the type of connection to the BTP: master
Enter the port to which the TCU is connected: 0
Enter the 1st and 2nd RTF id:
Enter the GSM cell ID where the DRI appears: 1 2 3 9 9 4 21
Enter antenna select number for this cell: 1
Does this DRI use tuneable combining: no
Enter diversity flag for this DRI: 1
Enter the fm cell type: 4


Equipping a DRI Single Density
New line within
the command
MMI Command: equip <site number> DRI
Enter the 1st and 2nd DRI id: 0 0
Enter the density of this DRI: DOUBLE
Enter the 2nd DRI id of the associated DRI: 1
Enter the cabinet identifier: 0
Enter the type of connection to the BTP: master
Enter the port to which the TCU is connected: 0
Enter the 1st and 2nd RTF id:
Enter the GSM cell ID where the DRI appears: 1 2 3 9 9 4 64
Enter antenna select number for this cell: 1
Enter diversity flag for this DRI: 1
Enter the fm cell type: 4


Equipping a DRI Double Density
Associated DRI Number
CTU2 High Power parameter

DRI equipped in SINGLE Density Mode only

Parameter max_tx_bts = -1 (per cell basis)
Parameter tx_power_cap =1 (DCS1800 only)

RF power EGSM900 DCS1800
63W (48dbm) 50W (47dbm)
RETURN to Menu

Das könnte Ihnen auch gefallen