REFRIGERATOR CONTENTS

1. PRECAUTION
2. PRODUCT SPECIFICATION
3. STRUCTURE
4. SCHEMATIC-DIAGRAM
5. TEMPERATURE CONTROL
6. SPECIFICATIONS OF MAJOR
FUNCTIONAL PARTS
7. OPERATING PRINCIPLE OF MAJOR
COMPONENTS, AND INSPECTION
METHOD
8. HOW TO REPLACE MAJOR
COMPONENTS
9. TROUBLE-SHOOTING
10. REPLACEMENT PARTS LIST
REFRIGERATOR
RA18FH/RA18VH
RA20FH/RA20VH
CFC FREE
REV.01/AUG.2004
i
Table of Contents
1 Precauti ons
1-1 Safety Precautions
1-2 Servicing Precautions
2 Product Specification
3 Structure
3-1 Description of Components (Without Stand Table)
3-2 Description of Components (With Stand Table)
3-3 Product Installation (Without Stand Table)
3-4 Product Installation (With Stand Table)
4 Schematic-Diagram
4-1 Circuit-Diagram
4-2 Object-Diagram
5 Temperature Control
6 Specifications of Major Functional Parts
7 Operating principle of major components, and inspection method
7-1 Compressor Motor
7-2 Overload protector
7-3 Relay
7-4 Temperature control
8 How to replace major components
8-1 Refrigeration Cycle
8-2 Steps for replacing thermostat
8-3 Steps for replacing relay
8-4 Steps for replacing door
8-5 Steps for replacing compressor-evaporator unit
9 Trouble shooting
9-1 Compressor does not run at all(Does not cool at all)
9-2 Compressor does not run normally
9-3 Compressor runs normally but inside temperature does not drop at all
9-4 Compressor runs normally but inside temperature does not drop at a sufficiently low level
1-1
1-1
1-1
2-1
3-1
3-1
3-2
3-3
3-4
4-1
4-1
4-1
5-1
6-1
7-1
7-1
7-2
7-3
7-4
8-1
8-1
8-2
8-2
8-2
8-2
9-1
9-1
9-1
9-1
9-2
RA18FH/RA18VH/RA20FH/RA20VH
3-5 3-5 Circulation of Refrigerant
REV.01/AUG.2004
ii
RA18FH/RA18VH/RA20FH/RA20VH
10 Replacement Parts List
10-1 Door parts [RA18FH/RA18VH/RA20FH/RA20VH]
10-1-1 Door parts list
10-2 Freezing & Fresh compartment
10-2-1 Freezing & Fresh compartment list
10-3 Ass'y-Cabinet parts
10-3-1 Ass'y-Cabinet Part list
10-4 Ass'y-Water Dispenser Parts
10-4-1 Ass'y-water dispenser parts list
10-1
10-1
10-2
10-5
10-6
10-7
10-8
10-10
10-11
REV.01/AUG.2004
Only qualified service technicians who are thoroughly familiar with the refrigeration cycle and the
required safety checks should perform service operations in accordance with specified guidelines.
1. Prior to service, be sure to disconnect the product from its electrical power source by
removing the products electrical plug from the wall receptacle to preclude the possibility of
resultant personal injury and / or proporty damage.
2. Never attempt to modify or bypass circuit connections in ways not recommended by the
3. Do not use any extension cords or double adaptors.
4. For personal safety, this appliance must be properly grounded.
This refrigerator should not be grounded with a telephone line, gas pipe etc.
1-1
1 Precautions
1-1 Safety Precautions
1. When checking the electrical components, excluding the compressor with the cluster removed
from the compressor terminal pin, the electrical parts are in good conditions when the start
relay makes a "woong" sound as soon as power is applied.
2. In case of article No.1 and starting capacitor(inself only), do not supply power in order to check
for electrical charge and discharge for more than two minutes. When power is supplied for
more than two minutes, the insulation inside the capacitor may be broken. When it is impossible
to finish the test within two minutes, wait for about 30 minutes, and then check again.
3. When replacing the relay connected to the compressor terminal pin, be sure to pull it of
straight and push it on straight. Swaying of the relay side-to-side or up and down, may -cause
damage to the compressor terminal pin and / or the relay. .
4. Wait more than 5 minutes to re-start the refrigerator after stop it once
If you plug in the refrigerator immediately after you pull the plug, you may not be able to start it
again.
