Sie sind auf Seite 1von 120

Remote Panel Large # of devices

In Panel
Remote Panel Near or < # of Devices
PLC
HMI
MIPP
VFD
HMI
Switch
Drv Drv
<30 - 60m
I/O
I/O
Switch
Switch
On Machine I/O
On Machine SW
Octopus
IP-67 Rated
Hirschmann
UTP
S/ScTP
Stranded Cond.
If > 30 - 60m
UTP -S/ScTP
Stranded Cond.
Preferred
Factory ,
Field (ok)
Terminated
Typ. in Conduit
Factory Patch Cord.
Stranded TP.
General
Belden
Quabbin
AB
1port DIN
Adaptor
BTR
Panduit
M-12 Patch Cord
IP-67
Hirschmann
UTP Solid Cond.
If < 100m , if > 100m = fiber
M-12 Patch Cord
IP-67
Hirschmann
Industrial Ethernet outline for Acct Mgr 120612 support docs1.vsd
Movable Panel
VFD
Factory Patch Cord.
Stranded TP.
Consider 600v Cable
General
Quabbin
AB
Belden
IP-67 Bulkhead
Adaptor
BTR
Panduit
Hirschmann
General
Quabbin
Belden
General
Belden
Quabbin
General
Quabbin
Belden
AB
Hirschmann
Panduit
AB
Lock In
Panduit
Block Out
Panduit
Block Out
Panduit
1port DIN
Adaptor
BTR
Panduit
12/5/2012
12/5/2012
1.717.217.2299 www.belden.com/hirschmann 37
Be Certain with Belden
OCTOPUS IP67 / IP54 Industrial On-Machine Ethernet Switches
300ms
HiPer-Ring
OCTOPUS Fast Ethernet Unmanaged Waterproof IP67 / IP54 Switches
Part No. Order No. Ports/Functions
OCTOPUS 5TX EEC 943 892-001 5 x 10/100 Mbps M12-coding, Unmanaged
OCTOPUS OS20-001000T5T5TAFUHB 942 025-001 10 x 10/100 BASE-TX, M12 D coding, 4-pole
OCTOPUS OS20-001000T5T5TNEUHB 942 025-004 10 x 10/100 BASE-TX, M12 D coding, 4-pole,
(110 V version)
OCTOPUS PoE Fast Ethernet Unmanaged Waterproof IP67 / IP54 Switches
Part No. Order No. Ports/Functions
OCTOPUS OS24-081000T5T5TFFUHB
Available: Q4, 2012
942 025-003 8 x10/100 Base-TX PoE (Phantom Power) and
2 x10/100 Base-TX (24 V version)
OCTOPUS OS24-081000T5T5TNEUHB
Available: Q4, 2012
942 025-004 8 x10/100 Base-TX PoE (Phantom Power) and
2 x10/100 Base-TX (110 V version)
The OCTOPUS family of switches meet all relevant industry standards and are the most robust
switches in the market. With Power over Ethernet , Professional frmware standard on all models
and Gigabit connectivity for where a higher bandwidth connection is required.
All products in the OCTOPUS family can be mounted on the wall or directly on the machine.
The IP67 variants offer 8/16/24 Twisted Pair ports (each with up to 8 PoE ports), using ODVA-
standardized 4-pin M12 D-code technology. As the switches are freely cascadable, it is simple to
build decentralized structured networks with the shortest possible patch cables to the end devices.
The OS20 and OS30 switches utilize IP67 fber connections per the IEC 61076-3-106 standard
- Variant 1 is approved by ODVA for use with EtherNet/IP, Variant 4 is approved for use with
PROFINET.
Standard features include: Totally enclosed IP67 design, ODVA-standardized 4-pin M12 D-code
IP67 Ethernet connector, OCTOPUS M is the industrys frst managed IP67 switch, Management
via SNMP v1, v2, v3, web GUI or TELNET, Redundancy via HIPER-Ring and Rapid Spanning Tree,
Redundant power supply for high availability, Operating temperatures as low as 40 C to + 70 C,
and External signaling of alarms via signal contact or network messaging.
Home
1.717.217.2299 38 www.belden.com/hirschmann
OCTOPUS Fast Ethernet Managed Waterproof IP67 / IP54 Switches
Part No. Order No. Ports/Functions
OCTOPUS 8M 943 931-001 8 x 10/100 BASE-TX, M12 D-coding, 4-pole
OCTOPUS 8M Train 943 983-001 8 x 10/100 BASE-TX, M12 D-coding, 4-pole,
(EN 50155)
OCTOPUS OS20-000900T5T5TAFBHH 942 025-005 9 x 10/100 BASE-TX, M12 D-coding, 4-pole
OCTOPUS OS20-000900T5T5TNEBHH 942 025-006 9 x 10/100 BASE-TX, M12 D-coding, 4-pole,
(110 V version)
OCTOPUS OS20-0010001M1MTREPHH 943 988-001 8 x 10/100 BASE-TX, M12 D coding, 4-pole,
2 x 100 BASE FX Multimode Ports IAW IEC 63076-
3-106, Version 1
OCTOPUS OS20-0010004M4MTREPHH 943 988-003 8 x 10/100 BASE-TX, M12 D coding, 4-pole,
2 x 100 BASE FX Multimode Ports IAW
IEC 63076-3-106, Version 4
OCTOPUS OS20-0010001S1STREPHH 943 988-002 8 x 10/100 BASE-TX, M12 D coding, 4-pole,
2 x 100 BASE FX Singlemode Ports IAW
IEC 63076-3-106, Version 1
OCTOPUS OS20-0010004S4STREPHH 943 988-004 8 x 10/100 BASE-TX, M12 D coding, 4-pole,
2 x 100 BASE FX Singlemode Ports IAW
IEC 63076-3-106, Version 4
OCTOPUS 16M 943 912-001 16 x 10/100 BASE-TX, M12 D-coding, 4-pole
OCTOPUS 16M-Train 943 984-001 16 x 10/100 BASE-TX, M12 D-coding, 4-pole,
(EN 50155)
OCTOPUS 24M 943 923-001 24 x 10/100 BASE-TX, M12 D coding, 4-pole
OCTOPUS 24M Train 943 985-001 24 x 10/100 BASE-TX, M12 D coding, 4-pole,
(EN 50155)
OCTOPUS PoE Fast Ethernet Managed Waterproof IP67 / IP54 Switches
Part No. Order No. Ports/Functions
OCTOPUS 8M-6PoE 943 967-101 6 x 10/100 BASE-TX PoE (phantom power) and
2 x 10/100 BASE-TX , M12 D coding, 4-pole
OCTOPUS 8M-8PoE 943 967-001 8 x 10/100 BASE-TX PoE (phantom power), M12
D coding, 4-pole
OCTOPUS IP67 / IP54 Industrial On-Machine Ethernet Switches
Home
1.717.217.2299 www.belden.com/hirschmann 39
Be Certain with Belden
OCTOPUS IP 67 / IP 54 Industrial On-Machine Ethernet Switches
OCTOPUS OS24-080900T5T5TFFBHH
Available: Q4, 2012
942 025-007 8 x10/100 Base-TX PoE-Plus (Phantom Power) and
1x10/100 Base-TX (24 V version)
OCTOPUS OS24-080900T5T5TNEBHH
Available: Q4, 2012
942 025-008 8 x10/100 Base-TX PoE-Plus (Phantom Power) and
1x10/100 Base-TX (110 V version)
OCTOPUS 16M-8PoE 943 960-001 8 x 10/100 BASE-TX PoE (phantom power) and
8 x 10/100 BASE-TX, M12 D coding, 4-pole
OCTOPUS 24M-8 PoE 942 063-001 8 x 10/100 BASE-TX PoE (phantom power) and
16x 10/100 BASE-TX, M12 D-coding, 4 pole
OCTOPUS Gigabit Ethernet Managed Waterproof IP67 / IP54 Switches
Part No. Order No. Ports/Functions
OCTOPUS OS30-0008021A1ATREPHH 943 988-005 8 x 10/100 BASE-TX, 2x Gigabit Multimode Ports
IAW IEC 63076-3-106, Version 1
OCTOPUS OS30-0008024A4ATREPHH 943 988-007 8 x 10/100 BASE-TX, 2x Gigabit Multimode Ports
IAW IEC 63076-3-106, Version 4
OCTOPUS OS30-0008021B1BTREPHH 943 988-006 8 x 10/100 BASE-TX, 2x Gigabit Singlemode Ports
IAW IEC 63076-3-106, Version 1
OCTOPUS OS30-0008024B4BTREPHH 943 988-008 8 x 10/100 BASE-TX, 2x Gigabit Singlemode Ports
IAW IEC 63076-3-106, Version 4
OCTOPUS PoE Gigabit Ethernet Managed Waterproof IP67 / IP54 Switches
Part No. Order No. Ports/Functions
OCTOPUS OS32-080802T6T6TPEPHH
Available: Q3, 2012
942 069-002 8 x10/100 BASE-TX PoE (phantom power) and
2 x1000 BASE-TX
OCTOPUS OS32-081602T6T6TPEPHH
Available: Q3, 2012
942 069-001 8 x10/100 BASE-TX PoE (phantom power) and
8 x10/100 BASE-TX
2 x1000 BASE-TX
OCTOPUS OS32-080802O6O6TPEPHH
Available: Q3, 2012
942 069-004 8x 10/100 BASE-TX PoE (phantom power) and
2x SFP- sockets for 10/100 BASE-FX and 1000
BASE-X housing IEC 63076-3106 v1
OCTOPUS OS32-081602O6O6TPEPHH
Available: Q3, 2012
942 069-003 8x 10/100 BASE-TX PoE (phantom power) and
8x 10/100 BASE-TX and
2x SFP- sockets for 10/100 BASE-FX and 1000
BASE-X housing IEC 63076-3106 v1
OCTOPUS IP 67 Connectivity Solutions
Part No. Order No. Description
EM12S OCTOPUS 934 445-001 Field-installable M12 (IP67) Ethernet connector
EF12RJ45 OCTOPUS 934 498-001 Bulkhead M12 to RJ45
ACA21-M12 EEC 943 913-002 ACA 21 auto conguration adapter for OCTOPUS managed switches
OCTOPUS Terminal Cable 943 902-001 M12 4-pin to Sub-D- 9-pin terminal cable
Home
1.717.217.2299 40 www.belden.com/hirschmann
OCTOPUS IP 67 Industrial On-Machine Ethernet Switches
N N A M H C S R I H
N N A M H C S R I H
N N A M H C S R I H
N N A M H C S R I H
N N A M H C S R I H
N N A M H C S R I H
Harte Industrieumgebung
Schaltschrankinstallation
Whenever reliable, intelligent, and efcient data transmission has to be guaranteed under extreme condtions, the OCTOPUS family offers a robust solution. Sturdy
housing and connector technology together with powerful management functionality make the OCTOPUS the best solution when high network availability is
necessary. In addition to being ideal for environmentally challenging applications at the eld level, the OCTOPUS is also ideal for transportation applications, such as
trafc/system control and on-board communication systems.
Harsh Industrial
Environment
Cabinet Installation
Home
N.1 www.panduit.com For service and technical support, call 866-405-6654 (outside the U.S. and Canada, see back cover).
A.
System
Overview
B.
Copper
Systems
C.
Fiber
Optic
Systems
D.
Power
over
Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
PHYSICAL INFRASTRUCTURE SOLUTIONS
INDUSTRIAL
The Panduit

IndustrialNet

Solution is a reliable, high performance network cabling infrastructure


designed to support industrial networking applications in harsh factory environments. IP (Ingress
Protection) and NEMA (National Electrical Manufacturers Association) rated products, including
hardened network connectivity, withstand the harsh conditions encountered in industrial
automation and industrial Ethernet applications.
Connectors rated for factory and harsh
environments NEMA 6, 6P and IP67/IP65
Fully integrated solution with proven
interoperability from the enterprise to the
industrial network
Reduced cost of ownership for design, installation,
and management of industrial networking
The IndustrialNet

Solution includes IndustrialNet

TX6

, TX5e

Connectors, Patch Cords,


Industrial Automation 4 Post Rack, IndustrialNet

LC Fiber Optic Bulkhead Adapter and Patch Cords,


IndustrialNet

Ethernet Enclosures, and IndustrialNet

Stainless Steel Faceplates.


Home
N.2 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.
PHYSICAL INFRASTRUCTURE SYSTEMS
A.
System
Overview
B.
Copper
Systems
C.
Fiber
Optic
Systems
D.
Power
over
Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
Industrial System Roadmap
IndustrialNet

Ethernet Enclosures
(page N.3)
1
IndustrialNet

Connectors and
Patch Cords
(pages N.4 N.8)
2
Cabinets, Racks, and
Cable Management
(pages L.1 L.100)
3
Cable Management
Accessories
(pages L.87 L.88)
4
Power and Grounding
Connectors
(pages M.1 M.58)
5
5
Wiring Duct
(pages P.1 P.17)
6
Labeling and
Identification
(pages O.1 O.30)
7
Cable Ties and
Cable Tie Tools
(pages P.19 P.40)
8
3
2
6
4
5
7
8
4
1
DIN Rail
Mount Adapter
(page N.4)
9
9
Home
N.3 www.panduit.com
A.
System
Overview
B.
Copper
Systems
C.
Fiber
Optic
Systems
D.
Power
over
Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
PHYSICAL INFRASTRUCTURE SOLUTIONS
IndustrialNet

Ethernet Enclosure, Rack, and Accessories


Enclosure with pre-configured back plate and side panels
to accept Stratix^^ 8000, 5700 or or Cisco^ IE3000,
IE2000 industrial switches with expansion modules
and a UPS
Pre-configured enclosure with cable management,
network connectivity, grounding, wire routing accessories
with pre-configured back plate and side panels to accept
Stratix^^ 8000, 5700 or Cisco^ IE3000, IE2000 industrial
switches with expansion modules and a UPS
Pre-configured enclosure has all cable management
components installed to get started; includes: Category 6
connectivity, patch cords, patch panel, wiring accessories,
ground bar, and cable management
Reversable hinging door for installation flexability
Internal side utility panels pre configured for modular cable
management, fiber uplink, and other accessory mounting
Enclosures meet UL 508 standards and are NEMA Type 4,
12, and IP66 rated for industrial environments
Wall mountable through enclosure or with removable
mounting flanges for mounting flexibility
4 post industrial cage nut rack accommodates 19"
EIA mountable equipment for use in manufacturing
data centers
4 post industrial cage nut rack has two adjustable depths
for flexibility in equipment mounting
Industrial Automation DIN rail bracket allows automation
equipment to be mounted in 19" EIA rack
IAZ2436C
IAZ2436
IAZ2424
IAZ2424C
IAZ1214
IAZ1214C
^Cisco is a registered trademark of Cisco Technology, Inc.
^^Stratix 8000 is a trademark of Rockwell Automation, Inc.
Table continues on page N.4
For service and technical support, call 866-405-6654 (outside the U.S. and Canada, see back cover).
Part Number Part Description
Std.
Pkg.
Qty.
IAZ2436 Industrial automation zone enclosure with pre-configured backplane
for up to two Stratix^^ 8000 or Cisco^ IE3000 series industrial switches
with expansion modules, UPS, and power supplies.
1
IAZ2436C Fully pre-configured industrial automation zone enclosure with
pre-configured backplane, cable management, and high voltage
isolation barrier. For up to two Stratix^^ 8000 or Cisco^ IE3000 series
industrial switches with expansion modules, UPS, and power supplies.
1
IAZ2424 Industrial automation zone enclosure with pre-configured backplane
for one Stratix^^ 5700 or Cisco^ IE2000 series industrial switches with
UPS and power supplies.
1
IAZ2424C Fully pre-configured industrial automation zone enclosure with
pre-configured backplane, cable management, and high voltage
isolation barrier. For one Stratix^^ 5700 or Cisco^ IE2000 series
industrial switches with expansion modules, UPS, and power supplies.
1
IAZ1214 Industrial automation zone enclosure with pre-configured backplane
for one Stratix^^ 5700 industrial switch and cabling.
1
IAZ1214C Industrial automation zone enclosure pre-configured for one Stratix^^
5700 industrial switch, with cable management.
1
PZNF1 NEMA 4X rated compression fitting, ideal for cable diameters of .115"
to .250" (2.82mm to 6.35mm).
1
PZNF2 NEMA 4X rated compression fitting, ideal for cable diameters of .230"
to .395" (5.84mm to 10.03mm).
1
PZNF3 NEMA 4X rated compression fitting, ideal for cable diameters of .170"
to .450" (4.32mm to 11.43mm).
1
PZNDVK NEMA 4X drain and vent kit. 1
Home
N.4 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.
PHYSICAL INFRASTRUCTURE SYSTEMS
A.
System
Overview
B.
Copper
Systems
C.
Fiber
Optic
Systems
D.
Power
over
Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
IndustrialNet

Ethernet Enclosure, Rack, and Accessories (continued)


FLCDMCXAQY
CBXF6BL-AY
CADIN1IG
CMDSAQLCBL
FXE10-10M1Y
FDME8RG CDPP8RG
IAR4P48CN
IABDIN4
Std.
Pkg.
Qty. Part Description Part Number
Industrial Rack and Accessories
IAR4P48CN Industrial automation 4 post rack system. 24 RU high, cage nut
equipment rails.
Dimensions: 48.0H x 23.2W (1219mm) x (589mm)
Depth adjustable at either 23.0 or 29.0 (584mm) or (737mm)
1
IABDIN4 Industrial automation bracket for standard EIA 19 wide rack or cabinet.
Installs DIN rail mountable equipment. 4 RU high.
1
Copper Connectivity Accessory
CADIN1IG Mini-Com

DIN Rail Mount Adapter mounts to standard 35mm DIN rail


and accepts any single port Mini-Com

Module. Includes a label and


label cover.
1
Fiber Uplink Accessories
CBXF6BL-AY Mini-Com

surface mount box accepts up to six Mini-Com

Modules.
Includes built-in fiber spool that stores up to 24 meters of buffered fiber
optic cable. Icon slots available for optional icons. Dimensions: 0.98"H x
4.70"W x 6.66"L (25.0mm x 119.4mm x 169.2mm)
1
FLCDMCXAQY LC OptiCam

10Gig

50/125m OM3/OM4 Multimode Duplex Fiber


Optic Connector for 900m tight-buffered fiber installation.
1
CMDSAQLCBL Module supplied with one LC Sr./Sr. 10Gig

OM3/OM4 SFF Duplex


Multimode Fiber Optic Adapter (AQ) with phosphor bronze split sleeves.
1
FXE10-10M1Y LC to LC multimode duplex patch cord, 1.6mm jacketed cable
(two duplex LC connectors on each end) 10Gig

50/125m.
1
IndustrialNet

8-port DIN Rail Mount Patching Solutions


FDME8RG 8-port DIN Rail Fiber Optic Enclosure provides enclosed fiber protection
for terminated distribution style cabling and includes a PG21 or 3/4 NPT
cable cord grip to secure fiber cable(s) exiting the enclosure.
1
CDPP8RG IndustrialNet

8-port DIN rail mount copper patch panel.


Mounting latches securely mount unit to standard DIN rail in industrial
applications. Can also mount to other surfaces using mounting holes in
latches. Includes screws to attach faceplate and Ultimate ID labels and
clear label covers.
1
Home
N.5 www.panduit.com For service and technical support, call 866-405-6654 (outside the U.S. and Canada, see back cover).
A.
System
Overview
B.
Copper
Systems
C.
Fiber
Optic
Systems
D.
Power
over
Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
PHYSICAL INFRASTRUCTURE SOLUTIONS
IndustrialNet

TX6

Connectors
Bulkhead provides IP67/IP65 seal when mated with
IP67/IP65 plug or patch cord
Designed to exceed performance requirements of the
ANSI/TIA-568-C.2 Category 6 and ISO 11801 2nd Edition
Class E standards
Meet industrial Ethernet specifications from ODVA, TIA,
and IEC sealed RJ45 connectors
Utilize Panduit patented enhanced Giga-TX

Termination
technique for consistent, reliable terminations
Jack module terminates 4-pair 22 26 AWG solid and
stranded twisted pair cable
Gasket and seal made of inert, chemically
resistant material
Connector components are made of high temperature
rated material
Tethered caps maintain seal during unmated connection
Compatible with leading switch manufacturers equipment
IAEBH6S
EGJT tool terminates enhanced Giga-TX

Style Jack Modules, available on page B.92.


Not suitable for direct UV applications.
IndustrialNet

TX6

Coupler
Provides convenient plug to plug connection point
between the hardened switch and automation device
Bulkhead provides IP67/IP65 seal when mated with
IP67/IP65 plug or patch cord
Designed to exceed performance requirements of the
ANSI/TIA-568-C.2 Category 6 and ISO 11801 2nd
Edition Class E standards
Meet industrial Ethernet specifications from ODVA, TIA,
and IEC sealed RJ45 connectors
Meet requirements of IEEE 802.af and IEEE 802.3at for
PoE applications
Gasket and seal made of inert, chemically
resistant material
Connector components are made of high temperature
rated material
Tethered caps maintain seal during unmated connection
Compatible with leading switch manufacturers equipment
Acts as one connecting hardware component in channel.
Not suitable for direct UV applications.
Part Number Part Description
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
IAEBHC6 Category 6, RJ45, 8-position, 8-wire black industrial bulkhead
coupler with protective cover.
1 10
Part Number Part Description
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
IndustrialNet

TX6

UTP Bulkhead Connector


IAEBH6 Category 6, RJ45, 8-position, 8-wire black industrial bulkhead
connector with protective cover.
1 10
IndustrialNet

TX6

Shielded Bulkhead Connector


IAEBH6S Category 6, RJ45, 8-position, 8-wire shielded black industrial
bulkhead connector with protective cover.
1 10
IAEBHC6
Home
N.6 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.
PHYSICAL INFRASTRUCTURE SYSTEMS
A.
System
Overview
B.
Copper
Systems
C.
Fiber
Optic
Systems
D.
Power
over
Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
IndustrialNet

TX5e

Connectors
Bulkhead provides IP67/IP65 seal when mated with
IP67/IP65 plug or patch cord
Exceed ANSI/TIA-568-C.2 Category 5e and ISO 11801
2nd Edition Class D standards
Meet the industrial Ethernet specifications from ODVA,
TIA, and IEC for sealed RJ45 connectors
Utilize Panduit patented Giga-TX

Termination technique
for consistent, reliable terminations
Terminate 4-pair 22 26 AWG solid and stranded twisted
pair cable
Gasket and seal made of inert, chemically
resistant material
High temperature rated material
Tethered caps maintain seal during unmated connection
EGJT tool terminates enhanced Giga-TX

Style Jack Modules, available on page B.82.


Not suitable for direct UV applications.
Part Number Part Description
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
IndustrialNet

TX5e

UTP Bulkhead Connector


IAEBH5E Category 5e, 8-position, 8-wire industrial connector
with protective cover.
1 10
IndustrialNet

TX5e

Shielded Bulkhead Connector


IAEBH5ES Category 5e, 8-position, 8-wire shielded industrial connector
with protective cover.
1 10
IndustrialNet

TX6

PLUS Patch Cords


Exceed ANSI/TIA-568-C.2 Category 6 and ISO 11801
Class E standards
Meet requirements of IEEE 802.3af and IEEE 802.3at for
PoE applications
Each patch cord is 100% performance tested and wired
to T568B
Constructed of industrial Category 6, 24 AWG UTP or 26
AWG shielded stranded cable and modular plugs for
superior performance
Plug contacts plated with 50 microinches of gold for
superior performance
Plug meets all applicable ANSI/TIA/EIA-968-A
requirements and exceeds IEC 60603-7 specifications
Bulkhead provides IP67/IP65 seal when mated to an
IP67/IP65, NEMA 6 or 6P bulkhead connector
Patch cords are pre-terminated and provide IP67/IP65
seal when mated to IP67/IP65 bulkhead connectors
Available with or without dust caps
IUTPSP*BL
IUTPSPNC*BL
*For lengths other than 3 feet (5, 7, 10, 15, or 20 feet) change the length designation in the part number to the
desired length.
**For lengths other than 1 meter (2, 3, or 5 meters) change the length designation in the part number to the
desired length.
Part Number Part Description
Length
Std.
Pkg.
Qty.
Std.
Ctn.
Qty. Ft. m
IndustrialNet

TX6

PLUS UTP Patch Cords


IUTPSP3BL* Patch cord constructed of industrial grade UTP
Category 6 stranded cable with modular plugs.
Includes dust caps.
3 0.91 1 10
IUTPSPNC3BL* Patch cord constructed of industrial grade UTP
Category 6 stranded cable with modular plugs.
Does not include dust caps.
3 0.91 1 10
IndustrialNet

TX6

PLUS Shielded Patch Cords


ISTPSP1MBL** Patch cord constructed of industrial grade shielded
Category 6 stranded cable with shielded modular
plugs. Includes dust caps.
3.28 1 1 10
ISTPSPNC1MBL** Patch cord constructed of industrial grade shielded
Category 6 stranded cable with shielded modular
plugs. Does not include dust caps.
3.28 1 1 10
IAEBH5E
Home
N.7 www.panduit.com For service and technical support, call 866-405-6654 (outside the U.S. and Canada, see back cover).
A.
System
Overview
B.
Copper
Systems
C.
Fiber
Optic
Systems
D.
Power
over
Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
PHYSICAL INFRASTRUCTURE SOLUTIONS
IndustrialNet

TX5e

Modular Plugs
Bulkhead provides IP67/IP65 seal when mated with
IP67/IP65 connector or coupler
Exceed ANSI/TIA-568-C.2 Category 5e and ISO 11801
2nd Edition Class D standards
Terminate 24 gauge, stranded or solid conductor with
maximum conductor insulation diameter of .040"
Gasket and seal made of inert, chemically
resistant material
Connector components are made of high temperature
rated material
Tethered caps maintain seal during unmated connection
Compatible with leading switch manufacturers equipment
MPI588T
MPT5-8A crimp tool required for termination, available on page B.93.
Not suitable for direct UV applications.
Part Number Part Description
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
IndustrialNet

TX5e

UTP Modular Plug


MPI588T Category 5e, RJ45 industrial plug with protective cover. 1 10
IndustrialNet

TX5e

Shielded Modular Plug


MPSI588T Category 5e, RJ45 shielded industrial plug with protective cover. 1 10
IndustrialNet

TX5e

Coupler
Provides convenient plug to plug connection point
between the hardened switch and automation device
Bulkhead provides IP67/IP65 seal when mated with
IP67/IP65 plug or patch cord
Designed to exceed performance requirements of the
ANSI/TIA-568-C.2 Category 5e and ISO 11801 2nd
Edition Class D standards
Meets industrial Ethernet specifications from ODVA, TIA,
and IEC sealed RJ45 connectors
Gasket and seal made of inert, chemically
resistant material
Connector components are made of high temperature
rated material
Tethered caps maintain seal during unmated connection
Compatible with leading switch manufacturers equipment
Acts as one connecting hardware component in channel.
Not suitable for direct UV applications.
Part Number Part Description
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
IAEBHC5E Category 5e, RJ45, 8-position, 8-wire industrial black bulkhead
coupler with protective cover.
1 10
IndustrialNet

USB Coupler
Part Number Part Description
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
IAEBHUSBAA IndustrialNet

Mini-Com

USB 2.0 female A to female A


coupler module.
1 10
Provides interface for transmitting data between devices
such as scanners, digital cameras, printers, etc.
Accepts USB 2.0 Patch Cords and is backwards
compatible with USB 1.1 Patch Cords
Supports cable lengths up to 15 feet between devices
Bulkhead provides IP67/IP65 seal when mated with
IP67/IP65 plug or patch cord
Meets industrial Ethernet specifications from ODVA, TIA,
and IEC sealed RJ45 connectors
Gasket and seal made of inert, chemically
resistant material
Connector components are made of high temperature
rated material
Tethered caps maintain seal during unmated connection
IAEBHUSBAA
IAEBHUSBAA
Home
N.8 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.
PHYSICAL INFRASTRUCTURE SYSTEMS
A.
System
Overview
B.
Copper
Systems
C.
Fiber
Optic
Systems
D.
Power
over
Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
IndustrialNet

LC Fiber Optic Bulkhead Adapter and Patch Cords


IAEF7JMA IAEF617P-7PM1
Bulkhead includes duplex multimode LC adapter with phosphor bronze split sleeves.
*For lengths other than one meter (2, 3, 10, 20, and 30 meter lengths) change the length description in the part
number to the desired lengths.
**Contact Panduit Customer Service for pigtail lengths and/or discrete length patch cords with LC fiber interface.
IndustrialNet

Patch Cords are pre-terminated


and provide IP67 seal when mated to IP67
bulkhead adapters
Patch cords built with 62.5m multimode duplex
industrial-grade jacketed fiber cable
Ideal for daisy-chaining hardened industrial switches
between IP66 rated enclosures
Pigtails are ideal for routing fiber through conduit
Patch cords are 100% factory tested for insertion loss
Insertion loss data is recorded for every multimode
patch cord, providing lifetime traceability to a QC number,
labeled on each patch cord
Part Number Part Description
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
IndustrialNet

LC Fiber Optic Bulkhead Adapter


IAEF7JMA Industrial LC fiber bulkhead adapter. 1 10
IndustrialNet

LC Fiber Optic Patch Cord and Pigtail


IAEF617P-7PM1* Industrial duplex multimode 62.5m LC to LC patch cord. 1 10
IAEF617P-NM1** Industrial duplex multimode 62.5m LC to pigtail. 1 10
IndustrialNet

TX5e

Patch Cords
Exceed ANSI/TIA-568-C.2 Category 5e and ISO 11801
Class D standards
Meet requirements of IEEE 802.3af and IEEE 802.3at for
PoE applications
Each patch cord is 100% performance tested and wired
to T568B
Constructed of industrial Category 5e, 24 AWG UTP or 26
AWG shielded stranded cable and modular plugs for
superior performance
Plug contacts plated with 50 microinches of gold for
superior performance
Plug meets all applicable ANSI/TIA/EIA-968-A
requirements and exceeds IEC 60603-7 specifications
Bulkhead provides IP67/IP65 seal when mated to an
IP67/IP65, NEMA 6 or 6P bulkhead connector
Patch cords are pre-terminated and provide IP67/IP65
seal when mated to IP67/IP65 bulkhead connectors
Available with or without dust caps
*For lengths other than 3 feet (5, 7, 10, 15, or 20 feet) change the length designation in the part number to the
desired length.
**For lengths other than 1 meter (2, 3, or 5 meters) change the length designation in the part number to the
desired length.
IUTPCH*BLY
IUTPCHNC*BLY
Part Number Part Description
Length
Std.
Pkg.
Qty.
Std.
Ctn.
Qty. Ft. m
IndustrialNet

TX5e

UTP Patch Cords


IUTPCH3BLY* Patch cord constructed of industrial grade UTP
Category 5e stranded cable with modular plugs.
Includes dust caps.
3 0.91 1 10
IUTPCHNC3BLY* Patch cord constructed of industrial grade UTP
Category 5e stranded cable with modular plugs.
Does not include dust caps.
3 0.91 1 10
IndustrialNet

TX5e

Shielded Patch Cords


ISTPCH1MBLY** Patch cord constructed of industrial grade
shielded Category 5e stranded cable with
shielded modular plugs. Includes dust caps.
3.28 1 1 10
ISTPCHNC1MBLY** Patch cord constructed of industrial grade
shielded Category 5e stranded cable with
shielded modular plugs. Does not include
dust caps.
3.28 1 1 10
Home
N.9 www.panduit.com For service and technical support, call 866-405-6654 (outside the U.S. and Canada, see back cover).
A.
System
Overview
B.
Copper
Systems
C.
Fiber
Optic
Systems
D.
Power
over
Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
PHYSICAL INFRASTRUCTURE SOLUTIONS
IndustrialNet

Stainless Steel Faceplates


Accept IndustrialNet

Connectors and Adapters


Impact resistant for light industrial environments
Rear gasket provides tight seal
IAEFP1 IAEFP2-2G
All faceplates include mounting screws.
Component Labels for IndustrialNet

Stainless Steel Faceplates


Part Number Part Description
No. of
Module
Spaces
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
IAEFP1 Vertical faceplate accepts one IndustrialNet

Bulkhead
Connector or Adapter.
1 1 10
IAEFP2-2G Double gang, vertical faceplate accepts two IndustrialNet

Bulkhead Connectors or Adapters.


2 1 10
IndustrialNet

Data Access Port


Provides a safe and secure means to maintain and
monitor performance of PLCs, VFD, and
industrial networks
Integrated security features prevent access to critical
devices by unauthorized personnel
Allows access by non-arc flash certified personnel
reducing cost, increasing efficiencies, and promoting
overall safety
NEMA 4X rating; constructed of aluminum casted base
with clear, plastic, impact resistant cover, and
modular faceplate
IAPNG5EWH
Part Number Part Description
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
IAPNG5EWH Data access port with GFCI and TX5e

Coupler Module. 1 10
IAPNGWH Data access port with GFCI. 1 10
IAPNWH Empty data access port. 1 10
Suggested Label Solutions for TIA/EIA-606-A Compliance
Faceplate
Part Number
Laser/Ink Jet Desktop
Printer Label
TDP43ME Thermal
Transfer Desktop
Printer Label
PanTher

LS8E
Hand-Held Printer Label
Cougar

LS9
Hand-Held Printer Label
IAEFP1 C061X030FJJ C061X030YPT C061X030FJC T031X000FJC-BK
IAEFP2-2G 2 C061X030FJJ 2 C061X030YPT 2 C061X030FJC T031X000FJC-BK
For complete labeling solutions and product information, reference charts on pages O.1 O.22.
Home

Hirschmann Automation and Control GmbH www.beldensolutions.com

04-12-2012
Page1of2

Product information
EM12S OCTOPUS
Industrial Ethernet:Waterproof IP67/IP54 Switches:Connecting technology:EM12S OCTOPUS
http://www.e-catalog.beldensolutions.com/link/57078-24455-49850-24505-39093/en/conf/uistate
Name EM12S OCTOPUS

Field attachable Industrial ETHERNETM12 connector "D"-coded according IEC 61076-2-101.


Delivery informations
Availability available
Product description
Description Field attachable Industrial ETHERNET
M12 connector "D"-coded according
IEC 61076-2-101.
Type EM12S OCTOPUS
Order No. 934 445-001
Type of contact male
Number of contacts 4
Data rate 10BASE-T, 100BASE-TX
Conductor size AWG 24 - AWG 22
Cable specification stranded wire/solid wire
Standard IEC 61076-2-101
Housing Color metallic
Technical data
Rated voltage AC/DC 250 V
Rated current 4 A (Derating)
Suitable cables diameter 6.0 mm to 8.0 mm
Type of termination IDC
Pin dimensions 1 mm
Material
Contact material Cu Zn
Contact surface material Au
Contact bearer material PA
Housing material Cu Zn/Ni
Coupling nut material Zn
O-Ring Vition
Environmental conditions
Protection class (IEC 60529) IP 67
Pollution severity 3
Temperature range -25 C to +85 C
Approvals
UL UL in pending
Packing unit
Packaging unit 10
Scope of delivery and accessories
Accessories to order separately switch OCTOPUS 5TX EEC,
order no. 943 892-001
media module MM3-4TX5 OCTOPUS,
order no. 943 841-001;
Bulkhead M12 to RJ45 EF12RJ45 OCTOPUS;
order no. 934 498-001
M12 socket EF12M OCTOPUS;
Home

Hirschmann Automation and Control GmbH www.beldensolutions.com

04-12-2012
Page2of2

Industrial Ethernet:Waterproof IP67/IP54 Switches:Connecting technology:EM12S OCTOPUS


http://www.e-catalog.beldensolutions.com/link/57078-24455-49850-24505-39093/en/conf/uistate
order no. 934 450-021
M12 socket EF12L OCTOPUS;
order no. 934 451-021
M12 socket EF12LW OCTOPUS;
order no. 934 451-521
Picture
Drawing
For more information please contact:
Hirschmann Automation and Control GmbH
Stuttgarter Strasse 45-51
72654 Neckartenzlingen
Germany
Phone: +49 7127/14-1809
E-Mail: inet-sales@belden.com

The information published in the websites has been compiled as carefully as possible. It is subject to alteration without notice in technical as well as in price-related/commercial respect.
The complete information and data were available on user documentation. Mandatory information can only be obtained by a concrete query.
Home
B.42 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.
PHYSICAL INFRASTRUCTURE SYSTEMS
A.
System
Overview
B.
Copper
Systems
C.
Fiber
Optic
Systems
D.
Power
over
Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
Mini-Com

TX5e

Corrosive Resistant UTP Jack Module


Injected gel and polymer material reduce area of exposed
electrical contacts providing improved long term
performance in corrosive environments
Exceed requirements of ANSI/TIA-568-C.2 Category 5e,
IEEE 802.3an-2006, and ISO 11801 Class D
channel standards
Exceed requirements of ANSI/TIA-568-C.2 Category 5e
and IEC 61156-5 Category 5e component standards
Meet requirements of IEEE 802.3af and IEEE 802.3at for
PoE applications
Each jack is 100% tested to ensure NEXT and RL
performance and is individually serialized for traceability
Utilizes patent-pending enhanced Giga-TX

Technology
for jack terminations which optimizes performance by
maintaining cable pair geometry and eliminating
conductor untwist
Contacts plated with 50 microinches of gold for
superior performance
No punchdown tool required; termination tool (EGJT)
ensures conductors are fully terminated by utilizing a
smooth forward motion without impact on critical internal
components for maximum reliability
Optional termination tool (TGJT) reduces termination time
by 25%, ideal for high volume installations
Can be re-terminated a minimum of twenty times
Red termination cap designates Category 5e performance
and provides positive strain relief; helps control cable
bend radius and securely retains wires
Terminates 4-pair, 22 26 AWG, 100 ohm, solid or
stranded twisted pair cable
Universal termination cap is color-coded for T568A and
T568B wiring schemes
Accepts 6 and 8-position modular plugs without damage
Can be clearly identified with optional labels and icons
Compatible with Mini-Com

Modular Patch Panels,


Faceplates, and Surface Mount Boxes
Optional RJ45 blockout device blocks out unauthorized
access to jack modules and potentially harmful foreign
objects, saving time and money associated with data
security breaches, network downtime, repair, and
hardware replacement
Optional dust cap keeps out dust and debris while not
in use
For standard colors other than Off White, replace suffix IW (Off White) with WH (White), BL (Black), RD (Red),
or BU (Blue).
Termination tools available on page B.97.
RJ45 blockout device available on page B.92.
Dust cap available on page B.97.
Component Labels for Mini-Com

TX5e

Corrosive Resistant UTP


Jack Module
For complete labeling solutions and product information, reference charts on pages O.1 O.25.
Part Number Part Description
No. of
Module
Spaces Color
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
CJE5E88TGIW Corrosive resistant, Category 5e, RJ45,
8-position, 8-wire universal module.
1 Off
White
1 50
Suggested Label Solutions for TIA/EIA-606-A Compliance
Part Number
Laser/Ink Jet Desktop
Printer Label
TDP43ME Thermal Transfer
Desktop Printer Label
PanTher

