BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS
SELECTION CHART AVAILABLE STANDARD MODELS BNS250... BNS33... BNS303... 1 No AES1102 (24VAC, 24VDC, 110VAC) AES1112 (24VAC, 24VDC, 110VAC) AES1135 (24VDC) AES1165 (24VDC) AES2285 SRB207AN-230V (48-240VAC) AES1337 (24VAC/DC) AES2335 (24-230V AC/DC) AES2135 (24-230V AC/DC) AES1265 (24VDC) AES1235 (24VDC) 1 1 (b) 2 No 1 1 (b) 1 No 1 1/3* (b/d)* 2 No 1 1/3* (b/d)* BNS250... BNS33... BNS303... BNS36 BNS260 BNS16-12Z BNS33-12Z(G)-2187 BNS-B20-12Z(G) BNS33S-12Z(G) 1 Yes 2 3 (d) 2 Yes 2 3 (d) 1 No 1 1/3* (b/d)* Automatic Automatic Automatic Automatic Automatic Automatic Automatic 1 Yes 3 3 (d) 1 Yes 3 4 (e) 6 Yes 2 Automatic SRB211AN (24VAC/DC) 1 Yes 2 Stop Cat. 0 1 Stop Cat. 1 4 (e) Automatic or Manual Automatic or Manual Automatic or Manual 3 (d) Safety Controller Suitable for use with Coded-Magnet Sensor Part Numbers below Max. Number of Directly- Connected BNS Series Sensors (without daisy chaining) Safety Controller Part Number (and available supply voltages) Number of Safety Outputs (Enabling Paths) Max. Achievable Safety Rating per EN 954-1 (ISO-13849-1) Feedback Circuit Type of Reset *Category 3 (Performance Level d) when safety controller is directly connect to load. 12Z(G) } 11Z(G) 11Z(G) 02Z(G) } } 5 148 Dimensions 22.5 x 100 x 121 mm PL c per EN ISO 13849-1, Control Category 1 to EN 954-1 1 enabling path Monitoring of 1 or a number of guard devices Connection of BNS .. -12z magnetic safety sensors with 1 NO and 2 NC contacts LED function indicators Available for various operational voltages Features Model Designation AES 1102-24VDC AES 1112-24VDC AES 1102-24VAC AES 1112-24VAC AES 1102-42VAC AES 1112-42VAC AES 1102-110VAC AES 1112-110VAC AES 1102-230VAC AES 1112-230VAC Approvals BG UL CSA AES 1102/AES 1112 BNS Compatible Controllers 149 AES 1102/AES 1112 Typical Application U 24 VDC Y E G N G N G N Y E Y E P K G Y G Y G Y P K P K B N W H W H W H B N B N e AES 1102 L1 A1 K1 K3 A2 K2 S14 C 13 S22 S32 14 K4 N 3 M Application Notes AES to secure a number of guard devices using series-parallel cir- cuits for PL c /Category 1 to EN ISO 13849-1, or Control Category 1 to EN 954-1. Only suitable for the connection of magnetic safety sensors. Monitoring a number of guard devices using BNS 33..-12z-2187 range magnetic safety sensors with isolated contacts. The wiring diagram is with guard devices closed and shows the de- energized condition. Use with multiple daisy-chained inputs does not permit identication of which guard/coded-magnet sen- sor is in an open/fault condition. Monitoring one guard device using a BNS .. -12z Series coded-magnet safety sensor. Typical Wiring Diagram 5 150 AES 1135/AES 1165 BNS Compatible Safety Controllers PL d per EN ISO 13849-1, Control Category 3 to EN 954-1 1 enabling circuit Enable delay time can be modied Monitoring of mechanical position switches, safety switches, solenoid interlocks, coded magnet sensors or E-stops Can be used as emergency-stop controller for Category 0 to EN 60204-1 Monitoring for short-circuit between connections with NO-NC contact combination Connection of input expansion modules possible Dimensions Model Designation Function Table Additional semi- conductor output Y Function of output Y Switching Condition Features 22.5 x 100 x 121 mm AES 1135-24VDC AES 1165-24VDC AES 1135 Y1 Enable Enable circuit closed Y2 No enable Enable circuit open Approvals BG UL CSA 151 AES 1135/AES 1165 Typical Applications AES to achieve up to PL d per EN ISO 13849-1, or Control Category 3 per EN 954-1. Monitoring a sliding, hinged or removable guard device using a solenoid interlock. The NC contact must have positive opening function when the guard device is opened. The wiring diagram is with guard device closed and shows the de-energized condition. Monitor 2 NC Contacts Jumper A1 (24 VDC) to X1 Extension of Enable Delay Time The enable delay time can be increased from 0.1 