Sie sind auf Seite 1von 112

Effective August, 2008

Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 1
F1-1
F
Page Description
2, 3 Mercmaster III Family Tree
2-22 Mercmaster III HID Low Profile
Lighting Fixtures
23-54 Mercmaster III HID 50-250W
Lighting Fixtures
55-70 Mercmaster III-400 HID
Lighting Fixtures
99, 100 Wallmaster I/2
101-105 Zone 2 Areamaster 250/400
106-121 Mercmaster II HID Lighting Fixtures
122-130 Mercmaster Jr. Lighting Fixtures
131, 132 Stylmaster HID Lighting Fixtures
133-135 Corroflood 250/400 Floodlights
136 PCD2 Series Photocontrol
HID Lighting:
Enclosed and Gasketed
Corroflood 250/400
Mercmaster Jr.
Stylmaster
Mercmaster II
Mercmaster III
50-250W
Mercmaster
III-400
Mercmaster III
Low Profile
Effective August, 2008
Copyright 2008
PAGE 2
800-621-1506
www.appletonelec.com

F1-2
F
Cone
Pendant Mount
KPCH75
KPCH100
Ceiling Mount
KPC75
KPC100
Pendant Mount
KPA75
KPA100
Flexible
Pendant Mount
KPAF75
KPAF100
Standard Dome
KR2-ST
Standard Dome
KR2-ST
Standard Dome
CMR-4ST*
Metal Halide
100W Max
Lamp Extender
30 Angle
KR2-AN
30 Angle
KR2-AN
KGU2
Fluorescent
Globe Guard
Three-Way Exit Sign
CJEXR
KGU1
HID Globe
Guard
KGU2
Globe Guard
KRG2
Refractor Guard
30 Angle
CMR-4AN
POLYMERIC
REFRACTORS
NEMA 2 LPRF-2CP
NEMA 3 LPRF-3CP
NEMA 4 LPRF-4CP
NEMA 5 LPRF-5CP
GLASS REFRACTORS
NEMA 1 LPG-R1
NEMA 3 LPG-R3
NEMA 5 LPG-R5
HID GLASS GLOBE
Clear VPGL-1HR
Amber VPGL-1AM
Blue VPGL-1BL
Green VPGL-1GR
Red VPGL-1RE
GLASS GLOBE
Fluorescent
Clear VPGL-2HR
Amber VPGL-2AM
Blue VPGL-2BL
Green VPGL-2GR
Red VPGL-2RE
GLASS GLOBES
Clear VPGL-2HR
Amber VPGL-2AM
Blue VPGL-2BL
Green VPGL-2GR
Red VPGL-2RE
5-1/2"
5-1/2"
7-3/4"
Fluorescent
Metal Halide
100W Max.
(Lamp Extender
not required)
9.25"
5-5/8"
6-3/4"
8"
8-1/2"
5-3/4"
DIA.
6-5/8"
13-1/4"
11-3/8"
5-11/16"
EXIT
KPB SERIES
50W-150W HPS
100W-250W MH
100W-250W MV
175W, 200W PSMH
Mogul Base
MLBR SERIES
35W-150W HPS
50W-175W MH
50W-100W MV
150W, 175W PSMH
Med. Base
26-84W Fluorescent
(Section F3)
MLBG SERIES
35W-150W HPS
50W-100W MH
50W-100W MV
150W, 175W PSMH
Med. Base
26-84W Fluorescent
(Section F3)
POLYMERIC
REFRACTORS
NEMA 2 LPRF-2CP
NEMA 3 LPRF-3CP
NEMA 4 LPRF-4CP
NEMA 5 LPRF-5CP
Mercmaster

III Family Tree


* Consult factory if used with KPST or KPWB Mounting Hoods.
MLBG SERIES
35 W-150 W HPS
50 W-100 W MH
150 W, 175 W PSMH
Med. Base
26-84 W Fluorescent
(Section F3)
MLBR SERIES
35 W-150 W HPS
50 W-175 W MH
150 W, 175 W PSMH
Med. Base
26-84 W Fluorescent
(Section F3)
KPB SERIES
50 W-150 W HPS
100 W-250 W MH
175 W, 200 W PSMH
Mogul Base
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 3
F1-3
F
Mercmaster

III Family Tree


* Consult factory if used with KPST or KPWB Mounting Hoods.
KPBR SERIES
50 W-150 W HPS
100 W-250 W MH
175 W, 200 W PSMH
Mogul Base
KPB400 SERIES
250 W-400 W HPS
400 W MH
250 W, 320 W,
350 W, 400 W PSMH
Mogul Base
KPR-4HB
16 Lens Enclosed
Reflector
GLASS GLOBE
Clear VPGL-3HR
(for 100 W HPS only)

25 Stanchion Mount
KPS125
KPS150

90 Stanchion Mount
KPST125
KPST150

Wall Mount
KPWB75
KPWB100
NEMA 2 KPRF400-2
NEMA 3 KPRF400-5
Effective August, 2008
Copyright 2008
PAGE 4
800-621-1506
www.appletonelec.com

F1-4
F
Mercmaster

III Low Profile


Enclosed and Gasketed Fixtures for Hazardous and Adverse Locations
High Pressure Sodium, Metal Halide, and Pulse Start Metal Halide luminaires.
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Applications
Enclosed and gasketed fixtures
suitable for use in marine and wet
locations, and in a wide range of
industrial, chemical processing and
other areas where flammable gases
and vapors or combustible dusts are
present under conditions defined
by the National Electrical Code as
Class I, Div. 2; Class II, Div. 1 and
2; and Class III. For Zone 2, the
method of protection is AEx nA nR
Restricted Breathing/Nonsparking.
In areas of low clearance, low ceil-
ing heights or where fixture weights
must be minimized.
Suited for use in non-hazardous loca-
tions where severe weather condi-
tions, excessive moisture, dirt, dust,
corrosive atmosphere or high ambient
temperatures are encountered.
Typical applications include pulp
and paper mills, processing plants,
chemical plants, oil refineries,
foundries, manufacturing plants,
storage areas, waste and sewage
treatment, parking garages and
other areas where dust, water, dirt
and rough usage are a problem.
Features
Compact light-weight low profile
design is suited for low mounting
heights in conjunction with lower
wattage fixtures.
Modular design allows scores of fixture
component combinations to meet instal-
lation and lighting needs. Uses same
mounting hoods and optical accesso-
ries as Mercmaster III.
A choice of heat-resistant prismatic
glass refractors (NEMA I, III or
V) or heat-resistant globes which
thread directly into ballast housing.
Photometrics available upon request
consult factory.
Standard dome or 30angle reflec-
tors made of fiberglass reinforced
white polyester. Highly resistant to
corrosive atmospheres.
Fixture housing, mounting hoods
and guards are copper-free cast alu-
minum with baked epoxy finish. All
exposed hardware is stainless steel.
Accommodates medium base lamps.
A wide range of voltages available (120
to 600 volt) and ballast types (reactor,
CWA, CWI and Super CWA).
Lamp type and watts:
HPS 35 W-150 W
MH 50 W-100 W (Globe version)
MH 50 W-175 W (Refractor version)
PSMH 150 W, 175 W
Medium Base Lamps
Hinge has high lip for added safety
during installation and servicing.
Hinge and bolt construction assures
360 compression at all points on
ballast housing gasket for positive
sealing. Swing away design of cap-
tive bolt and nut simplifies servicing.
All Mercmaster III mounting hoods
have provision for easy field installa-
tion of fuses in fixtures (see fuse kit
listings in this catalog section).
Fixtures are for use in Class I, Zone
2 hazardous locations.
The AEx nA nR factory-sealed
Mercmaster III prevents vapors
and gases from entering the globe
chamber. There are no seals or
putty required which will reduce in-
stallation time and installation errors.
Standard Materials
Mounting hoods, bodies and guard:
copper-free cast aluminum.
All hardware and catch assemblies:
stainless steel.
Reflectors: fiberglass-reinforced
white polyester.
Globes and Refractors: heat-resis-
tant prismatic glass.
Standard Finishes
Mounting hoods, bodies and
guards: baked gray epoxy-clad fin-
ish, electrostatically applied for com-
plete uniform protection.
Low Profile Mercmaster III
with Refractor
Low Profile Mercmaster III
with Prismatic Globe and Guard
Fixtures equipped with quartz auxiliary lamp do not comply with UL requirements and are not suitable for use in classified locations.
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 5
F1-5
F

Smart Starter (for HPS fixtures


only) incorporates a 1-1/2-minute
timer and performs as a conven-
tional starter to normally start lamp.
Removes itself from circuit if lamp
burns out or is removed from socket.
Eliminates starter failures caused by
prolonged operation with cycling or
failing lamps and simplifies finding
their location, reducing maintenance
and repair costs. Available for all
HPS fixtures. Add suffix -S.

Guards with gray epoxy painted to


match fixtures, supplied with stain-
less steel screws. Add suffix -G
before voltage suffix.

Reflectors are available as stan-


dard dome and 30angle polyester.
Order separately.

Photocells for classified and non-


classified use. See page F1-14.
Compliances
UL Listed
UL 1598A, UL 844, Marine Type
Electric Fixtures Outside Type (Salt
Water)

UL 2279
CSA Certified
Class I, Div. 2, Groups A,B,C,D
Class I, Zone 2 AEx nA nR IIC
Class II, Div. 1 and 2; Groups E,F,G
Class III
NEMA 4X; IP66
CSA 4X
Simultaneous Exposure
Class I, Div. 2; Class II, Div. 1
* Compliance data varies for specific fixtures.
Consult Appleton regarding suitability of specific
fixtures for a particular application.
Options
AEx nA nR fixtures are available with
a Class I, Zone 2. Add suffix -Z2.
Hot Restrike to restrike HPS lamp
immediately when power is restored
after a momentary power interrup-
tion. Add suffix -R.
Quartz Auxiliary comes to full bright-
ness immediately and remains lit
until the HID lamp attains 60-70%
of full illumination. Quartz Auxiliary
supplied with relay switch and sock-
et to accept 120 V quartz double-
contact bayonet base lamp (not
included). Add suffix -E.

Smart Hot Restrike will immediately


restrike HPS lamp when power is
restored after a momentary power
interruption. The smart function re-
moves the hot restrike ignitor from
the circuit if the lamp burns out or is
removed from the socket. Eliminates
starter failures caused by prolonged
operation with cycling or failing
lamps. Add suffix -SR.
Mercmaster

III Low Profile


Enclosed and Gasketed Fixtures for Hazardous and Adverse Locations
High Pressure Sodium, Metal Halide, and Pulse Start Metal Halide luminaires.
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Effective August, 2008
Copyright 2008
PAGE 6
800-621-1506
www.appletonelec.com

F1-6
F
Mercmaster

III Low Profile


Enclosed and Gasketed Fixtures for Hazardous and Adverse Locations
High Pressure Sodium, Metal Halide, and Pulse Start Metal Halide luminaires.
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
**Other voltages, frequencies available consult factory. Voltages shown are limited to specific combinations; refer to following pages.
Polymeric Refractor suitable for Class II, Groups F & G, NEMA 4X and Marine Type Electric Fixtures Outside Type (Salt Water) only (100 W MH Max.).
Reflectors ordered separately.
SERIES:
ML - Mercmaster
Low Profile
MOUNTING:
A - Pendant (rigid mounting)
C - Ceiling
D - Pendant Cone Hood
F - Pendant (flexible
mounting)
R - 90Stanchion
S - 25Stanchion
W - Wall
LAMP TYPE:
H - Metal Halide
I - Incandescent
L - High Pressure
Sodium
P - Pulse Start Metal
Halide
WATTAGE:
10 - 100 W all lamp types
15 - 150 W HPS, PSMH and
60-150 W max.
Incandescent
17 - 175 W MH, PSMH
(MH Glass Refractor
Only)
35 - 35 W HPS
50 - 50 W MH & HPS
70 - 70 W MH & HPS
HUB SIZE:
2 - 3/4 NPT
3 - 1 NPT
4 - 1-1/4 NPT
stanchion
5 - 1-1/2 NPT
stanchion
OPTICAL ASSEMBLY:
G1 - Globe
J1 - NEMA I Glass Refractor
J3 - NEMA III Glass Refractor
J5 - NEMA V Glass Refractor
P2 - NEMA II Polymeric Refractor
P3 - NEMA III Polymeric Refractor
P4 - NEMA IV Polymeric Refractor
P5 - NEMA V Polymeric Refractor
GUARD
OPTIONS:
G - Cast Guard
N - No Guard
OPTIONS:
E - Emergency
Quartz
F - Fuse Kit
(Specify Voltage)
R - Hot Restrike
S - Smart Starter
SR - Smart Hot Restrike
PC12 - Photocontrol 120 V
PC20 - Photocontrol 208 V
PC24 - Photocontrol 240 V
PC27 - Photocontrol 277 V
CATALOG NUMBERING GUIDE FOR MERCMASTER III LOW PROFILE HID LUMINAIRES
ML A L 15 2 G1 G MT R Z2
SUFFIX:
Z2 - Zone 2
suffix
(required for
AEx nA nR
rating)
Ordering Information:
Order using catalog numbering guide below or select catalog number from tables on following pages.
VOLTAGE**
MT 120/208/240/277, 60Hz
48 480, 60Hz
H1 120, 60Hz
FM 127/220, 60Hz
FA 220, 60Hz
5MT 120/208/240/277/480,
60Hz
AM 127/220, 60Hz
GK 220/240, 50Hz
GP 120/220/240, 50Hz
XQ 120/230, 50Hz
LB
Incandescent, 120V,
60Hz
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 7
F1-7
F
High Temperature Sockets
Medium base high-temperature
porcelain sockets.
Aluminum Inner Reflector
Solid aluminum inner reflector
(for refractor ballast housings only)
improves photometric efficiency.
Globe Chamber
Completely sealed from the ballast
housing and outside vapors/air (nR).
Stainless Steel
Latch Assembly
Captive, stainless
steel latch assembly
bolt and nut closes
securely, resists
attack of corro-
sive atmospheres.
Swing-away design
simplifies servicing.
Fuses
Two screws secure fuse kit to
mounting boss in any Mercmaster
mounting hood. Fuse included.
Epoxy Finish
Ballast housing, hoods and guards are
copper-free aluminum with epoxy pow-
der coat finish.
Stainless Steel Inserts
Ballast bodies have stainless steel
threaded inserts to receive stainless
steel screws for reflectors and guard.
Prevents "freezing, allowing guards
and reflectors to be easily removed and
replaced at any time, without damage
to the housing.
Cooler Operating Cone Hood
Larger sloped surface sheds dusts, dirt
and combustible fibers providing better
heat dissipation.
Electrical Protection
Ground wire provided to bond
mounting hood to ballast housing.
Vented Reflectors
Reflectors are thick, tough fiberglass-
reinforced white polyester, vented for
cooler operation. Quickly attach with
furnished stainless steel screws.
Ballast Assembly
Utilizing non-sparking components
avoiding the ignition of gases or vapors
that may be present (nA).
Hood/Ballast Gasket
Silicone rubber gasket seals out
moisture, dirt and dust. Stays flexible,
withstands high temperatures. Closure
design assures uniform gasket
compression.
Terminal Blocks (Zone 2)
A seven-point terminal block is provided
to facilitate wiring. Terminal block
accommodates wire size ranging from
#8 to #24 AWG.
"Safety" High Hinge
Extra-high hinge
provides additional
protection against
accidental ballast
housing disen-
gagement during
installation or
maintenance.
Prismatic Glass Globes and Refractors
Heat-resistant globes and refractors
thread directly into ballast housing and
seal against a high-temperature
silicone rubber gasket.
Mercmaster

III Low Profile


Enclosed and Gasketed Fixtures for Hazardous and Adverse Locations
Photocell
Available for all fixtures except cone and
ceiling mount. Installs through knock-out
in mounting hood. Provides continuous
ON-OFF dusk-to-dawn control.
Effective August, 2008
Copyright 2008
PAGE 8
800-621-1506
www.appletonelec.com

F1-8
F
Mercmaster

III Low Profile


Thermal Performance: Class I, Div. 2; Class II, Div. 1; and simultaneous
exposure to hazardous conditions on both classifications
Temperature identification numbers of Mercmaster III Low Profile Fixtures
T Numbers Represent the Maximum Lamp Temperature for Class I, Div. 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Div. 1 Locations.
Lamp
Supply
Wire
Temp.
(C)
Ambient
Temp.
(C)
Class I, Div.2
Class II, Div. 1
Groups E, F and G
Simultaneous Exposure
Class I, Div. 2 / Class II, Div. 1
Watts Type Globe
Globe &
Reflector Refractor Globe
Globe &
Reflector Refractor Globe
Globe &
Reflector Refractor
90 40 T3C T3C T3C T5 T5 T6 T3A T3A T3A
35 HPS 90 55 T3A T3A T3C T4A T4A T5 T3 T3 T3
90 65 T3A T3A T3C T4A T4A T5 T2D T2D T3
90 40 T3 T3 T3B T4A T4A T5 T3 T3 T3
50 HPS 90 55 T3 T3 T3A T4A T4A T4A T2D T2D T2D
90 65 T3 T3 T3A T4 T4 T4 T2C T2C T2C
90 40 T3 T3 T3 T4 T4 T5 T2B T2B T2D
70 HPS 90 55 T2D T2D T3 T3C T3C T4A T2B T2B T2C
90 65 T3 T4A T2B
90 40 T2C T2C T2D T4 T4 T4A T2B T2B T2B
100 HPS 90 55 T2B T2B T2C T3C T3C T4 T2A T2A T2A
90 65
150 HPS 90 40 T2A T2A T2B T3A* T4 325 T2
90 40 T3 T3 T3A T4A T4A T6 T2D T2D T3
50 MH 90 55 T3 T3 T3 T4 T4 T5 T2C T2C T2D
90 65 T3 T3 T3 T4 T4 T4A T2B T2B T2D
90 40 T3 T3 T3 T3C T3C T4A T2B T2B T2C
70 MH 90 55 T2D T2D T3 T3C T3C T4A T2A T2A T2B
110 65 T3 T4 T2B
100 MH
90 40 T2A T2A T2B T3B T3B T4A T2 T2 T2A
90 55 T2A T2A T2B T3A* T3A* T4 T1 T1 T2
175 MH 110 40 325 T3B T1
150 PSMH 110 40 350 350 325 T3B T1
175 PSMH 110 40 350 350 325 T3B T1
90 40 T3B T3B T3C
60 Inc. 90 55 T3A T3A T3C
90 65 T3A T3A T3C
90 40 T3 T3 T3
100 Inc. 90 55 T3 T3 T3
90 65 T2D T2D T3
90 40 T2D T2D T3
150 Inc. 90 55 T2B T2B T2D
90 65 T2B T2B T2D
T
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
Range
(C)
351-450 326-350 301-325 281-300 261-280 231-260 216-230 201-215 181-200 166-180 161-165 136-160 121-135 101-120 86-100 85
* T numbers are for Groups E and F only.
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 9
F1-9
F
Mercmaster

III Low Profile


Thermal Performance: Class I, Zone 2, AEx nA nR IIC IP66, NEMA 4X
Temperature identification numbers of Mercmaster III Zone 2 Low Profile Fixtures
Lamp Supply
Wire
C
Ambient
Temp.
C
Class I, Zone 2 AEx nA nR IIC
Watts Type Globe Globe w/Reflector Refractor
35 HPS
90 40 T6 T6 T6
90 55 T6 T6 T6
90 65 T5 T5 T5
50 HPS
90 40 T6 T6 T6
90 55 T5 T5 T5
90 65 T4 T4 T5
70 HPS
90 40 T5 T5 T5
90 55 T4 T4 T4
90 65 T4
100 HPS
90 40 T4 T4 T4
90 55 T4 T4 T4
65
150 HPS 90
40 T4 T4 T4
55
65
50 MH
90 40 T5 T5 T6
90 55 T5 T5 T6
90 65 T4 T4 T5
70 MH
90 40 T5 T5 T6
90 55 T4 T4 T6
110 65 T5
100 MH
90 40 T4 T4 T6
90 55 T4 T4 T4
65
175 MH 110
40 T3
55
65
150 PSMH 110
40 T3 T3 T4
55
65
175 PSMH 110
40 T3 T3 T4
55
65
T Numbers represent the maximum surface temperature for luminaries with AEx nA nR rating:
T Number T1 T2 T3 T4 T5 T6
Temp. Range (C) 301-450 201-300 136-200 101-135 86-100 85
The T number is established by separately determining the maximum temperature of the globe surface and ballast compartment. The hotter of the two is taken
to determine the T number for the overall xture.
Effective August, 2008
Copyright 2008
PAGE 10
800-621-1506
www.appletonelec.com

F1-10
F
Mercmaster

III Low Profile


Enclosed and Gasketed Fixtures for Hazardous and Adverse Locations
High Pressure Sodium 35 W150 W
High Power Factor (min. P.F. 90%). Medium base lamps.
UL Listed
CSA Certified
Simultaneous Exposure
Class I, Div. 2; Class II, Div. 1
Class I, Div. 2; Groups A,B,C,D
Class I, Zone 2 AEx nA nR IIC
Class II, Div. 1 and 2; Groups E,F,G
Class III
UL 1598A, UL 844, Marine Type Electric
Fixtures Outside Type (Salt Water),
UL 2279
NEMA 4X; IP66
CSA 4X
Shown with Globe
Shown with Refractor
Shown with Globe and Optional Guard
Hub
Size
(Inches)
Catalog Numbers
Type
Mounting
Lamp
Type
Lamp
Watts
With
Globe
With Type V
8 Refractor
Pendant
One Hub,
Rigid Mounting
HPS 35 3/4 MLAL352G1N MLAL352J5N
1 MLAL353G1N MLAL353J5N
HPS 50 3/4 MLAL502G1N MLAL502J5N
1 MLAL503G1N MLAL503J5N
HPS 70 3/4 MLAL702G1N MLAL702J5N
1 MLAL703G1N MLAL703J5N
HPS 100 3/4 MLAL102G1N MLAL102J5N
1 MLAL103G1N MLAL103J5N
HPS 150 3/4 MLAL152G1N MLAL152J5N
1 MLAL153G1N MLAL153J5N
Pendant Cone
One Hub,
Rigid Mounting
HPS 35 3/4 MLDL352G1N MLDL352J5N
1 MLDL353G1N MLDL353J5N
HPS 50 3/4 MLDL502G1N MLDL502J5N
1 MLDL503G1N MLDL503J5N
HPS 70 3/4 MLDL702G1N MLDL702J5N
1 MLDL703G1N MLDL703J5N
HPS 100 3/4 MLDL102G1N MLDL102J5N
1 MLDL103G1N MLDL103J5N
HPS 150 3/4 MLDL152G1N MLDL152J5N
1 MLDL153G1N MLDL153J5N
Ceiling
Five Hubs,
Four Close-up
Plugs
HPS 35 3/4 MLCL352G1N MLCL352J5N
1 MLCL353G1N MLCL353J5N
HPS 50 3/4 MLCL502G1N MLCL502J5N
1 MLCL503G1N MLCL503J5N
HPS 70 3/4 MLCL702G1N MLCL702J5N
1 MLCL703G1N MLCL703J5N
HPS 100 3/4 MLCL102G1N MLCL102J5N
1 MLCL103G1N MLCL103J5N
HPS 150 3/4 MLCL152G1N MLCL152J5N
1 MLCL153G1N MLCL153J5N
For Flexible Pendant Mount, change A to F in catalog number.
To order xture with NEMA Type I or NEMA Type III refractor, change nal digit 5 in catalog number to 1 or 3.
Add the following voltage and frequency designation before Z2 sufx:
Sufx Voltage Frequency Notes Sufx Voltage Frequency Notes
MT 120/208/240/277 60 Hz All except 35 W HPS FA 220 60 Hz 70 W, 100 W, 150 W HPS
48 480 60 Hz All except 35 W, 50 W HPS GK 220/240 50 Hz 50 W HPS
H1 120 60 Hz 35 W HPS GP 120/220/240 50 Hz 70 W, 100 W, 150 W HPS
FM 127/220 60 Hz 50 W HPS LB 120V 60 Hz 60-150 W Incandescent
Add Z2 sufx for factory-sealed non-sparking/restricted breathing protection (Aex nA nR).
For fixtures with guards, substitute a G for the N before adding voltage suffix. See following pages for accessory ordering information
For 150W HPS xtures, use S-55 lamp type only.
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 11
F1-11
F
Shown with Globe and Optional Guard
Mercmaster

III Low Profile


Enclosed and Gasketed Fixtures for Hazardous and Adverse Locations
High Pressure Sodium 35 W150 W
High Power Factor (min. P.F. 90%). Medium base lamps.
Shown with Refractor and Optional Guard
Shown with Refractor and Optional Guard
Hub
Size
(Inches)
Catalog Numbers
Type
Mounting
Lamp
Type
Lamp
Watts
With
Globe
With Type V
8 Refractor
Wall
Five Hubs,
Four Close-Up
Plugs
HPS 35 3/4 MLWL352G1N MLWL352J5N
1 MLWL353G1N MLWL353J5N
HPS 50 3/4 MLWL502G1N MLWL502J5N
1 MLWL503G1N MLWL503J5N
HPS 70 3/4 MLWL702G1N MLWL702J5N
1 MLWL703G1N MLWL703J5N
HPS 100 3/4 MLWL102G1N MLWL102J5N
1 MLWL103G1N MLWL103J5N
HPS 150 3/4 MLWL152G1N MLWL152J5N
1 MLWL153G1N MLWL153J5N
25 Stanchion
One Hub
HPS 35 1-1/4 MLSL354G1N MLSL354J5N
1-1/2 MLSL355G1N MLSL355J5N
HPS 50 1-1/4 MLSL504G1N MLSL504J5N
1-1/2 MLSL505G1N MLSL505J5N
HPS 70 1-1/4 MLSL704G1N MLSL704J5N
1-1/2 MLSL705G1N MLSL705J5N
HPS 100 1-1/4 MLSL104G1N MLSL104J5N
1-1/2 MLSL105G1N MLSL105J5N
HPS 150 1-1/4 MLSL154G1N MLSL154J5N
1-1/2 MLSL155G1N MLSL155J5N
90 Stanchion
One Hub
HPS 35 1-1/4 MLRL354G1N MLRL354J5N
1-1/2 MLRL355G1N MLRL355J5N
HPS 50 1-1/4 MLRL504G1N MLRL504J5N
1-1/2 MLRL505G1N MLRL505J5N
HPS 70 1-1/4 MLRL704G1N MLRL704J5N
1-1/2 MLRL705G1N MLRL705J5N
HPS 100 1-1/4 MLRL104G1N MLRL104J5N
1-1/2 MLRL105G1N MLRL105J5N
HPS 150 1-1/4 MLRL154G1N MLRL154J5N
1-1/2 MLRL155G1N MLRL155J5N
To order xture with NEMA Type I or NEMA Type III refractor, change nal digit 5 in catalog number to 1 or 3.
Add the following voltage and frequency designation before Z2 sufx:
Sufx Voltage Frequency Notes Sufx Voltage Frequency Notes
MT 120/208/240/277 60 Hz All except 35 W HPS FA 220 60 Hz 70 W, 100 W, 150 W HPS
48 480 60 Hz All except 35 W, 50 W HPS GK 220/240 50 Hz 50 W HPS
H1 120 60 Hz 35 W HPS GP 120/220/240 50 Hz 70 W, 100 W, 150 W HPS
FM 127/220 60 Hz 50 W HPS LB 120V 60 Hz 60-150 W Incandescent
Add Z2 sufx for factory-sealed non-sparking/restricted breathing protection (Aex nA nR).
For fixtures with guards, substitute a G for the N before adding voltage suffix. See following pages for accessory ordering information
For 150W HPS xtures, use S-55 lamp type only.
UL Listed
CSA Certified
Simultaneous Exposure
Class I, Div. 2; Class II, Div. 1
Class I, Div. 2; Groups A,B,C,D
Class I, Zone 2 AEx nA nR IIC
Class II, Div. 1 and 2; Groups E,F,G
Class III
UL 1598A, UL 844, Marine Type Electric
Fixtures Outside Type (Salt Water),
UL 2279
NEMA 4X; IP66
CSA 4X
Effective August, 2008
Copyright 2008
PAGE 12
800-621-1506
www.appletonelec.com

F1-12
F
Mercmaster

III Low Profile


Enclosed and Gasketed Fixtures for Hazardous and Adverse Locations
Metal Halide 50 W175 W; Pulse Start Metal Halide 150 W and 175 W
High Power Factor (min. P.F. 90%). Medium base lamps.
Shown with Globe and Optional Guard
Shown with Globe
Shown with Refractor
Hub
Size
(Inches)
Catalog Numbers
Type
Mounting
Lamp
Type
Lamp
Watts With Globe
With Type V
8 Refractor
Pendant
One Hub,
Rigid Mounting
MH 50 3/4 MLAH502G1N MLAH502J5N
1 MLAH503G1N MLAH503J5N
MH 70 3/4 MLAH702G1N MLAH702J5N
1 MLAH703G1N MLAH703J5N
MH 100 3/4 MLAH102G1N MLAH102J5N
1 MLAH103G1N MLAH103J5N
MH 175 3/4 MLAH172J5N
1 MLAH173J5N
PSMH 150 3/4 MLAP152G1N MLAP152J5N
1 MLAP153G1N MLAP153J5N
PSMH 175 3/4 MLAP172G1N MLAP172J5N
1 MLAP173G1N MLAP173J5N
Pendant Cone
One Hub,
Rigid Mounting
MH 50 3/4 MLDH502G1N MLDH502J5N
1 MLDH503G1N MLDH503J5N
MH 70 3/4 MLDH702G1N MLDH702J5N
1 MLDH703G1N MLDH703J5N
MH 100 3/4 MLDH102G1N MLDH102J5N
1 MLDH103G1N MLDH103J5N
MH 175 3/4 MLDH172J5N
1 MLDH173J5N
PSMH 150 3/4 MLDP152G1N MLDP152J5N
1 MLDP153G1N MLDP153J5N
PSMH 175 3/4 MLDP172G1N MLDP172J5N
1 MLDP173G1N MLDP173J5N
Ceiling
Five Hubs,
Four Close-up
Plugs
MH 50 3/4 MLCH502G1N MLCH502J5N
1 MLCH503G1N MLCH503J5N
MH 70 3/4 MLCH702G1N MLCH702J5N
1 MLCH703G1N MLCH703J5N
MH 100 3/4 MLCH102G1N MLCH102J5N
1 MLCH103G1N MLCH103J5N
MH 175 3/4 MLCH172J5N
1 MLCH173J5N
PSMH 150 3/4 MLCP152G1N MLCP152J5N
1 MLCP153G1N MLCP153J5N
PSMH 175 3/4 MLCP172G1N MLCP172J5N
1 MLCP173G1N MLCP173J5N
For Flexible Pendant Mount, change A to F in catalog number.
To order xture with NEMA Type I or NEMA Type III refractor, change nal digit 5 in catalog number to 1 or 3.
Add the following voltage and frequency designation before Z2 sufx:
Suffix Voltage Frequency Notes Suffix Voltage Frequency Notes
48 480 60 Hz All except 35 W, 50 W HPS & 50 W MH AM 127/220 60 Hz 175 W MH
FM 127/220 60 Hz 50 W HPS, 100 W MH GP 120/220/240 50 Hz 70 W, 100 W MH
5MT 120/208/240/277/480 60 Hz 175 W MH, 175 W PSMH XQ 120/230 50 Hz 175 W MH
LB 120V 60 Hz 60-150 W Incandescent
Add Z2 sufx for factory-sealed non-sparking/restricted breathing protection (Aex nA nR). See following pages for accessory ordering information
For fixtures with guards, substitute a G for the N before adding voltage suffix.
UL Listed
CSA Certified
Simultaneous Exposure
Class I, Div. 2; Class II, Div. 1
Class I, Div. 2; Groups A,B,C,D
Class I, Zone 2 AEx nA nR IIC
Class II, Div. 1 and 2; Groups E,F,G
Class III
UL 1598A, UL 844, Marine Type Electric
Fixtures Outside Type (Salt Water),
UL 2279
NEMA 4X; IP66
CSA 4X
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 13
F1-13
F
Shown with Refractor and Optional Guard
Shown with Globe and Optional Guard
Shown with Refractor and Optional Guard
Hub
Size
(Inches)
Catalog Numbers
Type
Mounting
Lamp
Type
Lamp
Watts With Globe
With Type V
8 Refractor
Wall
Five Hubs,
Four Close-Up
Plugs
MH 50 3/4 MLWH502G1N MLWH502J5N
1 MLWH503G1N MLWH503J5N
MH 70 3/4 MLWH702G1N MLWH702J5N
1 MLWH703G1N MLWH703J5N
MH 100 3/4 MLWH102G1N MLWH102J5N
1 MLWH103G1N MLWH103J5N
MH 175 3/4 MLWH172J5N
1 MLWH173J5N
PSMH 150 3/4 MLWP152G1N MLWP152J5N
1 MLWP153G1N MLWP153J5N
PSMH 175 3/4 MLWP172G1N MLWP172J5N
1 MLWP173G1N MLWP173J5N
25 Stanchion
One Hub
MH 50 1-1/4 MLSH504G1N MLSH504J5N
1-1/2 MLSH505G1N MLSH505J5N
MH 70 1-1/4 MLSH704G1N MLSH704J5N
1-1/2 MLSH705G1N MLSH705J5N
MH 100 1-1/4 MLSH104G1N MLSH104J5N
1-1/2 MLSH105G1N MLSH105J5N
MH 175 1-1/4 MLSH174J5N
1-1/2 MLSH175J5N
PSMH 150 1-1/4 MLSP154G1N MLSP154J5N
1-1/2 MLSP155G1N MLSP155J5N
PSMH 175 1-1/4 MLSP174G1N MLSP174J5N
1-1/2 MLSP175G1N MLSP175J5N
90 Stanchion
One Hub
MH 50 1-1/4 MLRH504G1N MLRH504J5N
1-1/2 MLRH505G1N MLRH505J5N
MH 70 1-1/4 MLRH704G1N MLRH704J5N
1-1/2 MLRH705G1N MLRH705J5N
MH 100 1-1/4 MLRH104G1N MLRH104J5N
1-1/2 MLRH105G1N MLRH105J5N
MH 175 1-1/4 MLRH174J5N
1-1/2 MLRH175J5N
PSMH 150 1-1/4 MLRP154G1N MLRP154J5N
1-1/2 MLRP155G1N MLRP155J5N
PSMH 175 1-1/4 MLRP174G1N MLRP174J5N
1-1/2 MLRP175G1N MLRP175J5N
Mercmaster

III Low Profile


Enclosed and Gasketed Fixtures for Hazardous and Adverse Locations
Metal Halide 50 W175 W; Pulse Start Metal Halide 150 W and 175 W
High Power Factor (min. P.F. 90%). Medium base lamps.
To order xture with NEMA Type I or NEMA Type III refractor, change nal digit 5 in catalog number to 1 or 3.
Add the following voltage and frequency designation before Z2 sufx:
Suffix Voltage Frequency Notes Suffix Voltage Frequency Notes
MT 120/208/240/277 60 Hz All except 35 W HPS AM 127/220 60 Hz 175 W MH
48 480 60 Hz All except 35 W, 50 W HPS & 50 W MH GK 220/240 50 Hz 50 W HPS
H1 120 60 Hz 35 W HPS GP 120/220/240 50 Hz 70 W, 100 W, 150 W HPS;
70 W, 100 W MH FM 127/220 60 Hz 50 W HPS, 100 W MH
FA 220 60 Hz 70 W, 100 W, 150 W HPS XQ 120/230 50 Hz 175 W MH
5MT 120/208/240/277/480 60 Hz 175 W MH, 175 W PSMH LB 120V 60 Hz 60-150 W Incandescent
Add Z2 sufx for factory-sealed non-sparking/restricted breathing protection (Aex nA nR). See following pages for accessory ordering information
For fixtures with guards, substitute a G for the N before adding voltage suffix.
UL Listed
CSA Certified
Simultaneous Exposure
Class I, Div. 2; Class II, Div. 1
Class I, Div. 2; Groups A,B,C,D
Class I, Zone 2 AEx nA nR IIC
Class II, Div. 1 and 2; Groups E,F,G
Class III
UL 1598A, UL 844, Marine Type Electric
Fixtures Outside Type (Salt Water),
UL 2279
NEMA 4X; IP66
CSA 4X
Effective August, 2008
Copyright 2008
PAGE 14
800-621-1506
www.appletonelec.com

F1-14
F
Hazardous Location Photocontrols
Factory-Sealed
Applications
Encapsulated photocontrol provides
automatic dusk-to-dawn lighting
control in Class I, Div. 2 locations.
Typical applications include walk-
ways, security areas and any other
outdoor lighting application.
For use with Mercmaster III Low
Profile, Mercmaster III, and Merc-
master III 400 Series Luminaires.
For remote mounting in FS Boxes.
Features
Factory-sealed design eliminates the
need for an explosionproof enclosure.
Can be easily installed in the field.
Solid state design for performance
and reliability.
Available for 120, 208, 240, or 277
volts.
35-400 W H.I.D. incandescent or
fluorescent, 50/60 HZ.
1000 V.A. Voltage/Ampere
Minimum time delay: 15 seconds to
eliminate nuisiance tripping.
Turns fixture on at 3 footcandles, off
at 8 footcandles.
Provided with (3) 18AWG stranded
leads 6 in length.
Will fit through standard 1/2
knockout.
Materials
Encapsulated with epoxy sealing
compound.
FS Cover: aluminum
Compliances
Class I, Div. 2, Groups A,B,C,D
UL Standards: 1604 Hazardous
(Classified) Locations
NEMA 4X
PCD2 Series Hazardous Location Photocontrol
For use in Class I, Div. 2, Groups A,B,C,D locations.
Class I, Div. 2,
Groups A,B,C,D
Maintains Class I, Div. 2
rating for Mercmaster III
Low Profile, Mercmaster III,
and Mercmaster III 400
Series Luminaires
NEMA 4X
Ordering Information
1.13
(2.87 cm)
0.69
(1.75 cm)
1.94
(4.92 cm)
1.19
(3.02 cm)
1.375
(3.49cm)
2.56
(6.50 cm)
Factory-installed Photocontrol
Suffix Designation* Voltage Range
PC120 120 V, 50/60 Hz
PC208 208 V, 50/60 Hz
PC240 240 V, 50/60 Hz
Mercmaster III wall mounting hood with
photocontrol installed shown PC277 277 V, 50/60 Hz
Add to fixture catalog after voltage; i.e.: KPWBL1075MTPC12.
Photocontrol in FS cover for use with FS/FD box (Section B)
Catalog Number Voltage Range
FSKA-PC120D2 120V, 50/60 Hz
FSKA-PC247D2 208-277V, 50/60 Hz
Supplied with two stainless steel screws.
For neoprene gasket, order catalog number FS-GKR-1N.
Photocontrol for field installation
Catalog Number Max. Current Voltage Range
PC120D2 8.3 A 120 V, 50/60 Hz
PC247D2 3.5 A 208-277 V, 50/60 Hz
Dimensions
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 15
F1-15
F
Mercmaster

III Low Profile


Mounting Hoods and Ballast Housings
Hoods and Ballast Housings are Copper-Free Cast Aluminum (less than 4/10 of 1%).
Add -S after voltage suffix for Smart Starter. Add -SR after voltage suffix for Smart Hot Restrike. Add -R after voltage suffix for ballast
body with Hot Restrike Ignitor.
Add -E after voltage suffix for ballast body with provision for Quartz Emergency Light. Not suitable for hazardous locations.
Mounting Hoods
Description Hub Size (Inches) Catalog Number
Pendant
One Hub,
Rigid Mounting
3/4 KPA-75
1 KPA-100
Pendant (Flexible)
One Hub,
Flexible Mounting
3/4 KPAF-75
1 KPAF-100
Pendant Cone
One Hub,
Rigid or Flexible Mounting
3/4 KPCH-75
1 KPCH-100
Ceiling
Five Hubs,
Four Close-Up Plugs
3/4 KPC-75
1 KPC-100
Wall
Five Hubs,
Four Close-Up Plugs
3/4 KPWB-75
1 KPWB-100
25 Stanchion
One Hub 1-1/4 KPS-125
1-1/2 KPS-150
90 Stanchion
One Hub 1-1/4 KPST-125
1-1/2 KPST-150
Ballast Bodies
Type
Lamp
Watts
Catalog Numbers Voltage Suffixes
For Globe For Refractor MT 48 H1 FM FA 5MT AM GK GP XQ LB
High Pressure Sodium 35 MLBG35L MLBR35L X
High Power Factor 50 MLBG50L MLBR50L X X X
(Min. P.F. 90%) 70 MLBG70L MLBR70L X X X X
100 MLBG10L MLBR10L X X X X
150 MLBG15L MLBR15L X X X X
Metal Halide 50 MLBG50H MLBR50H X
HX-High Power Factor 70 MLBG70H MLBR70H X X X
(Min. P.F. 90%) 100 MLBG10H MLBR10H X X X X
175 MLBR17H X X X X X
Pulse Start Metal Halide 150 MLBG15P MLBR15P X X
Super Constant Wattage 175 MLBG17P MLBR17P X X X
(Min. P.F. 90%)
Incandescent 60-150 MLBG15I MLBR15I X
Voltage: -MT 120/208/240/277
-FM 127/220
-AM 127/220
-XQ 120/230
-H1 120
-FA 220
-GK 220/240
-LB 120
-48 480
-5MT 120/208/240/277/480
-GP 120/220/240
Ballast Body for Glass
Globe or Polymeric
Refractor
Ballast Body for
Glass Refractor
Effective August, 2008
Copyright 2008
PAGE 16
800-621-1506
www.appletonelec.com

F1-16
F
Mercmaster

III Low Profile


Accessories and Replacement Parts
Fixtures with refractors are not UL Listed when used with reflectors.
* Consult factory if used with KPST or KPWB series mounting hoods.
Standard Dome
Glass Globe
Glass Refractor
Refractor Guard
Globe Gaskets
Polymeric Refractor
Globe Guard
30 Angle
Item Description Catalog Number
White Polyester Reectors
Furnished with stainless steel screws
For Globe Fixtures Standard Dome KR2-ST
30Angle KR2-AN
For Glass Refractor Fixtures Standard Dome CMR-4ST*
30 Angle CMR-4AN
Prismatic Glass Globes Heat-Resistant
Clear VPGL-1HR
Amber VPGL-1AM
Blue VPGL-1BL
Green VPGL-1GR
Red VPGL-1RE
Closed Prismatic Glass Refractors
All heat-resistant
NEMA Type I LPG-R1
NEMA Type III LPG-R3
NEMA Type V LPG-R5
Copper-Free Aluminum Guards
Globe Guard KGU1
Refractor Guard KRG2
Replacement Globe Gaskets Silicone Rubber
Globe Gasket VPGL-GK
Refractor Gasket KRF-GK
Closed Prismatic Polymeric Refractors
For use with MH lamps, 100 W max. 40 C max. ambient temperature.
Suitable for Class II, Div. 1 & 2,
Groups F & G, NEMA 4X,
UL 1598A Marine Type Electric Fixtures
Outside Type (Salt Water)
NEMA Type II LPRF-2CP
NEMA Type III LPRF-3CP
NEMA Type IV LPRF-4CP
NEMA Type V LPRF-5CP
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 17
F1-17
F
Mercmaster

III Low Profile


Dimensions and Weights
1
5
.2
7

9
.2
5

2
.0
0

1
2
.0
3

7
.5
9

2
5

SET SCREW
17.23
9.79
12.03
SET SCREW
17.00
10.93
12.03
Mercmaster III Low Profile Ballast and Accessory Weights
Globe Housing Ballast (Wt. Lbs.) Refractor Housing Ballast (Wt. Lbs.)
Mounting
Hoods
Wt.
Lbs.
Refractors, Globes,
Guards and Reflectors
Wt.
Lbs. Watts HPS MH PSMH HPS MH PSMH
35 7.25 6.00 Pendant 2.25 8 Glass Refractor 5.25
50 7.25 7.00 7.75 7.50 Pendant Cone 2.50 Glass Globe 3.75
70 8.25 7.75 8.75 8.25 Ceiling 3.00 Refractor Guard 1.00
75 Wall 4.00 Globe Guard 1.00
100 9.75 9.25 10.25 9.75 25 Stanchion 3.25 Standard Dome 2.50
150 10.75 10.75 11.25 11.25 90 Stanchion 3.75 30 Angle 2.50
175 11.00 11.25 11.50 Polymeric Refractor 2.43
Weights are approximate. Add 0.25 lb. for Quartz option.
Effective August, 2008
Copyright 2008
PAGE 18
800-621-1506
www.appletonelec.com