: o n the This is sa fe t y-r elat ed inform ation AC powe r c ircui ts and parts used in the refrigerator .
: This is informatio n required for repairing the refrigerator. .
1-2 Service precautions
RA18FH/RA18VH/RA20FH/RA20VH
manufacturer.
REV.01/AUG.2004
2-1
RA18FH/RA18VH/RA20FH/RA20VH
TYPE
CAPACITY
1 - DOOR REFRIGERATOR
540
599
KNOB(THERMOSTAT)
SEMI-AUTOMATIC(MANUAL START-AUTO FINISH OMA
URETHANE-FOAM (HCFC-141b) or CYCLOPENTANE(C
5
H
10
)
ABS(ES-0153 or SV-0157)
1
2 LEGS(NO STAND MODEL ONLY)
NET WEIGHT(Kg)
REFRIGERANT(g)
TEMPERATURE CONTROL
DEFROSTING
LINER/DOOR PANEL
NET
DIMESION
(mm)
WIDTH
DEPTH
HEIGHT
FOAM
ACCESSORY
PARTS
CABINET INSULATION
DOOR INSULATION
DOOR STORAGE
GROSS(LT/CU.FT)
180(6.4)
GROSS(LT/CU.FT)
200(7.1)
INSIDE STORAGE
INTERIOR LAMP
ANGLE ADJUSTMENT
1246(WITH STAND)
36.8/37.2
HFC-134a(120g)
1-GUARD EGG
2-GUARD VARIETY
1-GUARD BOTTLE
1-GUARD BOTTLE SMALL
1-TRAY ICE
1-TRAY CHILL ROOM
3-SHELF REF.
1-CASE VEGETABLE
38.0/38.5
HFC-134a(120g)
1156(WITHOUT STAND)
1340(WITH STAND)
1250(WITHOUT STAND)
1-TRAY EGG
1-GUARD DAIRY(Only RA18FH/RA20FH)
2 Product specification
MODEL RA18FH/RA18VH RA20FH/RA20VH
1-ASS'Y WATER TANK(Only RA18VH/RA20VH)
URETHANE-FOAM (HCFC-141b) or CYCLOPENTANE(C
5
H
10
)
3-1
3 Structure
3-1 Description of Components(Without Stand Table)
RA18FH/RA18VH/RA20FH/RA20VH
8
9
10
12
13
14
15
2
3
4
5
6
7
11
1
1 EVAP-ROLL BOND
2 TRAY ICE
3 DOOR FREEZER
4 TRAY CHILLED ROOM
5 SHELF-REF(CRYSTAL)
6 CASE-VEGETABLE
7 FOOT-FRONT
9 DOOR- SWITCH
10 TRAY EGG
11 GUARD-EGG
12 GUARD-DIALY
13 GUARD-VARIETY
8 KNOB-DIAL
14 GUARD-BOTTLE
15 GUARD BOTTLE SMALL
REV.01/AUG.2004
3 Structure
3-2 Description of Components (With Stand Table)
1 EVAP-ROLL BOND
2 TRAY ICE
3 DOOR FREEZER
4 TRAY CHILLED ROOM
5 SHELF-REF(CRYSTAL)
6 CASE-VEGETABLE
7 STAND TABLE
9 DOOR- SWITCH
10 TRAY EGG
11 GUARD-EGG
12 GUARD-DIALY
13 GUARD-VARIETY
3-2 RA18FH/RA18VH/RA20FH/RA20VH
8
9
10
12
13
14
15
2
3
4
5
6
7
11
8 KNOB-DIAL
14 GUARD-BOTTLE
15 GUARD BOTTLE SMALL
REV.01/AUG.2004
3-3
3 Structure
3-3 Product Installation(Without Stand Table)
RA18FH/RA18VH/RA20FH/RA20VH
* Dimensions in the parenthesis ( ) are RA20FH
544
1
0
9
6
(
1
1
9
0
)
1
1
5
6
(
1
2
5
0
)
544
1
1
5
6
(
1
2
5
0
)
1055
9
7
6
6
0
1
0
9
6
(
1
1
9
0
)
72
REV.01/AUG.2004
3-4
3 Structure
3-4 Product Installation(With Stand Table)
RA18FH/RA18VH/RA20FH/RA20VH
544
1
0
9
6
(
1
1
9
0
)
1
2
4
6
(
1
3
4
0
)
544
1
2
4
6
(
1
3
4
0
)
1
0
9
6
(
1
1
9
0
)
1
5
0
72
* Dimensions in the parenthesis ( ) are RA20FH
1055
9
7
6
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH
3 Structure
3-5 Circulation of Refrigerant
3-5
WELDING POINT CLASSIFICATION
: SILVER SOLDER WELDING
( 5% FOR Cu+Cu )
: FLASH BUTT WELDING (AL+CU)
: ARGON WELDING (AL+AL)
HOT PIPE
( 30% FOR Fe+Cu )
CLUSTER PIPE
CHARGING TUBE
CAPILLARY
EVAPORATOR
