Annual precipitation: 83.

00 mm/year
Drought precipitation: 0.00 mm/year Not Given
Evaporation rate: 2421.00 mm/year
Annual net evaporation capability: 2338.00 mm/year
Net pan evaporation: 2.34 m/year
Factor for salinity correction: 0.87
Pan factor 0.85
Design basis evaporation rate: 1.72 m/year
Effluents to Evaporation pond: 46641.89 m3/year
Equivalent hours at 100%: 24 hour/day
Annual flow to Evaporation pond: 27040.61 m3/year
Evaporation ponds area: 15676.781 m2 he
Depth of Pond 1.72 m
125.41425
Design according to Pre-feasibility study of brine effluent evaporation for Abengoa solar
(To determinate an equivalent evaporation rate in the ponds a factor for salinity correction is used
since the evaporation ponds will be a high dissolved solids concentration which will afeect the
Urban distribution network
WTP Vendor
City water supply
Abeinsa
WTP Vendor
Filter Feedpumps
2 X 100%
Drinking water
tank
30 m3
4
Filter Backwash
4
Raw Water
Tank
Drinking Water
3
11
2
1
Streams Descripction Unit
1 Drinking Water from Existing Water System m3/h
2 Raw Water at Tank m3/h
3 Fire Fighting m3/h
4 Filter Water Inlet m3/h
5 SAC Inlet m3/h
6 SBA Inlet m3/h
7 MB Inet m3/h
8 DM Water m3/h
9 Service Water for plant m3/h
10 Service water for chemicals m3/h
11 m3/h
12 DM Water for make up of evaporative cooling m3/h
13 Make-up water for HRSG Blowdown m3/h
14 Auxiliary cooling closed circuit make-up water m3/h
15 Make-up for Auxiliary Boiler m3/h
16 DM Water for GT Washing m3/h
17 Auxiliary Waste Water to N-pit m3/h
18 m3/h
19 Sanitary Waste Water m3/h
20 Chemical drains to N-pit m3/h
21 Steam cycle blowdown to N-pit m3/h
22 Waste Water from DM Plant to N-Pit m3/h
23 Waste Water from N-Pit to Collection Basin m3/h
24 Waste Water from collection basin to evaporation pond m3/h
25 DM Water for Thermal Cycle Make-up m3/h
Service water for other cleanings
Waste Water from Plant to collection basin
WTP Vendor
WTP Vendor
Drinking water
consumers
Other cleanings
Oily wastewater

Oil Water
Oil / water separator
SBA
(2X100%)
MB
(2X100%)
Drinking water
tank
30 m3
19
22
6
Filter Backwash
Waste
Strong Acid
Cation
2x100%
Sanitary
Multi-Grade filter
2x100%
SAC Waste
SBA Waste
MB Waste
Fire Fighting System
Chemicals for
Degassed Water
Tank 30m3
7
5
5.00
10.40
0.00
10.40
10.20
9.98
9.76
9.58
1.25
0.75
0.50
2.16
4.43
1.06
0.16
0.04
1.26
0.50
5.00
0.75
1.48
0.82
4.90
5.40
1.73
Chemicals for
Neutralisation/pH
Adjustment
Abeinsa
WTP Vendor
Steam cycle make-up
Auxiliary cooling water closed circuit
Service Water for
Plant
Chemical Preparation
DM Water
Storage Tank
10
13
Auxiliary Boiler Make up
20
9
Chemicals for
8
14
15
21
GT Washing
16
Neutralisation Pit
Make-up for evaporative colling
12
17
23
18
Thermal cycle make-up 25
Abeinsa
Evaporation Pond
Collection Basin
Neutralization Pit Pumps (NPP)
Chemicals for
Neutralisation/pH
Adjustment
24
Efflunet Transfer Pumps ETP)
23
Chemical Cleaning Waste to WWTP
Condensate hot well
HRSG
Turbine
18
Evaporation Pond