Contents Relevant Process/Regulation ............................................................... 1 1 Abstract ............................................................................. 3 2 Purpose .............................................................................. 3 Operating Instructions ................................................................... 4 2.1 Link Balance Equations: .......................................................... 4 2.2 Counters used for path-balance Judgment .......................................... 4 2.3 Judgment Criteria ................................................................ 6 2.4 Normal Trend for Path-Balance .................................................... 6 2.5 Weak DL Trend for Path-Balance ................................................... 7 2.6 Weak UL Trend for Path-Balance ................................................... 8 2.7 Misleading Case for Path-Balance ................................................. 9 3 Appendix ............................................................................ 10 4 Support Document(s) ................................................................. 10 5 Related Document(s) ................................................................. 10 6 Record Retention .................................................................... 10 7 Document Preparation/Modification Record ............................................ 10
TRX Path-Balance Check Confidentiality:
2012-03-13 Huawei Confidential Page 3 of 10
1 Abstract This document instructs engineers how to perform the Base Band Hopping audit. 2 Purpose This document aims to standardize the operation procedure of Path-Balance Judgment 1. Link balance Equations 2. Counters used for path-balance Judgment 3. Judgment Criteria 4. Normal Balance Trend 5. Weak UL Trend 6. Weak DL Trend 7. Misleading Case
TRX Path-Balance Check Confidentiality:
2012-03-13 Huawei Confidential Page 4 of 10
Operating Instructions 2.1 Link Balance Equations: UL/DL Path balance difference = UL path loss - DL path loss = (MS real transmit power-UL Rx_Lev) - (BTS cabinet output power-DL Rx_Lev). BTS cabinet output power=TRX power-static power class*2 + Power fine tuning - Combiner loss - DL dynamic PC level*2 + dynamic PBT gain 2.2 Counters used for path-balance Judgment The below counters define the balance status of the TRX into 11 levels and the balance should be around level 6 The levels below level 6 indicates the status of the UL The levels above level 6 indicates the status of the DL Level 1 Indicates that the UL > DL by 15 Level 1 Indicates that the DL > UL by 15
TRX Path-Balance Check Confidentiality:
2012-03-13 Huawei Confidential Page 5 of 10
BSC 6900 TRX Level Balance Counters UL/DL Path-balance Diffrence Comment S462A:Number of MRs (Uplink-and-Downlink Balance Level = 1)(none) X <= -15 UL > DL S462B:Number of MRs (Uplink-and-Downlink Balance Level = 2)(none) -14 < x < -11 UL > DL S462C:Number of MRs (Uplink-and-Downlink Balance Level = 3)(none) -10 < x < -8 UL > DL S462D:Number of MRs (Uplink-and-Downlink Balance Level = 4)(none) -7 < x < -5 UL > DL S462E:Number of MRs (Uplink-and-Downlink Balance Level = 5)(none) -4 < x < -2 UL > DL S462F:Number of MRs (Uplink-and-Downlink Balance Level = 6)(none) -1 < x < 1 Balance S462G:Number of MRs (Uplink-and-Downlink Balance Level = 7)(none) 2 < x < 4 DL > UL S462H:Number of MRs (Uplink-and-Downlink Balance Level = 8)(none) 5 < x < 7 DL > UL S462I:Number of MRs (Uplink-and-Downlink Balance Level = 9)(none) 8 < x < 10 DL > UL S462J:Number of MRs (Uplink-and-Downlink Balance Level = 10)(none) 11 < x < 14 DL > UL S462K:Number of MRs (Uplink-and-Downlink Balance Level = 11)(none) X => 15 DL > UL
TRX Path-Balance Check Confidentiality:
2012-03-13 Huawei Confidential Page 6 of 10
2.3 Judgment Criteria The criteria used to judge if the TRX is Balance or not is as following:
1- `Shape of the graph should be centered on Level 6 2- Sum of Levels (1 + 2) should be Less Than 20 % from the total value of Levels 1 to 11 (around the 20 %) 3- Sum of Levels (10 + 11) should be Less Than 25 % from the total value of Levels 1 to 11 (around the 25 %)
2.4 Normal Trend for Path-Balance The Normal Trend of the balance means that the measurement should be around level 6 as shown below
TRX Path-Balance Check Confidentiality:
2012-03-13 Huawei Confidential Page 7 of 10
2.5 Weak DL Trend for Path-Balance Weak DL means that the measurement of the UL Level counters is higher than the DL counters (Levels 1+2 is Higher than 20 % from the total Measurement)
TRX Path-Balance Check Confidentiality:
2012-03-13 Huawei Confidential Page 8 of 10
2.6 Weak UL Trend for Path-Balance Weak DL means that the measurement of the DL Level counters is higher than the UL counters (Levels 10+11 is Higher than 25 % from the total Measurement)
TRX Path-Balance Check Confidentiality:
2012-03-13 Huawei Confidential Page 9 of 10
2.7 Misleading Case for Path-Balance In the below case the measurement of Levels 10+11 is 22% which is good and accepted but from the TRX chart we can see that the TRX suffers from Weak-UL status as shown below
So the conclusion from this case is that:
1- Percentage is just an indication to determine the worst cases 2- The judgment must be done for case by case specially for the TRXs with percentage around 20% for both UL/DL indicators (Levels 1+2 or Level 10+11)
TRX Path-Balance Check Confidentiality:
2012-03-13 Huawei Confidential Page 10 of 10
3 Appendix Not Required 4 Support Document(s) No. Document name Document code 1.
5 Related Document(s) Front-end and Back-end Document name Document Code
6 Record Retention Record Name Hand over Owner Retention Owner Retention Location Filing Date Retention Period Disposition at Expiry Problem escalation (GCRMS)
7 Document Preparation/Modification Record (Manda tory) Version Prepared/Modified By Preparation/Modification Date Content/Reason for Modification Approved By V1.00 Mostafa Ibrahim 701891 (Egypt 3 rd licence) 2010.8.31 New Version Zhu yongsheng 108866