TUBE
COMPRESSOR
DRYER
SUCTION TUBE
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH
4 Schematic-Diagram
4-1 Circuit-Diagram
4-1
RA18FH/RA18VH/RA20FH/RA20VH
4-2 Object-Diagram
S/BLU
RUNNING
CAPACITOR
STARTING
-RELAY
COMPRESSOR
THERMOSTAT
LAMP
GRY
DOOR-
SWITCH
ORG RED
N A
OVERLOAD
-PROTECTOR
S/BLU - SKY/BLUE
RED - RED
ORG - ORANGE
GRY - GRAY
2
1
3
5
6
2
3
S
C
M
RA18FH/RA18VH/RA20FH/RA20VH
BLUE - BLUE
S/BLU - SKY/BLUE
RED - RED
ORG - ORANGE
GRY - GRAY
BLUE - BLUE
GRY
N
A
RED
RED
DOOR-
SWITCH
LAMP
C
S
M
S/BLU
BLUE
THERMOSTAT
GRY
ORG
ORG
3
2
1
2
BLUE
3
S/BLU
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH
5 Temperature control
5-1
Refrigerator temperature can be regulated by adjusting cold control. The closer to MAX position cold
control knob is set by rotating it clock wise, the lower becomes refrigerator temperature.
Refrigerator temperature will very depending on the quantity of the stored foods and on the frequncy
which the door is opened. Set cold control knob at MAX position only when ice cubes are need in
hurry.
This refrigerator may turn on and off more frequently than regular size refrigerator. This is normal
because of its compactness.
Push
Defrost
1
2
3
4
5
O
M
a
x
f
f
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH 6-1
6 Specifications of major function parts
ITEM STANDARD

MODEL
POWER SOURCE 110V 60Hz
C-BF 75L5Z
PTCS-CR
250cc
ROLLBOND TYPE
NATURAL CONVECTION(CLUSTER PIPE)
MOLECULAR SIEVE
ID0.67 x L2800(mm)
WSF19.5A-L
PTH7M220MD2
22 Ohm 20%
4TM174RHBYY-53
69 9
130 5
BSBN(BRASS SCREW)
REFRIGERA-
TION
CYCLE
ELECTRICAL
PARTS
MODEL
STARTING TYPE
OIL CHARGE
MODEL
RESISTANCE
MODEL
CLOSE TEMP (
O
C)
EVAPORATOR
CONDENSER
DRYER
CAPILLARY TUBE
THERMOSTAT
LAMP
DOOR SWITH
EARTH SCREW
COMPRESSOR
STARTING
RELAY
PROTECT-
OVERLOAD
RA18FH/RA18VH/RA20FH/RA20VH
127V 60Hz
250V/0.5A
125V/1.5A
220~240V 50Hz 220V 50/60Hz
3.5 mF,360 VAC RUNNING CAPACITOR
250V/0.5A
125V/1.5A
250V/0.5A
125V/1.5A
250V/0.5A
125V/1.5A
250V/0.5A
125V/1.5A
220V 60Hz
SD137H-LAZ2
RSIR
180cc
J531Q35E330M3852
33 Ohm 20%
4TM189SFBYY-53
61 9
135 5
240V/15W
-
OPEN TEMP (
O
C)
SD137C-L1U2
RSCR
180cc
J531Q32E6R8M1602
6.8 Ohm 20%
4TM317RHBYY-53
69 9
130 5
8mF,250 VAC
AZA1335YK-4R
RSCR
240cc
J531Q31C3R9M1602
4TM412LFBYY-53
70-52
105-115
4mF,440 VAC
3.9 Ohm 20%
C-BF 75L6Z
RSIR
250cc
4TM232RHBYY-53
PTH7M220MD2
33 Ohm 20%
-
69 9
130 5
110~127V/15W
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH
7 Operating principle of major components, and inspection method
7-1 Compressor Motor
7-1
Operating Principle Inspection method
The compressor motor, mounted directly to the
compressor and located inside a sealed steel
case, has two windings. One is a start winding
and the other a run winding. The windings are
connected together internally, forming a com-
mon connection.
