Sie sind auf Seite 1von 25

Moxa Embedded Solution on

IEC 61850
Moxa Systems
August, 2009
Confidential
Theme
IEC 61850 with Smart Grid
Substation Automation Empowered
By IEC 61850
Moxa Solution
Summary
Confidential
Future of Power: Smart Grid
Everything is now based on electricity
Computers, Networks, Telecom, Medical,
Electric grid produces at least 40% of CO2
emissions
Aging electric grid contributes a 20% power
loss while delivering to end user
Confidential
Smart Grid Infrastructure
Electricity Dispatching
Control Center
Power
Generation
Transmission Distribution
Substation Automation
Customers
Distributed Energy Integrated
Advanced Metering Infrastructure
Source: EPRI Intelligrid
Confidential
Substation Automation in Smart Grid
Electricity Dispatching
Control Center
Electricity consumption, switchboard
operation, information gathering, station
decision making feedback
Grid intelligence strategic decision,
T&D automated management
Substation
Source: EPRI Intelligrid
Confidential
Current Power Automation Protocols
ModBus
ModBus
IEC 60870-5
DNP 3.0
DNP 3.0
Confidential
Protocol Trend for Power Automation
Newton Evans: 2005-2007
IEC 61850 is the
trend
54
4
6
52
28
6
28
2
10
16
12
10
12
6
0
20
40
60
80
IEC6
0870 -103
IEC61850 DNP
Serial
Modbus
Serial
DNP LAN Other
TCP/IP
IEC6
0870 -104
Current Planned
Migrating to
Ethernet-based
Confidential
Future Power Automation Protocols
ModBus
ModBus
IEC 60870-5
DNP 3.0
DNP 3.0
ModBus/TCP
ModBus/TCP
IEC 61850
DNP 3.0
LAN
DNP 3.0
LAN
Confidential
Substation Automation Empowered
By IEC 61850

Confidential
Benefits of IEC 61850 Power
Substation
IEC 61850
Protocol Integration
Easy
Maintenance
Time to Market
Confidential
Moxa Offering
Confidential
Moxa Embedded Solution
Confidential
Lead with IEC61850-3 Certified
Embedded Computer DA-681
DA-681-I-DPP-T
IEC 61850-3 Test
Confidential
Using DA-681 in IEC61850-3 Substation
Requirements
IEC61850-3 certified hardware
Multiple LANs to connect IED device and communicate
dispatch control center
Requires 100-240 AC/DC power input
19-inch rackmount, fanless design
Benefits
The DA-681 has 6 LANs for network redundancy and
centralized communication
Excellent patented heat dissipation design for use in
-40 ~ 75C environments
Serial port with isolation protection for integrating legacy RTU
into IEC 61850 substation
Dual power design to connect simultaneously to 100 VDC and
240 VAC power sources
Confidential
Features Briefing
Intel x86 1GHz CPU with 910GMLE chipset
Built-in DDR2 SDRAM and industrial-grade
DOM
19-inch rackmount installation, 1U high
6 Ethernet ports for network redundancy
2 USB 2.0 Host, supporting system boot up
4 Serial 232 & 8 RS-485 ports (wide baud rate)
CF/SATA interfaces for storage expansion
100 to 240V AC/DC power input
Dual power for redundant application
(DP/DPP model only)
Fanless and low power consumption design
Confidential
Challenges to Certify IEC 61850-3
Function Test
EMC Test
Wide Temperature Test
Anti-Vibration Test
Confidential
Unique Design to Conquer EMC Test
Confidential
Wide Temperature Know-How
Thermal Placement
Optimization of
Components
Natural-Convection
Chamber to Test
Wide Temperature
Components Database
Optimal Heat Transfer
Methods
Self Warming System
Confidential
Special Heat Dissipation Design
L-Type for Heat Dissipation
Confidential
System Throttling Design
High Temperature Solution: Dynamic Throttling Technique


time
User
Configurable
inside BIOS
Confidential
120 hours Uninterrupted Testing
Confidential
Production Quality Management
(Dynamic Burn-in)
High temp. (55~75dc)

Pilot Run 24~48hrs
Over 80% function test items are covered during burn-in test program.
Monitoring programs control the entire burn-in status,
and show the data for analysis.
Room temp. (30~40dc)

Mass Production 4~24hrs
Wide temp. (-40~85 dc)

W/T Product screen 24 hrs
Confidential
Anti-Vibration Tolerance Test
50 G Anti-Shock
5-500 MHz Anti-Vibration
Confidential
Summary
IEC 61850 is the trend in modern power substation
to integrate different standards in
Relay, Control, and Metering equipments

DA-681 is the best solution to fit in
Communication Processor and Back-end Host



Confidential
Thanks!

Das könnte Ihnen auch gefallen