LS8E
Hand-Held Printer Label
Cougar

LS9
Hand-Held Printer Label
CJE5E88TG** C138X019FJJ C138X019YPT C138X019FJC T019X000FJC-BK
Home
PB 360
Hirschmann and Belden
Present Industrial Ethernet
Connectivity Solutions
All from One Source. Complete
Ethernet Connectivity Solutions
for Industrial and Mission-Critical
Applications.
Product Bulletin
Table of Conents
Introduction ..........................................1
MIPP .......................................................2-3
19 Rackmount Patch Panels ............4
Fiber Connectivity ................................5
Hirschmann Patch Cords ....................6-7
Belden Patch Cords .............................8-9
Accessories & Connectors .................10-11
Introduction
Belden has assembled the industries most
complete line of connectivity products for
networking applications requiring connectivity
between switches, routers, firewalls, and access
points. Most importantly, the termination of
Ethernet and Fiber cables within a control
cabinet has become increasingly important
in that control cabinets are becoming smaller
and more complex. The management of
Ethernet and Fiber connections have become
an essential part of the overall planning and
installation process.
People realize that their network equipment
is vital to keeping their networks up and
running. What most people may not realize is
that approximately 70% of network downtime
happens because of a failure at the physical
layer. The physical layer primarily consists of
media (copper and fiber) and connectors. By
working with Belden, you can be assured of a
complete end-to-end Ethernet solution from
one source.
End-to-End Ethernet Solution
An end-to-end Ethernet solution consists of a
complete array of managed and unmanaged
Ethernet switches, routers, firewalls, and
access points coupled with the industries
most diversified line of industrial cordsets and
Featured Brands
cable for both copper and fiber terminations.
Finally, Belden and its Hirschmann brand
have developed the industries first modular
industrial patch panel designed to save time
in the installation and streamlining the
troubleshooting process.
Advantages
Recognized and Proven Best in Class Quality
and Technology
One source for end to end industrial
Ethernet solutions
Broadest Hardened Ethernet Product
Portfolio
Knowledgeable Local & Global Support
High flexibility for user configuration and
future expansion
Assured enterprise interoperability
Home
2 1.717.217.2299 www.belden.com/hirschmann
Modular Industrial Patch Panel (MIPP)
Product Congurator
The new MIPP is a termination panel for cables that need connecting to active equipment such as
switches. The MIPP can be confgured to create a large single patch panel, to which, for the frst
time ever, both fber and copper cables can be connected.
The MIPP is a completely new solution that provides the ideal connection between Belden cables
and Hirschmann switches. Available in a choice of modules suitable for both fber and copper
cables, up to 6 modules can be connected to create a single panel that can accommodate both
types of cable at the same time for maximum system fexibility. Using patchcords to connect to
active equipment, cables can be terminated inside the cabinet in an organized and structured
manner to ensure the highest level of reliability.
Design/Model
MIPP - = Modular Industrial Patch Panel
Housing Type
X = No Housing
W = Wall Mount Plate included
D = Standard DIN Rail
Mode (Note: A double module requires two places)
X = No Housing H = 2 x Double module ber
A = 1 x Single module I = 3 x Double module ber
B = 2 x Single module J = 1 x SM + 1 x DM ber
C = 3 x Single module K = 1 x SM + 2 x DM ber
D = 4 x Single module L = 2 x SM + 1 x DM ber
E = 5 x Single module M = 2 x SM + 2 x DM ber
F = 6 x Single module N = 3 x SM + 1 x DM ber
G = 1 x Double module ber O = 4 x SM + 1 x DM ber
Note: SM = Single module and DM = Double module
Module Type
1 = Single module (ber or blind)
2 = Double module (ber or blind)
C = Single copper module
Adapter and Keystone Type
L = LC Duplex adapters
S = SC Duplex adapters (Fiber)
U = Unshielded keystones
S = Shielded keystones (Copper)
N = Blind module
Fiber Type / Category Type for Copper
1 = MM/OM1 E = CAT5e
2 = MM/OM2 D = CAT6
3 = MM/OM3 A = CAT6A
4 = MM/OM4 N = Blind module
9 = SM/OS2
Accessories and Number of Keystones
P = Pigtails
B = Brilliance Field Installable Connectors
2 = 2 keystones
4 = 4 keystones
N = No accessories
MODULE 1 MODULE 2 MODULE 3 MODULE 4 MODULE 5 MODULE 6
M I P P - X X - 1 L 1 P - - - -
Description of Parts Congured:
MIPP patch panel, no housing, (1) OM1 single
fber module, (6) LC duplex adapters, (1) pack
of 12 pigtails.
Home
3
Be Certain with Belden
www.belden.com/hirschmann 1.717.217.2299
MIPP Technical Information
Housing Type and Description
Description Modular Industrial Patch Panel, DIN Rail
Number of Single Modules 1 2 3 4 5 6
Mechanical Construction
Material Housing Aluminium
Dimensions (WxHxD) 42 x 138 x 122 mm 72 x 138 x 122 mm 102 x 138 x 122 mm 132 x 138 x 122 mm 162 x 138 x 122 mm 192 x 138 x 122 mm
Dimensions with Adapters
and Gland, max. (HxD)
165 x 133 mm 165 x 133 mm 165 x 133 mm 165 x 133 mm 165 x 133 mm 165 x 133 mm
Mounting DIN Rail
Appr. Weight (incl.
Modules)
500 g 800 g 1100 g 1400 g 1700 g 2000 g
Protection Class IP20
Module Type and Description
Type Single Module Single Module Double Module Double Module Single Module Single Module
Description 6 x SC Duplex 6 x LC Duplex 12 x SC Duplex 12 x LC Duplex 4 x RJ45 Keystone
Jack, Unshielded
4 x RJ45 Keystone
Jack, Shielded
Mechanical Construction
Material Aluminium
Adapter/Keystone Types Blue SC adapter OS2
UPC zirconia ceramic
Beige SC adapter
OM1/OM2 PC
phosphor bronze
Aqua SC adapter
OM3/OM4 PC zirconia
ceramic
Blue LC adapter OS2
UPC zirconia ceramic
Beige LC adapter OM1/
OM2 PC phosphor
bronze
Aqua LC adapter
OM3/OM4 PC zirconia
ceramic
Blue SC adapter OS2
UPC zirconia ceramic
Beige SC adapter
OM1/OM2 PC
phosphor bronze
Aqua SC adapter
OM3/OM4 PC zirconia
ceramic
Blue LC adapter OS2
UPC zirconia ceramic
Beige LC adapter OM1/
OM2 PC phosphor
bronze
Aqua LC adapter
OM3/OM4 PC zirconia
ceramic
Cat 5e Modular Jack,
Keyconnect AX101310,
black
Cat 6+ Modular Jack,
Keyconnect AX101321,
black
Cat 6A/10GX Modular
Jack, Keyconnect
AX102283, black
Cat 5e Shielded
Modular Jack,
Keyconnect AX104595,
metal body
Cat 6+ Shielded
Modular Jack,
Keyconnect AX104596,
metal body
Cat 6A/10GX Shielded
Modular Jack,
Keyconnect AX104562,
metal body
Cable Entry M16 Gland M16 Gland M20 Gland M20 Gland
Maximum Diameter Cable 10 mm 10 mm 13 mm 13 mm 4 x 7.5 mm 4 x 7.5 mm
Cable Types Loose-tube, minibreakout
or breakout
cables of up to 12 bers
Loose-tube, minibreakout
or breakout
cables of up to 12 bers
Loose-tube, minibreakout
or breakout
cables of up to 24 bers
Loose-tube, minibreakout
or breakout
cables of up to 24 bers
Cat 5e Unshielded
Cat 6 Unshielded
Cat 6A Unshielded
Cat 5e Shielded
Cat 6 Shielded
Cat 6A Shielded
Cat 7 Shielded
Accessories
Pigtails 1 pack of 12 pigtails,
900 micron, 0.6 m in
12 different colours:
SC/UPC SM 9/125, OS2
SC/PC MM 62.5/125,
OM1
SC/PC MM 50/125,
OM2
SC/PC MM 50/125,
OM3
SC/PC MM 50/125,
OM4
1 pack of 12 pigtails,
900 micron, 0.6 m in
12 different colours:
LC/UPC SM 9/125, OS2
LC/PC MM 62.5/125,
OM1
LC/PC MM 50/125,
OM2
LC/PC MM 50/125,
OM3
LC/PC MM 50/125,
OM4
2 packs of 12 pigtails,
900 micron, 0.6 m in
12 different colours:
SC/UPC SM 9/125, OS2
SC/PC MM 62.5/125,
OM1
SC/PC MM 50/125,
OM2
SC/PC MM 50/125,
OM3
SC/PC MM 50/125,
OM4
2 packs of 12 pigtails,
900 micron, 0.6 m in
12 different colours:
LC/UPC SM 9/125, OS2
LC/PC MM 62.5/125,
OM1
LC/PC MM 50/125,
OM2
LC/PC MM 50/125,
OM3
LC/PC MM 50/125,
OM4

Home
4 1.717.217.2299 www.belden.com/hirschmann
19 Rackmount Patch Panels from Belden
FiberExpress Patch Panels
Features and Benets: Rugged and compact solution for eld termination and fusion splices, all front access.
Description Part No.
Rack Mount, 1U (capacity 2 adapter strips) AX100041
Rack Mount, 4U (capacity: 8 adapter strips) AX100116
Wall Mount, Small (capacity: 2 adapter strips) AX100495
Wall Mount, Medium (capacity: 4 adapter strips) AX100540
Adapter Strips for FiberExpress Patch Panels
Description Multimode Singlemode
LC Duplex, 12 bers AX101729 AX101731
LC Duplex, 24 bers AX101741 AX100538
SC Simplex, 6 bers AX100092 AX100538
SC Duplex, 6 bers AX100094 AX101407
SC Simplex, 12 bers AX100084 AX100532
SC Duplex, 12 bers AX100098 AX101409
KeyConnect Coupler Patch Panel CAT 6+ (Preloaded)
Description Part No.
24-port, 1U, Black AX104227
48-port, 2U, Black AX104228
KeyConnect Patch Panel CAT 6+ (Preloaded)
Description Part No.
24 port, 1U AX103253
48 port, 2U AX103255
Modular Connector Termination Tool
Description Part No.
GIGAFLEX CONNECTION TOOL &110 AX100749
AX100116, FiberExpress 48/96 Port (4U) Rack-mount
Patch Panel
AX101729, Adapters loaded with 6 LC Duplex
Home
5
Be Certain with Belden
www.belden.com/hirschmann 1.717.217.2299
Fiber Connectivity Solutions
Brilliance Field-Installable Connectors and Installation Kits
Features and Benets:
Fast and Easy to install, no epoxy, no polishing, re-usable, complete installation kit with instruction video.
Description
Multimode OM1, 62.5m Multimode OM2, 50 m Singlemode, OS2
1 per package 25 per package 1 per package 25 per package 1 per package 25 per package
LC 900 m Tight Buffer AX104240-S1 AX104240-B25 AX104241-S1 AX104241-B25 AX104243-S1 AX104243-B25
SC 900 m Tight Buffer AX104244-S1 AX104244-B25 AX104245-S1 AX104245-B25 AX104247-S1 AX104247-B25
Installation Kits
Description Part No.
Basic Installation Kit (Pouch, Support Handle, Installation Guide, Video) AX104268
Field Installation Kit (Basic Kit, Fiber Preparation Tools, Field Cleaver and Visual Fault Locator) AX104270
Precision Installation Kit (Basic Kit, Fiber Preparation Tools, Precision Cleaver and Visual Fault Locator) AX104271
Belden offers a variety of Fiber Connectivity Solutions to insure the right connection is made
between Ethernet switches and other end devices. These solutions include feld-installable
connectors and installation kits, patch panels and adapter strips, feld breakout kits and, fber
pigtails and patchcords..
Field Breakout Kits
For eld termination of loose tube ber cable.
Description Part No.
6 bers, 1/pack AX101100
12 bers, 1/pack AX101101
Fiber Pigtails
8 in. trays are for FX Rack Mount 1U and small Wall Mount only
Description
Multimode
62.5 m OM1
Multimode
50 m OM2
Singlemode
OS2-UPC
LC- OPEN, 2 m (6 ft), Simplex 900 m Tight buffer AX200657 AX200658 AX200659
SC- OPEN, 2 m (6 ft), Simplex 900 m Tight buffer 70101714 AX200192 AX200147
Fiber Patch Cords
Description
Multimode
62.5 m OM1
Multimode
50 m OM2
Singlemode
OS2-UPC
LC Duplex - LC Duplex, 2 m (6 ft), Duplex Zip Cord 2.0 mm AX200517 AX200527 AX200507
LC Duplex - LC Duplex, 3 m (10 ft), Duplex Zip Cord 2.0 mm AX200518 AX200528 AX200508
SC Duplex - SC Duplex, 2 m (6 ft), Duplex Zip Cord 3.0 mm AX200056 AX200084 AX203908
SC Duplex - SC Duplex, 3 m (10 ft), Duplex Zip Cord 3.0 mm AX200057 AX200082 AX202523
ST - ST 2 m (6 ft), Duplex Zip Cord 3.0 mm 70102419 AX200341 AX200200
ST - ST 3 m (10 ft), Duplex Zip Cord 3.0 mm 70102420 AX200459 AX202089
AX104271, Precision Installation Kit
AX101100, Field Breakout Kit, 6 bers, 1 pack
AX200507, FiberExpress Duplex Patch Cord, LC Duplex - LC
Duplex, Single-mode, UPC
Home
6 1.717.217.2299 www.belden.com/hirschmann
Industrial Ethernet Media Cord Sets, Cat5e - Bonded Pair
TPE - Bonded-Pair, CAT 5e, 24 AWG Unshielded, 2- and 4-Pair
Part No. Conguration Description
J424TPESTJT...M RJ45 to RJ45 Industrial Ethernet CAT 5E, TPE unshielded, 2- and 4-pair, 24 AWG cable,
bonded-pairs, stranded (7x32) tinned copper conductors, polyolen insulation,
and industrial grade sunlight and oil-resistant, teal jacket.
M224TPESTJT...M RJ45 to M12
M224TPESTMT...M M12 to M12
J224TPESTPT...M RJ45 to M12 (Panel Receptacle)
Example of completed part number: J424TPESTJT00.3M is a 00.3 meter cable.
TPE High-Flex - Bonded-Pair, CAT 5e, 24 AWG Unshielded, 2- and 4-Pair
Part No. Conguration Description
J424THFSTJT...M RJ45 to RJ45 Industrial Ethernet High-Flex CAT 5E, TPE High-Flex, unshielded, 2-and 4 pair, 24
AWG cable, stranded copper alloy conductors, polyolen insulation, teal jacket.
Warranted to 10 million ex cycles @ 20X OD and 1M ex cycles @ 10X OD.
M224THFSTJT...M RJ45 to M12
M224THFSTMT...M M12 to M12
J224THFSTPT...M RJ45 to M12 (Panel Receptacle)
Example of completed part number: J424THFSTJT00.3M is a 00.3 meter cable.
PVC - Bonded-Pair, CAT 5e, 24 AWG Unshielded, 2- and 4-Pair
Part No. Conguration Description
J424PVCSTJT...M RJ45 to RJ45 Industrial Ethernet CAT 5E, PVC unshielded, 2- and 4-pair, 24 AWG cable,
bonded-pairs, stranded (7x32) tinned copper conductors, polyolen insulation,
and industrial grade sunlight and oil-resistant, teal jacket.
M224PVCSTJT...M RJ45 to M12
M224PVCSTMT...M M12 to M12
J224PVCSTPT...M RJ45 to M12 (Panel Receptacle)
Example of completed part number: J424PVCSTJT00.3M is a 00.3 meter cable.
TPE - Bonded-Pair, CAT 5e, 24 AWG Shielded, 2-Pair
Part No. Conguration Description
J224TPETLJT...M RJ45 to RJ45 Industrial Ethernet CAT 5E, TPE Shielded, 2-pair, 24 AWG cable, bonded-pairs,
stranded (7x32) tinned copper conductors, polyolen insulation, and industrial
grade sunlight and oil-resistant, teal jacket.
M224TPETLJT...M RJ45 to M12
M224TPETLMT...M M12 to M12
J224TPETLPT...M RJ45 to M12 (Panel Receptacle)
Example of completed part number: J224TPETLJT00.3M is a 00.3 meter cable.
TPE High-Flex - Bonded-Pair, CAT 5e, 24 AWG Shielded, 2- and 4-Pair
Part No. Conguration Description
J424THFTLJT...M RJ45 to RJ45 Industrial Ethernet CAT 5E, TPE, High-Flex shielded, 2- and 4-pair, 24 AWG cable,
bonded-pairs, stranded (7x32) tinned copper conductors, polyolen insulation,
and industrial grade sunlight and oil-resistant, teal jacket.
M224THFTLJT...M RJ45 to M12
M224THFTLMT...M M12 to M12
J224THFTLPT...M RJ45 to M12 (Panel Receptacle)
Example of completed part number: J424THFTLJT00.3M is a 00.3 meter cable.
Prior to the advent of Industrial Ethernet (standardized Ethernet communications via hardened
networking infrastructure), offce grade Ethernet cabling and connectors were the only available
options. Unfortunately, these traditional media solutions proved unable to withstand the harsh
environment of the factory foor or other industrial applications.
The Hirschmann product family of Industrial Ethernet Media Solutions eliminates these issues
by combining standard RJ45 connection technology with the proven industrial Micro (M12)
connection technology typically found in sensor/actuator machine applications - also available on
all OCTOPUS, MICE, and MACH1000 Switches.
With the integration of Bonded-Pair technology by Belden, these industrial ethernet media cord
sets have the highest level of signal quality making them one-of-a-kind..
Home
7
Be Certain with Belden
www.belden.com/hirschmann 1.717.217.2299
J 2 24 PVC ST J T 00.3M
Connector Type 1
J = RJ45
M = M12
Number of Conductors (Pairs)
2 = 2 pair
4 = 4 pair
Wire Gauge
24 = 24 AWG cable
Cable Type
PVC = PVC cable type - Bonded-Pair
TPE = TPE cable type - Bonded-Pair
THF = TPE High-Flex cable type - Bonded-Pair
Stranding/Shielding
ST = Stranded, Unshielded
TL = Stranded, Shielded
Connector Type 2
J = RJ45
M = M12
P = M12 Panel Mount Receptacle
Cable Jacket Color
T = Teal
B = Black*
G = Grey*
R = Red*
U = Blue*
N = Orange*
Cable Lengths
00.3M = 0.3 meters 10.0M = 10 meters 60.0M = 60 meters
00.5M = 0.5 meters 12.0M = 12 meters 65.0M = 65 meters
01.0M = 1 meter 15.0M = 15 meters 70.0M = 70 meters
02.0M = 2 meters 20.0M = 20 meters 75.0M = 75 meters
03.0M = 3 meters 25.0M = 25 meters 80.0M = 80 meters
04.0M = 4 meters 30.0M = 30 meters 90.0M = 90 meters
05.0M = 5 meters 40.0M = 40 meters
06.0M = 6 meters 50.0M = 50 meters
07.0M = 7 meters 55.0M = 55 meters
* Denotes special order. Minimum quantaties apply.
Industrial Ethernet Media Cord Set Congurator
Hirschmann by Belden
RJ45 to RJ45 RJ45 to M12 M12 to M12 RJ45 to M12 (Panel Receptacle)
Home
8 1.717.217.2299 www.belden.com/hirschmann
DataTuff

Industrial Ethernet Cord Sets (RJ45). Cat 6 4-Pair,


23 AWG Heavy Duty Oil- & Sunlight-Resistant Black Jackets
IP67 interface complies with the specication (IEC 61076-3-106 Variant 1)
DataTuff Industrial Ethernet Ruggedized Cord Sets with Metal Body (RJ45). Cat6
4-Pair, 23 AWG Heavy Duty Oil- & Sunlight-Resistant, Black Jackets
Unshielded with Solid Conductors (ref: Belden Bonded-Pair Cable 7940A)
Cabling Rating NEC: CMR, CMX-Outdoor CEC: CMR FT4.
Shielded with Solid Conductors (ref: Belden Bonded-Pair Cable 7953A)
Cabling Rating NEC: CMR, CMX-Outdoor CEC: CMR FT4.
Unshielded with Solid Conductors (ref: Belden Bonded-Pair Cable 7940A)
Cable Rating NEC: CMR, CMX-Outdoor CEC: CMR FT4.
Shielded with Solid Conductors (ref: Belden Bonded-Pair Cable 7953A)
Cable Rating NEC: CMR, CMX-Outdoor CEC: CMR FT4.
Belden Part No. IP Rating Length meters (Ft.) Tethered Cap Package Quantity
E600001 010S1 IP67 1 m (3.3 ft.) Yes 1
E600002 010S1 IP67 2 m (6.6 ft.) Yes 1
E600003 010S1 IP67 3 m (9.8 ft.) Yes 1
E600005 010S1 IP67 5 m (16.4 ft.) Yes 1
E600025 010S1 IP67 25 m (82 ft.) Yes 1
E601001 010S1 IP20 1 m (3.3 ft.) 1
E601002 010S1 IP20 2 m (6.6 ft.) 1
E601003 010S1 IP20 3 m (9.8 ft.) 1
E601005 010S1 IP20 5 m (16.4 ft.) 1
Belden Part No. IP Rating Length meters (Ft.) Tethered Cap Package Quantity
E604001 010S1 IP67 1 m (3.3 ft.) Yes 1
E604002 010S1 IP67 2 m (6.6 ft.) Yes 1
E604003 010S1 IP67 3 m (9.8 ft.) Yes 1
E604005 010S1 IP67 5 m (16.4 ft.) Yes 1
E604025 010S1 IP67 25 m (82 ft.) Yes 1
E605001 010S1 IP20 1 m (3.3 ft.) 1
E605002 010S1 IP20 2 m (6.6 ft.) 1
E605003 010S1 IP20 3 m (9.8 ft.) 1
E605005 010S1 IP20 5 m (16.4 ft.) 1
Belden Part No. IP Rating Length meters (Ft.) Tethered Cap Package Quantity
R601001 010S1 IP20 1 m (3.3 ft.) 1
R601002 010S1 IP20 2 m (6.6 ft.) 1
R601003 010S1 IP20 3 m (9.8 ft.) 1
R601005 010S1 IP20 5 m (16.4 ft.) 1
Belden Part No. IP Rating Length meters (Ft.) Tethered Cap Package Quantity
R605001 010S1 IP20 1 m (3.3 ft.) 1
R605002 010S1 IP20 2 m (6.6 ft.) 1
R605003 010S1 IP20 3 m (9.8 ft.) 1
R605005 010S1 IP20 5 m (16.4 ft.) 1
Home
9
Be Certain with Belden
www.belden.com/hirschmann 1.717.217.2299
DataTuff Industrial Ethernet Cord Sets (RJ45). Cat 5e 4-Pair,
24 AWG Heavy Duty Oil- & Sunlight-Resistant Black Jackets
IP67 interface complies with the specication (IEC 61076-3-106 Variant 1)
Unshielded with Solid Conductors (ref: Belden Bonded-Pair Cable 7923A)
Cable Rating NEC: CMR, CMX-Outdoor CEC: CMR FT4. MSHA
Unshielded with Stranded Conductors (ref: Belden Bonded-Pair Cable 7924A)
Cable Rating NEC: CMR, CMX-Outdoor CEC: CMR FT4
Shielded with Solid Conductors (ref: Belden Bonded-Pair Cable 7953A)
Cable Rating NEC: CMR, CMX-Outdoor CEC: CMR FT4.
Belden Part No. IP Rating Length meters (Ft.) Tethered Cap Package Quantity
E500001 010S1 IP67 1 m (3.3 ft.) Yes 1
E500002 010S1 IP67 2 m (6.6 ft.) Yes 1
E500003 010S1 IP67 3 m (9.8 ft.) Yes 1
E500005 010S1 IP67 5 m (16.4 ft.) Yes 1
E500025 010S1 IP67 25 m (82 ft.) Yes 1
E501001 010S1 IP20 1 m (3.3 ft.) 1
E501002 010S1 IP20 2 m (6.6 ft.) 1
E501003 010S1 IP20 3 m (9.8 ft.) 1
E501005 010S1 IP20 5 m (16.4 ft.) 1
Belden Part No. IP Rating Length meters (Ft.) Tethered Cap Package Quantity
E502001 010S1 IP67 1 m (3.3 ft.) Yes 1
E502002 010S1 IP67 2 m (6.6 ft.) Yes 1
E502003 010S1 IP67 3 m (9.8 ft.) Yes 1
E502005 010S1 IP67 5 m (16.4 ft.) Yes 1
E502025 010S1 IP67 25 m (82 ft.) Yes 1
E503001 010S1 IP20 1 m (3.3 ft.) 1
E503002 010S1 IP20 2 m (6.6 ft.) 1
E503003 010S1 IP20 3 m (9.8 ft.) 1
E503005 010S1 IP20 5 m (16.4 ft.) 1
Belden Part No. IP Rating Length meters (Ft.) Tethered Cap Package Quantity
E506001 010S1 IP67 1 m (3.3 ft.) Yes 1
E506002 010S1 IP67 2 m (6.6 ft.) Yes 1
E506003 010S1 IP67 3 m (9.8 ft.) Yes 1
E506005 010S1 IP67 5 m (16.4 ft.) Yes 1
E506025 010S1 IP67 25 m (82 ft.) Yes 1
E507001 010S1 IP20 1 m (3.3 ft.) 1
E507002 010S1 IP20 2 m (6.6 ft.) 1
E507003 010S1 IP20 3 m (9.8 ft.) 1
E507005 010S1 IP20 5 m (16.4 ft.) 1
Home
10 1.717.217.2299 www.belden.com/hirschmann
Modular Jacks (RJ45). Cat 6. IP67
IP67 interface complies with the specication (IEC 61076-3-106 Variant 1)
Modular Jacks (RJ45). Cat 5e. IP67
IP67 interface complies with the specication (IEC 61076-3-106 Variant 1)
Plug Kits (RJ45). Cat 5e. IP67
IP67 interface complies with the specication (IEC 61076-3-106 Variant 1)
Surface Mount Boxes. IP67
Surface Mount Box Dimensions: 12.8 x 12.8 x 6.7 cm deep (5.05 x 5.05 x 2.625 deep)
Field-Installable Metal Body Ruggedized Plug (RJ45). Cat 6. IP20
Stainless Steel Faceplates. IP67
Tools
Belden Part No. Description Tethered Cap Package Quantity
E100601 010S1 UTP, Black Yes 1
E100602 010S1 FTP, Black Yes 1
Belden Part No. Description Tethered Cap Package Quantity
E100501 010S1 UTP, Black Yes 1
E100502 010S1 FTP, Black Yes 1
Belden Part No. Description Tethered Cap Package Quantity
E300501 010S1 UTP, Black Yes 1
E300502 010S1 FTP, Black Yes 1
Belden Part No. Description Package Quantity
E200101 009S1 1-port, White/Stainless Steel Cover 1
E200102 009S1 2-port, White/Stainless Steel Cover 1
E200103 009S1 3-port, White/Stainless Steel Cover 1
E200104 009S1 4-port, White/Stainless Steel Cover 1
Belden Part No. Description Package Quantity
R301601 000S1 UTP/STP, T568A Plug 1
R301602 000S1 UTP/STP, T568B Plug 1
Belden Part No. Description Package Quantity
E200001 000S1 Single gang, 1-port 1
E200002 000S1 Single gang, 2-port 1
E200004 000S1 Double gang, 4-port 1
Belden Part No. Description Package Quantity
E200001 000S1 Hand tool to crimp unshielded (UTP) and shielded (FTP) RJ45 plugs. Black with Blue handle 1
E200001 000S1 Cable stripper, Gray 1
E200002 000S1 Punch-down connecting tool 1
E200004 000S1 Punch-down connecting tool pouch 1
Home
11
Be Certain with Belden
www.belden.com/hirschmann 1.717.217.2299
Belden DataTuff
Connectivity Solutions
Belden DataTuff Connectivity products are
built specifcally for use in mission-critical and
harsh environments. They include:
Cord Sets (RJ45)
Cat 6 or Cat 5e UTP or FTP with solid 24
AWG conductors and industrial-grade
sunlight/oil resistant jackets. Suitable for use
in IP67 or IP20 installations.
Modular Jacks (RJ45)
Cat 6 or Cat 5e for UTP or FTP. Suitable for
use in IP67 installations.
Plug Kits (RJ45)
Cat 5e UTP or FTP. Suitable for use in IP67
installations.
Metal Body Field-Installable Plug
Cat6 UTP or FTP.
Belden DataTuff
Cabling Accessories
Belden offers industrial-grade faceplates and
surface mount boxes:
Stainless Steel Faceplates
1- or 2-Port single-gang or 4-Port double-
gang. Suitable for use in IP67 installations.
Surface Mount Boxes
1-, 2-, 3-, or 4-Port with Stainless Steel
Covers. Suitable for use in IP67 installations.
Belden DataTuff Tools
Belden provides the following easy-to-use,
highly durable tools:
Crimping Hand Tool
1- or 2-Port single-gang or 4-Port double-
gang. Suitable for use in IP67 installations.
Cable Strippers (Blue)
(Black with Blue handle) that crimps either
UTP or FTP RJ45 plugs.
Punch Down Connecting Tool
and Punch
Hirschmann Standard
D-coded M12 Connectors
IP67 Cord Set
IP20 Cord Set
IP67 Modular
Jack
IP67 Stainless
Steel Faceplates
Crimping Tool
Punch-down
Connecting
Tool
IP67
Plug Kit
IP67 Surface
Mount Box
Stripping Tool
Metal Body
Field-Installable
Plug
Field attachable Industrial ETHERNET M12
connector D-coded according
IEC 61076-2-101.
Type Order no. Contacts
EM12S OCTOPUS 934 445-001 4
Industrial ETHERNET M12 socket, D-coded
according IEC 61076-2-101 mounting thread
with connection leads.
Type Order no. Contacts
EF12M OCTOPUS 934 450-021 4
Bulkhead M12 connector D-coded according
IEC 61076-2-101 Amendment 1 to RJ45.
Type Order no. Contacts
EF12RJ45 OCTOPUS 934 498-001 4
Industrial ETHERNET M12 socket, D-coded
according IEC 61076-2-101 for combined front
panels and circuit board installation
Type Order no. Contacts
EF12LW OCTOPUS 934 451-521 4
EF12L OCTOPUS 934 451-021 4
Home
Hirschmann Ethernet Cables Quick Look
Part Number Length Stock Levels Part Number Length Stock
J424TPETXJT02.0M 2M Trend M224THFSTMN00.3M 0.3M Trend
J424TPETXJT03.0M 3M Trend M224THFSTMN00.5M 0.5M Trend
J424TPETXJT04.0M 4M Trend M224THFSTMN01.0M 1M Trend
J424TPETXJT05.0M 5M Trend M224THFSTMN02.0M 2M Trend
M224THFSTMN03.0M 3M Trend
M224THFSTMN04.0M 4M Trend
M224THFSTMN05.0M 5M Trend
M224THFSTMN06.0M 6M Trend
M224THFSTMN07.0M 7M Trend
M224THFSTMN10.0M 10M Trend
M224THFSTMN12.0M 12M Trend
Part Number Length Stock Levels M224THFSTMN15.0M 15M Trend
J424TPESTJU00.3M 0.3M 50 M224THFSTMN20.0M 20M Trend
J424TPESTJU00.5M 0.5M 50 M224THFSTMN25.0M 25M Trend
J424TPESTJU01.0M 1M 50 M224THFSTMN30.0M 30M Trend
J424TPESTJU02.0M 2M 30 M224THFSTMN40.0M 40M Trend
J424TPESTJU03.0M 3M 20 M224THFSTMN50.0M 50M Trend
J424TPESTJU04.0M 4M Trend
J424TPESTJU05.0M 5M Trend
Part Number Length Stock
M224TPESTMU00.3M 0.3M Trend Part Number Length Stock
M224TPESTMU00.5M 0.5M 10 P224THFSTPN02.0M 2M Trend
M224TPESTMU01.0M 1M 25 P224THFSTPN03.0M 3M Trend
M224TPESTMU02.0M 2M 50 P224THFSTPN04.0M 4M Trend
M224TPESTMU03.0M 3M 25 P224THFSTPN05.0M 5M Trend
M224TPESTMU04.0M 4M Trend P224THFSTPN06.0M 6M Trend
M224TPESTMU05.0M 5M 20 P224THFSTPN07.0M 7M Trend
Patch Cables / In Panel RJ45 to RJ45
Patch Cables / External Cabinet Cables / Device to Device M12 to M12
M12(Male) -M12(Male), Blue TPE, Stranded, Unshielded, 24AWG, 2-pair
M12(Male) - M12(Male), Orange TPE, Continuous High Flex Stranded, Unshielded, 24AWG, 2-pair
RJ45(Male) - RJ45(Male), Blue TPE, Stranded, Unshielded, 24AWG, 4-pair
HI FLEX Patch Cables / External Cabinet Cables / Device to Device M12 to M12 - ORANGE
M12 recept(Female) - M12 recept(Female), Orange TPE, Continuous High Flex Stranded, Unshielded, 24AWG, 2-pair
HI FLEX Extension Cables - ORANGE
Programming Cables / Crossover RJ45 to RJ45
RJ45(Male) - RJ45(Male), Teal TPE, Stranded Crossover, Unshielded, 24AWG, 4-pair
M224TPESTMU05.0M 5M 20 P224THFSTPN07.0M 7M Trend
M224TPESTMU06.0M 6M Trend P224THFSTPN10.0M 10M Trend
M224TPESTMU07.0M 7M 5 P224THFSTPN12.0M 12M Trend
M224TPESTMU10.0M 10M 30 P224THFSTPN15.0M 15M Trend
M224TPESTMU12.0M 12M Trend P224THFSTPN20.0M 20M Trend
M224TPESTMU15.0M 15M 30 P224THFSTPN25.0M 25M Trend
M224TPESTMU20.0M 20M 30 P224THFSTPN30.0M 30M Trend
M224TPESTMU25.0M 25M 20
M224TPESTMU30.0M 30M 20
M224TPESTMU40.0M 40M Trend
M224TPESTMU50.0M 50M Trend
M224TPESTMU60.0M 60M Trend Part Number Type Stock
M224TPESTMU70.0M 70M Trend
M224TPESTMU80.0M 80M Trend
Part Number Length Stock
J224TPESTPU00.3M 0.3M 20
J224TPESTPU00.5M 0.5M 50
J224TPESTPU01.0M 1M 50
J224TPESTPU02.0M 2M 50
J224TPESTPU03.0M 3M 10
Note: Typically stock is
Blue, TPE jacketed, unshielded
Hi Flex cable is Orange, TPE jacketed, unshielded
Patch to Bulk Head Connector RJ45 to M12
RJ45(Male) -M12(Female), Blue TPE, Stranded, Unshielded, 24AWG, 2-pair Panduit
HLM, HLS, HLT
Hirschmann
EF12RJ45OCTOPUS
RJ45 to
Bulk head M12
Converter
Trend
Accessories
Trend
Velcro
Cable
Ties
Home
Ethernet Part Numbers: (Terminations)
Rockwell Products:
1732E-xxx (M12)
1734-AENT, AENTR (RJ45)
1738-AENT, AENTR (RJ45)
1756-ENBT (RJ45)
1756-EN2T, EN2TR (RJ45)
1763-Lxxx (RJ45)
1766-Lxxx (RJ45)
1768-ENBT (RJ45)
1769-L23E (RJ45)
1769-L32E (RJ45)
1769-L35E (RJ45)
1783-xxx (RJ45)
1791ES-xxx (RJ45)
1794-AENT (RJ45)
20CommE (RJ45)
22CommE (RJ45)
2711C-T6x, T10x (RJ45)
2711PC-xxx (RJ45)
2711-xxxx20 (RJ45)
2711P-xxxx20x (RJ45)
93xx-xxxx - Programming Software
Hirschmann Products:
Spiderxx (RJ45)
Octopusxxx (M12)
RS20xxx (RJ45)
RS30xxx (RJ45)
J424TPESTJU00.3M
J424TPESTJU00.3M
Jacket
PVC
TPE
THF = HI Flex
Part Number Key
Connectors
J = RJ45
M= M12 (Male)
J424TPESTJU00.3M
Number of Pair
2 = 2 Pair
4 = 4 Pair
Wire Guage
J424TPESTJU00.3M
Type of Wire
SO = Solid
ST = Stranded
TX = Stranded/Crossover Cable
T = Teal
N = Orange
U = Blue
Connectors
J424TPESTJU00.3M
24 Guage
J424TPESTJU00.3M
J424TPESTJU00.3M
Length in Meters
J = RJ45
M = M12 Male
P = Panel Bulk Head (Female)
J424TPESTJU00.3M
Cable Color
Home

Back to Overview
Home Products Plugs & jacks for cabling RJ 45 Plugs Products



E-DAT Industry RJ 45 field plug black Cat.6 Class EA

multi-port Cat.6 class EA plug to be assembled in the field
compliance with class EA to ISO/IEC 11801 Ed.2.2:2011-06, DIN EN 50173-1:2011-09
10 GBit suitable according to IEEE 802.3an
8-wire RJ 45 plug for AWG 22 to be assembled in the field
connection of AWG 26/7 - 22/7; AWG 24/1 - 22/1 possible
solid copper wire diameter from 0.4 to 0.64 mm
stranded copper wire diameter from 0.48 to 0.76 mm
conductor diameter up to 1.6 mm
cable jacket from 5.5 to 8.5 mm
consists of only 2 parts
easy assembly - connection without special tools
during mounting, the cable is mechanically fastened to the stuffer cap
easy to actuate strain relief
strain relief can be snapped on after assembly as color coding
zinc die-cast housing for industrial use
protected locking hook
can be used as test plug on IP67 protected jacks of variants 1, 4, 5, 6 and 14






Technical Data
Accessory
Downloads
P/N 1401405012-I
Color black
Feature 1 8(8) field plug

Feature 2 two parts

EAN-No 4250184113881
Home
B.92 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.
PHYSICAL INFRASTRUCTURE SYSTEMS
A.
System
Overview
B.
Copper
Systems
C.
Fiber
Optic
Systems
D.
Power
over
Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
RJ45 Jack Blockout Device
Blocks unauthorized access to jacks and potentially
harmful foreign objects, saving time and money
associated with data security breaches, network
downtime, repair and hardware replacement
Compatible with most RJ45 jacks to accommodate a
variety of applications and does not interfere with
jack contacts
Can be installed/removed without interfering with adjacent
jacks or hardware
May only be released with the special removal tool,
ensuring the safety and security of your
network infrastructure
PSL-DCJB
*Available in bulk packages of 100 devices and five removal tools. To order bulk package add -C to the suffix of
part number.
Part Number Part Description Color
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
PSL-DCJB* Package of ten RJ45 jack blockout devices and one
removal tool.
Red 1 20
PSL-DCJB-BL* Package of ten RJ45 jack blockout devices and one
removal tool.
Black 1 20
PSL-DCJB-BU* Package of ten RJ45 jack blockout devices and one
removal tool.
Blue 1 20
PSL-DCJB-YL* Package of ten RJ45 jack blockout devices and one
removal tool.
Yellow 1 20
PSL-DCJB-IW* Package of ten RJ45 jack blockout devices and one
removal tool.
International
White
1 20
PSL-DCJB-GR* Package of ten RJ45 jack blockout devices and one
removal tool.
Green 1 20
PSL-DCJB-OR* Package of ten RJ45 jack blockout devices and one
removal tool.
Orange 1 20
PSL-DCJB-IG* Package of ten RJ45 jack blockout devices and one
removal tool.
International
Gray
1 20
PSL-DCJB-VL* Package of ten RJ45 jack blockout devices and one
removal tool.
Violet 1 20
Home
B.93 www.panduit.com For service and technical support, call 866-405-6654 (outside the U.S. and Canada, see back cover).
A.
System
Overview
B.
Copper
Systems
C.
Fiber
Optic
Systems
D.
Power
over
Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
PHYSICAL INFRASTRUCTURE SYSTEMS
USB Blockout Device
Blockout devices block unauthorized access to USB ports,
to provide additional security from viruses being loaded
and illicit data being removed through the USB port
Type A blockouts compatible with USB 2.0 and USB 3.0
Type A ports; Type B blockouts compatible with USB 2.0
Type B ports
Can be installed without interfering with adjacent
USB ports
May only be released with the special removal tool,
ensuring the safety and security of your network
infrastructure; Permanent blockouts are not releasable
PSL-DCJBUSBA
Part Number Part Description Color
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
USB Type A Blockouts
PSL-USBA* Package of five USB Type A blockout devices
and one removal tool.
Red 1 20
PSL-PERM-USBA Package of ten Permanent USB Type A
blockout devices.
Red 1 20
USB Type B Blockouts
PSL-USBB Package of ten USB Type B blockout devices
and one removal tool.
Red 1 20
PSL-PERM-USBB Package of ten Permanent USB Type B
blockout devices.
Red 1 20
PSL-DCJBPERM-USBA
PSL-DCJBUSBB
PSL-DCJBPERM-USBB
*Available in bulk packages of 50 devices and five removal tools. To order bulk package add -L to the suffix
of part number.
Home
B.94 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.
PHYSICAL INFRASTRUCTURE SYSTEMS
A.
System
Overview
B.
Copper
Systems
C.
Fiber
Optic
Systems
D.
Power
over
Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
RJ45 Plug Lock-In Device
Tamper-resistant design blocks unauthorized removal
of cable, VoIP phone, other networking equipment, or
critical connection
Compatible with UTP and shielded Category 6A, 6,
and UTP Category 5e patch cords
Deters unauthorized users from moving or stealing
VoIP phones helping to maintain E911 service
Compact design does not interfere with adjacent jack
modules, even in high-density applications
Installation/removal tool allows plug to be locked into or
released from jack module for enhanced physical security
Locking mechanism is white for flush mount and clear
for recessed devices
*Available in bulk packages of 100 devices and five installation/removal tools. To order bulk package add -C to the
suffix of part number. The RJ45 plug lock-in device may not be compatible with all jacks, overmolded cables, or
PanView