F1-18
F
Mercmaster

III Low Profile


Electrical Specifications and Fuse Kits for Field Installation
Electrical Specifications
C.W.A. Constant Wattage Autotransformer. HX-HPF High Reactance High Power Factor Autotransformer. Super C.W.A. Super Constant Wattage Autotransformer.
150 W HPS units equipped with ballasts to operate 55 V lamps only.
Line
Voltage
Type of
Ballast
Starting
Amps
Operating
Amps
Total
Watts
35-Watt High Pressure Sodium
120 R-HPF 0.78 0.38 46
50-Watt High Pressure Sodium
120 HX-HPF 0.58 0.58 64
208 HX-HPF 0.35 0.33 64
240 HX-HPF 0.30 0.29 64
277 HX-HPF 0.24 0.25 64
70-Watt High Pressure Sodium
120 HX-HPF 0.90 0.82 94
208 HX-HPF 0.50 0.48 94
240 HX-HPF 0.44 0.41 94
277 HX-HPF 0.35 0.36 94
480 HX-HPF 0.21 0.21 93
100-Watt High Pressure Sodium
120 HX-HPF 1.30 1.15 130
208 HX-HPF 0.76 0.67 130
240 HX-HPF 0.66 0.58 130
277 HX-HPF 0.60 0.50 130
480 HX-HPF 0.33 0.29 130
150-Watt High Pressure Sodium
120 HX-HPF 2.00 1.66 188
208 HX-HPF 1.16 0.96 188
240 HX-HPF 1.00 0.83 188
277 HX-HPF 0.88 0.75 188
480 HX-HPF 0.50 0.42 188
50-Watt Metal Halide
120 HX-HPF 0.87 0.60 67
208 HX-HPF 0.51 0.35 67
240 HX-HPF 0.47 0.30 67
277 HX-HPF 0.39 0.25 67
70-Watt Metal Halide
120 HX-HPF 0.80 0.85 95
208 HX-HPF 0.50 0.50 95
240 HX-HPF 0.43 0.43 95
277 HX-HPF 0.39 0.37 95
480 HX-HPF 0.19 0.23 95
100-Watt Metal Halide
120 HX-HPF 1.20 1.15 130
208 HX-HPF 0.70 0.66 130
240 HX-HPF 0.61 0.58 130
277 HX-HPF 0.55 0.50 130
480 HX-HPF 0.30 0.30 132
175-Watt Metal Halide
120 C.W.A. 1.30 1.80 210
208 C.W.A. 0.75 1.04 210
240 C.W.A. 0.65 0.90 210
277 C.W.A. 0.55 0.80 210
480 C.W.A. 0.35 0.45 210
Lamp
Watts
Fuse Quantity
Required
Fuse Kit Catalog Number
Volts HPS MH PSMH
35W 120 1 F2
50W 120 1 F5 F3
208 2 F3 F3
240 2 F3 F2
277 1 F2 F2
70W 120 1 F5 F4
208 2 F3 F3
240 2 F3 F3
277 1 F2 F2
480 2 F2 F1
75W 120 1
277 1
100W 120 1 F7 F6
208 2 F5 F4
240 2 F3 F3
277 1 F3 F3
480 2 F3 F2
150W 120 1 F10 F5
208 2 F5 F3
240 2 F5 F3
277 1 F5 F2
480 2 F3 F1
175W 120 1 F5 F5
208 2 F3 F3
240 2 F3 F3
277 1 F2 F2
480 2 F2 F2
Line
Voltage
Type of
Ballast
Starting
Amps
Operating
Amps
Total
Watts
150-Watt Pulse Start Metal Halide
120 Super C.W.A. 1.40 1.70 190
208 Super C.W.A. 0.80 1.00 190
240 Super C.W.A. 0.70 0.85 190
277 Super C.W.A. 0.60 0.75 190
480 Super C.W.A. 0.25 0.40 190
175-Watt Pulse Start Metal Halide
120 Super C.W.A. 1.10 1.80 208
208 Super C.W.A. 0.58 1.10 208
240 Super C.W.A. 0.51 0.90 208
277 Super C.W.A. 0.45 0.78 208
480 C.W.A. 0.25 0.50 210
Fuse Kit
Order fuses as a separate item by catalog number from right columns.
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 19
F1-19
F
* Photometric data is based on a fixture with a 150-
watt clear High Pressure Sodium lamp (16,000
lumen). For candlepower values of fixtures with
other HPS lamps, use the following multipliers: for
a 100 W (9,500 lumen) HPS lamp 0.594; for a
70 W (6,400 lumen) HPS lamp 0.40; for a 50 W
(4,000 lumen) HPS lamp 0.25. For candlepower
values of fixture with guard, multiply by 0.95.
Mercmaster

III Low Profile


Photometric Data
150-Watt High Pressure Sodium
Zone Lumens Total Luminaire Efficiency = 83%
REPORT NUMBER: ML15LG 0-10 28.58 CIE Type Semi-Direct
10-20 123.97
Plane
Spacing
Criteria
Lamps: 150 W High Pressure Sodium with Globe only*
20-30 304.16
30-40 513.64 0-180 3.9 Coefficients of Utilization Zonal Cavity Method
40-50 889.19 90-270 3.9 Effective Floor Cavity Reflectance 0.20
50-60 1299.53 Diagonal 3.7 % Ceiling Rcc 80 70 50 30 10 0
60-70 1506.73 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 1706.16 Zonal Lumen Summary 0 91 91 91 91 85 85 85 85 75 75 75 65 65 65 55 55 55 51
80-90 1800.53 Zone Lumens % Lamp % Fixture 1 77 71 66 61 72 66 61 57 57 53 49 48 45 42 40 37 35 31
90-100 1791.58 0-30 4563.72 2.9 3.4 2 68 59 51 45 63 55 48 42 46 41 36 39 34 31 32 28 25 21
100-110 1652.69 0-40 970.35 6.1 7.3 3 61 50 42 35 56 46 39 33 39 33 28 32 27 23 26 22 19 16
110-120 1311.22 0-60 3159.07 19.7 23.8 4 55 43 35 28 50 40 32 26 34 27 22 28 23 18 22 18 15 12
120-130 351.25 0-90 8172.49 51.1 61.5 5 50 38 29 23 46 35 27 21 29 23 18 24 19 15 19 15 12 9
130-140 5.14 90-120 4755.49 29.7 35.8 6 46 33 25 19 42 31 23 18 26 20 15 21 16 12 17 13 10 7
140-150 0.00 90-130 5106.74 31.9 38.4 7 42 30 22 16 38 27 20 15 23 17 13 19 14 10 15 11 8 6
150-160 0.00 90-150 5111.87 31.9 38.4 8 39 27 19 14 36 25 18 13 21 15 11 17 12 9 14 10 7 5
160-170 0.00 90-180 5111.87 31.9 38.5 9 36 24 17 12 33 22 16 11 19 13 9 16 11 8 13 9 6 4
170-180 0.00 0-180 13284.37 83.0 100.0 10 33 22 15 11 31 20 14 10 17 12 8 15 10 7 12 8 5 4
Zone Lumens Total Luminaire Effieciency = 73.2%
REPORT NUMBER: ML15LST 0-10 219.96 CIE Type Direct
10-20 683.41
Plane
Spacing
Criteria
Lamps: 150 W High Pressure Sodium with
Standard Dome Reflector*
20-30 1267.92
30-40 1613.68 0-180 1.64 Coefficients of Utilization Zonal Cavity Method
40-50 1967.79 90-270 1.64 Effective Floor Cavity Reflectance 0.20
50-60 2333.86 Diagonal 1.88 % Ceiling Rcc 80 70 50 30 10 0
60-70 2328.33 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 1118.52 Zonal Lumen Summary 0 87 87 87 87 85 85 85 85 81 81 81 78 78 78 75 75 75 73
80-90 174.91 Zone Lumens % Lamp % Fixture 1 79 75 71 68 77 73 70 67 70 67 65 67 65 63 64 62 61 59
90-100 1.23 0-30 2171.29 13.6 18.5 2 70 63 58 53 68 62 57 52 59 55 51 57 53 50 55 52 49 47
100-110 0.00 0-40 3784.97 23.7 32.3 3 63 54 48 42 61 53 47 42 51 46 41 49 44 40 47 43 40 38
110-120 0.00 0-60 8086.62 50.5 69.1 4 57 47 40 35 55 46 39 34 44 38 34 42 37 33 41 36 33 31
120-130 0.00 0-90 11708.37 73.2 100.0 5 52 41 34 29 50 41 34 29 39 33 28 37 32 28 36 31 28 26
130-140 0.00 90-120 1.23 0.0 0.0 6 48 37 30 24 46 36 29 24 35 29 24 33 28 24 32 27 24 22
140-150 0.00 90-130 1.23 0.0 0.0 7 44 33 26 21 42 32 26 21 31 25 21 30 25 21 29 24 20 19
150-160 0.00 90-150 1.23 0.0 0.0 8 41 30 23 18 39 29 23 18 28 22 18 27 22 18 26 22 18 16
160-170 0.00 90-180 1.23 0.0 0.0 9 38 27 21 16 37 27 20 16 26 20 16 25 20 16 24 19 16 14
170-180 0.00 0-180 11709.6 73.2 100.0 10 35 25 19 15 34 24 18 14 24 18 14 23 18 14 22 18 14 13
Effective August, 2008
Copyright 2008
PAGE 20
800-621-1506
www.appletonelec.com

F1-20
F
Zone Lumens Total Luminaire Effieciency = 68.4%
REPORT NUMBER: ML15LAN 0-10 168.01 CIE Type Direct
10-20 536.92
Plane
Spacing
Criteria
Lamps: 150 W High Pressure Sodium with
30 Angle Dome Reflector*
20-30 972.38
30-40 1342.99 0-180 2.3 Coefficients of Utilization Zonal Cavity Method
40-50 1625.08 90-270 2.0 Effective Floor Cavity Reflectance 0.20
50-60 1721.88 Diagonal 1.8 % Ceiling Rcc 80 70 50 30 10 0
60-70 1586.98 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 1369.71 Zonal Lumen Summary 0 80 80 80 80 78 78 78 78 74 74 74 70 70 70 66 66 66 64
80-90 995.76 Zone Lumens % Lamp % Fixture 1 70 66 62 58 68 64 60 57 60 57 54 57 54 52 54 52 50 48
90-100 461.94 0-30 1677.30 10.5 15.3 2 63 56 50 45 60 54 49 44 51 46 42 48 44 41 45 42 39 37
100-110 127.24 0-40 3020.29 18.9 27.6 3 56 48 41 36 54 46 40 35 44 38 34 41 37 33 39 35 32 30
110-120 27.54 0-60 6367.25 39.8 58.2 4 51 42 35 29 49 40 34 29 38 32 28 36 31 27 34 30 26 24
120-130 4.31 0-90 10319.70 64.5 94.3 5 47 37 30 24 45 36 29 24 34 28 23 32 27 23 30 26 22 20
130-140 2.68 90-120 616.71 3.9 5.6 6 43 33 26 21 41 32 25 20 30 24 20 28 23 19 27 22 19 17
140-150 0.00 90-130 621.02 3.9 5.7 7 39 29 23 18 38 28 22 18 27 21 17 26 21 17 24 20 16 15
150-160 0.00 90-150 623.70 3.9 5.7 8 37 26 20 16 35 26 20 15 24 19 15 23 18 15 22 18 14 13
160-170 0.00 90-180 623.70 3.9 5.7 9 34 24 18 14 33 23 18 14 22 17 13 21 17 13 20 16 13 11
170-180 0.00 0-180 10943.41 68.4 100.0 10 32 22 16 12 31 22 16 12 21 15 12 20 15 12 19 15 11 10
Zone Lumens Total Luminaire Effieciency = 77.6%
REPORT NUMBER: ML15LJ5 0-10 16.51 CIE Type Semi-Direct
10-20 135.03
Plane
Spacing
Criteria
Lamps: 150 W High Pressure Sodium with
8 Prismatic Glass Refracter NEMA Type V*
20-30 274.24
30-40 463.44 0-180 2.22 Coefficients of Utilization Zonal Cavity Method
40-50 1125.38 90-270 2.20 Effective Floor Cavity Reflectance 0.20
50-60 1688.89 Diagonal 3.50 % Ceiling Rcc 80 70 50 30 10 0
60-70 3137.76 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 2421.27 Zonal Lumen Summary 0 89 89 89 89 86 86 86 86 79 79 79 73 73 73 68 68 68 65
80-90 1145.98 Zone Lumens % Lamp % Fixture 1 76 70 65 60 72 67 62 58 61 57 54 56 53 50 51 48 46 43
90-100 411.16 0-30 425.77 2.7 3.4 2 66 56 49 42 62 54 47 41 49 43 38 44 39 35 40 36 32 29
100-110 632.32 0-40 889.22 5.6 7.2 3 58 46 38 31 54 44 36 30 40 33 27 36 30 25 32 27 23 21
110-120 448.30 0-60 3703.50 23.1 29.8 4 51 39 30 23 48 37 29 22 33 26 21 30 24 19 27 22 17 15
120-130 293.08 0-90 10408.50 65.1 83.8 5 46 34 25 18 43 32 24 18 29 22 16 26 20 15 23 18 13 11
130-140 154.61 90-120 1491.78 9.3 12.0 6 42 29 21 15 40 28 20 14 25 18 13 22 16 12 20 15 11 8
140-150 59.30 90-130 1784.86 11.2 14.4 7 39 26 18 12 36 25 17 12 22 15 11 20 14 10 18 13 9 7
150-160 9.99 90-150 1998.77 12.5 14.4 8 36 23 15 10 33 22 15 10 20 13 9 18 12 8 16 11 7 5
160-170 0.49 90-180 2009.26 12.6 16.2 9 33 21 14 9 31 20 13 8 18 12 8 16 11 7 15 10 6 4
170-180 0.00 0-180 12417.76 77.6 100.0 10 31 19 12 8 29 18 12 7 17 11 7 15 10 6 13 9 5 4
Mercmaster

III Low Profile


Photometric Data
150-Watt High Pressure Sodium
* Photometric data is based on a fixture with a 150-
watt clear High Pressure Sodium lamp (16,000
lumen). For candlepower values of fixtures with
other HPS lamps, use the following multipliers: for
a 100 W (9,500 lumen) HPS lamp 0.594; for a
70 W (6,400 lumen) HPS lamp 0.40; for a 50 W
(4,000 lumen) HPS lamp 0.25. For candlepower
values of fixture with guard, multiply by 0.95.
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 21
F1-21
F
* Photometric data is based on a fixture with a
100-watt clear Metal Halide lamp (8,500 lumen).
For candlepower values of fixtures with other MH
lamps, use the following multipliers: for a 70 W
(5600 lumen) MH lamp 0.66; for a 50 W (3400
lumen) MH lamp 0.40. For Pulse Start Metal Ha-
lide, use the following: for a 150 W (10,500 lumen)
PSMH lamp 1.24; for a 175 W (17,500 lumen)
PSMH lamp 2.06. For candlepower values of fix-
ture with guard, multiply by 0.95.
Mercmaster

III Low Profile


Photometric Data
100-Watt Metal Halide
Zone Lumens Total Luminaire Efficiency = 85.7%
REPORT NUMBER: ML10HG 0-10 21.19 CIE Type Semi-Direct
10-20 93.55
Plane
Spacing
Criteria
Lamps: 100 W Metal Halide with Globe only*
20-30 201.68
30-40 291.92 0-180 3.20 Coefficients of Utilization Zonal Cavity Method
40-50 523.42 90-270 3.20 Effective Floor Cavity Reflectance 0.20
50-60 637.38 Diagonal 3.08 % Ceiling Rcc 80 70 50 30 10 0
60-70 732.34 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 845.58 Zonal Lumen Summary 0 95 95 95 95 89 89 89 89 78 78 78 68 68 68 58 58 58 54
80-90 874.42 Zone Lumens % Lamp % Fixture 1 81 74 69 64 75 69 64 60 60 56 52 51 48 45 43 40 38 34
90-100 870.80 0-30 316.42 4.1 4.7 2 71 62 54 48 66 57 50 45 49 43 39 41 37 33 34 31 28 24
100-110 809.33 0-40 608.33 7.8 9.1 3 64 52 44 37 59 49 41 35 41 35 30 35 30 26 29 25 21 18
110-120 643.44 0-60 1769.13 22.7 26.5 4 57 45 37 30 53 42 34 28 36 29 24 30 25 20 25 20 17 14
120-130 139.00 0-90 4221.46 54.1 63.2 5 52 40 31 25 48 37 29 23 31 25 20 26 21 17 21 17 14 11
130-140 0.71 90-120 2323.56 29.8 34.8 6 48 35 27 21 44 33 25 19 28 21 17 23 18 14 19 15 11 9
140-150 0.00 90-130 2462.56 31.6 36.8 7 44 31 23 17 40 29 22 16 25 19 14 21 16 12 17 13 10 7
150-160 0.00 90-150 2463.27 31.6 36.8 8 41 28 20 15 37 26 19 14 22 16 12 19 14 10 16 11 8 6
160-170 0.00 90-180 2463.27 31.6 36.8 9 38 26 18 13 35 24 17 12 20 15 11 17 12 9 14 10 7 5
170-180 0.00 0-180 6684.73 85.7 100.0 10 35 23 16 12 32 22 15 11 19 13 9 16 11 8 13 9 6 5
Zone Lumens Total Luminaire Effieciency = 75.8%
REPORT NUMBER: ML10HST 0-10 116.29 CIE Type Direct
10-20 371.61
Plane
Spacing
Criteria
Lamps: 100 W Metal Halide with
Standard Dome Reflector*
20-30 692.88
30-40 821.73 0-180 1.70 Coefficients of Utilization Zonal Cavity Method
40-50 1064.03 90-270 1.70 Effective Floor Cavity Reflectance 0.20
50-60 1154.58 Diagonal 1.84 % Ceiling Rcc 80 70 50 30 10 0
60-70 1134.19 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 470.22 Zonal Lumen Summary 0 90 90 90 90 88 88 88 88 84 84 84 81 81 81 77 77 77 76
80-90 83.66 Zone Lumens % Lamp % Fixture 1 82 78 74 71 80 76 73 70 73 70 68 70 68 66 67 65 64 62
90-100 0.82 0-30 1180.78 15.1 20.0 2 73 66 61 56 71 65 60 55 62 58 54 60 56 53 57 54 51 50
100-110 0.00 0-40 2002.50 25.7 33.9 3 66 57 50 45 64 56 50 45 54 48 44 51 47 43 49 46 42 40
110-120 0.00 0-60 4221.11 54.1 71.4 4 60 50 43 37 58 49 42 37 47 41 36 45 40 36 43 39 35 33
120-130 0.00 0-90 5909.17 75.8 100.0 5 54 44 36 31 53 43 36 31 41 35 30 40 34 30 38 33 30 28
130-140 0.00 90-120 0.82 0.0 0.0 6 50 39 32 26 48 38 31 26 37 31 26 35 30 26 34 29 25 24
140-150 0.00 90-130 0.82 0.0 0.0 7 46 35 28 23 45 34 27 23 33 27 22 32 26 22 31 26 22 20
150-160 0.00 90-150 0.82 0.0 0.0 8 43 32 25 20 41 31 24 20 30 24 20 29 24 20 28 23 19 18
160-170 0.00 90-180 0.82 0.0 0.0 9 40 29 22 18 38 28 22 18 27 22 17 27 21 17 36 21 17 16
170-180 0.00 0-180 5910.00 75.8 100.0 10 37 26 20 16 36 26 20 16 25 20 16 24 19 16 24 19 15 14
Effective August, 2008
Copyright 2008
PAGE 22
800-621-1506
www.appletonelec.com

F1-22
F
* Photometric data is based on a fixture with a
100-watt clear Metal Halide lamp (8,500 lumen).
For candlepower values of fixtures with other MH
lamps, use the following multipliers: for a 70 W
(5600 lumen) MH lamp 0.66; for a 50 W (3400
lumen) MH lamp 0.40. For Pulse Start Metal Ha-
lide, use the following: for a 150 W (10,500 lumen)
PSMH lamp 1.24; for a 175 W (17,500 lumen)
PSMH lamp 2.06. For candlepower values of fix-
ture with guard, multiply by 0.95.
Mercmaster

III Low Profile


Photometric Data
100-Watt Metal Halide
Zone Lumens Total Luminaire Effieciency = 71.3%
REPORT NUMBER: ML10HAN 0-10 91.83 CIE Type Direct
10-20 301.65
Plane
Spacing
Criteria
Lamps: 100 W Metal Halide with
30 Angle Dome Reflector*
20-30 543.23
30-40 703.02 0-180 2.08 Coefficients of Utilization Zonal Cavity Method
40-50 877.11 90-270 2.06 Effective Floor Cavity Reflectance 0.20
50-60 850.33 Diagonal 1.76 % Ceiling Rcc 80 70 50 30 10 0
60-70 7753.51 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 667.27 Zonal Lumen Summary 0 84 84 84 84 82 82 82 82 77 77 77 73 73 73 69 69 69 68
80-90 471.44 Zone Lumens % Lamp % Fixture 1 74 69 65 62 71 67 64 60 63 60 58 60 57 55 57 55 53 51
90-100 200.90 0-30 936.72 12.0 16.8 2 66 59 53 48 64 57 51 47 54 49 45 51 47 43 48 45 42 40
100-110 62.89 0-40 1639.74 21.0 29.5 3 59 51 44 38 57 49 43 38 46 41 36 44 39 35 41 37 34 32
110-120 14.42 0-60 3367.18 43.2 60.6 4 54 44 37 31 52 43 36 31 40 35 30 38 33 29 36 32 28 27
120-130 1.07 0-90 5281.39 67.7 95.0 5 49 39 32 26 47 38 31 26 36 30 25 34 29 25 32 28 24 22
130-140 0.00 90-120 278.21 3.6 5.0 6 45 35 28 23 43 34 27 22 32 26 22 30 25 21 29 24 21 19
140-150 0.00 90-130 279.28 3.6 5.0 7 42 31 24 20 40 30 24 19 29 23 19 27 22 18 26 22 18 16
150-160 0.00 90-150 279.28 3.6 5.0 8 39 28 22 17 37 28 21 17 26 21 17 25 20 16 24 19 16 14
160-170 0.00 90-180 279.28 3.6 5.0 9 36 26 19 15 35 25 19 15 24 19 15 23 18 14 22 17 14 13
170-180 0.00 0-180 5560.68 71.3 100.0 10 34 24 18 14 32 23 17 13 22 17 13 21 16 13 20 16 13 11
Zone Lumens Total Luminaire Effieciency = 76.6%
REPORT NUMBER: ML10HJ5 0-10 9.17 CIE Type Semi-Direct
10-20 75.43
Plane
Spacing
Criteria
Lamps: 100 W Metal Halide with
8 Prismatic Glass Refracter NEMA Type V*
20-30 154.76
30-40 266.34 0-180 2.06 Coefficients of Utilization Zonal Cavity Method
40-50 632.54 90-270 2.20 Effective Floor Cavity Reflectance 0.20
50-60 1155.59 Diagonal 3.26 % Ceiling Rcc 80 70 50 30 10 0
60-70 1665.76 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 693.73 Zonal Lumen Summary 0 89 89 89 89 85 85 85 85 79 79 79 73 73 73 68 68 68 65
80-90 449.28 Zone Lumens % Lamp % Fixture 1 77 71 67 62 73 68 64 60 63 59 56 58 55 52 53 51 49 46
90-100 177.44 0-30 239.35 3.1 4.0 2 67 58 51 45 64 56 49 44 51 46 41 47 42 38 43 39 36 33
100-110 288.25 0-40 505.69 6.5 8.5 3 59 48 40 34 56 46 39 32 42 36 30 38 33 28 34 30 26 24
110-120 208.52 0-60 2293.81 29.4 38.4 4 52 41 32 26 49 39 31 25 35 28 23 32 26 21 29 24 20 18
120-130 128.19 0-90 5102.58 65.4 85.4 5 47 35 26 20 44 33 25 19 30 23 18 27 21 17 25 20 15 13
130-140 56.80 90-120 674.20 8.6 11.3 6 43 30 22 16 40 29 21 15 26 19 14 24 18 13 21 16 12 10
140-150 14.94 90-130 802.38 10.3 13.4 7 39 27 19 13 37 25 18 13 23 16 12 21 15 11 19 14 10 8
150-160 0.10 90-150 874.12 11.2 13.4 8 36 24 16 11 34 23 15 10 21 14 10 19 13 9 17 12 8 6
160-170 0.00 90-180 874.22 11.2 14.6 9 33 21 14 9 31 20 14 9 19 12 8 17 11 8 15 10 7 5
170-180 0.00 0-180 5976.80 76.6 100.0 10 31 19 12 8 29 19 12 8 17 11 7 15 10 6 14 9 6 4
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 23
F1-23
F
Mercmaster

III HID 50-250 W


Enclosed and Gasketed Fixtures for Hazardous and Adverse Locations
High Pressure Sodium, Metal Halide and Pulse Start Metal Halide.
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Applications
Enclosed and gasketed fixtures
suitable for use in marine and wet
locations and in a wide range of
industrial, chemical processing and
other areas where flammable gases
and vapors or combustible dusts are
present under conditions defined by
NEC Class I, Div. 2; Class II, Div. 1
and 2; and Class III. The method of
protection for the Zone 2 Mercmaster
is Restricted Breathing and Restricted
Breathing/Nonsparking.
Suitability includes listing for use
where there may be simultaneous
exposure to combustible dusts and
flammable gases and vapors. See list-
ing pages for compliance data on spe-
cific fixture component combinations.
Fixtures are also well suited for
use in non-hazardous areas where
severe weather conditions, excessive
moisture, dirt, dust, corrosive atmo-
spheres or high ambient tempera-
tures are encountered. 18% cooler
operation allows use in ambient tem-
peratures up to 65 C depending on
fixture component combinations.
Typical applications include pulp and
paper mills, processing plants, chem-
ical plants, oil refineries, foundries,
manufacturing plants, storage areas
and marine applications. Fixtures
have NEMA 4X listing.
Features
Modular design allows scores of
fixture component combinations to
meet installation and lighting needs.
Many most-used combinations are
offered prewired and assembled,
complete with lamp, packaged in a
single carton and ready to install.
Mogul lamp types and wattages:
HPS 50W-150W
MH 100W-250W
PSMH 175W-200W
Choice of heat-resistant prismatic
glass refractors (NEMA distributions I,
III and V), or heat-resistant prismatic
glass globes for hazardous area fix-
tures. Colored and clear polycarbonate
globes and Tuff-skin coated glass
globes are available but are NOT
approved for use in classified areas.
Tuff-skin

is a registered trademark of Thomas Manufacturing Corp., Parkton, Maryland.


Pendant Mount
Fixture with
Prismatic Glass
Refractor
Pendant Fixture
with Cone Hood and
Prismatic Glass
Globe and Guard
Straight Stanchion-Mount
Fixture with Prismatic
Glass Refractor
and Guard
Ceiling Mount Fixture
with Prismatic Glass
Globe, Guard and
Polyester 30 Angle
Reflector
Fixtures with these globes do NOT
comply with code requirements, and
should be used in non-classified areas
only. Globes and refractors thread
directly into ballast housing.
Mounting hoods include cone-
shaped pendant hood, standard
pendant, flexible pendant, ceiling
and wall pendants (tapped for 3/4
or 1 NPT), 25angle stanchion,
and 90(straight) stanchion (both
tapped for 1-1/4 or 1-1/2 NPT).
Cone hood fixtures for pendant
mounting shed dust, dirt and
combustible fibers. Cone hood
inhibits build-up that insulates
fixture and slows heat transfer, and
provides increased surface area for
more effective heat dissipation.
Effective August, 2008
Copyright 2008
PAGE 24
800-621-1506
www.appletonelec.com

F1-24
F
Reflector choice includes standard
dome and 30 angle types, both
made of fiberglass-reinforced white
polyester. Highly resistant to unusu-
ally corrosive applications. Reflectors
are vented for cooler, dirt-free opera-
tion and maintained lumen output.
They secure to ballast housing with
stainless steel screws threading into
stainless steel inserts.
For high corrosion resistance, fix-
ture housing, mounting hoods and
guards are copper-free cast alumi-
num with baked epoxy finish, elec-
trostatically applied for uniformity. All
exposed hardware is stainless steel.
Hinge has high lip for added safety
during installation and servicing.
Hinge and bolt construction assures
360 compression at all points on
ballast housing gasket for positive
sealing. Swing-away design of cap-
tive bolt and nut simplifies servicing.
Body gaskets and globe gaskets are
high-temperature silicone rubber.
Capacitors are non-PCB type, ther-
mally isolated from ballast.
Mogul base porcelain socket with
nickel-plated contacts has 200 C
welded leads, prewired to the bal-
last. Assures trouble-free operation
in installations where high ambient
temperatures are encountered.
HPS ballasts are High Power Factor
(min. P.F. 90%). 50 W HPS fixtures
have dual-tap (120 V or 277 V) bal-
last. All other fixtures have multi-tap
ballast (120 V, 208 V, 240 V or
277 V) or 480 V ballast. Ballasts are
Class H insulated.
All Mercmaster III mounting hoods
have provision for easy field installa-
tion of fuses in fixtures (see fuse kit
listings in this catalog section).
For electrical protection, a ground
wire is provided on each Mercmaster
to bond hood and ballast housing.
The AEx nA nR Mercmaster III fix-
ture is factory sealed and prevents
vapors and gases from entering the
globe chamber. There are no seals
or putty required.
The AEx nR Mercmaster III fixture
requires all wiring entries to be
sealed.
Standard Materials
Mounting hoods, ballast bodies and
guards: copper-free cast aluminum
(less than 4/10 of 1%).
Exposed hardware: stainless steel;
latch assemblies have stainless
steel bolt and captive nut; reflectors
and guards attach with strainless
steel screws threading into stainless
steel inserts.
Reflectors: fiberglass-reinforced
white polyester.
Globes: heat-resistant prismatic glass.
Refractors: heat-resistant prismatic
glass.
Standard Finishes
Mounting hoods, ballast bodies,
guards: epoxy powder coat finish,
electrostatically applied for com-
plete, uniform surface protection.
Reflectors: white polyester finish.
Options
AEx nA nR fixtures are available with
a Class I, Zone 2 rating. Add suffix
-Z2.
AEx nR fixtures are available with
a Class I, Zone 2 rating. Add suffix
-ZB.
Fuses can be field-installed on
Mercmaster III fixtures. Kits include
fuse block, wire connectors and
screws for attaching to mounting
hood. Fixtures with fuses do not
comply with Marine Type Electric
Fixtures Outside Type (Salt Water)
requirements for marine listing. See
page F1-39 for fuse kits.
Hot Restrike will restrike HPS lamp
immediately when power is restored
after a momentary power interrup-
tion. Add suffix -R.
Smart Hot Restrike will immediately
restrike HPS lamp when power is
restored after a momentary power
interruption. The smart function
removes the hot restrike ignitor
from the circuit if the lamp burns
out or is removed from the socket.
Eliminates starter failures caused by
prolonged operation with cycling or
failing lamps. Add suffix -SR.
Smart Starter (for HPS fixtures
only) incorporates a 1-1/2-minute
timer and performs as a conven-
tional starter to normally start lamp.
Removes itself from circuit if lamp
burns out or is removed from sock-
et. Eliminates starter failures caused
by prolonged operation with cycling
or failing lamps and simplifies find-
ing their location, reducing mainte-
nance and repair costs. Available for
all HPS fixtures. Add suffix -S.
Optional photocell for all fixtures
except cone and ceiling mount pro-
vides automatic on-off control.
Quartz Auxiliary comes to full
brightness immediately and remains
lit until the HID lamp attains 60-70%
of full illumination. Quartz Auxiliary
supplied with relay switch and sock-
et to accept 120 V quartz double
contact bayonet base lamp (not
included). Add suffix -E to fixture
catalog number.
Classified area photo controls are
also available (see page F1-12
and F1-136).
Compliances*
UL Listed for Simultaneous Expo-
sure Class I, Div. 2 and Class II,
Div. 1 and 2
UL Standards 1598A, Marine Type
Electric Fixtures Outside Type (Salt
Water) and 844
UL 2279
NEMA 4X; IP66
Class I, Div. 2, Groups A,B,C,D
Class I, Zone 2 AEx nA nR IIC
Class I, Zone 2 AEx nR IIC
Class II, Div. 1 and 2, Groups E,F,G
Class III
* Compliance data varies for specific fixtures.
Consult Appleton regarding suitability of
specific fixtures for a particular application.
Fixtures equipped with a quartz auxiliary lamp do not comply with UL requirements and are not suitable for use in classified locations.
Mercmaster

III HID 50-250 W


Enclosed and Gasketed Fixtures for Hazardous and Adverse Locations
High Pressure Sodium, Metal Halide and Pulse Start Metal Halide.
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 25
F1-25
F
Mercmaster

III HID 50-250 W


Enclosed and Gasketed Fixtures for Hazardous and Adverse Locations
High Pressure Sodium, Metal Halide and Pulse Start Metal Halide.
CATALOG NUMBERING GUIDE FOR MERCMASTER III 250 LUMINAIRES
KP A L 70 10 J5 G MT F Z2
SERIES:
KP - Mercmaster III-250
GUARD OPTION:
Blank - No Guard
G - Guard
MOUNTING:
A - Pendant (Rigid Mounting)
C - Ceiling
F - Pendant (Flexible Mounting)
CH - Pendant Cone
ST - 90 Stanchion
S - 25 Stanchion
WB - Wall
OPTIC OPTIONS:
Blank - Glass Globe
J1 - NEMA I glass refractor
J3 - NEMA III glass refractor
J5 - NEMA V glass refractor
G3 - Large glass globe
WATTAGE:
50 - 50 W HPS
70 - 70 W HPS
10 - 100 W HPS, MH
15 - 150 W HPS
17 - 175 W MH, PSMH
20 - 200 W PSMH
25 - 250 W MH
LAMP TYPE:
H - Metal Halide
L - High Pressure
Sodium
P - Pulse Start
Metal Halide
OPTIONS:
F - Fuse (specify voltage)
R - Hot Restrike
(50-150 W HPS Only)
S - Smart Starter
(50-150 W HPS Only)
K - Kynar Coating
E - Emergency Quartz
SUFFIX:
Z2 - Zone 2 suffix for
Non-Sparking/
Restricted Breathing
(AEx nA nR rating)
ZB - Zone 2 suffix for
Restricted Breathing
(AEx nR rating)
HUB SIZE:
75 - 3/4" NPT
10 - 1" NPT
125 - 1-1/4" NPT
stanchion
150 - 1-1/2" NPT
stanchion
Ordering Information:
Order using catalog numbering guide below or select catalog number from tables on following pages.
* Voltages shown are limited to specific combinations; refer to page F1-39.
Reflectors are ordered separately see accessories page.
VOLTAGE*:
MT - 120/208/240/277 V, 60 Hz
5MT - 120/208/240/277/480 V, 60 Hz
FM - 127/220 V, 60 Hz
AM - 127/220 V, 60 Hz
FA - 220 V, 60 Hz
48 - 480 V, 60 Hz
GP - 120/220/240 V, 50 Hz
XQ - 120/230 V, 50 Hz
GK - 220/240 V, 50 Hz
Effective August, 2008
Copyright 2008
PAGE 26
800-621-1506
www.appletonelec.com

F1-26
F
Mercmaster

III HID 50-250 W


Emergency Lighting Accessories
Quartz Emergency Light for Metal Halide or High Pressure Sodium Fixtures*
Mercmaster fixtures for or metal halide and high pressure sodium lamps can be
supplied with a socket to accept a 150 W or 250 W, 120 V quartz lamp. This D.C.
bayonet base socket is in addition to the standard lamp socket. In the event of a
momentary power interruption, the quartz lamp is automatically switched on. The
single ended quartz lamp remains energized until the HID restrikes and reaches
about 60% output.
The quartz emergency lamp socket is wired to a 120 V tap on the ballast and
is therefore independent of the lighting fixture voltage. No special field wiring is
necessary.
Catalog
Description Suffix
For fixture volts of 120, 208, 240 or 277 . . . . . . . . . . . . . . . . . . . . . . . -MTE
For fixture volts of 480 . . . . . . . . . . . . . . . . . -48E (MMIII) or -480E (MMII)
(250 W metal halide fixture suitable for a maximum of 150 W quartz only)
*NOTE: Fixtures equipped with quartz emergency light do not comply with UL requirements and are
not suitable for use in classified locations.
HPS Smart Hot Restrike Accessory for HPS Fixtures
Mercmaster fixtures for high pressure sodium lamps can be supplied with a special
ignitor (starter board). It instantly restrikes a hot high pressure sodium lamp when
a momentary power interruption occurs. This special ignitor, supplied in place of
the standard ignitor, is a potted solid state device, totally factory installed. It is not
suitable for field installation.
The hot lamp restart option provides instant restart of 50, 70, 100 and 150 W
HPS lamps after power outages of up to 10 seconds. The lamps restrike instantly
at almost full lumens. For power interruptions of up to 30 seconds, the restart of
the high pressure sodium lamp is also instant but at less than full lumens. The hot
lamp restart accessory does not accelerate cold lamp start up or starting where
the power outage is of a duration which has allowed the HPS lamp to cool.
Additional Advantages of the Smart Hot Restrike:

Protects against self destruction in the event of failed, missing or broken lamps,
or socket or lead wire failure.

Prevents End of Life lamps from continuous cycling over long periods of time.

Remains unaffected by stray voltages, moderate overvoltages, as well as under-
voltage conditions.

Drops into the background during normal lamp operation with exceptionally low
insertion loss.

Fully encapsulated construction assures electrical integrity and mechanical vibra-
tion protection.

U.L. recognized component.
Catalog
Description Suffix
For fixture watts of 50, 70, 100 or 150 (HPS only) . . . . . . . . . . . . . . . . -SR
Encapsulated HPS
Smart Hot Restrike
Ignition Accessory
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 27
F1-27
F
Mercmaster

III HID 50-250 W


Illustrated Features: Enclosed and Gasketed Fixtures for
Hazardous and Adverse Locations
High Temperature Socket
Mogul base high-temperature porcelain
socket for 50W thru 250W HID lamps.
Aluminum Inner Reflector
Solid aluminum inner reflector improves
photometric efficiency.
Stainless Steel
Latch Assembly
Captive, stainless
steel latch assembly
bolt and nut closes
securely, resists
attack of corro-
sive atmospheres.
Swing-away design
simplifies servicing.
Rugged, Vented Reflectors
Reflectors are thick, tough fiberglass-
reinforced white polyester, vented for
cooler operation. Quickly attach with
stainless steel screws provided.
Photocell
Available for all fixtures except cone and
ceiling mount. Installs through knock-out
in mounting hood. Provides continuous
ON-OFF dusk-to-dawn control.
Electrical Protection
Ground wire provided to bond mounting
hood to ballast housing.
Cone Hood for Cooler Operation
Sloped surface sheds insulating dust,
dirt and combustible fibers. Provides
cleaner, larger surface area for better
heat dissipation.
Threaded Stainless Steel Inserts for Screws
Ballast bodies have stainless steel
threaded inserts to receive stainless
steel screws for reflector and guard.
Prevents freezing, allowing guards
and reflectors to be easily removed and
replaced at any time, without damage to
the housing.
Epoxy Finish
Gasketed ballast housing, hoods and
guards are cooper-free aluminum with
epoxy powder coat finish.
Ballast Assembly (Zone 2)
Utilizing non-sparking components
avoiding the ignition of gases or vapors
that may be present (nA).
Hood/Ballast Gasket
Silicone rubber gasket seals out mois-
ture, dirt and dust. Stays flexible, with-
stands high temperatures. Closure design
assures uniform gasket compression.
Safety
High Hinge
Provides extra protec-
tion against accidental
ballast housing disen-
gagement during instal-
lation or maintenance.
Heat-Resistant Globes and Refractors
Prismatic glass globes and refractors are
heat-resistant. They thread directly into
the ballast housing and seal against a
high-temperature silicone rubber gasket.
Fuses Mount to Hood Bosses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Globe Chamber (Zone 2)
Completely sealed from the ballast
housing and outside vapors/air (nR).
Terminal Blocks (Zone 2)
A seven-point terminal block is provided
to facilitate wiring. Terminal block accom-
modates wire size ranging from #8 to
#24 AWG.
Effective August, 2008
Copyright 2008
PAGE 28
800-621-1506
www.appletonelec.com

F1-28
F
Mercmaster

III HID 50-250 W


Thermal Performance: Class I, Div. 2; Class II, Div. 1; and
Simultaeous Exposure to hazardous conditions of both classifications
Temperature Identification Numbers of Mercmaster III fixtures
In compliance with the 1999 National
Electrical Code, Mercmaster III fixtures
are listed for Simultaneous Exposure
to combinations of Class I, Div. 2 and
Class II, Div. 1 hazardous conditions.
The larger housing results in cooler
operation and provides an expanded
range of T numbers as indicated in
the following table.
T Numbers Represent the Maximum Lamp Temperature for Class I, Div. 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Div. 1 Locations.
T Numbers for Mercmaster III Fixtures
Lamp
Supply
Wire
Temp.
(C)
Ambient
Temp.
(C)
Class I, Div. 2
Class II, Div. 1
Groups E, F and G
Simultaneous Exposure
Class I, Div.2 / Class II, Div. 1
Watts Type Globe
Globe &
Reflector
G3
Globe
8
Refractor Globe
Globe &
Reflector
G3
Globe
8
Refractor Globe
Globe &
Reflector
G3
Globe
8
Refractor
60 40 T3C T3B T3C T4A T4 T6 T3A T3 T3C
50 HPS 75 55 T3A T3A T3A T4 T3B T5 T3 T3 T3A
75 65 T3A T3 T3A T3C T3C T4A T2D T2D T3
75 40 T3B T3A T3C T4 T3C T6 T3 T3 T3A
70 HPS 90 55 T3A T3A T3B T3C T3C T5 T2D T2D T3
90 65 T3 T3A T3A T3C T3B T4A T2C T2C T3
90 40 T2D T2D T3 T3 T3A* T3*
100 HPS 90 40 T3B T4A T4A T2B T2B T2C T2C
90 55 T2D T2D T3 T3 T4 T4 T2B T2B
90 65 T2D T2D T2D T2D
90 40 T2B T2B T2C T3C T2 T2B
150 HPS 90 40 T3*
90 55 T2B T2A T2B
90 40 T3 T3 T3 T3C T2B
100 MH 90 55 T3 T3 T3 T3C T2A
90 65 T2D T2D T2D T3C
90 40 T2B T2B T2B T3C T2B
175 MH 90 55 T2A T2A T2B T3C T2A
110 65 T2A T2 T2B
250 MH 90 40 325 325 T2 T3B 325
90 40 T2B T2B T2B T3C T2B
175 PSMH 90 55 T2A T2A T2B T3C T2A
90 65 T2A T2 T2B
200 PSMH 90 40 T2B 325 T2 T3B 325
90 55 T2B
T Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
Range
(C)
351-450 326-350 301-325 281-300 261-280 231-260 216-230 201-215 181-200 166-180 161-165 136-160 121-135 101-120 86-100 85
* T numbers are for Groups E and F only.
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 29
F1-29
F
Mercmaster

III HID 50-250 W


Thermal Performance: Class I, Zone 2, AEx nA nR IIC;
Class 1 Zone 2, AEx nR IIC; IP66; and NEMA 4X
Temperature Identification Numbers of Mercmaster III Fixtures
Operating Temperatures: T Numbers for Zone 2 Mercmaster III Fixtures
Lamp Supply
Wire
Temp.
C
Ambient
Temp.
C
Class I, Zone 2 AEx nA nR IIC Class I, Zone 2 AEx nR IIC
Watts Type Globe
Globe &
Reflector
G3/Refractor Globe
Globe &
Reflector
G3/Refractor
50 HPS
75 40 T4 T4 T6 T4 T4 T6
90 55 T4 T3 T5 T4 T3 T5
90 65 T3 T3 T4 T3 T3 T4
70 HPS
75 40 T4 T4 T4 T6 T5 T6
90 55 T4 T4 T4 T5 T4 T5
90 65 T4 T4 T3 T4 T4 T5
100 HPS
90 40 T4 T4 T4 T5 T4 T6
90 55 T4 T4 T3 T4 T4 T5
90 65 T4 T4 T3 T4 T4 T4
150 HPS
90 40 T3 T3 T3 T4 T4 T5
90 55 T3 T3 T3 T4 T4 T4
105 65 T3 T3 T3 T4 T3 T4
100 MH
90 40 T4 T4 T3 T5 T4 T6
90 55 T4 T4 T3 T4 T4 T5
90 65 T3 T3 T3 T4 T3 T4
175 MH
90 40 T3 T3 T4 T3 T3 T4
125 55 T3 T3 T3 T3 T3 T4
125 65 T3 T3 T3 T3 T3 T4
250 MH 90 40 T3 T3 T3 T3 T3 T3
175 PSMH
90 40 T3 T3 T3 T3 T3 T4
90 55 T3 T3 T3 T3 T3 T4
105 65 T3 T3 T3 T3 T3 T4
200 PSMH
90 40 T3 T3 T3 T3 T3 T4
105 55 T3 T3 T3 T3 T3 T4
105 65 T3 T3 T3 T3 T3 T4
* For use with catalog number KR2-ST and KR2-AN reectors
The T number is established by separately determining the maximum temperature of the globe surface and ballast compartment.
The hotter of the two is taken to determine the T number for the overall xture.
T Numbers Represent the Maximum Surface Temperature for Luminaries with AEx nA nR or AEx nR only rating
T Number T1 T2 T3 T4 T5 T6
Temp. Range (C) 301-450 201-300 136-200 101-135 86-100 85
Effective August, 2008
Copyright 2008
PAGE 30
800-621-1506
www.appletonelec.com

