Sie sind auf Seite 1von 6

Company Name

GCAS
J ob Title
Client
J ob No Sheet No Rev
Part
Ref
By Date Chd
File Date/Time
1
16-May-14
Print Time/Date: 16/05/2014 20:44 Print Run 1 of 6
STAAD.Pro - RC CP65 Version 1.7
Job Information
Engineer Checked Approved
Name:
Date: 16-May-14
Structure Type SPACE FRAME
Number of Nodes 2 Highest Node 2
Number of Elements 1 Highest Element 1
Number of Plates 0 Highest Plate 0
Number of Design Groups 1
Number of Design Slabs 0
Number of Load Cases 1
Number of Design Briefs 1
Included in this printout are data for:
Design Group Design Brief Design Code Members
G1: Design Group 1 B1: 1 CP65 Column M2
Design Group Summary - Design Group 1
Member Design Type Main Bars
Major Minor
Shear
Local z Local y
M2 Initial Column Ok Ok Ok Ok
Summary: the group is safe
Column Input Data
Eff. Length Factors Braced
Member Type Length
(m)
Major Minor Major Minor Cover
(cm)
Link
Size
M2 Column 10.000 1.00 1.00 Yes Yes 3.0 8
Column Main Reinforcement
Member L/C Axial
(kN)
Major
(kNm)
Minor
(kNm)
Design
Axis
As Req.
(mm
2
)
Total
Bars
As Prov.
(mm
2
)
M2 L1 -0.000 0.000 -0.000 Biaxl maj 8000 24T40 17593
Summary: the group is safe
Column Shear Reinforcement
Max Shear in local y Max Shear in local z
Member L/C Value
(kN)
Position
(m)
L/C Value
(kN)
Position
(m)
Asv Req.
(mm
2
)
Link
Size
Spacing
(cm)
M2 L1 10.000 10.000 L1 0.000 0.000 550 8 27.5
Summary: the group is safe
Company Name
GCAS
J ob Title
Client
J ob No Sheet No Rev
Part
Ref
By Date Chd
File Date/Time
2
16-May-14
Print Time/Date: 16/05/2014 20:44 Print Run 2 of 6
STAAD.Pro - RC CP65 Version 1.7
Members
Member Element Node
A
Node
B
Property Emt Length
(m)
O. Length
(m)
M2 1 2 1 2000 x 1000 10.000 10.000
Member 2 - Scheduled Bars
Bar
Mark
Type and
size
No. of
bars
Bar Length
(mm)
Shape
code
A
(mm)
B
(mm)
C
(mm)
D
(mm)
E/R
(mm)
01 T40 24 10000 20
02 T10 36 5900 61 940 1940
03 T10 36 4750 61 370 1940
04 T10 36 2575 97 100 510 1940
05 T10 36 4675 61 940 1330
06 T10 36 3425 61 940 705
07 T10 36 2075 97 100 1010 940
Company Name
GCAS
J ob Title
Client
J ob No Sheet No Rev
Part
Ref
By Date Chd
File Date/Time
3
16-May-14
Print Time/Date: 16/05/2014 20:44 Print Run 3 of 6
STAAD.Pro - RC CP65 Version 1.7
Member 2 - Detailed CP65 Design Requirements
Section Property: 2000 x 1000
Storey height =10.000 m
Rectangular section: Width =2000 mm Depth =1000 mm
Cover =30 mm
Member 2 - Detailed CP65 Main Reinforcement
Shear bars not designed. Depth of main reinforcement taken as cover +brief link size
Axial N =-0.00 kN
Major M, M
1
, =0.00 kNm 3.8.3.2
M
2
, =-0.00 kNm
Minor M, M
1
, =0.00 kNm
M
2
, =-0.00 kNm
Warning - Low compression stress. This member may be better designed as a beam.
Column Type: SHORT 3.8.1.3
Due to both major and minor moments being significant, treat as BIAXIAL
Design M
x
=0.00 kNm
Design M
y
=-0.00 kNm
M
x
/ h' > M
y
/b'
M
x
' =M
x
+|
h'
b'
M
y
=0.00 +1.00
940
1940
-0.00 =0.00 kNm 3.8.4.5 eq40
Area of steel required =8000.00 mm
2
Actual neutral axis depth in section, x =69.40 mm
Force produced by concrete stress block =2684.58 kN
Force produced by main steel =-2684.58 kN
internal forces =0.00 kN
Internal forces > axial N OK for axial resistance
Moment produced by concrete stress block =1260.74 kNm
Moment produced by main steel =1915.14 kNm
internal moments =3175.87 kNm
Internal moments > design moment OK for moment resistance
Min distance between bars =h
agg
+5 mm or bar diameter =40 mm 3.12.11.1
Smallest actual space between bars =107 mm
Max allowable spacing of bars in designed faces =
47000
f
s
s 300 =300 mm 3.12.11.2.4
Largest actual clear space between bars in designed faces =273 mm
Max allowable spacing of bars in other faces =155 mm Table 3.30
Largest actual clear space between bars in other faces =107 mm
Actual area of main reinforcement (24T40) =30159.29 mm
2
Company Name
GCAS
J ob Title
Client
J ob No Sheet No Rev
Part
Ref
By Date Chd
File Date/Time
4
16-May-14
Print Time/Date: 16/05/2014 20:44 Print Run 4 of 6
STAAD.Pro - RC CP65 Version 1.7
Member 2 - Detailed CP65 Main Reinforcement Cont...
Min area of compression reinforcement =0.4 % 3.12.5.3
Max area of reinforcement =6 % (8 % if horizontally cast)
3.12.6.2
Actual area of main reinforcement =1.51 %
Max area of reinforcement at laps =10 % 3.12.6.2
area by which steel can increase at laps =169840.71 mm
2
OK
Member 2 - Detailed CP65 Shear Reinforcement
Spacing provided, s
v
=275 mm
Major axis:
Shear force, V =10.00 kN
Moment, M =0.00 kNm
v =
V
b
v
d
=0.01 N/mm
2
3.4.5.2
<= 0.8 \ f
cu
and 5 N/mm
2
dimensions adequate
v
c
=0.84
|
\
100 A
s
b
v
d
|
|
.
1/3