Cables.
Part Number Part Description Color
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
Flush Compatible With Flush Mounted Jack Modules
PSL-DCPLX* Package of ten RJ45 plug lock-in devices and one
installation/removal tool.
Red 1 20
PSL-DCPLX-BL* Package of ten RJ45 plug lock-in devices and one
installation/removal tool.
Black 1 20
PSL-DCPLX-BU* Package of ten RJ45 plug lock-in devices and one
installation/removal tool.
Blue 1 20
PSL-DCPLX-YL* Package of ten RJ45 plug lock-in devices and one
installation/removal tool.
Yellow 1 20
PSL-DCPLX-IW* Package of ten RJ45 plug lock-in devices and one
installation/removal tool.
International
White
1 20
PSL-DCPLX-GR* Package of ten RJ45 plug lock-in devices and one
installation/removal tool.
Green 1 20
PSL-DCPLX-OR* Package of ten RJ45 plug lock-in devices and one
installation/removal tool.
Orange 1 20
PSL-DCPLX-IG* Package of ten RJ45 plug lock-in devices and one
installation/removal tool.
International
Gray
1 20
PSL-DCPLX-VL* Package of ten RJ45 plug lock-in devices and one
installation/removal tool.
Violet 1 20
Recessed Compatible With Recessed Jack Modules
PSL-DCPLRX* Package of ten recessed RJ45 plug lock-in
devices and one installation/removal tool.
Red 1 20
PSL-DCPLRX-BL* Package of ten recessed RJ45 plug lock-in
devices and one installation/removal tool.
Black 1 20
PSL-DCPLRX-BU* Package of ten recessed RJ45 plug lock-in
devices and one installation/removal tool.
Blue 1 20
PSL-DCPLRX-YL* Package of ten recessed RJ45 plug lock-in
devices and one installation/removal tool.
Yellow 1 20
PSL-DCPLRX-IW* Package of ten recessed RJ45 plug lock-in
devices and one installation/removal tool.
International
White
1 20
PSL-DCPLRX-GR* Package of ten recessed RJ45 plug lock-in
devices and one installation/removal tool.
Green 1 20
PSL-DCPLRX-OR* Package of ten recessed RJ45 plug lock-in
devices and one installation/removal tool.
Orange 1 20
PSL-DCPLRX-IG* Package of ten recessed RJ45 plug lock-in
devices and one installation/removal tool.
International
Gray
1 20
PSL-DCPLRX-VL* Package of ten recessed RJ45 plug lock-in
devices and one installation/removal tool.
Violet 1 20
PPSL-DCPLRX-BL
Home



E-DAT Industry IP67 Cable Coupler

RJ 45 termination unit E-DAT modul in flange housing to ISO/IEC 24702 and IEC 61076-3-
106 var. 6
certified to GHMT Cat.6 de-embedded PVP
compliance with class EA to ISO/IEC 11801 Ed.2.2:2011-06, DIN EN 50173-1:2011-09
10 GBit suitable according to IEEE 802.3an
suitable for Power over Ethernet (PoE, PoE plus and UPoE)
easy to install connection of 2 to 4-pair data lines AWG 24/1 - 22/1 and stranded wires with
7 copper conductors AWG 26/7 to BTR 8-fold insulation displacement connectors (IDC)
complies with ingress protection IP67 when plugged in
plug face pursuant to IEC 61076-3-106 (variant 6)
large 360 shield contact
can be used as cable coupler (KK)
connection of RJ 45 plugs available on the market (no IP protection)
easy, time-saving mounting
color: RAL 7035 (light gray)






Technical Data


Downloads
P/N 1309415003-E
Color light gray
Feature 1 8(8) Modul T568A
Feature 2 cable coupler
EAN-No 4250184106579
Home




E-DAT Industry IP67 plug

Cat.6 class EA connector in connector housing to IEC 61076-3-106 var. 6
compliance with class EA to ISO/IEC 11801 Ed.2.2:2011-06, DIN EN 50173-1:2011-09
10 GBit suitable according to IEEE 802.3an
suitable for Power over Ethernet (PoE, PoE plus and UPoE)
complies with ingress protection IP67 when plugged in
AWG 27/7 - 24/7 and AWG 24/1 connection possible
solid copper wire diameter from 0.36 to 0.51 mm
stranded copper wire diameter from 0.46 to 0.61 mm
conductor diameter from 0.85 to 1.05 mm
cable jacket up to 7.3 mm can be connected
large 360 shield contact
locking clip can also be upgraded in its installed state
protected against unintentional opening by means of locking clip (also colored)
crimping of the internal and external conductors with professional crimp pliers in one
process
professional crimping tool available in the tools section






Technical Data
Accessory
Downloads
P/N 130906-03-E
Color light gray
Feature 1 8(8)
Feature 2

EAN-No 4250184105381
Home



E-DAT Industry IP67 8(8) AP Cat.6

RJ 45 termination unit E-DAT module in flange housing to ISO/IEC 24702 and IEC 61076-3-
106 var. 6
certified to GHMT Cat.6 de-embedded PVP
compliance with class EA to ISO/IEC 11801 Ed.2.2:2011-06, DIN EN 50173-1:2011-09
10 GBit suitable according to IEEE 802.3an
suitable for Power over Ethernet (PoE and PoE plus)
easy to install connection of 2 to 4 pair data lines AWG 24/1 - 22/1 and stranded wires with
7 copper conductors AWG 26/7 to BTR 8-fold insulation displacement connectors (IDC)
complies with ingress protection IP67 when plugged in
plug face pursuant to IEC 61076-3-106 (Variant 6)
large 360 shield contact
possible surface-mounting in series (AP)
connection of RJ 45 plugs available on the market (no IP protection)
easy, time-saving mounting
color: light gray RAL 7035






Technical Data


Downloads
P/N 1309410003-E
Color light gray
Feature 1 8(8) Modul T568A
Feature 2 Surface mount
EAN-No 4250184106517
Home






Modul REGplus IP20 light gray unequipped

unequipped termination unit for mounting on TH35 rail to DIN EN 60715
for one individual module in Modul design
variable cable feed 45 from the top or bottom, plug direction 45 downwards
width of 1HP allows mounting up to 12 REG in standard electrical distribution panels
when mounted as a device of protection class I, the equipotential bonding is realized
directly over the rail by means of an integrated equipotential plate. Special measures have to
be taken to integrate the rail in the equipotential bonding of the building.
a cover protects the device against direct contact. If mounted in distributor panels with
protective insulation, protection class II is guaranteed. In this case, it is necessary to remove
the equipotential bonding plate.
integrated dust protection cover (also colored)
suitable modules for cable access 45 from the top: C6Amodul 180, E-DAT modul 8(8), E-
DAT modul coupler 180, UAE modul Cat.5e and Cat.6, OpDAT modul LC-D and ST, coax
modules and E2000 DC couplers
suitable modules for cable access 45 from the bottom: C6Amodul 270 and E-DAT modul
coupler 90
not suitable for modules in Keystone design and C6A modul 90!






Technical Data


Downloads
P/N 1309427103-E
Color light gray
Feature 1 1 port unequipped

Feature 2 BTR cut-out

EAN-No 4250184136538
Home
Goes Where
Other Cables
Fear to Go
Ethernet for Harsh Environment
Rugged. Reliable. Trusted to Eliminate Downtime.
Learn more about DataMax

Extreme
Contact Quabbins Sales Service Department at
1-800-368-3311 or Sales@quabbin.com
www.quabbin.com/harsh
Quabbin Wire and Cable Co., Inc., 10 Maple Street, Ware, MA 01082
800.368.3311 413.967.6281 fax 413.967.7564 www.quabbin.com
Ethernet for harsh environment
Rugged. Reliable. Trusted to Eliminate Downtime.
MECHANICAL TESTING
The purpose behind mechanical testing is to manipulate and work the
cable in a manner that duplicates real world scenarios and determine if
it will continue to perform at the required standards. If a cable is being
used in a continuous movement application its important that it be
able to bend and flex repeatedly without compromising the integrity
of the design. Quabbins in house testing facilities can replicate these
movements and evaluate each cable to provide realistic information
and data to extrapolate performance expectations in the field. To
the right are two images, the first is showing a Torsion tester which
simulates a rotational stress comparable to what a cable would
experience while controlling end of arm tooling. The second photo
shows a rolling bend Flex tester which simulates an unsupported
bending motion typical of what you would see on a robotic arm.
CHEMICAL TESTING
Quabbins harsh environment cables find their way into many
interesting applications such as mil-tec, wastewater treatment and
energy exploration, just to name a few. Historically the most popular
application for Industrial Ethernet has been on the factory floor an
environment also regarded as harsh not only due to mechanical
abuse, but also because of chemical exposure. This knowledge has
guided us to test cable capabilities beyond electrical and mechanical
stress and evaluate performance and longevity when faced with
chemicals and solvents. To the right is a picture illustrating the
chemical testing performed on our industrial Ethernet cables. The tests
include prolonged exposure to a battery of chemicals and the resultant
effect on tensile, elongation, diameter and wall thickness as well as
overall characteristic changes.
What advances DataMax

to the next level earning the name DataMax

Extreme? The section below


outlines the intense testing that isnt required by any formal standard, but is performed as part of the
Quabbin

quality commitment. You need a cable you can be tough on and trust in a harsh environment.
We need to provide you with the evidence that our cable is the best choice for the job.
Chemical tests (affectionately nicknamed the bean sprout
tests) being conducted to validate the resistance of the
TPE (thermoplastic elastomer) cable jacket to chemicals
commonly found in a heavy manufacturing environment such
as cutting fluid, oil and robotic grease.
Rolling Bend Flex Tester showing a 4 pair, double shielded
(foil & braid), DataMax

Extreme with Non Halogen TPU


jacket being tested to 10 million cycles. Results were a cable
with no physical damage that continued to surpass category
5e test parameters.
Torsion tests were
performed on Quabbin 2 pair
UTP industrial Ethernet cable
and Quabbin 4 pair double
shielded cable. The 34 test
sample was subjected to a
360 degree twist per cycle
(180 in each direction).
Three Million cycles were
completed on each design
with no apparent physical
degradation and the cable
continued to exceed
electrical performance
specifications.
2-PAIR FR-TPE CABLE
Return Loss Return Loss
Near-end Crosstalk Near-end Crosstalk
4-PAIR FR-TPE CABLE
ELECTRICAL TESTING
When you choose Quabbin

cable you are not only selecting a premier industrial Ethernet


cable, but you are also investing in productivity and peace of mind. Quabbin

is dedicated to
producing best of breed cables for the industrial market. We achieve this through constant
innovation, in-line monitoring and rigorous testing ensuring our cables meet your needs,
requirements and expectations. We know the importance of mitigating downtime and our top
priority is to deliver a cable you can depend on in any environment. For complete test reports
visit the lab section of our website or contact a Quabbin

sales representative.
Transmitting 10Base-T, 100Base-T, or Gigabit Ethernet
signals over distances in an industrial application presents
two challenges. Building a cable or cord assembly is only
half of the battle. The other challenge is, How good is
it electrically? The charts below illustrate typical Return
Loss and Near End Crosstalk performance for DataMax


Extreme 2-pair and 4-pair, 24 AWG FR-TPE jacketed
cables. Note the huge performance headroom compared
to Category 5e requirements. Industrial Grade PVC or
Polyurethane jacketed DataMax

Extreme cables also


exceed Category 5e limits. Use DataMax

Extreme cables
to ensure that your Industrial Ethernet cords comply
with applicable requirements of both the TIA 568-C.2
commercial and TIA 1005 industrial specifications.
8.12
Home
Ethernet for Harsh Environment
Rugged. Reliable. Trusted to Eliminate Downtime. minate Do ntime gged. Reliable. Trusted to Elim Ru R minate Downtime. gg
Hi-flex Unshielded
with Separator Tape
Overall Foil Shield
with Drain Wire
Double Shield: Foil,
Drain Wire, Braid
Hi-flex Double Shield:
Foil, Braid
LISTINGS/RATINGS
AVAILABLE
UL 1685
VW-1
CM
CMR
CMX
CMX Outdoor
600V AWM
PLTC
Non-proprietary Ethernet offers a huge increase in signaling
speeds over older industrial control systems. Ethernet is
reliable and easily migrates from 10Base-T to higher speeds.
However, commercial office Ethernet systems cannot survive
harsh conditions on the factory floor
without being specially hardened
or protected.
Quabbins family of Industrial Ethernet
cables were developed to reliably
survive industrial hazards and may
be terminated using encapsulated
RJ- 45 modular plugs or industrial M12 connectors which
have been adapted for Ethernet transmission. These
connectors use O-rings, overmolding, and/or sealing gaskets
to bond to the cable jackets, providing a mated connection
that resists fluids, dust, vibration, and
other hazards, yet often may be field
assembled. Assembly ratings of IP67
and IP69 are achievable when properly
terminated using sealed connectors,
assuring resistance to both fluid and
dust particle penetration.
INDUSTRIAL ETHERNET (IE) APPLICATION
CABLE CONSTRUCTION OPTIONS
DataMax

Extreme cables are available in a variety of


constructions. All four cable jacket options can be applied
to 2-pair or 4-pair unshielded designs with 24 AWG or 22
AWG stranded conductors. Shielded designs are also offered
in 2 or 4-pair and four available jackets using 26 AWG
stranded conductors to maintain a consistent product line
OD. Operational environment usually determines if shielded
cable must be considered, however Quabbins unshielded
cable pairs have exceptional balance that provides a high
degree of isolation from EMI and other emissions. Due to
the outstanding balance, many customers have found they
can use unshielded cables where they thought they needed
shielded. This can be a critical performance advantage
since unshielded cables typically have a longer flex life than
shielded cables.
PRESSURE EXTRUDED JACKETS
DataMax

Extreme jackets are pressure extruded over


the cable core, effectively locking the pairs in place. This
provides very stable electrical performance, even when
the cable is impacted, bent, or repeatedly flexed. Pressure
extrusion also provides a very smooth, round jacket that
aids termination and sealing.
Cable jackets protect the cable core from environmental,
operational, and installation hazards. The DataMax

Extreme
jackets were developed to survive many of the industrial
hazards that commercial jackets will not. Compare the
performance characteristics of the four optional compounds
used for cable jacketing in the chart below.
DATAMAX

EXTREME JACKET COMPARISON INFORMATION


Performance Criteria Industrial
PVC
FR-TPE TPU Halogen-
free TPU
Low Cost Construction Excellent Good Fair Fair
RoHS Compliant and Lead Free Yes Yes Yes Yes
Dielectric Strength and
Electrical Performance
Good Good Fair Fair
Low Temperature Flexibility
and Brittle Point
Fair Excellent Excellent Excellent
Tear Resistance Fair Good Excellent Excellent
Abrasion and Scuff Resistance Good Good Excellent Excellent
Flexibility and Flex-Life Fair Excellent Excellent Excellent
Tensile Strength and Toughness Good Good Excellent Excellent
Resistance to Ozone Excellent Good Good Good
Ultraviolet and Weather Resistance Fair Excellent Good Good
Resistance to Acids Fair Good Fair Fair
Resistance to Bases Good Good Good Good
Resistance to Moisture Good Excellent Excellent Excellent
Resistance to Petrochemicals Good Good/Excellent Fair Fair
Flame and Fire Resistance Excellent Good/Excellent Fair Excellent
Jackets include industrial-grade
PVC, flame retardant thermoplastic
elastomer (FR-TPE), polyurethane
(TPU), and halogen-free polyurethane.
You can see that no single jacket
compound is optimum in all
characteristics. Since there is no
single best jacket for all applications,
contact Quabbins Sales Service
Department at 1-800-368-3311 or
Sales@quabbin.com to help determine
the proper compound that provides
the optimum balance of electrical,
mechanical, and cost considerations
for your project.
DataMax

Extreme Industrial Ethernet Patch Cable


Superior construction and design ensures DataMax

Extreme Industrial
Ethernet cables possess all of the characteristics necessary to withstand
harsh environments while performing above industry standards for signal
transmission. The result is a family of cable products that fully comply with
TIA 568-C.2 commercial and TIA 1005 industrial communication specifications,
while reducing downtime and increasing productivity.
APPLICATIONS
Factory Automation
Robotic Control
Machine Vision
Food and Beverage
Oil & Gas
Mil-tec
Energy
Transportation
Harsh Environments
DESIGN OPTIONS
22, 24, & 26 AWG tinned copper
2 or 4 pair (similar diameter allows shared tooling)
Unshielded, foil shield w/drain, and foil shield w/braid
PVC, FR TPE, TPU, or Halogen Free TPU Jacket
Flexible or continuous flex
Weld spatter resistant
Chemical/oil resistant
RoHS compliant
UV resistant
Depicted at left are the
various 4 pair cable
constructions. Each design
is also available in a similar 2
pair configuration. For guidance
on selecting the perfect cable
to fit your needs, please
contact the Quabbin Sales/
Service department.
DATAMAX

EXTREME INDUSTRIAL ETHERNET PART NUMBERS (Partial listing see catalog for all part numbers)
Encapsulated RJ-45 Industrial M12
LEARN MORE 800.368.3311 www.quabbin.com/harsh
Q
u
a
b
b
i
n

P
a
r
t

N
u
m
b
e
r
C
o
l
o
r
N
u
m
b
e
r

o
f

P
a
i
r
s
A
W
G
U
n
s
h
i
e
l
d
e
d
F
o
i
l

S
h
i
e
l
d

&

B
r
a
i
d
C
M


I
n
c
l
u
d
e
s

U
L

1
6
8
5
C
M
X

O
u
t
d
o
o
r
C
M
X


I
n
c
l
u
d
e
s

V
W
-
1
6
0
0
V

A
W
M
P
L
T
C
C
o
n
t
i
n
u
o
u
s

F
l
e
x
H
a
l
o
g
e
n

F
r
e
e
W
e
l
d

S
p
a
t
t
e
r

R
e
s
i
s
t
a
n
t
P
l
u
g

T
o

P
l
u
g

M
a
x

L
e
n
g
t
h
N
o
m
i
n
a
l

C
a
b
l
e

D
i
a
m
e
t
e
r

i
n
c
h
e
s
/
m
m
All DataMax

Extreme Industrial Ethernet cables are chemical resistant and RoHS compliant
STRANDED, FR-TPE JACKET
5770 Black 2 24 AWG 85 meters .230"/5.84mm
5772 Teal 2 24 AWG 85 meters .230"/5.84mm
5750 Black 4 24 AWG 85 meters .248"/6.30mm
5752 Teal 4 24 AWG 85 meters .248"/6.30mm
5900 Black 2 22 AWG 100 meters .270"/6.86mm
5902 Teal 2 22 AWG 100 meters .270"/6.86mm
5800 Black 4 22 AWG 100 meters .295"/7.49mm
5802 Teal 4 22 AWG 100 meters .295"/7.49mm
5085 Black 2 26 AWG 68 meters .225"/5.72mm
5087 Teal 2 26 AWG 68 meters .225"/5.72mm
5083 Black 4 26 AWG 68 meters .244"/6.20mm
5088 Teal 4 26 AWG 68 meters .244"/6.20mm
5089 Black 4 24 AWG 90 meters .301"/7.65mm
5090 Teal 4 24 AWG 90 meters .301"/7.65mm
SOLID, FR-TPE JACKET
5774 Teal 2 24 AWG 100 meters .225"/5.72mm
9415 Teal 4 24 AWG 100 meters .240"/6.10mm
STRANDED, TPU JACKET
5000 Black 2 24 AWG 70 meters .220"/5.59mm
5016 Teal 2 24 AWG 70 meters .220"/5.59mm
5700 Black 4 24 AWG 70 meters .228"/5.79mm
5716 Teal 4 24 AWG 70 meters .228"/5.79mm
5020 Black 2 22 AWG 82 meters .270"/6.86mm
5022 Teal 2 22 AWG 82 meters .270"/6.86mm
5120 Black 4 22 AWG 82 meters .276"/7.01mm
5122 Teal 4 22 AWG 82 meters .276"/7.01mm
5080 Black 2 26 AWG PENDING 68 meters .225"/5.72mm
5082 Teal 2 26 AWG PENDING 68 meters .225"/5.72mm
5075 Black 4 26 AWG PENDING 68 meters .244"/6.20mm
5077 Teal 4 26 AWG PENDING 68 meters .244"/6.20mm
5730 Black 4 26 AWG 68 meters .220"/5.59mm
5732 Teal 4 26 AWG 68 meters .220"/5.59mm
Home
Ethernet for Harsh Environment
Rugged. Reliable. Trusted to Eliminate Downtime. minate Do ntime gged. Reliable. Trusted to Elim Ru R minate Downtime. gg
Hi-flex Unshielded
with Separator Tape
Overall Foil Shield
with Drain Wire
Double Shield: Foil,
Drain Wire, Braid
Hi-flex Double Shield:
Foil, Braid
LISTINGS/RATINGS
AVAILABLE
UL 1685
VW-1
CM
CMR
CMX
CMX Outdoor
600V AWM
PLTC
Non-proprietary Ethernet offers a huge increase in signaling
speeds over older industrial control systems. Ethernet is
reliable and easily migrates from 10Base-T to higher speeds.
However, commercial office Ethernet systems cannot survive
harsh conditions on the factory floor
without being specially hardened
or protected.
Quabbins family of Industrial Ethernet
cables were developed to reliably
survive industrial hazards and may
be terminated using encapsulated
RJ- 45 modular plugs or industrial M12 connectors which
have been adapted for Ethernet transmission. These
connectors use O-rings, overmolding, and/or sealing gaskets
to bond to the cable jackets, providing a mated connection
that resists fluids, dust, vibration, and
other hazards, yet often may be field
assembled. Assembly ratings of IP67
and IP69 are achievable when properly
terminated using sealed connectors,
assuring resistance to both fluid and
dust particle penetration.
INDUSTRIAL ETHERNET (IE) APPLICATION
CABLE CONSTRUCTION OPTIONS
DataMax

Extreme cables are available in a variety of


constructions. All four cable jacket options can be applied
to 2-pair or 4-pair unshielded designs with 24 AWG or 22
AWG stranded conductors. Shielded designs are also offered
in 2 or 4-pair and four available jackets using 26 AWG
stranded conductors to maintain a consistent product line
OD. Operational environment usually determines if shielded
cable must be considered, however Quabbins unshielded
cable pairs have exceptional balance that provides a high
degree of isolation from EMI and other emissions. Due to
the outstanding balance, many customers have found they
can use unshielded cables where they thought they needed
shielded. This can be a critical performance advantage
since unshielded cables typically have a longer flex life than
shielded cables.
PRESSURE EXTRUDED JACKETS
DataMax

Extreme jackets are pressure extruded over


the cable core, effectively locking the pairs in place. This
provides very stable electrical performance, even when
the cable is impacted, bent, or repeatedly flexed. Pressure
extrusion also provides a very smooth, round jacket that
aids termination and sealing.
Cable jackets protect the cable core from environmental,
operational, and installation hazards. The DataMax

Extreme
jackets were developed to survive many of the industrial
hazards that commercial jackets will not. Compare the
performance characteristics of the four optional compounds
used for cable jacketing in the chart below.
DATAMAX

EXTREME JACKET COMPARISON INFORMATION


Performance Criteria Industrial
PVC
FR-TPE TPU Halogen-
free TPU
Low Cost Construction Excellent Good Fair Fair
RoHS Compliant and Lead Free Yes Yes Yes Yes
Dielectric Strength and
Electrical Performance
Good Good Fair Fair
Low Temperature Flexibility
and Brittle Point
Fair Excellent Excellent Excellent
Tear Resistance Fair Good Excellent Excellent
Abrasion and Scuff Resistance Good Good Excellent Excellent
Flexibility and Flex-Life Fair Excellent Excellent Excellent
Tensile Strength and Toughness Good Good Excellent Excellent
Resistance to Ozone Excellent Good Good Good
Ultraviolet and Weather Resistance Fair Excellent Good Good
Resistance to Acids Fair Good Fair Fair
Resistance to Bases Good Good Good Good
Resistance to Moisture Good Excellent Excellent Excellent
Resistance to Petrochemicals Good Good/Excellent Fair Fair
Flame and Fire Resistance Excellent Good/Excellent Fair Excellent
Jackets include industrial-grade
PVC, flame retardant thermoplastic
elastomer (FR-TPE), polyurethane
(TPU), and halogen-free polyurethane.
You can see that no single jacket
compound is optimum in all
characteristics. Since there is no
single best jacket for all applications,
contact Quabbins Sales Service
Department at 1-800-368-3311 or
Sales@quabbin.com to help determine
the proper compound that provides
the optimum balance of electrical,
mechanical, and cost considerations
for your project.
DataMax

Extreme Industrial Ethernet Patch Cable


Superior construction and design ensures DataMax

Extreme Industrial
Ethernet cables possess all of the characteristics necessary to withstand
harsh environments while performing above industry standards for signal
transmission. The result is a family of cable products that fully comply with
TIA 568-C.2 commercial and TIA 1005 industrial communication specifications,
while reducing downtime and increasing productivity.
APPLICATIONS
Factory Automation
Robotic Control
Machine Vision
Food and Beverage
Oil & Gas
Mil-tec
Energy
Transportation
Harsh Environments
DESIGN OPTIONS
22, 24, & 26 AWG tinned copper
2 or 4 pair (similar diameter allows shared tooling)
Unshielded, foil shield w/drain, and foil shield w/braid
PVC, FR TPE, TPU, or Halogen Free TPU Jacket
Flexible or continuous flex
Weld spatter resistant
Chemical/oil resistant
RoHS compliant
UV resistant
Depicted at left are the
various 4 pair cable
constructions. Each design
is also available in a similar 2
pair configuration. For guidance
on selecting the perfect cable
to fit your needs, please
contact the Quabbin Sales/
Service department.
DATAMAX

EXTREME INDUSTRIAL ETHERNET PART NUMBERS (Partial listing see catalog for all part numbers)
Encapsulated RJ-45 Industrial M12
LEARN MORE 800.368.3311 www.quabbin.com/harsh
Q
u
a
b
b
i
n

P
a
r
t

N
u
m
b
e
r
C
o
l
o
r
N
u
m
b
e
r

o
f

P
a
i
r
s
A
W
G
U
n
s
h
i
e
l
d
e
d
F
o
i
l

S
h
i
e
l
d

&

B
r
a
i
d
C
M


I
n
c
l
u
d
e
s

U
L

1
6
8
5
C
M
X

O
u
t
d
o
o
r
C
M
X


I
n
c
l
u
d
e
s

V
W
-
1
6
0
0
V

A
W
M
P
L
T
C
C
o
n
t
i
n
u
o
u
s

F
l
e
x
H
a
l
o
g
e
n

F
r
e
e
W
e
l
d

S
p
a
t
t
e
r

R
e
s
i
s
t
a
n
t
P
l
u
g

T
o

P
l
u
g

M
a
x

L
e
n
g
t
h
N
o
m
i
n
a
l

C
a
b
l
e

D
i
a
m
e
t
e
r

i
n
c
h
e
s
/
m
m
All DataMax

Extreme Industrial Ethernet cables are chemical resistant and RoHS compliant
STRANDED, FR-TPE JACKET
5770 Black 2 24 AWG 85 meters .230"/5.84mm
5772 Teal 2 24 AWG 85 meters .230"/5.84mm
5750 Black 4 24 AWG 85 meters .248"/6.30mm
5752 Teal 4 24 AWG 85 meters .248"/6.30mm
5900 Black 2 22 AWG 100 meters .270"/6.86mm
5902 Teal 2 22 AWG 100 meters .270"/6.86mm
5800 Black 4 22 AWG 100 meters .295"/7.49mm
5802 Teal 4 22 AWG 100 meters .295"/7.49mm
5085 Black 2 26 AWG 68 meters .225"/5.72mm
5087 Teal 2 26 AWG 68 meters .225"/5.72mm
5083 Black 4 26 AWG 68 meters .244"/6.20mm
5088 Teal 4 26 AWG 68 meters .244"/6.20mm
5089 Black 4 24 AWG 90 meters .301"/7.65mm
5090 Teal 4 24 AWG 90 meters .301"/7.65mm
SOLID, FR-TPE JACKET
5774 Teal 2 24 AWG 100 meters .225"/5.72mm
9415 Teal 4 24 AWG 100 meters .240"/6.10mm
STRANDED, TPU JACKET
5000 Black 2 24 AWG 70 meters .220"/5.59mm
5016 Teal 2 24 AWG 70 meters .220"/5.59mm
5700 Black 4 24 AWG 70 meters .228"/5.79mm
5716 Teal 4 24 AWG 70 meters .228"/5.79mm
5020 Black 2 22 AWG 82 meters .270"/6.86mm
5022 Teal 2 22 AWG 82 meters .270"/6.86mm
5120 Black 4 22 AWG 82 meters .276"/7.01mm
5122 Teal 4 22 AWG 82 meters .276"/7.01mm
5080 Black 2 26 AWG PENDING 68 meters .225"/5.72mm
5082 Teal 2 26 AWG PENDING 68 meters .225"/5.72mm
5075 Black 4 26 AWG PENDING 68 meters .244"/6.20mm
5077 Teal 4 26 AWG PENDING 68 meters .244"/6.20mm
5730 Black 4 26 AWG 68 meters .220"/5.59mm
5732 Teal 4 26 AWG 68 meters .220"/5.59mm
Home
Ethernet for Harsh Environment
Rugged. Reliable. Trusted to Eliminate Downtime. minate Do ntime gged. Reliable. Trusted to Elim Ru R minate Downtime. gg
Hi-flex Unshielded
with Separator Tape
Overall Foil Shield
with Drain Wire
Double Shield: Foil,
Drain Wire, Braid
Hi-flex Double Shield:
Foil, Braid
LISTINGS/RATINGS
AVAILABLE
UL 1685
VW-1
CM
CMR
CMX
CMX Outdoor
600V AWM
PLTC
Non-proprietary Ethernet offers a huge increase in signaling
speeds over older industrial control systems. Ethernet is
reliable and easily migrates from 10Base-T to higher speeds.
However, commercial office Ethernet systems cannot survive
harsh conditions on the factory floor
without being specially hardened
or protected.
Quabbins family of Industrial Ethernet
cables were developed to reliably
survive industrial hazards and may
be terminated using encapsulated
RJ- 45 modular plugs or industrial M12 connectors which
have been adapted for Ethernet transmission. These
connectors use O-rings, overmolding, and/or sealing gaskets
to bond to the cable jackets, providing a mated connection
that resists fluids, dust, vibration, and
other hazards, yet often may be field
assembled. Assembly ratings of IP67
and IP69 are achievable when properly
terminated using sealed connectors,
assuring resistance to both fluid and
dust particle penetration.
INDUSTRIAL ETHERNET (IE) APPLICATION
CABLE CONSTRUCTION OPTIONS
DataMax

Extreme cables are available in a variety of


constructions. All four cable jacket options can be applied
to 2-pair or 4-pair unshielded designs with 24 AWG or 22
AWG stranded conductors. Shielded designs are also offered
in 2 or 4-pair and four available jackets using 26 AWG
stranded conductors to maintain a consistent product line
OD. Operational environment usually determines if shielded
cable must be considered, however Quabbins unshielded
cable pairs have exceptional balance that provides a high
degree of isolation from EMI and other emissions. Due to
the outstanding balance, many customers have found they
can use unshielded cables where they thought they needed
shielded. This can be a critical performance advantage
since unshielded cables typically have a longer flex life than
shielded cables.
PRESSURE EXTRUDED JACKETS
DataMax

Extreme jackets are pressure extruded over


the cable core, effectively locking the pairs in place. This
provides very stable electrical performance, even when
the cable is impacted, bent, or repeatedly flexed. Pressure
extrusion also provides a very smooth, round jacket that
aids termination and sealing.
Cable jackets protect the cable core from environmental,
operational, and installation hazards. The DataMax

Extreme
jackets were developed to survive many of the industrial
hazards that commercial jackets will not. Compare the
performance characteristics of the four optional compounds
used for cable jacketing in the chart below.
DATAMAX

EXTREME JACKET COMPARISON INFORMATION


Performance Criteria Industrial
PVC
FR-TPE TPU Halogen-
free TPU
Low Cost Construction Excellent Good Fair Fair
RoHS Compliant and Lead Free Yes Yes Yes Yes
Dielectric Strength and
Electrical Performance
Good Good Fair Fair
Low Temperature Flexibility
and Brittle Point
Fair Excellent Excellent Excellent
Tear Resistance Fair Good Excellent Excellent
Abrasion and Scuff Resistance Good Good Excellent Excellent
Flexibility and Flex-Life Fair Excellent Excellent Excellent
Tensile Strength and Toughness Good Good Excellent Excellent
Resistance to Ozone Excellent Good Good Good
Ultraviolet and Weather Resistance Fair Excellent Good Good
Resistance to Acids Fair Good Fair Fair
Resistance to Bases Good Good Good Good
Resistance to Moisture Good Excellent Excellent Excellent
Resistance to Petrochemicals Good Good/Excellent Fair Fair
Flame and Fire Resistance Excellent Good/Excellent Fair Excellent
Jackets include industrial-grade
PVC, flame retardant thermoplastic
elastomer (FR-TPE), polyurethane
(TPU), and halogen-free polyurethane.
You can see that no single jacket
compound is optimum in all
characteristics. Since there is no
single best jacket for all applications,
contact Quabbins Sales Service
Department at 1-800-368-3311 or
Sales@quabbin.com to help determine
the proper compound that provides
the optimum balance of electrical,
mechanical, and cost considerations
for your project.
DataMax

Extreme Industrial Ethernet Patch Cable


Superior construction and design ensures DataMax

Extreme Industrial
Ethernet cables possess all of the characteristics necessary to withstand
harsh environments while performing above industry standards for signal
transmission. The result is a family of cable products that fully comply with
TIA 568-C.2 commercial and TIA 1005 industrial communication specifications,
while reducing downtime and increasing productivity.
APPLICATIONS
Factory Automation
Robotic Control
Machine Vision
Food and Beverage
Oil & Gas
Mil-tec
Energy
Transportation
Harsh Environments
DESIGN OPTIONS
22, 24, & 26 AWG tinned copper
2 or 4 pair (similar diameter allows shared tooling)
Unshielded, foil shield w/drain, and foil shield w/braid
PVC, FR TPE, TPU, or Halogen Free TPU Jacket
Flexible or continuous flex
Weld spatter resistant
Chemical/oil resistant
RoHS compliant
UV resistant
Depicted at left are the
various 4 pair cable
constructions. Each design
is also available in a similar 2
pair configuration. For guidance
on selecting the perfect cable
to fit your needs, please
contact the Quabbin Sales/
Service department.
DATAMAX

EXTREME INDUSTRIAL ETHERNET PART NUMBERS (Partial listing see catalog for all part numbers)
Encapsulated RJ-45 Industrial M12
LEARN MORE 800.368.3311 www.quabbin.com/harsh
Q
u
a
b
b
i
n

P
a
r
t

N
u
m
b
e
r
C
o
l
o
r
N
u
m
b
e
r

o
f

P
a
i
r
s
A
W
G
U
n
s
h
i
e
l
d
e
d
F
o
i
l

S
h
i
e
l
d

&

B
r
a
i
d
C
M


I
n
c
l
u
d
e
s

U
L

1
6
8
5
C
M
X

O
u
t
d
o
o
r
C
M
X


I
n
c
l
u
d
e
s

V
W
-
1
6
0
0
V

A
W
M
P
L
T
C
C
o
n
t
i
n
u
o
u
s

F
l
e
x
H
a
l
o
g
e
n

F
r
e
e
W
e
l
d

S
p
a
t
t
e
r

R
e
s
i
s
t
a
n
t
P
l
u
g

T
o

P
l
u
g

M
a
x

L
e
n
g
t
h
N
o
m
i
n
a
l

C
a
b
l
e

D
i
a
m
e
t
e
r

i
n
c
h
e
s
/
m
m
All DataMax

Extreme Industrial Ethernet cables are chemical resistant and RoHS compliant
STRANDED, FR-TPE JACKET
5770 Black 2 24 AWG 85 meters .230"/5.84mm
5772 Teal 2 24 AWG 85 meters .230"/5.84mm
5750 Black 4 24 AWG 85 meters .248"/6.30mm
5752 Teal 4 24 AWG 85 meters .248"/6.30mm
5900 Black 2 22 AWG 100 meters .270"/6.86mm
5902 Teal 2 22 AWG 100 meters .270"/6.86mm
5800 Black 4 22 AWG 100 meters .295"/7.49mm
5802 Teal 4 22 AWG 100 meters .295"/7.49mm
5085 Black 2 26 AWG 68 meters .225"/5.72mm
5087 Teal 2 26 AWG 68 meters .225"/5.72mm
5083 Black 4 26 AWG 68 meters .244"/6.20mm
5088 Teal 4 26 AWG 68 meters .244"/6.20mm
5089 Black 4 24 AWG 90 meters .301"/7.65mm
5090 Teal 4 24 AWG 90 meters .301"/7.65mm
SOLID, FR-TPE JACKET
5774 Teal 2 24 AWG 100 meters .225"/5.72mm
9415 Teal 4 24 AWG 100 meters .240"/6.10mm
STRANDED, TPU JACKET
5000 Black 2 24 AWG 70 meters .220"/5.59mm
5016 Teal 2 24 AWG 70 meters .220"/5.59mm
5700 Black 4 24 AWG 70 meters .228"/5.79mm
5716 Teal 4 24 AWG 70 meters .228"/5.79mm
5020 Black 2 22 AWG 82 meters .270"/6.86mm
5022 Teal 2 22 AWG 82 meters .270"/6.86mm
5120 Black 4 22 AWG 82 meters .276"/7.01mm
5122 Teal 4 22 AWG 82 meters .276"/7.01mm
5080 Black 2 26 AWG PENDING 68 meters .225"/5.72mm
5082 Teal 2 26 AWG PENDING 68 meters .225"/5.72mm
5075 Black 4 26 AWG PENDING 68 meters .244"/6.20mm
5077 Teal 4 26 AWG PENDING 68 meters .244"/6.20mm
5730 Black 4 26 AWG 68 meters .220"/5.59mm
5732 Teal 4 26 AWG 68 meters .220"/5.59mm
Home
Goes Where
Other Cables
Fear to Go
Ethernet for Harsh Environment
Rugged. Reliable. Trusted to Eliminate Downtime.
Learn more about DataMax