F1-30
F
Mercmaster

III HID 50-250 W


Classified Area Suitability: Class I, Div. 2; Class II, Div. 1; and
Simultaeous Exposure to hazardous conditions of both classifications
Maximum Temperatures in C Obtained from Tests in a 40 C Ambient,
Vertical Position, Lamp Base Up, as per NEC.
Fixture Selection Guide* Indicates atmosphere for which fixture is suitable
Denotes fixture with Globe Only. Denotes fixture with Globe and Reflector. Denotes fixture with 8 Refractor / G3 Globe
Group D atmospheres continued to next page.
Not Available. See next page for additional notes
Class I, Div. 2 Chemical
Ignition
C
Min. Fixt.
T No. for
Chemical
HPS (Watts) MH (Watts) PSMH (Watts)
50 70 100 150 100 175 250 175 200
Group A Atmospheres
acetylene 305 T2
Group B Atmospheres
acrolein (inhibited) 220 T2D
arsine NA
butadiene 420 350
ethylene oxide 429 350
hydrogen 500 T1
propylene oxide 449 350
propylnitrate 175 T3B
Group C Atmospheres
acetaldehyde 175 T3B
allyl alcohol 378 350
n-butyraldehyde 218 T2D
carbon monoxide 609 T1
crotonaldehyde 232 T2C
cyclopropane 498 T1
diethyl ether (ethyl ether) 160 T3C
diethylamine 312 T2
ethylene 450 T1
ethylenimine 320 T2
ethly mercaptan 300 T2
ethyl sulde NA
hydrogen cyanide 538 T1
hydrogen sulde 260 T2B
morpholine 310 T2
2-nitropropane 428 350
tetrahydrofuran 321 T2
unsymmetrical dimethyl hydrazine 249 T2C
Group D Atmospheres
acetic acid (glacial) 464 T1
acetone 465 T1
acrylonitrile 481 T1
ammonia 651 T1
benzene 498 T1
butane 287 T2A
1-butanol (butyl alcohol) 343 325
2-butanol (secondary butyl alcohol) 405 350
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 31
F1-31
F
Fixture Selection Guide* Indicates atmosphere for which fixture is suitable
Denotes fixture with Globe Only. Denotes fixture with Globe and Reflector. Denotes fixture with 8 Refractor / G3 Globe
Continued from preceding page
* Where no fixture is indicated suitable for the specific chemical, see catalog section G1.
A saturated hydrocarbon mixture. Also known by synonyms benzine, ligroin, petroleum, ether and naptha.
Ignition temperatures shown should be regarded as approximations only. Per NFPA Bulletin 325M, ignition temperatures may vary according to such factors as
vapor/air mixture, size and space where ignition may occur, rate and duration of heating, oxygen concentration and other materials present.
This classified area suitability chart is based on NEC requirements and Appleton and UL testing. However, the ultimate decision on suitability of these fixtures for
classified areas depends solely on the judgement of the owner, insurance company, inspector and/or authority having jurisdiction.
Class I, Div. 2 Chemical
Ignition
C
Min. Fixt.
T No. for
Chemical
HPS (Watts) MH (Watts) PSMH (Watts)
50 70 100 150 100 175 250 175 200
Group D Atmospheres
n-butyl acetate 425 350
isobutyl acetate 421 350
sec-butyl alcohol 343 325
di-isobutylene 391 350
ethane 472 T1
ethanol (ethyl alcohol) 363 350
ethyl acetate 426 350
ethylene diamine (anhydrous) 385 350
ethylene dichloride 413 350
gasoline (56-60 octane) 280 T2A
heptanes 204 T3
hexanes 223 T2D
isoprene 395 350
isopropyl ether 443 350
mesityl oxide 344 325
methane (natural gas) 537 T1
methanol (methyl alcohol) 385 350
3-methyl-l-butanol (isoamyl alcohol) 350 350
methyl ethyl ketone 404 350
methyl isobutyl ketone 448 350
2-methyl-1-propanol (isobutyl alcohol) 415 350
2-methyl-1-propanol (tertiary butyl alcohol) 478 T1
petroleum naphtha 288 T2A
pyridine 482 T1
octanes 206 T3
pentanes 260 T2B
1-pentanol (amyl alcohol) 300 T2
propane 432 350
1-propanol (propyl alcohol) 412 350
2-propanol (isopropyl alcohol) 399 350
propylene 455 T1
styrene 490 T1
toluene 480 T1
vinyl acetate 402 350
vinyl chloride 472 T1
xylenes (o-xylene) 463 T1
Mercmaster

III HID 50-250 W


Classified Area Suitability: Class I, Div. 2; Class II, Div. 1; and
Simultaeous Exposure to hazardous conditions of both classifications
Maximum Temperatures in C Obtained from Tests in a 40 C Ambient,
Vertical Position, Lamp Base Up, as per NEC.
Effective August, 2008
Copyright 2008
PAGE 32
800-621-1506
www.appletonelec.com

F1-32
F
Mercmaster

III HID 50-250 W


Classified Area Suitability: Class I, Zone 2, AEx nA nR IIC;
Class 1 Zone 2, AEx nR IIC; IP66; and NEMA 4X
Maximum Temperatures in C Obtained from Tests in a 40C Ambient,
Vertical Position, Lamp Base Up.
Fixture Selection Guide* Indicates atmosphere for which fixture is suitable
Denotes fixture with Globe and Reflector. Denotes fixture with 8 Refractor.
Chemical
Ignition
C
Min. Fixt
T No. for
Chemical
HPS (Watts) MH (Watts) PSMH (Watts)
50 70 100 150 100 175 250 175 200
Group IIC
acetylene 305 T2
acetylene 300 T2
hydrogen 500 T1
Group IIB
ethylene 490 T1
butadiene 1.3 425 T2
carbon monoxide coke oven gas 560 T1
diethyl ether (ethyl ether) 160 T4
ethylene 450 T1
ethylenimine ethylene oxide 425 T2
Group IIA
acetone 465 T1
amyl acetate 375 T2
ammonia 651 T1
benzene 498 T1
butane 287 T3
1-butanol (butyl alcohol) 343 T2
n-butyl acetate cyclohexane 260 T3
ethyl methyl ketone 515 T1
ethanol (ethyl alcohol) 363 T2
ethyl acetate 426 T1
heptanes 204 T3
hexanes 223 T3
isoprene isobutanol 430 T2
mesityl oxide methyl acetate 500 T1
methanol (methyl alcohol) 385 T2
n-propyl acetate 500 T1
n-butul acetate 420 T2
pentanes 260 T3
propane 432 T2
xylenes (o-xylene) 463 T1
* Where no fixture is indicated suitable for the specific chemical, see catalog section G1.
A saturated hydrocarbon mixture. Also known by synonyms benzine, ligroin, petroleum, ether and naptha.
Ignition temperatures shown should be regarded as approximations only. Per NFPA Bulletin 325M, ignition temperatures may vary according to such factors as
vapor/air mixture, size and space where ignition may occur, rate and duration of heating, oxygen concentration and other materials present.
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 33
F1-33
F
Hub
Size
(Inches)
Catalog Numbers 345
Type
Mounting
Lamp
Type
Lamp
Watts
with
Globe
with Type V 8 Refractor
or G3 Globe 2
Pendant HPS 50 3/4 KPAL5075 KPAL5075J5
One Hub,
Rigid Mounting1
1 KPAL5010 KPAL5010J5
HPS 70 3/4 KPAL7075 KPAL7075J5
1 KPAL7010 KPAL7010J5
HPS 100 3/4 KPAL1075 KPAL1075J5
1 KPAL1010 KPAL1010J5
HPS 150 3/4 KPAL1575 KPAL1575J5
1 KPAL1510 KPAL1510J5
Ceiling HPS 50 3/4 KPCL5075 KPCL5075J5
Five Hubs,
Four Close-Up Plugs
1 KPCL5010 KPCL5010J5
HPS 70 3/4 KPCL7075 KPCL7075J5
1 KPCL7010 KPCL7010J5
HPS 100 3/4 KPCL1075 KPCL1075J5
1 KPCL1010 KPCL1010J5
HPS 150 3/4 KPCL1575 KPCL1575J5
1 KPCL1510 KPCL1510J5
Wall HPS 50 3/4 KPWBL5075 KPWBL5075J5
Five Hubs,
Four Close-Up Plugs
1 KPWBL5010 KPWBL5010J5
HPS 70 3/4 KPWBL7075 KPWBL7075J5
1 KPWBL7010 KPWBL7010J5
HPS 100 3/4 KPWBL1075 KPWBL1075J5
1 KPWBL1010 KPWBL1010J5
HPS 150 3/4 KPWBL1575 KPWBL1575J5
1 KPWBL1510 KPWBL1510J5
Mercmaster

III HID 50-250 W


Enclosed and Gasketed Fixtures for Hazardous and Adverse Locations
High Pressure Sodium 50 W, 70 W, 100 W and 150 W
High Reactance, High Power Factor (min. P.F. 90%).
Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps.
UL Listed.
Simultaneous Exposure
Class I, Div. 2/Class II, Div. 1
(See Page F1-28 to F1-30 for group designations)
Class I, Div. 2; Groups A,B,C,D
Class I, Zone 2, AEx nA nR IIC
Class I, Zone 2, AEx nR IIC
Class II, Div. 1 and 2; Groups E,F,G
Class III
UL 1598A, UL 844, Marine Type Electric
Fixtures Outside Type (Salt Water)
UL 2279
NEMA 4X; IP66
1 For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
2 To order xtures with large globe change J5 to G3. To order NEMA Type I or Type III refractor, change J5 to J1 or J3 respectively.
3 Add the following voltage and frequency designations before Z2 or ZB sufx:
Sufx Voltage Frequency Notes
MT 120/208/240/277 60 Hz All
FM 127/220 60 Hz 50 W HPS
FA 220 60 Hz 70 W, 100 W, 150 W HPS
48 480 60 Hz All except 50 W HPS
GP 120/220/240 50 Hz 70 W, 100 W, 150 W HPS
GK 220/240 50 Hz 50 W HPS
4 Add Z2 sufx for factory-sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB sufx for restricted breathing protection (AEx nR).
5 For xtures with guards, substitute G before adding voltage designation.
Effective August, 2008
Copyright 2008
PAGE 34
800-621-1506
www.appletonelec.com

F1-34
F
Hub
Size
(Inches)
Catalog Numbers 345
Type
Mounting
Lamp
Type
Lamp
Watts with Globe
with Type V 8 Refractor
or G3 Globe 2
25 Stanchion HPS 50 1-1/4 KPSL50125 KPSL50125J5
One Hub 1-1/2 KPSL50150 KPSL50150J5
HPS 70 1-1/4 KPSL70125 KPSL70125J5
1-1/2 KPSL70150 KPSL70150J5
HPS 100 1-1/4 KPSL10125 KPSL10125J5
1-1/2 KPSL10150 KPSL10150J5
HPS 150 1-1/4 KPSL15125 KPSL15125J5
1-1/2 KPSL15150 KPSL15150J5
90 Stanchion HPS 50 1-1/4 KPSTL50125 KPSTL50125J5
One Hub 1-1/2 KPSTL50150 KPSTL50150J5
HPS 70 1-1/4 KPSTL70125 KPSTL70125J5
1-1/2 KPSTL70150 KPSTL70150J5
HPS 100 1-1/4 KPSTL10125 KPSTL10125J5
1-1/2 KPSTL10150 KPSTL10150J5
HPS 150 1-1/4 KPSTL15125 KPSTL15125J5
1-1/2 KPSTL15150 KPSTL15150J5
Pendant Cone HPS 50 3/4 KPCHL5075 KPCHL5075J5
One Hub,
Rigid Mounting
1 KPCHL5010 KPCHL5010J5
HPS 70 3/4 KPCHL7075 KPCHL7075J5
1 KPCHL7010 KPCHL7010J5
HPS 100 3/4 KPCHL1075 KPCHL1075J5
1 KPCHL1010 KPCHL1010J5
HPS 150 3/4 KPCHL1575 KPCHL1575J5
1 KPCHL1510 KPCHL1510J5
Mercmaster

III HID 50-250 W


Enclosed and Gasketed Fixtures for Hazardous and Adverse Locations
High Pressure Sodium 100 W, 175 W and 250 W
High Reactance, High Power Factor (min. P.F. 90%).
Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps.
UL Listed.
Simultaneous Exposure
Class I, Div. 2/Class II, Div. 1
(See Page F1-28 to F1-30 for group designations)
Class I, Div. 2; Groups A,B,C,D
Class I, Zone 2, AEx nA nR IIC
Class I, Zone 2, AEx nR IIC
Class II, Div. 1 and 2; Groups E,F,G
Class III
UL 1598A, UL 844, Marine Type Electric
Fixtures Outside Type (Salt Water)
UL 2279
NEMA 4X; IP66
1 For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
2 To order xtures with large globe change J5 to G3. To order NEMA Type I or Type III refractor, change J5 to J1 or J3 respectively.
3 Add the following voltage and frequency designations before Z2 or ZB sufx:
Sufx Voltage Frequency Notes
MT 120/208/240/277 60 Hz All
FM 127/220 60 Hz 50 W HPS
FA 220 60 Hz 70 W, 100 W, 150 W HPS
48 480 60 Hz All except 50 W HPS
GP 120/220/240 50 Hz 70 W, 100 W, 150 W HPS
GK 220/240 50 Hz 50 W HPS
4 Add Z2 sufx for factory-sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB sufx for restricted breathing protection (AEx nR).
5 For xtures with guards, substitute G before adding voltage designation.
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 35
F1-35
F
Hub
Size
(Inches)
Catalog Numbers 345
Type
Mounting
Lamp
Type
Lamp
Watts with Globe
with Type V 8 Refractor
or G3 Globe 2
Pendant MH 100 3/4 KPAH1075 KPAH1075J5
One Hub,
Rigid Mounting1
1 KPAH1010 KPAH1010J5
MH 175 3/4 KPAH1775 KPAH1775J5
1 KPAH1710 KPAH1710J5
MH 2506 3/4 KPAH2575 KPAH2575J5
1 KPAH2510 KPAH2510J5
Ceiling MH 100 3/4 KPCH1075 KPCH1075J5
Five Hubs,
Four Close-Up Plugs
1 KPCH1010 KPCH1010J5
MH 175 3/4 KPCH1775 KPCH1775J5
1 KPCH1710 KPCH1710J5
MH 2506 3/4 KPCH2575 KPCH2575J5
1 KPCH2510 KPCH2510J5
Wall MH 100 3/4 KPWBH1075 KPWBH1075J5
Five Hubs,
Four Close-Up Plugs
1 KPWBH1010 KPWBH1010J5
MH 175 3/4 KPWBH1775 KPWBH1775J5
1 KPWBH1710 KPWBH1710J5
MH 2506 3/4 KPWBH2575 KPWBH2575J5
1 KPWBH2510 KPWBH2510J5
Mercmaster

III HID 50-250 W


Enclosed and Gasketed Fixtures for Hazardous and Adverse Locations
Metal Halide 100 W, 175 W and 250 W
High Reactance, High Power Factor (min. P.F. 90%).
Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps.
UL Listed.
Simultaneous Exposure
Class I, Div. 2/Class II, Div. 1
(See Page F1-28 to F1-30 for group designations)
Class I, Div. 2; Groups A,B,C,D
Class I, Zone 2, AEx nA nR IIC
Class I, Zone 2, AEx nR IIC
Class II, Div. 1 and 2; Groups E,F,G
Class III
UL 1598A, UL 844, Marine Type Electric
Fixtures Outside Type (Salt Water)
UL 2279
NEMA 4X; IP66
1 For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
2 To order xtures with large globe change J5 to G3. To order NEMA Type I or Type III refractor, change J5 to J1 or J3 respectively.
3 Add the following voltage and frequency designations before Z2 or ZB sufx:
Sufx Voltage Frequency Notes
MT 120/208/240/277 60 Hz All
5MT 120/208/240/277/480 60 Hz 175 W, 250 W MH
FM 127/220 60 Hz 100 W MH
AM 127/220 60 Hz 175 W, 250 W MH
48 480 60 Hz All
GP 120/220/240 50 Hz 100 W MH
XQ 120/230 50 Hz 175 W, 250 W (MMIII400) MH
4 Add Z2 sufx for factory-sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB sufx for restricted breathing protection (AEx nR).
5 For xtures with guards, substitute G before adding voltage designation.
6 250 W Metal Halide and 200 W Pulse Start Metal Halide 50 Hz xtures use the Mercmaster III 400 ballast body.
Effective August, 2008
Copyright 2008
PAGE 36
800-621-1506
www.appletonelec.com

F1-36
F
Shown with Globe and Optional Guard
Hub
Size
(Inches)
Catalog Numbers 345
Type
Mounting
Lamp
Type
Lamp
Watts with Globe
with Type V 8 Refractor
or G3 Globe 2
25 Stanchion MH 100 1-1/4 KPSH10125 KPSH10125J5
One Hub 1-1/2 KPSH10150 KPSH10150J5
MH 175 1-1/4 KPSH17125 KPSH17125J5
1-1/2 KPSH17150 KPSH17150J5
MH 2506 1-1/4 KPSH25125 KPSH25125J5
1-1/2 KPSH25150 KPSH25150J5
90 Stanchion MH 100 1-1/4 KPSTH10125 KPSTH10125J5
One Hub 1-1/2 KPSTH10150 KPSTH10150J5
MH 175 1-1/4 KPSTH17125 KPSTH17125J5
1-1/2 KPSTH17150 KPSTH17150J5
MH 2506 1-1/4 KPSTH25125 KPSTH25125J5
1-1/2 KPSTH25150 KPSTH25150J5
Pendant Cone MH 100 3/4 KPCHH1075 KPCHH1075J5
One Hub,
Rigid Mounting
1 KPCHH1010 KPCHH1010J5
MH 175 3/4 KPCHH1775 KPCHH1775J5
1 KPCHH1710 KPCHH1710J5
MH 2506 3/4 KPCHH2575 KPCHH2575J5
1 KPCHH2510 KPCHH2510J5
Mercmaster

III HID 50-250 W


Enclosed and Gasketed Fixtures for Hazardous and Adverse Locations
Metal Halide 100 W, 175 W and 250 W
High Reactance, High Power Factor (min. P.F. 90%).
Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps.
UL Listed.
Simultaneous Exposure
Class I, Div. 2/Class II, Div. 1
(See Page F1-28 to F1-30 for group designations)
Class I, Div. 2; Groups A,B,C,D
Class I, Zone 2, AEx nA nR IIC
Class I, Zone 2, AEx nR IIC
Class II, Div. 1 and 2; Groups E,F,G
Class III
UL 1598A, UL 844, Marine Type Electric
Fixtures Outside Type (Salt Water)
UL 2279
NEMA 4X; IP66
1 For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
2 To order xtures with large globe change J5 to G3. To order NEMA Type I or Type III refractor, change J5 to J1 or J3 respectively.
3 Add the following voltage and frequency designations before Z2 or ZB sufx:
Sufx Voltage Frequency Notes
MT 120/208/240/277 60 Hz All
5MT 120/208/240/277/480 60 Hz 175 W, 250 W MH
FM 127/220 60 Hz 100 W MH
AM 127/220 60 Hz 175 W, 250 W MH
48 480 60 Hz All
GP 120/220/240 50 Hz 100 W MH
XQ 120/230 50 Hz 175 W, 250 W (MMIII400) MH
4 Add Z2 sufx for factory-sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB sufx for restricted breathing protection (AEx nR).
5 For xtures with guards, substitute G before adding voltage designation.
6 250 W Metal Halide and 200 W Pulse Start Metal Halide 50 Hz xtures use the Mercmaster III 400 ballast body.
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 37
F1-37
F
Hub
Size
(Inches)
Catalog Numbers 345
Type
Mounting
Lamp
Type
Lamp
Watts with Globe
with Type V 8 Refractor
or G3 Globe 2
Pendant PSMH 175 3/4 KPAP1775 KPAP1775J5
One Hub,
Rigid Mounting1
1 KPAP1710 KPAP1710J5
PSMH 2006 3/4 KPAP2075 KPAP2075J5
1 KPAP2010 KPAP2010J5
Ceiling PSMH 175 3/4 KPCP1775 KPCP1775J5
Five Hubs,
Four Close-Up Plugs
1 KPCP1710 KPCP1710J5
PSMH 2006 3/4 KPCP2075 KPCP2075J5
1 KPCP2010 KPCP2010J5
Wall PSMH 175 3/4 KPWBP1775 KPWBP1775J5
Five Hubs,
Four Close-Up Plugs
1 KPWBP1710 KPWBP1710J5
PSMH 2006 3/4 KPWBP2075 KPWBP2075J5
1 KPWBP2010 KPWBP2010J5
Mercmaster

III HID 50-250 W


Enclosed and Gasketed Fixtures for Hazardous and Adverse Locations
Pulse Start Metal Halide 175 W and 250 W
High Reactance, High Power Factor (min. P.F. 90%).
Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps.
UL Listed.
Simultaneous Exposure
Class I, Div. 2/Class II, Div. 1
(See Page F1-28 to F1-30 for group designations)
Class I, Div. 2; Groups A,B,C,D
Class I, Zone 2, AEx nA nR IIC
Class I, Zone 2, AEx nR IIC
Class II, Div. 1 and 2; Groups E,F,G
Class III
UL 1598A, UL 844, Marine Type Electric
Fixtures Outside Type (Salt Water)
UL 2279
NEMA 4X; IP66
1 For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
2 To order xtures with large globe change J5 to G3. To order NEMA Type I or Type III refractor, change J5 to J1 or J3 respectively.
3 Add the following voltage and frequency designations before Z2 or ZB sufx:
Sufx Voltage Frequency Notes
MT 120/208/240/277 60 Hz All
5MT 120/208/240/277/480 60 Hz 175 W, 200 W PSMH
48 480 60 Hz All
XQ 120/230 50 Hz 200 W (MMIII400) PSMH
4 Add Z2 sufx for factory-sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB sufx for restricted breathing protection (AEx nR).
5 For xtures with guards, substitute G before adding voltage designation.
6 250 W Metal Halide and 200 W Pulse Start Metal Halide 50 Hz xtures use the Mercmaster III 400 ballast body.
Effective August, 2008
Copyright 2008
PAGE 38
800-621-1506
www.appletonelec.com

F1-38
F
Shown with Globe and Optional Guard
Hub
Size
(Inches)
Catalog Numbers 345
Type
Mounting
Lamp
Type
Lamp
Watts with Globe
with Type V 8 Refractor
or G3 Globe 2
25 Stanchion PSMH 175 1-1/4 KPSP17125 KPSP17125J5
One Hub 1-1/2 KPSP17150 KPSP17150J5
PSMH 2006 1-1/4 KPSP20125 KPSP20125J5
1-1/2 KPSP20150 KPSP20150J5
90 Stanchion PSMH 175 1-1/4 KPSTP17125 KPSTP17125J5
One Hub 1-1/2 KPSTP17150 KPSTP17150J5
PSMH 2006 1-1/4 KPSTP20125 KPSTP20125J5
1-1/2 KPSTP20150 KPSTP20150J5
Pendant Cone PSMH 175 3/4 KPCHP1775 KPCHP1775J5
One Hub,
Rigid Mounting
1 KPCHP1710 KPCHP1710J5
PSMH 2006 3/4 KPCHP2075 KPCHP2075J5
1 KPCHP2010 KPCHP2010J5
Mercmaster

III HID 50-250 W


Enclosed and Gasketed Fixtures for Hazardous and Adverse Locations
Pulse Start Metal Halide 175 W and 250 W
High Reactance, High Power Factor (min. P.F. 90%).
Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps.
UL Listed.
Simultaneous Exposure
Class I, Div. 2/Class II, Div. 1
(See Page F1-28 to F1-30 for group designations)
Class I, Div. 2; Groups A,B,C,D
Class I, Zone 2, AEx nA nR IIC
Class I, Zone 2, AEx nR IIC
Class II, Div. 1 and 2; Groups E,F,G
Class III
UL 1598A, UL 844, Marine Type Electric
Fixtures Outside Type (Salt Water)
UL 2279
NEMA 4X; IP66
1 For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
2 To order xtures with large globe change J5 to G3. To order NEMA Type I or Type III refractor, change J5 to J1 or J3 respectively.
3 Add the following voltage and frequency designations before Z2 or ZB sufx:
Sufx Voltage Frequency Notes
MT 120/208/240/277 60 Hz All
5MT 120/208/240/277/480 60 Hz 175 W, 200 W PSMH
48 480 60 Hz All
XQ 120/230 50 Hz 200 W (MMIII400) PSMH
4 Add Z2 sufx for factory-sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB sufx for restricted breathing protection (AEx nR).
5 For xtures with guards, substitute G before adding voltage designation.
6 250 W Metal Halide and 200 W Pulse Start Metal Halide 50 Hz xtures use the Mercmaster III 400 ballast body.
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 39
F1-39
F
Mercmaster

III HID 50-250 W


PRE-PAK


Factory-Assembled Fixtures
For 70 W, 100 W or 150 W High Pressure Sodium Lamps, or
100 W or 175 W Metal Halide Lamps. Mogul Base Lamps.
These pre-packaged fixture compo-
nent combinations are delivered fully
assembled and packed in a single
carton. They are available with or
without lamp, and with choice of
globe or NEMA Type I, III or V refrac-
tors all with or without guards. PRE-
PAK units simplify ordering, stocking
and shipping, and result in savings on
job-site assembly and installation time
and costs.
Catalog numbers do not include
mounting hood. For mounting hood
selection, see Page F1-39 and order
separately. Hood will be packaged
separately.
To order reflectors for PRE-PAK
fixtures, see Page F1-40 and order
separately. Reflectors will be pack-
aged separately.
All catalog numbers above are fixtures without lamp. To order fixture complete with appropriate installed lamp, add suffix L to catalog number. All PRE-PAK
fixtures include multi-tap ballast for operation on 120 V, 208 V, 240 V or 277 V lines. Fixture component combinations listed are furnished completely as-
sembled in a single carton.
* Refractor catalog numbers listed are for NEMA Type I. To order fixture with Type III refractor, change J1 in catalog number to J3; for Type V refractor, change
J1 to J5.
100 W fixtures use ED-28 mogul base lamps.
Mercmaster III PRE-PAK Fixtures with Globe
Pendant
Cone
Ceiling
Wall
25 Stanchion
90 Stanchion
Lamp Type
and Watts
Ballast Assembly
with Globe Only
Ballast Assembly
with G3 Globe Only
Ballast Assembly
with Globe and Guard
100 W MH KPBU100H-MT KPBUG3100H-MT KPBU100HG-MT
175 W MH KPBU175H-MT KPBUG3175H-MT KPBU175HG-MT
70 W HPS KPBU70L-MT KPBUG370L-MT KPBU70LG-MT
100 W HPS KPBU100L-MT KPBUG3100L-MT KPBU100LG-MT
150 W HPS KPBU150L-MT KPBUG3150L-MT KPBU150LG-MT
Lamp Type
and Watts
Ballast Assembly
with Refractor Only*
Ballast Assembly
with Refractor and Guard
100 W MH KPBU100HJ1-MT KPBU100HJ1G-MT
175 W MH KPBU175HJ1-MT KPBU175HJ1G-MT
70W HPS KPBU70LJ1-MT KPBU70LJ1G-MT
100 W HPS KPBU100LJ1-MT KPBU100LJ1G-MT
150 W HPS KPBU150LJ-MT KPBU150LJ1G-MT
Mercmaster III PRE-PAK Fixtures
with NEMA Type 1, 3 and 5 Refractors*
Effective August, 2008
Copyright 2008
PAGE 40
800-621-1506
www.appletonelec.com

F1-40
F
Hazardous Location Photocontrols
Factory-Sealed
Applications
Encapsulated photocontrol provides
automatic dusk-to-dawn lighting
control in Class I, Div. 2 locations.
Typical applications include walk-
ways, security areas and any other
outdoor lighting application.
For use with Mercmaster III Low
Profile, Mercmaster III, and Merc-
master III 400 Series Luminaires.
For remote mounting in FS Boxes.
Features
Factory-sealed design eliminates the
need for an explosionproof enclosure.
Can be easily installed in the field.
Solid state design for performance
and reliability.
Available for 120, 208, 240, or 277
volts.
35-400 W H.I.D. incandescent or
fluorescent, 50/60 HZ.
1000 V.A. Voltage/Ampere
Minimum time delay: 15 seconds to
eliminate nuisiance tripping.
Turns fixture on at 3 footcandles, off
at 8 footcandles.
Provided with (3) 18AWG stranded
leads 6 in length.
Will fit through standard 1/2
knockout.
Materials
Encapsulated with epoxy sealing
compound.
FS Cover: aluminum
Compliances
Class I, Div. 2, Groups A,B,C,D
UL Standards: 1604 Hazardous
(Classified) Locations
NEMA 4X
PCD2 Series Hazardous Location Photocontrol
For use in Class I, Div. 2, Groups A,B,C,D locations.
Class I, Div. 2,
Groups A,B,C,D
Maintains Class I, Div. 2
rating for Mercmaster III
Low Profile, Mercmaster III,
and Mercmaster III 400
Series Luminaires
NEMA 4X
Ordering Information
1.13
(2.87 cm)
0.69
(1.75 cm)
1.94
(4.92 cm)
1.19
(3.02 cm)
1.375
(3.49cm)
2.56
(6.50 cm)
Factory-installed Photocontrol
Suffix Designation* Voltage Range
PC120 120 V, 50/60 Hz
PC208 208 V, 50/60 Hz
PC240 240 V, 50/60 Hz
Mercmaster III wall mounting hood with
photocontrol installed shown PC277 277 V, 50/60 Hz
Add to fixture catalog after voltage; i.e.: KPWBL1075MTPC12.
Photocontrol in FS cover for use with FS/FD box (Section B)
Catalog Number Voltage Range
FSKA-PC120D2 120V, 50/60 Hz
FSKA-PC247D2 208-277V, 50/60 Hz
Supplied with two stainless steel screws.
For neoprene gasket, order catalog number FS-GKR-1N.
Photocontrol for field installation
Catalog Number Max. Current Voltage Range
PC120D2 8.3 A 120 V, 50/60 Hz
PC247D2 3.5 A 208-277 V, 50/60 Hz
Dimensions
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 41
F1-41
F
Mercmaster

III HID 50-250 W


Mounting Hoods and Ballast Bodies
Hoods and Ballast Housings are Copper-Free Cast Aluminum (Less than 4/10 of 1%).
Mounting Hoods
Description
Hub Size
(Inches)
Catalog Number
Copper-Free Aluminum
Pendant
One Hub,
Rigid Mounting
3/4 KPA-75
1 KPA-100
Pendant (Flexible)
One Hub,
Flexible Mounting
3/4 KPAF-75
1 KPAF-100
Pendant Cone
One Hub,
Rigid Mounting
3/4 KPCH-75
1 KPCH-100
Ceiling
Five Hubs,
Four Close-Up Plugs
3/4 KPC-75
1 KPC-100
Wall
Five Hubs,
Four Close-Up Plugs
3/4 KPWB-75
1 KPWB-100
25 Stanchion
One Hub
1-1/4 KPS-125
1-1/2 KPS-150
90 Stanchion
One Hub
1-1/4 KPST-125
1-1/2 KPST-150
* Add -Z2 after voltage designation and/or option suffix for non-sparking/restricted breathing protection (AEx nA nR). Add -ZB for restricted breathing protection
(AEx nR).
Add the following options after voltage designation and before Z2 or ZB suffix: -S for Smart Starter; -SR for Smart Hot Restrike; -R after voltage designation
for ballast body with Hot Restrike Ignitor (see F1-40 for description).
Add -E after voltage designation and before Z2 or ZB suffix for ballast body with provision for Emergency Quartz Light (not suitable for hazardous locations).
100 W fixtures use ED-28 mogul base lamps only.
For 100 W HPS version fixtures only.
Ballast Body for
Glass Globe
Ballast Bodies
Type
Lamp
Watts
Catalog Numbers Voltage Suffixes*
For Globe
For G3 Globe/
Refractor MT 5MT FM AM FA 48 GP XQ GK
High Pressure Sodium 50 KPB50L KPBR50L X X X
High Power Factor 70 KPB70L KPBR70L X X X X
(Min. P.F. 90%) 100 KPB100L KPBR100L X X X X
150 KPB150L KPBR150L X X X X
Metal Halide 100 KPB100H KPBR100H X X X X
HX-High Power Factor 175 KPB175H KPBR175H X X X X X
(Min. P.F. 90%) 250 KPB250H KPBR250H X X X X X
Pulse Start Metal Halide 175 KPB175P KPBR175P X X X
Super Constant Wattage 200 KPB200P KPBR200P X X X X
(Min. P.F. 90%)
Voltage: -MT 120/208/240/277 V, 60 Hz
-AM 127/220 V, 60 Hz
-GP 120/220/240 V, 50 Hz
-5MT 120/208/240/277/480 V, 60 Hz
-FA 220 V, 60 Hz
-XQ 120/230 V, 50 Hz
-FM 127/220 V, 60 Hz
-48 480 V, 60 Hz
-GK 220/240 V, 50 Hz
Ballast Body for
Glass Refractor or
G3 Globe
Effective August, 2008
Copyright 2008
PAGE 42
800-621-1506
www.appletonelec.com

F1-42
F
Mercmaster

III HID 50-250 W


Accessories and Replacement Parts
Not U.L. Listed with reflectors. Consult factory if used with KPST or KPWB mounting hoods.
F
Item Description Catalog Number
White Polyester Reectors
50W-250W
For Globe Fixtures Standard Dome KR2-ST
30 Angle KR2-AN
For Refractor/G3 Fixtures Standard Dome CMR-4ST
30 Angle CMR-4AN
Prismatic Glass Globes
Heat-Resistant
Clear VPGL-2HR
Amber VPGL-2AM
Blue VPGL-2BL
Green VPGL-2GR
Red VPGL-2RE
Prismatic Glass Globe G3
Heat-Resistant
Clear VPGL3HR
Standard Dome
Glass Globe
30 Angle
G3 Glass Globe
Guards
Guards are die-cast copper-
free aluminum with baked
epoxy finish to match fixtures.
Fixture supplied with stainless
steel mounting screws which
thread into stainless steel
inserts on fixture housing to
attach guard. To order fixture
with guard, add suffix -G to
catalog number before adding
voltage suffix.
Reflectors
Standard dome and 30
angle polyester reflectors
are shown elsewhere in this
catalog section.
Hot Restrike
Instantly restrikes a hot HPS
lamp when power is restored
after a momentary outage.
Available factory-installed only.
To order, add suffix -R to
catalog number.
Quartz Emergency Light
When ordered, HPS fix-
tures will be supplied with a
prewired special DC bayonet
base socket to accept a
150W, 120V quartz lamp (not
furnished) that automatically
switches on when a power
outage occurs. Fixtures
ordered with this quartz
emergency lamp feature do
NOT comply with require-
ments for classified areas
and should be used only in
non-classified locations. To
order, add suffix -E to cata-
log number and specify if a
relay switch is desired.
Photocell and Fuses
Photocontrol shown on
F1-38 and fuses on F1-43.
Smart Starter (HPS only)
Performs as a conventional
starter in lamp start-up. Re-
moves itself from circuit at
end of lamp life or if lamp is
out of socket. Add suffix -S
to catalog number.
Smart Hot Restrike (HPS only)
Will immediately restrike
HPS lamp when power is
restored after a momentary
power interruption. The
smart function removes the
hot restrike ignitor from the
circuit if the lamp burns
out or is removed from the
socket. Eliminates starter
failures caused by prolonged
operation with cycling or fail-
ing lamps. Add suffix -SR to
catalog number.
Accessory Options
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 43
F1-43
F
Item Description Catalog Number
Tuff-Skin

Coated Prismatic Glass


Globes For Non-Classied Areas
For use in areas where xture is
subject to extreme thermal shock
Clear Heat-Resistant VPGL-2HRT
Polycarbonate Globes
Impact-Resistant**
Use 100 watt lamp max. Do not use in
ambients exceeding 25 C.
Clear VPGL-2PL
Amber VPGL-2AMPL
Green VPGL-2GRPL
Red VPGL-2REPL
Closed Prismatic Glass Refractors
50W-250W
NEMA Type I LPG-R1
All Heat-Resistant NEMA Type III LPG-R3
NEMA Type V LPG-R5
Closed Prismatic Polymeric
Refractors
Suitable for Class II, Div. 1 & 2, Groups
F & G, NEMA 4X, UL 1598A Marine
Type Electric Fixtures Outside Type
(Salt Water)
For use with MH lamps, 100W max.
40C max. ambient temperature.
NEMA Type II LPRF-2CP
NEMA Type III LPRF-3CP
NEMA Type IV LPRF-4CP
NEMA Type V LPRF-5CP
Copper-Free Aluminum Guards Globe Guard KGU2
G3 Globe/Refractor Guard KRG2
Replacement Gaskets
Silicone Rubber
Globe Gasket VPGL-GK
G3 Globe/Refractor Gasket KRF-GK
Retrot Pendant Mounting Adapter
Permits use of Mercmaster III pendant
hood with 3/4 hub on existing V-51
mounting hood.
LPAD-1
Refractor Guard
Globe Gasket
Globe Guard
Mounting Adapter
Mercmaster

III HID 50-250 W


Accessories and Replacement Parts
Glass Refractor
Polymeric Refractor
Polycarbonate
Globe
Tuff-Skin


Glass Globe
**Polycarbonate globes are shatter-resistant for use in processing plants, canneries, dairies, bakeries or anywhere broken glass would prove a hazard. Ide-
ally suited for areas where vandalism, high replacement and maintenance costs are a problem. Do not use in ambients exceeding 25 C. For burning in
vertical base-up positions only.
Effective August, 2008
Copyright 2008
PAGE 44
800-621-1506
www.appletonelec.com

F1-44
F
Ballast Housing Weights
Lamp
Watts
HPS
(Wt. Lbs.*)
MH/PSMH
(Wt. Lbs.*)
PSMH
(Wt. Lbs.*)
Globe Housing with Ballast
50 12-1/2
70 15
100 16
150 17
175 17 17-1/4
200 18
250 19
Refractor Housing with Ballast
50 13
70 15-1/2
100 16-1/2
150 17-1/2
175 17-1/2 17-3/4
200 18-1/2
250 19-1/2
Component and Accessory Weights
Item Wt. Lbs.*
Mounting Hoods
Pendant 2-1/4
Ceiling 3
Wall 4
25Stanchion 3-1/4
Straight Stanchion 3-1/3
Refractors, Globes & Guards
8 Glass Refractor 5-1/4
Glass Globe 3-3/4
Glass Globe 3-3/4
Globe Guard 1
Refractor Guard 1
Reflectors
Standard Dome 2-1/2
30Angle 2-1/2
Mercmaster

III HID 50-250 W


Ballast Housing, Component and Accessory Weights
* Weights are approximate.
Add 1 lb. for HPS fixtures with Hot Restrike. Add 1/4 lb. for Quartz Emergency Light.
MT Multi-Tap (120 V, 208 V, 240 V or 277 V).
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 45
F1-45
F
Mercmaster

III HID 50-250 W


Electrical Specifications and Fuse Kits
Electrical Specifications
C.W.A. Constant Wattage Autotransformer. HX-HPF High Reactance High Power Factor Autotransformer. Super C.W.A. Super Constant Wattage Autotransformer.
150 W HPS units equipped with ballasts to operate 55-volt lamps only.
Line
Voltage
Type of
Ballast
Starting
Amps
Operating
Amps
Total
Watts
50-Watt High Pressure Sodium
120 HX-HPF 0.58 0.58 64
208 HX-HPF 0.35 0.33 64
240 HX-HPF 0.31 0.29 64
277 HX-HPF 0.25 0.25 64
70-Watt High Pressure Sodium
120 HX-HPF 0.90 0.82 94
208 HX-HPF 0.50 0.48 94
240 HX-HPF 0.44 0.41 94
277 HX-HPF 0.35 0.36 94
480 HX-HPF 0.21 0.21 94
100-Watt High Pressure Sodium
120 HX-HPF 1.30 1.15 130
208 HX-HPF 0.76 0.67 130
240 HX-HPF 0.66 0.58 130
277 HX-HPF 0.60 0.50 130
480 HX-HPF 0.33 0.31 135
150-Watt High Pressure Sodium
120 HX-HPF 2.00 1.66 189
208 HX-HPF 1.16 0.96 189
240 HX-HPF 1.00 0.83 189
277 HX-HPF 0.88 0.75 189
480 HX-HPF 0.50 0.44 189
100-Watt Metal Halide
120 HX-HPF 1.20 1.15 130
208 HX-HPF 0.70 0.66 130
240 HX-HPF 0.61 0.58 130
277 HX-HPF 0.55 0.50 130
480 HX-HPF 0.30 0.35 140
175-Watt Metal Halide
120 C.W.A. 1.30 1.80 213
208 C.W.A. 0.75 1.10 213
240 C.W.A. 0.65 0.90 213
277 C.W.A. 0.55 0.80 213
480 C.W.A. 0.35 0.45 213
250-Watt Metal Halide
120 C.W.A. 1.20 2.60 295
208 C.W.A. 0.65 1.50 295
240 C.W.A. 0.60 1.30 295
277 C.W.A. 0.50 1.12 295
480 C.W.A. 0.30 0.65 295
Line
Voltage
Type of
Ballast
Starting
Amps
Operating
Amps
Total
Watts
175-Watt Pulse Start Metal Halide
120 Super C.W.A. 1.10 1.86 208
208 Super C.W.A. 0.75 1.23 208
240 Super C.W.A. 0.65 0.98 208
277 Super C.W.A. 0.55 0.87 208
480 C.W.A. 0.25 0.50 210
200-Watt Pulse Start Metal Halide
120 Super C.W.A. 1.15 2.20 232
208 Super C.W.A. 0.65 1.25 232
240 Super C.W.A. 0.55 1.10 232
277 Super C.W.A. 0.49 0.95 232
480 Super C.W.A. 0.19 0.54 232
Lamp
Watts Volts
Fuse
Quantity
Required
Fuse Kit Catalog Number
HPS MH PSMH
35 120 1 F2
50 120 1 F5 F3
208 2 F3 F3
240 2 F3 F2
277 1 F2 F2
70 120 1 F5 F4
208 2 F3 F3
240 2 F3 F3
277 1 F2 F2
480 2 F2 F1
100 120 1 F8 F6
208 2 F5 F4
240 2 F5 F3
277 1 F3 F3
480 2 F3 F2
150 120 1 F10
208 2 F5
240 2 F5
277 1 F5
480 2 F3
175 120 1 F5 F5
208 2 F3 F3
240 2 F3 F3
277 1 F2 F3
480 2 F2 F2
200 120 1 F6
208 2 F4
240 2 F3
277 1 F3
480 2 F3
Fuse Kit
Effective August, 2008
Copyright 2008
PAGE 46
800-621-1506
www.appletonelec.com

F1-46
F
Mercmaster

III HID 50-250 W


Dimensions
50 W-150 W HPS, 100-250 W MH and 175 W and 200 W PSMH.
"
"
"
Pendant
(Rigid or Flex)
Ceiling Cone
Wall
90 Straight Stanchion
8 Globe/Refractor
Body/Guard
Polymeric Refractor
25 Angle Stanchion
2.03
.31 Diameter Hole
4.06
3.36

1.68 1.68
5.5

11.00

5.87

17.23

9.79
10.93
17.00
5.5
11.00

5.87

Globe/Guard/Refractor
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 47
F1-47
F
* Photometric data is based on fixtures with 150-watt
clear High Pressure Sodium lamp (16,000 lumen).
For candlepower values of fixtures with other HPS
lamps, use the following multipliers: for 100 W
(9,500 lumen) HPS lamp 0.594; for 70 W (6,400
lumen) HPS lamp 0.40; for 50 W (4,000 lumen)
HPS lamp 0.25. For candlepower values of fixture
with guard, multiply by 0.95.
Mercmaster

