DATA SHEET FOR SYNCHRONOUS GENERATORS
DESIGN DATA
TAGS :
Purpose :
Quantity N. :
RATED POWER :
Rated voltage (Un) :
Shape :
Cooling
Air Water
Duty : Continuous
with lagging power factor :
Water type :
N. of poles :
system
Lubrication
Inlet pressure :
Max. loss of pressure :
Inlet temperature :
Max temperature stage :
Self-lubrication Independent forced lubrication
Execution
and degree
of protection
Enclosure :
Terminal boxes :
Instruments and auxiliaries :
GENERATOR
DATA
DRIVING
MACHINE
DATA
Type :
Coupling :
Axial thrust toward the motor :
Lube oil system for generator too :
Direct Gear
Baseplate : Common Not common
NOTES :
Frequency :
system
Fouling factor :
Neutral
point
Insulated
Earthed by resistance
Earthed
Indoor Outdoor
RATED POWER :
Brushless Static
Voltage regulated
Current compensate
Short circuit sustained
Voltage regulator range :
Speed responce :
With permanent magnet generator (PMG)
Reactive power regulated Power factor regulated
Regulation accuracy :
EXCITATION
Excitation
characte-
AND
CONTROL
SYSTEM
DATA
N. of phases :
Excitation
type
LOCATION
ELECTRIC
SYSTEM
DATA
Operational voltage (Ue) :
Max./min. short circuit power :
Frequency :
Coupling type :
ristics
This document is Company property. The Company lawfully reserves all rights.
Dept.
Agip
Sheet / of Compiled Date
Doc. n
/
COMPANY
Job.
AREA
COUNTRY
PLANT
Revision
0
INTERNAL NORMALIZATION

TAGS :
kVA
kPa
kPa C
I = mr kgm
kg
V % Hz
kW

% In for
%
sec.
%
+
sec.
%
MVA
% V Hz %
C




























































M
O
D
.
E
L
E
.
R
M
A
.
0
1
1
/
4
S
h
.
0
2
/
0
5
DATA SHEET FOR SYNCHRONOUS GENERATORS
This document is Company property. The Company lawfully reserves all rights.
Dept.
Agip
Sheet / of Compiled Date
Doc. n
/
COMPANY
Job.
AREA
COUNTRY
PLANT
Revision
0
INTERNAL NORMALIZATION

DESIGN DATA
TAGS :
NOTES :
Direct
CONNECTION
DETAILS
Through transformer
Reference diagram :
Through busways
Through cables
Isolate
In parallel with generators with external network
Normal
operation
Type :
Type :
Connection
to
network
Power
connection
VOLTAGE DROP APPLIED LOAD ACTUAL RUNNING LOAD
Cos phi kVA kVA Cos phi Max. transient %
Max. voltage variation for
application of steps of load
Transient
Short circuit
performances
WORKING
CONDITION
In case of bolted short circuit at the machine terminals, generatorshall supply a minimum
short circuit current of % of rated current for sec.
AUXILIARY
SUPPLY
Controls :
Signallings/Alarms :
EQUIPMENT
Space heaters
Star center C.T.
Voltage regulator
Excitation system
Lube oil system
Winding temperature detectors
Bearings temperature detectors
Fundation slabe and bolts
CONTROL AND TRIP DEVICES
Air filter working order
Cooling fluid circulation
Internal overpressure
ACCESSORY
AND
ANCILLARY
EQUIPMENT
Pos.
2.1
2.9
2.8
2.7
2.6
2.5
2.4
2.3
2.2
Pos.
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
CONTROL
PANELS
(NOTE 1)
Line and Start Point Panel
Ref. spc. N.
Ref. spc. N.
Ref. spc. N.
Generator Control Panel
Protection Relay - Tag
Ref. Data Sheet N.
Ref. Data Sheet N.
Ref. Data Sheet N.
- Tag
- Tag Installation
Installation
Installation
1) For Generators driven by Gas Turbine only.
-
-
-
Hz
Hz V
V
Vcc % kVA kV























