A lead is connected to each of the windings,
and to the common connection. These three
leads are then connected to glass-sealed termi-
nals that extend through the compressor case.
The terminals are clustered in all triangle(pyra-
mid)pattern and, reading from left to right, are
identified: start, Common and Run.
Measure the resistance of each winding of
the compressor.
a. Disconnect the power cord.
b. Remove the relay from the compressor.
c. Measure the resistance of each winding.
The highest resistance value is the mea-
surement of the start and run terminals
whose windings are connected in series.
The lowest resistance
value is the
measurement of the
run and common
terminals.
The mid-level
resistance value is
the measurement of
the start and
common terminals.
B + C = A
Measure each
terminal and ground
with the ohmmetor
set to the highest
range. If a winding is
found to be either
open or shorted to
ground, the
compressor has failed.
1
A
B
C
2
7-2 Overload protector
Operating Principle Inspection method
The purpose of the relay of electric motor is to
prevent the electric motors coil from burning-out
due to a rise of abnormal temperature of
compressor and overload current. The overload
relay is connected in series with the common side
supplied with electric current with the main coil of
Above 100M
Insulation resistance
Use the tester to measure
the resistance.
- Bring the component to cool down
completely before measuring.
Normal
Approx 0.1~10 ohms
Abnormal
0 and

8ohms
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH 7-2
7 Operating principle of major components, and inspection method
Operating Principle Inspection method
electric motor of the compressor so that the coil is
to be protected in case of abnormal temperature of
overload current when starting or operationg
The overload protector is a protective device to
cut off the current of the electric motor by sepa-
rating the traveling contact and fixed contact
operating the compressor increases with the
over-load protector sticked fast to the compressor
and to break the current to the electric motor by
operating the bimetal heating the connected
heating in the event that the motor is charged
with over-load current.
7-3 Relay
Operating Principle Inspection method
The starting relay,positive temperature
coefficient-PTC, is used for compresser
starting in low current and high torque.
When power is first applied to the compresser
via the PTC-relay, the PTC pill is in low
resistance state. Current flows through the
PTC pill to the start windings, causing a
beneficial phase angle shift between start and
main windings, and resolting in an increase in
the starting torque. And when the compresser
start for a moment the current that supply via
the PCT-pill will make the temperature of PCT-
pill increasing. That will make the PTC-pill
change to high resistance state for
disconnecting the curcuit.
Disc
Movable-
arm
Heater Disc
Use the tester to measure
the resistance.
- Bring the component to cool down
completely before measuring.
Normal
Approx ~ kilo ohms
Abnormal
0 and

8ohms

8
4~100 ohms
(a) Internal structure
(b) Circuit diagram of electricity
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH 7-3
Operating Principle Inspection method
7-4 Temperature control
Operating Principle Inspection method
A temperature control is used on all refrigera-
tors and freezers to regulate the operation of
compressor and thus maintain desired food
temperatures. The temperature control consists
primarily of a capillary and bellows assembly, a
set of normally closed contacts, and a mechani-
cal linkage.
Pressure within the gas-charged capillary tube
and bellows assembly responds to temperature
sensed at the sensing bulb.
Rising temperature causes the pressure to
increase and expand the accordion-type bellows.
The expanded bellows actuates the linkage
which allows contracts to close.
When the temperature drops, the bellows con-
tracts due to a decrease in pressure and the
snap-action of the linkage opens the contacts.
Put the probe of the ohmmetor to the terminal
of the temperature control, and check for the
opening and closing of the contacts by turning
the knob ON and OFF.