III HID 50-250 W


Photmetric Data
With 150-Watt High Pressure Sodium Lamp.
Zone Lumens Total Luminaire Efficiency = 86.1%
REPORT NUMBER: KP15LG 0-10 50.74 CIE Type Semi-Direct
10-20 164.55
Plane
Spacing
Criteria
Lamps: 150 W High Pressure Sodium with Globe only*
20-30 310.47
30-40 611.05 0-180 2.82 Coefficients of Utilization Zonal Cavity Method
40-50 961.13 90-270 2.82 Effective Floor Cavity Reflectance 0.20
50-60 1308.18 Diagonal 2.80 % Ceiling Rcc 80 70 50 30 10 0
60-70 1542.35 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 1716.10 Zonal Lumen Summary 0 95 95 95 95 89 89 89 89 77 77 77 67 67 67 57 57 57 53
80-90 1799.18 Zone Lumens % Lamp % Fixture 1 81 74 69 64 75 69 64 59 59 55 51 50 47 44 42 39 37 33
90-100 1802.19 0-30 525.75 3.3 3.8 2 71 62 54 47 65 57 50 44 49 43 38 41 36 32 33 30 27 23
100-110 1676.86 0-40 1136.81 7.1 8.3 3 64 52 44 37 58 48 41 34 41 35 30 34 29 25 28 24 20 17
110-120 1379.11 0-60 3406.12 21.3 24.7 4 57 45 36 30 53 42 34 28 35 29 24 29 24 20 24 19 16 13
120-130 441.46 0-90 8463.75 52.9 61.4 5 52 40 31 24 48 37 29 23 31 24 19 26 20 16 21 16 13 10
130-140 9.61 90-120 4858.16 30.4 35.3 6 48 35 26 20 44 32 25 19 27 21 16 23 17 13 18 14 11 8
140-150 3.33 90-130 5299.62 33.1 38.5 7 44 31 23 17 40 29 21 16 24 18 14 20 15 11 16 12 9 7
150-160 0.74 90-150 5312.56 33.2 38.5 8 40 28 20 15 37 26 19 14 22 16 12 18 13 10 15 11 8 6
160-170 0.00 90-180 5313.30 33.2 38.6 9 38 25 18 13 35 24 17 12 20 14 10 17 12 8 14 10 7 5
170-180 0.00 180-0 13777.05 86.1 100.0 10 35 23 16 11 32 22 15 11 18 13 9 15 11 7 13 9 6 4
Zone Lumens Total Luminaire Efficiency = 73.6%
REPORT NUMBER: KP15LST 0-10 266.98 CIE Type - Direct
10-20 799.41
Plane
Spacing
Criteria
Lamps: 150 W High Pressure Sodium with
Standard Dome Reflector*
20-30 1337.05
30-40 1732.06 0-180 1.46 Coefficients of Utilization - Zonal Cavity Method
40-50 2067.60 90-270 1.46 Effective Floor Cavity Reflectance 0.20
50-60 2317.60 Diagonal 1.68 % Ceiling Rcc 80 70 50 30 10 0
60-70 2210.81 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 866.77 Zonal Lumen Summary 0 88 88 88 88 86 86 86 86 82 82 82 78 78 78 75 75 75 73
80-90 145.09 Zone Lumens % Lamp % Fixture 1 79 76 72 69 77 74 71 68 71 68 66 68 66 64 65 64 62 60
90-100 14.46 0-30 2403.44 15.0 20.4 2 71 65 59 55 69 63 58 54 61 57 53 58 55 52 56 53 50 49
100-110 8.75 0-40 4135.50 25.8 35.1 3 64 56 49 44 62 55 49 44 52 47 43 50 46 42 48 45 41 40
110-120 7.93 0-60 8520.70 53.3 72.3 4 58 49 42 36 57 48 41 36 46 40 36 44 39 35 42 38 35 33
120-130 4.51 0-90 11743.37 73.4 99.7 5 53 43 36 31 52 42 35 30 40 35 30 39 34 30 38 33 29 28
130-140 2.16 90-120 31.14 0.2 0.3 6 49 38 31 26 47 38 31 26 36 30 26 35 30 25 34 29 25 24
140-150 0.48 90-130 35.65 0.2 0.3 7 45 34 27 23 44 34 27 23 33 27 22 31 26 22 30 26 22 20
150-160 0.00 90-150 38.29 0.2 0.3 8 42 31 24 20 40 31 24 20 30 24 20 29 23 19 28 23 19 18
160-170 0.00 90-180 38.29 0.2 0.3 9 39 28 22 18 38 28 22 18 27 21 17 26 21 17 25 21 17 16
170-180 0.00 180-0 11781.65 73.6 100.0 10 36 26 20 16 35 26 20 16 25 19 16 24 19 16 23 19 15 14
Effective August, 2008
Copyright 2008
PAGE 48
800-621-1506
www.appletonelec.com

F1-48
F
Mercmaster

III HID 50-250 W


Photmetric Data
With 150-Watt High Pressure Sodium Lamp.
* Photometric data is based on fixtures with 150-watt
clear High Pressure Sodium lamp (16,000 lumen).
For candlepower values of fixtures with other HPS
lamps, use the following multipliers: for 100 W
(9,500 lumen) HPS lamp 0.594; for 70 W (6,400
lumen) HPS lamp 0.40; for 50 W (4,000 lumen)
HPS lamp 0.25. For candlepower values of fixture
with guard, multiply by 0.95.
Zone Lumens Total Luminaire Efficiency = 73.1%
REPORT NUMBER: KP15LAN 0-10 222.62 CIE Type - Direct
10-20 664.6
Plane
Spacing
Criteria
Lamps: 150 W High Pressure Sodium with
30 Angle Dome Reflector*
20-30 1084.32
30-40 1536.55 0-180 2.06 Coefficients of Utilization - Zonal Cavity Method
40-50 1771.90 90-270 1.58 Effective Floor Cavity Reflectance 0.20
50-60 1771.51 Diagonal 1.62 % Ceiling Rcc 80 70 50 30 10 0
60-70 1668.93 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 1422.36 Zonal Lumen Summary 0 86 86 86 86 84 84 84 84 79 79 79 75 75 75 71 71 71 70
80-90 994.54 Zone Lumens % Lamp % Fixture 1 76 71 67 63 73 69 65 62 65 62 59 62 59 57 58 56 54 52
90-100 432.23 0-30 1971.54 12.3 16.9 2 68 60 54 49 65 58 53 48 55 50 46 52 48 45 49 46 43 41
100-110 104.58 0-40 3508.09 21.9 30.0 3 61 52 45 39 59 50 44 39 48 42 37 45 40 36 43 39 35 33
110-120 20.99 0-60 7051.50 44.1 60.3 4 55 45 38 32 53 44 37 32 42 36 31 39 34 30 37 33 29 27
120-130 1.21 0-90 11137.33 69.6 95.2 5 50 40 33 27 49 39 32 27 37 31 26 35 30 25 33 29 25 23
130-140 0.04 90-120 557.80 3.5 4.8 6 46 36 28 23 45 35 28 23 33 27 22 31 26 22 30 25 21 20
140-150 0.00 90-130 559.01 3.5 4.8 7 43 32 25 20 41 31 25 20 30 24 19 28 23 19 27 22 19 17
150-160 0.00 90-150 559.04 3.5 4.8 8 40 29 22 18 38 28 22 17 27 21 17 26 21 17 25 20 16 15
160-170 0.00 90-180 559.04 3.5 4.8 9 37 26 20 16 36 26 20 16 25 19 15 24 19 15 23 18 15 13
170-180 0.00 180-0 11696.38 73.1 100.0 10 35 24 18 14 33 24 18 14 23 17 14 22 17 13 21 16 13 12
Zone Lumens Total Luminaire Efficiency = 81.1%
REPORT NUMBER: KP15LJR5 0-10 72.83 CIE Type - Semi- Direct
10-20 222.26
Plane
Spacing
Criteria
Lamps: 150 W High Pressure Sodium with
8 Prismatic Glass Refracter - NEMA Type V*
20-30 380.73
30-40 621.11 0-180 1.98 Coefficients of Utilization - Zonal Cavity Method
40-50 852.53 90-270 1.98 Effective Floor Cavity Reflectance 0.20
50-60 1765.29 Diagonal 3.40 % Ceiling Rcc 80 70 50 30 10 0
60-70 3192.58 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 2366.61 Zonal Lumen Summary 0 93 93 93 93 89 89 89 89 82 82 82 76 76 76 70 70 70 67
80-90 1230.65 Zone Lumens % Lamp % Fixture 1 80 73 68 63 76 70 65 61 64 60 56 58 55 52 53 50 48 45
90-100 450.14 0-30 675.83 4.2 5.2 2 69 59 51 45 65 56 49 43 51 45 40 46 41 37 41 37 34 31
100-110 712.41 0-40 1296.93 8.1 10.0 3 61 49 40 33 57 47 38 32 42 35 29 38 32 27 34 29 25 22
110-120 499.15 0-60 3914.76 24.5 30.2 4 54 42 32 25 51 40 31 24 35 28 22 32 26 21 28 23 19 16
120-130 323.44 0-90 10704.60 66.9 82.5 5 49 36 27 20 46 34 26 19 31 23 18 27 21 16 24 19 15 12
130-140 185.00 90-120 1661.70 10.4 12.8 6 45 32 23 16 42 30 22 16 27 20 14 24 18 13 21 16 12 10
140-150 81.31 90-130 1985.14 12.4 15.3 7 41 28 20 14 38 27 19 13 24 17 12 21 15 11 19 14 10 8
150-160 21.08 90-150 2251.45 14.1 15.3 8 38 25 17 12 36 24 16 11 22 15 10 19 14 9 17 12 8 6
160-170 2.81 90-180 2275.34 14.2 17.5 9 35 23 15 10 33 22 15 10 20 13 9 18 12 8 16 11 7 5
170-180 0.00 180-0 12979.94 81.1 100.0 10 33 21 14 9 31 20 13 9 18 12 8 16 11 7 15 10 6 5
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 49
F1-49
F
Mercmaster

III HID 50-250 W


Photmetric Data
For 175-Watt Metal Halide and Pulse Start Metal Halide Lamps
* Photometric data is based on fixtures with a 175-
watt clear Metal Halide lamp (14,000 lumen). For
candlepower values of fixtures with other MH
lamps, use the following multipliers: for a 250
W (20,500 lumen) MH lamp 1.46; for a 100 W
(8,500 lumen) MH lamp 0.55. For Pulse Start
Metal Halide lamps, use the following: for a 175 W
(16,400 lumen) PSMH lamp 1.25; for a 200 W
(21,000 lumen) PSMH lamp 1.5. For candlepow-
er values of fixture with guard, multiply by 0.95.
Zone Lumens Total Luminaire Efficiency = 75.4%
REPORT NUMBER: KP17HG 0-10 34.14 CIE Type - General Diffuse
10-20 121.01 Lamps: 175 W Metal Halide with Globe only*
20-30 244.79
30-40 470.23 Coefficients of Utilization - Zonal Cavity Method
40-50 704.46 Effective Floor Cavity Reflectance 0.20
50-60 891.60 % Ceiling Rcc 80 70 50 30 10 0
60-70 1045.37 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 1254.42 Zonal Lumen Summary 0 82 82 82 82 77 77 77 77 66 66 66 57 57 57 48 48 48 44
80-90 1376.19 Zone Lumens % Lamp % Fixture 1 70 65 60 55 65 60 56 52 51 47 44 42 40 37 35 33 31 27
90-100 1438.00 0-30 399.94 2.9 3.8 2 62 54 47 42 57 50 44 39 42 37 33 35 31 28 28 25 22 19
100-110 1400.16 0-40 870.17 6.2 8.2 3 55 46 38 33 51 42 36 30 35 30 26 29 25 21 23 20 17 14
110-120 1247.31 0-60 2466.24 17.6 23.4 4 50 40 32 26 46 37 30 24 31 25 21 25 21 17 20 16 13 11
120-130 312.87 0-90 6142.22 43.9 58.2 5 46 35 27 22 42 32 25 20 27 21 17 22 17 14 17 14 11 8
130-140 6.25 90-120 4085.47 29.2 38.7 6 42 31 23 18 38 28 22 17 24 18 14 20 15 12 15 12 9 7
140-150 2.55 90-130 4398.34 31.4 41.7 7 38 27 20 15 35 25 19 14 21 16 12 18 13 10 14 10 8 6
150-160 0.48 90-150 4407.14 31.5 41.7 8 35 25 18 13 32 23 17 12 19 14 10 16 12 9 13 9 7 5
160-170 0.14 90-180 4407.77 31.5 41.8 9 33 22 16 12 30 21 15 11 17 13 9 14 10 7 12 8 6 4
170-180 0.00 180-0 10549.99 75.4 100.0 10 31 20 14 10 28 19 13 9 16 11 8 13 9 7 11 7 5 3
Zone Lumens Total Luminaire Efficiency = 63.8%
REPORT NUMBER: KP17HST 0-10 217.38 CIE Type - Direct
10-20 654.00
Plane
Spacing
Criteria
Lamps: 175 W Metal Halide with
Standard Dome Reflector*
20-30 1114.02
30-40 1399.97 0-180 1.50 Coefficients of Utilization - Zonal Cavity Method
40-50 1635.86 90-270 1.50 Effective Floor Cavity Reflectance 0.20
50-60 1697.00 Diagonal 1.66 % Ceiling Rcc 80 70 50 30 10 0
60-70 1489.94 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 576.37 Zonal Lumen Summary 0 76 76 76 76 74 74 74 74 71 71 71 68 68 68 65 65 65 64
80-90 113.51 Zone Lumens % Lamp % Fixture 1 69 66 63 61 67 65 62 60 62 60 58 59 57 56 57 55 54 53
90-100 11.73 0-30 1985.40 14.2 22.2 2 62 57 52 48 61 56 51 48 53 50 47 51 48 46 49 47 45 43
100-110 6.62 0-40 3385.37 24.2 37.9 3 56 49 44 39 55 48 43 39 46 42 38 45 41 38 43 40 37 35
110-120 7.66 0-60 6718.24 48.0 75.2 4 51 43 37 33 50 42 37 33 41 36 32 39 35 32 38 34 31 30
120-130 4.55 0-90 8898.06 63.6 99.6 5 47 38 32 28 45 37 32 28 36 31 27 35 30 27 33 30 27 25
130-140 2.51 90-120 26.01 0.2 0.3 6 43 34 28 24 42 33 28 24 32 27 23 31 27 23 30 26 23 22
140-150 1.74 90-130 30.56 0.2 0.3 7 40 31 25 21 39 30 25 21 29 24 20 28 24 20 27 23 20 19
150-160 1.37 90-150 34.81 0.2 0.3 8 37 28 22 18 36 27 22 18 26 22 18 26 21 18 25 21 18 16
160-170 1.36 90-180 37.82 0.3 0.4 9 34 25 20 16 33 25 20 16 24 19 16 23 19 16 23 19 16 15
170-180 0.29 180-0 8935.88 63.8 100.0 10 32 23 18 15 31 23 18 15 22 18 14 22 17 14 21 17 14 13
Effective August, 2008
Copyright 2008
PAGE 50
800-621-1506
www.appletonelec.com

F1-50
F
* Photometric data is based on fixtures with a 175-
watt clear Metal Halide lamp (14,000 lumen). For
candlepower values of fixtures with other MH
lamps, use the following multipliers: for a 250
W (20,500 lumen) MH lamp 1.46; for a 100 W
(8,500 lumen) MH lamp 0.55. For Pulse Start
Metal Halide lamps, use the following: for a 175 W
(16,400 lumen) PSMH lamp 1.25; for a 200 W
(21,000 lumen) PSMH lamp 1.5. For candlepow-
er values of fixture with guard, multiply by 0.95.
Mercmaster

III HID 50-250 W


Photmetric Data
For 175-Watt Metal Halide and Pulse Start Metal Halide Lamps
Zone Lumens Total Luminaire Efficiency = 61.6%
REPORT NUMBER: KP17HAN 0-10 176.81 CIE Type - Direct
10-20 539.59
Plane
Spacing
Criteria
Lamps: 175 W Metal Halide with
30 Angle Dome Reflector*
20-30 889.43
30-40 1215.31 0-180 2.02 Coefficients of Utilization - Zonal Cavity Method
40-50 1357.71 90-270 1.62 Effective Floor Cavity Reflectance 0.20
50-60 1315.82 Diagonal 1.58 % Ceiling Rcc 80 70 50 30 10 0
60-70 1166.27 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 999.07 Zonal Lumen Summary 0 73 73 73 73 71 71 71 71 67 67 67 64 64 64 61 61 61 59
80-90 651.96 Zone Lumens % Lamp % Fixture 1 64 61 57 54 62 59 56 53 56 53 51 53 51 49 50 49 47 45
90-100 224.27 0-30 1605.82 11.5 18.6 2 58 52 46 42 56 50 45 42 47 44 40 45 42 39 43 40 38 36
100-110 70.03 0-40 2821.13 20.2 32.7 3 52 45 39 34 50 43 38 34 41 36 33 39 35 32 37 34 31 29
110-120 13.33 0-60 5494.63 39.2 63.7 4 47 39 33 28 46 38 32 28 36 31 27 34 30 27 33 29 26 24
120-130 1.00 0-90 8311.95 59.4 96.4 5 43 34 28 24 42 34 28 24 32 27 23 30 26 23 29 25 22 21
130-140 0.05 90-120 307.62 2.2 3.6 6 40 31 25 20 38 30 24 20 29 24 20 27 23 20 26 22 19 18
140-150 0.05 90-130 308.62 2.2 3.6 7 37 28 22 18 35 27 22 18 26 21 17 25 20 17 24 20 17 15
150-160 0.00 90-150 308.72 2.2 3.6 8 34 25 20 16 33 25 19 16 24 19 15 23 18 15 22 18 15 14
160-170 0.00 90-180 308.72 2.2 3.6 9 32 23 18 14 31 23 17 14 22 17 14 21 17 13 20 16 13 12
170-180 0.00 180-0 8620.67 61.6 100.0 10 30 21 16 13 29 21 16 12 20 15 12 19 15 12 18 15 12 11
Zone Lumens Total Luminaire Efficiency = 73.9%
REPORT NUMBER: KP17HJR5 0-10 46.88 CIE Type - Semi-Direct
10-20 143.90
Plane
Spacing
Criteria
Lamps: 175 W Metal Halide with
8 Prismatic Glass Refracter - NEMA Type V*
20-30 253.40
30-40 435.19 0-180 2.08 Coefficients of Utilization - Zonal Cavity Method
40-50 581.59 90-270 2.08 Effective Floor Cavity Reflectance 0.20
50-60 1156.33 Diagonal 3.78 % Ceiling Rcc 80 70 50 30 10 0
60-70 2929.07 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 1945.94 Zonal Lumen Summary 0 85 85 85 85 82 82 82 82 75 75 75 69 69 69 64 64 64 61
80-90 1081.31 Zone Lumens % Lamp % Fixture 1 72 66 61 56 68 63 58 54 57 54 50 52 49 46 47 45 43 40
90-100 382.24 0-30 444.18 3.2 4.3 2 62 53 46 39 59 51 44 38 46 40 35 41 36 32 37 33 30 27
100-110 573.81 0-40 879.37 6.3 8.5 3 55 44 35 29 51 41 34 28 37 31 25 33 28 23 30 25 21 19
110-120 379.25 0-60 2617.28 18.7 25.3 4 49 37 28 22 46 35 27 21 31 24 19 28 22 17 25 20 16 13
120-130 235.75 0-90 8573.60 61.2 82.9 5 44 32 23 17 41 30 22 16 27 20 15 24 18 14 21 16 12 10
130-140 130.46 90-120 1335.30 9.5 12.9 6 40 28 20 14 37 26 19 13 24 17 12 21 15 11 19 14 10 8
140-150 56.32 90-130 1570.05 11.2 15.2 7 37 25 17 12 34 23 16 11 21 15 10 19 13 9 17 12 8 6
150-160 14.79 90-150 1756.84 12.5 15.2 8 34 22 15 10 32 21 14 9 19 13 8 17 12 8 15 10 7 5
160-170 2.06 90-180 1773.68 12.7 17.1 9 31 20 13 8 30 19 13 8 17 11 7 16 10 7 14 9 6 4
170-180 0.00 180-0 10347.28 73.9 100.0 10 29 18 12 7 28 18 11 7 16 10 6 14 9 6 13 8 5 4
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 51
F1-51
F
Degree Candela Lumens TOTAL LUMINAIRE EFFICIENCY = 70.8%
REPORT NUMBER: KPB175PG3
Lamps: 175 W Pulse Start Metal Halide ED28 Mogul Base with
G3 Globe only
0 657 CIE Type Semi-Direct
5 668 65 Spacing Criteria: 1.7
15 784 224
25 966 451
35 1194 705 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
45 871 711 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
55 1267 1142 RC 80 70 50 30 10 0
65 1309 1303 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
75 1430 1509 0 78 78 78 78 73 73 73 73 64 64 64 56 56 56 48 48 48 44
85 1528 1661 1 67 61 57 53 62 57 53 49 49 46 43 42 39 37 35 33 31 28
90 1537 ZONAL LUMEN SUMMARY 2 59 51 45 40 54 48 42 37 41 36 32 34 31 27 28 26 23 20
95 1552 1680 ZONE LUMENS %LAMP %FIXT. 3 53 44 37 31 49 40 34 29 34 29 25 29 25 21 24 21 18 15
105 1452 1532 0-30 740 4.2 6.0 4 48 38 31 25 44 35 29 24 30 25 20 25 21 17 21 17 14 12
115 1339 1232 0-40 1445 8.3 11.7 5 43 33 26 21 40 31 24 20 26 21 17 22 18 14 18 15 12 9
125 68 143 0-60 3297 18.8 26.6 6 40 29 23 18 37 27 21 16 23 18 14 20 15 12 16 13 10 8
135 19 16 0-90 7770 44.4 62.7 7 37 26 20 15 34 25 18 14 21 16 12 18 13 10 15 11 9 7
145 13 11 90-120 4444 25.4 35.9 8 34 24 17 13 31 22 16 12 19 14 11 16 12 9 13 10 7 6
155 7 3 90-130 4586 26.2 37.0 9 32 22 16 11 29 20 15 11 17 13 9 15 11 8 12 9 7 5
165 1 1 90-150 4613 26.4 37.2 10 29 20 14 10 27 18 13 9 16 11 8 14 10 7 11 8 6 4
175 2 0 90-180 4617 26.4 37.3
180 7 0-180 12387 70.8 100.0
Degree Candela Lumens TOTAL LUMINAIRE EFFICIENCY = 65.6%
REPORT NUMBER: KPB175PG3_ST
Lamps: 175 W Pulse Start Metal Halide ED28 Mogul Base with
G3 Globe and Standard Dome Reflector
0 2785 CIE Type Direct
950
1500
2850
0 15 30
90
75
60
45
5 2797 269 Spacing Criteria: 1.5
15 2902 823
25 2931 1358
35 2979 1821 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
45 2388 1874 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
55 2393 2145 RC 80 70 50 30 10 0
65 2044 2034 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
75 664 856 0 78 78 78 78 76 76 76 76 73 73 73 69 69 69 66 66 66 65
85 150 183 1 71 67 64 62 69 66 63 61 63 61 59 60 58 57 58 56 55 53
90 24 ZONAL LUMEN SUMMARY 2 64 58 53 49 62 57 52 48 54 50 47 52 49 46 50 47 45 43
95 5 11 ZONE LUMENS %LAMP %FIXT. 3 58 50 44 40 56 49 44 39 47 42 39 45 41 38 43 40 37 35
105 16 17 0-30 2450 14.0 21.3 4 52 44 38 33 51 43 37 33 41 36 32 39 35 32 38 34 31 29
115 91 73 0-40 4271 24.4 37.2 5 48 39 32 28 46 38 32 28 36 31 27 35 30 27 34 30 26 25
125 5 9 0-60 8290 47.4 72.2 6 44 35 28 24 42 34 28 24 33 27 23 31 27 23 30 26 23 21
135 7 3 0-90 11363 64.9 99.0 7 40 31 25 21 39 30 25 21 29 24 20 28 24 20 27 23 20 19
145 8 2 90-120 101 0.6 0.9 8 37 28 22 18 36 28 22 18 27 22 18 26 21 18 25 21 18 16
155 2 2 90-130 110 0.6 1.0 9 35 26 20 16 34 25 20 16 24 19 16 24 19 16 23 19 16 15
165 2 0 90-150 115 0.7 1.0 10 33 24 18 15 32 23 18 15 23 18 14 22 17 14 21 17 14 13
175 2 1 90-180 118 0.7 1.0
180 11 0-180 11481 65.6 100.0
Candela Distribution TOTAL LUMINAIRE EFFICIENCY = 58.2%
REPORT NUMBER: KPB175PG3_AN
Lamps: 175 W Pulse Start Metal Halide ED28 Mogul Base with
G3 Globe and 30 Angle Dome Reflector
0.0 45.0 90.0 135.0 180.0 Flux CIE Type Direct
0-deg
90-deg
180-deg L
E
G
E
N
D
0 2333 2333 2333 2333 2333
Plane
Spacing
Criteria 5 2491 2467 2321 2205 2141 223
15 2904 2753 2337 2160 2099 692 0 1.8
25 3010 2891 2480 2242 2120 1170 90 1.5 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
35 3471 3100 2544 2027 1367 1512 180 1.1 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
45 2978 2719 1993 832 546 1427 RC 80 70 50 30 10 0
55 3296 2939 1791 421 154 1533 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
65 3153 2801 776 74 0 1349 0 69 69 69 69 67 67 67 67 63 63 63 60 60 60 57 57 57 56
75 3175 2621 392 3 0 1140 1 61 57 54 51 59 56 53 50 53 50 48 50 48 46 48 46 45 43
85 2729 967 117 5 0 709 2 55 49 44 40 53 48 43 40 45 42 38 43 40 37 41 38 36 34
90 1601 662 11 5 5 ZONAL LUMEN SUMMARY 3 49 42 37 33 48 41 36 32 39 35 31 37 34 31 35 32 30 28
95 790 461 3 11 16 247 ZONE LUMENS %LAMP %FIXT 4 45 37 32 27 43 36 31 27 34 30 26 33 29 26 31 28 25 24
105 413 175 11 19 21 109 0-30 2085 11.9 20.5 5 41 33 27 23 40 32 27 23 31 26 22 29 25 22 28 24 21 20
115 117 8 8 29 90 56 0-40 3597 20.6 35.3 6 38 30 24 20 37 29 24 20 28 23 19 26 22 19 25 22 19 17
125 5 11 13 13 11 2 0-60 6557 37.5 64.4 7 35 27 21 18 34 26 21 17 25 20 17 24 20 17 23 19 16 15
135 0 3 3 3 0 1 0-90 9755 55.7 95.8 8 33 24 19 16 32 24 19 15 23 18 15 22 18 15 21 17 15 13
145 5 5 11 5 0 4 90-120 412 2.4 4.1 9 30 22 17 14 29 22 17 14 21 17 14 20 16 13 19 16 13 12
155 0 3 5 5 0 2 90-130 415 2.4 4.1 10 28 20 16 12 28 20 15 12 19 15 12 19 15 12 18 14 12 11
165 5 3 8 5 0 1 90-150 420 2.4 4.1
175 0 5 3 3 0 0 90-180 423 2.4 4.2
180 6 6 6 6 6 0-180 10178 58.2 100.0
Mercmaster

III HID 50-250 W


Photmetric Data
For Pulse Start Metal Halide Lamps
Effective August, 2008
Copyright 2008
PAGE 52
800-621-1506
www.appletonelec.com

F1-52
F
Degree Candela Lumens TOTAL LUMINAIRE EFFICIENCY = 74.9%
REPORT NUMBER: KPB175HG3_ST
Lamps: 175 W Metal Halide ED28 Mogul Base with
G3 Globe only
0 430 CIE Type Semi-Direct
5 434 43 Spacing Criteria: 1.8
15 553 160
25 717 341
35 925 531 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
45 666 533 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
55 1009 906 RC 80 70 50 30 10 0
65 1082 1073 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
75 1163 1229 0 83 83 83 83 77 77 77 77 68 68 68 59 59 59 51 51 51 47
85 1215 1324 1 70 65 60 55 65 60 56 52 52 48 45 44 41 39 37 35 33 29
90 1209 Zonal Lumen Summary 2 62 54 47 41 57 50 44 39 43 38 34 36 32 29 30 27 24 21
95 1216 1322 ZONE LUMENS % LAMP % FIXT. 3 56 46 38 32 51 43 36 30 36 31 26 30 26 22 25 21 18 15
105 1126 1188 0-30 543 4.2 5.6 4 50 40 32 26 46 37 30 24 31 26 21 26 22 18 21 18 15 12
115 999 944 0-40 1074 8.3 11.0 5 46 35 27 22 42 32 25 20 28 22 17 23 18 15 19 15 12 10
125 53 120 0-60 2513 19.3 25.8 6 42 31 23 18 39 29 22 17 24 19 15 21 16 12 17 13 10 8
135 17 11 0-90 6139 47.2 63.1 7 39 28 21 16 35 26 19 15 22 17 13 18 14 11 15 12 9 7
145 14 8 90-120 3453 26.6 35.5 8 36 25 18 13 33 23 17 13 20 15 11 17 12 9 14 10 8 6
155 2 3 90-130 3574 27.5 36.7 9 33 23 16 12 31 21 15 11 18 13 10 15 11 8 13 9 7 5
165 0 0 90-150 3593 27.6 36.9 10 31 21 14 10 29 19 14 10 17 12 8 14 10 7 12 8 6 4
175 1 0 90-180 3597 27.7 36.9
180 1 0-180 9735 74.9 100.0
Degree Candela Lumens TOTAL LUMINAIRE EFFICIENCY = 64.0%
REPORT NUMBER: KPB175HG3_ST
Lamps: 175 W Metal Halide ED28 Mogul Base with
G3 Globe and Standard Dome Reflector
0 1901 CIE Type Direct
5 1906 183 Spacing Criteria: 1.5
15 2008 571
25 2053 956
35 2153 1291 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
45 1680 1320 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
55 1777 1592 RC 80 70 50 30 10 0
65 1590 1572 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
75 479 640 0 76 76 76 76 74 74 74 74 71 71 71 68 68 68 65 65 65 64
85 106 132 1 69 66 63 60 67 64 61 59 61 59 57 59 57 55 56 55 53 52
90 15 Zonal Lumen Summary 2 62 56 51 47 60 55 51 47 53 49 46 50 47 44 48 46 43 42
95 0 3 ZONE LUMENS % LAMP % FIXT. 3 56 49 43 38 54 47 42 38 45 41 37 43 40 36 42 38 36 34
105 7 4 0-30 1710 13.2 20.5 4 51 42 36 32 49 41 36 31 40 35 31 38 34 30 37 33 30 28
115 61 51 0-40 3001 23.1 36.1 5 46 37 31 27 45 37 31 26 35 30 26 34 29 26 32 28 25 24
125 2 6 0-60 5913 45.5 71.0 6 42 33 27 23 41 33 27 23 31 26 22 30 26 22 29 25 22 20
135 0 1 0-90 8257 63.5 99.2 7 39 30 24 20 38 29 24 20 28 23 19 27 23 19 26 22 19 18
145 0 1 90-120 58 0.4 0.7 8 26 27 21 17 35 27 21 17 26 21 17 25 20 17 24 20 17 15
155 1 0 90-130 64 0.5 0.8 9 34 25 19 15 33 24 19 15 23 19 15 23 18 15 22 18 15 14
165 0 0 90-150 65 0.5 0.8 10 32 23 17 14 31 22 17 14 22 17 14 21 17 14 20 16 13 12
175 1 0 90-180 65 0.5 0.8
180 0 0-180 8322 64.0 100.0
Candela Distribution TOTAL LUMINAIRE EFFICIENCY = 58.2%
REPORT NUMBER: KPB175HG3_AN
Lamps: 175 W Metal Halide ED28 Mogul Base with
G3 Globe and 30 Angle Dome Reflector
0.0 45.0 90.0 135.0 180.0 Flux CIE Type Direct
0-deg
90-deg
180-deg L
E
G
E
N
D
0 1632 1632 1632 1632 1632
Plane
Spacing
Criteria 5 1775 1717 1629 1535 1497 156
15 2164 1935 1679 1521 1441 495 0 1.8
25 2297 2040 1812 1593 1441 853 90 1.6 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
35 2825 2193 1990 1459 911 1130 180 1.2 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
45 2160 1912 1574 618 383 1057 RC 80 70 50 30 10 0
55 2600 2181 1463 310 111 1170 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
65 2569 2117 603 52 0 1047 0 69 69 69 69 68 68 68 68 64 64 64 61 61 61 58 58 58 56
75 2489 1874 305 1 0 858 1 62 58 55 52 60 56 53 51 53 51 49 50 48 47 48 46 45 43
85 2234 766 89 1 2 555 2 55 49 45 41 53 48 44 40 45 42 39 43 40 37 41 38 36 34
90 1366 503 15 4 4 ZONAL LUMEN SUMMARY 3 50 43 37 33 48 42 36 32 39 35 31 37 34 31 35 32 30 28
95 600 349 2 6 6 190 ZONE LUMENS %LAMP %FIXT 4 45 37 32 27 44 36 31 27 35 30 26 33 29 26 31 28 25 23
105 299 128 4 10 10 78 0- 30 1505 11.6 19.7 5 41 33 27 23 40 32 27 23 31 26 22 29 25 22 28 24 21 20
115 88 2 4 74 70 44 0- 40 2635 20.3 34.5 6 38 30 24 20 37 29 24 20 28 23 19 26 22 19 25 21 19 17
125 0 3 6 6 4 4 0- 60 4862 37.4 63.6 7 35 27 21 17 34 26 21 17 25 20 17 24 20 17 23 19 16 15
135 2 3 6 5 6 4 0- 90 7321 56.3 95.8 8 33 24 19 15 32 24 19 15 23 18 15 22 18 15 21 17 14 13
145 0 3 3 3 2 3 90-120 312 2.4 4.1 9 31 22 17 14 30 22 17 14 21 16 13 20 16 13 19 16 13 12
155 0 1 4 2 4 1 90-130 316 2.4 4.1 10 29 20 16 12 28 20 15 12 19 15 12 19 15 12 18 14 12 11
165 0 3 5 3 4 1 90-150 322 2.5 4.2
175 0 2 3 2 0 0 90-180 324 2.5 4.2
180 2 2 2 2 2 0-180 7645 58.8 100.0
Mercmaster

III HID 50-250 W


Photmetric Data
For Metal Halide Lamps
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 53
F1-53
F
Degree Candela Lumens TOTAL LUMINAIRE EFFICIENCY = 84.1%
REPORT NUMBER: KPB100LG3
Lamps: 100 W High Pressure Sodium C100S54 ED23 - 1/2
Mogul Base with G3 Globe only
0 269 CIE Type Semi-Direct
5 267 27 Spacing Criteria: 3.1
15 407 117
25 571 267
35 748 442 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
45 451 380 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
55 848 735 RC 80 70 50 30 10 0
65 915 908 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
75 976 1033 0 93 93 93 93 87 87 87 87 76 76 76 66 66 66 57 57 57 53
85 1021 1113 1 79 72 67 62 73 67 62 58 58 54 50 49 46 43 41 39 36 32
90 1027 ZONAL LUMEN SUMMARY 2 69 60 52 46 64 56 49 43 48 42 37 40 36 32 33 30 26 23
95 1019 1109 ZONE LUMENS %LAMP %FIXT. 3 62 51 43 36 57 47 40 34 40 34 29 34 29 24 28 24 20 17
105 953 1002 0-30 410 4.3 5.1 4 56 44 36 29 51 41 33 27 35 28 23 29 24 20 24 19 16 13
115 791 734 0-40 852 9.0 10.7 5 51 39 30 24 47 36 28 22 30 24 19 25 20 16 21 17 13 10
125 54 103 0-60 1967 20.7 24.6 6 47 34 26 20 43 32 24 19 27 21 16 23 17 13 19 14 11 8
135 13 9 0-90 5021 52.9 62.9 7 43 31 23 17 40 28 21 16 24 18 14 20 15 13 17 13 9 7
145 13 8 90-120 2845 29.9 35.6 8 40 28 20 15 37 26 19 14 22 16 12 19 14 10 15 11 8 6
155 4 2 90-130 2948 31.0 36.9 9 37 25 18 13 34 23 17 12 20 14 10 17 12 9 14 10 7 5
165 0 0 90-150 2965 31.2 37.1 10 34 23 16 11 32 21 15 11 18 13 9 16 11 8 13 9 6 5
175 0 0 90-180 2967 31.2 37.1
180 1 0-180 7988 84.1 100.0
Degree Candela Lumens TOTAL LUMINAIRE EFFICIENCY = 72.9%
REPORT NUMBER: KPB100LG3_ST
Lamps: 100 W High Pressure Sodium C100S54 ED23 - 1/2
Mogul Base with G3 Globe and Standard Dome Reflector
0 1466 CIE Type Direct
5 1473 142 Spacing Criteria: 1.6
15 1607 456
25 1675 775
35 1757 1071 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
45 1316 1047 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
55 1502 1316 RC 80 70 50 30 10 0
65 1377 1362 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
75 465 589 0 87 87 87 87 85 85 85 85 81 81 81 77 77 77 74 74 74 72
85 92 111 1 78 74 71 68 76 73 70 67 70 67 65 67 64 62 64 62 60 59
90 16 ZONAL LUMEN SUMMARY 2 70 64 58 53 68 62 57 53 59 55 51 57 53 50 54 52 49 47
95 3 5 ZONE LUMENS %LAMP %FIXT. 3 63 55 48 43 61 54 47 43 51 46 42 49 45 41 47 43 40 38
105 6 6 0-30 1373 14.5 19.8 4 57 48 41 35 55 47 40 35 45 39 34 43 38 34 41 37 33 32
115 40 33 0-40 2445 25.7 35.3 5 52 42 35 30 51 41 34 29 39 34 29 38 33 29 36 32 28 26
125 5 8 0-60 4807 50.6 69.4 6 48 37 30 25 46 37 30 25 35 29 25 34 29 25 33 28 24 23
135 3 2 0-90 6869 72.3 99.2 7 44 34 27 22 43 33 26 22 32 26 22 31 25 21 29 25 21 20
145 3 1 90-120 45 0.5 0.6 8 41 30 24 19 40 30 24 19 29 23 19 28 23 19 27 22 19 17
155 2 1 90-130 53 0.6 0.8 9 38 23 21 17 37 27 21 17 26 21 17 25 20 17 25 20 17 15
165 0 1 90-150 56 0.6 0.8 10 36 25 19 15 35 25 19 15 24 19 15 23 19 15 23 18 15 14
175 1 0 90-180 58 0.6 0.8
180 1 0-180 6927 72.9 100.0
Candela Distribution TOTAL LUMINAIRE EFFICIENCY = 65.0%
REPORT NUMBER: KPB100LG3_AN
Lamps: 100 W High Pressure Sodium C100S54 ED23 - 1/2
Mogul Base with G3 Globe and 30 Angle Reflector
0.0 45.0 90.0 135.0 180.0 Flux CIE Type Direct
0-deg
90-deg
180-deg L
E
G
E
N
D
0 1270 1270 1270 1270 1270
Plane
Spacing
Criteria 5 1317 1302 1271 1227 1211 122
15 1554 1471 1384 1341 1298 398 0 1.9
25 1779 1680 1528 1353 1246 694 90 1.7 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
35 1923 1830 1593 1256 1020 917 180 1.3 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
45 1715 1564 1163 599 361 848 RC 80 70 50 30 10 0
55 1981 1862 1100 287 122 953 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
65 1923 1751 869 104 0 869 0 77 77 77 77 75 75 75 75 71 71 71 67 67 67 64 64 64 62
75 1879 1272 298 9 0 711 1 68 64 61 57 66 62 59 56 59 56 54 56 54 52 53 51 50 48
85 1371 828 140 1 0 424 2 61 55 49 45 59 53 48 44 50 46 43 48 44 41 45 42 40 38
90 680 422 89 2 1 ZONAL LUMEN SUMMARY 3 55 47 41 36 53 46 40 36 44 39 35 41 37 34 39 36 33 31
95 416 259 47 4 4 144 ZONE LUMENS %LAMP %FIXT 4 50 41 35 30 48 40 34 30 38 33 29 36 32 28 35 31 28 26
105 191 93 4 7 6 59 0-30 1213 12.8 19.7 5 46 37 30 25 44 36 30 25 34 29 25 32 28 24 31 27 24 22
115 40 18 51 54 92 31 0-40 2131 22.4 34.5 6 42 33 26 22 41 32 26 22 30 25 21 29 24 21 28 24 20 19
125 1 3 3 3 1 2 0-60 3932 41.4 63.7 7 39 30 23 19 38 29 23 19 28 22 19 26 22 18 25 21 18 17
135 1 2 3 2 1 1 0-90 5936 62.5 96.1 8 36 27 21 17 35 26 21 17 25 20 16 24 20 16 23 19 16 15
145 0 1 2 0 0 1 90-120 234 2.5 3.8 9 34 25 19 15 33 24 19 15 23 18 15 22 18 14 21 17 14 13
155 0 1 2 1 0 1 90-130 236 2.5 3.8 10 32 23 17 14 31 22 17 13 21 17 13 20 16 13 20 16 13 12
165 0 1 1 1 0 0 90-150 238 2.5 3.9
175 2 2 2 1 0 0 90-180 239 2.5 3.9
180 2 2 2 2 2 0-180 6175 65.0 100.0
Mercmaster

III HID 50-250 W


Photmetric Data
For 100-Watt High Pressure Sodium Lamps
Effective August, 2008
Copyright 2008
PAGE 54
800-621-1506
www.appletonelec.com

F1-54
F
Degree Candela Lumens TOTAL LUMINAIRE EFFICIENCY = 81.1%
REPORT NUMBER: KPB150LG3
Lamps: 150 W High Pressure Sodium C100S54 ED23 - 1/2 Mogul
Base with G3 Globe only
0 488 CIE Type Semi-Direct
5 459 46 Spacing Criteria: 3.0
15 703 202
25 938 442
35 1107 672 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
45 892 710 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
55 1420 1253 RC 80 70 50 30 10 0
65 1542 1529 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
75 1629 1723 0 90 90 90 90 84 84 84 84 74 74 74 65 65 65 56 56 56 53
85 1675 1824 1 76 70 65 60 71 65 60 56 56 53 49 48 45 42 41 38 36 32
90 1665 ZONAL LUMEN SUMMARY 2 67 58 51 44 62 54 47 42 46 41 36 39 35 31 33 29 26 23
95 1643 1788 ZONE LUMENS %LAMP %FIXT. 3 60 49 41 34 55 46 38 32 39 33 28 33 28 24 27 23 20 17
105 1515 1599 0-30 689 4.3 5.3 4 54 43 34 29 50 40 32 26 34 27 22 28 23 19 23 19 16 13
115 1072 1042 0-40 1361 8.5 10.5 5 49 37 29 23 45 35 27 21 30 23 18 25 20 16 21 16 13 10
125 51 115 0-60 3324 20.8 25.6 6 45 33 25 19 42 31 23 18 26 20 15 22 17 13 18 14 11 8
135 20 16 0-90 8400 52.5 64.7 7 41 30 22 16 38 27 20 15 24 18 13 20 15 11 16 12 9 7
145 19 12 90-120 4429 27.7 34.1 8 38 27 19 14 35 25 18 13 21 16 11 18 13 10 15 11 8 6
155 6 4 90-130 4544 28.4 35.0 9 36 24 17 12 33 23 16 12 19 14 10 17 12 8 14 10 7 5
165 1 0 90-150 4572 28.6 35.2 10 33 22 15 11 31 21 14 10 18 12 9 15 11 7 13 9 6 4
175 0 0 90-180 4576 28.6 35.3
180 2 0-180 12976 81.1 100.0
Degree Candela Lumens TOTAL LUMINAIRE EFFICIENCY = 69.6%
REPORT NUMBER: KPB150LG3_ST
Lamps: 150 W High Pressure Sodium C100S54 ED23 - 1/2 Mogul
Base with G3 Globe and Standard Dome Reflector
0 2403 CIE Type Direct
5 2391 230 Spacing Criteria: 1.6
15 2624 744
25 2678 1247
35 2705 1673 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
45 2250 1754 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
55 2444 2161 RC 80 70 50 30 10 0
65 2246 2192 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
75 655 851 0 83 83 83 83 81 81 81 81 77 77 77 74 74 74 70 70 70 69
85 147 174 1 75 71 68 65 73 70 67 64 66 64 62 64 62 60 61 59 58 56
90 26 ZONAL LUMEN SUMMARY 2 67 61 56 51 65 60 55 51 57 53 49 54 51 48 52 49 47 45
95 6 8 ZONE LUMENS %LAMP %FIXT. 3 61 52 46 41 59 51 46 41 49 44 40 47 43 39 45 41 38 37
105 11 13 0-30 2221 13.9 19.9 4 55 46 39 34 53 45 38 34 43 37 33 41 36 33 39 35 32 30
115 73 71 0-40 3895 24.3 35.0 5 50 40 33 28 48 39 33 28 38 32 28 36 31 27 35 31 27 25
125 7 12 0-60 7809 48.8 70.1 6 46 36 29 24 44 35 29 24 34 28 24 32 27 24 31 27 23 22
135 6 3 0-90 11027 68.9 99.0 7 42 32 26 21 41 32 25 21 30 25 21 29 24 20 28 24 20 19
145 4 2 90-120 92 0.6 0.8 8 39 29 23 18 38 29 23 18 28 22 18 27 22 18 26 22 18 16
155 4 2 90-130 104 0.6 0.9 9 36 27 20 16 35 26 20 16 25 20 16 24 20 16 24 19 16 15
165 2 1 90-150 109 0.7 1.0 10 34 24 19 15 33 24 18 15 23 18 14 22 18 14 22 17 14 13
175 2 0 90-180 112 0.7 1.0
180 1 0-180 11139 69.6 100.0
Candela Distribution TOTAL LUMINAIRE EFFICIENCY = 61.0%
REPORT NUMBER: KPB150LG3_AN
Lamps: 150 W High Pressure Sodium C100S54 ED23 - 1/2 Mogul
Base with G3 Globe and 30 Angle Reflector
0.0 45.0 90.0 135.0180.0 Flux CIE Type Direct
0-deg
90-deg
180-deg L
E
G
E
N
D
0 1964 1964 1964 1964 1964
Plane
Spacing
Criteria 5 2035 2007 1941 1871 1838 187
15 2375 2307 2140 2047 2037 619 0 2.0
25 2755 2587 2288 2095 1853 1081 90 1.7 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
35 2924 2763 2415 1885 1276 1416 180 1.3 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
45 2790 2552 2015 780 518 1368 RC 80 70 50 30 10 0
55 3166 2937 1945 410 157 1520 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
65 3188 2913 777 77 0 1380 0 72 72 72 72 70 70 70 70 66 66 66 63 63 63 60 60 60 58
75 3145 2547 408 1 2 1118 1 64 60 57 54 62 58 55 53 55 53 50 52 50 48 50 48 47 45
85 2533 927 117 0 2 663 2 57 51 46 42 55 50 45 41 47 43 40 45 41 39 42 40 37 36
90 1490 640 14 5 9 ZONAL LUMEN SUMMARY 3 52 44 38 34 50 43 38 33 41 36 33 39 35 32 37 33 31 29
95 765 449 5 8 11 239 ZONE LUMENS %LAMP %FIXT 4 47 39 33 28 45 38 32 28 36 31 27 34 30 26 32 29 26 24
105 380 163 6 11 15 106 0-30 1886 11.8 19.3 5 43 34 28 24 41 33 28 24 32 27 23 30 26 22 29 25 22 21
115 114 4 6 18 63 44 0-40 3302 20.6 33.8 6 39 31 25 20 38 30 24 20 28 24 20 27 23 19 26 22 19 18
125 2 5 7 8 7 5 0-60 6190 38.7 63.5 7 36 28 22 18 35 27 22 18 26 21 17 25 20 17 24 20 17 15
135 2 6 7 8 6 4 0-90 9351 58.4 95.9 8 34 25 20 16 33 24 19 16 23 19 15 22 18 15 22 18 15 14
145 0 2 6 4 2 3 90-120 389 2.4 4.0 9 32 23 18 14 30 22 17 14 21 17 14 21 16 13 20 16 13 12
155 2 4 6 6 4 2 90-130 395 2.5 4.0 10 30 21 16 13 29 21 16 12 20 15 12 19 15 12 18 15 12 11
165 4 3 5 4 2 1 90-150 401 2.5 4.1
175 0 2 3 3 2 0 90-180 404 2.5 4.1
180 2 2 2 2 2 0-180 9754 61.0 100.0
Mercmaster

