This document provides calculations for sizing the wet bottom ash hopper jet pump system for the Vung Ang 1 Thermal Power Plant 2 x 600MW project in Vietnam. Key details include:
- The wet bottom ash hopper capacity required is 133.33 cubic meters and the provided capacity is 200 cubic meters.
- Two jet pumps will be used, each receiving an inlet flow of 90.91 cubic meters per hour from the hopper to evacuate ash at a total rate of 181.82 cubic meters per hour.
- The calculated motive water requirement at the jet pump inlets is 150 cubic meters per hour at a total dynamic head of 87 meters.
This document provides calculations for sizing the wet bottom ash hopper jet pump system for the Vung Ang 1 Thermal Power Plant 2 x 600MW project in Vietnam. Key details include:
- The wet bottom ash hopper capacity required is 133.33 cubic meters and the provided capacity is 200 cubic meters.
- Two jet pumps will be used, each receiving an inlet flow of 90.91 cubic meters per hour from the hopper to evacuate ash at a total rate of 181.82 cubic meters per hour.
- The calculated motive water requirement at the jet pump inlets is 150 cubic meters per hour at a total dynamic head of 87 meters.
This document provides calculations for sizing the wet bottom ash hopper jet pump system for the Vung Ang 1 Thermal Power Plant 2 x 600MW project in Vietnam. Key details include:
- The wet bottom ash hopper capacity required is 133.33 cubic meters and the provided capacity is 200 cubic meters.
- Two jet pumps will be used, each receiving an inlet flow of 90.91 cubic meters per hour from the hopper to evacuate ash at a total rate of 181.82 cubic meters per hour.
- The calculated motive water requirement at the jet pump inlets is 150 cubic meters per hour at a total dynamic head of 87 meters.
FUNCTION NAME SIGN DATE DRWN Poonam Singh 21.12.10 CHKD G.Ashok Kumar 21.12.10 APPD G.Ashok Kumar 21.12.10
DOCUMENT No. VA1-TATL-00100-M-M7-CAL-0001 SCALE REV C VIETNAM OIL AND GAS GROUP (PVN) POYRY ENERGY LTD VIETNAM MACHINERY INSTALLATION CORPORATION (LILAMA) Sl No Parameters Terms Units Formula Value Remarks 1 Bottom Ash T BA T/hr 20.00 As per Revised input Design Parameters, Attachment no.2 2 Deletd 3 Deleted 4 Total Coarse ash generation T CA T/hr 20.00 5 Ash Generation for 8 Hrs T/shift [8 x T CA ] 160.00 6 Density of Bottom Ash T/Cum 1.20 As per Revised input Design Parameters, Attachment no.2 7 Wet Bottom Ash Hopper Capacity required Q BAR m 3 133.33 8 Wet Bottom Ash Hopper Capacity Provided Q BAp m 3 200.00 Refer calculation no. VA1-TATL-00100-M-M7-CAL-0002 9 Evacuation Time t c Hrs 1.10 As per Revised input Design Parameters, Attachment no.2 10 Evacuation Rate Q c m 3 /hr [Q BAP / t c ] 181.82 11 No of J et Pumps working n Nos 2.00 12 Input to each J et Pump Q m 3 /hr [Q / n] 90 91 CALCULATION SHEET M-Lot7 Ash Handling Plant 100210/LILAMA-TECPRO dated 10.02.2010 Vietnam Oil and Gas Group (PVN) Poyry Energy Ltd Vietnam Machinery Installation Corporation (LILAMA) EPC Contractor Contract No. Owner Owner's Consultant Wet Bottom Ash Hopper Jet Pump Sizing Calculations Poonam Singh G. Ashok Kumar EPC Contractor Consultant Sub Contractor Tecpro Systems Limited DOC. NO. : VA1-TATL-00100-M-M7-CAL-0001 Project Title Pacakge Title REVISION : C DATE : 21.12.10 Vung Ang 1 Thermal Power Plant 2 x 600MW Fichtner GMBH & Co. Kg Subject Calculated By Reviewed and Approved By B C C 12 Input to each J et Pump Q J P m/hr [Q c / n] 90.91 13 Additional J etting water for flushing Q j m 3 /hr 15.00 14 Clinker Grinder Sealing water Q CG m 3 /hr 4.00 15 Total J et Pump inlet Q TJ P m 3 /hr [Q J P +Q j +Q CG ] 109.91 16 J et Pump discharge pipe NB 250.00 17 Pipe OD OD mm 273.10 18 Pipe thickness t mm 36.55 6mm pipe thk +20mm Basalt Lining thk +10.55 mm mortar Thk 19 Pipe ID ID mm 200.00 20 Pipe Area A m 2 0.03 21 Permissible velocity through the pipe V m/s 2.30 22 Permissible flow through the pipe Q m 3 /hr 260.23 23 Motive water (HP water) Q mot m 3 /hr [Q - Q TJ P ] 150.32 Q mot m 3 /hr 150.00 24 Specific gravity of conveying slurry S1 (Q+ash equivalent (54.54))/Q 1.210 Particle Density of Ash 2 T/ m3 25 Specific gravity of J et pump input slurry S (Q TJ P +ash equivalent (54.54))/Q TJ P 1.496 Particle Density of Ash 2 T/ m 3 26 Removal rate of J et Pump Q TJ P /S 73.457 Which includes other water from wet bottom ash hopper 27 Length of conveying pipe (Maximum distance considered) L M 330.00 28 No. of bends in pipe N b 9.00 B B B B 1 of 2 29 Equivalent pipe length L eq M 3.70 30 Friction loss in pipe per 1000m Hf M 26.95 31 Hf in slurry pipe (C =140) 8.99 32 Margin on Head [10%] H M 1.1 x Hf 9.89 33 Static head H st M 5.00 34 Total Drop T drop M [Hst +Hf] 14.89 By momentum eqn 35 Head required at J et Pump inlet MWC HxQ mot x0.30 =QxT drop 86.12 J et Pump efficiency =30% MWC = 87 36 Motive water required at Jet Pump inlet 150 m 3 /hr at 87 MWC B B 2 of 2