7 Operating principle of major components, and inspection method
Cover
Male Quick Connect
Terminals
Pin Connector
PTC-Pill
Base
PTC-Pill Spring
Main
Sub
(a) Internal Structure
(b) Circuit Diagram of Electricity
2 5
3 6
REV.01/AUG.2004
COMPRESSOR :
CONDENSER :
DRYER :
CAPILLARY TUBE :
EVAPORATOR :
HEAT EXCHANGE BETWEEN SUCTION TUBE AND CAPILLARY TUBE :
THERMOSTAT :
STARTING RELAY :
OVERLOAD PROTECTOR :
In evap orator liquid refriger ant is so expanded to absorb heat around evap-
orator that compressor sucts refrigerant in low temperature and low pres-
sure and then compresses it to gaseous refrigerant in high temperature and
high pressure which will be discharged to outside.
Gaseous refrigerant in high temperature and in high pressure so radiates
evaporation latent heat absorbed from evaporator surrounding during pass-
ing through condenser and compression heat due to refrigerant gas com-
pression to surrounding of condenser that refrigerant becomes liquid in
high pr essure.
In order to prevent that moisture and foreign substances resided inside
every parts during refrigeration cycle assembling is so included among
refrigerant gas that it chokes the exit of inlet of capillary, dryer has drying
substances(molecular sieves) and filter inside it which absorbs or purify
them.
Regulates and/or keeps(in specified low) refrigerant flow rate so that
maintains constant pressure drop from wire condenser to evaporator.
Liquid refrigerant passed through capillary so expand in evaporator that it
becomes low temperature and low pressure to absorb heat around evapora-
tor, so that it chills surrounding air and at that time liquid refrigerant
becomes gaseous.
Liquid refrigerant in high temperature passing through capillaty tube so
changes heat between low temperature on suction tube and then more low-
ers liquid refrigerant temperature at just before expansion so that increases
its enthalpy to result big refrigeration efficiency at last.
Refrigerant gas in low temperature passing through suction tube so
exchanges heat between liquid refrigerant high temperature passing
through capillary that it becomes more high temperature condition and
then it becomes complete gaseous so that increase compression efficiency
of compressor.
Mounted inside the re frigerator to regulate the temperature of refrigerator.
When motor starts running owing to sub winding interrupts of current
simultaneously.
When circuit is overheated, it is cut off to prevent compressor wind
burn out.
RA18FH/RA18VH/RA20FH/RA20VH
8 How to replace major components
8-1 Refrigeration Cycle
8-1
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH
8 How to replace major components
8-2 Steps for replacing thermostat
1. Take off the control knob by pulling it forward.
2 . Take off the four screws fastening the control box.
3 . Take off the fastening the thermostat bulb
clamp on the bottom of evaporator.
1. Take off the cover of relay.
2. Take off the relay by pulling it to left-hand side.
8-2
8-3 Steps for replacing relay
Remove the two screws fastening the hinge-upper.
Then, door can be replaced.
8-4 Steps for replacing door
1 . Take off the cover-evap like as step 8-2.
2. Take off the screws on the ceiling of evaporator.
3. After melt the welding point by oxygen torch with
pulling evaporater, separate the evaporater from
suction pipe.
8-5 Steps for replacing compressor-evaporator unit
4. Take off the thermostat from cover-
evaporator hook.
1.
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH
9 Trouble-shooting
9-1 Compressor does not run at all(Does not cool at all)
9-1
9-2 Compressor does not run normally
Cause
Temperature control set to
position "OFF".
Erroneous plug cord inserting.
Fault relay assembly.
What to be checked
Check control knob setting.
Check plug cord inserting.
Check conduction of overload
relay.
Correction
Turn the control to
"COLD" (MAX) position.
Insert plug cord into outlet
correctly.
Replace if overload relay is not
conductive.
Cause
Source power voltage.
Starting voltage.
What to be checked
Check power voltage is within
10% of rating.
Check stating voltage.
Correction
If voltage is below rated value,
contact utility company.
If starting voltage drops below
10% of rating, contact utility
company and have household
wiring capacity increased.
9-3 Compressor runs normally but inside temperature does not drop at all
Cause
Faulty compressor-evaporator
unit.
What to be checked
After continuing operation for
over 20 minutes, let a drop of
water fall onto evaporator and
see if it becomes frozen.
Correction
Replace Compressor-evaporator
unit.
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH
9 Trouble-shooting
9-4 Compressor runs normally but inside temperature does not drop
at a sufficiently low level.
9-2
Cause
Erroneous temperature control
setting.
Faulty thermostat.
What to be checked
Check control knob setting.
Short-circuit thermostat termi-
nals and continue operation for
over 20 minutes. If temperature
drops, thermostat is faulty.