III HID 50-250 W


Photmetric Data
For 150-Watt High Pressure Sodium Lamps
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 55
F1-55
F
Mercmaster

III 400
Enclosed and Gasketed Fixtures for Hazardous and Wet Locations
High Pressure Sodium, Metal Halide and Pulse Start Metal Halide.
Listed for si mul ta ne ous ex po sure to com bust i ble dusts and flam ma ble gas es or va pors.
Applications
Enclosed and gas ket ed fix tures
suit a ble for use in ma rine and wet
lo ca tions, and in a wide range of
in dus tri al, chem i cal pro cess ing
and oth er ar e as where flam ma ble
gas es and va pors or com bust i ble
dusts are present un der con di tions
de fined by the National Electri-
cal Code as Class I, Div. 2; Class
II, Div. 1 and 2; and Class III. For
Zone 2, the method of protection is
Restricted Breathing.
In ap pli ca tions in volv ing me di um
and high mount ing heights.
In ap pli ca tions where en er gy ef fi-
cient, high lu men out put is re quired.
Suited for use in non-haz ard ous lo ca-
tions where se vere weath er con di tions,
ex ces sive mois ture, dirt, dust, cor ro-
sive at mos phere or high am bi ent tem-
per a tures are en coun tered.
Typical ap pli ca tions in clude pulp
and paper mills, pro cess ing plants,
chem i cal plants, oil re fin er ies, foun-
dries, man u fac tur ing plants, stor age
ar e as, waste and sew age treat ment,
and oth er ar e as where dust, wa ter,
dirt and rough us age are a prob lem.
Features
Superior cor ro sion re sis tance;
cop per-free (less than 4/10 of 1%
cop per) alu mi num mount ing hoods,
bal last housings and guards have a
grey ep oxy pow der coat, elec tro stat-
i cal ly ap plied for com plete and uni-
form pro tec tion.
Choice of light sourc es: high pres-
sure so di um, met al ha lide and pulse
start metal halide.
Six mount ing ar range ments to suit
any light ing lay out: pen dant, ceil ing,
wall brack et, 25(an gle) stan chion,
90(straight) stan chion and cone.
Hinge has high lip for add ed safe-
ty dur ing in stal la tion and ser vic ing.
Hinge and bolt con struc tion as sures
360 com pres sion at all points on
bal last hous ing gas ket for pos i tive
seal ing. Swing away de sign of cap-
tive bolt and nut sim pli fies ser vic ing.
Choice of op ti cal as sem blies: pris-
mat ic globe; en closed re flec tor with
Enclosed Reflector
Prismatic
Glass Globe
12 Glass Refractor
sealed lens; or Type V or Type II
closed pris mat ic glass re frac tor,
with or with out guards.
Wide choice of pho to met ric dis tri bu tions.
All fix tures de signed to per form in a
40 C am bi ent tem per a ture. Select-
ed fix tures are suit a ble for am bi ent
tem per a tures up to 65 C.
Body gaskets and globe gaskets
are high-temperature silicone rub-
ber.
Mogul base porcelain lamp holder
with nickel-plated contacts has 200
C rated welded leads, pre-wired to
the ballast. Assures trouble-free oper-
ation in installations where high ambi-
ent temperatures are encountered.
For electrical protection, a ground
wire is provided on each Merc-
master to bond hood and ballast
housing.
Terminal blocks are provided for
Zone 2 fixtures to facilitate wiring.
Standard dome of 30 an gle re flec-
tors made of fi ber glass re in forced
white poly es ter. Highly re sist ant to
cor ro sive at mos pheres.
Fixture hous ing mount ing hoods
and guards are die cast cop per-
free alu mi num with ep oxy pow der
coat fin ish. All ex posed hard ware is
stain less steel.
A wide range of volt ages avail a ble:
(120 to 480 Volt) 60 Hz.
One-piece bal last hous ing for each
com po nent pro vides even heat dis-
si pa tion for cool er op er a tion and
long er bal last life.
All Mercmaster mount ing hoods
have pro vi sion for easy field in stal-
la tion of fus es in fix tures (see fuse
kit list ings).
Standard Materials
Mounting hoods and bal last bod-
ies: copper-free cast alu mi num (less
than 4/10 of 1% cop per).
Reflectors: fi ber glass-re in forced
white poly es ter.
All hard ware and catch as sem blies:
stain less steel.
Globe: heat- and im pact-re sist ant
in ter nal ly flut ed glass.
Refractors: pris mat ic glass
Effective August, 2008
Copyright 2008
PAGE 56
800-621-1506
www.appletonelec.com

F1-56
F
Ordering Information:
Order using catalog numbering guide below or select catalog number from tables on following pages.
SERIES:
KP - Mercmaster III 400
MOUNTING:
A - Pendant (rigid mounting)
C - Ceiling
CH - Pendant Cone
F - Pendant (flexible mounting)
ST - 90 Stanchion
S - 25 Stanchion
WB - Wall
LAMP TYPE:
H - Metal Halide
L - High Pressure
Sodium
P - Pulse Start
Metal Halide
WATTAGE:
25 - 250W HPS, 250W PSMH
32 - 320W PSMH
35 - 350W PSMH
40 - 400W HPS, MH & PSMH
HUB SIZE:
75 - 3/4 NPT
10 - 1 NPT
125 - 1-1/4 NPT
stanchion
150 - 1-1/2 NPT
stanchion
OPTICAL ASSEMBLY
J2 - NEMA II Refractor
J5 - NEMA V Refractor
R - Enclosed Reflector with
sealed lens
Blank - Globe
GUARD
OPTIONS:
G - Guard
for standard
globes only
VOLTAGE:*
MT - 120/208/240/277 60 Hz
48 - 480 60 Hz
OPTIONS:
E - Emergency
Quartz
F - Fuse Kit
(specify voltage)
S - Smart Starter
PC12 - Photocontrol 120 V
PC20 - Photocontrol 208 V
PC24 - Photocontrol 240 V
PC27 - Photocontrol 277 V
NO DESIGNATION is required for fixtures with standard type globe.
NO DESIGNATION is required for fixtures without guards guards for refractors or enclosed reflector must be ordered separately; see accessories page.
Refer to Mounting Hoods and Ballast page for available Voltage Configuration.
*Other voltages available. Consult factory.
CATALOG NUMBERING GUIDE FOR MERCMASTER III 400 LUMINAIRES
KP A L 40 10 J5 G MT E
Mercmaster

III 400
Enclosed and Gasketed Fixtures for Hazardous and Wet Locations
High Pressure Sodium, Metal Halide and Pulse Start Metal Halide.
Listed for si mul ta ne ous ex po sure to com bust i ble dusts and flam ma ble gas es or va pors.
Enclosed re flec tor: etched Alzak
alu mi num with sealed, tem pered
heat- and im pact-re sist ant lens.
Guards: stain less steel
Options
AEx nR fixtures are available with a
Class I, Zone 2 rating. Add suffix -Z2.
Quartz Auxiliary comes to full bright-
ness im me di ate ly and re mains lit
un til the HID lamp at tains 60-70% of
full il lu mi na tion. Quartz Auxiliary sup-
plied with re lay switch and sock et to
ac cept 120V quartz dou ble-con tact
bay o net base lamp (not in clud ed).
(Not suit a ble for haz ard ous lo ca-
tions.) Add suf fix -E.
Photocontrol details on F1-136.
Smart Starter (for HPS fixtures
only) incorporates a 1-1/2-minute
timer and performs as a conven-
tional starter to normally start lamp.
Removes itself from circuit if lamp
burns out or is removed from socket.
Eliminates starter failures caused by
prolonged operation with cycling or
failing lamps and simplifies finding
their location, which reduces mainte-
nance and repair costs. Available for
all HPS fixtures. Add suffix -S.
Compliances
UL Listed, Marine Type Electric Fix-
tures Outside Type (Salt Water)
UL 1598A, UL 844
UL 60079-15
Class I, Div. 2, Groups A,B,C,D
Class I, Zone 2, AEx nR IIC
Class II, Div. 1 and 2, Groups E,F,G
Class III
NEMA 4X; IP66
Simultaneous Exposure
Class I, Div. 2; Class II, Div. 1
* Compliance data varies for specific fixtures. Con-
sult Appleton regarding suitability of specific fix-
tures for a particular application.
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 57
F1-57
F
High Temperature Sockets
Mogul base high-temperature
porcelain sockets.
Aluminum Inner Reflector
Solid aluminum inner reflector improves
photometric efficiency.
Stainless Steel
Latch Assembly
Captive, stainless
steel latch assembly
bolt and nut closes
securely, resists
attack of corro-
sive atmospheres.
Swing-away design
simplifies servicing.
Fuses
Two screws secure fuse kit to
mounting boss in any Mercmaster
mounting hood. Fuse included.
Epoxy Powder Coat Finish
Ballast housing, hoods and guards are
copper-free aluminum with baked epoxy
corrosion-resistant finish.
Stainless Steel Inserts
Ballast bodies have stainless steel
threaded inserts to receive stainless
steel screws for reflectors and guard.
Prevents freezing, allowing guards
and reflectors to be easily removed and
replaced at any time, without damage
to the housing.
Cooler Operating Cone Hood
Larger sloped surface sheds dusts, dirt
and combustible fibers providing better
heat dissipation.
Electrical Protection
Ground wire provided to bond
mounting hood to ballast housing.
Photocell
Installs through knock-out in mounting
hoods except cone and ceiling mount.
Provides continuous on-off dusk-to-
dawn control.
Vented Reflectors
Reflectors are thick, tough fiberglass-
reinforced white polyester, vented for
cooler operation. Quickly attaches with
furnished stainless steel screws.
Hood/Ballast Gasket
Silicone rubber gasket seals out
moisture, dirt and dust. Stays flexible,
withstands high temperatures. Closure
design assures uniform gasket
compression.
Safety High Hinge
Extra-high hinge
provides additional
protection against
accidental ballast
housing disen-
gagement during
installation or
maintenance.
Prismatic Glass Globes, Refractors
and Enclosed Reflector
Heat-resistant globes, refractors and
enclosed reflector thread into ballast
housing and seal against a high-
temperature silicone rubber gasket.
Mercmaster

III 400
Enclosed and Gasketed Fixtures for Hazardous and Wet Locations
Terminal Blocks (Zone 2)
A seven-point terminal block is provided
to facilitate wiring. Terminal block
accommodates wire size ranging from
#8 to #24 AWG.
Effective August, 2008
Copyright 2008
PAGE 58
800-621-1506
www.appletonelec.com

F1-58
F
Mercmaster

III 400
Thermal Performance: Class I, Div. 2; Class II, Div. 1; and Simultaneous
Exposure to hazardous conditions on both classifications
Temperature identification numbers of Mercmaster III 400 Fixtures
* T numbers are for Groups E and F only.
** Use 90 C rated supply wire.
T Numbers Represent the Maximum Lamp Temperature for Class I, Div. 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Div. 1 Locations
T
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp
Range
(C)
351-450 326-350 301-325 281-300 261-280 231-260 216-230 201-215 181-200 166-180 161-165 136-160 121-135 101-120 86-100 85
Lamp
Ambient
Temp
(C)**
Class I, Div. 2
Class II, Div. 1
Groups E, F and G
Simultaneous Exposure Class I, Div. 2 /
Class II, Div. 1
Watts Type Globe
Globe &
Reflector Refractor
Enclosed
Reflector Globe
Globe &
Reflector Refractor
Enclosed
Reflector Globe
Globe &
Reflector Refractor
Enclosed
Reflector
40 T2 T2 T2 T2 T3B T3B T4 T4A 325 325 325 325
250 HPS 55 325 325 T2 T2 T3B T4A T1 325
65 T2 T2 T3B T4 T1 350
400 HPS 40 350 T1 T1 350 T3* T3* T3C T3C T1 T1 T1 350
400 MH 40 T2 T2 T2A T2A T3A* T4 325 T2A
40 T2B T2B T2B T2C T3* T3* T4 T4A
250 PSMH 55 T2A T2A T2B T2C
65 T2C
320 PSMH 40 T2B T2B T2B T2B T3C T3C
55 T2A T2A T2A T2B
350 PSMH 40 T2B T2B T2B T2B T3C T3C
55 T2A T2A T2A T2B
400 PSMH 40 T2A T2A T2B T2B T3C T3C
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 59
F1-59
F
Mercmaster

III 400
Thermal Performance: Class I, Zone 2, AEx nR IIC IP66, NEMA 4X
Temperature Identification numbers of Mercmaster III Fixtures
T Numbers represent the maximum surface temperature for luminaries with AEx nR rating:
To comply with AEx nR Requirements, all wiring entries must be sealed.
* Use 90 C rated supply wire.
Lamp
Ambient
Temp.*
C
Class 1, Zone 2 AEx nR
Watts Type Globe
Globe &
Reflector
Enclosed
Reflector
HPS 40 T4 T4 T5
250 HPS 55 T3 T3 T3
HPS 65 T3
400 HPS 40 T4 T4 T5
PSMH 40 T3 T3 T3
250 PSMH 55 T3 T3 T3
PSMH 65 T3
320 PSMH 40 T4 T4 T4
PSMH 55 T3 T3 T4
350 PSMH 40 T4 T4 T4
PSMH 55 T3 T3 T4
400 PSMH 40 T3 T3 T3
400 MH 40 T3 T3 T3
T
Number
T1 T2 T3 T4 T5 T6
Temp.
Range
(C)
301-450 201-300 136-200 101-135 86-100 85
Effective August, 2008
Copyright 2008
PAGE 60
800-621-1506
www.appletonelec.com

F1-60
F
Mercmaster

III 400
Enclosed and Gasketed Fixtures for Hazardous and Wet Locations
250 W and 400 W High Pressure Sodium; 400 W Metal Halide; and
250 W, 320 W, 350 W and 400 W Pulse Start Metal Halide.
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
UL Listed
CSA Certified
Simultaneous Exposure
Class I, Div. 2; Class II, Div. 1
Class I, Div. 2; Groups A,B,C,D
Class I, Zone 2, AEx nR IIC
Class II, Div. 1 and 2; Groups E,F,G
Class III
UL 1598A, UL 844 Marine Type Electric
Fixtures Outside Type (Salt-water)
NEMA 4X; 1P66
Shown with Globe
Shown with Refractor
Type
Mounting
Hub Size
(Inches)
Catalog Numbers
Lamp
Type
Lamp
Watts With Globe
With Type V 12
Refractor
With Enclosed
Reflector
Pendant HPS 250 3/4 KPAL2575 KPAL2575J5 KPAL2575R
One Hub,
Rigid Mounting
1 KPAL2510 KPAL2510J5 KPAL2510R
HPS 400 3/4 KPAL4075 KPAL4075J5 KPAL4075R
1 KPAL4010 KPAL4010J5 KPAL4010R
MH 400 3/4 KPAH4075 KPAH4075J5 KPAH4075R
1 KPAH4010 KPAH4010J5 KPAH4010R
PSMH 250 3/4 KPAP2575 KPAP2575J5 KPAP2575R
1 KPAP2510 KPAP2510J5 KPAP2510R
PSMH 320 3/4 KPAP3275 KPAP3275J5 KPAP3275R
1 KPAP3210 KPAP3210J5 KPAP3210R
PSMH 350 3/4 KPAP3575 KPAP3575J5 KPAP3575R
1 KPAP3510 KPAP3510J5 KPAP3510R
PSMH 400 3/4 KPAP4075 KPAP4075J5 KPAP4075R
1 KPAP4010 KPAP4010J5 KPAP4010R
Pendant Cone HPS 250 3/4 KPCHL2575 KPCHL2575J5 KPCHL2575R
One Hub,
Rigid Mounting
1 KPCHL2510 KPCHL2510J5 KPCHL2510R
HPS 400 3/4 KPCHL4075 KPCHL4075J5 KPCHL4075R
1 KPCHL4010 KPCHL4010J5 KPCHL4010R
MH 400 3/4 KPCHH4075 KPCHH4075J5 KPCHH4075R
1 KPCHH4010 KPCHH4010J5 KPCHH4010R
PSMH 250 3/4 KPCHP2575 KPCHP2575J5 KPCHP2575R
1 KPCHP2510 KPCHP2510J5 KPCHP2510R
PSMH 320 3/4 KPCHP3275 KPCHP3275J5 KPCHP3275R
1 KPCHP3210 KPCHP3210J5 KPCHP3210R
PSMH 350 3/4 KPCHP3575 KPCHP3575J5 KPCHP3575R
1 KPCHP3510 KPCHP3510J5 KPCHP3510R
PSMH 400 3/4 KPCHP4075 KPCHP4075J5 KPCHP4075R
1 KPCHP4010 KPCHP4010J5 KPCHP4010R
For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
To order xture with NEMA Type II refractor, change nal digit J5 in catalog number to J2.
Add the following voltage and frequency designations before Z2 or ZB sufx:
Sufx Voltage Frequency Notes
MT 120/208/240/277 60 Hz All
5MT 120/208/240/277/480 60 Hz 250 W and 400 W HPS; 400 W MH; and 250 W, 320 W, 350 W and 400 W PSMH
AM 127/220 60 Hz 400 W HPS; 400 W MH
AK 220/240 60 Hz 250 W HPS
48 480 60 Hz All
XQ 120/230 50 Hz 250 W and 400 W HPS; 250 W and 400 W MH; and 200 W, 250 W, 320 W, 350 W and 400 W PSMH
(For 250 W MH and 200 W PSMH 50 Hz xtures, see pages F1-35 to F1-38.)
Add Z2 sufx for factory sealed non-sparking/restricted breathing protection (Aex nA nR). Add ZB sufx for factory sealed restricted breathing protection (Aex nR).
For xtures with guards, add sufx G before adding voltage sufx.
Guards for xtures with refractors and enclosed reectors must be ordered separately. See following pages for accessory ordering information.
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 61
F1-61
F
Shown with Enclosed Reflector
Shown with 12 Glass Refractor
Hub Size
(In.)
Catalog Numbers
Type
Mounting
Lamp
Type
Lamp
Watts With Globe
With Type V 12
Refractor
With Enclosed
Reflector
Ceiling HPS 250 3/4 KPCL2575 KPCL2575J5 KPCL2575R
Five Hubs,
Four Close-Up
Plugs
1 KPCL2510 KPCL2510J5 KPCL2510R
HPS 400 3/4 KPCL4075 KPCL4075J5 KPCL4075R
1 KPCL4010 KPCL4010J5 KPCL4010R
MH 400 3/4 KPCH4075 KPCH4075J5 KPCH4075R
1 KPCH4010 KPCH4010J5 KPCH4010R
PSMH 250 3/4 KPCP2575 KPCP2575J5 KPCP2575R
1 KPCP2510 KPCP2510J5 KPCP2510R
PSMH 320 3/4 KPCP3275 KPCP3275J5 KPCP3275R
1 KPCP3210 KPCP3210J5 KPCP3210R
PSMH 350 3/4 KPCP3575 KPCP3575J5 KPCP3575R
1 KPCP3510 KPCP3510J5 KPCP3510R
PSMH 400 3/4 KPCP4075 KPCP4075J5 KPCP4075R
1 KPCP4010 KPCP4010J5 KPCP4010R
Wall HPS 250 3/4 KPWBL2575 KPWBL2575J5 KPWBL2575R
Five Hubs,
Four Close-Up
Plugs

1 KPWBL2510 KPWBL2510J5 KPWBL2510R
HPS 400 3/4 KPWBL4075 KPWBL4075J5 KPWBL4075R
1 KPWBL4010 KPWBL4010J5 KPWBL4010R
MH 400 3/4 KPWBH4075 KPWBH4075J5 KPWBH4075R
1 KPWBH4010 KPWBH4010J5 KPWBH4010R
PSMH 250 3/4 KPWBP2575 KPWBP2575J5 KPWBP2575R
1 KPWBP2510 KPWBP2510J5 KPWBP2510R
PSMH 320 3/4 KPWBP3275 KPWBP3275J5 KPWBP3275R
1 KPWBP3210 KPWBP3210J5 KPWBP3210R
PSMH 350 3/4 KPWBP3575 KPWBP3575J5 KPWBP3575R
1 KPWBP3510 KPWBP3510J5 KPWBP3510R
PSMH 400 3/4 KPWBP4075 KPWBP4075J5 KPWBP4075R
1 KPWBP4010 KPWBP4010J5 KPWBP4010R
Mercmaster

III 400
Enclosed and Gasketed Fixtures for Hazardous and Wet Locations
250 W and 400 W High Pressure Sodium; 400 W Metal Halide; and
250 W, 320 W, 350 W and 400 W Pulse Start Metal Halide.
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
UL Listed
CSA Certified
Simultaneous Exposure
Class I, Div. 2; Class II, Div. 1
Class I, Div. 2; Groups A,B,C,D
Class I, Zone 2, AEx nR IIC
Class II, Div. 1 and 2; Groups E,F,G
Class III
UL 1598A, UL 844 Marine Type Electric
Fixtures Outside Type (Salt-water)
NEMA 4X; 1P66
To order xture with NEMA Type II refractor, change nal digit J5 in catalog number to J2.
Add the following voltage and frequency designations before Z2 or ZB sufx:
Sufx Voltage Frequency Notes
MT 120/208/240/277 60 Hz All
5MT 120/208/240/277/480 60 Hz 250 W and 400 W HPS; 400 W MH; and 250 W, 320 W, 350 W and 400 W PSMH
AM 127/220 60 Hz 400 W HPS; 400 W MH
AK 220/240 60 Hz 250 W HPS
48 480 60 Hz All
XQ 120/230 50 Hz 250 W and 400 W HPS; 250 W and 400 W MH; and 200 W, 250 W, 320 W, 350 W and 400 W PSMH
(For 250 W MH and 200 W PSMH 50 Hz xtures, see pages F1-35 to F1-38.)
Add Z2 sufx for factory sealed non-sparking/restricted breathing protection (Aex nA nR). Add ZB sufx for factory sealed restricted breathing protection (Aex nR).
For xtures with guards, add sufx G before adding voltage sufx.
Guards for xtures with refractors and enclosed reectors must be ordered separately. See following pages for accessory ordering information.
Effective August, 2008
Copyright 2008
PAGE 62
800-621-1506
www.appletonelec.com

F1-62
F
Hub Size
(In.)
Catalog Numbers
Type
Mounting
Lamp
Type
Lamp
Watts With Globe
With Type V 12
Refractor
With Enclosed
Reflector
25 Stanchion HPS 250 1-1/4 KPSL25125 KPSL25125J5 KPSL25125R
One Hub 1-1/2 KPSL25150 KPSL25150J5 KPSL25150R
HPS 400 1-1/4 KPSL40125 KPSL40125J5 KPSL40125R
1-1/2 KPSL40150 KPSL40150J5 KPSL40150R
MH 400 1-1/4 KPSH40125 KPSH40125J5 KPSH40125R
1-1/2 KPSH40150 KPSH40150J5 KPSH40150R
PSMH 250 1-1/4 KPSP25125 KPSP25125J5 KPSP25125R
1-1/2 KPSP25150 KPSP25150J5 KPSP25150R
PSMH 320 1-1/4 KPSP32125 KPSP32125J5 KPSP32125R
1-1/2 KPSP32150 KPSP32150J5 KPSP32150R
PSMH 350 1-1/4 KPSP35125 KPSP35125J5 KPSP35125R
1-1/2 KPSP35150 KPSP35150J5 KPSP35150R
PSMH 400 1-1/4 KPSP40125 KPSP40125J5 KPSP40125R
1-1/2 KPSP40150 KPSP40150J5 KPSP40150R
90 Stanchion HPS 250 1-1/4 KPSTL25125 KPSTL25125J5 KPSTL25125R
One Hub 1-1/2 KPSTL25150 KPSTL25150J5 KPSTL25150R
HPS 400 1-1/4 KPSTL40125 KPSTL40125J5 KPSTL40125R
1-1/2 KPSTL40150 KPSTL40150J5 KPSTL40150R
MH 400 1-1/4 KPSTH40125 KPSTH40125J5 KPSTH40125R
1-1/2 KPSTH40150 KPSTH40150J5 KPSTH40150R
PSMH 250 1-1/4 KPSTP25125 KPSTP25125J5 KPSTP25125R
1-1/2 KPSTP25150 KPSTP25150J5 KPSTP25150R
PSMH 320 1-1/4 KPSTP32125 KPSTP32125J5 KPSTP32125R
1-1/2 KPSTP32150 KPSTP32150J5 KPSTP32150R
PSMH 350 1-1/4 KPSTP35125 KPSTP35125J5 KPSTP35125R
1-1/2 KPSTP35150 KPSTP35150J5 KPSTP35150R
PSMH 400 1-1/4 KPSTP40125 KPSTP40125J5 KPSTP40125R
1-1/2 KPSTP40150 KPSTP40150J5 KPSTP40150R
Mercmaster

III 400
Enclosed and Gasketed Fixtures for Hazardous and Wet Locations
250 W and 400 W High Pressure Sodium; 400 W Metal Halide; and
250 W, 320 W, 350 W and 400 W Pulse Start Metal Halide.
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
UL Listed
CSA Certified
Simultaneous Exposure
Class I, Div. 2; Class II, Div. 1
Class I, Div. 2; Groups A,B,C,D
Class I, Zone 2, AEx nR IIC
Class II, Div. 1 and 2; Groups E,F,G
Class III
UL 1598A, UL 844 Marine Type Electric
Fixtures Outside Type (Salt-water)
NEMA 4X; 1P66
Shown with Prismatic Glass Globe
and Optional Guard
Shown with Prismatic Glass Globe
and Optional Guard
To order xture with NEMA Type II refractor, change nal digit J5 in catalog number to J2.
Add the following voltage and frequency designations before Z2 or ZB sufx:
Sufx Voltage Frequency Notes
MT 120/208/240/277 60 Hz All
5MT 120/208/240/277/480 60 Hz 250 W and 400 W HPS; 400 W MH; and 250 W, 320 W, 350 W and 400 W PSMH
AM 127/220 60 Hz 400 W HPS; 400 W MH
AK 220/240 60 Hz 250 W HPS
48 480 60 Hz All
XQ 120/230 50 Hz 250 W and 400 W HPS; 250 W and 400 W MH; and 200 W, 250 W, 320 W, 350 W and 400 W PSMH
(For 250 W MH and 200 W PSMH 50 Hz xtures, see pages F1-35 to F1-38.)
Add Z2 sufx for factory sealed non-sparking/restricted breathing protection (Aex nA nR). Add ZB sufx for factory sealed restricted breathing protection (Aex nR).
For xtures with guards, add sufx G before adding voltage sufx.
Guards for xtures with refractors and enclosed reectors must be ordered separately. See following pages for accessory ordering information.
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 63
F1-63
F
Hazardous Location Photocontrols
Factory-Sealed
Applications
Encapsulated photocontrol provides
automatic dusk-to-dawn lighting
control in Class I, Div. 2 locations.
Typical applications include walk-
ways, security areas and any other
outdoor lighting application.
For use with Mercmaster III Low
Profile, Mercmaster III, and Merc-
master III 400 Series Luminaires.
For remote mounting in FS Boxes.
Features
Factory-sealed design eliminates the
need for an explosionproof enclosure.
Can be easily installed in the field.
Solid state design for performance
and reliability.
Available for 120, 208, 240, or 277
volts.
35-400 W H.I.D. incandescent or
fluorescent, 50/60 HZ.
1000 V.A. Voltage/Ampere
Minimum time delay: 15 seconds to
eliminate nuisiance tripping.
Turns fixture on at 3 footcandles, off
at 8 footcandles.
Provided with (3) 18AWG stranded
leads 6 in length.
Will fit through standard 1/2
knockout.
Materials
Encapsulated with epoxy sealing
compound.
FS Cover: aluminum
Compliances
Class I, Div. 2, Groups A,B,C,D
UL Standards: 1604 Hazardous
(Classified) Locations
NEMA 4X
PCD2 Series Hazardous Location Photocontrol
For use in Class I, Div. 2, Groups A,B,C,D locations.
Class I, Div. 2,
Groups A,B,C,D
Maintains Class I, Div. 2
rating for Mercmaster III
Low Profile, Mercmaster III,
and Mercmaster III 400
Series Luminaires
NEMA 4X
Ordering Information
1.13
(2.87 cm)
0.69
(1.75 cm)
1.94
(4.92 cm)
1.19
(3.02 cm)
1.375
(3.49cm)
2.56
(6.50 cm)
Factory-installed Photocontrol
Suffix Designation* Voltage Range
PC120 120 V, 50/60 Hz
PC208 208 V, 50/60 Hz
PC240 240 V, 50/60 Hz
Mercmaster III wall mounting hood with
photocontrol installed shown PC277 277 V, 50/60 Hz
Add to fixture catalog after voltage; i.e.: KPWBL1075MTPC12.
Photocontrol in FS cover for use with FS/FD box (Section B)
Catalog Number Voltage Range
FSKA-PC120D2 120V, 50/60 Hz
FSKA-PC247D2 208-277V, 50/60 Hz
Supplied with two stainless steel screws.
For neoprene gasket, order catalog number FS-GKR-1N.
Photocontrol for field installation
Catalog Number Max. Current Voltage Range
PC120D2 8.3 A 120 V, 50/60 Hz
PC247D2 3.5 A 208-277 V, 50/60 Hz
Dimensions
Effective August, 2008
Copyright 2008
PAGE 64
800-621-1506
www.appletonelec.com

F1-64
F
Mercmaster

III 400
Mounting Hoods and Ballasts
Hoods and Ballast Housings are Copper-Free Cast Aluminum (less than 4/10 of 1%).
Mounting Hoods
Description Hub Size (Inches) Catalog Number
Pendant
One Hub,
Rigid Mounting
3/4 KPA-75
1 KPA-100
Pendant (Flexible)
One Hub,
Flexible Mounting
3/4 KPAF-75
1 KPAF-100
Pendant Cone
One Hub,
Rigid Mounting
3/4 KPCH-75
1 KPCH-100
Ceiling
Five Hubs,
Four Close-Up Plugs
3/4 KPC-75
1 KPC-100
Wall
Five Hubs,
Four Close-Up Plugs
3/4 KPWB-75
1 KPWB-100
25 Stanchion
One Hub 1-1/4 KPS-125
1-1/2 KPS-150
90 Stanchion
One Hub 1-1/4 KPST-125
1-1/2 KPST-150
Add -S after voltage designation for ballast body with Smart Starter (HPS only).

Add -E after voltage designation for ballast body with provision for Quartz Emergency Light (not suitable for hazardous location).
* Add -Z2 after voltage designation for restricted breathing protection (AEx nR).
Ballast Bodies
Lamp Watts
Catalog
Numbers
Voltage Designation
Type MT 5MT AM AK 48 XQ
High Pressure Sodium 250 KPB250L X X X X X
Constant Wattage 400 KPB400L X X X X X
(Min. P.F. 90%)
Metal Halide 400 KPB400H X X X X X
Constant Wattage
(Min. P.F. 90%)
Pulse Start Metal Halide 250 KPB250P X X X X
Super Constant Wattage 320 KPB320P X X X X
(Min. P.F. 90%) 350 KPB350P X X X X
400 KPB400P X X X X
Voltage: -MT 120/208/240/277 V, 60 Hz -5MT 120/208/240/277/480 V, 60 Hz
-AM 127/220 V, 60 Hz -AK 220/240 V, 60 Hz
-48 480 V, 60 Hz -XQ 120/230 V, 50 Hz
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 65
F1-65
F
Item Description Catalog Number
White Polyester Reectors
For use with globe xtures Standard Dome CMR4-ST*
30 Angle CMR4-AN
Prismatic Glass Globes Heat-Resistant
Clear VPGL-4HR
Closed Prismatic Glass
Refractors Heat-Resistant
NEMA Type II KPRF400-2
NEMA Type V KPRF400-5
Enclosed Reector Assembly
Heat- and impact-resistant glass lens KPR-4HB
Stainless Steel Guards
Globe Guard KPGU400
Refractor Guard KPBG12
Enclosed Reector Guard GHB7000-NG
Mercmaster

III 400
Accessories and Replacement Parts
Refractor Guard
Enclosed Reflector Guard
* Consult factory if used with KPWB or KPST mounting hoods.
Enclosed Reflector
12 Glass Refractor
Glass Globe
Standard Dome 30 Angle
Globe Guard
Effective August, 2008
Copyright 2008
PAGE 66
800-621-1506
www.appletonelec.com

F1-66
F
Mercmaster

III 400
Electrical Specifications and Fuse Kits
Electrical Specifications
C.W.A. Constant Wattage Autotransformer. HX-HPF High Reactance High Power Factor Autotransformer.
Super C.W.A. Super Constant Wattage Autotransformer.
Fuse Kit
Order fuses as a separate item by catalog number from right columns.
Line
Voltage
Type of
Ballast Frequency
Starting
Amps
Operating
Amps
Total
Watts
250-Watt High Pressure Sodium
120 C.W.A. 60 2.00 2.50 295
208 C.W.A. 60 1.20 1.50 295
240 C.W.A. 60 1.00 1.30 295
277 C.W.A. 60 0.85 1.10 295
480 C.W.A. 60 0.40 0.63 310
120 C.W.A. 50 1.85 2.75 300
230 C.W.A. 50 0.95 1.44 300
400-Watt High Pressure Sodium
120 C.W.A. 60 3.30 3.80 465
208 C.W.A. 60 1.80 2.25 465
240 C.W.A. 60 1.60 1.90 465
277 C.W.A. 60 1.40 1.70 465
480 C.W.A. 60 0.80 1.00 465
120 C.W.A. 50 3.70 4.00 465
230 C.W.A. 50 1.85 2.00 465
400-Watt Metal Halide
120 C.W.A. 60 3.50 4.00 458
208 C.W.A. 60 2.00 2.30 458
240 C.W.A. 60 1.75 2.00 458
277 C.W.A. 60 1.50 1.75 458
480 C.W.A. 60 0.90 1.00 465
120 C.W.A. 50 2.70 4.10 462
230 C.W.A. 50 1.40 2.10 462
250-Watt Pulse Start Metal Halide
120 Super C.W.A. 60 1.96 2.50 291
208 Super C.W.A. 60 1.13 1.45 291
240 Super C.W.A. 60 0.98 1.25 291
277 Super C.W.A. 60 0.85 1.10 291
480 C.W.A. 60 0.32 0.69 298
120 Super C.W.A. 50 1.90 2.60 288
230 Super C.W.A. 50 1.00 1.35 288
320-Watt Pulse Start Metal Halide
120 Super C.W.A. 60 3.30 3.25 365
208 Super C.W.A. 60 1.90 1.90 365
240 Super C.W.A. 60 1.60 1.65 365
277 Super C.W.A. 60 1.40 1.40 365
480 Super C.W.A. 60 0.45 0.85 405
120 Super C.W.A. 50 2.28 3.05 365
230 Super C.W.A. 50 1.14 1.60 365
Line
Voltage
Type of
Ballast Frequency
Starting
Amps
Operating
Amps
Total
Watts
350-Watt Pulse Start Metal Halide
120 Super C.W.A. 60 3.60 3.70 400
208 Super C.W.A. 60 2.10 2.10 400
240 Super C.W.A. 60 1.80 1.80 400
277 Super C.W.A. 60 1.60 1.60 400
480 Super C.W.A. 60 0.60 0.90 405
120 Super C.W.A. 50 2.45 3.34 394
230 Super C.W.A. 50 1.26 1.74 394
400-Watt Pulse Start Metal Halide
120 Super C.W.A. 60 3.30 3.80 456
208 Super C.W.A. 60 1.90 2.20 456
240 Super C.W.A. 60 1.60 1.80 456
277 Super C.W.A. 60 1.40 1.65 456
480 Super C.W.A. 60 0.75 1.00 458
120 Super C.W.A. 50 3.17 3.90 454
230 Super C.W.A. 50 1.65 2.00 484
Lamp
Watts Volts
Fuse Quantity
Required
Fuse Catalog Number
HPS MH PSMH
250 120 1 F7 F8
208 2 F4 F5
240 2 F4 F5
277 1 F3 F3
480 2 F2 F2
320 120 1 F8
208 2 F6
240 2 F5
277 1 F4
480 2 F3
350 120 1 F10
208 2 F8
240 2 F5
277 1 F5
480 2 F3
400 120 1 F15 F10 F10
208 2 F8 F8 F7
240 2 F8 F5 F5
277 1 F5 F5 F5
480 2 F5 F4 F4
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 67
F1-67
F
Mercmaster

III 400
Dimensions
Mercmaster III 400 Ballast and Accessory Weights
Weights are approximate. Add 0.25 lb. for Quartz option.
Pendant with Globe,
Guard and Reflectors
Ceiling with Refractor
Enclosed Reflector and Guards
25 Stanchion
Wall
17.23
11.21
9.91
12.09
1
5
.2
7

9
.2
5

8
.1
8

1
2
.
0
7

13.44
11.82
12.38
10.35
14.25DIA
12.25DIA
16.38 DIA
16.63 DIA
11.44
10.38
18.70 DIA
8.80
10.77
10.25
11
6.04
11.65
13.44
1
7
.0
6

D
IA
Cone
90 Stanchion
12.12
Lamp
Watts
Ballast Housing (Wt. Lbs.)
Mounting Hoods
and Reflectors
Wt.
Lbs.
Globe Refractor, Enclosed
Reflector and Guards
Wt.
Lbs. HPS MH PSMH
250 24.5 24.5 Pendant 2.25 Glass Globe 7.0
Pendant Cone 2.50 Globe Guard 3.0
320 28.0 Ceiling 3.00
Wall 4.00 12 Glass Refractor 12.0
350 28.5 25 Stanchion 3.25 Refractor Guard 4.5
90 Stanchion 3.75
400 28.5 26.5 28.5 Standard Dome 3.50 Enclosed Reector 11.0
30 Angle 3.50 Enclosed Reector Guard 2.0
Effective August, 2008
Copyright 2008
PAGE 68
800-621-1506
www.appletonelec.com

F1-68
F
Mercmaster

III 400
Photometric Data
* Photometric data is based on a fixture with a
400-watt clear Metal Halide lamp (36,000 lumen).
For candlepower values of fixtures with other
Metal Halide lamps, use the following multipliers:
For a 250 W (20,500) Metal Halide lamp .570.
For Pulse Start Metal Halide use the following
multipliers: For 250 W (25,000 lumen) .699; 320
W (33,000 lumen) .917; 350 W (37,000 lumen)
1.028; and 400 W (44,000 lumen) 1.222. For
candlepower values of fixture with guard, multiply
by 0.95.
Zone Lumens TOTAL LUMINAIRE EFFICIENCY = 96.2%
REPORT NUMBER: KP40HG 0-10 92.87 CIE Type - General Diffuse
10-20 352.18 Lamps: 400 W Metal Halide with Globe*
20-30 690.95
30-40 1553.44 Coefficients of Utilization - Zonal Cavity Method
40-50 2294.95 Effective Floor Cavity Reflectance 0.20
50-60 2876.38 % Ceiling Rcc 80 70 50 30 10 0
60-70 3403.95 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 3845.88 ZONAL LUMEN SUMMARY 0 104104104104 97 97 97 97 83 83 83 70 70 70 59 59 59 53
80-90 4077.58 Zone Lumens % Lamp % Fixture 1 89 83 77 71 82 76 71 66 64 60 56 53 50 47 43 40 38 33
90-100 4114.28 0-30 1136.01 3.2 3.3 2 79 69 61 54 72 64 56 50 53 47 42 43 39 35 34 31 28 23
100-110 3767.47 0-40 2689.45 7.5 7.8 3 71 59 50 42 65 54 46 39 45 38 33 37 31 27 29 25 21 17
110-120 3244.58 0-60 7860.79 21.8 22.7 4 64 51 41 34 58 47 38 31 39 32 26 31 26 22 25 20 17 13
120-130 2559.03 0-90 19188.20 53.3 55.4 5 58 45 35 28 53 41 32 26 34 27 22 28 22 18 21 17 14 10
130-140 1569.79 90-120 11126.33 30.9 32.1 6 53 39 30 24 49 36 28 22 30 23 18 24 19 15 19 15 11 8
140-150 187.36 90-130 13685.37 38.0 39.5 7 49 35 26 20 45 32 24 19 27 20 15 22 17 12 17 13 10 7
150-160 6.91 90-150 15442.51 42.9 39.5 8 45 32 23 17 41 29 21 16 24 18 13 20 15 11 16 11 8 6
160-170 0.00 90-180 15449.42 42.9 44.6 9 42 29 21 15 38 26 19 14 22 16 12 18 13 9 14 10 7 5
170-180 0.00 0-180 34637.62 96.2 100.0 10 39 26 18 13 36 24 17 12 20 14 10 17 12 8 13 9 6 4
Zone Lumens TOTAL LUMINAIRE EFFICIENCY = 84.9%
REPORT NUMBER: KP40HST 0-10 466.84 CIE Type - Direct
10-20 1418.68
Plane
Spacing
Criteria
Lamps: 400 W Metal Halide with
Standard Dome Reflector*
20-30 2296.77
30-40 3473.07 0-180 1.78 Coefficients of Utilization - Zonal Cavity Method
40-50 4388.44 90-270 1.78 Effective Floor Cavity Reflectance 0.20
50-60 4933.70 Diagonal 1.88 % Ceiling Rcc 80 70 50 30 10 0
60-70 5207.14 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 5010.41 ZONAL LUMEN SUMMARY 0 101101101101 99 99 99 99 94 94 94 90 90 90 86 86 86 84
80-90 3211.97 Zone Lumens % Lamp % Fixture 1 87 81 76 71 85 79 74 70 75 71 67 72 68 65 68 65 63 61
90-100 150.46 0-30 4182.29 11.6 13.7 2 77 68 60 53 75 66 58 52 62 56 51 59 54 50 57 52 48 46
100-110 0.00 0-40 7655.36 21.3 25.1 3 69 57 48 41 66 56 48 41 53 46 40 50 44 39 48 43 38 36
110-120 0.00 0-60 16977.49 47.2 55.6 4 62 50 40 33 60 48 40 33 46 38 32 44 37 32 42 36 31 29
120-130 0.00 0-90 30407.01 84.5 99.5 5 57 43 34 28 55 42 34 27 40 33 27 39 32 27 37 31 26 24
130-140 0.00 90-120 150.46 0.4 0.5 6 52 39 30 23 50 38 29 23 36 28 23 34 28 23 33 27 22 20
140-150 0.00 90-130 150.46 0.4 0.5 7 48 35 26 20 46 34 26 20 32 25 20 31 24 19 30 24 19 17
150-160 0.00 90-150 150.46 0.4 0.5 8 44 31 23 17 43 31 23 17 29 22 17 28 22 17 27 21 17 15
160-170 0.00 90-180 150.46 0.4 0.5 9 41 28 21 15 40 28 20 15 27 20 15 26 20 15 25 19 15 13
170-180 0.00 0-180 30557.47 84.9 100.0 10 39 26 19 14 37 26 18 14 25 18 14 24 18 13 23 17 13 12
Effective August, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 69
F1-69
F
Mercmaster