Extreme
Contact Quabbins Sales Service Department at
1-800-368-3311 or Sales@quabbin.com
www.quabbin.com/harsh
Quabbin Wire and Cable Co., Inc., 10 Maple Street, Ware, MA 01082
800.368.3311 413.967.6281 fax 413.967.7564 www.quabbin.com
Ethernet for harsh environment
Rugged. Reliable. Trusted to Eliminate Downtime.
MECHANICAL TESTING
The purpose behind mechanical testing is to manipulate and work the
cable in a manner that duplicates real world scenarios and determine if
it will continue to perform at the required standards. If a cable is being
used in a continuous movement application its important that it be
able to bend and flex repeatedly without compromising the integrity
of the design. Quabbins in house testing facilities can replicate these
movements and evaluate each cable to provide realistic information
and data to extrapolate performance expectations in the field. To
the right are two images, the first is showing a Torsion tester which
simulates a rotational stress comparable to what a cable would
experience while controlling end of arm tooling. The second photo
shows a rolling bend Flex tester which simulates an unsupported
bending motion typical of what you would see on a robotic arm.
CHEMICAL TESTING
Quabbins harsh environment cables find their way into many
interesting applications such as mil-tec, wastewater treatment and
energy exploration, just to name a few. Historically the most popular
application for Industrial Ethernet has been on the factory floor an
environment also regarded as harsh not only due to mechanical
abuse, but also because of chemical exposure. This knowledge has
guided us to test cable capabilities beyond electrical and mechanical
stress and evaluate performance and longevity when faced with
chemicals and solvents. To the right is a picture illustrating the
chemical testing performed on our industrial Ethernet cables. The tests
include prolonged exposure to a battery of chemicals and the resultant
effect on tensile, elongation, diameter and wall thickness as well as
overall characteristic changes.
What advances DataMax

to the next level earning the name DataMax

Extreme? The section below


outlines the intense testing that isnt required by any formal standard, but is performed as part of the
Quabbin

quality commitment. You need a cable you can be tough on and trust in a harsh environment.
We need to provide you with the evidence that our cable is the best choice for the job.
Chemical tests (affectionately nicknamed the bean sprout
tests) being conducted to validate the resistance of the
TPE (thermoplastic elastomer) cable jacket to chemicals
commonly found in a heavy manufacturing environment such
as cutting fluid, oil and robotic grease.
Rolling Bend Flex Tester showing a 4 pair, double shielded
(foil & braid), DataMax

Extreme with Non Halogen TPU


jacket being tested to 10 million cycles. Results were a cable
with no physical damage that continued to surpass category
5e test parameters.
Torsion tests were
performed on Quabbin 2 pair
UTP industrial Ethernet cable
and Quabbin 4 pair double
shielded cable. The 34 test
sample was subjected to a
360 degree twist per cycle
(180 in each direction).
Three Million cycles were
completed on each design
with no apparent physical
degradation and the cable
continued to exceed
electrical performance
specifications.
2-PAIR FR-TPE CABLE
Return Loss Return Loss
Near-end Crosstalk Near-end Crosstalk
4-PAIR FR-TPE CABLE
ELECTRICAL TESTING
When you choose Quabbin

cable you are not only selecting a premier industrial Ethernet


cable, but you are also investing in productivity and peace of mind. Quabbin

is dedicated to
producing best of breed cables for the industrial market. We achieve this through constant
innovation, in-line monitoring and rigorous testing ensuring our cables meet your needs,
requirements and expectations. We know the importance of mitigating downtime and our top
priority is to deliver a cable you can depend on in any environment. For complete test reports
visit the lab section of our website or contact a Quabbin

sales representative.
Transmitting 10Base-T, 100Base-T, or Gigabit Ethernet
signals over distances in an industrial application presents
two challenges. Building a cable or cord assembly is only
half of the battle. The other challenge is, How good is
it electrically? The charts below illustrate typical Return
Loss and Near End Crosstalk performance for DataMax


Extreme 2-pair and 4-pair, 24 AWG FR-TPE jacketed
cables. Note the huge performance headroom compared
to Category 5e requirements. Industrial Grade PVC or
Polyurethane jacketed DataMax

Extreme cables also


exceed Category 5e limits. Use DataMax

Extreme cables
to ensure that your Industrial Ethernet cords comply
with applicable requirements of both the TIA 568-C.2
commercial and TIA 1005 industrial specifications.
8.12
Home
Goes Where
Other Cables
Fear to Go
Ethernet for Harsh Environment
Rugged. Reliable. Trusted to Eliminate Downtime.
Learn more about DataMax

Extreme
Contact Quabbins Sales Service Department at
1-800-368-3311 or Sales@quabbin.com
www.quabbin.com/harsh
Quabbin Wire and Cable Co., Inc., 10 Maple Street, Ware, MA 01082
800.368.3311 413.967.6281 fax 413.967.7564 www.quabbin.com
Ethernet for harsh environment
Rugged. Reliable. Trusted to Eliminate Downtime.
MECHANICAL TESTING
The purpose behind mechanical testing is to manipulate and work the
cable in a manner that duplicates real world scenarios and determine if
it will continue to perform at the required standards. If a cable is being
used in a continuous movement application its important that it be
able to bend and flex repeatedly without compromising the integrity
of the design. Quabbins in house testing facilities can replicate these
movements and evaluate each cable to provide realistic information
and data to extrapolate performance expectations in the field. To
the right are two images, the first is showing a Torsion tester which
simulates a rotational stress comparable to what a cable would
experience while controlling end of arm tooling. The second photo
shows a rolling bend Flex tester which simulates an unsupported
bending motion typical of what you would see on a robotic arm.
CHEMICAL TESTING
Quabbins harsh environment cables find their way into many
interesting applications such as mil-tec, wastewater treatment and
energy exploration, just to name a few. Historically the most popular
application for Industrial Ethernet has been on the factory floor an
environment also regarded as harsh not only due to mechanical
abuse, but also because of chemical exposure. This knowledge has
guided us to test cable capabilities beyond electrical and mechanical
stress and evaluate performance and longevity when faced with
chemicals and solvents. To the right is a picture illustrating the
chemical testing performed on our industrial Ethernet cables. The tests
include prolonged exposure to a battery of chemicals and the resultant
effect on tensile, elongation, diameter and wall thickness as well as
overall characteristic changes.
What advances DataMax

to the next level earning the name DataMax

Extreme? The section below


outlines the intense testing that isnt required by any formal standard, but is performed as part of the
Quabbin

quality commitment. You need a cable you can be tough on and trust in a harsh environment.
We need to provide you with the evidence that our cable is the best choice for the job.
Chemical tests (affectionately nicknamed the bean sprout
tests) being conducted to validate the resistance of the
TPE (thermoplastic elastomer) cable jacket to chemicals
commonly found in a heavy manufacturing environment such
as cutting fluid, oil and robotic grease.
Rolling Bend Flex Tester showing a 4 pair, double shielded
(foil & braid), DataMax

Extreme with Non Halogen TPU


jacket being tested to 10 million cycles. Results were a cable
with no physical damage that continued to surpass category
5e test parameters.
Torsion tests were
performed on Quabbin 2 pair
UTP industrial Ethernet cable
and Quabbin 4 pair double
shielded cable. The 34 test
sample was subjected to a
360 degree twist per cycle
(180 in each direction).
Three Million cycles were
completed on each design
with no apparent physical
degradation and the cable
continued to exceed
electrical performance
specifications.
2-PAIR FR-TPE CABLE
Return Loss Return Loss
Near-end Crosstalk Near-end Crosstalk
4-PAIR FR-TPE CABLE
ELECTRICAL TESTING
When you choose Quabbin

cable you are not only selecting a premier industrial Ethernet


cable, but you are also investing in productivity and peace of mind. Quabbin

is dedicated to
producing best of breed cables for the industrial market. We achieve this through constant
innovation, in-line monitoring and rigorous testing ensuring our cables meet your needs,
requirements and expectations. We know the importance of mitigating downtime and our top
priority is to deliver a cable you can depend on in any environment. For complete test reports
visit the lab section of our website or contact a Quabbin

sales representative.
Transmitting 10Base-T, 100Base-T, or Gigabit Ethernet
signals over distances in an industrial application presents
two challenges. Building a cable or cord assembly is only
half of the battle. The other challenge is, How good is
it electrically? The charts below illustrate typical Return
Loss and Near End Crosstalk performance for DataMax


Extreme 2-pair and 4-pair, 24 AWG FR-TPE jacketed
cables. Note the huge performance headroom compared
to Category 5e requirements. Industrial Grade PVC or
Polyurethane jacketed DataMax

Extreme cables also


exceed Category 5e limits. Use DataMax

Extreme cables
to ensure that your Industrial Ethernet cords comply
with applicable requirements of both the TIA 568-C.2
commercial and TIA 1005 industrial specifications.
8.12
Home
D
e
v
i
c
e
N
e
t
M
e
d
i
a
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
P
a
n
n
e
l
C
o
n
n
e
c
t
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
I
n
t
r
o
d
u
c
t
i
o
n
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
E
t
h
e
r
n
e
t

M
e
d
i
a
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
7-1
Ethernet Media
Table of Contents
Ethernet Media
Cat. No. Index...................................................................12-1
Cordsets & Patchcords
Cable Spools
Introduction
Patchcords & Field Attachables
RJ45.................................................................................................7-9
M12 Flex-Rated .............................................................................7-10
M12 Receptacle Flex-Rated..........................................................7-12
Unshielded Twisted Pair ..................................................................7-5
Shielded Twisted Pair ......................................................................7-6
600V Ethernet Cable........................................................................7-7
Quick Selection Guide.....................................................................7-2
Introduction......................................................................................7-3
Die-Cast Zinc RJ45 Connector, Variant 1......................................7-14
Thermoplastic RJ45 Connector, Variant 1.....................................7-16
M12 Insulation Displacement Connectors ....................................7-20
M12 to RJ45 Bulkhead Connector ................................................7-22
Home
P
a
n
n
e
l
C
o
n
n
e
c
t
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
I
n
t
r
o
d
u
c
t
i
o
n
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
G
e
n
e
r
a
l
D
e
v
i
c
e
N
e
t
M
e
d
i
a
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
P
a
n
n
e
l
C
o
n
n
e
c
t
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
I
n
t
r
o
d
u
c
t
i
o
n
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
E
t
h
e
r
n
e
t

M
e
d
i
a
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
7-2
Ethernet Media
Quick Selection Guide
1585 Ethernet Cable
Spools
1585J In-Cabinet
Ethernet Media
1585D On-Machine
Ethernet Media
1585B On-Machine
Variant 1
Ethernet Media
1585 Ethernet
Bulkhead Connector
Description
2 and 4 pair, shielded and
unshielded cable
RJ45 cordsets,
patchcords, and field
attachable connectors
IP67 M12 D Code
cordsets, patchcords, and
field attachable connectors
IP67 Variant 1 connectivity
- RJ45 connection with
protective housing
Sealed media based on 4-
pin D-coded micro (M12)
connections
Features
Unshielded - PVC riser,
high-flex TPE, plenum
PVC
Shielded - PVC riser,
high-flex, and halogen-
free PUR, PVC 600V
Available in 2 and 4 pair
Shielded and unshielded
cable types
Rugged strain relief for
secure connection
Available in 2 pair
High-flex cable
Male/female,
straight/right angle
receptacle
Available in diecast zinc
and thermoplastic
Overmolded patchcords
Male and female
Male plug
Female outlet
Female RJ45 to RJ45
coupler
4-pin D-coded M12
Threaded connection
IP67 rating
Rugged durable
construction
Connections
Field attachable RJ45,
M12, Variant 1 connectors
RJ45
M12 D Code
M12 D Code to RJ45
M12 D Code receptacle
to RJ45
Variant 1 - RJ45 with
housing for IP67
applications
M12 RJ45 to D-coded
micro
Available Models
Cable spools for
customized applications
Pre-assembled
patchcords
IDC field attachable
connectors for custom
applications
Pre-assembled
patchcords
IDC field attachable
connectors for custom
applications
Pre-assembled
patchcords
IDC field attachable
connectors for custom
applications
IDC field attachable
connectors
M12 to RJ45 bulkhead
pass-thru
Additional Info See page 7-5 See page 7-9 See page 7-10 See page 7-14 See page 7-22
Home
Ethernet Media
Introduction
7-3
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
48MS MultiSight vision sensors
54RF, 55RF, and 56RF RFID ethernet
control interfaces
As ethernet becomes increasingly utilized in
industrial control, survival of physical media
in rugged or harsh environments is
becoming a necessity. The high speed of
network protocol allows it to be used in
applications where other networks fall
short. EtherNet/IP uses both standard
ethernet and TCP/IP technologies and an
open application layer protocol called the
Control and Information Protocol (CIP). This
is the same application layer used in
DeviceNet and ControlNet networks.
Rockwell Automation Cat5e ethernet cables
are designed to supply a reliable network
connection in harsh surroundings. By
optimizing the balance of twisted pair
conductors inside a robust Thermoplastic
Rockwell Automation M12 to RJ45
bulkhead connectors provide an elegant
transition for network architecture from an
IP20 setting to an IP67 environment. The
adaptor can be used to connect remote
junction boxes or implement an On-
Machine solution with Armor I/O
products.
The Rockwell Automation ethernet media
portfolio provides reliable connectivity to
maintain network integrity and prevent
costly downtime from troubleshooting.
M12 patchcords can be used with the
following sensing products:
Elastomer (TPE) jacket, data is protected
from noise, chemicals, and mechanical
issues to M
3
I
3
C
3
E
3
environmental
protection levels. The cable is available in
RJ45 patchcords for IP20 applications or in
four-pin D-coded M12 patchcords for IP67
applications where high vibration, fluids,
and other contaminants can threaten the
reliability of a network.
M12 D-code field attachable insulation
displacement connectors (IDCs) are
available in both shielded and unshielded
housings with male or female connectors.
Male eight-pin RJ45 connectors are
available in both a crimp termination and a
toolless IDCs for custom cabling.
Home
Ethernet Media
Introduction
7-4
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
Ethernet Architecture Layout
1. RJ45 to RJ45 Patchcord...................7-17
2. M12 to RJ45 Bulkhead Connector ...7-22
3. M12 to M12 Patchcord .......................7-9
4. Stratix Ethernet Switch....................9-1
5. ArmorBlock

Ethernet Media............10-1
6. ArmorPOINT

Ethernet Module......10-13
7. Auxiliary Power Mini Receptacle.......6-60
8. Auxiliary Power Mini Patchcord........6-55
9. Auxiliary Power Mini T-Port ...............6-61
10. DC Micro Patchcord........................3-44
11. M23 Pigtail ....................................3-132
12. DC Micro Distribution Box ..............4-14
13. PowerFlex

Drive Safety
Switch with QD........See Drives catalog
14. MultiSight...........See Sensors catalog
Home
Ethernet Media
Cable Spools
7-5
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
Unshielded Twisted Pair
Description
Specifications
Certifications UL Listed and CEC
Conductor Material Tinned copper stranded
Bend Radius 10 million cycles at 20 x diameter (TPE cable)
Data Rate Up to 1 Gb/s, Cat 5e
Voltage 300V
Cable and Color Code
Two-Pair Four-Pair
White/Orange
Orange
White/Green
Green
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
Features
Four- and eight-conductor styles
Twisted pair unshielded cable types, Cat
5e
Twisted pairs maintain signal balance
through cable to provide high noise
immunity and return loss
Designed to ODVA EtherNet/IP
specifications and ISO IEC 24702
Suitable for high noise environments
M
3
I
3
C
3
E
3
Riser PVC cables used for general
purpose environments
TPE robotic cable used for flex
applications, transmission-tested to 10
million cycles
Plenum PVC cable used for air duct
applications
TPE cable meets channel transmission
performance to 10 million flexes
Product Selection
Jacket
Material Cable Type
No. of
Conductors Jacket Color
Wire Size,
AWG
Nominal Outer
Diameter
Operating
Temperature [C (F)] Cable Rating Cat. No.1
Robotic TPE Unshielded
4 (two pair)
Teal 24
5.6 mm (0.22 in.)
-40+75
( 40+167)
Weld splatter,
sunlight, and oil
resistant; UL CM,
CMX; cUL CM;
Standard TIA 568-
B, high flex rated
1585-C4TB-S100
8 (four pair) 5.84 mm (0.23 in.) 1585-C8TB-S100
Robotic TPE
Unshielded 8 (four pair) Red 24 5.84 mm (0.23 in.)
-40+75
(-40+167)
1585-C8VB-S100
Plenum
UL CMP; cUL
CMP; Standard
TIA 568-B
1585-C8MB-S100
Riser PVC Unshielded 8 (four pair) Teal 24 5.84 mm (0.23 in.)
-40+75
(-40+167)
UL CMR; cUL
CMG; Standard
TIA 568-B
1585-C8PB-S100
1 Replace 100 (100 m) with 300 (300 m) or 600 (600 m) for additional standard cable lengths (example 1585-C4TB-S100 becomes 1585-C4TB-S600).
Rockwell Automations Cat5e shielded and
unshielded cable is designed to supply a
reliable network connection in harsh
surroundings. The high speed data rate
allows more data to be transferred within a
shorter period of time. By optimizing
balance of twisted pair conductors inside a
robust thermoplastic elastomer (TPE)
jacket, data is protected from noise,
chemicals, and mechanical issues to
M
3
I
3
C
3
E
3
environmental protection levels.
Two and four pair TPE robotic flex cable is
available for flex applications reaching 10
million cycles, as well as a riser PVC cable
for standard applications and a plenum
PVC cable for air duct applications. All
ethernet media components are designed
to perform above TIA 568-B.2 and ODVA
ethernet standards. Rockwell Automation's
Bulletin 1585 ethernet cables are optimized
UTP and STP cables in many applications.
Unshielded Ethernet Cable Spool
Home
Ethernet Media
Cable Spools
7-6
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
Shielded Twisted Pair (Foil & Braided Shield)
Description
Features
Specifications
Certifications UL Listed and CEC
Conductor Material Tinned copper stranded
Bend Radius 10 million cycles at 20 x diameter (TPE cable)
Data Rate Up to 1 Gb/s, Cat 5e
Voltage 300V
Cable and Color Code
Two-Pair Four-Pair
White/Orange
Orange
White/Green
Green
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
Four- and eight-conductor styles
Twisted pair shielded cable types, Cat 5e
Twisted pairs maintain signal balance
through cable to provide high noise
immunity and return loss
Designed to ODVA EtherNet/IP
specifications and ISO IEC 24702
Suitable for high noise environments
M
3
I
3
C
3
E
3
Riser PVC cables used for general
purpose environments
PUR robotic cable used for flex
applications, also Halogen-free
600V PVC cable designed to support high
voltage applications
600V On-Machine rated cable for use in a
cable tray shared with high voltage power
cables
Product Selection
Jacket
Material Cable Type
No. of
Conductors Jacket Color
Wire Size,
AWG
Nominal Outer
Diameter
Operating
Temperature [C (F)] Cable Rating Cat. No.1
Riser PVC
Foil and
braided
shield
8 (four pair)
Teal 26
5.84 mm (0.23 in.)
-40+75
(-40+167)
UL CMR; cUL
CMG; TIA-568-B
1585-C8CB-S100
Robotic PUR
4 (two pair)
-40+75
(-40+167)
C(ETL)US TYPE
CMX; TIA 568-B,
Flex rated,
Halogen-Free
1585-C4UB-S100
8 (four pair)
6.2 12 mm (0.244
in.)
-40+75
(-40+167 )
C(ETL)US TYPE
CMX; TIA 568-B,
Flex rated,
Halogen-Free
1585-C8UB-S100
600V PVC 8 (four pair)
Teal
22
8.13 0.38 mm
(0.32 in.)
-20+80
(-4+176 )
(UL) CMX, CMR;
c(UL) CMG; (UL)
PLTC or AWM
2570 80 C 600V;
TIA-568-B
1585-C8HB-S100
Red
8.13 0.38 mm
(0.32 in.)
-20+80
(-4+176 )
(UL) CMX, CMR;
c(UL) CMG; (UL)
PLTC or AWM
2570 80 C 600V;
TIA-568-B
1585-C8EB-S100
1 Replace 100 (100 m) with 300 (300 m) or 600 (600 m) for additional standard cable lengths (example 1585-C4TB-S100 becomes 1585-C4TB-S600).
Rockwell Automations Cat5e shielded and
unshielded cable is designed to supply a
reliable network connection in harsh
surroundings. The high speed data rate
allows more data to be transferred within a
shorter period of time. By optimizing
balance of twisted pair conductors inside a
robust thermoplastic elastomer (TPE)
jacket, data is protected from noise,
chemicals, and mechanical issues to
M
3
I
3
C
3
E
3
environmental protection levels.
Two and four pair polyurethane (PUR)
robotic flex cable and enclosures are
available for flex applications. High voltage,
600V Ethernet cable is available for use in
cable tray with high voltage power cables.
All ethernet media components are
designed to perform above TIA 568-B.2 and
ODVA ethernet standards. Rockwell
Automation's Bulletin 1585 ethernet cables
are optimized UTP and STP cables in many
applications.
Shielded Ethernet Cable Spool
Home
Ethernet Media
Cable Spools
7-7
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
600V Ethernet Cable
Description
Features
Foil and braided shield, PVC, eight
conductor (four pair)
600V PVC cable designed to support high
voltage applications
On-Machine rated cable for use in a cable
tray shared with high voltage power
cables
RJ45 insulation displacement connector
available for field terminations
Specifications
Certifications UL and cUL Listed
Outside Diameter 0.32 0.015 in. (8.13 0.38 mm)
Operating Temperature -20+80 C (-4+176 F)
Cable Rating UL, cUL TYPE CMG; UL PLTC or UL AWM 2570 80C 600V, TIA 568B
Approximate Dimensions
RJ45 IDC Connector
1
2
8
7
1
2
8
7
B
P
C
53.1
(2.09)
Ref
13.9
(0.55)
Ref
View
Shown
with Cap
51.2
(2.02)
Ref
11.68
(0.46)
Ref
6.6
(0.26)
Ref
View
Shown
without Cap
13.8
(0.054)
Ref
29.3
(1.15)
Ref
14.2
(0.56)
Ref
Rockwell Automations Cat5e shielded and
unshielded cable is designed to supply a
reliable network connection in harsh
surroundings. The high speed data rate
allows more data to be transferred within a
shorter period of time. By optimizing
balance of twisted pair conductors inside a
robust TPE jacket, data is protected from
noise, chemicals, and mechanical issues to
M
3
I
3
C
3
E
3
environmental protection levels.
Two and four pair PUR robotic flex cable is
available for flex applications, reaching 10
million cycles, as well as a riser PVC cable
for standard applications. High voltage,
600V ethernet cable is available for use in a
cable tray with high voltage power cables.
All ethernet media components are
designed to perform above TIA 568-B.2 and
ODVA ethernet standards. Rockwell
Automation's Bulletin 1585 ethernet cables
are optimized UTP and STP cables in many
applications.
RJ45 Cordset & Patchcord
RJ45 Cordset600V
Home
Ethernet Media
Cable Spools
7-8
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
600V Ethernet Cable
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
Product Selection
RJ45 Cordset
Jacket
Material Cable Type
No. of
Conductors
Jacket
Color
Wire Size,
AWG
Nominal Outer
Diameter
Operating
Temperature
[C (F)] Cable Rating Cat. No.1
600V PVC
Foil and
braided
shield
8 (four pair)
Teal
22
8.13 0.38 mm
(0.32 in.)
-20+80
(-4+176 )
(UL) CMX, CMR; c(UL)
CMG; (UL) PLTC or AWM
2570 80 C 600V; TIA-568-
B
1585-C8HB-S100
Red 1585-C8EB-S100
1 Replace 100 (100 m) with 300 (300 m) or 600 (600 m) for additional standard cable lengths (example 1585-C4TB-S100 becomes 1585-C4TB-S600).
RJ45 Patchcords
Shielding Cable Type Cat. No.1
Foil and braided shield 8 conductor, teal 600V PVC
1585J-M8HB-2
1585J-M8EB-2
No. of Conductors Jacket Material Cable Type Cable Rating Cat. No.1
8
Teal 600V PVC
Foil and braided shield
(UL) CMX, CMR; c(UL) CMG; (UL) PLTC or
AWM 2570 80 C 600V; TIA-568-B
1585J-M8HBJM-2
Red 600V PVC 1585J-M8EBJM-2
1 Replace -2 (2 m) with 5 (5 m) or 10 (10 m) for additional standard cable lengths.
RJ45 IDC Connector
Insulation Diameter [mm (in.)] Cable Diameter [mm (in.)] Cat. No.
0.851.6 (0.0330.063) 59 (0.1970.354) 1585J-M8CC-SH
Pinout
Color
Code
Face View RJ45 Pinout
8-Pin
1 2 3 4 5 6 7 8
A
8-Pin
1 White/Orange
2 Orange
3 White/Green
4 Blue
5 White/Blue
6 Green
7 White/Brown
8 Brown
TxData +
TxData -
Recv Data +
Unused
Unused
Recv Data -
Unused
Unused
Home
Ethernet Media
Cordsets & Patchcords
7-9
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
RJ45
Features
Flex rated TPE, PVC, and Plenum cables
for various applications
Teal or red cable jacket
Rugged strain relief and latch mechanism
to maintain network integrity
Suitable environments M
1
I
1
C
2
E
2
Specifications
Approximate Dimensions
Certifications UL Listed
Connectors RJ45 Male to RJ45 Male, Cat 6
Cable Type Unshielded 4- and 8-conductor, 24 AWG, Industrial Cat5e
Shielded 8-conductor 26 AWG Industrial Cat5e
Enclosure Type Rating IP20
Nominal Outer Diameter 5.84 mm (0.23 in.)
Operating Temperature [C (F)] -20+60 (-4+140 )
Voltage 300V
Dimensions are in millimeters (inches). Illustrations are not drawn to scale.
Pinout
Example of Cordset Example of Patchcord
Product Selection
Cordset
Patchcords
No. of Conductors Jacket Material Cable Type Cable Rating Cat. No.1
4 Teal high-flex TPE
Unshielded twisted pair
Weld splatter, sun light and oil resistant; UL CMG,
CMX; cUL CMG; Standard TIA 568-B, flex rated
1585J-M4TBJM-2
8
Teal high-flex TPE 1585J-M8TBJM-2
Red high-flex TPE 1585J-M8VBJM-2
Teal Riser PVC UL CMR; cUL CMG; Standard TIA 568-B 1585J-M8PBJM-2
Red Plenum UL CMP; cUL CMP; Standard TIA 568 B 1585J-M8MBJM-2
4 Teal high-flex PUR
Foil and braided shield
C(ETL)US TYPE CMX; TIA 568-B, flex-rated,
halogen-free
1585J-M4UBJM-2
8
Teal Riser, PVC UL CMR; CUR CMG, TIA B 1585J-M8CBJM-2
Teal high-flex PUR
C(ETL)US TYPE CMX; TIA 568-B, flex-rated,
halogen-free
1585J-M8UBJM-2
Teal 600V PVC
(UL) CMX, CMR; c(UL) CMG; (UL) PLTC or AWM
2570 80 C 600V; TIA-568-B
1585J-M8HBJM-2
Red 600V PVC 1585J-M8EBJM-2
1 Replace -2 (2 m) with 5 (5 m) or 10 (10 m) for additional standard cable lengths.
Accessories
Description Cat. No.
RJ45 insulation displacement
connector (IDC)
1585J-M8CC-H
RJ45 crimp connector with
boot
1585J-M8CC-C
One item includes a quantity of 50.
Shielding Cable Type Cat. No.1
Unshielded twisted pair
4 conductor, teal high-flex TPE 1585J-M4TB-2
8 conductor, teal high-flex TPE 1585J-M8TB-2
8 conductor, red high-flex TPE 1585J-M8VB-2
8 conductor, teal riser PVC 1585J-M8PB-2
8 conductor, red plenum PVC 1585J-M8MB-2
Foil and braided shield
8 conductor, teal riser PVC 1585J-M8CB-2
4 conductor, teal high-flex PUR 1585J-M4UB-2
8 conductor, teal high-flex PUR 1585J-M8UB-2
8 conductor, teal 600V PVC 1585J-M8HB-2
8 conductor, red 600V PVC 1585J-M8EB-2
Color
Code
Face View RJ45 Pinout
8-Pin
1 2 3 4 5 6 7 8
A
8-Pin 4-Pin
1 White/Orange
2 Orange
3 White/Green
4 Blue
5 White/Blue
6 Green
7 White/Brown
8 Brown
TxData +
TxData -
Recv Data +
Unused
Unused
Recv Data -
Unused
Unused
1 White/Orange
2 Orange
3 White/Green
4 NA
5 NA
6 Green
7 NA
8 NA
TxData +
TxData -
Recv Data +

Recv Data -

RJ45 Cordset
Home
Ethernet Media
Cordsets & Patchcords
7-10
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
M12 Flex-Rated
Features
Over-molded housing suitable for IP67
applications and harsh industrial
environments where extreme vibration,
shock, chemicals, and temperature are
found
Flex-rated cable (cable must be tied down
and not flexed within six inches of the
connector
Single-ended cordsets can be custom
terminated with one of several field
attachable connectors
Designed to ODVA EtherNet/IP
specifications and ISO IEC 24702, IEC
61918
Twisted pairs maintain signal balance
through cable to provide high noise
immunity and return loss
Suitable for noise environments M
3
I
3
C
3
E
3
Specifications
Approximate Dimensions
Mechanical
Coupling Nut Material Nickel-plated brass
Housing Material Polyurethane (PUR)
Contact Material Gold-plated brass
Cable Type Unshielded Teal TPE, 4-conductor, stranded tinned wire, Industrial Cat5e,
UL Listed, weld splatter, sun light and oil resistant
Cable Diameter [mm (in.)] 5.84 (0.23)
Bend Radius
Electrical
Cable Rating Unshielded: Standard TIA 568-B, flex rated, 24 AWG: UL, CMA, CMX,
cUL and CMG
Shielded: Standard TIA 568-B, flex rated, 26 AWG, halogen-free,
C(ETL)US Type CMX
Environmental
Enclosure Type Rating IP67
Operating Temperature [C (F)] -40+75 (-40+167 )
47 (1.85)
Example of Cordset Example of M12 to M12 Patchcord
Example of M12 to RJ45 Patchcord
Dimensions are in millimeters (inches). Illustrations are not drawn to scale.
4-Pin M12 D-Code Cordset
Home
Ethernet Media
Cordsets & Patchcords
7-11
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
M12 Flex-Rated
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
Pinout
Color
Code
Face View Pinout Face View RJ45 Pinout
4-Pin 8-Pin
3
2 1
4
3
2 1
4
1 2 3 4 5 6 7 8
A
1 White-Orange
2 White-Green
3 Orange
4 Green
8-Pin 4-Pin
1 White/Orange
2 Orange
3 White/Green
4 Blue
5 White/Blue
6 Green
7 White/Brown
8 Brown
TxData +
TxData -
Recv Data +
Unused
Unused
Recv Data -
Unused
Unused
1 White/Orange
2 Orange
3 White/Green
4 NA
5 NA
6 Green
7 NA
8 NA
TxData +
TxData -
Recv Data +

Recv Data -

Product Selection
M12 Cordset
M12 Patchcord
First End Connector Second End Connector Cable Type Cat. No.1
Male M12 D-Code, Straight Flying Leads
Unshielded twisted pair, 4-conductor,
Teal TPE, flex rated
1585D-M4TB-2
Foil and braided shield, 4 conductor,
teal PUR, flex rated, halogen-free
1585D-M4UB-2
M12 to RJ45 Patchcord
First End Connector Second End Connector Cable Type Cat. No.1
Male M12 D-Code, Straight Male M12 D-Code, Straight
Unshielded twisted pair, 4 conductor,
teal TPE, flex rated
1585D-M4TBDM-2
Male M12 D-Code, Right Angle Male M12 D-Code, Right Angle 1585D-E4TBDE-2
Male M12 D-Code, Straight Male M12 D-Code, Right Angle 1585D-M4TBDE-2
Male M12 D-Code, Straight Female M12 D-Code, Straight 1585D-M4TBDF-2
Male M12 D-Code, Straight Male M12 D-Code, Straight
Foil and braided shield, 4 conductor,
teal PUR, flex rated, halogen-free
1585D-M4UBDM-2
Male M12 D-Code, Right Angle Male M12 D-Code, Right Angle 1585D-E4UBDE-2
Male M12 D-Code, Straight Male M12 D-Code, Right Angle 1585D-M4UBDE-2
Male M12 D-Code, Straight Female M12 D-Code, Straight 1585D-M4UBDF-2
First End Connector Second End Connector Cable Type Cat. No.1
Male M12 D-Code RJ45
Unshielded twisted pair, 4 conductor,
teal TPE, flex rated
1585D-M4TBJM-2
Foil and braided shield, 4 conductor,
teal PUR, flex rated, halogen-free
1585D-M4UBJM-2
1 Replace -2 (2 m) with 1 (1 m), 5 (5 m) or 10 (10 m) for additional standard cable lengths.
Accessories
Description Channel Bandwidth Cat. No.
RJ45 insulation displacement
connector (IDC)
Cat. 6 1585J-M8CC-H
RJ45 crimp connector with boot Cat. 5e 1585J-M8CC-C
Qty. = 1 piece.
Qty. = 50 pieces.
Home
Ethernet Media
Cordsets & Patchcords
7-12
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
M12 Receptacle Flex-Rated
Features
Suitable for IP67 applications and harsh
industrial environments where extreme
vibration, shock, chemicals, and
temperature are found
Flex-rated cable (cable must be tied down
and not flexed within six inches of the
connector)
Designed to ODVA EtherNet/IP
specifications and ISO IEC 24702, IEC
61918
Twisted pairs maintain signal balance
through cable to provide high noise
immunity and return loss
M12 D-code receptacle is suitable for
noisy environments M
3
I
3
C
3
E
3
Specifications
Mechanical
Coupling Nut Material Nickel-plated brass
Contact Material Gold-plated brass
Cable Type Unshielded Teal TPE, 4-conductor, stranded tinned wire, Industrial Cat5e,
UL Listed, weld splatter, sun light and oil resistant
Cable Diameter [mm (in.)] 5.84 (0.23)
Mounting Front-mount
Electrical
Cable Rating Unshielded: Standard TIA 568-B, flex rated, 24 AWG: UL, CMA, CMX,
cUL and CMG
Shielded: Standard TIA 568-B, flex rated, 26 AWG, halogen-free,
C(ETL)US Type CMX
Voltage 300V
Environmental
Enclosure Type Rating IP67
Operating Temperature [C (F)] -40+75 (-40+167 )
Approximate Dimensions
Dimensions are in millimeters (inches). Illustrations are not drawn to scale.
39 (1.54)
19.5 (0.77)
x
Length
(see table)
M12
9
(0.35)
Dia.
12
(0.47)
Dia.
8
(0.31)
2
(0.08)
28
(1.1)
7.5
(0.29)
19.5 (0.77)
1.5 (0.06)
5.5 (0.22)
Dia.
2
Dia.
M12 x 1
PG9
20/SW18
Dia.
SW17
G
18 (0.71)
Dia.
G
1
x
2
6
3
M12
PIN PIN
RJ45
1
2
6
3
1
2
4
3
44.2 (1.74)
4-Pin M12 D-Code Receptacle to RJ45
Patchcord
Home
Ethernet Media
Cordsets & Patchcords
7-13
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
M12 Receptacle Flex-Rated
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
Pinout
Face View Pinout (Female) Face View RJ45 Pinout
4-Pin
3
2 1
4
1 2 3 4 5 6 7 8
1 White/Orange
2 White/Green
3 Orange
4 Green
1 White/Orange
2 Orange
3 White/Green
4 Blue
5 White/Blue
6 Green
7 White/Brown
8 Brown
TxData +
TxData -
Recv Data +
Unused
Unused
Recv Data -
Unused
Unused
Product Selection
M12 to RJ45 Patchcord
First End Connector Second End Connector Cable Type Cat. No.1
Female M12 D-Code Receptacle, Front
Mount
RJ45
Unshielded twisted pair, 4-Conductor,
Teal TPE, Flex Rated
1585D-D4TBJM-2
Foil and braided shield, 4 conductor,
teal PUR, flex rated, halogen-free
1585D-D4UBJM-2
1 Replace -2 (2 m) with 1 (1 m), 5 (5 m) or 15 (15 m) for additional standard cable lengths.
Home
Ethernet Media
Patchcords & Field Attachables
7-14
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
Die-Cast Zinc RJ45 Connector, Variant 1
Features
Eight-pin RJ45 connector with protective
die-cast zinc housing
IP67, Cat. 6A
Cable must be tied down within 6 in. of
connector
Resistant to water, dust, moisture,
vibration, temperature extremes,
chemicals, and electromagnetic
interference
Easy to assemble and provides a rugged
connection in harsh environments
Used for On-Machine ethernet
connectivity
Suitable environments M
3
I
3
C
3
E
3
Specifications
Certifications UL Listed and cUL
Mechanical
Contact Material Copper alloy
Housing Material Die-cast zinc
Cable Diameter [mm (in.)] 4.08.0 (0.1570.315)
Electrical
Cable Rating 2226 AWG, 0.400.64 mm (0.0160.025 in.)
Assembly Rating 150V, 1.5 A
Mating Cycles 750
Voltage 300V
Environmental
Enclosure Type Rating IP67
Operating Temperature [C (F)] -40+70 (-40+158 )
Approximate Dimensions
Dimensions are in millimeters (inches). Illustrations are not drawn to scale.
152.4 (6.0)
1-White/Orange
8-Brown
7-White/Brown
6-Green
5-White/Blue
4-Blue
3-White/Green
2-Orange
60.1 (2.37)
30 (1.18)
30
(1.18) Dia.
20
(0.79) Dia.
Variant 1 Connector
Home
Ethernet Media
Patchcords & Field Attachables
7-15
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
Die-Cast Zinc RJ45 Connector, Variant 1
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
Male Housing Female Receptacle
78.74 (3.1)
30.4
(1.2) Dia.
20.1
(0.79)
20.1 (0.79)
For color coding ring
30.0
(1.18)
30.4
(1.2)
47.3 (1.9)
24.6
(1.0) Dia.
30.4
(1.2)
Female to Female Coupler
3.0
(1.2)
35.3 (1.4)
24.6
(1.0) Dia.
30.0
(1.18)
3.0
(1.2)
Product Selection
Field Attachables Die-Cast Zinc Overmolded Patchcord Die-Cast Zinc
Description Cat. No.1
Variant 1 housingmale 1585BZ-M8CC
Variant 1 receptaclefemale 1585BZ-F8CC
Female RJ45 to female RJ45 coupler 1585BZ-F8BF
Male protective cap 1585BZ-MCAP
Female protective cap 1585BZ-FCAP
Descrip-
tion Cable Style
Operating
Temperature [C (F)] Cat. No.1
Variant 1
Male to
Variant 1
Male
Unshielded twisted
pair, TPE robotic,
8 conductor
-25+70
(-13+158 )
1585BX-M8TBBM-2
Foil and braided
shield, PUR,
8 conductor, high-
flex, halogen-free
-40+75
(-40+167 )
1585BX-M8UBBM-2
1 Replace -2 (2 m) with 5 (5 m) or 10 (10 m) for additional standard cable
lengths.
Home
Ethernet Media
Patchcords & Field Attachables
7-16
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
Thermoplastic RJ45 Connector, Variant 1
Features
Eight-pin RJ45 connector with protective
thermoplastic bayonet housing
IP66, IP67, Cat. 5e
Cable must be tied down within 6 in. of
connector
Resistant to water, dust, moisture,
vibration, temperature extremes,
chemicals, and electromagnetic
interference
Easy to assemble and provides a rugged
connection in harsh environments
Used for On-Machine ethernet
connectivity
Suitable environments M
3
I
3
C
3
E
3
Specifications
Approximate Dimensions
Certifications UL Listed and cUL
Mechanical
Contact Material Copper alloy
Housing Material Polybutylene teraphthalate (PBT)
Cable Diameter [mm (in.)] 4.08.0 (0.1570.315)
Electrical
Cable Rating 2226 AWG, 0.400.64 mm (0.160.025 in.)
Assembly Rating 150V, 1.5 A
Voltage 300V
Mating Cycles 750
Environmental
Enclosure Type Rating IP66, IP67, NEMA 6
Operating Temperature [C (F)] -25+75 (-13+167 )
Dimensions are in millimeters (inches). Illustrations are not drawn to scale.
152.4 (6.0)
1-White/Orange
8-Brown
7-White/Brown
6-Green
5-White/Blue
4-Blue
3-White/Green
2-Orange
60.1 (2.37)
30 (1.18)
30
(1.18) Dia.
20
(0.79) Dia.
Variant 1 Connector
Home
Ethernet Media
Patchcords & Field Attachables
7-17
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
Thermoplastic RJ45 Connector, Variant 1
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
Male Housing Female Receptacle
33.9 (1.33)
30.1
(1.19) dia.
32.4
(1.28)
21.1
(0.83)
UTP
Symbol
53.7 (2.11)
Acceptable Cable
4.08.0
(0.1570.315) dia.