Correction
Set control to "COLD" and
continue operation for over 20
minutes. If temperature fails to
drop, do following.
Replace thermostat.
(If thermostat is not faulty.
compressor-evaporator unit is
in trouble).
Gaps between door and cabinet.
Check for gaps between door
packing and cabinet.
Loosen door gasket and
correct distortion of door.
Frosting on evaporator.
Check for excessive frosting on
evaporator. (This will deterio-
rate refrigerating efficiency).
Defrost before frost grows more
than 10 mm thick.
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH
10 Replacement parts list
10-1 Door parts
10-1
1
2
3
4
5
6
8
9
10
7
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH
10 Replacement parts list
10-1-1 Door part List
10-2
Code No No Description Specification
DA61-01500A
DA63-01874A 1
2
3
Base Handle
Cover Handle
ABS. Color SS
ABS. Color SW
ABS. Color MG
ABS. Color CG
ABS. Silver Spray 1
1
1
1
1
1
RA18
SS MG CG TT
RA20
SW NB SS MG CG TT SW NB
ABS. Color NB
DA61-01500B
DA61-01500C
DA61-01500D
DA61-01500E
Base Handle
Base Handle
Base Handle
Base Handle
1
1 1 1 1
1
1
1
1
1
1
1
1
1 1 1 1
1
Door Foam Assy DA91-01963A RA18VH,N-Key,Disp,SS (C-Pentane)
RA18VH,N-Key,Disp,SW (C-Pentane)
RA18VH,N-Key,Disp,MG (C-Pentane)
RA18VH,N-Key,Disp,CG (C-Pentane)
RA18VH,N-Key,Disp,NB (C-Pentane)
RA18VH,N-Key,Disp,TT (C-Pentane)
RA18FH,N-Key,N-Disp,SS (C-Pentane)
RA18FH,N-Key,N-Disp,SW (C-Pentane)
RA18FH,N-Key,N-Disp,MG (C-Pentane)
RA18FH,N-Key,N-Disp,CG (C-Pentane)
RA18FH,N-Key,N-Disp,NB (C-Pentane)
RA18FH,N-Key,N-Disp,TT (C-Pentane)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
RA18FH,Key,N-Disp,SS (C-Pentane)
RA18FH,Key,N-Disp,SW (C-Pentane)
RA18FH,Key,N-Disp,MG (C-Pentane)
RA18FH,Key,N-Disp,NB (C-Pentane)
RA18FH,Key,N-Disp,TT (C-Pentane)
1
1
1
1
1
RA20VH,N-Key,Disp,SS (C-Pentane)
RA20VH,N-Key,Disp,SW (C-Pentane)
RA20VH,N-Key,Disp,MG (C-Pentane)
RA20VH,N-Key,Disp,CG (C-Pentane)
RA20VH,N-Key,Disp,NB (C-Pentane)
RA20VH,N-Key,Disp,TT (C-Pentane)
RA20VH,Key,Disp,SS (C-Pentane)
RA20VH,Key,Disp,SW (C-Pentane)
RA20VH,Key,Disp,MG (C-Pentane)
RA20VH,Key,Disp,NB (C-Pentane)
RA20VH,Key,Disp,TT (C-Pentane)
RA20FH,N-Key,N-Disp,SS (C-Pentane)
RA20FH,N-Key,N-Disp,SW (C-Pentane)
RA20FH,N-Key,N-Disp,MG (C-Pentane)
RA20FH,N-Key,N-Disp,CG (C-Pentane)
1
1
1
1
1
1
1
1
1
1
1
DA91-01969F
DA91-01969G
DA91-01969H
DA91-01969J
DA91-01969K
DA91-01963B
DA91-01969R
DA91-01969S
DA91-01969T
DA91-01969U
DA91-01969V
DA91-01969L
DA91-01969M
DA91-01969N
DA91-01969P
DA91-01969Q
DA91-01963D
DA91-01968R
DA91-01968S
DA91-01968T
RA18VH,Key,Disp,SS (C-Pentane) DA91-01969A
RA18VH,Key,Disp,SW (C-Pentane) DA91-01969B
RA18VH,Key,Disp,MG (C-Pentane) DA91-01969C
RA18VH,Key,Disp,NB (C-Pentane) DA91-01969D