III 400
Photometric Data
* Photometric data is based on a fixture with a
400-watt clear Metal Halide lamp (36,000 lumen).
For candlepower values of fixtures with other
Metal Halide lamps, use the following multipliers:
For a 250 W (20,500) Metal Halide lamp .570.
For Pulse Start Metal Halide use the following
multipliers: For 250 W (25,000 lumen) .699; 320
W (33,000 lumen) .917; 350 W (37,000 lumen)
1.028; and 400 W (44,000 lumen) 1.222. For
candlepower values of fixture with guard, multiply
by 0.95.
Zone Lumens TOTAL LUMINAIRE EFFICIENCY = 81%
REPORT NUMBER: KP40HAN 0-10 451.78 CIE Type - Direct
10-20 1401.75
Plane
Spacing
Criteria
Lamps: 400 W Metal Halide with
30 Angle Dome Reflector* 20-30 2311.14
30-40 3528.57 0-180 2.16 Coefficients of Utilization - Zonal Cavity Method
40-50 4196.34 90-270 1.86 Effective Floor Cavity Reflectance 0.20
50-60 4223.23 Diagonal 1.78 % Ceiling Rcc 80 70 50 30 10 0
60-70 4035.96 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 3572.75 0 95 95 95 95 92 92 92 92 86 86 86 81 81 81 76 76 76 74
80-90 2785.11 1 83 77 73 68 80 75 70 66 70 66 63 65 62 60 61 59 56 54
90-100 1741.97 ZONAL LUMEN SUMMARY 2 74 65 58 52 71 63 57 51 59 53 49 55 50 47 51 48 44 42
100-110 624.30 Zone Lumens % Lamp % Fixture 3 66 56 48 42 63 54 47 41 50 44 39 47 42 38 44 40 36 34
110-120 140.24 0-30 4164.7 11.6 14.3 4 60 49 41 34 57 47 39 34 44 37 32 41 36 31 39 34 30 28
120-130 75.98 0-40 7693.26 21.4 26.4 5 55 43 35 29 52 42 34 28 39 32 27 36 31 26 34 29 25 23
130-140 61.84 0-60 16112.83 44.8 55.3 6 50 38 30 24 48 37 29 24 35 28 23 33 27 22 31 26 22 20
140-150 0.00 0-90 26506.65 73.6 90.9 7 46 34 27 21 44 33 26 21 31 25 20 29 24 19 28 23 19 17
150-160 0.00 90-120 2506.51 7.0 8.6 8 43 31 24 18 41 30 23 18 28 22 18 27 21 17 25 20 16 15
160-170 0.00 90-130 2582.49 7.2 8.9 9 40 28 21 16 38 27 21 16 26 20 16 25 19 15 23 18 15 13
170-180 0.00 90-150 2644.33 7.3 8.9 10 37 26 19 15 36 25 19 14 24 18 14 23 17 13 21 17 13 12
90-180 2644.33 7.3 9.1
0-180 29150.97 81.0 100.0
Effective August, 2008
Copyright 2008
PAGE 70
800-621-1506
www.appletonelec.com

F1-70
F
Mercmaster

III 400
Photometric Data
* Photometric data is based on a fixture with a
400-watt clear Metal Halide lamp (36,000 lumen).
For candlepower values of fixtures with other
Metal Halide lamps, use the following multipliers:
For a 250 W (20,500) Metal Halide lamp .570.
For Pulse Start Metal Halide use the following
multipliers: For 250 W (25,000 lumen) .699; 320
W (33,000 lumen) .917; 350 W (37,000 lumen)
1.028; and 400 W (44,000 lumen) 1.222. For
candlepower values of fixture with guard, multiply
by 0.95.
Zone Lumens TOTAL LUMINAIRE EFFICIENCY = 76.8%
REPORT NUMBER: KP40HJ5 0-10 361.67 CIE Type - Semi-Direct
10-20 940.65
Plane
Spacing
Criteria
Lamps: 400 W Metal Halide with
8 Prismatic Glass Refracter - NEMA Type V*
20-30 1459.40
30-40 2154.18 0-180 1.20 Coefficients of Utilization - Zonal Cavity Method
40-50 3253.34 90-270 1.20 Effective Floor Cavity Reflectance 0.20
50-60 4959.71 Diagonal 2.06 % Floors Rfc 20
60-70 5263.43 % Ceiling Rcc 80 70 50 30 10 0
70-80 2867.04 ZONAL LUMEN SUMMARY % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
80-90 1839.10 Zone Lumens % Lamp % Fixture 0 88 88 88 88 85 85 85 85 78 78 78 72 72 72 67 67 67 64
90-100 1369.62 0-30 2761.72 7.7 10.0 1 78 73 68 65 74 70 66 62 64 61 58 59 56 54 54 52 50 47
100-110 920.16 0-40 4915.90 13.7 17.8 2 69 61 54 49 65 58 52 47 53 48 44 49 45 41 45 41 39 36
110-120 853.41 0-60 13128.96 36.5 47.5 3 61 52 44 38 58 49 42 37 45 39 35 41 36 32 38 34 30 28
120-130 680.24 0-90 23098.52 64.2 83.5 4 55 44 37 30 52 42 35 30 39 33 28 35 30 26 32 28 24 22
130-140 444.86 90-120 3143.19 8.7 11.4 5 50 39 31 25 47 37 30 24 34 28 23 31 26 21 28 24 20 18
140-150 215.06 90-130 3823.43 10.6 13.8 6 46 34 26 21 43 33 25 20 30 24 19 27 22 18 25 20 17 15
150-160 70.22 90-150 4483.35 12.5 13.8 7 42 30 23 18 40 29 22 17 27 21 16 24 19 15 22 18 14 12
160-170 6.67 90-180 4560.35 12.7 16.5 8 39 27 20 15 37 26 20 15 24 18 14 22 17 13 20 16 12 10
170-180 0.10 0-180 27658.88 76.8 100.0 9 36 25 18 13 34 24 17 13 22 16 12 20 15 11 19 14 11 9
10 34 23 16 12 32 22 16 11 20 15 11 19 14 10 17 13 10 8
Zone Lumens TOTAL LUMINAIRE EFFICIENCY = 65.9%
REPORT NUMBER: KP40HHB 0-10 389.64 CIE Type - Direct
10-20 1322.24
Plane
Spacing
Criteria
Lamps: 400 W Metal Halide with
Enclosed Reflector (KPR-4HB)*
20-30 2646.72
30-40 4368.37 0-180 2.46 Coefficients of Utilization - Zonal Cavity Method
40-50 6017.88 90-270 2.46 Effective Floor Cavity Reflectance 0.20
50-60 5490.81 Diagonal 2.14 % Floors Rfc 20
60-70 2583.38 % Ceiling Rcc 80 70 50 30 10 0
70-80 802.50 ZONAL LUMEN SUMMARY % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
80-90 92.80 Zone Lumens % Lamp % Fixture 0 78 78 78 78 77 77 77 77 73 73 73 70 70 70 67 67 67 66
90-100 0.41 0-30 4358.61 12.1 18.4 1 72 69 66 64 70 68 65 63 65 63 61 62 61 59 60 59 57 56
100-110 0.00 0-40 8726.97 24.2 36.8 2 65 60 56 52 64 59 55 51 57 53 50 54 52 49 52 50 48 47
110-120 0.00 0-60 20235.66 56.2 85.3 3 59 52 47 43 58 51 46 42 49 45 41 47 44 41 46 43 40 39
120-130 0.00 0-90 23714.31 65.9 100.0 4 54 46 40 35 52 45 39 35 43 38 35 42 37 34 40 37 34 32
130-140 0.00 90-120 0.41 0.0 0.0 5 49 40 34 30 48 40 34 29 38 33 29 37 32 29 36 32 29 27
140-150 0.00 90-130 0.41 0.0 0.0 6 45 36 30 25 44 35 29 25 34 29 25 33 28 25 32 28 24 23
150-160 0.00 90-150 0.41 0.0 0.0 7 41 32 26 22 40 31 26 22 30 25 21 29 25 21 28 24 21 20
160-170 0.00 90-180 0.41 0.0 0.0 8 38 29 23 19 37 28 23 19 27 22 19 26 22 18 26 21 18 17
170-180 0.00 0-180 23714.75 65.9 100.0 9 35 26 20 16 34 26 20 16 25 20 16 24 19 16 23 19 16 15
10 33 24 18 15 32 23 18 14 23 18 14 22 17 14 21 17 14 13
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 71
F1-71
F
Wallmaster I/2
Enclosed and Gasketed for Hazardous and Wet Locations
Wall Mounted, Integrally Ballasted Luminaire for 70 W, 100 W and 150 W
High Pressure Sodium Lamps for Class I, Div. 2/Zone 2 Hazardous Locations.
Applications
Wall mounted luminaire suitable for
outdoor applications.
Areas where flammable gases are
present under conditions defines by
NEC Class I, Div. 2.
Features
Attractive yet rugged design.
Side hinged door allows
unobstructed access to lamp and
wiring components.
Built in stop limits door opening to
90and protects the lens from
breakage.
Latch Mechanism: Unique heavy-
duty stainless steel latch secures
the cover assembly while allowing
the luminaire to be relamped with-
out the use of tools.
Prismatic tempered glass lens is
thermal-shock- and impact-resistant
giving a soft diffused light.
Installation is fast and easy.
Luminaire is furnished with two
plugged 1/2 conduit entries. A 1/2
knockout allows rear entry.
Mogul Base Socket is heavy-duty
porcelain with heavy gauge brass
nickel plated double lamp grip screw
shell and spring loaded center
contacts.
Aluminum reflector is designed for
maximum efficiency.
Standard finish is architectural
bronze tone baked epoxy.
Complances
CSA approved for hazardous loca-
tions (LR25428).
Class I, Div. 2
Class I, Zone 2
cCSAus
14
12-1/8
5-7/16
Effective September, 2008
Copyright 2008
PAGE 72
800-621-1506
www.appletonelec.com

F1-72
F
Accessories
Guard Vandal Shield
Stainless steel plated GWMWG UV stabilized polycarbonate.
Can be used with guard.
GWMLS
Replacement Lens
Clear GWML
SERIES:
GWM - Wallmaster
VOLTAGE:
48 - 480
MT - 120/208/240/277
BU - 120-277, 50/60 Hz
(Fluorescent Only)
OPTIONS:
R - Hot Restrike
S - Safety Starter
Q - Hazardous
Photocell
CATALOG NUMBERING GUIDE FOR WALMASTER I/2
GWM 70 L MT H R
LAMP TYPE:
L - High Pressure
Sodium
F - Fluorescent
CSA Listed
Class I, Div. 2, Groups A,B,C,D
Class I, Zone 2, Groups IIA,IIB,IIC
WATTAGE:
70 - 70 W HPS
10 - 100 W HPS
15 - 150 W HPS
36 - Two 18 W PL-T
52 - Two 26 W PL-T
64 - Two 32 W PL-T
T Numbers for Wallmaster I/2 Fixtures:
Lamp
Watts
Lamp
Type
Supply
Wire C
Maximum Ambient
Temperature C
Class I, Div. 2
Class I, Zone 2
70 HPS 125 40 T2D
100 HPS 125 25 T2C
150 HPS 125 25 T2A
36 Fluorescent 125
40
55
T3
52 Fluorescent 125
40
55
T3
64 Fluorescent 125
40
55
T3
RATINGS:
H - Hazardous Location
T Numbers Represent the Maximum Lamp Temperature for Class I, Div. 2 Locations
T
Number
T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp
Range
(C)
351-450 326-350 301-325 382-300 261-280 231-260 216-230 201-215 181-200 166-180 161-165 136-160 121-135 101-120 86-100 85
Wallmaster I/2
Enclosed and Gasketed for Hazardous and Wet Locations
Wall Mounted, Integrally Ballasted Luminaire for 70 W, 100 W and 150 W
High Pressure Sodium Lamps and Compact Fluorescent for Class I, Div. 2/Zone 2 Hazardous Locations.
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 73
F1-73
F
Zone 2 Areamaster

250/400
Integrally ballasted floodlights for 70 W, 100 W, 150 W, 250 W and 400 W High Pressure Sodium; 175 W, 250 W
and 400 W Metal Halide; and 200 W, 250 W, 320 W and 400 W Pulse Start Metal Halide. For Class I, Zone 2 AEx
nR, Groups IIA, IIB, IIC locations.
Applications
Powerful, efficient weatherproof
floodlights for use in areas where
flammable gases and vapors are
present under conditions defined as
Zone 2. The method of protection
for the Zone 2 Areamaster 250/400
is Restricted Breathing.
Fixtures are also well suited for use
in non-hazardous areas where severe
weather conditions and excessive
moisture are encountered.
Typical applications include pulp
and paper mills, processing plants,
oil refineries, foundries, manufactur-
ing plants and storage areas.
Features
Compact in size, attractively styled
contemporary design, rugged and
dependable.
Easy to install and service.
Integral ballast; choice of multi-tap
for 120, 208, 240 or 277 V lines, or
for 480V lines.
Yoke mount, zinc plated steel yoke
with architectural bronze POLYES-
TER finish.
Zone 2 fixtures include terminal
blocks. A seven-point terminal block
is provided to facilitate wiring. Termi-
nal block accommodates wire size
ranging from #8 to #24 AWG.
Cool operating temperatures trans-
late into long luminaire life.
Standard Materials and Finishes
Housing: one-piece pressure-cast
copper-free aluminum with architec-
tural bronze POLYESTER finish.
Lens door: one-piece pressure-cast
copper-free aluminum with archi-
tectural bronze POLYESTER finish.
Secured by four 1/4 dia. captive
stainless steel slotted hex-head
bolts.
Lens: thermal-shock- and impact-
resistant glass.
Gasket: heavy-duty, high-tempera-
ture silicone rubber, firmly sealed.
Socket: heavy-duty, mogul base
porcelain with heavy gauge brass,
nickel plated, double lamp-grip
screw shell and spring loaded cen-
ter contact.
Projected area:
1.9 Sq. Ft.
Reflector: compound parabolic,
double segment, Alzak

finished alu-
minum for optimum efficiency.
Appleton aluminum products are
produced from a high-strength cop-
per-free (4/10 of 1% max.) alloy.
Compliances
UL 2279
Class I, Zone 2 AEx nR IIC, IP66
Effective September, 2008
Copyright 2008
PAGE 74
800-621-1506
www.appletonelec.com

F1-74
F
Class I, Zone 2
AEx nR IIC IP66
Ordering Information
Lamp
Line
Voltage
Yoke Mounting
Catalog Number
Supply
Wire C
Ambient
Temp C
Class I, Zone 2
Temp Code Temp. C
High Pressure Sodium
400 W HPS
120/208/240/277 G-AM771L-MT-Z2 105 40 T3 200
120/220-240 G-AM771L-XP-Z2* 110 50 T3 200
480 G-AM771L-48-Z2
250 W HPS
120/208/240/277 G-AM671L-MT-Z2 75 40 T4 135
120/220-240 G-AM671L-XP-Z2* 90 55 T3 200
480 G-AM671L-48-Z2 105 65 T3 200
150 W HPS
120/208/240/277 G-AML471L-MT-Z2 85 40 T4 135
120/220-240 G-AML471L-GP-Z2* 105 55 T4 135
480 G-AML471L-48-Z2 110 65 T3 200
100 W HPS
120/208/240/277 G-AML371L-MT-Z2 75 40 T5 100
120/220/240 G-AML371L-GP-Z2* 90 55 T4 135
480 G-AML371L-48-Z2 105 65 T4 135
70 W HPS
120/208/240/277 G-AML271L-MT-Z2 75 40 T6 85
120/220/240 G-AML271L-GP-Z2* 90 55 T5 100
480 G-AML271L-48-Z2 105 65 T4 135
Pulse Start Metal Halide
400 W PSMH
120/208/240/277 G-AM771P-MT-Z2 105 40 T3 200
120/220-240 G-AM771P-XP-Z2* 105 55 T3 200
480 G-AM771P-48-Z2
320 W PSMH
120/208/240/277 G-AM3271P-MT-Z2 105 40 T3 200
120/220-240 G-AM3271P-XP-Z2
480 G-AM3271P-48-Z2
250 W PSMH
120/208/240/277 G-AM671P-MT-Z2 85 40 T3 200
120/230 G-AM671P-XQ-Z2* 105 55 T3 200
480 G-AM671P-48-Z2 110 65 T3 200
200 W PSMH
120/208/240/277 G-AM2071P-MT-Z2 75 40 T3 135
120/230 G-AM2071P-XQ-Z2* 85 55 T3 200
480 G-AM2071P-48-Z2 105 65 T3 200
Metal Halide
400 W MH
120/208/240/277 G-AM771H-MT-Z2 105 40 T3 200
120/230 G-AM771H-XQ-Z2*
480 G-AM771H-48-Z2
250 W MH
120/208/240/277 G-AM671H-MT-Z2 85 40 T3 200
120/230 G-AM671H-XQ-Z2* 105 55 T3 200
480 G-AM671H-48-Z2 110 65 T3 200
175 W MH
120/208/240/277 G-AM571H-MT-Z2 90 40 T4 135
120/230 G-AM571H-XQ-Z2* 105 55 T3 200
480 G-AM571H-48-Z2 110 65 T3 200
*50 Hz
NOTE: For Class I, Div. 2 Areamaster 250/400, see catalog section Q.
T Numbers represent the maximum surface temperature for luminaries with AEx nR rating:
T Number T1 T2 T3 T4 T5 T6
Temp. Range (C) 301-450 201-300 136-200 101-135 86-100 85
To comply with AEx nR requirements, all wiring entries must be sealed.
Zone 2 Areamaster

250/400
Integrally ballasted floodlights for 70 W, 100 W, 150 W, 250 W and 400 W High Pressure Sodium; 175 W, 250 W
and 400 W Metal Halide; and 200 W, 250 W, 320 W and 400 W Pulse Start Metal Halide. For Class I, Zone 2 AEx
nR, Groups IIA, IIB, IIC locations.
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 75
F1-75
F
Vandal Shield
UV stabilized polycarbonate,
with installation hardware and
instructions.
G-AM-6-VS
Top Visor
Easy to install with hardware sup-
plied. Aluminum, with architectural
bronze POLYESTER finish.
G-AM-6-V
16"
12-7/8"
16"
5-1/4"
8-1/4"
2-5/16"
4-7/16"
5/8"
3/8"
5"
4-7/8"
5"
3"
5-1/2"
4-1/2"
4-9/16"
2-1/2"
2-7/8"
2"
Mounting Fittings and Accessories
Dimensions Description Catalog Number Dimensions Description Catalog Number
Pipe or Wall
Mount Bracket
Used with G-AM-8-CA. Clamps
to 1 to 2-1/2 pipe, vertical or
horizontal, or mounts on flat
surfaces. Includes U-bolt and
crossarm bracket bolts. Malleable
iron, zinc plated, chromate
sealed, with architectural bronze
POLYESTER finish.
G-AM-8-WB
Poletop Slip-Fitter
Slip-fits 1-1/2 or 2 pipe size
poletop tenons. Includes flood-
light yoke bolts, 3 locking bolts,
and cord grip. Body is mal-
leable iron, zinc plated, chromate
sealed, with cast aluminum
cap. Assembly has architectural
bronze POLYESTER finish.
G-SF20
Crossarm
Mounting Bracket
Has 180horizontal adjustment
degree marked. Facilitates mount-
ing floodlight to crossarm or other
flat surface, or to G-AM-8-WB.
Includes floodlight yoke bolts.
Malleable iron, zinc plated, chro-
mate sealed, architectural bronze
POLYESTER finish.
G-AM-8-CA
Replacement Lens
604249003
5-1/4
16
8-1/4
Zone 2 Areamaster

250/400
Accessories
Integrally ballasted floodlights for 70 W, 100 W, 150 W, 250 W and 400 W High Pressure Sodium; 175 W, 250 W
and 400 W Metal Halide; and 200 W, 250 W, 320 W and 400 W Pulse Start Metal Halide. For Class I, Zone 2 AEx
nR, Groups IIA, IIB, IIC locations.
Effective September, 2008
Copyright 2008
PAGE 76
800-621-1506
www.appletonelec.com

F1-76
F
Electrical Specifications
Line
Voltage Frequency
Type of
Ballast
Starting
Amps
Operating
Amps
Total
Watts
70-Watt High Pressure Sodium
120 60 HX-HPF 0.90 0.82 94
208 60 HX-HPF 0.50 0.48 94
240 60 HX-HPF 0.44 0.41 94
277 60 HX-HPF 0.35 0.36 94
480 60 HX-HPF 0.21 0.21 94
120 50 HX-HPF 1.08 0.81 97
220 50 HX-HPF 0.59 0.49 97
240 50 HX-HPF 0.54 0.45 97
100-Watt High Pressure Sodium
120 60 HX-HPF 1.30 1.15 130
208 60 HX-HPF 0.76 0.67 130
240 60 HX-HPF 0.66 0.58 130
277 60 HX-HPF 0.60 0.50 130
480 60 HX-HPF 0.33 0.31 135
120 50 HX-HPF 0.90 1.20 130
220 50 HX-HPF 0.50 0.65 130
240 50 HX-HPF 0.45 0.60 130
150-Watt High Pressure Sodium
120 60 HX-HPF 2.00 1.66 189
208 60 HX-HPF 1.16 0.96 189
240 60 HX-HPF 1.00 0.83 189
277 60 HX-HPF 0.86 0.75 189
480 60 HX-HPF 0.50 0.44 189
120 50 HX-HPF 1.50 1.60 188
220 50 HX-HPF 0.85 0.90 188
240 50 HX-HPF 0.75 0.80 188
250-Watt High Pressure Sodium
120 60 CWA 1.75 2.70 300
208 60 CWA 1.00 1.50 300
240 60 CWA 0.85 1.30 300
277 60 CWA 0.75 1.15 300
480 60 CWA 0.40 0.65 295
120 50 CWA 1.85 2.75 300
220 50 CWA 0.95 1.44 300
240 50 CWA 0.95 1.44 300
400-Watt High Pressure Sodium
120 60 CWA 3.10 3.90 465
208 60 CWA 1.80 2.25 465
240 60 CWA 1.60 1.95 465
277 60 CWA 1.35 1.70 465
480 60 CWA 0.80 1.00 465
120 50 CWA 3.70 4.00 465
220 50 CWA 1.85 2.00 465
240 50 CWA 1.85 2.00 465
175-Watt Metal Halide
120 60 CWA 1.30 1.80 213
208 60 CWA 0.75 1.10 213
240 60 CWA 0.65 0.90 213
277 60 CWA 0.55 0.80 213
480 60 CWA 0.35 0.45 213
120 50 CWA 1.70 1.90 210
220 50 CWA 0.80 1.10 210
Line
Voltage Frequency
Type of
Ballast
Starting
Amps
Operating
Amps
Total
Watts
250-Watt Metal Halide
120 60 CWA 1.20 2.60 295
208 60 CWA 0.65 1.50 295
240 60 CWA 0.60 1.30 295
277 60 CWA 0.50 1.12 295
480 60 CWA 0.30 0.65 298
120 50 CWA 2.00 2.50 285
220 50 CWA 0.94 1.30 285
240 50 CWA 0.85 1.25 285
400-Watt Metal Halide
120 60 CWA 3.25 4.00 458
208 60 CWA 1.90 2.30 458
240 60 CWA 1.65 2.00 458
277 60 CWA 1.40 1.75 458
480 60 CWA 0.85 1.00 462
120 50 CWA 2.70 4.10 480
220 50 CWA 1.50 2.20 480
240 50 CWA 1.30 2.00 480
200-Watt Pulse Start Metal Halide
120 60 Super CWA 1.15 2.20 232
208 60 Super CWA 0.65 1.25 232
240 60 Super CWA 0.55 1.10 232
277 60 Super CWA 0.49 0.95 232
480 60 Super CWA 0.19 0.54 232
120 50 Super CWA 1.60 2.10 244
230 50 Super CWA 0.84 1.10 244
250-Watt Pulse Start Metal Halide
120 60 Super CWA 1.96 2.50 291
208 60 Super CWA 1.13 1.45 291
240 60 Super CWA 0.98 1.25 291
277 60 Super CWA 0.85 1.10 291
480 60 Super CWA 0.32 0.69 298
120 50 Super CWA 1.90 2.60 288
230 50 Super CWA 1.00 1.35 288
320-Watt Pulse Start Metal Halide
120 60 Super CWA 3.30 3.25 365
208 60 Super CWA 1.90 1.90 365
240 60 Super CWA 1.60 1.65 365
277 60 Super CWA 1.40 1.40 365
480 60 Super CWA 0.45 0.85 405
120 50 Super CWA 2.28 3.05 365
230 50 Super CWA 1.14 1.60 365
400-Watt Pulse Start Metal Halide
120 60 Super CWA 3.30 3.90 456
208 60 Super CWA 1.90 2.20 456
240 60 Super CWA 1.60 1.80 456
277 60 Super CWA 1.40 1.65 456
480 60 Super CWA 0.75 1.00 458
120 50 Super CWA 3.17 3.90 454
230 50 Super CWA 1.65 2.00 454
Zone 2 Areamaster

250/400
Electrical Specifications
Integrally ballasted floodlights for 70 W, 100 W, 150 W, 250 W and 400 W High Pressure Sodium; 175 W, 250 W
and 400 W Metal Halide; and 200 W, 250 W, 320 W and 400 W Pulse Start Metal Halide. For Class I, Zone 2 AEx
nR, Groups IIA, IIB, IIC locations.
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 77
F1-77
F
Photometric charts available on request.
(i.e. ratio of distance to height. Example: @ 20 mounting height, 1 means 20; 2 means 40, etc.)
* For 100 W HPS lamps, multiply footcandle values by 1.5. For 150W HPS lamps, multiply footcandle values by 2.5.
** For 175 W MH lamps, multiply footcandle values by 0.64.
G
H
I
J
K
L
0 1.0
1.0
.5
1.0
2.0
3.0
2.0 3.0
D
i
s
t
a
n
c
e

i
n

t
e
r
m
s

o
f

m
o
u
n
t
i
n
g

h
e
i
g
h
t

Distance in terms of mounting height


45
MH
A
B
C
D
E
F
.5
0
1.0
1.5
2.0
2.5
3.0
D
i
s
t
a
n
c
e

i
n

t
e
r
m
s

o
f

m
o
u
n
t
i
n
g

h
e
i
g
h
t

0 .5 1.0 1.5 2.0


Distance in terms of mounting height
45
MH
Typical Footcandle Values
Mtg.
Ht.
Ft. Cdles for Iso-Footcandle Lines
G H I J K L
70 W HPS*
10 10.00 5.00 2.50 1.00 0.50 0.25
20 2.50 1.00 0.50 0.25 0.10 0.05
30 1.00 0.50 0.25 0.10 0.05 0.02
Mtg.
Ht.
Ft. Cdles for Iso-Footcandle Lines
Mtg.
Ht.
Ft. Cdles for Iso-Footcandle Lines
A B C D E F A B C D E F
250 W HPS 250 W MH**
60 1.96 1.64 1.09 0.55 0.22 0.11 60 1.40 1.00 0.60 0.35 0.20 0.10
50 2.84 2.40 1.74 0.82 0.31 0.16 50 2.00 1.40 0.90 0.46 0.29 0.15
40 4.58 3.76 2.62 1.36 0.49 0.26 40 3.30 2.18 1.40 0.80 0.45 0.22
30 7.85 6.54 4.69 2.08 0.87 0.46 30 5.90 4.70 2.40 1.30 0.80 0.41
20 16.90 15.30 10.40 4.36 2.07 1.09 20 10.40 8.80 5.60 3.20 1.90 0.90
400 W HPS 400 W MH
60 3.27 2.74 1.82 0.92 0.37 0.18 60 2.32 1.66 1.00 0.58 0.33 0.17
50 4.74 4.00 2.90 1.37 0.52 0.27 50 3.32 2.32 1.49 0.76 0.48 0.25
40 7.65 6.28 4.38 2.27 0.82 0.43 40 5.48 3.62 2.32 1.33 0.75 0.36
30 3.10 10.92 7.83 3.47 1.45 0.77 30 9.79 7.80 3.98 2.16 1.33 0.68
20 28.22 25.55 17.37 7.28 3.46 1.82 20 17.26 14.60 9.30 5.31 3.15 1.49
Zone 2 Areamaster

250/400
Photometric Data
Effective September, 2008
Copyright 2008
PAGE 78
800-621-1506
www.appletonelec.com

F1-78
F
Mercmaster

II HID
Enclosed and Gasketed Lighting Fixtures
High Pressure Sodium and Metal Halide Mogul Base Lamps. For Use with Threaded Metal Conduit.
Applications
Enclosed and gasketed HID light-
ing fixtures for use in tunnels,
walkways, bridges, storage facili-
ties, processing plants, parking lots,
foundries, manufacturing plants,
power plants and other locations
where moisture, dirt, dust or corro-
sive atmospheres are encountered.
Fixtures suited for Class I, Div. 2;
Class II, Div. 1 and 2; and Class III.
Suitable for use in wet and outdoor
saltwater locations.
Wide range of wattages and voltages.
Choice of ballasts for 50 though
250 W MH, 150 W HPS lamps in
120, 208, 240, 277 and 480 voltages.
Choice of light sources: high pres-
sure sodium and metal halide.
Choice of optical assembles: (1)
prismatic globe with or without guard
through 250 W; or (2) Type V closed
prismatic glass refractor through
250 W. (Types II, III and IV also
available through 250 W. Also poly-
carbonate globes for 100 W max.)
Choice of mounting hoods: pendant
(rigid or flexible), 25(angle) stan-
chion, ceiling and wall mounting.
Porcelain reflector for standard appli-
cations and fiberglass-reinforced poly-
ester reflector for installations where
luminaire is subject to exceptionally
severe corrosive atmospheres.
Features
Superior corrosion-resistance: cop-
per-free aluminum mounting hoods,
ballasts and guards with epoxy
powder coat, inside and out.
Standard pendant mounting hood
for rigid or flexible mounting. Bal-
anced round design automatically
hangs plumb when used with flex-
ible hanger.
Positive sealing. Hinge and bolt con-
struction assures 360compression
at all points on gasket.
One-piece ballast housing for each
component provides even heat dis-
sipation for cooler operation and
longer ballast life.
Heat barrier isolates capacitor from
ballast. Standard non-PCB bio-
degradable capacitors installed in
separate compartment.
Fixture with Prismatic Globe,
Guard and Polyester Reflector
Fixture with
Prismatic Globe and Guard
Fixture with Prismatic
Glass Refractor
Mogul socket is furnished with 200 C
welded leads, pre-wired to the ballast.
Porcelain socket assures trouble-free
operation in high ambient installations.
HID Stylmaster fixtures ideal where
mounting height is restricted and
remote HID ballasts are required.
Guards protect globes from dam-
age. Keyhole slots allow easy
installation and are secured with
stainless steel screws.
Prismatic glass globes and glass
refractors are standard (plastic refrac-
tors also available) and thread directly
into fixture housing. Eliminate glare
and provide uniform light distribution.
Vented reflectors result in cooler,
dirt-free operation, increased lumen
output.
Reflectors secured to mounting
hood with screws (furnished).
Choice of reflector styles: white
porcelain enamel or fiberglass-rein-
forced polyester; standard dome or
30angle.
Optional photocell provides auto-
matic on-off control.
All Mercmaster mounting hoods have
provision for easy field installation of
fuses in fixtures (see fuse kit listings).
Standard Materials
Mounting hoods, ballast bodies and
guards: aluminum (copper-free
4/10 of 1% max.).
Reflectors: fiberglass-reinforced
polyester.
Globes: 50 W-100 W, threaded
prismatic glass; 150 W, 175 W and
250W, threaded heat-resistant pris-
matic glass.
Refractors: 50 W to 150 W, heat-
resistant prismatic glass and plastic;
175 W to 250 W, prismatic glass.
Enclosed reflector: etched Alzak
aluminum (copper-free 4/10 of 1%)
with sealed, tempered heat- and
impact-resistant lens.
Standard Finishes
Mounting hoods, ballast bodies,
guards: epoxy powder-coat finish.
Two-coat baked finish, electrostati-
cally applied for complete uniform
surface protection.
Polyester reflectors: natural finish.
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 79
F1-79
F
Mercmaster

II HID
Enclosed and Gasketed Lighting Fixtures
High Pressure Sodium and Metal Halide Mogul Base Luminaires. UNILETS for Use with Threaded Metal Conduit.
Options
Fuses for fixtures. See listings.
MH fixtures for Quartz Auxiliary
lamps. Relay switch installed in
fixture when specified. Add suffix
-MTE to fixture catalog number for
120 V through 277 V, and suffix
-480E to fixture catalog number for
480 V fixture.
Smart Hot Restrike emergency option,
available for 50 W-150 W HPS only.
Add suffix -SR. See page F1-20.
Hot Restrike option add suffix -R.
Smart Starter available for 50-150W
HPS add suffix -S.
Compliances
UL Listed
UL Standard 1598A, 844 and Marine
Type Electric Fixtures Outside Type
(Salt Water)
Suitable for use in wet locations
Class I, Div. 2, Groups A,B,C,D
Class II, Div. 1 and 2, Groups E,F,G
References
For additional data on lamp and
lighting fixture selection, see gen-
eral introduction to catalog.
Note: Fixtures equipped with optional photocell
or quartz auxilliary lamp do not comply with
UL requirements and are not suitable for use
in classfied locations.
Mercmaster Fixture and Accessory Weights
Mounting Hoods
Pendant: 3 lbs. Ceiling: 5 lbs. Wall: 5 lbs. Stanchion: 4 lbs.
Wt. Lbs.
(includes globe and guard)
Matching Reflectors and Refractors
Standard Dome 30 Angle 8 Refractor 12 Refractor
Watts HPS MH
Catalog
Number
Wt.
Lbs.
Catalog
Number
Wt.
Lbs.
Catalog
Number
Wt.
Lbs.
Catalog
Number
Wt.
Lbs.
50, 70 14
100 15 KR2-ST 2.5 KR2-AN 2.5 LPG-R1 5.25 LPRF-5CG 13
150 16 LPG-R3 5.25
175 16 LPG-R5 5.25
Effective September, 2008
Copyright 2008
PAGE 80
800-621-1506
www.appletonelec.com

F1-80
F
Epoxy Finish
Gasketed ballast housing and hood are
copper-free aluminum with epoxy pow-
der coat finish.
Mercmaster

II HID
Illustrated Features: Enclosed and Gasketed Lighting Fixtures
Electrical Protection
Ground wire provided to bond mounting
hood to ballast housing. Fiber insulator
protects ballast and capacitor.
Aluminum Inner Reflector
Solid aluminum inner reflector not just
aluminum foil
Fuses Mount to Hood Bosses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
JB Series Box
and Flexible
Hanger
Balanced Round Design
Pendant fixtures automatically hang
plumb. Fixtures and hangers suitable for
Class I, Div. 2 applications.
Hood/Ballast Gasket
Silicone rubber gasket seals out mois-
ture, dirt and dust.
Photocell
Installs through knock-out in mounting
hood; provides continuous ON-OFF
dusk-to-dawn control. Fixtures with
optional photocell or quartz auxiliary
lamp do not comply with UL require-
ments for use in classified locations.
Safety High Hinge
Provides extra protection
against accidental ballast
housing disengagement during
installation or maintenance.
Stainless Steel Latch Assembly
Captive, stainless steel
latch assembly closes
securely, resists attack of
corrosive atmospheres.
High-Temperature Socket
Mogul base high temperature socket for
50W through 400W HID lamps.
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 81
F1-81
F
Mercmaster

II HID
Technical Data: Thermal Suitability
Class I, Div. 2, Groups A, B, C and D; Class II, Div. 1, Groups E, F and G
The following table shows maximum
operating temperatures of Mercmaster
fixtures for Class I, Div. 2, in a 40 C
ambient in free air as rated by UL. As
shown, the higher the Temperature
Identification Number, the cooler the
fixture operates. Keep this in mind
when selecting a fixture for a specific
chemical listed on pages F1-114 and
F1-115. Per NEC 500-2(c), the tem-
perature marking shown on fixtures
shall not exceed the ignition tempera-
ture of the gas to be encountered. To
illustrate, a 400W HPS fixture, which
has a UL-NEC Temperature Identifi-
cation Number of 350 (326-350 C)
does NOT exceed the Group D Meth-
ane (natural gas) ignition temperature
of 540 C shown on page F1-115,
and is therefore suitable for use in
atmospheres containing that chemical.
Mercmaster II Thermal Suitability
Lamp Supply
Wire
Temp.
C
Ambient
Temp.
C
Class I, Div. 2, Groups A, B, C, D Class II, Div. 1, Groups E, F G
Watts Type Globe
Globe &
Reflector
8
Refractor
12
Refractor Globe
Globe &
Reflector
8
Refractor
12
Refractor
50 HPS 90 40 T3 T3 T3A T3A T3B T3B T3B T3B
70 HPS 90 40 T3 T3 T3A T3A T3B T3B T3B T3B
100 HPS 90 40 T2C T2C T2D T3 T3B T3B T3B T3B
150 HPS 90 40 T2A T2A T2B T2B T3B
175 MH 90 40 T2A T2A T2C T2C T3B
250 MH 90 40 350 350 325 T2 T3B
Pendant, ceiling and wall mount are suitable for groups E and F only with T3A rating. Stanchion mount is suitable for groups E, F and G with a T3B rating.
All HPS xtures suitable for operation at -40 F; MH at -20 F.
T Numbers Represent the Maximum Lamp Temperature for Class I, Div. 2 Locations and Maximum Surface Temperature Under Dust
Blanket for Class II, Div. 1 Locations.
T
Number
T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp
Range
(C)
351-450 326-350 301-325 281-300 261-280 231-260 216-230 201-215 181-200 166-180 161-165 136-160 121-135 101-120 86-100 85
Effective September, 2008
Copyright 2008
PAGE 82
800-621-1506
www.appletonelec.com

F1-82
F
Mercmaster

II HID
Classified Area Suitability
Maximum Temperatures in C Obtained from Tests in a 40 C Ambient, Vertical Position, Lamp Base Up, as per NEC.
Fixture Selection Guide* Indicates atmosphere for which xture is suitable.
1 Indicates Globe with or without reflector 2 Indicates 12 Refractor 3 Indicates 8 Refractor
Class I, Div. 2 Chemical Ignitition C
Min. Fixture
T Number
for Chemical
HPS (Watts) MH (Watts)
50, 70 100 150 175 250
Group A Atmospheres
acetylene 305 T2 123 123 123 123 2
Group B Atmospheres
acrolein (inhibited) 220 T2D 123 2
arsine NA
butadiene 420 350 123 123 123 123 123
ethylene oxide 429 350 123 123 123 123 123
hydrogen 500 T1 123 123 123 123 123
propylene oxide 449 350 123 123 123 123 123
propylnitrate 175 T3B
Group C Atmospheres
acetaldehyde 175 T3B
allyl alcohol 378 350 123 123 123 123 123
n-butyraldehyde 218 T2D 123 2
carbon monoxide 609 T1 123 123 123 123 123
crotonaldehyde 232 T2C 123 123 2
cyclopropane 498 T1 123 123 123 123 123
diethyl ether (ethyl ether) 160 T3C
diethylamine 312 T2 123 123 123 123 2
ethylene 450 T1 123 123 123 123 123
ethylenimine 320 T2 123 123 123 123 2
ethly mercaptan 300 T2 123 123 123 123 2
ethyl sulde NA
hydrogen cyanide 538 T1 123 123 123 123 123
hydrogen sulde 260 T2B 123 123 23 2
morpholine 310 T2 123 123 123 123 2
2-nitropropane 428 350 123 123 123 123 123
tetrahydrofuran 321 T2 123 123 123 123 2
unsymmetrical dimethyl hydrazine 249 T2C 123 123 2
Group D Atmospheres
acetic acid (glacial) 464 T1 123 123 123 123 123
acetone 465 T1 123 123 123 123 123
acrylonitrile 481 T1 123 123 123 123 123
ammonia 651 T1 123 123 123 123 123
benzene 498 T1 123 123 123 123 123
butane 287 T2A 123 123 123 123
1-butanol (butyl alcohol) 343 325 123 123 123 123 2
2-butanol (secondary butyl alcohol) 405 350 123 123 123 123 123
Group D atmosphere designations continued on next page. See next page for additional notes
50 Watt is suitable with 12 Refractor.
Not available.
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 83
F1-83
F
Fixture Selection Guide* Indicates atmosphere for which xture is suitable.
1 Indicates Globe with or without reflector 2 Indicates 12 Refractor 3 Indicates 8 Refractor
Class I, Div. 2 Chemical Ignitition C
Min. Fixture
T Number
for Chemical
HPS (Watts) MH (Watts)
50, 70 100 150 175 250
Group D Atmospheres (continued)
n-butyl acetate 425 350 123 123 123 123 123
isobutyl acetate 421 350 123 123 123 123 123
sec-butyl alcohol 343 325 123 123 123 123 2
di-isobutylene 391 350 123 123 123 123 123
ethane 472 T1 123 123 123 123 123
ethanol (ethyl alcohol) 363 350 123 123 123 123 123
ethyl acetate 426 350 123 123 123 123 123
ethylene diamine (anhydrous) 385 350 123 123 123 123 123
ethylene dichloride 413 350 123 123 123 123 123
gasoline (56-60 octane) 280 T2A 123 123 123 123
heptanes 204 T3 123 2
hexanes 223 T2D 123 2
isoprene 395 350 123 123 123 123 123
isopropyl ether 443 350 123 123 123 123 123
mesityl oxide 344 325 123 123 123 123 2
methane (natural gas) 537 T1 123 123 123 123 123
methanol (methyl alcohol) 385 350 123 123 123 123 123
3-methyl-l-butanol (isoamyl alcohol) 350 350 123 123 123 123 123
methyl ethyl ketone 404 350 123 123 123 123 123
methyl isobutyl ketone 448 350 123 123 123 123 123
2-methyl-1-propanol (isobutyl alcohol) 415 350 123 123 123 123 123
2-methyl-1-propanol (tertiary butyl alcohol) 478 T1 123 123 123 123 123
petroleum naphtha 288 T2A 123 123 123 123
pyridine 482 T1 123 123 123 123 123
octanes 206 T3 123 2
pentanes 260 T2B 123 123 2 2
1-pentanol (amyl alcohol) 300 T2 123 123 123 123 2
propane 432 350 123 123 123 123 123
1-propanol (propyl alcohol) 412 350 123 123 123 123 123
2-propanol (isopropyl alcohol) 399 350 123 123 123 123 123
propylene 455 T1 123 123 123 123 123
styrene 490 T1 123 123 123 123 123
toluene 480 T1 123 123 123 123 123
vinyl acetate 402 350 123 123 123 123 123
vinyl chloride 472 T1 123 123 123 123 123
xylenes (o-xylene) 463 T1 123 123 123 123 123
* Where no xture is indicated suitable for the specic chemical, see catalog section G1.
A saturated hydrocarbon mixture. Also known by synonyms benzine, ligroin, petroleum, ether or naptha.
Ignition temperatures shown should be regarded as approximations only. Per NFPA Bulletin 325M, ignition temperatures may vary according to such factors as
vapor/air mixture, size and space where ignition may occur, rate and duration of heating, oxygen concentration and other materials present.
This classied area suitability chart is based on NEC requirements and Appleton and UL testing. However the ultimate decision on suitability of these xtures for
classied areas depends solely on the judgement of the owner, insurance company, inspector and/or authority having jurisdiction.
Mercmaster

II HID
Classified Area Suitability
Maximum Temperatures in C Obtained from Tests in a 40 C Ambient, Vertical Position, Lamp Base Up, as per NEC.
Effective September, 2008
Copyright 2008
PAGE 84
800-621-1506
www.appletonelec.com