33
(1.3) dia.
30
(1.18)
33 (1.3)
13
(0.51)
17
(0.67)
RJ45 Outlet
per IEC 60603-7
24.6
(0.97)
Thread
1-1/16 x 18 UNF
Female to Female Coupler
44.4 (1.75)
30
(1.18)
35.8
(1.41)
3.1
(0.12)
11.1
(0.44)
Max.
Panel
Thickness
27.7
(1.09)
Thread
1-1/16 x 18 UNF
Product Selection
Field Attachables Thermoplastic Overmolded Patchcord Thermoplastic
Description Cat. No.
Variant 1 housingmale 1585BP-M8CC
Variant 1 receptaclefemale 1585BP-F8CC
Female RJ45 to female RJ45 coupler 1585BP-F8BF
Male protective cap 1585BP-MCAP
Female protective cap 1585BP-FCAP
Descrip-
tion Cable Style
Operating
Temperature [C (F)] Cat. No.1
Variant 1
male to
variant 1
male
Unshielded twisted
pair, TPE high-flex, 8
conductor
-25+75
(-13+167 )
1585BT-M8TBBM-2
Foil and braided
shield, PUR,
8 conductor, high-
flex, halogen-free
-40+75
(-40+167 )
1585BT-M8UBBM-2
1 Replace -2 (2 m) with 5 (5 m) or 10 (10 m) for additional standard cable
lengths.
Home
Ethernet Media
Field Attachables
7-18
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
RJ45 Connectors
RJ45 Insulation Displacement Connector (IDC)
RJ45 Crimp
Features
IDC Connector
Up to eight conductors
2622 AWG conductors
360 shielding
No tools or conductor stripping required
Cat. 6
Crimp Connector
Up to eight conductors
2624 AWG
Standard crimp connector with rugged
boot
Cat. 5e
Specifications
Certifications UL Listed
Connector Type RJ45 male
Enclosure Type Rating IP20
Operating Temperature [C (F)] -20+60 (-4+140 )
Approximate Dimensions
12.9
(0.50)
11.6
(0.46)
14.6
(0.57)
6.6
(0.26)
51.3 (2.02)
9.4
(0.37)
RJ45 Insulation Displacement Connector (IDC)
Dimensions are in millimeters (inches). Illustrations are not drawn to scale.
RJ45 Crimp Connector
11.68
(0.46)
8.18
(0.32)
4.38 (0.17)
6.10 (0.24)
7.47
(0.29)
6.60
(0.26)
22.55 (0.89)
12.32
(0.48)
7.92
(0.31)
8.6
(0.34)
35.7
(1.4)
13.5
(0.53)
9.71
(0.38)
6.5 (0.26)
8.6
(0.64)
Dimensions are in millimeters (inches). Illustrations are not drawn to scale.
Home
Ethernet Media
Field Attachables
7-19
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
RJ45 Connectors
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
Pinout
Face View RJ45 Pinout
8-Pin
1 2 3 4 5 6 7 8
8-Pin 4-Pin
1 White/Orange
2 Orange
3 White/Green
4 Blue
5 White/Blue
6 Green
7 White/Brown
8 Brown
TxData +
TxData -
Recv Data +
Unused
Unused
Recv Data -
Unused
Unused
1 White/Orange
2 Orange
3 White/Green
4 NA
5 NA
6 Green
7 NA
8 NA
TxData +
TxData -
Recv Data +
Unused
Unused
Recv Data -
Unused
Unused
Product Selection
Description Electrical Connection Housing Material Insulation Material Contact Material Channel Bandwidth Cat. No.
RJ45 insulation
displacement
connector (IDC)
Diecast Zinc
Plastic
Gold-plated copper
alloy
Cat. 6 1 1585J-M8CC-H
RJ45 crimp connector
with boot
150V, 1.5 A Clear Polycarbonate Cat. 5e 1585J-M8CC-C
1 Qty. = 1 piece
Qty. = 50 pieces
Accessories
Description Cat. No.
Crimper, cable stripper/cutter,
conductor separator
1585A-JCRIMP
Home
Ethernet Media
Field Attachables
7-20
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
M12 Insulation Displacement Connectors
Features
Field installable with no hand tools
needed
Straight male or female shielded versions
Allows easy modification of existing cable
installations
Insulation displacement technology for
secure and reliable installation
Metal body unit excellent in shielding
applications
Specifications
Approximate Dimensions
Mechanical
Coupling Nut Material Zinc die-cast
Connector Shell Material Zinc die-cast or polyamide
Contact Material Gold-plated brass
IDC Installations 10 times, max.
Conductor OD [mm (in.)] Unshielded: 2622 AWG: 1.01.6 (0.040.063);
Shielded: 2422 AWG: 1.21.6 (0.040.063)
Electrical
Assembly Rating 32V, 4 A
Environmental
Enclosure Type Rating IP67
Operating Temperature [C (F)] -25+85 (-13+185 )
Installation Temperature [C (F)] -5+50 (23185 )
19.5
(0.76)
Dia.
M12 x 1
SW17
Across flats
47.8 (1.88)
SW13
Across flats
M12 x 1
SW17
Across flats
51.7 (2.03)
SW13
Across flats
19.5
(0.76)
Dia.
Male Female
Complete length when assembled approx. 43.45 (1.71)
Coupling
Nut
Connector
Body
O-Ring
15.3 (0.60)
Dia.
Wire
Gauge
Cable
Stop
Compression
Ring
Connector
Shell
M12 x 1
Figure A
Figure B
15 (0.60)
20 (0.75)
Dimensions are in millimeters (inches). Illustrations are not drawn to scale.
Field Attachable
Home
Ethernet Media
Field Attachables
7-21
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
M12 Insulation Displacement Connectors
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
Pinout
Color
Code
Face View M12 Pinout
4-Pin
3
2 1
4
3
2 1
4
A 1 White-Orange
2 White-Green
3 Orange
4 Green
Product Selection
No. of Pins
Connector
Material
Cable Diameter
[mm (in.)] Wire Size, AWG Assembly Rating Dimensions
Cat. No.
Straight Female Straight Male
4
Polyamide small
body unshielded
4.05.1
(0.160.20)
2622 AWG
32V, 4 A
Figure A 1585D-M4DC-H
Zinc die-cast large
body shielded
5.57.2
(0.220.28)
2422 AWG Figure B 1585D-F4DC-SH 1585D-M4DC-SH
Home
Ethernet Media
Field Attachables
7-22
Visit our website: www.ab.com/catalogs
Publication M117-CA001A-EN-P
E
t
h
e
r
n
e
t

M
e
d
i
a
Q
u
i
c
k

S
e
l
e
c
t
i
o
n
I
n
t
r
o
d
u
c
t
i
o
n
C
o
n
n
e
c
t
i
o
n
S
y
s
t
e
m
s
P
a
n
n
e
l
C
o
n
n
e
c
t
S
a
f
e
t
y
C
o
n
n
e
c
t
i
o
n
D
e
v
i
c
e
N
e
t
M
e
d
i
a
M12 to RJ45 Bulkhead Connector
Features
Specifications
Certifications UL Recognized for Canada and USA
Mechanical
Receptacle Shell Material Nickel-plated brass
Contact Material Brass with nickel plating
Wire Insulation Oil-resistant PVC, 22 AWG stranded copper, 300V, UL Recognized
Electrical
Assembly Rating 32V, 4 A
Environmental
Enclosure Type Rating IP67, 1200 psi (8270 kPa) washdown
Operating Temperature [C (F)] -20+85 (-4+185 )
Approximate Dimensions
SW 20
Across
Flats
46.2 (1.82)
28.9 (1.14)
15
(0.59)
M12 x 1
O Ring
Nut
M16 x
1.5
16.5
(0.65)
Dia. 15.4
(0.61)
Panel Cut Out
22.1
(0.87)
21.6 (0.85)
Dimensions are in millimeters (inches). Illustrations are not drawn to scale.
Product Selection
M12 to RJ45 bulkhead
Fluoroelastomer o-ring
Convenient transition from IP67 ethernet
to IP20
Cat 5e
Built-in differential 100 ohm teminators
used for unused pairs
Description Connector Material Panel Mount Assembly Rating Cat. No.
Female M12 receptacle to RJ45
female adaptor right angle
Polyamide and brass with
nickel plating
PG 9 threads 22 AWG, 32V, 4 A 1585A-DD4JD
Field Attachable
Home
Industrial Ethernet Cable Solutions
Belden offers a wide
range of high quality,
high reliability DataTuff


Industrial Ethernet cables.
Be Certain with Belden
Proven to be the Best
Choice for Industrial Ethernet
Network Applications
BIV-215410_Ind. Ethernet Distrib. Broch_FNLr1.indd 1 1/16/12 3:38 PM
Home
Nine Tests Prove Belden is the Best Choice
for Industrial Ethernet Network Application!
Belden has done extensive testing to compare both the physical and
electrical performance of commercial off-the-shelf (COTS) cables
versus industrial cables. The results of each test clearly indicate
why a commercial-grade cable is never suitable for the wide variety
of extreme conditions
that can be at play in an
industrial environment.
To conduct these tests,
Belden used their state-
of-the-art test equipment and propri-
etary test software. Its important to
note that all the cables in this study
initially tested as fully compliant to
the TIA/EIA Category 5e standards i.e., they were
validated to be good when the test began.
For more on the specic results of these tests, please
request a copy of our Industrial Ethernet User Guide
or download a copy at www.belden.com
UV EXPOSURE
HIGH
TEMPERATURE
COLD IMPACT
WATER
IMMERSION
CUT-THROUGH COLD BEND
CRUSHING
ABRASION
OIL
RESISTANCE
Be Certain With Belden.
BIV-215410_Ind. Ethernet Distrib. Broch_FNLr1.indd 2 1/16/12 3:38 PM
Home
TK
3
Belden DataTuff Industrial Ethernet Cables
Offer Peak Network Efficiency and Reliability
Inner Jacket for
additional protection
Foil and Braid for
EMI/RFI protection
Bonded Pair for
Installable Performance
Industrial Rugged Jacket
Industrial
Rugged Jacket
Foil Shield for
Noise Protection
Bonded Pair
for Installable
Performance
Bonded Pair for
Installable Performance
Industrial
Rugged Jacket
Industrial
Rugged Jacket
Stranded Conductors
for Improved Flexibility
Bonded Pair for
Installable Performance
Aluminum Armor
for Maximum
Protection
Inner Jacket
for additional
protection
DataTuff Cable Selling Points:
Breadth of line: Category 5e, Category 6
and Enhanced Category 6 cables
Most cables utilize Bonded-Pair technology
Unshielded or shielded cables
Solid or stranded conductors
Plenum or non-plenum
Polyolefin or FEP insulation
PVC, Polyethylene, FEP, and TPE jackets
Heavy, Upjacketed, and Aluminum Armored
Halogen-free and Low Smoke Zero Halogen
constructions
Versions suitable for burial or outdoor use,
gasoline resistance, high and low temperatures
Field-Proven Performance in Many
of These Conditions:
Oil, sunlight and gasoline
Temperature variations
Abrasion and crushing
Flexing
Presence of EMI/RFI (electromagnetic
interference or radio frequency interference)
Weldsplatter resistance
Approvals
All RoHS approved
Many are EtherNet/IP compliant
Some MSHA approved for mining environments
Beldens Patented Bonded-Pair Technology
Most DataTuff cables feature Beldens Bonded-
Pair technology, a patented cable construction
which afxes the conductor insulation of the
cable pairs along their longitudinal axes to
ensure that no performance-robbing gaps can
develop between the conductor pairs.
No gaps between the conductor pairs means
that the conductor-to-conductor spacing, or
centricity, is always uniform
With a uniform centricity, the cable offers
excellent and consistently reliable electrical
performance
Installable Performance is achieved - the
affixing of the insulation of the cable pairs and
the uniform centricity translate to superior
electrical performance, even after the cable
has been subjected to the bending, pulling and
twists inherent in the installation process
Tests Prove the After-installation
Effectiveness of Belden Bonded-Pair Cables
In tests performed by Belden that simulate
the effects of the installation process, both
an industry-leading 350 MHz Cat 5e cable (a
nonbonded-pair cable) and a Belden 350 MHz
Cat 5e Bonded-Pair cable were tested right off
the reel and then for the sake of comparison,
they were subjected to an Installation Stress
Test. Results showed that the nonbonded-pair
cable had an RL degradation greater than 12
dB over 15 times worse than its before-
installation value. The Bonded-Pair cables
showed little change in RL performance.
BIV-215410_Ind. Ethernet Distrib. Broch_FNLr1.indd 3 1/16/12 3:38 PM
Home
4
Category 5e Cable
7932A 2 l l l 20 l l l

7933A 2 l l l 20 l l l

7923A 4 l l l 40 l l l l l

7918A 4 l l 35 l l l l l
7924A 4 l l l 40 l l l l
7930A 4 l l 25 l l l l
7922A 4 l l l 40 l l l l
PLTC
7934A 4 l l l 40 l l l l

7937A 4 l l l 40 l l l l
7939A 4 l l l 40 l l l l
7928A 4 l l l 40 l l l l l

11700A 4 l l l 40 l l l l l

11700A2 4 l l l 40 l l l
Oil Res I&II
121700A 4 l l l 40 l l l
121700R 4 l l l 40 l l l
7929A 4 l l l 40 l l l l l
7919A 4 l l 25 l l l l l
7921A 4 l l l 75 l l l l

7957A 4 l l 75 l l l l

7935A 4 l l l 40 l l l

7936A 4 l l l 40 l l l
7958A 4 l l l 35 l l l l l

7938A 4 l l l 50 l l l l
High Flex

Category 6 Cable
7927A 4 l l l 45 l l l
7931A 4 l l l 40 l l l l l
7940A 4 l l l 40 l l l l
11872A 4 l l l 45 l
7953A 4 l l 40 l l l l
121872A 4 l l l 200 l
5 Shielded products are recommended for high-noise environments.
55 Stranded products are recommended where more exibility is needed.
Products with Bonded-Pair technology provide Installable Performance advantages refer to Beldens Bonded-Pair Cable Bulletin #BP02
Industrial Ethernet Cable Selection Guide
Part
No.
No. of
Pairs
Shielding Conductor Installation Environmental Issues Industrial Grade Jacket
Unshielded Shielded
5
Solid Stranded
55
Installation
Stress
Resistance

Pull
Tension
Oil
Resistance
UV
Sunlight
Resistance
Weld -
Splatter
Resistance
CMX/
Outdoor
Under-
ground
(burial)
Gasoline
Resistance
LSZH MSHA
Hi/Lo
Temp
600V
UL
AWM
Rated
Heavy Upjacket Armored
BIV-215410_Ind. Ethernet Distrib. Broch_FNLr1.indd 4 1/16/12 3:38 PM
Home
5
TK
Category 5e Cables, 2-Pair*, Solid Unshielded
Category 5e Cables, 2-Pair
Category 5e Cables, 2-Pair*, Solid with Foil Shield
Part
No.
AWG Conductors
No. of
Pairs

Compliant
Standard Lengths Standard Unit Wt. Nominal OD Jacket Thickness
Jacket Colors/Material
Ft. m Lbs. kg Inch mm Inch mm
Part
No.
AWG Conductors
No. of
Pairs

Compliant
Standard Lengths Standard Unit Wt. Nominal OD Jacket Thickness
Jacket Colors/Material
Ft. m Lbs. kg Inch mm Inch mm
Non-plenum
Bonded-Pair construction
Operating temperature: -40C to +75C
Installation temperature: -25C to +75C
M-12 or RJ-45 Compliant
Jacket sequentially marked at 2 ft. intervals
Cable passes -40C Cold Bend per UL1581
U.S. Patents 5,606,151 and 5,734,126
Third party verified to TIA/EIA-568-B.2, Category 5e
RoHS Compliant
Non-plenum; shielded
Bonded-Pair construction
Operating temperature: -40C to +75C
Installation temperature: -25C to +75C
Shield is bonded to jacket inner wall for electrical stability
M-12 or RJ-45 Compliant++
Jacket sequentially marked at 2 ft. intervals
Cable passes -40C Cold Bend per UL1581
U.S. Patents 5,606,151 and 5,734,126
Third party verified to TIA/EIA-568-B.2, Category 5e
RoHS Compliant
Industrial Grade Sunlight- & Oil-
resistant PVC Jacket
Polyolefin Insulation
Industrial Grade Sunlight- & Oil-
resistant PVC Outer Jacket
Polyolefin Insulation
Shield Bonded to Jacket Inner Wall for
Electrical Stability
7933A 24 Solid BC 2 l 1000 304.8 32.0 14.5 0.23 5.77 0.030 0.762 Black, Teal PVC
2000 609.6 64.8 29.4 Black PVC
7932A 24 Solid BC 2 l 1000 304.8 19.0 8.6 0.21 5.26 0.030 0.762 Black, Red, Teal PVC
2000 609.6 38.0 17.3 Black PVC
* 2-Pair Color Codes: Pair No. 1 = White/Orange Stripe & Orange; Pair No. 2 = White/Green Stripe & Green
BIV-215410_Ind. Ethernet Distrib. Broch_FNLr1.indd 5 1/16/12 3:38 PM
Home
6
Part
No.
AWG Conductors
No. of
Pairs

Compliant
Standard Lengths Standard Unit Wt. Nominal OD Jacket Thickness
Jacket Colors/Material
Ft. m Lbs. kg Inch mm Inch mm
Plenum 7928A (NEC: Limited Combustible FHC 25/50 CMP; CEC: CMP FT6)
Non-plenum (Plenum: 7928A)
Bonded-Pair construction (except 7918A)
Operating temperatures available at www.belden.com
Installation temperatures available at www.belden.com
RJ-45 Compliant
7923A is M-12 Compliant
Jacket sequentially marked at 2 ft. intervals (Except 7934A3 ft. intervals)
Cable passes -40C Cold Bend per UL1581 (7922A: -25C/7928A: -70)
U.S. Patents 5,606,151 and 5,734,126 (except 7918A)
Third party verified to TIA/EIA-568-B.2, Category 5e
RoHS Compliant
Category 5e Cables, 4-Pair
Category 5e Cables, 4-Pair*, Solid Unshielded
Industrial Grade Sunlight- & Oil-
resistant PVC Jacket (excluding
7935ASunlight Only)
Polyolefin Insulation
(7928AFEP Insulation)
* 4-Pair Color Codes: Pair No. 1 = White/Blue Stripe & Blue; Pair No. 2 = White/Orange Stripe & Orange; Pair No. 3 = White/Green Stripe & Green; Pair No. 4 = White/Brown Stripe & Brown
7923A 24 Solid BC 4 l 1000 304.8 28.0 12.7 0.23 5.84 0.030 0.762 Black, Red, Teal PVC
(MSHA Approved) 2000 609.6 54.0 24.5 Black PVC
7918A 24 Solid BC 4 1000 304.8 28.0 12.7 0.23 5.84 0.030 0.762 Black, Blue PVC
(MSHA Approved) 2000 609.6 52.0 23.6 Black PVC
7922A 22 Solid BC 4 1000 304.8 46.3 21.0 0.30 7.65 0.030 0.762 Black PVC
2000 609.6 92.5 42.0 Black PVC
7934A 24 Solid BC 4 l 1000 304.8 25.0 11.4 0.23 5.84 0.030 0.762 Black Polyethylene
(PLTC-Rated) (Halogen FreeWaterblocked Burial)
7928A 24 Solid BC 4 l 1000 304.8 24.0 10.9 0.19 4.75 0.030 0.762 Black FEP
(Plenum RatedHigh & Low Temp)
7935A 24 Solid BC 4 l 1000 304.8 24.0 10.9 0.23 5.84 0.030 0.762 Black LSZH
(Low Smoke Zero Halogen) 2000 609.6 44.0 20.0 Black LSZH
Category 5e Cables, 4-Pair*, Stranded Unshielded
7924A 24 Stranded TC 4 1000 304.8 30.0 13.6 0.24 6.15 0.030 0.762 Black, Red, Teal PVC

(7 x 32)

2000 609.6 58.0 26.3 Black PVC
7930A 24 Stranded BC 4 1000 304.8 29.0 13.2 0.24 6.09 0.030 0.762 Black PVC

(7 x 32)

2000 609.6 56.0 25.4 Black PVC
Non-plenum; stranded/flexible
Bonded-Pair construction (7924A only)
Operating temperature: -40C to +75C (7930A: -25C to +75C)
Installation temperature: -25C to +75C (7930A: -10C to +75C)
RJ-45 Compliant
Jacket sequentially marked at 2 ft. intervals
Cable passes -40C Cold Bend per UL1581 (7930A: -25C Cold Bend per UL1581)
U.S. Patents 5,606,151, 5,734,126 and 5,763,823 (7924A only)
Third party verified to TIA/EIA-568-B.2, Category 5e
RoHS Compliant
Industrial Grade Sunlight- & Oil-
resistant PVC Jacket
Polyolefin Insulation
Stranded TC Conductor for Flexibility
Part
No.
AWG Conductors
No. of
Pairs

Compliant
Standard Lengths Standard Unit Wt. Nominal OD Jacket Thickness
Jacket Colors/Material
Ft. m Lbs. kg Inch mm Inch mm
Category 5e Cables, 4-Pair*, Solid Unshielded with Double Jacket
Non-plenum; upjacketed
Bonded-Pair construction
Operating temperature: -40C to +75C (11700A2: -10C to +75C)
Installation temperature: -25C to +75C (11700A2: +5C to +75C)
RJ-45 Compliant
Jacket sequentially marked at 2 ft. intervals
Cable passes -40C Cold Bend per UL1581 (11700A2: -10C Cold Bend per UL1581)
U.S. Patents 5,606,151 and 5,734,126
Third party verified to TIA/EIA-568-B.2, Category 5e
RoHS Compliant
PVC Inner Jacket
Polyolefin Insulation
Industrial Grade Sunlight- & Oil-
resistant PVC Outer Jacket
Part
No.
AWG Conductors
No. of
Pairs

Compliant
Standard Lengths Standard Unit Wt. Nominal OD Jacket Thickness
Jacket Colors/Material
Ft. m Lbs. kg Inch mm Inch mm
11700A 24 Solid BC 4 l 1000 304.8 39.0 17.7 0.29 7.24 0.035 0.889 Black, Gray, Red, Teal, Blue PVC
(MSHA approved)
3000 914.4 117.0 53.2 Black PVC
11700A2 24 Solid BC 4 1000 304.8 42.0 19.1 0.29 7.24 0.035 0.889 Black, Blue PVC
(Oil Res I & II)
2000 609.6 86.0 39.1 Black PVC
BIV-215410_Ind. Ethernet Distrib. Broch_FNLr1.indd 6 1/16/12 3:38 PM
Home
7
TK
* 4-Pair Color Codes: Pair No. 1 = White/Blue Stripe & Blue; Pair No. 2 = White/Orange Stripe & Orange; Pair No. 3 = White/Green Stripe & Green; Pair No. 4 = White/Brown Stripe & Brown
Non-plenum
Bonded-Pair construction
Operating temperature: -40C to +75C
Installation temperature: -25C to +75C
Special RJ-45 plugs required
Jacket sequentially marked at 2 ft. intervals
Cable passes -40C Cold Bend per UL1581
U.S. Patents 5,606,151 and 5,734,126
Third party verified to TIA/EIA-568-B.2, Category 5e
RoHS Compliant
Category 5e Cables, 4-Pair*, Solid with Foil and Braid Shield
Industrial Grade Sunlight- & Oil-
resistant PVC Outer Jacket
Overall Beldfoil Shield + 24 AWG Solid
Spiral Drain Wire + 70% TC Braid
Polyolefin Insulation
Part
No.
AWG Conductors
No. of
Pairs

Compliant
Standard Lengths Standard Unit Wt. Nominal OD Jacket Thickness
Jacket Colors/Material
Ft. m Lbs. kg Inch mm Inch mm
7921A 24 Solid BC 4 l 1000 304.8 55.0 24.9 0.33 8.38 0.030 .762 Black, Red, Teal, Blue PVC
2000 609.6 106.0 48.1 Black PVC
7957A 24 Solid BC 4 l 1000 304.8 55.0 24.9 0.33 8.38 0.030 .762 Black, Teal, Blue PVC
(600V UL AWM)
2000 609.6 106.0 48.1 Black PVC
Category 5e Cables, 4-Pair*, Solid with Foil Shield and Double Jacket
Part
No.
AWG Conductors
No. of
Pairs

Compliant
Standard Lengths Standard Unit Wt. Nominal OD Jacket Thickness
Jacket Colors/Material
Ft. m Lbs. kg Inch mm Inch mm
Waterblocked, shielded, halogen free
Bonded-Pair construction
Waterblocked per Telcordia, IEC and ICEA
Operating temperature: -40C to +75C
Installation temperature: -25C to +75C
RJ-45 Compliant
Jacket sequentially marked at 2 ft. intervals
Cable passes -40C Cold Bend per UL1581
U.S. Patents 5,606,151 and 5,734,126
RoHS Compliant
Polyolefin Insulation
Industrial Grade Sunlight- & Oil-
resistant PVC Outer Jacket
PE Inner Jacket
Overall Beldfoil Shield + 24 AWG
Stranded TC Drain Wire
7937A 24 Solid BC 4 1000 304.8 38.0 17.2 0.28 7.01 0.030 .762 Black PE
Non-plenum
Bonded-Pair construction (except 7919A)
Operating temperature: -40C to +75C (7936A: -10C to +75C)
Installation temperature: -25C to +75C (7936A: +5C to +75C)
Shield is bonded to jacket inner wall for electrical stability
RJ-45 Compliant
Jacket sequentially marked at 2 ft. intervals
Cable passes -40C Cold Bend per UL1581 (7936A is -10C Cold Bend per UL1581)
U.S. Patents 5,606,151 and 5,734,126 (except 7919A)
Third party verified to TIA/EIA-568-B.2, Category 5e
RoHS Compliant
Category 5e Cables, 4-Pair*, Solid with Foil Shield
Industrial Grade Sunlight- & Oil-resistant
PVC Outer Jacket (7936ASunlight-
resistant only)
Overall Beldfoil Shield + 24 AWG
stranded TC Drain Wire
Polyolefin Insulation
Part
No.
AWG Conductors
No. of
Pairs

Compliant
Standard Lengths Standard Unit Wt. Nominal OD Jacket Thickness
Jacket Colors/Material
Ft. m Lbs. kg Inch mm Inch mm
7929A 24 Solid BC 4 1000 304.8 37.0 16.8 0.27 6.73 0.030 0.762 Black, Blue PVC
(MSHA Approved)
2000 609.6 72.0 32.7 Black PVC
7919A 24 Solid BC 4 1000 304.8 35.0 15.9 0.27 6.73 0.030 0.762 Black, Blue PVC
(MSHA Approved)
2000 609.6 68.0 30.9 Black PVC
7936A 24 Solid BC 4 1000 304.8 35.0 15.9 0.27 6.73 0.030 0.762 Black PVC
(Low Smoke Zero Halogen)
2000 609.6 76.0 34.5 Black PVC
7958A (600V) 24 Solid BC 4 l 1000 304.8 37.0 16.8 0.27 6.73 0.030 0.762 Black, Blue, Teal PVC
(600V UL AWM)
2000 609.6 72.0 32.7 Black PVC
BIV-215410_Ind. Ethernet Distrib. Broch_FNLr1.indd 7 1/16/12 3:38 PM
Home
8
7938A 24 Stranded Cu Alloy 4 500 152.4 28.0 12.7 0.34 8.60 0.030 .762 Matte Black TPE
(Continuous Flex Conductor (7x32)
Rated-10 million cycles)
Final one-piece put up length may vary -0 to +10% from length shown
Category 5e Cables, 4-Pair*, Stranded with Foil Shield
Part
No.
AWG Conductors
No. of
Pairs

Compliant
Standard Lengths Standard Unit Wt. Nominal OD Jacket Thickness
Jacket Colors/Material
Ft. m Lbs. kg Inch mm Inch mm
7939A 24 Stranded BC 4 1000 304.8 40.0 18.2 0.32 8.00 0.030 .762 Black, Teal PVC

(7x32)
2000 609.6 79.0 35.8 Black PVC
Non-plenum; shielded, stranded
Operating temperature: -40C to +75C
Installation temperature: -25C to +75C
Special RJ-45 plugs required
Jacket sequentially marked at 2 ft. intervals
Cable passes -40C Cold Bend per UL1581
RoHS Compliant
Industrial Grade Sunlight- & Oil-
resistant PVC Outer Jacket
Stranded Conductor for Flexibility
Overall Beldfoil Shield + 24 AWG
Stranded TC Drain Wire
Polyolefin Insulation
Part
No.
AWG Conductors
No. of
Pairs

Compliant
Standard Lengths Standard Unit Wt. Nominal OD Jacket Thickness
Jacket Colors/Material
Ft. m Lbs. kg Inch mm Inch mm
Part
No.
AWG Conductors
No. of
Pairs

Compliant
Standard Lengths Standard Unit Wt. Nominal OD Jacket Thickness
Jacket Colors/Material
Ft. m Lbs. kg Inch mm Inch mm
Category 5e Cables, 4-Pair*, Stranded with Foil and Braid Shield
Category 5e Cables, 4-Pair*, Solid with Interlocked Aluminum Armor
Non-plenum; upjacketed, shielded, stranded
Continuous flex rated: 10 million cycles
Weldsplatter resistant jacket
Operating temperature: -40C to +80C
Installation temperature: -25C to +80C
Special RJ-45 plugs required
Jacket sequentially marked at 2 ft. intervals
Cable passes -40C Cold Bend per UL1581
RoHS Compliant
CM rated; Aluminum interlocked armor
Operating temperature: -40C to +75C
Installation temperature: -25C to +75C
RJ-45 compatible
Jacket sequentially marked at 1 meter intervals
Cable passes -40C Cold Bend per UL1581 (121700A Only)
U.S. Patents 5,606,151 and 5,734,126
Third party verified to TIA/EIA-568-B.2, Category 5e
RoHS Compliant
TPE Inner Jacket
Polyester Wrap
Industrial Grade Sunlight-, Oil-resistant,
Weldsplatter-resistant PVC Outer
Jacket
Industrial Grade Sunlight- & Oil-
resistant PVC Outer Jacket
Polyolefin Insulation
Polyolefin Insulation
Overall Beldfoil Shield + 24 AWG
Stranded TC Drain Wire + 85% TC Braid
AL Interlocked Armor
121700A 24 Solid BC 4 1000 304.8 159.0 72.0 0.53 13.46 0.045 1.14 Black, Gray PVC
3000 914.4 459.0 210.6 Black PVC
121700R 24 Solid BC 4 1000 304.8 159.0 72.0 0.53 13.46 0.045 1.14 Black, Blue PVC
3000 914.4 459.0 210.6 Black, Blue PVC
5000 1524.0 690.0 313.0 Black, Blue PVC
* 4-Pair Color Codes: Pair No. 1 = White/Blue Stripe & Blue; Pair No. 2 = White/Orange Stripe & Orange; Pair No. 3 = White/Green Stripe & Green; Pair No. 4 = White/Brown Stripe & Brown
BIV-215410_Ind. Ethernet Distrib. Broch_FNLr1.indd 8 1/16/12 3:38 PM
Home
9
TK
* 4-Pair Color Codes: Pair No. 1 = White/Blue Stripe & Blue; Pair No. 2 = White/Orange Stripe & Orange; Pair No. 3 = White/Green Stripe & Green; Pair No. 4 = White/Brown Stripe & Brown
Category 6 Cables, 4-Pair*, Solid Unshielded with E-Spline Center Member
Category 6 Cables, 4-Pair*, Solid Unshielded with FEP Insulation
Part
No.
AWG Conductors
No. of
Pairs

Compliant
Standard Lengths Standard Unit Wt. Nominal OD Jacket Thickness
Jacket Colors/Material
Ft. m Lbs. kg Inch mm Inch mm
Part
No.
AWG Conductors
No. of
Pairs

Compliant
Standard Lengths Standard Unit Wt. Nominal OD Jacket Thickness
Jacket Colors/Material
Ft. m Lbs. kg Inch mm Inch mm
Non-plenum
Bonded-Pair construction
Operating temperature: -40C to +75C
Installation temperature: -25C to +75C
Special RJ-45 plugs required
Jacket sequentially marked at 2 ft. intervals
Cable passes -40C Cold Bend per UL1581
U.S. Patents 5,606,151, 5,734,126; 5,789,711 and 6,297,454-B1
Third party verified to TIA/EIA-568-B.2-1, Category 6
RoHS Compliant
Plenum (NEC: Limited Combustible FHC 25/50 CMP; CEC: CMP FT6)
Oil Res I & II; Gas Res
Bonded-Pair construction
Operating temperature: -70C to +150C
Installation temperature: -55C to +150C
RJ-45 Compliant
Jacket sequentially marked at 2 ft. intervals
Cable passes -70C Cold Bend per UL1581
U.S. Patents 5,606,151 and 5,734,126
Third party verified to TIA/EIA-568-B.2-1, Category 6
RoHS Compliant
Polyolefin Insulation
FEP Insulation
Patented E-Spline Center Member
Industrial Grade Sunlight- & Oil-
resistant PVC Jacket
Industrial Grade Sunlight- &
Oil-resistant PVC Jacket
7927A 23 Solid BC 4 1000 304.8 44.0 20.0 .251 x .339 6.38 x 8.61 0.030 0.762 Black PVC
2000 609.6 88.0 39.9 Black PVC
7931A 23 Solid BC 4 1000 304.8 35.0 15.9 0.21 5.44 0.030 0.762 Black FEP
(Plenum RatedHigh & Low Temp)
Category 6 Cables, 4-Pair*, Solid Unshielded with Internal Tape Separator
Category 6 Cables, 4-Pair
Part
No.
AWG Conductors
No. of
Pairs

Compliant
Standard Lengths Standard Unit Wt. Nominal OD Jacket Thickness
Jacket Colors/Material
Ft. m Lbs. kg Inch mm Inch mm
Non-plenum
Bonded-Pair construction
Operating temperature: -40C to +75C
Installation temperature: -25C to +75C
Special RJ-45 plugs required
Jacket sequentially marked at 2 ft. intervals
Cable passes -40C Cold Bend per UL1581
U.S. Patents 5,606,151, 5,734,126 and 5,821,467
Verified to TIA/EIA-568-B.2-1, Category 6
RoHS Compliant
Industrial Grade Sunlight- &
Oil-resistant PVC Jacket
Internal Tape Separator
Polyolefin Insulation
7940A 23 Solid BC 4 1000 304.8 32.0 14.5 0.25 6.35 0.030 0.762 Black PVC
2000 609.6 64.0 29.0 Black PVC
BIV-215410_Ind. Ethernet Distrib. Broch_FNLr1.indd 9 1/16/12 3:38 PM
Home
10
Category 6 Cables, 4-Pair*, Solid with Foil Shield and Double Jacket
Category 6 Cables, 4-Pair*, Solid Unshielded with Double Jacket
Category 6 Cables, 4-Pair*, Solid Unshielded with Double Jacket and Interlocked Aluminum Armor
Part
No.
AWG Conductors
No. of
Pairs

Compliant
Standard Lengths Standard Unit Wt. Nominal OD Jacket Thickness
Jacket Colors/Material
Ft. m Lbs. kg Inch mm Inch mm
Part
No.
AWG Conductors
No. of
Pairs

Compliant
Standard Lengths Standard Unit Wt. Nominal OD Jacket Thickness
Jacket Colors/Material
Ft. m Lbs. kg Inch mm Inch mm
Part
No.
AWG Conductors
No. of
Pairs

Compliant
Standard Lengths Standard Unit Wt. Nominal OD Jacket Thickness
Jacket Colors/Material
Ft. m Lbs. kg Inch mm Inch mm
Non-plenum; shielded
Operating temperature: -40C to +75C
Installation temperature: -25C to +75C
Special RJ-45 plugs required
Jacket sequentially marked at 2 ft. intervals
Cable passes -40C Cold Bend per UL1581
U.S. Patents 5,606,151, 5,734,126 and 5,821,467
Verified to TIA/EIA-568-B.2-1, Category 6
RoHS Compliant
Non-plenum; upjacketed
Bonded-Pair construction
Operating temperature: -25C to +75C
Installation temperature: -10C to +75C
RJ-45 Compliant
Jacket sequentially marked at 2 ft. intervals
Cable passes -25C Cold Bend per UL1581
U.S. Patents 5,606,151, 5,734,126 and 5,821,467
Verified to TIA/EIA-568-B.2-1, Category 6
RoHS Compliant
Non-plenum; interlocked aluminum armored
Bonded-Pair construction
Operating temperature: -40C to +75C
Installation temperature: -25C to +75C
RJ-45 Compliant
Jacket sequentially marked at 2 ft. intervals
Cable passes -40C Cold Bend per UL1581
U.S. Patents 5,606,151, 5,734,126 and 5,821,467
Verified to TIA/EIA-568-B.2-1, Category 6
RoHS Compliant
FRPO Inner Jacket
Internal Tape Separator
Polyolefin Insulation
Overall Beldfoil Shield + 24 AWG
Stranded TC Drain Wire
Industrial Grade Sunlight- & Oil-
resistant PVC Outer Jacket
Polyolefin Insulation
PVC Inner Jacket
Industrial Grade Heavy Outer Jacket
7953A 23 Solid BC 4 1000 304.8 32.0 14.5 0.34 8.64 0.030 0.762 Black PVC
5000 609.6 64.0 29.0 Black PVC
11872A 23 Solid BC 4 1000 304.8 66.0 30.0 .475 x .265 12.07 x 6.73 0.035 0.762 Black, Gray PVC
* Subject to length de-rating
** Pennsylvania Department of Environmental Resources and United States Mine Safety and Health Administration Certification
121872A 23 Solid BC 4 1000 304.8 222.0 100.6 0.68 17.37 0.055 1.397 Black, Gray PVC
AL Interlocked Armor
PVC Inner Jacket
Polyolefin Insulation
Polyester Wrap
Industrial Grade Sunlight-
& Oil-resistant PVC Outer Jacket
* 4-Pair Color Codes: Pair No. 1 = White/Blue Stripe & Blue; Pair No. 2 = White/Orange Stripe & Orange; Pair No. 3 = White/Green Stripe & Green; Pair No. 4 = White/Brown Stripe & Brown
BIV-215410_Ind. Ethernet Distrib. Broch_FNLr1.indd 10 1/16/12 3:38 PM
Home
11
TK
TrayOptic

Industrial, Heavy-Duty, All Dielectric Cable


Loose Tube Indoor/Outdoor Riser Rated
Applications
Industrial and other harsh environment
applications
Factory automation
Direct burial
Product Description
Laser Optimized Fiber to handle Gigabit Ethernet
light sources and expanded bandwidth
requirements. Passes IEEE 1202/583-2003
ame test. Waterblocking agent for moisture
protection. CPE outer jacket option provides
extra chemical or abrasion resistance.
Jacket Material PVC or CPE
Strength Member Aramid Yarn
Jacket Color
Single-mode Yellow
62.5/125 m Orange
50/125 m / 1 Gb Orange
50/125 m / 10 Gb Aqua