|
\
400
d
|
|
.
1/4
/
m
=0.84 0.47
1/3
1.00
1/4
/ 1.25 =0.52 N/mm
2
3.4.5.4
f
cu
>30 v
c
=v
c
(f
cu
/ 30)
1/3
(f
cu
limited to 40) =0.57 N/mm
2
Table 3.8
v
c
' =v
c
+0.6
N
A
c

V h
M
=0.57 +0.6 -0.00 1.00 =0.57 N/mm
2
3.4.5.12
v s v
c
' only nominal links required 3.4.5.12
Area of links required =0.4 b
v
s
v
/ 0.87 f
yv
=549.73 mm
2
Area of links provided (7T10), A
sv
=549.78 mm
2
Minor axis:
Shear force, V =0.00 kN
Moment, M =0.00 kNm
v =
V
b
v
d
=0.00 N/mm
2
3.4.5.2
<= 0.8 \ f
cu
and 5 N/mm
2
dimensions adequate
v
c
=0.84
|
\
100 A
s
b
v
d
|
|
.
1/3

|
\
400
d
|
|
.
1/4
/
m
=0.84 0.45
1/3
1.00
1/4
/ 1.25 =0.52 N/mm
2
3.4.5.4
f
cu
>30 v
c
=v
c
(f
cu
/ 30)
1/3
(f
cu
limited to 40) =0.57 N/mm
2
Table 3.8
v
c
' =v
c
+0.6
N
A
c

V h
M
=0.57 +0.6 -0.00 1.00 =0.57 N/mm
2
3.4.5.12
v s v
c
' only nominal links required 3.4.5.12
Area of links required =0.4 b
v
s
v
/ 0.87 f
yv
=274.86 mm
2
Area of links provided (5T10), A
sv
=392.70 mm
2
Minimum size of link bars =10 mm 3.12.7.1
Actual size of link bars =10 mm
Maximum spacing of links =275 mm 3.4.5.5/3.12.7.1
OK
Company Name
GCAS
J ob Title
Client
J ob No Sheet No Rev
Part
Ref
By Date Chd
File Date/Time
5
16-May-14
Print Time/Date: 16/05/2014 20:44 Print Run 5 of 6
STAAD.Pro - RC CP65 Version 1.7
Design Group: Design Group 1 - Brief Detail: 1 CP65 Column
Group Data
Concrete grade C50 Min. Main Bar 12
Aggregate size 20 Max. Main Bar 40
Cover 30 Min. Shear Bar 8
Main Reinforcement
Main bars: T(460)
Shear Reinforcement
Shear bars: T(460)
Column Factors
Bracing conditions Eff. length factors
Braced y-y Yes y-y 1.00
Braced z-z Yes z-z 1.00
Slenderness K Calculated Starter bar area 804 mm
2
Member Loadcases Considered
L1: LOAD CASE 1
List of Design Groups - ConcCOL
Design Group Brief
G1 Design Group 1 1
List of Design Briefs - ConcCOL
Brief Code
1 1 CP65 Column
Company Name
GCAS
J ob Title
Client
J ob No Sheet No Rev
Part
Ref
By Date Chd
File Date/Time
6
16-May-14
Print Time/Date: 16/05/2014 20:44 Print Run 6 of 6
STAAD.Pro - RC CP65 Version 1.7
Brief Detail: 1 CP65 Column
Group Data
Concrete grade C50 Min. Main Bar 12
Aggregate size 20 Max. Main Bar 40
Cover 30 Min. Shear Bar 8
Main Reinforcement
Main bars: T(460)
Shear Reinforcement
Shear bars: T(460)
Column Factors
Bracing conditions Eff. length factors
Braced y-y Yes y-y 1.00
Braced z-z Yes z-z 1.00
Slenderness K Calculated Starter bar area 804 mm
2
Member Loadcases Considered
L1: LOAD CASE 1

Das könnte Ihnen auch gefallen