F1-84
F
Mercmaster

II HID
Enclosed and Gasketed Fixtures: High Pressure Sodium 50 W, 70 W,
100 W and 150 W
High Power Factor (Min. P.F. 90%). Suitable for Use in Wet Locations.
Prismatic Glass Globe or Type V Closed Glass Refractor. Mogul Base Lamps.
Class I, Div. 2
Groups A,B,C,D
Class II, Div. 1 and 2
Groups E,F,G
Class III
UL 1598A, UL 844, Marine Type Electric
Fixtures Outside Type (Salt Water)
Type
Mounting
Lamp
Watts
Hub Size
(Inches)
Catalog Numbers
With Globe** With 8 Refractor With 12 Refractor
Pendant 50 3/4 LPAL5075 LPAL5075J LPAL5075R
One Hub,
Rigid or
Flexible
Mounting
1 LPAL5010 LPAL5010J LPAL5010R
70 3/4 LPAL7075* LPAL7075J* LPAL7075R*
1 LPAL7010* LPAL7010J* LPAL7010R*
100 3/4 LPAL1075* LPAL1075J* LPAL1075R*
1 LPAL1010* LPAL1010J* LPAL1010R*
150 3/4 LPAL1575* LPAL1575J* LPAL1575R*
With Globe,
Less Guard
With 8 Refractor
(NEMA V)
1 LPAL1510* LPAL1510J* LPAL1510R*
Ceiling 50 3/4 LPCL5075 LPCL5075J LPCL5075R
Five Hubs,
Four Close-Up
Plugs
1 LPCL5010 LPCL5010J LPCL5010R
70 3/4 LPCL7075* LPCL7075J* LPCL7075R*
1 LPCL7010* LPCL7010J* LPCL7010R*
100 3/4 LPCL1075* LPCL1075J* LPCL1075R*
1 LPCL1010* LPCL1010J* LPCL1010R*
150 3/4 LPCL1575* LPCL1575J* LPCL1575R*
With Globe,
Less Guard
With 8 Refractor
(NEMA V)
1 LPCL1510* LPCL1510J* LPCL1510R*
Wall 50 3/4 LPWBL5075 LPWBL5075J LPWBL5075R
Five Hubs,
Four Close-Up
Plugs
1 LPWBL5010 LPWBL5010J LPWBL5010R
70 3/4 LPWBL7075* LPWBL7075J* LPWBL7075R*
1 LPWBL7010* LPWBL7010J* LPWBL7010R*
100 3/4 LPWBL1075* LPWBL1075J* LPWBL1075R*
1 LPWBL1010* LPWBL1010J* LPWBL1010R*
150 3/4 LPWBL1575* LPWBL1575J* LPWBL1575R*
With Globe,
Less Guard
With 8 Refractor
(NEMA V)
1 LPWBL1510* LPWBL1510J* LPWBL1510R*
25 Stanchion 50 1-1/4 LPSL50125 LPSL50125J LPSL50125R
One Hub 1-1/2 LPSL50150 LPSL50150J LPSL50150R
70 1-1/4 LPSL70125* LPSL70125J* LPSL70125R*
1-1/2 LPSL70150* LPSL70150J* LPSL70150R*
100 1-1/4 LPSL10125* LPSL10125J* LPSL10125R*
1-1/2 LPSL10150* LPSL10150J* LPSL10150R*
150 1-1/4 LPSL15125* LPSL15125J* LPSL15125R*
With Globe,
Less Guard
With 8 Refractor
(NEMA V)
1-1/2 LPSL15150* LPSL15150J* LPSL15150R*
* Add voltage sufx -MT for 120, 208, 240 or 277 V; -480 for 480 V.
Add voltage sufx -MT for 120, 208, 240 or 277 V
**To order xture with guard, add sufx -G (before adding voltage sufx).
For specic Class I suitability of each xture listed, see F1-109.
For 175 W and 250 W xtures, use 12 refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 250 W xtures.
Furnished with 8 NEMA V refractor to order with NEMA I or III refractor, change J in the catalog number to J1 or J3.
Add voltage sufx -MTMED for Medium Bass, 100W (order as special).
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 85
F1-85
F
Type
Mounting
Lamp
Watts
Hub Size
(Inches)
Catalog Numbers
With Globe** With 8 Refractor With 12 Refractor
Pendant 100 3/4 LPAH1075* LPAH1075J* LPAH1075R*
One Hub,
Rigid or
Flexible
Mounting
1 LPAH1010* LPAH1010J* LPAH1010R*
175 3/4 LPAH1775* LPAH1775J* LPAH1775R*
1 LPAH1710* LPAH1710J* LPAH1710R*
250 3/4 LPAH2575* LPAH2575J* LPAH2575R*
1 LPAH2510* LPAH2510J* LPAH2510R*
With Globe,
Less Guard
With 8 Refractor
(NEMA V)
Ceiling 100 3/4 LPCH1775* LPCH1775J* LPCH1775R*
Five Hubs,
Four Close-Up
Plugs
1 LPCH1010* LPCH1010J* LPCH1010R*
175 3/4 LPCH1075* LPCH1075J* LPCH1075R*
1 LPCH1710* LPCH1710J* LPCH1710R*
250 3/4 LPCH2575* LPCH2575J* LPCH2575R*
1 LPCH2510* LPCH2510J* LPCH2510R*
With Globe,
Less Guard
With 8 Refractor
(NEMA V)
Wall 100 3/4 LPWBH1075* LPWBH1075J* LPWBH1075R*
Five Hubs,
Four Close-Up
Plugs
1 LPWBH1010* LPWBH1010J* LPWBH1010R*
175 3/4 LPWBH1775* LPWBH1775J* LPWBH1775R*
1 LPWBH1710* LPWBH1710J* LPWBH1710R*
250 3/4 LPWBH2575* LPWBH2575J* LPWBH2575R*
1 LPWBH2510* LPWBH2510J* LPWBH2510R*
With Globe,
Less Guard
With 8 Refractor
(NEMA V)
25 Stanchion 100 3/4 LPSH1075* LPSH1075J* LPSH1075R*
One Hub 1 LPSH1010* LPSH1010J* LPSH1010R*
175 1-1/4 LPSH17125* LPSH17125J* LPSH17125R*
1-1/2 LPSH17150* LPSH17150J* LPSH17150R*
250 1-1/4 LPSH25125* LPSH25125J* LPSH25125R*
1-1/2 LPSH25150* LPSH25150J* LPSH25150R*
With Globe,
Less Guard
With 8 Refractor
(NEMA V)
* Add voltage sufx -MT for 120, 208, 240 or 277 V; -480 for 480 V.
**To order xture with guard, add sufx -G (before adding voltage sufx).
For specic Class I suitability of each xture listed, see F1-109.
For 175 W and 250 W xtures, use 12 refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 250 W xtures.
Furnished with 8 NEMA V refractor to order with NEMA I or III refractor, change J in the catalog number to J1 or J3.
Add voltage sufx -MTMED for Medium Bass, 100 W (order as special).
Mercmaster

II HID
Enclosed and Gasketed Fixtures: Metal Halide 175 W and 250 W
Constant Wattage (Min. P.F. 90%). Suitable for Use in Wet Locations.
Prismatic Glass Globe or Type V Closed Glass Refractor. Mogul Base Lamps.
Class I, Div. 2
Groups A,B,C,D
Class II, Div. 1 and 2
Groups E,F,G
Class III
UL 1598A, UL 844, Marine Type Electric
Fixtures Outside Type (Salt Water)
With Globe,
Less Guard
With 8 Refractor
(NEMA V)
With Globe,
Less Guard
With 8 Refractor
(NEMA V)
With Globe,
Less Guard
With 8 Refractor
(NEMA V)
With Globe,
Less Guard
With 8 Refractor
(NEMA V)
Effective September, 2008
Copyright 2008
PAGE 86
800-621-1506
www.appletonelec.com

F1-86
F
Mercmaster

II HID
Mounting Hoods and Ballast Bodies
Hoods and Ballast Housings are Copper-Free Aluminum (4/10 of 1%).
* MT (multi-volt) ballasts can be operated at an input voltage of either 120, 208, 240 or 277 V. 480 ballasts can be operated at input voltage of 480 V.
Mounting Hoods
Description
Hub Size
(Inches)
Catalog
Number
Pendant
One Hub,
Rigid or Flexible Mounting
3/4 LPA-75
1 LPA-100
Ceiling
Five Hubs,
Four Close-Up Plugs
3/4 LPC-75
1 LPC-100
Wall
Five Hubs,
Four Close-Up Plugs
3/4 LPWB-75
1 LPWB-100
25 Stanchion
One Hub 1-1/4 LPS-125
1-1/2 LPS-150
Mounting Adapter
Permits use of Mercmaster II pendant hood on existing V-51
and Mercmaster I mounting hoods. Remove Mercmaster I
ballast body from existing mounting hood, thread in adapter
and attach wire to Mercmaster II.
LPAD-1
Mercmaster II Ballast Bodies
Lamp
Watts
Ballast Body
Catalog Numbers Add Voltage Suffixes*
Type Globe/12 Refractor 8 Refractor 120V 208V 240V 277V 480V
High Pressure
Sodium
50 LPB50L LPBLH50R -MT -MT -MT -MT
70 LPB70L LPBLH70R -MT -MT -MT -MT -480
High Power Factor
(Min. P.F. 90%)
100 LPB100L LPBLH100R -MT -MT -MT -MT -480
150 LPB150L LPBLH150R -MT -MT -MT -MT -480
Metal Halide 100 LPB100H LPBH100R -MTMED -MTMED -MTMED -MTMED -480MED
Constant Wattage
(Min. P.F. 90%)
175 LPB175H LPBH175R -MT -MT -MT -MT -480
250 LPB250H LPBH250R -MT -MT -MT -MT -480
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 87
F1-87
F
Mercmaster

II HID
Globes, Guards, Gasket and Photocell
** Polycarbonate globes are shatter-resistant for use in processing plants, canneries, dairies, bakeries or anywhere broken glass would prove a hazard. Ideally
suited for areas where vandalism, high replacement and high maintenance costs are a problem. Do not use in ambients exceeding 25 C. For burning in verti-
cal base-up positions only.
Registered trademark of Thomas Manufacturing Corporation, Parkton, Md. It is recommended that guards be used with these globes.
Photocell
Description Catalog Number
Prismatic Glass Globes
Clear Heat-Resistant VPGL-2HR
Amber VPGL-2AM
Blue VPGL-2BL
Green VPGL-2GR
Red VPGL-2RE
Coated Prismatic Tuff-Skin


Glass Globes
For use in areas where xture is
subject to extreme thermal shock Clear Heat-Resistant VPGL-2HRT
Polycarbonate Globes Impact-Resistant**
Use 100W Lamp max.; do not
use in ambients exceeding 25 C
Clear VPGL-2PL
Amber VPGL-2AMPL
Green VPGL-2GRPL
Red VPGL-2REPL
Copper-Free Aluminum Guard KGU2
Replacement Gaskets Silicone Rubber
Globe & 12 Refractor Gasket VPGL-GK
8 Refractor Gasket KRF-GK
Photocell
For automatic dusk-to-dawn On-Off
control ts all mounting hoods (not
for use in hazardous locations)
120 Volt PC120
208 and 240 Volt PC248
277 Volt PC277
Gasket
Globe Guard
Polycarbonate
Globe
Coated Glass
Globe
Glass Globe
Effective September, 2008
Copyright 2008
PAGE 88
800-621-1506
www.appletonelec.com

F1-88
F
Mercmaster

II HID
Reflectors, Refractors and Guards
Screws furnished to Fasten Reflectors to Ballast Body.
Refractors Thread Directly into Ballast Body.
* 150 W max for HPS.
100 W max. for MH.
LPRG-2 LPBG-12
Polyester
Standard
Dome
30 Angle
Polyester
8 Refractor 12 Refractor
Description Catalog Number
Polyester Reectors
Standard Dome KR2-ST
30 Angle KR2-AN
Closed Prismatic Refractors 50W-250W*
8 Glass 12 Glass 12 Polycarbonate
(50-250 W*) (50-250 W*) (50-150 W)
NEMA I LPG-R1
NEMA II LPRF-2CG LPRF-2CP
NEMA III LPG-R3 LPRF-3CP
NEMA IV LPRF-4CP
NEMA V LPG-R5 LPRF-5CG LPRF-5CP
Steel Guards for 8 and 12 Refractors Above
3 machine screws furnished
Guard for 8 Refractor LPRG2
Guard for 12 Refractor LPBG12
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 89
F1-89
F
Mercmaster

II HID
Electrical Specifications and Fuse Kits for Field Installation
Fuses are filled with non-com-
bustible granular material per
NEC 501-6(5). Fuse Kit includes
fuse, fuse block, wire, mount-
ing screws and connectors. All
mounting hoods have provisions
for easy field installation of
fuses in fixtures.
Electrical Specifications
Line
Voltage
Type of
Ballast
Starting
Amps
Operating
Amps
Total
Watts
50-Watt High Pressure Sodium
120 HX-HPF 0.58 0.58 64
208 HX-HPF 0.35 0.33 64
240 HX-HPF 0.31 0.29 64
277 HX-HPF 0.25 0.25 64
480 HX-HPF
70-Watt High Pressure Sodium
120 HX-HPF 0.90 0.82 94
208 HX-HPF 0.50 0.48 94
240 HX-HPF 0.44 0.41 94
277 HX-HPF 0.35 0.36 94
480 HX-HPF 0.21 0.21 94
100-Watt High Pressure Sodium
120 HX-HPF 1.30 1.15 130
208 HX-HPF 0.76 0.67 130
240 HX-HPF 0.66 0.58 130
277 HX-HPF 0.60 0.50 130
480 HX-HPF 0.33 0.31 135
150-Watt High Pressure Sodium
120 HX-HPF 2.00 1.66 189
208 HX-HPF 1.16 0.96 189
240 HX-HPF 1.00 0.83 189
277 HX-HPF 0.88 0.75 189
480 HX-HPF 0.50 0.44 189
100-Watt Metal Halide
120 HX-HPF 1.20 1.15 130
208 HX-HPF 0.70 0.66 130
240 HX-HPF 0.61 0.58 130
277 HX-HPF 0.55 0.50 130
480 HX-HPF 0.30 0.35 140
Line
Voltage
Type of
Ballast
Starting
Amps
Operating
Amps
Total
Watts
175-Watt Metal Halide
120 C.W.A. 1.30 1.80 213
208 C.W.A. 0.75 1.10 213
240 C.W.A. 0.65 0.90 213
277 C.W.A. 0.55 0.80 213
480 C.W.A. 0.35 0.45 213
250-Watt Metal Halide
120 C.W.A. 1.20 2.60 295
208 C.W.A. 0.65 1.50 295
240 C.W.A. 0.60 1.30 295
277 C.W.A. 0.50 1.12 295
480 C.W.A. 0.30 0.65 298
Fuse Kit
Order fuses as a separate item by catalog number from right columns.
Lamp
Watts
Fuse Quantity
Required
Fuse Kit Catalog Number
Volts HPS MH
50 120 1 F5
208 2 F3
240 2 F3
277 1 F2
480
70 120 1 F5
208 2 F3
240 2 F3
277 1 F2
480 2 F2
100 120 1 F8 F6
208 2 F5 F4
240 2 F5 F3
277 1 F3 F3
480 2 F3 F2
150 120 1 F10
208 2 F5
240 2 F5
277 1 F5
480 2 F3
175 120 1 F5
208 2 F3
240 2 F3
277 1 F2
480 2 F2
250 120 1 F8
208 2 F5
240 2 F5
277 1 F3
480 2 F2
Effective September, 2008
Copyright 2008
PAGE 90
800-621-1506
www.appletonelec.com

F1-90
F
Mercmaster

II HID
Dimensions
Pendant Mount
25 Angle Stanchion
Mount
Wall Mount
Fixture with Guard and
Polyester Reflector
Fixture with 12
Refractor
Fixture with 8
Refractor
Ceiling Mount
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 91
F1-91
F
Mercmaster

II HID
Photometric Data
With 150-Watt High Pressure Sodium Lamp.
* Photometric data is based on fixtures with 150-watt
clear High Pressure Sodium lamp (16,000 lumen).
For candlepower values of fixtures with other HPS
lamps, use the following multipliers; for 100 W
(9,500 lumen) HPS lamp 0.594; for 70 W (6,400
lumen) HPS lamp 0.40; for 50 W (4,000 lumen)
HPS lamp 0.25. For candlepower values of fixture
with guard, multiply by 0.95.
Total Luminaire Efficiency = 86.1%
REPORT NUMBER: LP15LGG
150 W High Pressure Sodium fixture with Globe only*
CIE Type - Semi-Direct
Plane
Spacing
Criteria
0-180 2.82 Coefficients of Utilization - Zonal Cavity Method
90-270 2.82 Effective Floor Cavity Reflectance 0.20
Diagonal 2.82 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 95 95 95 95 89 89 89 89 77 77 77 67 67 67 57 57 57 53
0-10 50.74 1 81 74 69 64 75 69 64 59 59 55 51 50 47 44 42 39 37 33
10-20 164.55 2 71 62 54 47 65 57 50 44 49 43 38 41 36 32 33 30 27 23
20-30 310.47 3 64 52 44 37 58 48 41 34 41 35 30 34 29 25 28 24 20 17
30-40 611.05 4 57 45 36 30 53 42 34 28 35 29 24 29 24 20 24 19 16 13
40-50 961.13 5 52 40 31 24 48 37 29 23 31 24 19 26 20 16 21 16 13 10
50-60 1308.18 6 48 35 26 20 44 32 25 19 27 21 16 23 17 13 18 14 11 8
60-70 1542.35 7 44 31 23 17 40 29 21 16 24 18 14 20 15 11 16 12 9 7
70-80 1716.10 8 40 28 20 15 37 26 19 14 22 16 12 18 13 10 15 11 8 6
80-90 1799.18 9 38 25 18 13 35 24 17 12 20 14 10 17 12 8 14 10 7 5
90-100 1802.19 10 35 23 16 11 32 22 15 11 18 13 9 15 11 7 13 9 6 4
100-110 1676.86
110-120 1379.11 Zonal Lumen Summary
120-130 441.46 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 9.61 0-30 525.75 3.3 3.8 90-120 4858.16 30.4 35.3
140-150 3.33 0-40 1136.81 7.1 8.3 90-130 5299.62 33.1 38.5
150-160 0.74 0-60 3406.12 21.3 24.7 90-150 5312.56 33.2 38.5
160-170 0.00 0-90 8463.75 52.9 61.4 90-180 5313.30 33.2 38.6
170-180 0.00 0-180 13777.05 86.1 100.0
Total Luminaire Efficiency = 73.6%
REPORT NUMBER: LP15LST
150 W High Pressure Sodium fixture with Standard Dome Reflector*
CIE Type - Direct
Plane
Spacing
Criteria
0-180 1.46 Coefficients of Utilization - Zonal Cavity Method
90-270 1.46 Effective Floor Cavity Reflectance 0.20
Diagonal 1.68 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 88 88 88 88 86 86 86 86 82 82 82 78 78 78 75 75 75 73
0-10 266.98 1 79 76 72 69 77 74 71 68 71 68 66 68 66 64 65 64 62 60
10-20 799.41 2 71 65 59 55 69 63 58 54 61 57 53 58 55 52 56 53 50 49
20-30 1337.05 3 64 56 49 44 62 55 49 44 52 47 43 50 46 42 48 45 41 40
30-40 1732.06 4 58 49 42 36 57 48 41 36 46 40 36 44 39 35 42 38 35 33
40-50 2067.60 5 53 43 36 31 52 42 35 30 40 35 30 39 34 30 38 33 29 28
50-60 2317.60 6 49 38 31 26 47 38 31 26 36 30 26 35 30 25 34 29 25 24
60-70 2210.81 7 45 34 27 23 44 34 27 23 33 27 22 31 26 22 30 26 22 20
70-80 866.77 8 42 31 24 20 40 31 24 20 30 24 20 29 23 19 28 23 19 18
80-90 145.09 9 39 28 22 18 38 28 22 18 27 21 17 26 21 17 25 21 17 16
90-100 14.46 10 36 26 20 16 35 26 20 16 25 19 16 24 19 16 23 19 15 14
100-110 8.75
110-120 7.93 Zonal Lumen Summary
120-130 4.51 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 2.16 0-30 2403.44 15.0 20.4 90-120 31.14 0.2 0.3
140-150 0.48 0-40 4135.50 25.8 35.1 90-130 35.65 0.2 0.3
150-160 0.00 0-60 8520.70 53.3 72.3 90-150 38.29 0.2 0.3
160-170 0.00 0-90 11743.37 73.4 99.7 90-180 38.29 0.3 0.3
170-180 0.00 0-180 11781.65 73.6 100.0
Effective September, 2008
Copyright 2008
PAGE 92
800-621-1506
www.appletonelec.com

F1-92
F
Mercmaster

II HID
Photometric Data
With 150-Watt High Pressure Sodium Lamp.
* Photometric data is based on fixtures with 150-watt
clear High Pressure Sodium lamp (16,000 lumen).
For candlepower values of fixtures with other HPS
lamps, use the following multipliers; for 100 W
(9,500 lumen) HPS lamp 0.594; for 70 W (6,400
lumen) HPS lamp 0.40; for 50 W (4,000 lumen)
HPS lamp 0.25. For candlepower values of fixture
with guard, multiply by 0.95.
Total Luminaire Efficiency = 73.1%
REPORT NUMBER: LP15LAN
150 W High Pressure Sodium fixture with 30 Angle Dome Reflector*
CIE Type - Direct
Plane
Spacing
Criteria
0-180 2.06 Coefficients of Utilization - Zonal Cavity Method
90-270 1.58 Effective Floor Cavity Reflectance 0.20
Diagonal 1.62 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 86 86 86 86 84 84 84 84 79 79 79 75 75 75 71 71 71 70
0-10 222.62 1 76 71 67 63 73 69 65 62 65 62 59 62 59 57 58 56 54 52
10-20 664.60 2 68 60 54 49 65 58 53 48 55 50 46 52 48 45 49 46 43 41
20-30 1084.32 3 61 52 45 39 59 50 44 39 48 42 37 45 40 36 43 39 35 33
30-40 1536.55 4 55 45 38 32 53 44 37 32 42 36 31 39 34 30 37 33 29 27
40-50 1771.90 5 50 40 33 27 49 39 32 27 37 31 26 35 30 25 33 29 25 23
50-60 1771.51 6 46 36 28 23 45 35 28 23 33 27 22 31 26 22 30 25 21 20
60-70 1668.93 7 43 32 25 20 41 31 25 20 30 24 19 28 23 19 27 22 19 17
70-80 1422.36 8 40 29 22 18 38 28 22 17 27 21 17 26 21 17 25 20 16 15
80-90 994.54 9 37 26 20 16 36 26 20 16 25 19 15 24 19 15 23 18 15 13
90-100 432.23 10 35 24 18 14 33 24 18 14 23 17 14 22 17 13 21 16 13 12
100-110 104.58
110-120 20.99 Zonal Lumen Summary
120-130 1.21 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.04 0-30 1971.54 12.3 16.9 90-120 557.80 3.5 4.8
140-150 0.00 0-40 3508.09 21.9 30.0 90-130 559.01 3.5 4.8
150-160 0.00 0-60 7051.50 44.1 60.3 90-150 559.04 3.5 4.8
160-170 0.00 0-90 11137.33 69.6 95.2 90-180 559.04 3.5 4.8
170-180 0.00 0-180 11696.38 73.1 100.0
Total Luminaire Efficiency = 81.1%
REPORT NUMBER: LP15LJR5
150 W High Pressure Sodium fixture with
8 Prismatic Glass Reractor - NEMA Type V*
CIE Type - Semi-Direct
Plane
Spacing
Criteria
0-180 1.98 Coefficients of Utilization - Zonal Cavity Method
90-270 1.98 Effective Floor Cavity Reflectance 0.20
Diagonal 3.40 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 93 93 93 93 89 89 89 89 82 82 82 76 76 76 70 70 70 67
0-10 72.83 1 80 73 68 63 76 70 65 61 64 60 56 58 55 52 53 50 48 45
10-20 222.26 2 69 59 51 45 65 56 49 43 51 45 40 46 41 37 41 37 34 31
20-30 380.73 3 61 49 40 33 57 47 38 32 42 35 29 38 32 27 34 29 25 22
30-40 621.11 4 54 42 32 25 51 40 31 24 35 28 22 32 26 21 28 23 19 16
40-50 852.53 5 49 36 27 20 46 34 26 19 31 23 18 27 21 16 24 19 15 12
50-60 1765.29 6 45 32 23 16 42 30 22 16 27 20 14 24 18 13 21 16 12 10
60-70 3192.58 7 41 28 20 14 38 27 19 13 24 17 12 24 15 11 19 14 10 8
70-80 2366.61 8 38 25 17 12 36 24 16 11 22 15 10 19 14 9 17 12 8 6
80-90 1230.65 9 35 23 15 10 33 22 15 10 20 13 9 18 12 8 16 11 7 5
90-100 450.14 10 33 21 14 9 31 20 13 9 18 12 8 16 11 7 15 10 6 5
100-110 712.41
110-120 499.15 Zonal Lumen Summary
120-130 323.44 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 185.00 0-30 675.83 4.2 5.2 90-120 1661.70 10.4 12.8
140-150 81.31 0-40 1296.93 8.1 10.0 90-130 1985.14 12.4 15.3
150-160 21.08 0-60 3914.76 24.5 30.2 90-150 2251.45 14.1 15.3
160-170 2.81 0-90 10704.60 66.9 82.5 90-180 2275.34 14.2 17.5
170-180 0.00 0-180 12979.94 81.1 100.0
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 93
F1-93
F
Mercmaster

II HID
Photometric Data
With 175-Watt Metal Halide Lamp.
* Photometric data is based on fixtures with 175-
watt clear Metal Halide lamp (14,000 lumen). For
candlepower values of fixtures with other MH
lamps, use the following multipliers: for 250 W
(20,500 lumen) MH lamp 1.46; for 100 W (8,500
lumen) MH lamp 0.61. For candlepower values of
fixture with guard, multiply by 0.95.
Total Luminaire Efficiency = 75.41%
REPORT NUMBER: LP17HGG
175 W Metal Halide fixture with Globe only*
CIE Type - General Diffuse
Plane
Spacing
Criteria
0-180 n/a Coefficients of Utilization - Zonal Cavity Method
90-270 n/a Effective Floor Cavity Reflectance 0.20
Diagonal n/a % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 82 82 82 82 77 77 77 77 66 66 66 57 57 57 48 48 48 44
0-10 34.14 1 70 65 60 55 65 60 56 52 51 47 44 42 40 37 35 33 31 27
10-20 121.01 2 62 54 47 42 57 50 44 39 42 37 33 35 31 28 28 25 22 19
20-30 244.79 3 55 46 38 33 51 42 36 30 35 30 26 29 25 21 23 20 17 14
30-40 470.23 4 50 40 32 26 46 37 30 24 31 25 21 25 21 17 20 16 13 11
40-50 704.46 5 46 35 27 22 42 32 25 20 27 21 17 22 17 14 17 14 11 8
50-60 891.60 6 42 31 23 18 38 28 22 17 24 18 14 20 15 12 15 12 9 7
60-70 1045.37 7 38 27 20 15 35 25 19 14 21 16 12 18 13 10 14 10 8 6
70-80 1254.42 8 35 25 18 13 32 23 17 12 19 14 10 16 12 9 13 9 7 5
80-90 1376.19 9 33 22 16 12 30 21 15 11 17 13 9 14 10 7 12 8 6 4
90-100 1438.00 10 31 20 14 10 28 19 13 9 16 11 8 13 9 7 11 7 5 3
100-110 1400.16
110-120 1247.31 Zonal Lumen Summary
120-130 312.87 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 6.25 0-30 399.94 2.9 3.8 90-120 4085.47 29.2 38.7
140-150 2.55 0-40 870.17 6.2 8.2 90-130 4398.34 31.4 41.7
150-160 0.48 0-60 2466.24 17.6 23.4 90-150 4407.14 31.5 41.7
160-170 0.14 0-90 6142.22 43.9 58.2 90-180 4407.77 31.5 41.8
170-180 0.00 0-180 10549.99 75.4 100.0
Total Luminaire Efficiency = 63.8%
REPORT NUMBER: LP17HST
175 W Metal Halide fixture with Standard Dome Reflector*
CIE Type - Direct
Plane
Spacing
Criteria
0-180 1.50 Coefficients of Utilization - Zonal Cavity Method
90-270 1.50 Effective Floor Cavity Reflectance 0.20
Diagonal 1.66 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 76 76 76 76 74 74 74 74 71 71 71 68 68 68 65 65 65 64
0-10 217.38 1 69 66 63 61 67 65 62 60 62 60 58 59 57 56 57 55 54 53
10-20 654.00 2 62 57 52 48 61 56 51 48 53 50 47 51 48 46 49 47 45 43
20-30 1114.02 3 56 49 44 39 55 48 43 39 46 42 38 45 41 38 43 40 37 35
30-40 1399.97 4 51 43 37 33 50 42 37 33 41 36 32 39 35 32 38 34 31 30
40-50 1635.86 5 47 38 32 28 45 37 32 28 36 31 27 35 30 27 33 30 27 25
50-60 1697.00 6 43 34 28 24 42 33 28 24 32 27 23 31 27 23 30 26 23 22
60-70 1489.94 7 40 31 25 21 39 30 25 21 29 24 20 28 24 20 27 23 20 19
70-80 576.37 8 37 28 22 18 36 27 22 18 26 22 18 26 21 18 25 21 18 16
80-90 113.51 9 34 25 20 16 33 25 20 16 24 19 16 23 19 16 23 19 16 15
90-100 11.73 10 32 23 18 15 31 23 18 15 22 18 14 22 17 14 21 17 14 13
100-110 6.62
110-120 7.66 Zonal Lumen Summary
120-130 4.55 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 2.51 0-30 1985.40 14.2 22.2 90-120 26.01 0.2 0.3
140-150 1.74 0-40 3385.37 24.2 37.9 90-130 30.56 0.2 0.3
150-160 1.37 0-60 6718.24 48.0 75.2 90-150 34.81 0.2 0.3
160-170 1.36 0-90 8898.06 63.6 99.6 90-180 37.82 0.3 0.4
170-180 0.29 0-180 8935.88 63.8 100.0
Effective September, 2008
Copyright 2008
PAGE 94
800-621-1506
www.appletonelec.com

F1-94
F
Mercmaster

II HID
Photometric Data
With 175-Watt Metal Halide Lamp.
* Photometric data is based on fixtures with 175-
watt clear Metal Halide lamp (14,000 lumen). For
candlepower values of fixtures with other MH
lamps, use the following multipliers: for 250 W
(20,500 lumen) MH lamp 1.46; for 100 W (8,500
lumen) MH lamp 0.61. For candlepower values of
fixture with guard, multiply by 0.95.
Total Luminaire Efficiency = 61.6%
REPORT NUMBER: LP17HAN
175 W Metal Halide fixture with 30 Angle Dome Reflector*
CIE Type - Direct
Plane
Spacing
Criteria
0-180 2.02 Coefficients of Utilization - Zonal Cavity Method
90-270 1.62 Effective Floor Cavity Reflectance 0.20
Diagonal 1.58 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 73 73 73 73 71 71 71 71 67 67 67 64 64 64 61 61 61 59
0-10 176.81 1 64 61 57 54 62 59 56 53 56 53 51 53 51 49 50 49 47 45
10-20 539.59 2 58 52 46 42 56 50 45 42 47 44 40 45 42 39 43 40 38 36
20-30 889.43 3 52 45 39 34 50 43 38 34 41 36 33 39 35 32 37 34 31 29
30-40 1215.31 4 47 39 33 28 46 38 32 28 36 31 27 34 30 27 33 29 26 24
40-50 1357.71 5 43 34 28 24 42 34 28 24 32 27 23 30 26 23 29 25 22 21
50-60 1315.82 6 40 31 25 20 38 30 24 20 29 24 20 27 23 20 26 22 19 18
60-70 1166.27 7 37 28 22 18 35 27 22 18 26 21 17 25 20 17 24 20 17 15
70-80 999.07 8 34 25 20 16 33 25 19 16 24 19 15 23 18 15 22 18 15 14
80-90 651.96 9 32 23 18 14 31 23 17 14 22 17 14 21 17 13 20 16 13 12
90-100 224.27 10 30 21 16 13 29 21 16 12 20 15 12 19 15 12 18 15 12 11
100-110 70.03
110-120 13.33 Zonal Lumen Summary
120-130 1.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.05 0-30 1605.82 11.5 18.6 90-120 307.62 2.2 3.6
140-150 0.05 0-40 2821.13 20.2 32.7 90-130 308.62 2.2 3.6
150-160 0.00 0-60 5494.65 39.2 63.7 90-150 308.72 2.2 3.6
160-170 0.00 0-90 8311.95 59.4 96.4 90-180 308.72 2.2 3.6
170-180 0.00 0-180 8620.67 61.6 100.0
Total Luminaire Efficiency = 73.9%
REPORT NUMBER: LP17HJR5
175 W Metal Halide fixture with Globe and
8 Prismatic Glass Reractor - NEMA Type V*
CIE Type - Semi-Direct
Plane
Spacing
Criteria
0-180 2.08 Coefficients of Utilization - Zonal Cavity Method
90-270 2.08 Effective Floor Cavity Reflectance 0.20
Diagonal 3.78 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 85 85 85 85 82 82 82 82 75 75 75 69 69 69 64 64 64 61
0-10 46.88 1 72 66 61 56 68 63 58 54 57 54 50 52 49 46 47 45 43 40
10-20 143.90 2 62 53 46 39 59 51 44 38 46 40 35 41 36 32 37 33 30 27
20-30 253.40 3 55 44 35 29 51 41 34 28 37 31 25 33 28 23 30 25 21 19
30-40 435.19 4 49 37 28 22 46 35 27 21 31 24 19 28 22 17 25 20 16 13
40-50 581.59 5 44 32 23 17 41 30 22 16 27 20 15 24 18 14 21 16 12 10
50-60 1156.33 6 40 28 20 14 37 26 19 13 24 17 12 21 15 11 19 14 10 8
60-70 2929.07 7 37 25 17 12 34 23 16 11 21 15 10 19 13 9 17 12 8 6
70-80 1945.94 8 34 22 15 10 32 21 14 9 19 13 8 17 12 8 15 10 7 5
80-90 1081.31 9 31 20 13 8 30 19 13 8 17 11 7 16 10 7 14 9 6 4
90-100 382.24 10 29 18 12 7 28 18 11 7 16 10 6 14 9 6 13 8 5 4
100-110 573.81
110-120 379.25 Zonal Lumen Summary
120-130 234.75 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 130.46 0-30 444.18 3.2 4.3 90-120 1335.30 9.5 12.9
140-150 56.32 0-40 879.37 6.3 8.5 90-130 1570.05 11.2 15.2
150-160 14.79 0-60 2617.28 18.7 25.3 90-150 1756.84 12.5 15.2
160-170 2.06 0-90 8573.60 61.2 82.9 90-180 1773.68 12.7 17.1
170-180 0.00 0-180 10347.28 73.9 100.0
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 95
F1-95
F
Mercmaster

II HID
Isofootcandle Data
Footcandle Chart
(Initial Horiz. FTC)
Mercmaster II
No Reflector
No Guard
High Pressure Sodium
70 Watt 5,800 Lumen
100 Watt 9,500 Lumen
150 Watt 16,000 Lumen
Mercmaster II
With Reflector
No Guard
High Pressure Sodium
70 Watt 5,800 Lumen
100 Watt 9,500 Lumen
150 Watt 16,000 Lumen
Footcandle Chart
(Initial Horiz. FTC)
Mounting Height
(Ft.)
Horizontal Distance from Mounting Point (Ft.)
Lamp 0 5 10 15 20 25 30 35 40 45 50
70 watt 8 .60 2.70 1.50 .73 .38 .21 .13 .08 .06 .04 .03
HPS 10 .39 1.70 1.30 .72 .40 .24 .15 .10 .07 .05 .04
12 .27 1.10 1.10 .68 .41 .26 .17 .11 .08 .06 .04
15 .17 .66 .81 .60 .39 .26 .18 .13 .09 .07 .05
20 .10 .37 .43 .40 .33 .25 .18 .13 .10 .08 .06
100 watt 8 1.00 4.80 2.70 1.20 .62 .35 .21 .14 .10 .07 .05
HPS 10 .64 2.80 2.20 1.30 .67 .40 .25 .16 .11 .08 .06
12 .44 1.80 1.80 1.30 .71 .42 .28 .18 .13 .09 .07
15 .28 1.10 1.30 .97 .70 .45 .30 .21 .15 .11 .08
20 .16 .59 .69 .70 .55 .42 .32 .23 .17 .13 .10
150 watt 8 2.50 8.30 4.60 2.20 1.10 .62 .38 .25 .17 .12 .09
HPS 10 1.60 5.40 4.00 2.20 1.20 .71 .44 .29 .20 .14 .11
12 1.10 4.20 3.30 2.00 1.20 .76 .49 .33 .23 .17 .12
15 .72 2.10 2.40 1.80 1.20 .79 .54 .38 .27 .20 .15
20 .40 1.10 1.30 1.30 1.00 .73 .54 .40 .30 .23 .18

Mounting Height
(Ft.)
Horizontal Distance from Mounting Point (Ft.)
Lamp 0 5 10 15 20 25 30 35 40 45 50
70 watt 8 14.80 10.00 3.80 1.50 .55 .15 .05 .03 .02 .01 .01
HPS 10 9.50 7.70 3.70 1.60 .74 .32 .12 .05 .03 .02 .01
12 6.60 6.60 3.30 1.50 .87 .46 .18 .10 .05 .02 .02
15 4.20 4.20 2.70 1.70 .94 .56 .33 .18 .10 .06 .03
20 2.40 2.50 1.90 1.30 .92 .62 .41 .28 .18 .12 .08
100 watt 8 21.90 16.80 6.30 2.40 .86 .28 .08 .05 .03 .02 .01
HPS 10 14.00 12.40 6.00 2.70 1.20 .53 .19 .07 .04 .03 .02
12 9.70 9.40 5.50 2.80 1.40 .73 .36 .20 .13 .04 .03
15 6.20 6.70 4.40 2.70 1.60 .90 .53 .33 .19 .11 .05
20 3.50 4.30 3.10 2.20 1.50 1.0 .68 .44 .30 .21 .13
150 watt 8 36.90 27.80 10.50 3.80 1.30 .35 .14 .08 .04 .03 .02
HPS 10 23.60 20.80 10.10 4.40 2.00 .78 .29 .11 .07 .04 .03
12 16.40 15.80 9.20 4.60 2.20 1.20 .54 .30 .16 .06 .04
15 10.50 11.60 7.50 4.50 2.60 1.50 .86 .42 .26 .16 .08
20 5.90 7.20 5.20 3.70 2.50 1.70 1.10 .73 .50 .32 .19
Effective September, 2008
Copyright 2008
PAGE 96
800-621-1506
www.appletonelec.com

F1-96
F
Applications
Inexpensive HID integrally bal-
lasted fixture for use in hazardous
locations inexpensive to buy and
inexpensive to operate (uses one-
fifth as much electrical energy as
incandescent and three-quarters
as much as fluorescent).
Enclosed and gasketed HID lighting
fixtures for use in tunnels, walkways,
bridges, storage facilities, process-
ing plants, parking lots, foundries,
manufacturing plants, power plants
and other locations where moisture,
dirt, dust or corrosive atmospheres
are encountered.
Features
Wireless design. Threading of fix-
ture unit onto mounting hood makes
electrical connection. Only wiring
required is attaching two wires to
connection block in mounting hood.
Safe, easy servicing without discon-
necting any wiring. Wireless fixture
unit easily threads off mounting
hood for convenient servicing.
Quick, easy conversion from Apple-
ton V-51

incandescent installation
to Mercmaster Jr. HID. Just remove
V-51

fixture unit and thread Merc-


master Jr. fixture unit onto existing
V-51

mounting hood.
Choice of mounting hoods. Stan-
dard fixtures in pendant, ceiling,
outlet box, wall and stanchion
mountings. Additional mounting
hoods on page F1-131.
Standard pendant mounting hood
for rigid or flexible mounting. Bal-
anced round design automatically
hangs plumb when used with flex-
ible hanger.
Unitized construction reduces instal-
lation and maintenance costs.
Ballast has standard non-PCB bio-
degradable capacitors.
Medium base socket is furnished
with 200 C leads, prewired to the
ballast. Porcelain socket assures
trouble-free operation in high ambi-
ent installations.
Prismatic glass globe or glass
refractor is standard and threads
directly into fixture housing. Elimi-
nates glare and provides uniform
light distribution.
Fiberglass-reinforced polyester
reflector for exceptionally severe
corrosive atmospheres. Vented for
cooler, dirt-free operation, increased
lumen output.
Standard Materials
Mounting hoods: copper-free alu-
minum (4/10 of 1% max. copper
content) or malleable iron.
Ballast bodies: copper-free alumi-
num (4/10 of 1% max. copper con-
tent).
Guards: copper-free aluminum (4/10
of 1% max. copper content) or steel.
Reflectors: fiberglass reinforced
polyester or porcelain.
Globe: 35 W-100 W, threaded
prismatic glass and threaded poly-
carbonate; 150 W, threaded heat-
resistant prismatic glass.
Refractor: heat-resistant prismatic glass.
Standard Finishes
Ballast bodies, aluminum guard
and VMA, VXHA-A, OBVW1-A,
OBV1-A, JBW1-A, JB1-A, GSW2
and MS mounting hoods: epoxy
powder coat finish, electrostatically
applied for complete, uniform sur-
face protection.
VA, VXHA, OBVW1, OBV1, GS-2,
JBW1, and JB1 malleable iron
mounting hoods: triple coat (1)
zinc electroplate; (2) dichromate;
and (3) epoxy powder coat.
Steel guard: zinc electroplate.
Options
Fuses for fixtures. Factory installed.
Add suffix -F.
Compliances
UL Standard 1598A and UL 844
NEMA 4X
Marine Type Electric Fixture
Outside Type (Salt Water)
Mercmaster

Jr. HPS
Enclosed and Gasketed HPS Lighting Fixtures
High Pressure Sodium. Suitable for Use in Wet Locations.
UNILETS

for Use with Threaded Metal Conduit.