Ratings
Riser
UL Type OFNR
cUL Type OFN FT.4
Flame Resistance IEEE 1202 / 383-2003
Complies to:
TIA/EIA-568-C.3
ICEA S-104-696
Functional Requirements of:
GR-20-CORE
GR-409-CORE
Specications
Temperature Range
Storage -40 to +70C
Operating -40 to +70C
Crush Resistance 2000 N/cm
(EIA-455-41)
Impact Resistance 2000 impacts @ 1.6N-m
(EIA-455-25)
Cyclic Flexing 25 cycles, 12 lbs.,
(EIA-455-104) 20 x OD radius min.
Min. Bend Radius
Installation 20 x OD
Long Term 15 x OD
Maximum Installation Load 600 lbs. (2700 N)
Optical Specications See page 41
Fiber Bundle Detail
Binder
Optical
Fibers
Waterblocking
Agent
Inner Jacket
Dielectric Central
Strength Member
Outer Jacket
Gel-filled
Buffer Tube
Aramid Strength
Member
TrayOptic Series
Riser (NEC/CEC OFNR/OFN FT.4) PVC Jacket Indoor/Outdoor
2 2 I100255 I1A0255 I1C0255 I1E0255 I1W0255 0.43 11.00 92 136 600 2700
4 4 I100455 I1A0455 I1C0455 I1E0455 I1W0455 0.43 11.00 92 136 600 2700
6 6 I100655 I1A0655 I1C0655 I1E0655 I1W0655 0.43 11.00 92 136 600 2700
8 4 I400855 I4A0855 I4C0855 I4E0855 I4W0855 0.43 11.00 92 136 600 2700
12 6 I601255 I6A1255 I6C1255 I6E1255 I6W1255 0.43 11.00 92 136 600 2700
18 6 I601855 I6A1855 I6C1855 I6E1855 I6W1855 0.43 11.00 92 136 600 2700
24 6 I602455 I6A2455 I6C2455 I6E2455 I6W2455 0.43 11.00 92 136 600 2700
36 6 I603655 I6A3655 I6C3655 I6E3655 I6W3655 0.43 11.00 92 136 600 2700
48 12 I604855 I6A4855 I6C4855 I6E4855 I6W4855 0.54 13.72 128 186 600 2700
60 12 I606055 I6A6055 I6C6055 I6E6055 I6W6055 0.54 13.72 128 186 600 2700
72 12 I607255 I6A7255 I6C7255 I6E7255 I6W7255 0.54 13.72 128 186 600 2700
Riser (NEC/CEC OFNR/OFN FT.4) CPE Jacket Indoor/Outdoor
2 2 I100266 I1A0266 I1C0266 I1E0266 I1W0266 0.43 10.90 89 124 600 2700
4 4 I100466 I1A0466 I1C0466 I1E0466 I1W0466 0.43 10.90 89 124 600 2700
6 6 I100666 I1A0666 I1C0666 I1E0666 I1W0666 0.43 10.90 89 124 600 2700
8 4 I400866 I4A0866 I4C0866 I4E0866 I4W0866 0.43 10.90 89 124 600 2700
12 6 I601266 I6A1266 I6C1266 I6E1266 I6W1266 0.43 10.90 89 124 600 2700
18 6 I601866 I6A1866 I6C1866 I6E1866 I6W1866 0.43 10.90 89 124 600 2700
24 6 I602466 I6A2466 I6C2466 I6E2466 I6W2466 0.43 10.90 89 124 600 2700
36 6 I603666 I6A3666 I6C3666 I6E3666 I6W3666 0.43 10.90 89 124 600 2700
48 12 I604866 I6A4866 I6C4866 I6E4866 I6W4866 0.54 13.72 125 192 600 2700
60 12 I606066 I6A6066 I6C6066 I6E6066 I6W6066 0.54 13.72 125 192 600 2700
72 12 I607266 I6A7266 I6C7266 I6E7266 I6W7266 0.54 13.72 125 192 600 2700
No. of
Fibers
No. of
Fibers
Per
Bundle
Belden Part Number Outside Diameter Weight Max. Install Load
OM1
62.5 / 125 m
Std. / 1 Gb
OM2
50 / 125 m
Std. / 1 Gb
OM3
50 / 125 m
10 Gb 300 m
OM4
50 / 125 m
10 Gb 550 m
OS2
Single-mode
Enhanced
Inch mm lb/1000 ft kg/km lb N
BIV-215410_Ind. Ethernet Distrib. Broch_FNLr1.indd 11 1/16/12 3:38 PM
Home
B.34 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.
PHYSICAL INFRASTRUCTURE SYSTEMS
A.
System
Overview
B.
Copper
Systems
C.
Fiber
Optic
Systems
D.
Power
over
Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
TX6

PLUS UTP Patch Cords


For lengths 1 to 20 feet (increments of one foot) and 25, 30, 35, 40 feet change the length designation in the
part number to the desired length. For standard cable colors other than Off White, add suffix BL (Black), BU
(Blue), GR (Green), RD (Red), YL (Yellow), OR (Orange), or VL (Violet) before Y at the end of the part number.
For example, the part number for a blue 15-foot patch cord is UTPSP15BUY.
*For lengths other than 3 feet (5, 7, 10, 14 feet) change the length designation in the part number to the desired
length. For standard cable colors other than Black, replace suffix BL (Black) with BU (Blue), RD (Red), YL (Yellow),
GR (Green), or OR (Orange), each color representing a different keyed configuration.
Contact customer service for universal reference patch cords.
Patch cord color bands available on page B.96.
RJ45 plug lock-in device available on page B.94.
To ensure optimal performance, Panduit recommends use with other Panduit TX6 PLUS components.
Exceed ANSI/TIA-568-C.2 Category 6 and ISO 11801
Class E standards
Meet requirements of IEEE 802.3af and IEEE 802.3at
for PoE applications
Each patch cord is 100% performance tested to
component limits and wired T568B
Color-coded, keyed modular plugs mechanically and
visually distinguish connections to prevent unintentional
mating with unlike keyed or non-keyed jack modules
accommodating more discrete networks
Constructed of Category 6, 24 AWG UTP stranded cable
and TX6

PLUS Modular Plugs; plug contacts plated with


50 microinches of gold for superior performance
Plug meets all applicable ANSI/TIA/EIA-968-A
requirements and exceeds IEC 60603-7 specifications
Slender strain relief boot provides easy access in high
density applications
Plug uses an integral pair manager to optimize
performance and consistency by reducing untwisting of
conductors within the plug
Perform in center of TIA/EIA component range, ensuring
interoperability and excellent performance
Labels on patch cords provide identification of
performance level, length, and quality control number
Patented tangle-free latch prevents snags and provides
easy release, saving time on frequent moves, adds,
and changes
Optional patch cord color bands snap on and off individual
patch cables offering endless color-coding options
Optional RJ45 plug lock-in device blocks unauthorized
removal of cable, IP phone, other networking equipment,
or critical connection
Third party tested for Category 6 component compliance
Labels for TX6

PLUS UTP Patch Cords


For complete labeling solutions and product information, reference charts on pages O.1 O.25.
Part Number Part Description
Length
(Ft.)
Cable
Color
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
Patch Cord
UTPSP3Y Category 6, UTP patch cord with TX6

PLUS
Modular Plugs on each end.
3 Off White 1 10
Keyed Patch Cord
UTPKSP3BL* Keyed, Category 6, UTP patch cord with TX6

PLUS Keyed Modular Plug on one end and


TX6

PLUS Non-Keyed Modular Plug on the


other end.
3 Black 1 10
Suggested Label Solutions for TIA/EIA-606-A Compliance
Patch Cord
Part Number
Laser/Ink Jet Desktop
Printer Label
TDP43ME Thermal Transfer
Desktop Printer Label
PanTher

LS8E
Hand-Held Printer Label
Cougar

LS9
Hand-Held Printer Label
All Patch Cords S100X150YAJ S100X150VATY S100X150VAC T100X000CBC-BK
Home
B.46 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.
PHYSICAL INFRASTRUCTURE SYSTEMS
A.
System
Overview
B.
Copper
Systems
C.
Fiber
Optic
Systems
D.
Power
over
Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
TX5e

UTP Patch Cords


For complete labeling solutions and product information, reference charts on pages O.1 O.25.
Exceed ANSI/TIA-568-C.2 Category 5e and ISO 11801
Class D standards
Meet requirements of IEEE 802.3af and IEEE 802.3at
for PoE applications
Color-coded, keyed modular plugs mechanically and
visually distinguish connections to prevent unintentional
mating with unlike keyed or non-keyed jack modules
accommodating more discrete networks
Each patch cord is 100% performance tested to
component limits and wired to T568A
Constructed of Category 5e, 24 AWG UTP stranded cable
and Pan-Plug

Modular Plugs; plug contacts plated with


50 microinches of gold for superior performance
Plug meets all applicable ANSI/TIA/EIA-968-A
requirements and exceeds IEC 60603-7 specifications
Patented tangle-free latch prevents snags and provides
easy release, saving time on frequent moves, adds,
and changes
Labels on patch cords provide identification of
performance level, length, and quality control number
Optional patch cord color bands snap on and off individual
patch cables offering endless color-coding options
Optional RJ45 plug lock-in device blocks unauthorized
removal of cable, IP phone, other networking equipment,
or critical connection
Third party tested to Category 5e component compliance
For lengths 1 to 20 feet (increments of one foot) and 25, 30, 35, 40 feet change the length designation in the part
number to the desired length. For standard cable colors other than Off White, add suffix BL (Black), BU (Blue), GR
(Green), RD (Red), YL (Yellow), OR (Orange), or VL (Violet) before the Y in the part number. For example, the part
number for a blue 15-foot patch cord is UTPCH15BUY.
*For lengths other than 3 feet (5, 7, 10, 14 feet) change the length designation in the part number to the desired
length. For standard cable colors other than Black, replace suffix BL (Black) with BU (Blue), RD (Red), YL (Yellow),
GR (Green), or OR (Orange), each color representing a different keyed configuration.
Contact customer service for universal reference patch cords.
Patch cord color bands available on page B.91.
RJ45 plug lock-in device available on page B.94.
Labels for TX5e

UTP Patch Cords


Part Number Part Description
Length
(Ft.)
Cable
Color
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
Patch Cords
UTPCH3Y Category 5e, UTP patch cord with Pan-Plug

Modular Plugs on each end.


3 Off White 1 10
Keyed Patch Cords
UTPKCH3BL* Keyed, Category 5e, UTP patch cord with
Pan-Plug

Keyed Modular Plug on one end


and Pan-Plug

Non-Keyed Modular Plug on the


other end.
3 Black 1 10
Suggested Label Solutions for TIA/EIA-606-A Compliance
Patch Cord
Part Number
Laser/Ink Jet Desktop
Printer Label
TDP43ME Thermal Transfer
Desktop Printer Label
PanTher

LS8E
Hand-Held Printer Label
Cougar

LS9
Hand-Held Printer Label
All Patch Cords S100X150YAJ S100X150VATY S100X150VAC T100X000CBC-BK
Home
B.50 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.
PHYSICAL INFRASTRUCTURE SYSTEMS
A.
System
Overview
B.
Copper
Systems
C.
Fiber
Optic
Systems
D.
Power
over
Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
TX5e

Shielded Patch Cords


Exceed ANSI/TIA-568-C.2 Category 5e and ISO 11801
Class D standards
Meet requirements of IEEE 802.3af and IEEE 802.3at for
PoE applications
Color-coded, keyed modular plugs mechanically and
visually distinguish connections to prevent unintentional
mating with unlike keyed or non-keyed jack modules
accommodating more discrete networks
Each patch cord is 100% performance tested to
component limits and wired T568A
Constructed of Category 5e, 26 AWG, STP stranded,
LSZH/CM cable and Pan-Plug

Shielded Modular Plugs;


plug contacts plated with 50 microinches of gold for
superior performance
Plug meets all applicable ANSI/TIA/EIA-968-A
requirements and exceeds IEC 60603-7 specifications
Patented tangle-free latch prevents snags and provides
easy release, saving time on frequent moves, adds,
and changes
Labels on patch cords provide identification of
performance level, length, and quality control number
Optional patch cord color bands snap on and off individual
patch cables offering endless color-coding options
Optional RJ45 plug lock-in device blocks unauthorized
removal of cable, IP phone, other networking equipment,
or critical connection
For lengths 1 to 10 meters (increments of one meter) and 0.5, 1.5, 2.5, 15, 20, 25, 30, 35, 40 meters change the
length designation in the part number to the desired length. For boot colors other than Black, replace suffix
BL (Black) with BU (Blue), GR (Green), RD (Red), or YL (Yellow). For example, the part number for a 15 meter
patch cord with blue boots is STPCH15MBBU.
*For lengths other than 3 feet (5, 7, 10, 14 feet) change the length designation in the part number to the desired
length. For boot colors other than Black, replace suffix BL (Black) with BU (Blue), RD (Red), YL (Yellow), GR
(Green), or OR (Orange), each color representing a different keyed configuration. Contact customer service for
universal reference patch cords.
Patch cord color bands available on page B.96.
RJ45 plug lock-in device available on page B.94.
Labels for TX5e

Shielded Patch Cords


For complete labeling solutions and product information, reference charts on pages O.1 O.25.
Suggested Label Solutions for TIA/EIA-606-A Compliance
Patch Cord
Part Number
Laser/Ink Jet Desktop
Printer Label
TDP43ME Thermal Transfer
Desktop Printer Label
PanTher

LS8E
Hand-Held Printer Label
Cougar

LS9
Hand-Held Printer Label
All Patch Cords S100X150YAJ S100X150VATY S100X150VAC T100X000CBC-BK
Part Number Part Description
Length
(m)
Boot
Color
Cable
Color
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
Patch Cords
STPCH1MBBL Category 5e, shielded patch cord
with Pan-Plug

Shielded Modular
Plugs on each end.
1 Black International
Gray
1 10
Part Number Part Description
Length
(Ft.)
Boot
Color
Cable
Color
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
Keyed Patch Cords
STPKCH3BL Keyed, Category 5e, shielded
patch cord with Pan-Plug

Keyed
Shielded Modular Plug on one
end and Pan-Plug

Non-Keyed
Shielded Modular Plug on the
other end.
3 Black International
Gray
1 10
Home
Index Page
GenSPEED

Category 6A
Quick Reference Guide 11
GenSPEED

10 MTP
Category 6A Cable 12-13
GenSPEED

10,000
Category 6a
U/FTP (STP) Cable 14-15
GenSPEED

10,000
Category 6A
F/UTP (ScTP) Cable 16-17
GenSPEED

10,000
Category 6a Cable 18-19
GenSPEED

10,000
with 17 FREE
Category 6a Cable 20-21
General Cable recognizes that application and performance needs may vary,
which is why the Company is pleased to now offer four 10 Gigabit solutions:
GenSPEED

10 MTP Category 6A 10 Gig Cable; GenSPEED

10,000
Category 6a 10 Gig Cable; GenSPEED

10,000 Shielded Category 6a 10 Gig


Cable; and NextGen

OM3 Fiber Optic 10 Gig Cable.


General Cables industry-leading 10 Gig solution, GenSPEED 10 MTP
Category 6A Cable, featuring the new revolutionary Mosaic Crossblock
technology, provides an Unshielded-Twisted Pair (UTP) cable that performs
like a Shielded or Foiled-Twisted Pair (STP/FTP) cable.
GenSPEED 10 MTPs Mosaic Crossblock technology shields the cable from
noise coming from external cable sources, which is referred to as alien
crosstalk (PSANEXT and PSAACRF). The Mosaic Crossblock was carefully
designed with metallic blocks separated by an insulating layer. Since there is
no metal-to-metal contact, there is no path for current to flow longitudinally,
and thus, no need for grounding.
General Cables second offering, GenSPEED 10,000 Category 6a Cable,
is a cost-effective, standard-compliant 10 Gig UTP cabling option designed
to meet ANSI/TIA 568-C.2. Perfect for component upgrades, this cable
is fully backward-compatible to legacy infrastructures and prepares your
system for future 10 Gigabit applications. GenSPEED 10,000 solves the
One Gigabit limitation of Category 5e and Category 6 and is an ideal solution
for bandwidth-intensive applications. Ask your General Cable representative
about our 17 FREE line of riser-rated GenSPEED 10,000 cables, which may
qualify for LEED credit from the U.S. Green Building Council.
Next is General Cables GenSPEED 10,000 Category 6a Shielded 10 Gig
Cable. GenSPEED 10,000 Shielded is a U/FTP cable with individually shielded
pairs for optimized isolation between pairs and immunity from external noise
characterized by powersum alien crosstalk (PSANEXT) in cable bundles. Shields
are an extremely effective way of protecting the cable from outside noise
(alien sources) by moving the electromagnetic energy away from the pairs
and directing it through the shield and drain wire to the ground. Of course,
STP cables are only effective if they are properly grounded. GenSPEED 10,000
Shielded offers you the ultimate PSANEXT protection.
Last but not least, General Cable rounds out its 10 Gig offering with
NextGen OM3 Fiber Optic Cable, the optimum in 10 Gb/s fiber (which
can be found in our Fiber Optic Catalog). General Cable has partnered
with Corning

Optical Fiber to supply you the worlds most technologically


advanced optical fiber cables. The bandwidth is ensured by minEMBc, and
uniformity provides field performance of shorter lengths. With 100% testing
on this product, you dont have to worry about performance and reliability.
Your cabling system will be future-proofed, because all NextGen 10 Gb/s
fiber exceeds the specifications to which it is sold, typically allowing for
more system margin and extended reach.
GenSPEED

Category 6A Enhanced Cables 1


10
Datacom
Home
STANDARD ENHANCED PREMIUM
JACKET
COLOR PACKAGE
Category 6a
GenSPEED

10,000 (p. 18)


Category 6a
GenSPEED

10,000 Shielded (p. 14)


Enhanced Category 6A
GenSPEED

10 MTP

(p. 12)
CMR CMP CMR CMP CMR CMP
Blue
Pull-Pac

Spool-Pac

Spool 7133819 7131819 7133786 7131786 7133849 7131849


White
Pull-Pac

Spool-Pac

Spool 7133820 7131820 7133787 7131787 7133850 7131850


Yellow
Pull-Pac

Spool-Pac

Spool 7133822 7131822 7133788 7131788 7133852 7131852


Gray
Pull-Pac

Spool-Pac

Spool 7133821 7131821 7133789 7131789 7133851 7131851


Red
Pull-Pac

Spool-Pac

Spool 7133824 7131824 7133790 7131790 7133854 7131854


Orange
Pull-Pac

Spool-Pac

Spool 7133826 7131826 7133791 7131791 7133856 7131856


Green
Pull-Pac

Spool-Pac

Spool 7133823 7131823 7133792 7131792 7133853 7131853


Black
Pull-Pac

Spool-Pac

Spool 7133828 7131828 7133858 7131858


Pink
Pull-Pac

Spool-Pac

Spool 7133827 7131827 7133857 7131857


Purple
Pull-Pac

Spool-Pac

Spool 7133825 7131825 7133830 7131830 7133855 7131855


Note: Non-stock items may be subject to minimum order quantities.
GenSPEED

Category 6A Quick Reference Guide


11
Datacom GenSPEED

Category 6A Enhanced Cables


Home
12
Conductors
23 AWG solid bare annealed copper
Insulation
Non-Plenum: Polyolefin
Plenum: Fluoropolymer
Color Code
Pair 1: Blue-White
Pair 2: Orange-White
Pair 3: Green-White
Pair 4: Brown-White
Separator
Cross-Web
Jacket
Non-Plenum: Flame-Retardant PVC
Plenum: Low-Smoke,
Flame-Retardant PVC
GenSPEED

10 MTP

Category 6A Cable
Features And Benefits

10 MTP

unshielded-twisted pair (UTP)


design performs like a shielded or foiled-
twisted pair (STP/FTP) cable, providing
industry-leading protection from external
cable noise sources, also known as alien
crosstalk (PSANEXT and PSAACRF)

Mosaic Crossblock

is a thin tape made


up of individual metallic blocks separated
by an insulating layer. Since there is no
metal-to-metal contact, there is no path
for current to flow longitudinally, and
thus, no need for grounding

The Internal Separator optimizes internal


pair geometry to yield superior electrical
performance and maintain flexibility. This
unique cross-web stabilizes each pair to
create a smaller, round cable profile

TRU-Mark

print legend contains footage


markings from 1000 to 0

Made in U.S.A.
Applications

IEEE 802.3 10G BASE-T, 100 BASE-T

100 BASE-TX, 10 BASE-T, 1000 BASE-TX

155 Mb/s ATM

IEEE 802.3af for PoE

IEEE 802.3at for PoE Plus

ANSI X3.263: 100Mb/s


Standard Compliances

ANSI/TIA 568-C.2

NEC/CEC Type CMR (6AL1666)


for Non-Plenum

NEC/CEC Type CMP (NFPA262)


for Plenum

RoHS Compliant Directive 2002/95/EC

UL 444
CONSTRUCTION
PHYSICAL DATA
CMR (Non-Plenum) CMP (Plenum)
Nominal Cable Diameter (in) 0.305 0.300
Nominal Cable Weight (lbs/1000 ft) 40 44
Minimum Bend Radius (in) 1.25 1.25
Maximum Pulling Force (lbs) 40 40
Temperature Rating (C)
Installation: 0 to +60 0 to +60
Operation: -20 to +75 -20 to +75
Data subject to change without notice.
featuring
PART NUMBERS
Standard packaging: 1000' Spool
Spool
Jacket Color CMR (Non-Plenum) CMP (Plenum)
Blue 7133849 7131849
White 7133850 7131850
Yellow 7133852 7131852
Gray 7133851 7131851
Red 7133854 7131854
Orange 7133856 7131856
Green 7133853 7131853
Black 7133858 7131858
Pink 7133857 7131857
Purple 7133855 7131855
Note: Non-stock items may be subject to minimum order quantities.
TIA 568-C.2
Home
13
An Unshielded 6A Cable That Performs Like a Shielded Cable
ELECTRICAL CHARACTERISTICS
DC Resistance (max)
Ohms/100 m (328 ft) @ 20C
8.9
DC Resistance Unbalanced (max)
Individual Pair %
4
Delay Skew (max)
ns/100 m
35
Nom. Velocity of Propagation
% Speed of Light
70
Characteristic Impedance
Frequency (f): 1-500 MHz
Ohms
100 15
ELECTRICAL PERFORMANCE
Frequency
MHz
PSACR*
(min)
ACR*
(min)
Insertion
Loss
(min)
PSNEXT
(min)
NEXT
(min)
PSACRF
(min)
ACRF
(min)
Return Loss
(min)
TCL
(min)
PSANEXT
(min)
PSAACRF
(min)
General
Cable
Guaranteed
General
Cable
Guaranteed
TIA
568-C.2
TIA
568-C.2
TIA
568-C.2
TIA
568-C.2
TIA
568-C.2
TIA
568-C.2
TIA
568-C.2
TIA
568-C.2
General Cable
Guaranteed
General Cable
Typical
TIA
568-C.2
General Cable
Guaranteed
General Cable
Typical
1 70.2 72.2 2.1 72.3 74.3 64.8 67.8 20.0 40.0 67.0 73.0 79.0 67.0 73.0 79.0
4 59.5 61.5 3.8 63.3 65.3 52.8 55.8 23.0 40.0 67.0 73.0 79.0 66.2 72.2 78.2
10 51.4 53.4 5.9 57.3 59.3 44.8 47.8 25.0 40.0 67.0 73.0 79.0 58.2 64.2 70.2
16 46.8 48.8 7.5 54.2 56.2 40.7 43.7 25.0 38.0 67.0 73.0 79.0 54.1 60.1 66.1
20 44.4 46.4 8.4 52.8 54.8 38.8 41.8 25.0 37.0 67.0 73.0 79.0 52.2 58.2 64.2
31.25 39.4 41.4 10.5 49.9 51.9 34.9 37.9 23.6 35.1 67.0 73.0 79.0 48.3 54.3 60.3
62.5 30.4 32.4 15.0 45.4 47.4 28.9 31.9 21.5 32.0 65.6 71.6 77.6 42.3 48.3 54.3
100 23.2 25.2 19.1 42.3 44.3 24.8 27.8 20.1 30.0 62.5 68.5 74.5 38.2 44.2 50.2
150 16.0 18.0 23.7 39.7 41.7 21.3 24.3 18.9 28.2 59.9 65.9 71.9 34.7 40.7 46.7
200 10.2 12.2 27.6 37.8 39.8 18.8 21.8 18.0 27.0 58.0 64.0 70.0 32.2 38.2 44.2
250 5.2 7.2 31.1 36.3 38.3 16.8 19.8 17.3 26.0 56.5 62.5 68.5 30.2 36.2 42.2
300 0.9 2.9 34.3 35.1 37.1 15.3 18.3 16.8 25.2 55.3 61.3 67.3 28.7 34.7 40.7
400 40.1 33.3 35.3 12.8 15.8 15.9 24.0 53.5 59.5 65.5 26.2 32.2 38.2
500 45.3 31.8 33.8 10.8 13.8 15.2 23.0 52.0 58.0 64.0 24.2 30.2 36.2
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C.
*PSACR & ACR not specified in ANSI/TIA 568-C.2
TYPICAL GenSPEED

10 MTP CATEGORY 6A
CROSS-SECTION
OUTER JACKET
MOSAIC CROSSBLOCK

23 AWG CONDUCTOR
SEPARATOR
OVERALL WRAP
INSULATION
0 100 200 300 400 500 600
Frequency (MHz)
Pair 45 Pair 12 Pair 36 Pair 78 Specification
-20
-30
-40
-50
-60
-70
-80
-90
(
d
B
)
PSANEXT
0 100 200 300 400 500 600
Frequency (MHz)
Pair 45 Pair 12 Pair 36 Pair 78 Specification
-20
-30
-40
-50
-60
-70
-80
-90
(
d
B
)
PSAACRF 4 PAIR CABLES:
Bundles of 7 Test Results
Six-around-one
configuration
disturbed cable
Home
14
Conductors
23 AWG solid bare annealed copper
Insulation
Non-Plenum: Foamed HDPE
Plenum: Foamed Fluoropolymer
Color Code
Pair 1: Blue-White
Pair 2: Orange-White
Pair 3: Green-White
Pair 4: Brown-White
Shield
Each pair is individually shielded with
an aluminum foil
24 AWG drain wire
Jacket
Non-Plenum: Flame-Retardant PVC
Plenum: Low-Smoke, Flame-Retardant
PVC
GenSPEED

10,000 Category 6a U/FTP (STP) Cable


Features And Benefits

Shielded design allowing for maximum


pair separation, increasing key electrical
performance parameters

Individual pair shielding for EMI


protection

Typical positive PSACR beyond 500 MHz


for increased available bandwidth

TRU-Mark

print legend contains


footage markings from 1000' to 0'

Made in U.S.A.
Applications

IEEE 802.3an: 10G BASE-T (10 Gigabit


Ethernet)

1000 BASE-TX (Gigabit Ethernet)

2.4/1.2 Gb/s ATM

IEEE 802.3af for PoE

IEEE 802.3at for PoE Plus


Standard Compliances

ANSI/TIA 568-C.2

ISO/IEC 11801 Ed. 2.0 (Class E)

ICEA S-102-700 (Category 6)

NEC/CEC Type CMR (UL 1666) for


Non-Plenum

NEC/CEC Type CMP (NFPA 262) for


Plenum

RoHS Compliant Directive 2002/95/EC

UL 444
CONSTRUCTION
PHYSICAL DATA
CMR (Non-Plenum) CMP (Plenum)
Nominal Cable Diameter (in) 0.310 0.290
Nominal Cable Weight (lbs/1000 ft) 50 45
Minimum Bend Radius (in) 3.10 2.90
Maximum Pulling Force (lbs) 32 32
Temperature Rating (C)
Installation: 0 to +60 0 to +60
Operation: -20 to +75 -20 to +75
PART NUMBERS
Standard packaging: 1000' Spool
Spool
Jacket Color CMR (Non-Plenum) CMP (Plenum)
Blue 7133786 7131786
White 7133787 7131787
Yellow 7133788 7131788
Gray 7133789 7131789
Red 7133790 7131790
Orange 7133791 7131791
Green 7133792 7131792
Purple 7133830 7131830
Note: Non-stock items may be subject to minimum order quantities.
Data subject to change without notice.
TIA 568-C.2
Home
15
A Shielded 10 Gig Option for Peace of Mind
GenSPEED

10,000 CATEGORY 6a U/ FTP (STP)


CROSS-SECTION
ELECTRICAL CHARACTERISTICS
DC Resistance (max)
Ohms/100 m (328 ft) @ 20C
8.9
DC Resistance Unbalance (max)
Individual Pair %
4.0
Delay Skew (max)
ns/100 m
35
Nom. Velocity of Propagation
% Speed of Light
CMP: 78
CMR: 75
Characteristic Impedance
Frequency (f): 1-600 MHz
Ohms
100 15
ELECTRICAL PERFORMANCE
Frequency
MHz
PSACR*
(min)
ACR*
(min)
Insertion
Loss
(max)
PSNEXT
(min)
NEXT
(min)
PSACRF
(min)
ACRF
(min)
Return Loss
(min)
LCL/TCL
(min)
PSANEXT
(min)
PSAACRF
(min)
1 70.2 72.2 2.1 72.3 74.3 70.8 73.8 20.0 50.0 77.0 77.0
4 68.5 70.5 3.8 72.3 74.3 58.8 61.8 23.0 44.0 77.0 76.2
10 66.3 68.3 5.9 72.3 74.3 50.8 53.8 25.0 40.0 77.0 68.2
16 63.6 66.6 7.5 71.2 74.2 46.7 49.7 25.0 38.0 77.0 64.1
20 61.3 64.3 8.4 69.8 72.8 44.8 47.8 25.0 37.0 77.0 62.2
31.25 56.1 59.1 10.5 66.9 69.9 40.9 43.9 23.6 35.1 77.0 58.3
62.5 46.9 49.9 15.0 62.4 65.4 34.9 37.9 21.5 32.0 75.6 52.3
100 39.4 42.4 19.1 59.3 62.3 30.8 33.8 20.1 30.0 72.5 48.2
200 25.6 28.6 27.6 54.8 57.8 24.8 27.8 18.0 27.0 68.0 42.2
250 20.3 23.3 31.1 53.3 56.3 22.8 25.8 17.3 26.0 66.5 40.2
300 15.5 18.5 34.3 52.1 55.1 21.3 24.3 16.8 25.2 65.3 38.7
350 11.2 14.2 37.2 51.1 54.1 19.9 22.9 16.3 24.6 64.3 37.3
400 7.1 10.1 40.1 50.3 53.3 18.8 21.8 15.9 24.0 63.5 36.2
500 2.7 45.3 48.8 51.8 16.8 19.8 15.2 23.0 62.0 34.2
600 50.1 47.6 50.6 15.2 18.2 14.7 22.2 60.8 32.6
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C.
*PSACR & ACR not specified in ANSI/TIA 568-C.2
OUTER
JACKET
INDIVIDUAL
ALUMINUM
FOIL
23 AWG
CONDUCTOR
INSULATION
DRAIN WIRE
Home
16
Conductors
23 AWG solid bare annealed copper
Insulation
Non-Plenum: Polyolefin
Plenum: Fluoropolymer
Color Code
Pair 1: Blue-White
Pair 2: Orange-White
Pair 3: Green-White
Pair 4: Brown-White
Separator
Cross-Web
Core Tape
CMR: Polypropylene
CMP: Fluoropolymer
Shield
Polyester-backed aluminum foil
(aluminum side in)
Drain Wire
24 AWG stranded (7/32) solid tinned
copper
Jacket
Non-Plenum: Flame-Retardant PVC
Plenum: Low-Smoke,
Flame-Retardant PVC
GenSPEED

10,000 Category 6A F/UTP (ScTP) Cable


Features And Benefits

A shielded or foiled-twisted pair (F/UTP)


cable, requiring grounding and providing
industry-leading protection from external
cable noise sources, also known as alien
crosstalk (PSANEXT and PSAACRF)

The internal separator optimizes internal


pair geometry to yield superior electrical
performance and maintain flexibility. This
unique cross-web stabilizes each pair to
create a smaller, round cable profile

TRU-Mark

print legend contains footage


markings from 1000 to 0

Made in U.S.A.
Applications

IEEE 802.3 10G BASE-T, 100 BASE-T

100 BASE-TX, 10 BASE-T, 1000 BASE-TX

155 Mb/s ATM

IEEE 802.3af for PoE

IEEE 802.3at for PoE Plus

ANSI X3.263: 100Mb/s


Standard Compliances

ANSI/TIA 568-C.2

NEC/CEC Type CMR (UL 1666) for


Non-Plenum

NEC/CEC Type CMP (NFPA 262) for


Plenum

RoHS Compliant Directive 2002/95/EC

UL 444
CONSTRUCTION
PHYSICAL DATA
CMR (Non-Plenum) CMP (Plenum)
Nominal Cable Diameter (in) 0.310 0.295
Nominal Cable Weight (lbs/1000 ft) 42 46
Minimum Bend Radius (in) 1.25 1.25
Maximum Pulling Force (lbs) 40 40
Temperature Rating (C)
Installation: 0 to +60 0 to +60
Operation: -20 to +75 -20 to +75
Data subject to change without notice.
PART NUMBERS
Standard packaging: 1000' Spool
Spool
Jacket Color CMR (Non-Plenum) CMP (Plenum)
Blue 7133586 7131586
White 7133587 7131587
Yellow 7133588 7131588
Gray 7133589 7131589
Red 7133590 7131590
Orange 7133591 7131591
Green 7133592 7131592
Purple 7133593 7131593
Note: Non-stock items may be subject to minimum order quantities.
TIA 568-C.2
Home
17
An Enhanced Shielded Cable
ELECTRICAL CHARACTERISTICS
DC Resistance (max)
Ohms/100 m (328 ft) @ 20C
8.9
DC Resistance Unbalanced (max)
Individual Pair %
4
Delay Skew (max)
ns/100 m
35
Nom. Velocity of Propagation
% Speed of Light
70
Characteristic Impedance
Frequency (f): 1-500 MHz
Ohms
100 15
ELECTRICAL PERFORMANCE
Frequency
MHz
PSACR*
(min)
ACR*
(min)
Insertion Loss
(min)
PSNEXT
(min)
NEXT
(min)
PSACRF
(min)
ACRF
(min)
Return Loss
(min)
TCL
(min)
PSANEXT
(min)
PSAACRF
(min)
General
Cable
Guaranteed
General
Cable
Guaranteed
TIA
568-C.2
TIA
568-C.2
TIA
568-C.2
TIA
568-C.2
TIA
568-C.2
TIA
568-C.2
TIA
568-C.2
TIA
568-C.2
General
Cable
Guaranteed
General
Cable
Typical
TIA
568-C.2
General
Cable
Guaranteed
General
Cable
Typical
1 70.2 72.2 2.1 72.3 74.3 64.8 67.8 20.0 40.0 67.0 73.0 85.0 67.0 73.0 85.0
4 59.5 61.5 3.8 63.3 65.3 52.8 55.8 23.0 40.0 67.0 73.0 85.0 66.2 72.2 84.2
10 51.4 53.4 5.9 57.3 59.3 44.8 47.8 25.0 40.0 67.0 73.0 85.0 58.2 64.2 76.2
16 46.8 48.8 7.5 54.2 56.2 40.7 43.7 25.0 38.0 67.0 73.0 85.0 54.1 60.1 72.1
20 44.4 46.4 8.4 52.8 54.8 38.8 41.8 25.0 37.0 67.0 73.0 85.0 52.2 58.2 70.2
31.25 39.4 41.4 10.5 49.9 51.9 34.9 37.9 23.6 35.1 67.0 73.0 85.0 48.3 54.3 66.3
62.5 30.4 32.4 15.0 45.4 47.4 28.9 31.9 21.5 32.0 65.6 71.6 83.6 42.3 48.3 60.3
100 23.2 25.2 19.1 42.3 44.3 24.8 27.8 20.1 30.0 62.5 68.5 80.5 38.2 44.2 56.2
150 16.0 18.0 23.7 39.7 41.7 21.3 24.3 18.9 28.2 59.9 65.9 77.9 34.7 40.7 52.7
200 10.2 12.2 27.6 37.8 39.8 18.8 21.8 18.0 27.0 58.0 64.0 76.0 32.2 38.2 50.2
250 5.2 7.2 31.1 36.3 38.3 16.8 19.8 17.3 26.0 56.5 62.5 74.5 30.2 36.2 48.2
300 0.9 2.9 34.3 35.1 37.1 15.3 18.3 16.8 25.2 55.3 61.3 73.3 28.7 34.7 46.7
400 40.1 33.3 35.3 12.8 15.8 15.9 24.0 53.5 59.5 71.5 26.2 32.2 44.2
500 45.3 31.8 33.8 10.8 13.8 15.2 23.0 52.0 58.0 70.0 24.2 30.2 42.2
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C.
*PSACR & ACR not specified in ANSI/TIA 568-C.2
TYPICAL GenSPEED

10,000 CATEGORY 6A F/ UTP


(ScTP) CROSS-SECTION
OUTER JACKET
OVERALL SHIELD
23 AWG CONDUCTOR
SEPARATOR
OVERALL WRAP
INSULATION
DRAIN WIRE
Home
18
PART NUMBERS
Standard packaging: 1000' Spool
Spool
Jacket Color CMR (Non-Plenum) CMP (Plenum)
Blue 7133819 7131819
White 7133820 7131820
Yellow 7133822 7131822
Gray 7133821 7131821
Red 7133824 7131824
Orange 7133826 7131826
Green 7133823 7131823
Black 7133828 7131828
Pink 7133827 7131827
Purple 7133825 7131825
Note: Non-stock items may be subject to minimum order quantities.
GenSPEED

10,000 Category 6a Cable


CONSTRUCTION
Conductors
23 AWG solid bare annealed copper
Insulation
Non-Plenum: Polyolefin
Plenum: Fluoropolymer
Color Code
Pair 1: Blue-White
Pair 2: Orange-White
Pair 3: Green-White
Pair 4: Brown-White
Separator
T-Top cross-web
Jacket
Non-Plenum: Flame-Retardant PVC
Plenum: Low-Smoke, Flame-Retardant
PVC
PHYSICAL DATA
CMR (Non-Plenum) CMP (Plenum)
Nominal Cable Diameter (in) 0.330 0.320
Nominal Cable Weight (lbs/1000 ft) 42 45
Minimum Bend Radius (in) 1.5 1.5
Maximum Pulling Force (lbs) 40 40
Temperature Rating (C)
Installation: 0 to +60 0 to +60
Operation: -20 to +75 -20 to +75
Data subject to change without notice.
Features And Benefits

Extensive design development


conducted to find the perfect blend of
product performance and consistent
manufacturability

Innovative T-Top cross-web provides


superior internal electrical characteristics
by locking the pairs into a systematic
orientation within the cable

Superior flame and smoke characteristics


achieved through innovative design
and careful selection of materials with
certified suppliers

TRU-Mark

print legend contains footage


markings from 1000 to 0

AirEs jacket provides superior flexibility


and maximum separation of pairs from
cable to cable for consistent PSANEXT
and PSAACRF performance

Made in U.S.A.
Applications

IEEE 802.3: 10G BASE-T, 100 BASE-T

100 BASE-TX, 10 BASE-T, 1000 BASE-TX

ANSI/TIA/EIA-854: 1000 BASE-TX

155 Mb/s ATM

ANSI X3.263: 100 Mb/s

IEEE 802.3af for PoE

IEEE 802.3at for PoE Plus


Standard Compliances

ANSI/TIA 568-C.2

NEC/CEC Type CMR (UL 1666)


for Non-Plenum

NEC/CEC Type CMP (NFPA 262)


for Plenum

RoHS Compliant Directive 2002/95/EC

UL 444
TIA 568-C.2
Home
19
Signal Strength and Power
ELECTRICAL CHARACTERISTICS
DC Resistance (max)
Ohms/100 m (328 ft) @ 20C
8.9
DC Resistance Unbalance (max)
Individual Pair %
4.0
Delay Skew (max)
ns/100 m
35
Nom. Velocity of Propagation
% Speed of Light
70
Characteristic Impedance
Frequency (f): 1-500 MHz
Ohms
100 15
ELECTRICAL PERFORMANCE
Frequency
MHz
PSACR*
(min)
ACR*
(min)
Insertion
Loss
(max)
PSNEXT
(min)
NEXT
(min)
PSACRF
(min)
ACRF
(min)
Return Loss
(min)
TCL
(min)
PSANEXT
(min)
PSAACRF
(min)
1 70.2 72.2 2.1 72.3 74.3 64.8 67.8 20.0 40.0 67.0 67.0
4 59.5 61.5 3.8 63.3 65.3 52.8 55.8 23.0 40.0 67.0 66.2
8 53.5 55.5 5.3 58.8 60.8 46.7 49.7 24.5 40.0 67.0 60.1
10 51.4 53.4 5.9 57.3 59.3 44.8 47.8 25.0 40.0 67.0 58.2
16 46.7 48.7 7.5 54.2 56.2 40.7 43.7 25.0 38.0 67.0 54.1
20 44.4 46.4 8.4 52.8 54.8 38.8 41.8 25.0 37.0 67.0 52.2
25 41.9 43.9 9.4 51.3 53.3 36.8 39.8 24.3 36.0 67.0 50.2
31.25 39.4 41.4 10.5 49.9 51.9 34.9 37.9 23.6 35.1 67.0 48.3
62.5 30.4 32.4 15.0 45.4 47.4 28.9 31.9 21.5 32.0 65.6 42.3
100 23.2 25.2 19.1 42.3 44.3 24.8 27.8 20.1 30.0 62.5 38.2
200 10.2 12.2 27.6 37.8 39.8 18.8 21.8 18.0 27.0 58.0 32.2
250 5.2 7.2 31.1 36.3 38.3 16.8 19.8 17.3 26.0 56.5 30.2
300 0.8 2.8 34.3 35.1 37.1 15.3 18.3 16.8 25.2 55.3 28.7
400 40.1 33.3 35.3 12.8 15.8 15.9 24.0 53.5 26.2
500 45.3 31.8 33.8 10.8 13.8 15.2 23.0 52.0 24.2
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C.
*PSACR & ACR not specified in ANSI/TIA 568-C.2
GenSPEED