RA18VH,Key,Disp,TT (C-Pentane) DA91-01969E
1
1
1
1
1
1
1
1
1
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
DA91-01963C
DA91-01968F
DA91-01968G
DA91-01968H
DA91-01968J
DA91-01968K
DA91-01968A
DA91-01968B
DA91-01968C
DA91-01968D
DA91-01968E
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH
10 Replacement parts list
10-1-1 Door part List
10-3
Code No No Description Specification
DA91-01968U
3
Door Foam Assy RA20FH,N-Key,N-Disp,NB (C-Pentane)
1
1
1
RA18
SS TT SW MG CG NB SS TT SW MG CG NB
RA20
1
1
DA91-01968V Door Foam Assy RA20FH,N-Key,N-Disp,TT (C-Pentane)
DA91-01968L Door Foam Assy RA20FH,Key,N-Disp,SS (C-Pentane)
DA91-01968M Door Foam Assy RA20FH,Key,N-Disp,SW (C-Pentane)
DA91-01968N Door Foam Assy RA20FH,Key,N-Disp,MG (C-Pentane)
DA91-01968P Door Foam Assy RA20FH,Key,N-Disp,NB (C-Pentane)
DA91-01968Q Door Foam Assy RA20FH,Key,N-Disp,TT (C-Pentane)
1
1 1
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy DA91-01820A RA18VH,N-Key,Disp,SS (HCFC-141b)
RA18VH,N-Key,Disp,SW (HCFC-141b)
RA18VH,N-Key,Disp,MG (HCFC-141b)
RA18VH,N-Key,Disp,CG (HCFC-141b)
RA18VH,N-Key,Disp,NB (HCFC-141b)
RA18VH,N-Key,Disp,TT (HCFC-141b)
RA18FH,N-Key,N-Disp,SS (HCFC-141b)
RA18FH,N-Key,N-Disp,SW (HCFC-141b)
RA18FH,N-Key,N-Disp,MG (HCFC-141b)
RA18FH,N-Key,N-Disp,CG (HCFC-141b)
RA18FH,N-Key,N-Disp,NB (HCFC-141b)
RA18FH,N-Key,N-Disp,TT (HCFC-141b)
1
1
1
1
1
1
1
1
1
1
1
1
RA18FH,Key,N-Disp,SS (HCFC-141b)
RA18FH,Key,N-Disp,SW (HCFC-141b)
RA18FH,Key,N-Disp,MG (HCFC-141b)
RA18FH,Key,N-Disp,NB (HCFC-141b)
RA18FH,Key,N-Disp,TT (HCFC-141b)
1
1
1
1
1
RA20VH,N-Key,Disp,SS (HCFC-141b)
RA20VH,N-Key,Disp,SW (HCFC-141b)
RA20VH,N-Key,Disp,MG (HCFC-141b)
RA20VH,N-Key,Disp,CG (HCFC-141b)
RA20VH,N-Key,Disp,NB (HCFC-141b)
RA20VH,N-Key,Disp,TT (HCFC-141b)
1
1
1
1
1
1
DA91-01820G
DA91-01820H
DA91-01820J
DA91-01820K
DA91-01820L
DA91-01820B
DA91-01820S
DA91-01820T
DA91-01820U
DA91-01820V
DA91-01820W
DA91-01820X
DA91-01842A
DA91-01842B
DA91-01842C
DA91-01842D
DA91-01820E
DA91-01842E
DA91-01842F
DA91-01842G
DA91-01842H
DA91-01842J
Door Foam Assy RA18VH,Key,Disp,SS (HCFC-141b) DA91-01820M
Door Foam Assy RA18VH,Key,Disp,SW (HCFC-141b) DA91-01820N
Door Foam Assy RA18VH,Key,Disp,MG (HCFC-141b) DA91-01820P
Door Foam Assy RA18VH,Key,Disp,NB (HCFC-141b) DA91-01820Q
Door Foam Assy RA18VH,Key,Disp,TT (HCFC-141b) DA91-01820R
1
1
1
1
1
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
Door Foam Assy
RA20VH,Key,Disp,SS (HCFC-141b)
RA20VH,Key,Disp,SW (HCFC-141b)
RA20VH,Key,Disp,MG (HCFC-141b)
RA20VH,Key,Disp,NB (HCFC-141b)
RA20VH,Key,Disp,TT (HCFC-141b)
RA20FH,N-Key,N-Disp,SS (HCFC-141b)
RA20FH,N-Key,N-Disp,SW (HCFC-141b)
RA20FH,N-Key,N-Disp,MG (HCFC-141b)
RA20FH,N-Key,N-Disp,CG (HCFC-141b)
1
1
1
1
1
DA91-01842K
DA91-01842L
DA91-01842M