120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.
Conversion from Appleton V-51
incandescent installation to HID
Mercmaster Jr. is easy and fast.
Step No. 1: After power
is shut off, remove
present incandescent
V-51 fixture unit from
existing V-51 mounting
hood.
Step No. 2: Thread
Mercmaster Jr. HID
fixture unit onto
existing V-51
mounting hood
and conversion is
completed.
UL 1598A and 844

Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 97
F1-97
F
Mercmaster

Jr. HPS
Classified Area Suitability and Ballast Data
Thermal Suitability of Mercmaster Jr. Fixtures
Table at left below shows maximum
operating temperatures of Mercmaster
Jr. fixtures for Class I, Div. 2, in a 40
C ambient. Per NEC 500-2(c), the
temperature marking on fixtures shall
not exceed the ignition temperature
of the specific gas or vapor to be
encountered. NEC 500-2(b) states
that these markings (Identification
Numbers) marked on equipment
nameplates shall be in accordance
with Table 500-2(b). This NEC table
is duplicated, as it applies to Appleton
Mercmaster Jr. fixtures, in the table
below.
As shown, the higher the Temperature
Identification Number, the cooler the
fixture operates. Keep this in mind
when selecting a fixture for a specific
gas or vapor shown on pages 6 and 7.
EXAMPLE:

Gasoline (56-60 octane)
Fixture with Globe and Reflector
To determine Mercmaster Jr. thermal
suitability for the above example:
(1) Check pages F1-114 and F1-115
for ignition temperature of gas or
vapor to be encountered. Page F1-
115 reveals that 56-60 octane gaso-
line has an ignition temperature of
280 C.
(2) Look in table below for fixtures
under With Globe & Reflector that
do not exceed the 280 C ignition
temperature of the gasoline.
(3) Select the best fixture for your
purpose. The 35 W, 50 W, 70 W or
100 W fixture with globe and reflec-
tor is acceptable because none of
these fixture lamp surfaces exceed
the 280 C ignition temperature of
the gasoline.
Retrofits Incandescent Fixtures
Easily and Quickly
35 W HPS Comparable to 100/150 W Incandescent Lamp
50 W HPS Comparable to 200 W Incandescent Lamp
70 W HPS Comparable to 300 W Incandescent Lamp
100 W HPS Comparable to 1.5 300 W Incandescent Lamp
150 W HPS Comparable to 2.5 300 W Incandescent Lamp
Optional Factory-Installed Fuses Add Suffix -F
Available as a factory installed item with Mercmaster Jr.
fixtures.
Class I, Div. 2, Groups A, B, C and D Class II, Div. 1 & 2, Groups E, F and G
Temperature Identification Numbers of Mercmaster Jr. Fixtures Temperature Identification Numbers
Lamp
Watts
With Globe or with Globe & Reflector With 8 Refractor
Lamp
Watts
With Globe, with Globe & Reflector, or With 8 Refractor
UL/NEC Temp. Ident. No. UL/NEC Temp. Ident. No. UL/NEC Temp. Ident. No.
Nameplate
Marking
Temperature
Range (C)
Nameplate
Marking
Temperature
Range (C)
Nameplate
Marking
Temperature
Range (C) Groups
35 T4 121-135 T4 121-135 35 T4C 101-120 E, F, G
50 T2D 201-215 T3 181-200 50 T3C 136-160 E, F, G
70 T2B 231-260 T2C 216-230 70 T3B 161-165 E, F, G*
100 T2A 261-280 T2B 231-260 100 E, F, G**
150 T2 281-300 T2A 261-280 150
* 70W suitable for Groups E and F with globe; suitable for Groups E, F, and G with refractor.
** 100W suitable for Groups E, F and G with refractor only.
Ambient Suitability of Mercmaster Jr. Fixtures
35W 50W 70W 100W 150W
40 C 40 C 25 C 25 C 25 C
All fixtures suitable for operation at -40 F.
Electrical Specifications (Reactor Ballasts)
Lamp
Watts
Line Voltage
60 Hz
Line Current in Amperes
Input
Watts Starting HPF Operating HPF
35 120 0.41 0.38 43
50 120 0.62 0.56 60
70 120 0.70 0.73 82
100 120 1.10 1.00 115
150 120 1.70 1.50 170
These are guidelines only. Light distribution and other factors must be taken into consideration.
Effective September, 2008
Copyright 2008
PAGE 98
800-621-1506
www.appletonelec.com

F1-98
F
Mercmaster

Jr. HPS
35 W, 50 W, 70 W, 100 W, 150 W
UL Standards 1598A, 844, Marine Type Electric Fixtures Outside Type (Salt Water). NEMA 4A. Complete with
Mounting Hood. Medium Base Socket. High Power Factor (Min. P.F. 90%). Integral Ballast for 120 V Line Operation.
Enclosed and Gasketed Epoxy Clad.
With Globe:
35 W, 50 W:
Class I, Div. 2, Groups A,B,C,D
Class II, Div. 1 & 2, Groups E*,F,G
Class III
70 W:
Class I, Div. 2, Groups A,B,C,D
Class II, Div. 1 & 2, Groups E*,F
100 W, 150 W:
Class I, Div. 2, Groups A,B,C,D
With Refractor (NEMA V):
35 W, 50 W, 70 W, 100 W:
Class I, Div. 2, Groups A,B,C,D
Class II, Div. 1 & 2, Groups E*,F,G,
Class III
150 W:
Class I, Div. 2, Groups A,B,C,D
The MJBW Wall Mount Fixture is suitable for Class I, Div. 2, Groups A, B, C and D only.
UL Standard 1598A supersedes UL Standard 1572.
All fixtures on this page comply with UL Standard 844 except MJBW Wall Mount Fixture, which is not suitable for Class II, Div. 1.
Using cast outlet box (listed on page F1-126) with Wall Mount Fixture provides the following clearances: for the globe JBX box, 1-5/8 from wall; GSU
box, 2 from wall; for the refractor JBX box, 15/16 from wall; GSW box, 1-5/16 from wall. Reflectors cannot be used with the wall mount fixtures.
Stanchion Mount can be used with standard dome or 30angle reflector.
To order fixture with guard, add G before voltage (example: MA3575G-120).
* Per NEC 502-1, there is no such classification as Class II, Div. 2, Group E.
Type Mounting
Lamp
Watts
ANSI
Lamp
Type
Hub
Size
(Inches)
Catalog Number
With Globe,
Less Guard
With Refractor
(NEMA V)
Pendant 35 S76 3/4 MA3575-120 MA3575J-120
Aluminum mounting hood
and ballast body.
One Hub,
Rigid or Flexible Mounting
1 MA3510-120 MA3510J-120
50 S68 3/4 MA5075-120 MA5075J-120
1 MA5010-120 MA5010J-120
70 S62 3/4 MA7075-120 MA7075J-120
1 MA7010-120 MA7010J-120
100 S54 3/4 MA1075-120 MA1075J-120
1 MA1010-120 MA1010J-120
150 S55 3/4 MA1575-120 MA1575J-120
1 MA1510-120 MA1510J-120
Ceiling 35 S76 3/4 MC3575-120 MC3575J-120
Aluminum mounting hood
and ballast body.
Five Hubs,
Four Close-Up Plugs
1 MC3510-120 MC3510J-120
50 S68 3/4 MC5075-120 MC5075J-120
1 MC5010-120 MC5010J-120
70 S62 3/4 MC7075-120 MC7075J-120
1 MC7010-120 MC7010J-120
100 S54 3/4 MC1075-120 MC1075J-120
1 MC1010-120 MC1010J-120
150 S55 3/4 MC1575-120 MC1575J-120
1 MC1510-120 MC1510J-120
Wall 35 S76 MGSW35-120 MGSW35J-120
Malleable iron mounting hood and
aluminum ballast body. Fits GSU Cast
Boxes listed on page F1-132. Gasket
and screws furnished with xture.
50 S68 MGSW50-120 MGSW50J-120
70 S62 MGSW70-120 MGSW70J-120
100 S54 MGSW10-120 MGSW10J-120
150 S55 MGSW15-120 MGSW15J-120
Wall 35 S76 MJBW35-120 MJBW35J-120
Class I, Div. 2 only
Aluminum mounting hood and ballast
body. Fits JBX Cast Boxes listed on
page F1-132. Gasket and screws
furnished with xture.
50 S68 MJBW50-120 MJBW50J-120
70 S62 MJBW70-120 MJBW70J-120
100 S54 MJBW10-120 MJBW10J-120
150 S55 MJBW15-120 MJBW15J-120
25 Stanchion 35 S76 1-1/4 MS35125-120 MS35125J-120
Aluminum mounting hood
and ballast body.
One hub.
1-1/2 MS35150-120 MS35150J-120
50 S68 1-1/4 MS50125-120 MS50125J-120
1-1/2 MS50150-120 MS50150J-120
70 S62 1-1/2 MS70125-120 MS70125J-120
1-1/2 MS70150-120 MS70150J-120
100 S54 1-1/4 MS10125-120 MS10125J-120
1-1/2 MS10150-120 MS10150J-120
150 S55 1-1/4 MS15125-120 MS15125J-120
1-1/2 MS15150-120 MS15150J-120
With Globe,
Less Guard
With Refractor
(NEMA V)
With Globe,
Less Guard
With Refractor
(NEMA V)
With Globe,
Less Guard
With Refractor
(NEMA V)
With Globe,
Less Guard
With Refractor
(NEMA V)
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 99
F1-99
F
Mercmaster

Jr. HPS
Fixtures and Accessories
VMA
Order SEH box from catalog section A and octagonal box from Section OB. To order fixture with guard, add G before voltage (example: MOB35G-120).
Order JBX or GSU box on page F1-126.
Reflectors cannot be used with wall mount fixtures. See dimensions on page F1-127 for globe or refractor clearance from wall for these fixtures.
Stanchion mounting hood can be used with standard dome or 30angle reflector.
For other ceiling and wall mounting hoods, see catalog pages F2-18 and F2-19.
VA
VXHA
OBVW
GSW
JBW
OBV
GS
JB
MS
Lamp
Watts
ANSI Lamp
Type
Catalog Number
Type Mounting With Globe With 8 Refractor
Outlet Box Fixture
Aluminum ballast housing, complete with
aluminum mounting hood. Epoxy clad.
Use with SEH and 3-1/4 or 4 Octagonal
Outlet Box. Fixture furnished with
mounting plate and gasket. Octagonal
boxes not suitable for classied locations.
35 S76 MOB35-120 MOB35J-120
50 S68 MOB50-120 MOB50J-120
70 S62 MOB70-120 MOB70J-120
100 S54 MOB10-120 MOB10J-120
150 S55 MOB15-120 MOB15J-120
Catalog Number
Mounting Hoods for Use With Fixture Units on Page F1-126 Aluminum Malleable Iron
Pendant Mounting
Furnished with connection block, gasket and screws.
1/2 VA50
3/4 VMA75 VA75
1 VMA100 VA100
Ceiling Mounting Five Hubs
Furnished with connection block, gasket, screws and four
close-up plugs.
1/2 VXHA50-A VXHA50
3/4 VXHA75-A VXHA75
1 VXHA100-A VXHA100
Cast/Outlet Box Mounting
Fits SEH and 3-1/4 or 4 Octagonal Box
Furnished with connection block, mounting plate and gasket.
Octagonal outlet box not suitable for classied locations.
Wall OBVW1-A OBVW1
Ceiling OBV1-A OBV1
GS Round Base Fits GSU Cast Boxes
Furnished with connection block, gasket and screws.
Wall GSW2
Ceiling GS2
JB Round Base Fits JBX Cast Boxes
Furnished with connection block, gasket and screws.
Wall JBW1-A JBW1
Ceiling JB1-A JB1
Stanchion Mounting
25 Stanchion furnished with connection block and screws.
1-1/4 MS-125
1-1/2 MS-150
Effective September, 2008
Copyright 2008
PAGE 100
800-621-1506
www.appletonelec.com

F1-100
F
Mercmaster

Jr. HPS
Fixture Units and Accessories for Medium Base Lamps
V-51 reflectors cannot be used with Mercmaster Jr. Fixtures.
Do not use Polycarbonate Globes in ambients exceeding 25 C. These globes for burning in vertical base-up position only.
Using JBX Box with these fixtures and mounting hoods provides 15/16 clearance from wall with refractor and 1-5/8 clearance from wall with globe.
Using GSU Box with these fixtures and mounting hoods provides 1-5/16 clearance from wall with refractor and 2 clearance from wall with globe.
Fixture Unit
JRS-100
VPGL-GK
GSU-100 GSU-20
JBX
Ballast Body
Glass
Polycarbonate
Description
ANSI Lamp
Watts
Lamp
Type
Catalog
Number
Fixture Units
Ballast body with globe (VPGL-1 with 35 W, 50
W, 70W and 100W and VPGL-1HR with 150 W).
Use with mounting hoods on page F1-125 or any
V-51 series mounting hood. Polyester or porcelain
reector and aluminum guard are available. High
power factor (min. P.F. 90%). Ballast provides 120 V
line operation.
35 S76 MUL35-120
50 S68 MUL50-120
70 S62 MUL70-120
100 S54 MUL100-120
150 S55 MUL150-120
Ballast Bodies
Use with mounting hoods on page F1-125 or any
V-51 series mounting hood and with refractor or
globe listed. Order other accessories below as
desired. High power factor (min. P.F. 90%). Ballast
provides 120 V line operation.
35 S76 MBL35-120
50 S68 MBL50-120
70 S62 MBL70-120
100 S54 MBL100-120
150 S55 MBL150-120
Reectors 35 W-150 W Porcelain Polyester
Standard (porcelain, 16 dia.; polyester, 16-1/4 dia.) LPR-25ST LPRP-25ST
30 Angle (porcelain, 12 dia.; polyester, 14-3/8 dia.) LPR-25AN LPRP-25AN
Globes and Guard 35 W-150 W
Clear Heat-Resistant Prismatic Glass VPGL-1HR
Polycarbonate (100W lamp max.) VPGL-2PL
Copper-Free Aluminum Guard VPGU-1
Refractors and Guard 35 W-150 W
Closed Prismatic Glass 8 Refractors
NEMA V LPJR-5CG
NEMA II LPJR-2CG
Steel Guard for 8 Refractors LPBG-8
JBX Cast Conduit Outlet Boxes Size (Inches) Catalog Number
Aluminum. 1-5/16 inside depth. Four tapped
openings, two close-up plugs and mounting lugs.
Use with MJBW wall mount xture (page F1-124)
and JB round base mounting hoods (page F1-125)
1/2 JBX50L-A
3/4 JBX75L-A
GSU Cast Conduit Outlet Box (Form 20)
Malleable iron. 1-3/4 inside depth. Four 3/4 hubs
with four 3/4 to 1/2 reducers, and three 1/2
close-up plugs. Use with MGSW wall mount xture
(page F1-124 and GS round base mounting hoods
(page F1-125).
1/2 or 3/4 GSU-20
1 GSU-100
Replacement Socket 35 W-150 W (Medium Base) JRS-100
Replacement Globe Gasket, Silicone Rubber
35W-150W
VPGL-GK
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 101
F1-101
F
Mounting holes 9/32 diameter on 5-1/8 centers.
Mounting plate is a separate piece furnished with outlet box mount fixture. The 2.75 dimension is for mounting on 3-1/4 octagonal boxes and the 3.50
dimension is for 4 octagonal boxes.
Wall mount fixtures provide the following wall clearances: with GSU box 2 from wall with globe and 1-5/16 from wall with refractor; with JBX box 1-5/8
from wall with globe and 15/16 from wall with refractor. Reflectors cannot be used with wall mount fixtures.
Order GSU or JBX box separately.
Standard dome or 30angle reflectors can be used with stanchion mount.
Mercmaster

Jr. HPS
Dimensions: 35 W, 50 W, 70 W, 100 W and 150 W
MBL Ballast Body Fixture with 8 Refractor
Fixture with Guard and Polyester
Reflectors
GSW Wall Mount and
GS Ceiling Mount with GSU Box
JBW Wall Mount with JBX Box OBV Outlet Box Mount Stanchion Mount
VXHA Ceiling Mount VMA Pendant Mount
Effective September, 2008
Copyright 2008
PAGE 102
800-621-1506
www.appletonelec.com

F1-102
F
Mercmaster

Jr. HPS
Photometric Data for Medium Base Lamps
* Photometric data shown below is based on a High
Pressure Sodium, 100-watt, E-17 (9,500 lumens)
clear lamp. For candlepower values for 35 W HPS
lamp, use multiplier of 0.237 (2,250 lumens); for 50
W, 0.421 (4,000 lumens); for 70 W, 0.663 (6,300
lumens); for 150 W, 1.684 (16,000 lumens).
Total Luminaire Efficiency = 86.4%
REPORT NUMBER: MA10LG
100 W High Pressure Sodium fixture with Globe only*
CIE Type - General Diffuse
Plane
Spacing
Criteria
0-180 n/a Coefficients of Utilization - Zonal Cavity Method
90-270 n/a Effective Floor Cavity Reflectance 0.20
Diagonal n/a % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 94 94 94 94 88 88 88 88 75 75 75 64 64 64 54 54 54 49
0-10 4.85 1 78 71 65 59 72 66 60 55 55 50 46 45 41 38 36 33 31 26
10-20 43.17 2 69 59 51 44 63 54 47 40 45 39 34 36 31 27 28 25 21 17
20-30 122.87 3 62 50 41 34 56 46 38 31 38 31 26 30 25 21 23 19 16 12
30-40 226.99 4 56 43 34 27 51 39 31 25 32 26 21 26 21 16 20 16 12 9
40-50 382.62 5 51 38 29 22 46 35 26 20 28 22 17 23 17 13 17 13 10 7
50-60 611.21 6 46 33 25 19 42 31 23 17 25 19 14 20 15 11 16 11 8 5
60-70 792.47 7 43 30 22 16 39 27 20 14 23 16 12 18 13 9 14 10 7 4
70-80 928.84 8 39 27 19 14 36 25 17 12 20 14 10 16 11 8 13 9 6 3
80-90 1576.22 9 37 24 17 12 33 22 15 11 19 13 9 15 10 7 12 8 4 3
90-100 544.88 10 34 22 15 10 31 20 14 9 17 11 8 14 9 6 11 7 4 2
100-110 1057.02
110-120 922.15 Zonal Lumen Summary
120-130 653.04 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 289.45 0-30 170.89 1.8 2.1 90-120 2524.04 26.6 30.7
140-150 53.86 0-40 397.88 4.2 4.8 90-130 3177.09 33.4 38.7
150-160 3.01 0-60 1391.71 14.6 16.9 90-150 3520.39 37.1 38.7
160-170 0.00 0-90 4689.24 49.4 57.1 90-180 3523.41 37.1 42.9
170-180 0.00 0-180 8212.64 86.4 100.0
Total Luminaire Efficiency = 63.0%
REPORT NUMBER: MA10LST
100 W High Pressure Sodium fixture with Standard Dome Reflector*
CIE Type - Direct
Plane
Spacing
Criteria
0-180 1.62 Coefficients of Utilization - Zonal Cavity Method
90-270 1.62 Effective Floor Cavity Reflectance 0.20
Diagonal 1.86 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 75 75 75 75 73 73 73 73 70 70 70 67 67 67 64 64 64 62
0-10 28.80 1 66 63 59 56 64 61 58 55 58 55 53 55 53 51 53 51 50 48
10-20 230.31 2 59 52 47 42 57 51 46 42 48 44 41 46 43 40 44 41 38 37
20-30 526.86 3 52 44 38 33 51 43 37 33 41 36 32 39 35 31 37 34 30 29
30-40 779.26 4 47 38 31 26 45 37 31 26 35 30 26 34 29 25 32 28 25 23
40-50 920.48 5 43 33 26 22 41 32 26 21 31 25 21 29 25 21 28 24 20 19
50-60 1137.26 6 39 29 23 18 38 29 22 18 27 22 18 26 21 17 25 20 17 16
60-70 1249.17 7 36 26 20 15 34 25 19 15 24 19 15 23 18 15 22 18 15 13
70-80 826.95 8 33 23 17 13 32 23 17 13 22 17 13 21 16 13 20 16 13 11
80-90 218.59 9 31 21 15 11 30 21 15 11 20 15 11 19 14 11 18 14 11 10
90-100 0.00 10 28 19 14 10 28 19 14 10 18 13 10 17 13 10 17 13 10 8
100-110 0.00
110-120 5.66 Zonal Lumen Summary
120-130 33.20 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 28.53 0-30 785.98 8.3 13.1 90-120 5.66 0.1 0.1
140-150 3.17 0-40 1565.23 16.5 26.1 90-130 38.86 0.4 0.6
150-160 0.00 0-60 3622.97 38.1 60.5 90-150 70.55 0.7 0.6
160-170 0.00 0-90 5917.68 62.3 98.8 90-180 70.55 0.7 1.2
170-180 0.00 0-180 5988.23 63.0 100.0
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 103
F1-103
F
Total Luminaire Efficiency = 66.0%
REPORT NUMBER: MA10LAN
100 W High Pressure Sodium fixture with 30 Angle Dome Reflector
CIE Type - Direct
Plane
Spacing
Criteria
0-180 2.06 Coefficients of Utilization - Zonal Cavity Method
90-270 1.82 Effective Floor Cavity Reflectance 0.20
Diagonal 1.80 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 78 78 78 78 76 76 76 76 71 71 71 68 68 68 64 64 64 62
0-10 26.12 1 67 62 57 53 64 60 56 52 56 53 50 53 50 47 50 47 45 43
10-20 207.66 2 59 51 45 40 57 50 44 39 47 42 37 44 40 36 41 38 35 33
20-30 446.84 3 53 44 37 31 50 42 36 30 39 34 29 37 32 28 35 31 27 25
30-40 670.08 4 47 38 30 25 45 36 30 24 34 28 24 32 27 23 30 26 22 20
40-50 849.99 5 43 33 26 20 41 32 25 20 30 24 19 28 23 19 26 22 18 17
50-60 1010.15 6 39 29 22 17 38 28 22 17 26 21 16 25 20 16 23 19 15 14
60-70 1028.17 7 36 26 19 14 35 25 19 14 24 18 14 22 17 13 21 17 13 12
70-80 848.69 8 33 23 17 12 32 23 17 12 21 16 12 20 15 12 19 15 11 10
80-90 848.20 9 31 21 15 11 30 20 15 11 19 14 10 18 14 10 17 13 10 9
90-100 158.74 10 29 19 13 10 28 19 13 9 18 13 9 17 12 9 16 12 9 7
100-110 133.75
110-120 32.81 Zonal Lumen Summary
120-130 6.64 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.94 0-30 680.62 7.2 10.9 90-120 325.29 3.4 5.2
140-150 0.00 0-40 1350.70 14.2 21.5 90-130 331.93 3.5 5.3
150-160 0.00 0-60 3210.84 33.8 51.2 90-150 332.87 3.5 5.3
160-170 0.00 0-90 5935.91 62.5 94.7 90-180 332.87 3.5 5.3
170-180 0.00 0-180 6268.78 66.0 100.0
Total Luminaire Efficiency = 75.4%
REPORT NUMBER: MA10LN5
100 W High Pressure Sodium fixture with
8 Prismatic Glass Reractor - NEMA Type V
CIE Type - Semi-Direct
Plane
Spacing
Criteria
0-180 1.24 Coefficients of Utilization - Zonal Cavity Method
90-270 1.24 Effective Floor Cavity Reflectance 0.20
Diagonal 1.76 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 87 87 87 87 84 84 84 84 78 78 78 73 73 73 68 68 68 65
0-10 14.06 1 69 61 54 48 66 58 52 46 53 47 42 48 43 39 43 39 36 33
10-20 91.00 2 60 49 39 32 56 46 38 31 41 34 28 37 31 26 33 28 24 21
20-30 167.25 3 53 40 31 23 49 38 29 22 34 27 20 30 24 19 27 21 17 14
30-40 277.64 4 47 34 25 18 44 33 24 17 29 22 16 26 19 14 23 17 13 10
40-50 384.74 5 43 30 21 14 40 28 20 14 25 18 13 23 16 11 20 15 10 8
50-60 528.15 6 39 27 18 12 37 25 17 11 23 16 10 20 14 9 18 13 8 6
60-70 1000.19 7 36 24 16 10 34 23 15 10 20 14 9 18 12 8 16 11 7 5
70-80 1665.21 8 34 22 14 9 32 21 13 8 19 12 8 17 11 7 15 10 6 4
80-90 2087.90 9 32 20 12 7 30 19 12 7 17 11 7 15 10 6 14 9 5 4
90-100 277.09 10 29 18 11 7 28 17 11 6 16 10 6 14 9 5 13 8 5 3
100-110 322.50
110-120 161.07 Zonal Lumen Summary
120-130 93.90 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 52.86 0-30 272.32 2.9 3.8 90-120 760.66 8.0 10.6
140-150 27.10 0-40 549.96 5.8 7.7 90-130 854.56 9.0 11.9
150-160 10.68 0-60 1462.84 15.4 20.4 90-150 934.52 9.8 11.9
160-170 1.69 0-90 6216.15 65.4 86.8 90-180 946.89 10.0 13.2
170-180 0.00 0-180 7163.04 75.4 100.0
Mercmaster

Jr. HPS
Photometric Data for Medium Base Lamps
* Photometric data shown below is based on a High
Pressure Sodium, 100-watt, E-17 (9,500 lumens)
clear lamp. For candlepower values for 35 W HPS
lamp, use multiplier of 0.237 (2,250 lumens); for 50
W, 0.421 (4,000 lumens); for 70 W, 0.663 (6,300
lumens); for 150 W, 1.684 (16,000 lumens).
Effective September, 2008
Copyright 2008
PAGE 104
800-621-1506
www.appletonelec.com

F1-104
F
Mercmaster

Jr. HPS
Footcandle Data for Medium Base Lamps
No Reflector
No Guard
LAMP: High Pressure Sodium Medium Base,
Clear E-17
WATTS LUMENS
35 2,250
50 4,000
70 6,300
100 9,500
150 16,000
Standard
Polyester
Reflector
No Guard
LAMP: High Pressure Sodium Medium Base,
Clear E-17
WATTS LUMENS
35 2,250
50 4,000
70 6,300
100 9,500
150 16,000
Footcandle Chart (Initial Horizontal FTC)
Mounting
Height (FT)
Horizontal Distance from Mounting Point (Ft.)
Lamp 0 2 4 6 8 10 12 14 16 18 20 24 28 34 40
35 W 7 1.03 1.18 1.32 1.16 1.00 0.72 0.52 0.37 0.27 0.20 0.16 0.10 0.06 0.04 0.02
9 0.62 0.64 0.84 0.74 0.69 0.63 0.48 0.37 0.29 0.23 0.18 0.11 0.08 0.05 0.03
11 0.42 0.41 0.53 0.54 0.47 0.46 0.43 0.35 0.28 0.23 0.19 0.12 0.09 0.05 0.03
13 0.30 0.28 0.35 0.40 0.37 0.33 0.33 0.31 0.26 0.22 0.18 0.13 0.09 0.06 0.04
15 0.22 0.21 0.25 0.29 0.29 0.27 0.25 0.25 0.23 0.20 0.17 0.13 0.09 0.06 0.04
17 0.17 0.16 0.18 0.22 0.23 0.22 0.20 0.20 0.19 0.18 0.16 0.12 0.09 0.06 0.04
50 W 7 1.83 2.11 2.36 2.05 1.79 1.27 0.92 0.66 0.48 0.37 0.28 0.18 0.12 0.07 0.05
9 1.11 1.14 1.50 1.32 1.24 1.12 0.86 0.67 0.52 0.40 0.31 0.21 0.14 0.08 0.06
11 0.75 0.72 0.94 0.96 0.83 0.83 0.76 0.62 0.51 0.40 0.34 0.22 0.15 0.10 0.06
13 0.53 0.51 0.63 0.71 0.67 0.60 0.59 0.55 0.47 0.39 0.32 0.23 0.16 0.11 0.07
15 0.40 0.37 0.45 0.53 0.53 0.47 0.45 0.44 0.42 0.37 0.31 0.23 0.18 0.11 0.07
17 0.31 0.29 0.34 0.39 0.42 0.39 0.36 0.36 0.35 0.32 0.29 0.22 0.18 0.12 0.08
70 W 7 2.88 3.31 3.70 3.23 2.80 2.00 1.45 1.04 0.76 0.57 0.44 0.27 0.18 0.11 0.07
9 1.74 1.78 2.38 2.07 1.94 1.76 1.35 1.05 0.81 0.63 0.49 0.32 0.21 0.13 0.08
11 1.17 1.14 1.40 1.52 1.31 1.29 1.19 0.97 0.79 0.64 0.52 0.34 0.24 0.15 0.09
13 0.84 0.79 0.99 1.13 1.04 0.94 0.92 0.86 0.73 0.61 0.51 0.36 0.25 0.16 0.11
15 0.63 0.58 0.70 0.82 0.82 0.74 0.71 0.69 0.65 0.57 0.49 0.36 0.26 0.17 0.11
17 0.49 0.44 0.51 0.61 0.66 0.62 0.56 0.55 0.54 0.51 0.46 0.35 0.26 0.18 0.12
100 W 7 4.35 5.00 5.59 4.88 4.23 3.02 2.18 1.56 1.15 0.86 0.67 0.41 0.27 0.16 0.10
9 2.63 2.69 3.56 3.12 2.93 2.65 2.04 1.58 1.22 0.95 0.74 0.48 0.32 0.19 0.12
11 1.76 1.72 2.24 2.29 1.97 1.95 1.80 1.47 1.19 0.96 0.78 0.52 0.36 0.22 0.14
13 1.26 1.20 1.49 1.70 1.57 1.42 1.39 1.30 1.11 0.92 0.77 0.54 0.38 0.24 0.16
15 0.95 0.88 1.06 1.24 1.24 1.12 1.07 1.04 0.98 0.86 0.74 0.54 0.40 0.25 0.17
17 0.74 0.67 0.78 0.93 0.99 0.94 0.84 0.83 0.81 0.77 0.69 0.52 0.40 0.27 0.18
150 W 7 7.32 8.41 9.41 8.21 7.12 5.09 3.67 2.63 1.93 1.45 1.12 0.70 0.46 0.27 0.17
9 4.43 4.53 5.99 5.25 4.93 4.47 3.44 2.66 2.06 1.59 1.25 0.80 0.54 0.33 0.21
11 2.96 2.89 3.76 3.86 3.32 3.28 3.03 2.47 2.00 1.62 1.32 0.87 0.60 0.37 0.24
13 2.12 2.02 2.52 2.86 2.64 2.39 2.34 2.19 1.86 1.55 1.30 0.91 0.64 0.40 0.27
15 1.59 1.48 1.78 2.09 2.09 1.89 1.80 1.75 1.65 1.45 1.24 0.91 0.67 0.43 0.29
17 1.24 1.13 1.31 1.56 1.67 1.58 1.42 1.40 1.36 1.29 1.16 0.88 0.67 0.45 0.30
Footcandle Chart (Initial Horizontal FTC)
Mounting
Height (FT)
Horizontal Distance from Mounting Point (Ft.)
Lamp 0 2 4 6 8 10 12 14 16 18 20 24 28 34 40
35 W 7 5.93 5.61 4.78 2.76 1.88 1.25 0.83 0.55 0.37 0.22 0.13 0.05 0.02 0.01 0.01
9 3.59 3.30 3.49 2.29 1.60 1.19 0.86 0.63 0.46 0.33 0.25 0.11 0.05 0.02 0.01
11 2.40 2.22 2.32 2.02 1.32 1.04 0.82 0.63 0.49 0.37 0.29 0.17 0.09 0.04 0.02
13 1.72 1.61 1.64 1.63 1.25 0.89 0.73 0.60 0.48 0.39 0.31 0.20 0.13 0.06 0.02
15 1.29 1.22 1.21 1.26 1.10 0.83 0.64 0.54 0.45 0.38 0.31 0.21 0.14 0.08 0.04
17 1.01 0.95 0.93 0.97 0.94 0.78 0.58 0.49 0.42 0.36 0.30 0.22 0.15 0.09 0.05
50 W 7 10.53 9.96 8.48 4.90 3.34 2.21 1.48 0.98 0.66 0.39 0.24 0.10 0.05 0.02 0.02
9 6.38 5.86 6.19 4.07 2.84 2.12 1.54 1.11 0.82 0.60 0.44 0.20 0.10 0.04 0.02
11 4.27 3.95 4.12 3.58 2.34 1.86 1.46 1.12 0.86 0.67 0.52 0.31 0.16 0.07 0.04
13 3.06 2.86 2.91 2.91 2.22 1.59 1.31 1.07 0.85 0.69 0.54 0.36 0.24 0.11 0.05
15 2.30 2.16 2.15 2.23 1.96 1.47 1.15 0.96 0.82 0.67 0.55 0.38 0.26 0.15 0.07
17 1.79 1.68 1.66 1.72 1.67 1.39 1.03 0.87 0.75 0.64 0.54 0.39 0.28 0.16 0.11
70 W 7 16.60 15.69 13.37 7.71 5.25 3.48 2.33 1.54 1.03 0.61 0.37 0.15 0.07 0.02 0.01
9 10.04 9.22 9.75 6.42 4.48 3.33 2.42 1.75 1.28 0.93 0.69 0.31 0.15 0.06 0.02
11 6.72 6.22 6.49 5.64 3.68 2.92 2.29 1.76 1.36 1.05 0.81 0.49 0.26 0.10 0.05
13 4.81 4.50 4.57 4.57 3.50 2.50 2.05 1.67 1.34 1.08 0.86 0.56 0.36 0.16 0.07
15 3.62 3.40 3.39 3.51 3.09 2.31 1.81 1.52 1.27 1.05 0.87 0.59 0.41 0.23 0.11
17 2.82 2.66 2.60 2.71 2.64 2.19 1.23 1.37 1.17 1.00 0.85 0.61 0.43 0.26 0.15
100 W 7 25.04 23.66 20.17 11.63 7.92 5.26 3.51 2.32 1.56 0.92 0.56 0.23 0.10 0.03 0.02
9 15.15 13.91 14.71 9.68 6.75 5.62 3.65 2.65 1.93 1.41 1.05 0.47 0.22 0.09 0.03
11 10.14 9.38 9.79 8.50 5.55 4.40 3.45 2.66 2.05 1.58 1.22 0.74 0.39 0.15 0.07
13 7.26 6.79 6.90 6.89 5.28 3.77 3.09 2.52 2.02 1.63 1.30 0.84 0.55 0.25 0.11
15 5.45 5.13 5.12 5.30 4.66 3.49 2.73 2.29 1.92 1.59 1.31 0.89 0.61 0.35 0.17
17 4.25 4.01 3.93 4.09 3.98 3.30 2.46 2.06 1.77 1.51 1.28 0.91 0.65 0.39 0.23
150 W 7 42.17 39.84 33.97 19.58 13.34 8.85 5.91 3.91 2.62 1.56 0.94 0.39 0.18 0.06 0.03
9 25.51 23.42 24.77 16.31 11.37 8.45 6.14 4.45 3.26 2.37 1.76 0.79 0.37 0.14 0.06
11 17.08 15.80 16.49 14.32 9.35 7.44 5.81 4.48 3.45 2.66 2.05 1.24 0.66 0.25 0.12
13 12.23 11.43 11.62 11.60 8.89 6.36 5.21 4.24 3.41 2.74 2.19 1.41 0.92 0.42 0.19
15 9.18 8.63 8.62 8.92 7.84 5.87 4.59 3.86 3.23 2.68 2.21 1.51 1.03 0.59 0.29
17 7.15 6.75 6.61 6.88 6.70 5.56 4.13 3.47 2.97 2.54 2.16 1.54 1.10 0.66 0.39
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 105
F1-105
F
Mercmaster

Refractors
IES/NEMA Distribution Curves
NEMA Type I NEMA Type II
NEMA Type III
NEMA Type IV NEMA Type V
Effective September, 2008
Copyright 2008
PAGE 106
800-621-1506
www.appletonelec.com

F1-106
F
UL 1598A
Stylmaster

HID
Enclosed and Gasketed Fixtures for Use with HID Remote Ballasts
Copper-Free Aluminum Mounting Hoods. Porcelain Steel and Polyester Reflectors.
See Page F2-10 for dimensions.
3/4 Tapped opening furnished with 3/4 to 1/2 reducer for 1/2 stems.
Hub Size
(Inches)
Catalog Number
Description With Globe Globe and Guard Hood Only
Pendant
Rigid or Flexible Mounting
Mogul Base
for 50 W-150 W HPS,
and 175 W-250 W MH
1/2
3/4 VPAM2575 VPAM2575G VPAM75
Porcelain Steel and Polyester Reectors
For 50 W-150 W HPS,
and 175 W-250 W MH
Porcelain Polyester
Standard Dome LPR-25ST LPRP-25ST
30 Angle LPR-25AN LPRP-25AN
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 107
F1-107
F
Stylmaster

HID
Globes, Guards and Gasket
* Heat-resistant glass furnished as standard with 150 W HPS and 175 W and 250 W MH. Clear glass furnished as standard with 50 W-100 W HPS.
** Polycarbonate globes are shatter-resistant for use in processing plants, canneries, dairies, bakeries or anywhere broken glass would prove a hazard. Ide-
ally suited for areas where vandalism and high replacement and high maintenance costs are a problem. Do not use in ambients exceeding 25 C. For burn-
ing in vertical base up position only.
Registered Trademark of Thomas Manufacturing Corporation, Parkton, Md. It is recommended that guards be used with these globes.
Glass
Globe
Coated
Glass
Globe
Polycarbonate
Globe
Guard
Globe
Gasket
Socket
Item Description Catalog Number
Prismatic Glass Globes
For 50 W-150 W HPS,
and 175 W-250 W MH
Clear* VPGL-2
Clear Heat-Resistant* VPGL-2HR
Amber VPGL-2AM
Blue VPGL-2BL
Green VPGL-2GR
Red VPGL-2RE
Coated Tuff-Skin Glass Globes
For use in areas where
xture is subject to
extreme thermal shock
Clear Heat-Resistant VPGL-2HRT
Polycarbonate Globes Impact-Resistant**
Use 100-watt lamp max.
Do not use in ambients
exceeding 25 C
Clear VPGL-2PL
Amber VPGL-2AMPL
Green VPGL-2GRPL
Red VPGL-2REPL
Copper-Free Aluminum Guard
50 W-150 W HPS,
and 175 W-250 W MH VPGU-2
Replacement Porcelain Shock-Absorbing Socket
50 W-150 W HPS,
and 175 W-250 W MH (Mogul Base)
Pendant VPTS-2
Wall & Ceiling VPLR-25
Replacement Globe Gasket Silicone Rubber
50 W-150 W HPS, and 175 W-250 W MH VPGL-GK
Effective September, 2008
Copyright 2008
PAGE 108
800-621-1506
www.appletonelec.com

F1-108
F
Corroflood

250/400 Stainless Steel Floodlight


Integrally Ballasted Floodlights for 250 W or 400 W High Pressure Sodium or Metal Halide Mogul Base Lamps.
For Marine, Class I, Div. 2 Hazardous Locations and Corrosive Environments.
Applications
Powerful, efficient weatherproof
lighting for medium and large areas
such as chemical plants, refineries,
shipboard and marine industrial pro-
cess areas where severely corrosive
agents are present.
Features
Compact in size, rugged and
dependable.
Easy to install and service.
Integral ballast; choice of multi-tap
for 120, 208, 240, 277 or 480 volt.
Completely assembled fixture saves
installation time and cost.
Easily removable ballast tray.
Hinged door.
Seamless welded construction.
Can be mounted in any position
ranging from lens down to horizon-
tal, lens up.
Stainless steel latches to allow
relamping without tools.
Standard Materials
Fixture body and trunnion arm: 316
stainless steel.
16 gauge 316 stainless steel.
Lens: thermal-shock-resistant and
tempered impact-resistant glass.
Gasket: heavy-duty, high-tempera-
ture silicone rubber, firmly seated.
Socket: heavy-duty, mogul base
porcelain with heavy gauge brass,
nickel-plated, double lamp-grip
screw shell and spring-loaded cen-
ter contact.
Reflector: compound parabolic,
double segment, Alzak* finished
aluminum for optimum efficiency.
Compliances
UL Standard 1598A
UL Standard 844
Marine Type Electric Fixtures Out-
side Type (Salt Water)
NEMA 4X
* Alzak is a proprietary term of the Aluminum
Corporation of America.
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 109
F1-109
F
Corroflood

250/400 Stainless Steel Floodlight


Integrally Ballasted Floodlights for 250 W or 400 W High Pressure Sodium or Metal Halide Mogul Base Lamps.
For Marine, Class I, Div. 2 Hazardous Locations and Corrosive Environments.
UL Listed
Class I, Div. 2
Groups A,B,C,D
Suitable for Marine, Outdoor Salt Water
Location
UL 1598A, UL 844
NEMA 4X
Mounting Fittings and Accessories
Dimensions Description Cat. No. Dimensions Description Cat. No.
Pipe or Wall
Mount Bracket
Used with G-AM-8-CA. Clamps
to 1 to 2-1/2 pipe, vertical or
horizontal, or mounts on flat
surfaces. Includes U-bolt and
crossarm bracket bolts. Malleable
iron, zinc plated, chromate
sealed, with architectural bronze
POLYESTER finish.
G-AM-8-WB
Poletop Slip-Fitter
Slip-fits 1-1/2 or 2 pipe size
poletop tenons. Includes flood-
light yoke bolts, 3 locking bolts,
and cord grip. Body is mal-
leable iron-zinc plated, chromate
sealed, with cast aluminum
cap. Assembly has architectural
bronze POLYESTER finish.
G-SF20
Crossarm
Mounting Bracket
Has 180horizontal adjustment
degree marked. Facilitates mount-
ing floodlight to crossarm or other
flat surface, or to G-AM-8-WB.
Includes floodlight yoke bolts.
Malleable iron, zinc plated, chro-
mate sealed, architectural bronze
POLYESTER finish.
G-AM-8-CA
Poletop Slip-Fitter
Slip-Fits 2 or 2-1/2 poletop
tenons. Includes floodlight yoke
bolts, 3 locking bolts and cord
grip. Malleable iron, zinc plated,
chromate sealed, with architec-
tural bronze POLYESTER finish.
G-AM-8-SF
Ordering Information
Lamp Type Line Voltage
For Class I, Div. 2
Classified Duty and Marine
T Rating Yoke Mount Catalog Number*
High Pressure Sodium
400 W HPS 120-277 SSF771L-MT-I/2 350
400 W HPS 480 SSF771L-48-I/2 350
250 W HPS 120-277 SSF671L-MT-I/2 350
250 W HPS 480 SSF671L-48-I/2 350
Metal Halide
400 W MH 120-277 SSF771H-MT-I/2 350
400 W MH 480 SSF771H-48-I/2 350
250 W MH 120-277 SSF671H-MT-I/2 350
250 W MH 480 SSF671H-48-I/2 350
Ballast has primary taps for 120 V, 208 V, 240 V and 277 V.
* Quartz emergency lamp not available for Class I, Div. 2 xtures. Consult factory for emergency quartz for non-classied areas. Floodlights have 3/4 N.P.T.
tapped hub for power entry.
Effective September, 2008
Copyright 2008
PAGE 110
800-621-1506
www.appletonelec.com

F1-110
F
Corroflood

250/400 Stainless Steel Floodlight


Integrally Ballasted Floodlights for 250 W or 400 W High Pressure Sodium or Metal Halide Mogul Base Lamps.
For Marine, Class I, Div. 2 Hazardous Locations and Corrosive Environments.
.5
0
.5
1
2
1.5
2.5
D
i
s
t
a
n
c
e

i
n

t
e
r
m
s

o
f

m
o
u
n
t
i
n
g

h
e
i
g
h
t

0 .5 1.0 1.5 2.0


Distance in terms of mounting height
45
MH
F
E
A
B
C
D
(i.e. ratio of distance to height. Example:
@ 20 mounting height, 1 means 20; 2
means 40, etc.)
Photometric charts available on request.
Typical Footcandle Values
Mtg.
Ht.
Footcandles for Iso-Footcandle Lines
Mtg.
Ht.
Footcandles for Iso-Footcandle Lines
A B C D E F A B C D E F
400 W HPS 250 W HPS
60 3.27 2.74 1.82 0.92 0.37 0.18 60 1.96 1.64 1.09 0.55 0.22 0.11
50 4.74 4.00 2.90 1.37 0.52 0.27 50 2.84 2.40 1.74 0.82 0.31 0.16
40 7.65 6.28 4.38 2.27 0.82 0.43 40 4.58 3.76 2.62 1.36 0.49 0.26
30 13.10 10.92 7.83 3.47 1.45 0.77 30 7.85 6.54 4.69 2.08 0.87 0.46
20 28.22 25.55 17.37 7.28 3.46 1.82 20 16.90 15.30 10.40 4.36 2.07 1.09
400 W MH 250 W MH
60 2.32 1.66 1.00 0.58 0.33 0.17 60 1.40 1.00 0.60 0.35 0.20 0.10
50 3.32 2.32 1.49 0.76 0.48 0.25 50 2.00 1.40 0.90 0.46 0.29 0.15
40 5.48 3.62 2.32 1.33 0.75 0.36 40 3.30 2.18 1.40 0.80 0.45 0.22
30 9.79 7.80 3.98 2.16 1.33 0.68 30 5.90 4.70 2.40 1.30 0.80 0.41
20 17.26 14.60 9.30 5.31 3.15 1.49 20 10.40 8.80 5.60 3.20 1.90 0.90
Electrical Specifications (All ballasts are CWA type.)
Line
Volts
Starting
Amps
Operating
Amps
Total
Watts
Starting
Amps
Operating
Amps
Total
Watts
400W High Pressure Sodium 400W Metal Halide
120 3.10 3.90 465 3.25 4.00 458
208 1.80 2.25 465 1.90 2.30 458
240 1.60 1.95 465 1.65 2.00 458
277 1.35 1.70 465 1.40 1.75 458
480 0.80 1.00 465 0.85 1.00 465
250W High Pressure Sodium 250W Metal Halide
120 1.75 2.70 300 1.20 2.60 295
208 1.00 1.50 300 0.65 1.50 295
240 0.85 1.30 300 0.60 1.30 295
277 0.75 1.15 300 0.50 1.12 295
480 0.40 0.65 295 0.30 0.65 298
Effective September, 2008
Copyright 2008
800-621-1506
www.appletonelec.com

PAGE 111
F1-111
F
Hazardous Location Photocontrols
Factory-Sealed
Applications
Encapsulated photocontrol provides
automatic dusk-to-dawn lighting
control in Class I, Div. 2 locations.
Typical applications include walk-
ways, security areas and any other
outdoor lighting application.
For use with Mercmaster III Low
Profile, Mercmaster III, and Merc-
master III 400 Series Luminaires.
For remote mounting in FS Boxes.
Features
Factory-sealed design eliminates the
need for an explosionproof enclosure.
Can be easily installed in the field.
Solid state design for performance
and reliability.
Available for 120, 208, 240, or 277
volts.
35-400 W H.I.D. incandescent or
fluorescent, 50/60 HZ.
1000 V.A. Voltage/Ampere
Minimum time delay: 15 seconds to
eliminate nuisiance tripping.
Turns fixture on at 3 footcandles, off
at 8 footcandles.
Provided with (3) 18AWG stranded
leads 6 in length.
Will fit through standard 1/2
knockout.
Materials
Encapsulated with epoxy sealing
compound.
FS Cover: aluminum
Compliances
Class I, Div. 2, Groups A,B,C,D
UL Standards: 1604 Hazardous
(Classified) Locations
NEMA 4X
PCD2 Series Hazardous Location Photocontrol
For use in Class I, Div. 2, Groups A,B,C,D locations.
Class I, Div. 2,
Groups A,B,C,D
Maintains Class I, Div. 2
rating for Mercmaster III
Low Profile, Mercmaster III,
and Mercmaster III 400
Series Luminaires
NEMA 4X
Ordering Information
1.13
(2.87 cm)
0.69
(1.75 cm)
1.94
(4.92 cm)
1.19
(3.02 cm)
1.375
(3.49cm)
2.56
(6.50 cm)
Factory-installed Photocontrol
Suffix Designation* Voltage Range
PC120 120 V, 50/60 Hz
PC208 208 V, 50/60 Hz
PC240 240 V, 50/60 Hz
Mercmaster III wall mounting hood with
photocontrol installed shown PC277 277 V, 50/60 Hz
Add to fixture catalog after voltage; i.e.: KPWBL1075MTPC12.
Photocontrol in FS cover for use with FS/FD box (Section B)
Catalog Number Voltage Range
FSKA-PC120D2 120V, 50/60 Hz
FSKA-PC247D2 208-277V, 50/60 Hz
Supplied with two stainless steel screws.
For neoprene gasket, order catalog number FS-GKR-1N.
Photocontrol for field installation
Catalog Number Max. Current Voltage Range
PC120D2 8.3 A 120 V, 50/60 Hz
PC247D2 3.5 A 208-277 V, 50/60 Hz
Dimensions
Effective September, 2008
Copyright 2008
PAGE 112
800-621-1506
www.appletonelec.com

F1-112