Designed for use with FireBus FB-8000 Process Control
Systems and FB-8800 Safety Systems the 8913-PS-AC and the 8914-PS-AC are members of a family of DIN-rail mountable system and feld power supplies. The power supplies are primary controlled AC-DC and DC-DC fyback converters with a constant switching frequency of 130 kHz. The single step conversion of the line input voltage to a low output voltage and the power factor correction, results in an extremely high effciency. These power supplies have been designed to the latest industry requirements and standards and are ideal for use in demanding applications such as Fire & Gas Safety equipment in harsh environments, including in Zone 2 and Division 2 hazardous areas. Safety Standards The 8913-PS-AC and 8914-PS-AC power supplies cor- respond to class I equipment according to IEC/EN60950 They also comply with EN61010-1 and EN 50178 stan- dards and have been designed in accordance with these standards for: Building in on DIN-Rails or on a wall/panel Basic insulation between input and case, based on 250 VAC/350 VDC Double insulation between input and output, based on 250 VAC/350 V DC Operational insulation between the outputs The use in a pollution degree 2 environment (AC- input). Connecting the input to a primary circuit with a maximum transient rating of 2500 V (overvoltage class II based on a 110V primary circuit, overvolt- age class II based on a 230 V primary circuit). Mounting A rugged snap-ft device allows easy and reliable fxing onto various types of 35 mm DIN rail. A heavy duty DIN rail mounting kit is available for larger amplitude vibration environments (8413-FN-DN). A pair of mounting brackets are also available for screw fxing the unit to a fat panel (8414-FK-SU). The units have pluggable screw terminals providing easy access from the front panel. Key Features Certifed for use in SIL 2 applications (IEC 61508) Power factor correction with low harmonic distor- tion; negligibly low inrush current High immunity to transients and surges; and low electromagnetic emissions. Input over- and undervoltage lock-out and thermal protection Output overvoltage protection by a second control loop to ensure safe operation of the fnal system. All outputs are electrically isolated SELV1 circuits with low output noise. Proof against no-load, overload and short-circuits. Can operate at full load up to an ambient tempera- ture of 70C in free air. FireBus Systems, Inc. Model 8913-PS-AC & 8914-PS-AC System & Field Power Supplies Wide range AC to DC Power Supplies For use with FB-8800 Safety Logic Solver 09FCS084-A09 Power Supplies 8913-PS-AC System & Field PS 8914-PS-AC Field PS Environmental Classifcations: Class I, Division 2, Groups A, B, C & D T4 Certifcate: TV 01 ATEX 1774X Approved for: II 3 G EEx n A II T4 Certifcate: FM 3011821 Approved for: Class I, Div. 2, Groups A, B, C, D, T4 Temperature ranges: -40F (-40C) to 158F (+70C) (Max. Amb.) Relative humidity: 93%, 104F (40C) for 56 days 8913-PS-AC: ELECTRICAL EMC Compliance: EN 61000-2,3,4,5,6,11 EN 55011/22, EN 55014 Electrical Safety: EN 60950 INPUT Rated (nominal) input voltage 93 / 240 VAC; 47-65 Hz 100 / 240 VDC Operating input voltage: 85 / 264 VAC; 47-65 Hz 90 / 250 VDC Effciency: up to 87% Connections: 2-part pluggable con- nector Input protection: 6.3A slow blow fuse and voltage dependent resistor OUTPUTS Output 1 Voltage: 24.7 VDC 10% Output 1 Current: 5 A (nominal) Output 2 Voltage: 11.95 VDC 5% Output 2 Current: 5 A (nominal) Connections: 2-part pluggable con- nector Input-Output Isolation: 2800 VDC Holdup time (full rated load) 15 ms (typical) Thermal Protection: Reduced output power Supply health indicator: LED NOTE: Output 2 supports load sharing for redundancy. An external diode should be used with Output 1 if load sharing for redundancy is required. 8914-PS-AC: ELECTRICAL EMC Compliance: EN 61000-2,3,4,5,6,11 EN 55011/22,EN 55014 Electrical Safety: EN 60950 INPUT Rated (nominal) input voltage 93 / 240 VAC; 47-65 Hz 100 / 240 VDC Operating input voltage: 85 / 264 VAC; 47-65 Hz 90 / 250 VDC Effciency: up to 87% Connections: 2-part pluggable con- nector Input protection: 6.3A slow blow fuse and voltage dependent resistor OUTPUTS Output Voltage: 24.7 VDC 10% Output Current: 10 A (nominal) Connections: 2-part pluggable con- nector Input-Output Isolation: 2800 VDC Holdup time (full rated load) 15 ms (typical) Thermal Protection: Reduced output power Supply health indicator: LED NOTE: Output supports load sharing for redundancy. 8913-PS-AC & 8914-PS-AC MECHANICAL Mounting Methods: 35 mm x 7.5 mm T Section DIN rail Dimensions: 4.05 in (103.0 mm) width 5.43 in (138.0 mm) high 4.47 in (113.6 mm) deep Weight: Net 26.45 oz (750 g) Note: The information in this data sheet is given in good faith and consid- ered accurate at the time of printing, however, the company reserves the right to change specifcations of products at any time without prior notice. Ordering information: 8913-PS-AC System and Field Power Supply 8914-PS-AC Field Power Supply Copyright 2009 FireBus Systems, Inc. P. O. BOX 460269, Houston, TX 77056-8269 http://www.FireBusSystems.com.