10,000 CATEGORY 6a CROSS-SECTION


AirEs
JACKET
23 AWG
CONDUCTOR
T-TOP
SEPARATOR
INSULATION
Home
20
GenSPEED

10,000 with 17 FREE

Category 6a Cable
Features And Benefits

No halogens

Less toxic

More environmentally friendly

Increased flexibility for easy installation

Performance guaranteed to 500 MHz

TRU-Mark

print legend contains footage


markings from 1000 to 0

Third-party verified for guaranteed


performance

Extensive design development


conducted to find the perfect blend of
product performance and consistent
manufacturability

Innovative T-Top cross-web provides


superior internal electrical characteristics
by locking the pairs into a systematic
orientation within the cable

Superior flame and smoke characteristics


achieved through innovative design
and careful selection of materials with
certified suppliers

AirEs jacket provides superior flexibility


and maximum separation of pairs from
cable to cable for consistent PSANEXT
and PSAACRF performance

Made in U.S.A.
Applications

IEEE 802.3: 10G BASE-T, 100 BASE-T

100 BASE-TX, 10 BASE-T, 1000 BASE-TX

ANSI/TIA-854: 1000 BASE-TX

155 Mb/s ATM

ANSI X3.263: 100 Mb/s

IEEE 802.3af for PoE

IEEE 802.3at for PoE Plus


Standard Compliances

ANSI/TIA 568-C.2

RoHS Compliant Directive 2002/95/EC

UL 444

IEC 60754-2
PART NUMBERS
Standard packaging: 1000' Spool
Spool
Jacket Color CMR (Non-Plenum)
Blue 7133819-17F
White 7133820-17F
Yellow 7133822-17F
Gray 7133821-17F
Red 7133824-17F
Orange 7133826-17F
Green 7133823-17F
Black 7133828-17F
Pink 7133827-17F
Purple 7133825-17F
Note: Non-stock items may be subject to minimum order quantities.
CONSTRUCTION
Conductors
23 AWG solid bare annealed copper
Insulation
Non-Plenum: Polyolefin
Color Code
Pair 1: Blue-White
Pair 2: Orange-White
Pair 3: Green-White
Pair 4: Brown-White
Separator
T-Top cross-web
Jacket
Non-Plenum: Zero-Halogen Polyolefin
Data subject to change without notice.
PHYSICAL DATA
CMR (Non-Plenum)
Nominal Cable Diameter (in) 0.330
Nominal Cable Weight (lbs/1000 ft) 48
Minimum Bend Radius (in) 1.5
Maximum Pulling Force (lbs) 40
Temperature Rating (C)
Installation: -10 to +60
Operation: -20 to +75
TIA 568-C.2
Home
21
Signal Strength and Power
ELECTRICAL CHARACTERISTICS
DC Resistance (max)
Ohms/100 m (328 ft) @ 20C
8.9
DC Resistance Unbalance (max)
Individual Pair %
4.0
Delay Skew (max)
ns/100 m
35
Nom. Velocity of Propagation
% Speed of Light
70
Characteristic Impedance
Frequency (f): 1-500 MHz
Ohms
100 15
ELECTRICAL PERFORMANCE
Frequency
MHz
PSACR*
(min)
ACR*
(min)
Attenuation
(max)
PSNEXT
(min)
NEXT
(min)
PSACRF
(min)
ACRF
(min)
Return Loss
(min)
TCL
(min)
PSANEXT
(min)
PSAACRF
(min)
1 70.2 72.2 2.1 72.3 74.3 64.8 67.8 20.0 40.0 67.0 67.0
4 59.5 61.5 3.8 63.3 65.3 52.8 55.8 23.0 40.0 67.0 66.2
8 53.5 55.5 5.3 58.8 60.8 46.7 49.7 24.5 40.0 67.0 60.1
10 51.4 53.4 5.9 57.3 59.3 44.8 47.8 25.0 40.0 67.0 58.2
16 46.7 48.7 7.5 54.2 56.2 40.7 43.7 25.0 38.0 67.0 54.1
20 44.4 46.4 8.4 52.8 54.8 38.8 41.8 25.0 37.0 67.0 52.2
25 41.9 43.9 9.4 51.3 53.3 36.8 39.8 24.3 36.0 67.0 50.2
31.25 39.4 41.4 10.5 49.9 51.9 34.9 37.9 23.6 35.1 67.0 48.3
62.5 30.4 32.4 15.0 45.4 47.4 28.9 31.9 21.5 32.0 65.6 42.3
100 23.2 25.2 19.1 42.3 44.3 24.8 27.8 20.1 30.0 62.5 38.2
200 10.2 12.2 27.6 37.8 39.8 18.8 21.8 18.0 27.0 58.0 32.2
250 5.2 7.2 31.1 36.3 38.3 16.8 19.8 17.3 26.0 56.5 30.2
300 0.8 2.8 34.3 35.1 37.1 15.3 18.3 16.8 25.2 55.3 28.7
400 40.1 33.3 35.3 12.8 15.8 15.9 24.0 53.5 26.2
500 45.3 31.8 33.8 10.8 13.8 15.2 23.0 52.0 24.2
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C.
*PSACR & ACR not specified in ANSI/TIA 568-C.2
GenSPEED

10,000 with 17 FREE CATEGORY 6a


CROSS-SECTION
Going Green with General Cable
General Cable has accelerated its environmental commitment, addressing its green alternative approach
by identifying greener opportunities and promoting green cabling solutions wherever feasible. This includes
promoting our existing green products, partnering with key customers in their green endeavors, identifying
and providing resources for green product gaps, becoming a member of the U.S. Green Building Council
(USGBC) and participating in collaborative ventures such as the Green Suppliers Network (GSN).
AirEs
JACKET
23 AWG
CONDUCTOR
T-TOP
SEPARATOR
INSULATION
Home
Index Page
GenSPEED

Category 6
Quick Reference Guide 23
GenSPEED

6500
Premium
Category 6 Cable 24-25
GenSPEED

6000
Enhanced
Category 6 Cable 26-27
GenSPEED

6
Category 6 Cable 28-29
GenSPEED

6
with 17 FREE
TM

Category 6 Cable 30-31
GenSPEED

6
Category 6 Interlock
Armored Cable 32-33
GenSPEED

6
Category 6
Outside Plant Cable 34-35
General Cable offers a complete line-up of Category 6 cables to
meet all your networking needs. This standard, enhanced, premium
strategy allows you to choose a cable that meets your bandwidth
needs for each application you deploy. When you need a reliable
cable with warranty assurance, choose from the series of GenSPEED


Category 6 Cables.
GenSPEED

6 is a standard-compliant Category 6 cable that features


a unique tape design engineered for consistent electrical performance.
Its TRU-Mark

print legend contains footage markings from 1000'


to 0', making usage easier to track. Also ask your General Cable
representative about our 17 FREE line of riser-rated GenSPEED 6
cables, which may qualify for LEED credit from the U.S. Green Building
Council.
General Cables GenSPEED

6000 has been enhanced to provide the


market with a cost-effective, high-bandwidth and high-performance
cabling solution for more robust and complex applications at Gigabit
speed and full duplex transmissions. The GenSPEED 6000 solution
provides a cable system infrastructure with assurance for advanced
applications demanding more bandwidth.
Featuring a revolutionary design, GenSPEED

6500 Premium provides


the industry with one of the best-performing Category 6 cables in its
class. GenSPEED 6500 Premium offers high power-sum attenuation-
to-crosstalk ratio (PSACR) and low attenuation performance for better
signal strength and power.
All GenSPEED Category 6 cables are third-party verified for guaranteed
performance and conform to ANSI/TIA/EIA 568-C.2 standards.
GenSPEED 6 and 6000 Enhanced are offered in a variety of colors and
can be shipped in General Cables easy-to-use Pull-Pac

or Spool-Pac


cartons or on a spool. GenSPEED 6500 Premium is available in a
Spool-Pac or on a spool.
GenSPEED

Category 6 Cables 2
22
Datacom
Home
STANDARD ENHANCED PREMIUM
JACKET
COLOR PACKAGE
Category 6
GenSPEED

6 (p. 28)
Category 6
GenSPEED

6000 Enhanced (p. 26)


Category 6
GenSPEED

6500 Premium (p. 24)


CMR CMP CMR CMP CMR CMP
Blue
Pull-Pac

7133800 7131800 7133900 7131900


Spool-Pac

7133840 7131840 7133940 7131940 7133930 7131930


Spool 7133860 7131860 7133960 7131960 7133970 7131970
Bulk* 7133860.2R 7131860.2.5R 7133960.3R 7131960.3R 7133970.2R 7131970.2R
White
Pull-Pac

7133801 7131801 7133901 7131901


Spool-Pac

7133841 7131841 7133941 7131941 7133931 7131931


Spool 7133861 7131861 7133961 7131961 7133971 7131971
Bulk* 7133861.2R 7131861.2.5R 7133961.3R 7131961.3R 7133971.2R 7131971.2R
Yellow
Pull-Pac

7133802 7131802 7133902 7131902


Spool-Pac

7133842 7131842 7133942 7131942 7133932 7131932


Spool 7133862 7131862 7133962 7131962 7133972 7131972
Bulk* 7133862.2R 7131862.2.5R 7133962.3R 7131962.3R 7133972.2R 7131972.2R
Gray
Pull-Pac

7133803 7131803 7133903 7131903


Spool-Pac

7133843 7131843 7133943 7131943 7133933 7131933


Spool 7133863 7131863 7133963 7131963 7133973 7131973
Bulk* 7133863.2R 7131863.2.5R 7133963.3R 7131963.3R 7133973.2R 7131973.2R
Red
Pull-Pac

7133804 7131804 7133904 7131904


Spool-Pac

7133844 7131844 7133944 7131944 7133934 7131934


Spool 7133864 7131864 7133964 7131964 7133974 7131974
Bulk* 7133864.2R 7131864.2.5R 7133964.3R 7131964.3R 7133974.2R 7131974.2R
Orange
Pull-Pac

7133805 7131805 7133905 7131905


Spool-Pac

7133845 7131845 7133945 7131945 7133935 7131935


Spool 7133865 7131865 7133965 7131965 7133975 7131975
Bulk* 7133865.2R 7131865.2.5R 7133965.3R 7131965.3R 7133975.2R 7131975.2R
Green
Pull-Pac

7133806 7131806 7133906 7131906


Spool-Pac

7133846 7131846 7133946 7131946 7133936 7131936


Spool 7133866 7131866 7133966 7131966 7133976 7131976
Bulk* 7133866.2R 7131866.2.5R 7133966.3R 7131966.3R 7133976.2R 7131976.2R
Black
Pull-Pac

7133807 7131807 7133907 7131907


Spool-Pac

7133847 7131847 7133947 7131947 7133937 7131937


Spool 7133867 7131867 7133967 7131967 7133977 7131977
Bulk* 7133867.2R 7131867.2.5R 7133967.3R 7131967.3R 7133977.2R 7131977.2R
Pink
Pull-Pac

7133808 7131808 7133908 7131908


Spool-Pac

7133848 7131848 7133948 7131948 7133938 7131938


Spool 7133868 7131868 7133968 7131968 7133978 7131978
Bulk* 7133868.2R 7131868.2.5R 7133968.3R 7131968.3R 7133978.2R 7131978.2R
Purple
Pull-Pac

7133809 7131809 7133909 7131909


Spool-Pac

7133859 7131859 7133959 7131959 7133939 7131939


Spool 7133869 7131869 7133969 7131969 7133979 7131979
Bulk* 7133869.2R 7131869.2.5R 7133969.3R 7131969.3R 7133979.2R 7131979.2R
Note: Non-stock items may be subject to minimum order quantities.
* Bulk reels are available in 2000' (2R), 2500' (2.5R), and 3000' (3R) lengths.
GenSPEED

Category 6 Quick Reference Guide


23
Datacom GenSPEED

Category 6 Enhanced Cables


Home
24
GenSPEED

6500 Premium Category 6 Cable


Features And Benefits

Designed and engineered with precision


balance to offer ultimate headroom

High-end optimized performance to


support the most bandwidth-intense
applications

New and improved separator


construction allowing for more
pair separation

Performance guaranteed to 350 MHz

TRU-Mark

print legend contains


footage markings from 1000' to 0'

Third-party verified for guaranteed


performance

Made in U.S.A.
Applications

IEEE 802.3: 1000 BASE-T (Gigabit


Ethernet), 100 BASE-TX, 10 BASE-T

ANSI/TIA/EIA 854: 1000 BASE-TX

155 Mp/s, 1.2 Gb/s ATM

ANSI X3.263: 100 Mb/s

IEEE 802.3af DTE Power (PoE)

IEEE 802.3at for PoE Plus

Digital Video

Broadband and Baseband Analog Video


Standard Compliances

ANSI/TIA 568-C.2

ANSI/TIA 862 (Building Automation)

ISO/IEC 11801 Ed. 2.0 (Class E)

ICEA S-102-700 (Category 6)

NEC/CEC Type CMR (UL 1666) for


Non-Plenum

NEC/CEC Type CMP (NFPA 262)


for Plenum

RoHS Compliant Directive 2002/95/EC

UL 444
CONSTRUCTION
Conductors
23 AWG solid bare annealed copper
Insulation
Non-Plenum: Polyolefin
Plenum: Fluoropolymer
Color Code
Pair 1: Blue-White/Blue
Pair 2: Orange-White/Orange
Pair 3: Green-White/Green
Pair 4: Brown-White/Brown
Separator
Cross-web
Rip Cord
Applied longitudinally under jacket
Jacket
Non-Plenum: Flame-Retardant PVC
Plenum: Low-Smoke,
Flame-Retardant PVC
PART NUMBERS
Standard packaging: 1000' Spool-Pac

Spool-Pac

Spool
Jacket Color CMR (Non-Plenum) CMP (Plenum) CMR (Non-Plenum) CMP (Plenum)
Blue 7133930 7131930 7133970 7131970
White 7133931 7131931 7133971 7131971
Yellow 7133932 7131932 7133972 7131972
Gray 7133933 7131933 7133973 7131973
Red 7133934 7131934 7133974 7131974
Orange 7133935 7131935 7133975 7131975
Green 7133936 7131936 7133976 7131976
Black 7133937 7131937 7133977 7131977
Pink 7133938 7131938 7133978 7131978
Purple 7133939 7131939 7133979 7131979
Note: Bulk reels are available as a special request with a maximum allowable length of 3000 feet per reel. Minimum run and
lead time may apply.
Non-stock items may be subject to minimum order quantities.
PHYSICAL DATA
CMR (Non-Plenum) CMP (Plenum)
Nominal Cable Diameter (in) 0.260 0.255
Nominal Cable Weight (lbs/1000 ft) 32 31
Minimum Bend Radius (in) 1.0 1.0
Maximum Pulling Force (lbs) 50 50
Temperature Rating (C)
Installation: 0 to +60 0 to +60
Operation: -20 to +75 -20 to +75
Data subject to change without notice.
TIA 568-C.2
Home
25
Signal Strength and Power
ELECTRICAL CHARACTERISTICS
DC Resistance (max)
Ohms/100 m (328 ft) @ 20C
8.9
DC Resistance Unbalance (max)
Individual Pair %
3.0
Delay Skew (max)
ns/100 m
45
Nom. Velocity of Propagation
% Speed of Light
CMP: 72
CMR: 70
Characteristic Impedance
Frequency (f): 1-500 MHz
Ohms
100 15
CROSS-WEB
INSULATION
RIP CORD
OUTER
JACKET
23 AWG
CONDUCTOR
GenSPEED

6500 PREMIUM CATEGORY 6


CROSS-SECTION
GenSPEED

6500 Electrical Performance


Frequency
MHz
PSACR* (min) ACR* (min) Insertion Loss (max) PSNEXT (min) NEXT (min)
Guaranteed Guaranteed
TIA
568-C.2
Guaranteed
TIA
568-C.2
Guaranteed
TIA
568-C.2
Guaranteed
1 77.4 79.4 2.0 1.9 72.3 79.3 74.3 81.3
4 66.8 68.8 3.8 3.5 63.3 70.3 65.3 72.3
10 58.8 60.8 6.0 5.5 57.3 64.3 59.3 66.3
16 54.2 56.2 7.6 7.0 54.2 61.2 56.2 63.2
20 51.9 53.9 8.5 7.8 52.8 59.8 54.8 61.8
31.25 47.0 49.0 10.7 9.9 49.9 56.9 51.9 58.9
62.5 38.0 40.0 15.4 14.3 45.4 52.4 47.4 54.4
100 30.8 32.8 19.8 18.5 42.3 49.3 44.3 51.3
200 17.5 19.5 29.0 27.2 37.8 44.8 39.8 46.8
250 12.4 14.4 32.8 30.9 36.3 43.3 38.3 45.3
350 3.5 5.5 37.6 41.1 43.1
500 46.5 38.8 40.8
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C. Results beyond 350 MHz for reference only.
*PSACR & ACR not specified in ANSI/TIA 568-C.2
Frequency
MHz
PSACRF (min) ACRF (min) Return Loss (min) TCL (min) ELTCTL (min)
TIA
568-C.2
Guaranteed
TIA
568-C.2
Guaranteed
TIA
568-C.2
Guaranteed
TIA
568-C.2
Guaranteed
TIA
568-C.2
Guaranteed
1 64.8 70.8 67.8 73.8 20.0 20.0 40.0 40.0 35.0 35.0
4 52.8 58.8 55.8 61.8 23.0 23.0 40.0 40.0 23.0 23.0
10 44.8 50.8 47.8 53.8 25.0 25.0 40.0 40.0 15.0 15.0
16 40.7 46.7 43.7 49.7 25.0 25.0 38.0 38.0 10.9 10.9
20 38.8 44.8 41.8 47.8 25.0 25.0 37.0 37.0 9.0 9.0
31.25 34.9 40.9 37.9 43.9 23.6 25.0 35.1 35.1 5.1
62.5 28.9 34.9 31.9 37.9 21.5 23.5 32.0 32.0 5.0
100 24.8 30.8 27.8 33.8 20.1 22.1 30.0 30.0 5.0
200 18.8 24.8 21.8 27.8 18.0 20.0 27.0 27.0 5.0
250 16.8 23.8 19.8 26.8 17.3 19.3 26.0 26.0 5.0
350 19.9 22.9 18.3
500 16.8 19.8 17.2
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C. Results beyond 350 MHz for reference only.
Home
26

Features And Benefits

Innovative cross-web design allowing for


maximum pair separation, increasing key
electrical performance parameters

Performance guaranteed to 350 MHz

TRU-Mark

print legend contains


footage markings from 1000' to 0'

Third-party verified for guaranteed


performance

Made in U.S.A.
Applications

IEEE 802.3: 1000 BASE-T (Gigabit


Ethernet), 100 BASE-TX, 10 BASE-T

ANSI/TIA/EIA 854: 1000 BASE-TX

155 Mp/s, 1.2 Gb/s ATM

ANSI X3.263: 100 Mb/s

IEEE 802.3af DTE Power (PoE)

IEEE 802.3at for PoE Plus

Digital Video

Broadband and Baseband Analog Video


Standard Compliances

ANSI/TIA 568-C.2

ANSI/TIA 862 (Building Automation)

ISO/IEC 11801 Ed. 2.0 (Class E)

ICEA S-102-700 (Category 6)

NEC/CEC Type CMR (UL 1666) for


Non-Plenum

NEC/CEC Type CMP (NFPA 262) for


Plenum

RoHS Compliant Directive 2002/95/EC

UL 444
PHYSICAL DATA
CMR (Non-Plenum) CMP (Plenum)
Nominal Cable Diameter (in) 0.235 0.225
Nominal Cable Weight (lbs/1000 ft) 28 31
Minimum Bend Radius (in) 1.0 1.0
Maximum Pulling Force (lbs) 32 32
Temperature Rating (C)
Installation: 0 to +60 0 to +60
Operation: -20 to +75 -20 to +75
Data subject to change without notice.
GenSPEED

6000 Enhanced Category 6 Cable


PART NUMBERS
Standard packaging: 1000' Pull-Pac

ll
Pull-Pac

Il Spool-Pac

Spool
Jacket Color
CMR
(Non-Plenum)
CMP
(Plenum)
CMR
(Non-Plenum)
CMP
(Plenum)
CMR
(Non-Plenum)
CMP
(Plenum)
Blue 7133900 7131900 7133940 7131940 7133960 7131960
White 7133901 7131901 7133941 7131941 7133961 7131961
Yellow 7133902 7131902 7133942 7131942 7133962 7131962
Gray 7133903 7131903 7133943 7131943 7133963 7131963
Red 7133904 7131904 7133944 7131944 7133964 7131964
Orange 7133905 7131905 7133945 7131945 7133965 7131965
Green 7133906 7131906 7133946 7131946 7133966 7131966
Black 7133907 7131907 7133947 7131947 7133967 7131967
Pink 7133908 7131908 7133948 7131948 7133968 7131968
Purple 7133909 7131909 7133959 7131959 7133969 7131969
Note: Bulk reels are available as a special request with a maximum allowable length of 3000 feet per reel. Minimum run and
lead time may apply.
Non-stock items may be subject to minimum order quantities.
CONSTRUCTION
Conductors
23 AWG solid bare annealed copper
Insulation
Non-Plenum: Polyolefin
Plenum: Fluoropolymer
Color Code
Pair 1: Blue-White/Blue
Pair 2: Orange-White/Orange
Pair 3: Green-White/Green
Pair 4: Brown-White/Brown
Separator
Cross-web
Rip Cord
Applied longitudinally under jacket
Jacket
Non-Plenum: Flame-Retardant PVC
Plenum: Low-Smoke, Flame-Retardant
PVC
TIA 568-C.2
Home
27

ELECTRICAL CHARACTERISTICS
DC Resistance (max)
Ohms/100 m (328 ft) @ 20C
8.9
DC Resistance Unbalance (max)
Individual Pair %
3.0
Delay Skew (max)
ns/100 m
CMP: 35
CMR: 40
Nom. Velocity of Propagation
% Speed of Light
CMP: 70
CMR: 68
Characteristic Impedance
Frequency (f): 1-500 MHz
Ohms
100 15
GenSPEED

6000 Electrical Performance


Frequency
MHz
PSACR* (min) ACR* (min) Insertion Loss (max) PSNEXT (min) NEXT (min)
Guaranteed Guaranteed
TIA
568-C.2
Guaranteed
TIA
568-C.2
Guaranteed
TIA
568-C.2
Guaranteed
1 75.3 77.3 2.0 2.0 72.3 77.3 74.3 79.3
4 64.5 66.5 3.8 3.8 63.3 68.3 65.3 70.3
10 56.4 58.4 6.0 5.9 57.3 62.3 59.3 64.3
16 51.7 53.8 7.6 7.5 54.2 59.3 56.2 61.3
20 49.4 51.4 8.5 8.4 52.8 57.8 54.8 59.8
31.25 44.3 46.3 10.7 10.6 49.9 54.9 51.9 56.9
62.5 35.1 37.1 15.4 15.3 45.4 50.4 47.4 52.4
100 27.6 29.6 19.8 19.7 42.3 47.3 44.3 49.3
150 20.0 22.0 24.7 24.7 39.7 44.7 41.7 46.7
200 13.8 15.8 29.0 29.0 37.8 42.8 39.8 44.8
250 8.7 10.7 32.8 32.6 36.3 41.3 38.3 43.3
350 1.7 39.5 39.2 41.2
500 48.6 36.8 38.8
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C. Results beyond 350 MHz for reference only.
*PSACR & ACR not specified in ANSI/TIA 568-C.2
Frequency
MHz
PSACRF (min) ACRF (min) Return Loss (min) TCL (min) ELTCTL (min)
TIA
568-C.2
Guaranteed
TIA
568-C.2
Guaranteed
TIA
568-C.2
Guaranteed
TIA
568-C.2
Guaranteed
TIA
568-C.2
Guaranteed
1 64.8 69.8 67.8 72.8 20.0 20.0 40.0 40.0 35.0 35.0
4 52.8 57.7 55.7 60.7 23.0 23.6 40.0 40.0 23.0 23.0
10 44.8 49.8 47.8 52.8 25.0 26.0 40.0 40.0 15.0 15.0
16 40.7 45.7 43.7 48.7 25.0 26.0 38.0 38.0 10.9 10.9
20 38.8 43.7 41.7 46.7 25.0 26.0 37.0 37.0 9.0 9.0
31.25 34.9 39.9 37.9 42.9 23.6 25.0 35.1 35.1 5.1
62.5 28.9 33.8 31.8 36.8 21.5 23.5 32.0 32.0 5.0
100 24.8 29.8 27.8 32.8 20.1 22.5 30.0 30.0 5.0
150 21.3 26.3 24.3 29.3 18.9 21.6 28.2 28.2 5.0
200 18.8 23.8 21.8 26.8 18.0 21.0 27.0 27.0 5.0
250 16.8 21.8 19.8 24.8 17.3 20.5 26.0 26.0 5.0
350 18.9 21.9 19.8
500 15.8 18.8 19.0
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C. Results beyond 350 MHz for reference only.
Optimally Balanced Enhanced Performance
GenSPEED

6000 ENHANCED CATEGORY 6


CROSS-SECTION
CROSS-WEB
INSULATION
RIP CORD
OUTER
JACKET
23 AWG
CONDUCTOR
Home
28
GenSPEED

6 Category 6 Cable
CONSTRUCTION
Conductors
23 AWG solid bare annealed copper
Insulation
Non-Plenum: Polyolefin
Plenum: Fluoropolymer/Dual-Layer
Polyolefin
Color Code
Pair 1: Blue-White/Blue
Pair 2: Orange-White/Orange
Pair 3: Green-White/Green
Pair 4: Brown-White/Brown
Separator
Divider
Rip Cord
Applied longitudinally under jacket
Jacket
Non-Plenum: Flame-Retardant PVC
Plenum: Low-Smoke, Flame-Retardant
PVC
PHYSICAL DATA
CMR (Non-Plenum) CMP (Plenum)
Nominal Cable Diameter (in) 0.205 0.200
Nominal Cable Weight (lbs/1000 ft) 28 28
Minimum Bend Radius (in) 1.0 1.0
Maximum Pulling Force (lbs) 32 32
Temperature Rating (C)
Installation: 0 to +60 0 to +60
Operation: -20 to +75 -20 to +75
Data subject to change without notice.
Features And Benefits

Unique separator design engineered for


consistent electrical performance

Performance guaranteed to 350 MHz

TRU-Mark

print legend contains


footage markings from 1000' to 0'

Third-party verified for guaranteed


performance

Made in U.S.A.
Applications

IEEE 802.3: 1000 BASE-T (Gigabit


Ethernet), 100 BASE-TX, 10 BASE-T

ANSI/TIA 854: 1000 BASE-TX

155 Mp/s, 1.2 Gb/s ATM

ANSI X3.263: 100 Mb/s

IEEE 802.3af DTE Power (PoE)

IEEE 802.3at for PoE Plus

Digital Video

Broadband and Baseband Analog Video


Standard Compliances

ANSI/TIA 568-C.2

ANSI/TIA 862 (Building Automation)

ISO/IEC 11801 Ed. 2.0 (Class E)

ICEA S-102-700 (Category 6)

NEC/CEC Type CMR (UL 1666) for


Non-Plenum

NEC/CEC Type CMP (NFPA 262) for


Plenum

RoHS Compliant Directive 2002/95/EC

UL 444
PART NUMBERS
Standard packaging: 1000' Pull-Pac

II
Pull-Pac

II Spool-Pac

Spool
Jacket Color
CMR
(Non-Plenum)
CMP
(Plenum)
CMR
(Non-Plenum)
CMP
(Plenum)
CMR
(Non-Plenum)
CMP
(Plenum)
Blue 7133800 7131800 7133840 7131840 7133860 7131860
White 7133801 7131801 7133841 7131841 7133861 7131861
Yellow 7133802 7131802 7133842 7131842 7133862 7131862
Gray 7133803 7131803 7133843 7131843 7133863 7131863
Red 7133804 7131804 7133844 7131844 7133864 7131864
Orange 7133805 7131805 7133845 7131845 7133865 7131865
Green 7133806 7131806 7133846 7131846 7133866 7131866
Black 7133807 7131807 7133847 7131847 7133867 7131867
Pink 7133808 7131808 7133848 7131848 7133868 7131868
Purple 7133809 7131809 7133859 7131859 7133869 7131869
Note: Bulk reels are available as a special request with a maximum allowable length of 3000 feet per reel. Minimum run and
lead time may apply.
Non-stock items may be subject to minimum order quantities.
TIA 568-C.2
Home
29
ELECTRICAL CHARACTERISTICS
DC Resistance (max)
Ohms/100 m (328 ft) @ 20C
8.9
DC Resistance Unbalance (max)
Individual Pair %
3.0
Delay Skew (max)
ns/100 m
45
Nom. Velocity of Propagation
% Speed of Light
CMP: 70
CMR: 68
Characteristic Impedance
Frequency (f): 1-350 MHz
Ohms
100 15
GenSPEED

6 Electrical Performance ANSI/ TIA 568-C.2


Frequency
MHz
PSACR*
(min)
ACR*
(min)
Insertion Loss
(max)
PSNEXT
(min)
NEXT
(min)
PSACRF
(min)
ACRF
(min)
Return Loss
(min)
TCL
(min)
ELTCTL
(min)
1 70.3 72.3 2.0 72.3 74.3 64.8 67.8 20.0 40.0 35.0
4 59.3 61.5 3.8 63.3 65.3 52.8 55.7 23.0 40.0 23.0
10 51.3 53.3 6.0 57.3 59.3 44.8 47.8 25.0 40.0 15.0
16 46.7 48.7 7.6 54.2 56.2 40.7 43.7 25.0 38.0 10.9
20 44.3 46.3 8.5 52.8 54.8 38.8 41.7 25.0 37.0 9.0
31.25 39.2 41.2 10.7 49.9 51.9 34.9 37.9 23.6 35.1
62.5 29.9 32.0 15.4 45.4 47.4 28.9 31.8 21.5 32.0
100 22.5 24.5 19.8 42.3 44.3 24.8 27.8 20.1 30.0
150 14.9 16.9 24.7 39.7 41.7 21.3 24.3 18.9 28.2
200 8.8 10.8 29.0 37.8 39.8 18.8 21.8 18.0 27.0
250 3.5 5.5 32.8 36.3 38.3 16.8 19.8 17.3 26.0
350 39.8 34.1 36.1 13.9 16.9 16.3
400 43.0 33.3 35.3 12.8 15.8 15.9
500 48.9 31.8 33.8 10.8 13.8 15.2
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C. Results beyond 350 MHz are for reference only.
*
PSACR & ACR not specified in ANSI/TIA 568-C.2
Standards-Compliant Extended Frequency
GenSPEED

6 CATEGORY 6 CROSS-SECTION
INSULATION
RIP CORD
OUTER
JACKET
23 AWG
CONDUCTOR
SEPARATOR
Home
30
PART NUMBERS
Standard packaging: 1000' Pull-Pac

Il with environmentally friendly packaging.


Spool-Pac

and Spool by special order.


Pull-Pac

Il Spool-Pac

Spool
Jacket Color
CMR
(Non-Plenum)
CMR
(Non-Plenum)
CMR
(Non-Plenum)
Blue 7133800-17F 7133840-17F 7133860-17F
White 7133801-17F 7133841-17F 7133861-17F
Yellow 7133802-17F 7133842-17F 7133862-17F
Gray 7133803-17F 7133843-17F 7133863-17F
Red 7133804-17F 7133844-17F 7133864-17F
Orange 7133805-17F 7133845-17F 7133865-17F
Green 7133806-17F 7133846-17F 7133866-17F
Black 7133807-17F 7133847-17F 7133867-17F
Purple 7133809-17F 7133859-17F 7133869-17F
Note: Bulk reels are available as a special request with a maximum allowable length of 3000 feet per reel. Minimum run and
lead time may apply.
Non-stock items may be subject to minimum order quantities.
Separator
Divider
Jacket
Non-Plenum: Zero-Halogen Polyolefin
PHYSICAL DATA
CMR (Non-Plenum)
Nominal Cable Diameter (in) 0.210
Nominal Cable Weight (lbs/1000 ft) 29
Minimum Bend Radius (in) 1.0
Maximum Pulling Force (lbs) 32
Temperature Rating (C)
Installation: -10 to +60
Operation: -20 to +75
Conductors
23 AWG solid bare annealed copper
Insulation
Non-Plenum: Polyolefin
Color Code
Pair 1: Blue-White/Blue
Pair 2: Orange-White/Orange
Pair 3: Green-White/Green
Pair 4: Brown-White/Brown
CONSTRUCTION
Data subject to change without notice.
Features And Benefits

No halogens

Less toxic

More environmentally friendly

Increased flexibility for easy installation

Unique tape design engineered for


consistent electrical performance

Performance guaranteed to 350 MHz

TRU-Mark

print legend contains


footage markings from 1000 to 0

Third-party verified for guaranteed


performance

Made in U.S.A.
Applications

IEEE 802.3: 1000 BASE-T (Gigabit


Ethernet), 100 BASE-TX, 10 BASE-T

ANSI/TIA/EIA 854: 1000 BASE-TX

155 Mp/s, 1.2 Gb/s ATM

ANSI X3.263: 100 Mb/s

IEEE 802.3af DTE Power (PoE)

IEEE 802.3at for PoE Plus

Digital Video

Broadband and Baseband Analog Video


Standard Compliances

ANSI/TIA 568-C.2

ANSI/TIA 862 (Building Automation)

ISO/IEC 11801 Ed. 2.0 (Class E)

ICEA S-102-700 (Category 6)

NEC/CEC Type CMR (UL 1666) for


Non-Plenum

RoHS Compliant Directive 2002/95/EC

UL 444

IEC 60754-2
GenSPEED

6 with 17 FREE

Category 6 Cable
TIA 568-C.2
Home
31
ELECTRICAL CHARACTERISTICS
DC Resistance (max)
Ohms/100 m (328 ft) @ 20C
8.9
DC Resistance Unbalance (max)
Individual Pair %
3.0
Delay Skew (max)
ns/100 m
45
Nom. Velocity of Propagation
% Speed of Light
CMR: 68
Characteristic Impedance
Frequency (f): 1-350 MHz
Ohms
100 15
GenSPEED

6 with 17 FREE

Electrical Performance
Frequency
MHz
PSACR*
(min)
ACR*
(min)
Insertion Loss
(max)
PSNEXT
(min)
NEXT
(min)
PSACRF
(min)
ACRF
(min)
Return Loss
(min)
TCL
(min)
ELTCTL
(min)
1 70.3 72.3 2.0 72.3 74.3 64.8 67.8 20.0 40.0 35.0
4 59.3 61.5 3.8 63.3 65.3 52.8 55.7 23.0 40.0 23.0
10 51.3 53.3 6.0 57.3 59.3 44.8 47.8 25.0 40.0 15.0
16 46.7 48.7 7.6 54.2 56.2 40.7 43.7 25.0 38.0 10.9
20 44.3 46.3 8.5 52.8 54.8 38.8 41.7 25.0 37.0 9.0
31.25 39.2 41.2 10.7 49.9 51.9 34.9 37.9 23.6 35.1
62.5 29.9 32.0 15.4 45.4 47.4 28.9 31.8 21.5 32.0
100 22.5 24.5 19.8 42.3 44.3 24.8 27.8 20.1 30.0
150 14.9 16.9 24.7 39.7 41.7 21.3 24.3 18.9 28.2
200 8.8 10.8 29.0 37.8 39.8 18.8 21.8 18.0 27.0
250 3.5 5.5 32.8 36.3 38.3 16.8 19.8 17.3 26.0
350 39.8 34.1 36.1 13.9 16.9 16.3
400 43.0 33.3 35.3 12.8 15.8 15.9
500 48.9 31.8 33.8 10.8 13.8 15.2
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C. Results beyond 350 MHz are for reference only.