M
O
D
.
E
L
E
.
R
M
A
.
0
1
1
/
4
S
h
.
0
/
0
5
This document is Company property. The Company lawfully reserves all rights.
Dept.
Agip
Sheet / of Compiled Date
Doc. n
/
COMPANY
Job.
AREA
COUNTRY
PLANT
Revision
0
INTERNAL NORMALIZATION

DATA SHEET FOR SYNCHRONOUS GENERATORS
CONSTRUCTION DATA
TAGS :
MFR. and construction type :
Rated current :
Windings connection : Star Delta Terminals number :
Stator insulation class :
Overall noise level : dB(A) at 1 metre
D.E. :
N.D.E. :
Position (1) :
Connection : cable gland plate
Temperature rise :
NOTES :
BEARINGS
TYPE
POWER
TERMINAL
BOXES
Overspeed : R.P.M.:
Temperature rise : Rotor insulation class :
REACTANCE
subtransient (Td'') :
Type :
EXCITATION
AND
CONTROL
SYSTEM
Characteristics :
LUBRICANT
Grease Viscosity : Oil Type :
Quantity for first filling : Oil flow : hours Lubricating interval :
Inlet pressure :
AUXILIARIES
TERMINALS
star point terminal-box : line terminal-box :
1) Looking the generator from the coupling side (D.E.).
COSTANTS
TIME
Rotation (1) :
Maximum power output with one cooler out of service : % Rated power
Reactive power at cos phi = 0 e Un :
open circuit (Td ') :
o
under exciting over exciting
Short circuit ratio :
EFFICIENCY
NAL
CONVENTIO-
SUBTRANSIENT TRANSIENT
not saturated saturated saturated not saturated
DIRECT
COS PHI 4/4 LOAD 3/4 LOAD 1/2 LOAD
not saturated saturated
SYNCHRONOUS
VOLTAGE VARIATION ON FULL
LOAD AT NO LOAD CONDITION
WITH CONSTANT EXCITATION
AND SPEED
COS PHI DELTA V %
3

A
%
kg l/1'
kPa
sec
kVAR kVAR
% % % % % %






















































M
O
D
.
E
L
E
.
R
M
A
.
0
1
1
/
4
S
h
.
0
/
0
5
This document is Company property. The Company lawfully reserves all rights.
Dept.
Agip
Sheet / of Compiled Date
Doc. n
/
COMPANY
Job.
AREA
COUNTRY
PLANT
Revision
0
INTERNAL NORMALIZATION
4

DATA SHEET FOR SYNCHRONOUS GENERATORS
CONSTRUCTION DATA
TAGS :
Enclosure dimensions :
Axial thrust toward driven machine :
Masses :
Painting :
total kg rotor kg
colour cycle
kg
I= mr kgm
NOTES :
Quantity N.: Type : Position :
Quantity N.: Independent
Cooling water flow :
Position on generator frame :
COOLERS
m/1'
Lift mass : kg
FILTERS
Maximum dimensions : lenght width hight m m m
ACCESSORY AND ANCILLARY EQUIPMENT
CONSTRUCTION CHARACTERISTICS Q.ty Pos.




















































M
O
D
.
E
L
E
.
R
M
A
.
0
1
1
/
4
S
h
.
0
/
0
5
This document is Company property. The Company lawfully reserves all rights.
Dept.
Agip
Sheet / of Compiled Date
Doc. n
/
COMPANY
Job.
AREA
COUNTRY
PLANT
Revision
0
INTERNAL NORMALIZATION
5
DATA SHEET FOR SYNCHRONOUS GENERATORS

Tags :
Material description
Manufacturer
Quantity
min.required
Construction type and/or Code
Finishing paint
actual
2kg of each
colour per
SPARE PARTS REQUIRED FOR START-UP
NOTES :
Fuses of different types and
rated currents
Signalling lamps
Coloured caps for signalling
lamps, of different colours
Signalling lamps holders
with dropping resistance
and cap
Brushes
Auxiliary relays of the type and
manufacturer as those installed
Pushbuttons or control switch-
es of the two types most used
Control switches of the 2 types
most used in the switchboard
1 per type
0.050 N with
a minimum of 2
0.10 N with
a minimum of 2
0.10 N with
a minimum of 2
0.10 N with
a minimum of 3
1 per machine
1 per machine
1 per machine
each machine
N - Number of components of the same type installed.