s to 1 s by changing the position of a jumper link connection under the cover of the unit. Application Notes Typical Wiring Diagram 5 152 AES 1235/AES 1265 BNS Compatible Safety Controllers PL d per EN ISO 13849-1, Control Category 3 to EN 954-1 2 enabling circuits Enable delay time can be modied Monitoring of mechanical position switches, safety switches, solenoid interlocks, coded magnet sensors or E-stops Contact combination can be changed from NO-NC to NC-NC Can be used as emergency-stop controller for Stop Category 0 to EN 60204-1 Monitoring for short-circuit between connections with NO-NC contact combination ISD Integral System Diagnostics 2 short-circuit proof additional transistor outputs Feedback circuit to monitor external relays Start function Operational voltage 24 VDC Connection of input expansion modules possible Additional contact by means of output expansion modules Dimensions ISD Features 22.5 x 100 x 121 mm The following faults are recognized by the safety controller and indicated by means of ISD Failure of door contacts to open or close Short-circuits on or between the switch connections Interruption of the switch connections Failure of the units internal safety relay to pull-in or drop-out Faults on the input circuits or on the relay control of the guard door monitor Model Designation Function Table Additional semi- conductor output Y Function of output Y Switching Condition AES 1235-24VDC AES 1265-24VDC AES 1235 Y1 Authorized operation Enabling paths closed Y2 No authorized operation Enabling paths open AES 1265 Y1 Authorized operation Enabling paths closed Y2 Fault Enabling paths open Approvals BG UL CSA AES 1235/AES 1265 AES 1235 AES 1236 14 L1 A1 100mA S13 K1 K3 A2 max. Y1 X1 K4 3 K2 S14 S21 S22 13 +24 VDC 0 V 0 V M 23 24 SK3 This model achieves PL d per EN ISO 13849-1, or Control Category 3 to EN 954-1. Monitoring a sliding, hinged or removable guard device, each using a coded magnet sensor A. The wiring diagram is with guard devices closed and shows the de- energized condition. Extension of Enable Delay Time The enable delay time can be increased from 0.1 s to 1 s by changing the position of a jumper link connection under the cover of the unit. Modication for 2 NC Contacts The safety motoring module can be modied to monitor two NC con- tacts by bridging terminals A1 and X2. The cross-wire monitoring between the connections then becomes inoperative. Start Pushbutton A start pushbutton (NO) can option- ally be connected to the inputs in the feedback circuit. With the guard device closed, the enabling circuits are then not closed until the start pushbutton has been operated. Feedback Circuit A feedback circuit is shown con- nected in the wiring diagram. If nei- ther a start push button nor feed- back circuit is used, input X1 must be connected to 24 VDC (A1). s Typical Applications Application Notes Typical Wiring Diagram 5 153 154 AES 2135 BNS Compatible Safety Controllers PL d per EN ISO 13849-1, Control Category 3 to EN 954-1 1 enabling circuit Enable delay time can be modied Monitoring of mechanical position switches, safety switches, solenoid interlocks, coded magnet sensors or E-stops Can be changed from NO-NC to NC-NC contact combination Can be used as emergency-stop controller for Category 0 to EN 60204-1 Monitoring for short-circuit between connections with NO-NC contact combination ISD Integral System Diagnostics Connection of input expansion modules possible 2 semiconductor auxiliary outputs (non- safety) Dimensions ISD Model Designation Features 45 x 100 x 121 mm The following faults are recognized by the safety controller and indicated by means of ISD Failure of door contacts to open or close Short-circuits on or between the switch connections Interruption of the switch connections Failure of the units internal safety relay to pull-in or drop-out Faults on the input circuits or on the relay control of the guard door