Spec meets ANSI/TIA/EIA 568-C.2 standard for Cat 6 UTP cabling.
*PSACR & ACR not specified in ANSI/TIA 568-C.2
INSULATION
OUTER
JACKET
23 AWG
CONDUCTOR
SEPARATOR
GenSPEED

6 with 17 FREE

CATEGORY 6
CROSS-SECTION
Going Green with General Cable
General Cable has accelerated its environmental commitment, addressing its green alternative approach
by identifying greener opportunities and promoting green cabling solutions wherever feasible. This includes
promoting our existing green products, partnering with key customers in their green endeavors, identifying
and providing resources for green product gaps, becoming a member of the U.S. Green Building Council
(USGBC) and participating in collaborative ventures such as the Green Suppliers Network (GSN).
Standards-Compliant
Home
32
GenSPEED

6 Category 6 Interlock Armored Cable


PHYSICAL DATA
CMR (Non-Plenum)
1 Cable
Nominal Cable Diameter (in) 0.450
Nominal Cable Weight (lbs/1000 ft) 67.8
Minimum Bend Radius (in) 1.0
Maximum Pulling Force (lbs) 32
Temperature Rating (C)
Installation: 0 to +60
Operation: -20 to +75
CONSTRUCTION
Conductors
23 AWG solid bare annealed copper
Insulation
Polyolefin
Rip Cord
Applied longitudinally under jacket
Color Code
Pair 1: Blue-White/Blue
Pair 2: Orange-White/Orange
Pair 3: Green-White/Green
Pair 4: Brown-White/Brown
Jacket
Flame-Retardant PVC
PART NUMBERS
Spool
Color Part Number Unit 1 Reel
Blue 9133300 6R Blue 1000' reel
Blue 9133300.2R 6R Blue 2000' reel
White 9133305 6R White 1000' reel
White 9133305.2R 6R White 2000' reel
Data subject to change without notice.
Features And Benefits

Interlock armor provides outstanding


mechanical protection

Flexible and easy to install

Eliminates the need for conduit, reducing


installation time

Single-pull installation

Application assurance warranty

Made in U.S.A.
Applications

IEEE 802.3: 1000 BASE-T (Gigabit


Ethernet), 100 BASE-TX, 10 BASE-T

ANSI/TIA/EIA 854: 100 BASE-TX

155 Mp/s, 1.2 Gb/s ATM

ANSI X3.263: 100 Mb/s

Indoor applications only


Standard Compliances

ANSI/TIA 568-C.2

ANSI/TIA 862 (Building Automation)

ISO/IEC 11801 Ed. 2.0 (Class E)

ICEA S-102-700 (Category 6)

NEC/CEC Type CMR (UL 1666)


for Non-Plenum

RoHS Compliant Directive 2002/95/EC

UL 444
TIA 568-C.2
Home
33
Standards-Compliant
ELECTRICAL PERFORMANCE
PSACR*
(min)
ACR*
(min)
Insertion
Loss
(max)
PSNEXT
(min)
NEXT
(min)
PSACRF
(min)
ACRF
(min)
Return
Loss
(min)
TCL
(min)
ELTCTL
(min)
1 70.3 72.3 2.0 72.3 74.3 64.8 67.8 20.0 40.0 35.0
4 59.3 61.5 3.8 63.3 65.3 52.8 55.7 23.0 40.0 23.0
10 51.3 53.3 6.0 57.3 59.3 44.8 47.8 25.0 40.0 15.0
16 46.7 48.7 7.6 54.2 56.2 40.7 43.7 25.0 38.0 10.9
20 44.3 46.3 8.5 52.8 54.8 38.8 41.7 25.0 37.0 9.0
31.25 39.2 41.2 10.7 49.9 51.9 34.9 37.9 23.6 35.1
62.5 29.9 32.0 15.4 45.4 47.4 28.9 31.8 21.5 32.0
100 22.5 24.5 19.8 42.3 44.3 24.8 27.8 20.1 30.0
150 14.9 16.9 24.7 39.7 41.7 21.3 24.3 18.9 28.2
200 8.8 10.8 29.0 37.8 39.8 18.8 21.8 18.0 27.0
250 3.5 5.5 32.8 36.3 38.3 16.8 19.8 17.3 26.0
350 39.8 34.1 36.1 13.9 16.9 16.3
400 43.0 33.3 35.3 12.8 15.8 15.9
500 48.9 31.8 33.8 10.8 13.8 15.2
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C. Results beyond 350 MHz for reference only.
*PSACR & ACR not specified in ANSI/TIA 568-C.2
GenSPEED

6 INTERLOCK ARMORED CABLE


CROSS-SECTION
CROSS-WEB
INSULATION
RIP CORD
OUTER
JACKET
23 AWG
CONDUCTOR
ALUMINUM
INTERLOCK
ARMOR
ELECTRICAL CHARACTERISTICS
DC Resistance (max)
Ohms/100 m (328 ft) @ 20C
9.38
DC Resistance Unbalance (max)
Individual Pair %
3.0
Delay Skew (max)
ns/100 m
45
Nom. Velocity of Propagation
% Speed of Light
CMR: 70
Characteristic Impedance
Frequency (f): 1-250 MHz
Ohms
100 15
Home
34
GenSPEED

6 Category 6 Outside Plant Cable


PHYSICAL DATA
Nominal Cable Diameter (in) 0.250
Nominal Cable Weight (lbs/1000 ft) 25
Minimum Bend Radius (in) 1.0
Maximum Pulling Force (lbs) 32
Temperature Rating (C)
Installation: -30 to +60
Operation: -45 to +80
CONSTRUCTION
Conductors
23 AWG solid bare annealed copper
Insulation
Polyolefin
Color Code
Pair 1: Blue-White/Blue
Pair 2: Orange-White/Orange
Pair 3: Green-White/Green
Pair 4: Brown-White/Brown
Separator
Cross-web
Flooding Compound
Waterproof gel
Jacket
UV- and Abrasion-Resistant
Polyethylenes
PART NUMBER
Standard packaging: 1000' Reel
Jacket Color Reel
Black 7136100
Features And Benefits

Innovative cross-web design allowing for


maximum pair separation, increasing key
electrical performance parameters

Gel-filled construction to prevent


moisture migration in underground and
wet applications

Wide temperature range for extreme


weather environments

TRU-Mark

print legend contains


footage markings from 1000' to 0'

Made in U.S.A.
Applications

Data transmission rates up to 2.4 Gb/s

1000 BASE-T (Gigabit Ethernet)

100/10 BASE-T (IEEE 802.3)

52/155 Mbps ATM

Duct and conduit installations

Not to be used aerially or direct buried


Standard Compliances

ANSI/TIA 568-C.2

ISO 11801 (Category 6)

ICEA S-102-700 (Category 6)

Telcordia (Bellcore) Specification GR-421-


CORE Water Penetration
Requirement

RoHS Compliant Directive 2002/95/EC


Data subject to change without notice.
TIA 568-C.2
Home
35
Enhanced Outdoor Performance
ELECTRICAL PERFORMANCE
Frequency
MHz
PSACR*
(min)
ACR*
(min)
Insertion Loss
(max)
PSNEXT
(min)
NEXT
(min)
PSACRF
(min)
ACRF
(min)
Return Loss
(min)
1 70.3 72.3 2.0 72.3 74.3 64.8 67.8 20.0
4 59.3 61.5 3.8 63.3 65.3 52.8 55.7 23.0
10 51.3 53.3 6.0 57.3 59.3 44.8 47.8 25.0
16 46.7 48.7 7.6 54.2 56.2 40.7 43.7 25.0
20 44.3 46.3 8.5 52.8 54.8 38.8 41.7 25.0
31.25 39.2 41.2 10.7 49.9 51.9 34.9 37.9 23.6
62.5 29.9 32.0 15.4 45.4 47.4 28.9 31.8 21.5
100 22.5 24.5 19.8 42.3 44.3 24.8 27.8 20.1
200 8.8 10.8 29.0 37.8 39.8 18.8 21.8 18.0
250 3.5 5.5 32.8 36.3 38.3 16.8 19.8 17.3
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C.
*PSACR & ACR not specified in ANSI/TIA 568-C.2
GenSPEED

6 CATEGORY 6 OUTSIDE PLANT


CROSS-SECTION
OUTER
JACKET
CROSS-WEB
23 AWG
CONDUCTOR
FLOODING
ELECTRICAL CHARACTERISTICS
DC Resistance (max)
Ohms/100 m (328 ft) @ 20C
8.9
DC Resistance Unbalance (max)
Individual Pair %
3.0
Delay Skew (max)
ns/100 m
45
Nom. Velocity of Propagation
% Speed of Light
69
Characteristic Impedance
Frequency (f): 1-250 MHz
Ohms
100 15
Home
Index Page
GenSPEED

Category 5e
Quick Reference Guide 37
GenSPEED

5500
Premium
Category 5e Cable 38-39
GenSPEED

5350
Enhanced
Category 5e Cable 40-41
GenSPEED

5000
Category 5e Cable 42-43
GenSPEED

5000
with 17 FREE
TM

Category 5e Cable 44-45
GenSPEED

5000
Category 5e Interlock
Armored Cable 46-47
GenSPEED

5000
Category 5e
Screened Cable 48-49
GenSPEED

5000
Category 5e
Outside Plant Cable 50-51
GenSPEED

5000
Category 5e
Residential CMX
Outdoor-CMR Cable 52-53
GenSPEED

5000
Category 5e
Backbone 25 Pair Cable 54-55
GenSPEED

Category 5e cables are available in a wide variety of performance


levels and constructions. With many options to pick from, you can select
the GenSPEED Category 5e product that meets your specific performance
requirements.
GenSPEED

5500 Premium Category 5e cable ensures increased headroom,


lower bit-error rates and higher signal transmission quality. GenSPEED


5350 exceeds Category 5e transmission requirements, offering electrical
performance for 1000 BASE-T and beyond Ethernet applications.
With steady, continuous performance, GenSPEED

5000 meets Category 5e


requirements for present and future network requirements. Offered in a
variety of constructions, there is a GenSPEED 5000 cable for nearly every
application including backbone, horizontal, outside, outside plant and
residential cabling. General Cable also offers its 17 FREE line of riser-rated
GenSPEED 5000 cables, which may qualify for LEED credit from the U.S.
Green Building Council.
All GenSPEED cables are are safety listed to the NEC and CEC requirements,
and most are verified for electrical performance. This independent third-
party testing further confirms the quality and performance of all GenSPEED
Enhanced Cables.
GenSPEEDs installer-friendly design means that customers wont lose
valuable time and money. GenSPEED cables feature unique product-specific
packaging for easy identification and TRU-Mark

footage marking so installers


dont waste time pulling cable thats too short.
Through leadership and participation on industry committees, technical
expertise and a focus on cultivating strong relationships, General Cable
provides customers with first-class technical support and a competitive
advantage. General Cables comprehensive warranty program means that
all GenSPEED cables conform to standard specifications and are free from
defects in material and workmanship.
For more than a century and a half, General Cable has stayed ahead of
the industrys changing needs with products that meet future performance
requirements and provide the best value in cabling solutions.
GenSPEED

Category 5e Cables 3
36
Datacom
Home
STANDARD ENHANCED PREMIUM
JACKET
COLOR PACKAGE
Category 5e
GenSPEED

5000 (p. 42)


Category 5e
GenSPEED

5350 Enhanced (p. 40)


Category 5e
GenSPEED

5500 Premium (p. 38)


CMR CMP CMR CMP CMR CMP
Blue
Pull-Pac

5133299E 5131278E 6133712 6131690 6133299 6131278


Spool-Pac

5133374E 5131431E 6133707 6131688 6133403 6131433


Spool 5133300E 5131282E 6133703 6131686 6133282 6131282
Bulk* 5133300E.2.5R 5131282E.3R 6133703.2.5R 6131686.3R 6133282.2.5R 6131282.3R
White
Pull-Pac

5133255E 5131361E 6133713 6131691 6133255 6131361


Spool-Pac

5133342E 5131450E 6133708 6131689 6133339 6131449


Spool 5133250E 5131365E 6133704 6131687 6133492 6131618
Bulk* 5133250E.2.5R 5131365E.3R 6133704.2.5R 6131687.3R 6133492.2.5R 6131618.3R
Yellow
Pull-Pac

5133289E 5131379E 6133715 6131693 6133289 6131546


Spool-Pac

5133448E 5131546E 6133717 6131695 6133369 6131379


Spool 5131648E 6133719 6131697 6133348 6131382
Bulk* 5133251E.2.5R 5131648E.3R 6133719.2.5R 6131697.3R 6133348.2.5R 6131382.3R
Gray
Pull-Pac

5133200E 5131418E 6133714 6131692 6133200 6131418


Spool-Pac

5133329E 5131456E 6133716 6131694 6133331 6131619


Spool 5133204E 5131475E 6133718 6131696 6133334
Bulk*
Red
Pull-Pac

5133274E 5131477E 6133274 6131477


Spool-Pac

5133427E 5131553E 6131732 6131635


Spool 5131383E
Bulk*
Orange
Pull-Pac

5133383E 5131422E 6133761 6133746 6131422


Spool-Pac

6133383 6131576
Spool 5133667E 6131733
Bulk*
Green
Pull-Pac

5133512E 5131547E 6131699 6133512 6131547


Spool-Pac

5133693E 5131575E 6131731 6133615 6131575


Spool 5133649E 5131649E 6131700 6133616 6131757
Bulk* 5133649E.2.5R 5131649E.3R 6131700.3R 6133616.2.5R 6131757.3R
Black
Pull-Pac

5133696E 5131683E 6131707 6133696 6131683


Spool-Pac

6131829
Spool 5131689E
Bulk*
Pink
Pull-Pac

5133290E 5131380E 6133290 6131709


Spool-Pac

5133447E 5131478E 6133447 6131478


Spool 6133341
Bulk*
Purple
Pull-Pac

5133445E 5131730E 6133445 6131710


Spool-Pac

6133446
Spool
Bulk*
Note: Non-stock items may be subject to minimum order quantities.
* Bulk reels are available in 2000' (2R) and 3000' (3R) lengths.
GenSPEED

Category 5e Quick Reference Guide


37
Datacom GenSPEED

Category 5e Cables
Home
38
Conductors
23 AWG CMR solid bare annealed copper
24 AWG CMP solid bare annealed copper
Insulation
Non-Plenum: Polyolefin
Plenum: Fluoropolymer
Color Code
Pair 1: Blue-White/Blue
Pair 2: Orange-White/Orange
Pair 3: Green-White/Green
Pair 4: Brown-White/Brown
Rip Cord
Applied longitudinally under jacket
Jacket
Non-Plenum: Flame-Retardant PVC
Plenum: Low-Smoke, Flame-Retardant
PVC
GenSPEED

5500 Premium Category 5e Cable


Features And Benefits

Ensures increased headroom for future


applications, lower bit-error rates, and
higher signal transmission quality

Enhanced signal-to-noise ratio, improving


bit-error rate

Performance guaranteed to 350 MHz

TRU-Mark

print legend contains


footage markings from 1000' to 0'

Third-party verified for guaranteed


performance

Made in U.S.A.
Applications

IEEE 802.3: 1000 BASE-T (Gigabit


Ethernet), 100 BASE-TX, 10 BASE-T

155 Mp/s, 622 Mp/s ATM

ANSI X3.263: 100 Mb/s

IEEE 802.3af DTE Power (PoE)

IEEE 802.3at DTE for PoE Plus

Broadband and Baseband Analog Video


Standard Compliances

ANSI/TIA 568-C.2

ANSI/TIA 862 (Building Automation)

ISO/IEC 11801 Ed. 2.0 (Class D)

ICEA S-90-661 (Category 5e)

NEC/CEC Type CMR (UL 1666) for


Non-Plenum

NEC/CEC Type CMP (NFPA 262) for


Plenum

RoHS Compliant Directive 2002/95/EC

UL 444
CONSTRUCTION
PHYSICAL DATA
CMR (Non-Plenum) CMP (Plenum)
Nominal Cable Diameter (in) 0.220 0.190
Nominal Cable Weight (lbs/1000 ft) 24 21
Minimum Bend Radius (in) 1.0 1.0
Maximum Pulling Force (lbs) 25 25
Temperature Rating (C)
Installation: 0 to +60 0 to +60
Operation: -20 to +75 -20 to +75
PART NUMBERS
Standard packaging: 1000' Pull-Pac

Il
Pull-Pac

Il Spool-Pac

Spool
Jacket Color
CMR
(Non-Plenum)
CMP
(Plenum)
CMR
(Non-Plenum)
CMP
(Plenum)
CMR
(Non-Plenum)
CMP
(Plenum)
Blue 6133299 6131278 6133403 6131433 6133282 6131282
White 6133255 6131361 6133339 6131449 6133492 6131618
Yellow 6133289 6131546 6133369 6131379 6133348 6131382
Gray 6133200 6131418 6133331 6131619 6133334
Red 6133274 6131477 6131635
Orange 6133746 6131422 6133383 6131576
Green 6133512 6131547 6133615 6131575 6133616 6131757
Black 6133696 6131683 6131829
Pink 6133290 6131709 6133447 6131478 6133341
Purple 6133445 6131710 6133446
Note: Bulk reels are available as a special request with a maximum allowable length of 3000 feet per reel. Minimum run and
lead time may apply.
Non-stock items may be subject to minimum order quantities.
Data subject to change without notice.
TIA 568-C.2
Home
39
Enhanced Transmission Throughput
GenSPEED

5500 PREMIUM CATEGORY 5e


CROSS-SECTION
ELECTRICAL CHARACTERISTICS
DC Resistance (max)
Ohms/100 m (328 ft) @ 20C
8.9
DC Resistance Unbalance (max)
Individual Pair %
3.0
Delay Skew (max)
ns/100 m
45
Nom. Velocity of Propagation
% Speed of Light
CMP: 72
CMR: 70
Characteristic Impedance
Frequency (f): 1-350 MHz
Ohms
100 15
GenSPEED

5500 ELECTRICAL PERFORMANCE


Frequency
MHz
PSACR*
(min)
ACR*
(min)
Insertion Loss
(max)
PSNEXT
(min)
NEXT
(min)
PSACRF
(min)
ACRF
(min)
Return Loss
(min)
1 66.3 68.3 2.0 68.3 70.3 62.0 65.0 20.0
4 55.4 57.4 3.9 59.3 61.3 50.0 53.0 23.0
10 47.1 49.1 6.2 53.3 55.3 42.0 45.0 25.0
16 42.3 44.3 7.9 50.2 52.2 37.9 40.9 25.0
20 39.9 41.9 8.9 48.8 50.8 36.0 39.0 25.0
25 37.4 39.4 10.0 47.3 49.3 34.0 37.0 24.3
31.25 34.7 36.7 11.2 45.9 47.9 32.1 35.1 23.6
62.5 25.1 27.1 16.3 41.4 43.4 26.1 29.1 21.5
100 17.3 19.3 21.0 38.3 40.3 22.0 25.0 20.1
155 8.6 10.6 26.9 35.4 37.4 18.2 21.2 18.8
200 2.8 4.8 31.0 33.8 35.8 16.0 19.0 18.0
250 35.3 32.3 34.3 14.0 17.0 17.3
300 39.2 31.1 33.1 12.5 15.5 16.8
350 42.9 30.1 32.1 11.1 14.1 16.3
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C.
*PSACR & ACR not specified in ANSI/TIA 568-C.2
OUTER
JACKET
CONDUCTOR
INSULATION
RIP CORD
Home
40

GenSPEED

5350 Enhanced Category 5e Cable


PART NUMBERS
Standard packaging: 1000' Pull-Pac

Il
Pull-Pac

Il Spool-Pac

Spool
Jacket Color
CMR
(Non-Plenum)
CMP
(Plenum)
CMR
(Non-Plenum)
CMP
(Plenum)
CMR
(Non-Plenum)
CMP
(Plenum)
Blue 6133712 6131690 6133707 6131688 6133703 6131686
White 6133713 6131691 6133708 6131689 6133704 6131687
Yellow 6133715 6131693 6133717 6131695 6133719 6131697
Gray 6133714 6131692 6133716 6131694 6133718 6131696
Red 6131732
Orange 6133761 6131733
Green 6131699 6131731 6131700
Black 6131707
Pink
Purple
Note: Bulk reels are available as a special request with a maximum allowable length of 3000 feet per reel. Minimum run and
lead time may apply.
Non-stock items may be subject to minimum order quantities.
PHYSICAL DATA
CMR (Non-Plenum) CMP (Plenum)
Nominal Cable Diameter (in) 0.200 0.190
Nominal Cable Weight (lbs/1000 ft) 20 22
Minimum Bend Radius (in) 1.0 1.0
Maximum Pulling Force (lbs) 25 25
Temperature Rating (C)
Installation: 0 to +60 0 to +60
Operation: -20 to +75 -20 to +75
CONSTRUCTION
Conductors
24 AWG solid bare annealed copper
Insulation
Non-Plenum: Polyolefin
Plenum: Fluoropolymer
Color Code
Pair 1: Blue-White/Blue
Pair 2: Orange-White/Orange
Pair 3: Green-White/Green
Pair 4: Brown-White/Brown
Rip Cord
Applied longitudinally under jacket
Jacket
Non-Plenum: Flame-Retardant PVC
Plenum: Low-Smoke, Flame-Retardant
PVC
Features And Benefits

For applications that require optimal


Cat 5e performance with flexibility for
the future

Performance guaranteed to 350 MHz

TRU-Mark

print legend contains


footage markings from 1000' to 0'

Third-party verified for guaranteed


performance

Made in U.S.A.
Applications

IEEE 802.3: 1000 BASE-T (Gigabit


Ethernet), 100 BASE-TX, 10 BASE-T

155 Mp/s, 622 Mp/s ATM

ANSI X3.263: 100 Mb/s

IEEE 802.3af DTE Power (PoE)

IEEE 802.3at for PoE Plus

Broadband and Baseband Analog Video


Standard Compliances

ANSI/TIA 568-C.2

ANSI/TIA 862 (Building Automation)

ISO/IEC 11801 Ed. 2.0 (Class D)

ICEA S-90-661 (Category 5e)

NEC/CEC Type CMR (UL 1666) for


Non-Plenum

NEC/CEC Type CMP (NFPA 262) for


Plenum

RoHS Compliant Directive 2002/95/EC

UL 444
Data subject to change without notice.
TIA 568-C.2
Home
41
High Performance
ELECTRICAL CHARACTERISTICS
DC Resistance (max)
Ohms/100 m (328 ft) @ 20C
8.9
DC Resistance Unbalance (max)
Individual Pair %
3.0
Delay Skew (max)
ns/100 m
45
Nom. Velocity of Propagation
% Speed of Light
CMP: 72
CMR: 70
Characteristic Impedance
Frequency (f): 1-350 MHz
Ohms
100 15
GenSPEED

5350 ELECTRICAL PERFORMANCE


Frequency
MHz
PSACR*
(min)
ACR*
(min)
Insertion Loss
(max)
PSNEXT
(min)
NEXT
(min)
PSACRF
(min)
ACRF
(min)
Return Loss
(min)
1 63.3 64.3 2.0 65.3 66.3 61.0 64.0 20.0
4 52.3 53.3 4.0 56.3 57.3 49.0 52.0 23.0
10 43.9 44.9 6.4 50.3 51.3 41.0 44.0 25.0
16 39.1 40.1 8.1 47.2 48.2 36.9 39.9 25.0
20 36.6 37.6 9.2 45.8 46.8 35.0 38.0 25.0
25 34.0 35.0 10.3 44.3 45.3 33.0 36.0 24.3
31.25 31.3 32.3 11.6 42.9 43.9 31.1 34.1 23.6
62.5 21.6 22.6 16.8 38.4 39.4 25.1 28.1 21.5
100 13.6 14.6 21.7 35.3 36.3 21.0 24.0 20.1
155 4.7 5.7 27.7 32.4 33.4 17.2 20.2
200 32.0 30.8 31.8 15.0 18.0
250 36.4 29.3 30.3 13.0 16.0
300 40.5 28.1 29.1 11.5 14.5
350 44.3 27.1 28.1 10.1 13.1
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C.
*PSACR & ACR not specified in ANSI/TIA 568-C.2
GenSPEED

5350 ENHANCED CATEGORY 5e


CROSS-SECTION
OUTER
JACKET
24 AWG
CONDUCTOR
INSULATION
RIP CORD
Home
42
PART NUMBERS
Standard packaging: 1000' Pull-Pac

Il
Pull-Pac

Il Spool-Pac

Spool
Jacket Color
CMR
(Non-Plenum)
CMP
(Plenum)
CMR
(Non-Plenum)
CMP
(Plenum)
CMR
(Non-Plenum)
CMP
(Plenum)
Blue 5133299E 5131278E 5133374E 5131431E 5133300E 5131282E
White 5133255E 5131361E 5133342E 5131450E 5133250E 5131365E
Yellow 5133289E 5131379E 5133448E 5131546E 5131648E
Gray 5133200E 5131418E 5133329E 5131456E 5133204E 5131475E
Red 5133274E 5131477E 5133427E 5131553E 5131383E
Orange 5133383E 5131422E 5133667E
Green 5133512E 5131547E 5133693E 5131575E 5133649E 5131649E
Black 5133696E 5131683E 5131689E
Pink 5133290E 5131380E 5133447E 5131478E
Purple 5133445E 5131730E
Note: Bulk reels are available as a special request with a maximum allowable length of 3000 feet per reel. Minimum run and
lead time may apply.
Non-stock items may be subject to minimum order quantities.
Conductors
24 AWG solid bare annealed copper
Insulation
Non-Plenum: Polyolefin
Plenum: Fluoropolymer/Dual-Layer
Polyolefin
Rip Cord
Applied longitudinally under jacket
Color Code
Pair 1: Blue-White/Blue
Pair 2: Orange-White/Orange
Pair 3: Green-White/Green
Pair 4: Brown-White/Brown

Jacket
Non-Plenum: Flame-Retardant PVC
Plenum: Low-Smoke, Flame-Retardant
PVC
GenSPEED

5000 Category 5e Cable


Features And Benefits

Engineered to provide stable and


continuous performance

Performance guaranteed to 200 MHz

TRU-Mark

print legend contains


footage markings from 1000' to 0'

Third-party verified for guaranteed


performance

Made in U.S.A.
Applications

IEEE 802.3: 1000 BASE-T (Gigabit


Ethernet), 100 BASE-TX, 10 BASE-T

52/155 Mp/s ATM

ANSI X3.263: 100 Mb/s

IEEE 802.3af for DTE Power (PoE)

IEEE 802.3at for PoE Plus

Broadband & Baseband Analog Video


Standard Compliances

ANSI/TIA 568-C.2

ANSI/TIA 862 (Building Automation)

ISO/IEC 11801 Ed. 2.0 (Class D)

ICEA S-90-661 (Category 5e)

NEC/CEC Type CMR (UL 1666) for


Non-Plenum

NEC/CEC Type CMP (NFPA 262)


for Plenum

RoHS Compliant Directive 2002/95/EC

UL 444
CONSTRUCTION
PHYSICAL DATA
CMR (Non-Plenum) CMP (Plenum)
Nominal Cable Diameter (in) 0.200 0.180
Nominal Cable Weight (lbs/1000 ft) 19 21
Minimum Bend Radius (in) 1.0 1.0
Maximum Pulling Force (lbs) 25 25
Temperature Rating (C)
Installation: 0 to +60 0 to +60
Operation: -20 to +75 -20 to +75
Data subject to change without notice.
TIA 568-C.2
Home
43
Standards-Compliant
ELECTRICAL CHARACTERISTICS
DC Resistance (max)
Ohms/100 m (328 ft) @ 20C
8.9
DC Resistance Unbalance (max)
Individual Pair %
3.0
Mutual Capacitance (max)
pF/ft @ 1 KHz
17
Delay Skew (max)
ns/100 m
45
Nom. Velocity of Propagation
% Speed of Light
CMP: 72
CMR: 70
Characteristic Impedance
Frequency (f): 1-200 MHz
Ohms
100 15
GenSPEED

5000 ELECTRICAL PERFORMANCE TIA 568-C.2


Frequency
MHz
PSACR*
(min)
ACR*
(min)
Insertion Loss
(max)
PSNEXT
(min)
NEXT
(min)
PSACRF
(min)
ACRF
(min)
Return Loss
(min)
1 60.3 63.3 2.0 62.3 65.3 60.8 63.8 20.0
4 49.2 52.2 4.1 53.3 56.3 48.8 51.8 23.0
10 40.8 43.8 6.5 47.3 50.3 40.8 43.8 25.0
16 36.0 39.0 8.2 44.2 47.2 36.7 39.7 25.0
20 33.5 36.5 9.3 42.8 45.8 34.8 37.8 25.0
25 30.9 33.9 10.4 41.3 44.3 32.8 35.8 24.3
31.25 28.2 31.2 11.7 39.9 42.9 30.9 33.9 23.6
62.5 18.4 21.4 17.0 35.4 38.4 24.9 27.9 21.5
100 10.3 13.3 22.0 32.3 35.3 20.8 23.8 20.1
155 1.4 4.4 28.1 29.4 32.4 17.0 20.0
200 32.4 27.8 30.8 14.8 17.8
250 36.9 26.3 29.3 12.8 15.8
300 41.0 25.1 28.1 11.3 14.3
350 44.9 24.1 27.1 9.9 12.9
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C. Values above 200 MHz are for information only.
*
PSACR & ACR not specified in ANSI/TIA 568-C.2
GenSPEED

5000 CATEGORY 5e CROSS-SECTION


RIP CORD
OUTER
JACKET
24 AWG
CONDUCTOR
INSULATION
Home
44
PART NUMBERS
Standard packaging: 1000' Pull-Pac

Il with environmentally friendly packaging.


Spool-Pac

and Spool by special order.


Pull-Pac

Il Spool-Pac

Spool
Jacket Color
CMR
(Non-Plenum)
CMR
(Non-Plenum)
CMR
(Non-Plenum)
Blue 5133299E-17F 5133374E-17F 5133300E-17F
White 5133255E-17F 5133342E-17F 5133250E-17F
Yellow 5133289E-17F 5133448E-17F
Gray 5133200E-17F 5133329E-17F 5133204E-17F
Red 5133274E-17F 5133427E-17F
Orange 5133383E-17F 5133667E-17F
Green 5133512E-17F 5133693E-17F 5133649E-17F
Black 5133696E-17F
Purple 5133445E-17F
Note: Bulk reels are available as a special request with a maximum allowable length of 3000 feet per reel. Minimum run and
lead time may apply.
Non-stock items may be subject to minimum order quantities.
PHYSICAL DATA
CMR (Non-Plenum)
Nominal Cable Diameter (in) 0.200
Nominal Cable Weight (lbs/1000 ft) 22
Minimum Bend Radius (in) 1.0
Maximum Pulling Force (lbs) 25
Temperature Rating (C)
Installation: -10 to +60
Operation: -20 to +75
Conductors
24 AWG solid bare annealed copper
Insulation
Non-Plenum: Polyolefin
Color Code
Pair 1: Blue-White/Blue
Pair 2: Orange-White/Orange
Pair 3: Green-White/Green
Pair 4: Brown-White/Brown

Jacket
Non-Plenum: Zero-Halogen Polyolefin
CONSTRUCTION
Data subject to change without notice.
GenSPEED

5000 with 17 FREE

Category 5e Cable
Features And Benefits

No halogens

Less toxic

More environmentally friendly

Increased flexibility for easy installation

Engineered to provide stable and


continuous performance

Performance guaranteed to 200 MHz

TRU-Mark

print legend contains


footage markings from 1000 to 0

Third-party verified for guaranteed


performance

Made in U.S.A.
Applications

IEEE 802.3: 1000 BASE-T (Gigabit


Ethernet), 100 BASE-TX, 10 BASE-T

52/155 Mp/s ATM

ANSI X3.263: 100 Mb/s

IEEE 802.3af DTE Power (PoE)

IEEE 802.3at for PoE Plus

Broadband and Baseband Analog Video


Standard Compliances

ANSI/TIA 568-C.2

ANSI/TIA 862 (Building Automation)

ISO/IEC 11801 Ed. 2.0 (Class D)

ICEA S-90-661 (Category 5e)

NEC/CEC Type CMR (UL 1666) for


Non-Plenum

RoHS Compliant Directive 2002/95/EC

UL 444

IEC 60754-2
TIA 568-C.2
Home
45
ELECTRICAL CHARACTERISTICS
DC Resistance (max)
Ohms/100 m (328 ft) @ 20C
8.9
DC Resistance Unbalance (max)
Individual Pair %
3.0
Mutual Capacitance (max)
pF/ft @ 1 KHz
17
Delay Skew (max)
ns/100 m
45
Nom. Velocity of Propagation
% Speed of Light
CMR: 70
Characteristic Impedance
Frequency (f): 1-200 MHz
Ohms
100 15
GenSPEED

5000 with 17 FREE

CATEGORY 5e
CROSS-SECTION
OUTER
JACKET
24 AWG
CONDUCTOR
INSULATION
Standards-Compliant
GenSPEED

5000 with 17 FREE

ELECTRICAL PERFORMANCE
Frequency
MHz
PSACR*
(min)
ACR*
(min)
Insertion Loss
(max)
PSNEXT
(min)
NEXT
(min)
PSACRF
(min)
ACRF
(min)
Return Loss
(min)
1 60.3 63.3 2.0 62.3 65.3 60.8 63.8 20.0
4 49.2 52.2 4.1 53.3 56.3 48.8 51.8 23.0
10 40.8 43.8 6.5 47.3 50.3 40.8 43.8 25.0
16 36.0 39.0 8.2 44.2 47.2 36.7 39.7 25.0
20 33.5 36.5 9.3 42.8 45.8 34.8 37.8 25.0
25 30.9 33.9 10.4 41.3 44.3 32.8 35.8 24.3
31.25 28.2 31.2 11.7 39.9 42.9 30.9 33.9 23.6
62.5 18.4 21.4 17.0 35.4 38.4 24.9 27.9 21.5
100 10.3 13.3 22.0 32.3 35.3 20.8 23.8 20.1
155 1.4 4.4 28.1 29.4 32.4 17.0 20.0 18.8
200 32.4 27.8 30.8 14.8 17.8 18.0
250 36.9 26.3 29.3 12.8 15.8 17.3
300 41.0 25.1 28.1 11.3 14.3 16.8
350 44.9 24.1 27.1 9.9 12.9 16.3
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C. Values above 200 MHz are for information only.
Spec meets ANSI/TIA 568-C.2 standard for Cat 5e UTP cabling.
*PSACR & ACR not specified in ANSI/TIA 568-C.2
Going Green with General Cable
General Cable has accelerated its environmental commitment, addressing its green alternative approach
by identifying greener opportunities and promoting green cabling solutions wherever feasible. This includes
promoting our existing green products, partnering with key customers in their green endeavors, identifying
and providing resources for green product gaps, becoming a member of the U.S. Green Building Council
(USGBC) and participating in collaborative ventures such as the Green Suppliers Network (GSN).
Home
46
Reel
Color Part Number Unit 1 Unit 2 Reel
Blue 8133300 5000R Blue 1000' reel
Blue 8133300.2R 5000R Blue 2000' reel
Blue/Blue 8133301 5000R Blue 5000R Blue 1000' reel
Blue/Blue 8133301.2R 5000R Blue 5000R Blue 2000' reel
Blue/White 8133307 5000R Blue 5000R White 1000' reel
Blue/White 8133307.2R 5000R Blue 5000R White 2000' reel
White 8133305 5000R White 1000' reel
White 8133305.2R 5000R White 2000' reel
White/White 8133306 5000R White 5000R White 1000' reel
White/White 8133306.2R 5000R White 5000R White 2000' reel
PART NUMBERS
Conductors
24 AWG solid bare annealed copper
Insulation
Polyolefin
Rip Cord
Applied longitudinally under jacket
Color Code
Pair 1: Blue-White/Blue
Pair 2: Orange-White/Orange
Pair 3: Green-White/Green
Pair 4: Brown-White/Brown
Jacket
Flame-Retardant PVC
Armor
Aluminum interlock armor
GenSPEED

5000 Category 5e Interlock Armored Cable


Features And Benefits

Interlock armor provides outstanding


mechanical protection

Flexible and easy to install

Eliminates the need for conduit, reducing


installation time

Single-pull installation

Made in U.S.A.
Applications

IEEE 802.3: 1000 BASE-T (Gigabit


Ethernet), 100 BASE-TX, 10 BASE-T

52/155 Mp/s ATM

ANSI X3.263: 100 Mb/s

IEEE 802.3af DTE Power (PoE)

IEEE 802.3at for PoE Plus

Indoor applications only


Standard Compliances

ANSI/TIA 568-C.2

ANSI/TIA 862 (Building Automation)

ISO/IEC 11801 Ed. 2.0 (Class D)

ICEA S-90-661 (Category 5e)

NEC/CEC Type CMR (UL 1666) for


Non-Plenum

RoHS Compliant Directive 2002/95/EC


PHYSICAL DATA
CMR (Non-Plenum)
1 Cable 2 Cables
Nominal Cable Diameter (in) 0.450 0.620
Nominal Cable Weight (lbs/1000 ft) 58.5 96.0
Minimum Bend Radius (in) 1.0 1.0
Maximum Pulling Force (lbs) 25 25
Temperature Rating (C)
Installation:
Operation:
0 to +60
-20 to +75
CONSTRUCTION
Data subject to change without notice.
TIA 568-C.2
Home
47
GenSPEED

5000 CATEGORY 5e INTERLOCK


ARMORED CROSS-SECTION
Standards-Compliant
ELECTRICAL CHARACTERISTICS
DC Resistance (max)
Ohms/100 m (328 ft) @ 20C
8.9
DC Resistance Unbalance (max)
Individual Pair %
3.0
Mutual Capacitance (max)
pF/ft @ 1 KHz
17
Delay Skew (max)
ns/100 m
45
Nom. Velocity of Propagation
% Speed of Light
CMR: 70
Characteristic Impedance
Frequency (f): 1-100 MHz
Ohms
100 15
ELECTRICAL PERFORMANCE
Frequency
MHz
PSACR*
(min)
ACR*
(min)
Insertion Loss
(max)
PSNEXT
(min)
NEXT
(min)
PSACRF
(min)
ACRF
(min)
Return Loss
(min)
1 60.3 63.3 2.0 62.3 65.3 60.8 63.8 20.0
4 49.2 52.2 4.1 53.3 56.3 48.8 51.8 23.0
10 40.8 43.8 6.5 47.3 50.3 40.8 43.8 25.0
16 36.0 39.0 8.2 44.2 47.2 36.7 39.7 25.0
20 33.5 36.5 9.3 42.8 45.8 34.8 37.8 25.0
25 30.9 33.9 10.4 41.3 44.3 32.8 35.8 24.3
31.25 28.2 31.2 11.7 39.9 42.9 30.9 33.9 23.6
62.5 18.4 21.4 17.0 35.4 38.4 24.9 27.9 21.5
100 10.3 13.3 22.0 32.3 35.3 20.8 23.8 20.1
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C.
*PSACR & ACR not specified in ANSI/TIA 568-C.2
OUTER
JACKET
ALUMINUM
INTERLOCK
ARMOR
24 AWG
CONDUCTOR
INSULATION
RIP CORD
Home
48
Features And Benefits

Foil shield reduces electromagnetic


interference (EMI) for optimal
performance

TRU-Mark

print legend contains


footage markings from 1000' to 0'

Made in U.S.A.
Applications

1000 BASE-T (Gigabit Ethernet)

E52/155 Mbps ATM

E100/10 BASE-T (IEEE 802.3)

IEEE 802.3af DTE Power (PoE)

IEEE 802.3at for PoE Plus

T1

Voice
Standard Compliances

ANSI/TIA 568-C.2

ANSI/ICEA S-90-661 (Category 5e)

NEC/CEC Type CMR (UL 1666) for


Non-Plenum

NEC/CEC Type CMP (NFPA 262)


for Plenum

RoHS Compliant Directive 2002/95/EC

UL 444
CONSTRUCTION
Conductors
24 AWG solid bare annealed copper
Insulation
Non-Plenum: Polyolefin
Plenum: Fluoropolymer
Color Code
Pair 1: Blue-White/Blue
Pair 2: Orange-White/Orange
Pair 3: Green-White/Green
Pair 4: Brown-White/Brown
Core Tape
Polyester
Drain Wire
26 AWG stranded (7/34) solid tinned
copper
Shield
Polyester-backed aluminum foil
(aluminum side in)
Jacket
Flame-Retardant PVC
PHYSICAL DATA
CMR (Non-Plenum) CMP (Plenum)
Nominal Cable Diameter (in) 0.250 0.225
Nominal Cable Weight (lbs/1000 ft) 36 32
Minimum Bend Radius (in) 1.0 1.0
Maximum Pulling Force (lbs) 25 25
Temperature Rating (C)
Installation: 0 to +60 0 to +60
Operation: -20 to +75 -20 to +75
Data subject to change without notice.
PART NUMBERS
Standard packaging: 1000' Spool
Spool
Jacket Color CMR (Non-Plenum) CMP (Plenum)
Blue 2133496E 2131611E
White 2133774E 2131778E
Yellow 2133777E 2131777E
Gray 2133495E 2131673E
Red 2133778E 2131774E
Orange 2133776E 2131776E
Green 2133775E 2131775E
Black 2133779E 2131779E
GenSPEED

5000 Category 5e Screened Cable


TIA 568-C.2
Home
49
ELECTRICAL PERFORMANCE
Frequency
MHz
PSACR*
(min)
ACR*
(min)
Insertion Loss
(max)
PSNEXT
(min)
NEXT
(min)
PSACRF
(min)
ACRF
(min)
Return Loss
(min)
1 60.3 63.3 2.0 62.3 65.3 60.8 63.8 20.0
4 49.2 52.2 4.1 53.3 56.3 48.8 51.8 23.0
10 40.8 43.8 6.5 47.3 50.3 40.8 43.8 25.0
16 36.0 39.0 8.2 44.2 47.2 36.7 39.7 25.0
20 33.5 36.5 9.3 42.8 45.8 34.8 37.8 25.0
25 30.9 33.9 10.4 41.3 44.3 32.8 35.8 24.3
31.25 28.2 31.2 11.7 39.9 42.9 30.9 33.9 23.6
62.5 18.4 21.4 17.0 35.4 38.4 24.9 27.9 21.5
100 10.3 13.3 22.0 32.3 35.3 20.8 23.8 20.1
155 1.4 4.4 28.1 29.4 32.4 17.0 20.0
200 32.4 27.8 30.8 14.8 17.8
250 36.9 26.3 29.3 12.8 15.8
300 41.0 25.1 28.1 11.3 14.3
350 44.9 24.1 27.1 9.9 12.9
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20C. Values above 100 MHz are for information only.
*
PSACR & ACR not specified in ANSI/TIA 568-C.2
GenSPEED

5000 CATEGORY 5e SCREENED


CROSS-SECTION
ELECTRICAL CHARACTERISTICS
DC Resistance (max)
Ohms/100 m (328 ft) @ 20C
8.9
DC Resistance Unbalance (max)
Individual Pair %
3
Mutual Capacitance (max)
pF/ft @ 1 KHz
17
Delay Skew (max)
ns/100 m
45
Nom. Velocity of Propagation (NVP)
% Speed of Light
CMP: 72
CMR: 70
Characteristic Impedance
Frequency (f): 1-100 MHz
Ohms
100 15
JACKET
DRAIN WIRE
24 AWG
CONDUCTOR
SHIELD
INSULATION
POLYESTER
TAPE
Standards-Compliant
Home