monitor AES 2135 24-230V AC/DC Approvals BG UL CSA Function Table Additional semi- conductor output Y Function of output Y Switching Condition AES 2135 Y1 Enable Enable circuit closed Y2 No enable Enable circuit open AES 2135 AES to achieve PL d per EN ISO 13849-1, or Control Category 3 to EN 954-1. Monitoring a sliding, hinged or removable guard device, each using a safety coded magnet A. The wiring diagram is with guard devices closed and shows the de-energized condition. Extension of Enable Delay Time The enable delay time can be increased from 0.1 s to 1 s by jumping between the terminals X7 and X8. Modication for 2 NC Contacts The controller can be modied to monitor two normally closed con- tacts by jumping between the termi- nals X3 and X4. The short circuit monitoring between connections then becomes inoperative. Typical Applications Application Notes Typical Wiring Diagram 155 5 156 PL d per EN ISO 13849-1, Control Category 3 to EN 954-1 3 enabling circuits Enable delay time can be modied Monitoring of mechanical position switches, safety switches, solenoid interlocks, coded magnet sensors or E-stops NO-NC contact combination can be connected Can be used as emergency-stop controller for Category 0 to EN 60204-1 Monitoring for short-circuit between connections ISD Integral System Diagnostics Available for various operational voltages Short-circuit proof additional transistor outputs Feedback circuit to monitor external relays Start function Connection of input expansion modules possible Additional contact by means of output expansion modules Dimensions ISD Features 45 x 100 x 121 mm The following faults are recognized by the safety controller and indicated by means of ISD Failure of door contacts to open or close Short-circuits on or between the switch connections Interruption of the switch connections Failure of the units internal safety relay to pull-in or drop-out Faults on the input circuits or on the relay control of the guard door monitor Failure of or functional fault on the safety controller Model Designation Function Table Additional semi- conductor output Y Function of output Y Switching Condition AES 2335 24-230V AC/DC AES 2335 Y1 High (+24V) Enable circuit closed Y2 High (+24V) Enable circuit open Approvals BG UL CSA AES 2335 BNS Compatible Safety Controllers AES 2335 Typical Applications This model achieves PL d per EN ISO 13849-1, or Control Category 3 to EN 954-1. Monitoring a sliding, hinged or removable guard device. The wiring diagram is with guard device closed and shows the de- energized condition. neither a start push button nor feed- back circuit are connected, a jumper connection must be made between X1 and X2. Modication for 2 NC Contacts The controller can be modied to monitor two normally closed con- tacts by jumping between the terminals X3 and X4. The short circuit monitoring between connec- tions then becomes inoperative. Start Pushbutton A start pushbutton (NO) can option- ally be connected to the inputs in the feedback circuit. With the guard device closed, the enabling circuits are then not closed until the start pushbutton has been operated. Feedback Circuit For this purpose, the positive-drive contacts of the external contactors can be connected to input X1-X2. If s Application Notes Typical Wiring Diagram 157 5 158 AES 1337 BNS Compatible Safety Controllers Front View Description The above general-purpose safety controllers are designed for use with safety devices having Normally-Open (N.O.) or Normally-Closed (N.C.) outputs. Each is equipped for connection of one input device in dual-channel congu- ration. In addition they feature user-selectable monitored- manual or automatic reset, feedback monitoring of positive- guided controlled loads and cross-short recognition (on selected models). Input Voltage 24 VAC/DC # Discrete Input Devices 1 (Dual-Channel) Monitored Monitored Contact Conguration 1 N.O. 1 N.C. Number &Type Safety Outputs 3 N.O. (Dry Contacts) Number &Type Auxiliary 1 N.C. 24 VDC (Non-Safety or Signalling Output) Typical Input Devices Monitored E-stops (N.C.) Interlock switches (N.C.) Type of Reset Monitored-manual (24 VDC trailing edge) (Selectable) Automatic Feedback Monitoring Yes LED Displays Green LEDs for: K1 (safety relay 1) K2 (safety relay 2) Ui (voltage beyond internal fuse) Conformity to Standards UL, CSA, BG (CE-compliant) Stop Category 0 Safety Classication PL e per EN ISO 13849-1 Control Category 4 per EN 945-1 Type Fuse Hybrid Selected Features Cross-short recognition Selectable monitored- manual or automatic reset Feedback monitoring Model AES 1337 shown. TECHNICAL FEATURES AVAILABLE MODELS AES 1337 24 V AC/DC Model Number Operating Voltage AES 1337 159 Operating Voltage 24 VDC -15% / +20%, residual ripple max. 10% 24 VAC -15% / +10%, 50/60 Hz Power Consumption 2.4 W (max.), 3.8 VA Fuse (Input Power) 24 V Internal electronic (hybrid) Fuse F1, Tripping current > 0.6 A (Resets after interruption of supply voltage) Fuse (Safety Outputs) 6 A Slow-blow (Recommended) Switching Capacity 230 VAC, 6 A Resistive (Safety Outputs) (inductive with suitable surge supressor) Switching Capacity 24 VDC, 100mA (Auxiliary Contacts) Application Category AC 15 / DC 13, EN 60 947-5-1 Contact Type & Materials AgSnO, self cleaning, positive-guided Contact Resistance 100 mOhm (max. in new state) Air Clearance & DIN VDE 0110-1 (04.97), 4 kV/2 Creepage Distance Cable Connections Self-lifting, plug-in screw terminals for 13 to 20 AWG Stranded or multi-core with wire end ferrule Terminal Labeling DIN EN 50 005 / DIN 50 013 TYPICAL WIRING DIAGRAM AES 1337 Dimensions (W x H x D) 22.5mm x 100mm x 121mm (0.9" x 3.9" x 4.75") Ambient Operating -25C to +45C Temperature Range (-13F to +113F) Mechanical Life Expectancy 10 7 switching cycles Weight 230 gm Mounting DIN rail (35mm) MECHANICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS 5 160 Input Voltage 24 V AC/DC # Discrete Input Devices 1 (Dual-Channel) Monitored Compatible Input Device N.O./N.C (Dry Contacts) Contact Conguration Number &Type 3 N.O. (1 delayed : 1-30 sec.) Safety Outputs (dry contacts) Number &Type Auxiliary PNP (Non-Safety or Signalling Outputs) Typical Input Devices E-stops (N.C./N.O.) Monitored Interlock switches (N.C./N.O.) Type of Reset Monitored-manual (Selectable) (24 VDC trailing edge) Automatic Feedback Monitoring Yes LED Displays Green LEDs for: K1 (safety relay 1) K2 (safety relay 2) K3/4 (safety relay 3 & 4) Ui (voltage beyond internal fuse) UB (voltage at input terminals) Conformity to Standards UL, CSA, BG (CE-compliant) Stop Category 0 (2 safety outputs) 1 (1 safety output) Safety Classication PL e per EN ISO 13849-1 Control Category 4 per EN 945-1 Selected Features Plug-in screw terminals Cross-short recognition Stop category 0 & 1 safety outputs Selectable trailing edge or automatic reset Resetable electronic fuse Feedback monitoring Description The Model SRB 211 AN is a general purpose unit designed for use with safety devices having Normally-Open and Normally-Closed dry contact switching outputs. It is equipped for connection of one monitored input device in dual-channel conguration. In addition it features user- selectable monitored-manual or automatic reset, stop category 0 & 1 safety outputs, and feedback monitoring of positive-guided controlled loads. TECHNICAL FEATURES AVAILABLE MODELS SRB 211 AN 24 V AC/DC Model Number Operating Voltage SERIES SRB 211 AN BNS Compatible Safety Controllers 161 SERIES SRB 211 AN Operating Voltage 24 VDC -15% / +20%, residual ripple max. 10% 24 VAC -15% / +10%, 50/60 Hz Power Consumption 5.2 W, 7.2 VA (max.), plus signaling output Y1 Fuse (Input Power) Internal electronic Fuse F1, Tripping current > 1.5A (Resets approx. 1 second) Fuse (Safety Outputs) 4 A Slow-blow (Recommended) Switching Capacity 230 VAC, 4 A Resistive (Safety Outputs) (inductive with suitable suppressor circuit) Switching Capacity 24 VDC 100mA (Auxiliary Contacts) Application Category AC 15 / DC 13 : EN 60 947-5-1 Pick-up Delay 40 ms Drop-out Delay 50 ms Contact Type & AgSnOAgNi, self cleaning, positive-guided Materials Contact Resistance 100 mOhm (max. in new state) Air Clearance & DIN VDE 0110-1 (04.97), 4 kV/2 Creepage Distance Cable Connections Plug-in, self-lifting, screw terminals for 13 to 20 AWG Stranded or multi-core with wire end ferrule Terminal Labeling DIN EN 50 005 / DIN 50 013 TYPICAL WIRING DIAGRAM Dimensions (W x H x D) 22.5mm x 100mm x 121mm (0.9" x 3.9" x 4.75") Ambient Operating -25C to +45C Temperature Range (-13F to +113F) Mechanical Life Expectancy >10 7 switching cycles Weight 255 gm Mounting DIN rail MECHANICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS 5 162 TECHNICAL FEATURES Input Voltage See available models below # Discrete Input Devices 6 (Dual-Channel) Monitored Compatible Input Device N.O./N.C. (Dry Contacts) Contact Conguration Number &Type 2 N.O. (Dry Contacts) Safety Outputs Number &Type Auxiliary 6 - short circuit proof, PNP-type (Non-Safety or semiconductor Y1 - Y6 max 20mA Signalling Outputs) 1 - N.C. Auxiliary output Typical Input Devices Interlocks (N.O./N.C.) Monitored Limit switches (N.O./N.C.) Type of Reset Monitored-manual (trailing edge) (Selectable) Automatic Feedback Monitoring Yes LED Displays Green LEDs for: K1 (safety relay 1) K2 (safety relay 2) Ui (voltage beyond internal fuse) Conformity to Standards UL, CSA, BG (CE-compliant) Stop Category 0 Safety Classication PL d per EN ISO 13849-1 Control Category 3 per EN 945-1 Selected Features Plug-in screw terminals Cross-short recognition Up to 6 monitored devices Seven auxiliary outputs Selectable monitored-manual or automatic reset Front View AES 2285/SRB 207 Description The Model SRB 207 AN is a general purpose unit designed for use with safety devices having Normally- Open (N.O.) and Normally-Closed (N.C.) dry contacts. Each is equipped for connection with up to six input devices such as E-stop push button and BNS coded magnets. In addition it features user-selectable monitored- manual or automatic reset, six (non-safety) semiconductor outputs for signalling/annunciation, and two safety outputs. AES 2285/SRB 207 AN BNS Compatible Safety Controllers AVAILABLE MODELS AES 2285 24 VDC SRB 207 AN-230V 48 - 230 VAC Model Number Operating Input Voltage 163 Operating Voltage 24 VDC -15% / +20%, residual ripple max. 10% 48 VAC-240VAC, 50-60 Hz Power Consumption 3.0 W max. (For 24 VDC) Approx. 6.8 VA (For 230 VAC) (Plus signalling contacts Y1-Y6) Fuse (Input Power) 24 V Internal electronic Fuse F1, Tripping current > 1 A (Resets after approx. 1 second) 230 V Primary : Fuse (glass), tripping current > 1 A Secondary : Internal electronic fuse, tripping current > 0.12 A Fuse (Safety Outputs) 6 A Slow-blow (Recommended) Switching Capacity Y1-Y6: 24 VDC, 20mA (PNP) (Auxiliary Contacts) 31-32: 24 VDC, 2 A (Dry) Switching Capacity 230 VAC, 6 A Resistive (Safety Outputs) (inductive with suitable supressor circuit) Application Category AC-15 / DC-13 : EN 60 947-5-1 Pick-up Delay 120 ms/ 30ns (auto start/reset button) Drop-out Delay 20 ms Contact Type & Material AgSnO, self cleaning, positive-guided Contact Resistance 100 mOhm (max. in new state) Air Clearance & DIN VDE 0110-1 (04.97), 4 kV/2 Creepage Distance Cable Connections Self-lifting, plug-in screw terminals for 13 to 20 AWG Stranded or multi-core with wire end ferrule Terminal Labeling DIN EN 50 005 / DIN 50 013 TYPICAL WIRING DIAGRAM (shown with 1 input) AES 2285/SRB 207 AN Dimensions (W x H x D) 45mm x 100mm x 121mm (1.77" x 3.9" x 4.75") Ambient Operating -25C to +45C Temperature Range (-13F to +113F) Mechanical Life Expectancy >10 7 switching cycles Weight 300 gm Mounting DIN rail MECHANICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS 5 164 Safer by Design