DA91-01842N
DA91-01842P
DA91-01820F
DA91-01842Q
DA91-01842R
DA91-01842S
1
1
1
1
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH
10 Replacement parts list
10-1-1 Door part List
10-4
Code No No Description Specification
3
RA18
SS TT SW MG CG NB SS TT SW MG CG NB
RA20
DA63-01870A
DA63-01959A
DA63-01872A
DA63-01871A
DA63-01960A
6
7
9
10
Guard Egg
Guard Daily
Guard Variety
Guard Bottle
Guard Bottle Small
GPPS
GPPS (FH-Model Only)
GPPS
GPPS
GPPS
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2 8
1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1
DA63-01886A Gasket Door RA18,PVC
4
DA63-01882A Tray Egg GPPS 5
DA63-01886B Gasket Door RA20,PVC
1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1
DA91-01842T Door Foam Assy RA20FH,N-Key,N-Disp,NB (HCFC-141b)
1
1
1
1
1
DA91-01842U Door Foam Assy RA20FH,N-Key,N-Disp,TT (HCFC-141b)
DA91-01842V Door Foam Assy RA20FH,Key,N-Disp,SS (HCFC-141b)
DA91-01842W Door Foam Assy RA20FH,Key,N-Disp,SW (HCFC-141b)
DA91-01842X Door Foam Assy RA20FH,Key,N-Disp,MG (HCFC-141b)
DA91-01842Y Door Foam Assy RA20FH,Key,N-Disp,NB (HCFC-141b)
DA91-01842Z Door Foam Assy RA20FH,Key,N-Disp,TT (HCFC-141b)
1
1
RA18FH/RA18VH/RA20FH/RA20VH
10 Replacement parts list
10-2 Freezing/Fresh Compartment
10-5
1
2
3
4
5
6
7
9
13
11
12
A
14
8
10
C
B
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH
10 Replacement parts list
10-2-1 Freezing / Fresh Compartment List
10-6
Code No No Description Specification
DA64-01086A
DA63-01875A
DA96-00113A
DA64-01093A
DA64-01092A
DA47-00146B
DA47-40117A
DA47-00086A
4713-000185
4713-001037
4713-001035
4713-000213
DA71-20275A
DA63-01883A
DA34-10121A
DA67-00848A
DA63-01876A
DA61-01501A
1
2
4
5
6
7
8
10
13
14
Evap.Roll Bond
Door Freezer
Knob Dial
Thermostat
Lamp Holder
Lamp Holder
Lamp
Lamp
Lamp
Lamp
Fixer Thermo
Tray Ice
Switch Door
Drain Hose Connect
Tray Chill Room
Case Vegetable
GPPS
HIPS.(Cool White)
Al
HIPS.
HIPS.
WSF19.5A-L,CHANGHENG
E17 No-Safety
E14 Safety
E17 110~127V/60Hz
E17 220~240V/50~60Hz
E14 110~127V/60Hz
E14 220~240V/50~60Hz
HDPE
PP(Cool White)
250V/ 0.5A , 125V/1.5A
PP(Cool White)
GPPS.
GPPS.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
100-127V/60Hz
Export
N-Safety
RA-
18
Export
Safety
Domestic
220-240V/50~60Hz
Cover Evap
3
Knob Defrost
9
11
12
Export
Safety
Export
N-Safety
RA-
20
RA-
18
RA-
20
RA-
18
RA-
20
RA-
18
RA-
20
RA-
18
RA-
20
1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1
1 1 1 1
1 1 1 1 1 1 1 1
Option Shelf
A
B
C
DA67-00992A Shelf Ref. GPPS.
DA67-00992A Shelf Ref. GPPS.
DA67-00992A Shelf Ref. GPPS.
Glass
PP(Cool White)
Shelf Glass
Trim Glass Front
DA67-01084A
DA64-01089A
Shelf Wire
Trim Shelf Wire
MSWR10+PP(Cool White)
PP(Cool White)
3 3 3 3 3 3 3 3 3 3
2 2 2 2 2 2 2 2
2 2 2 2 2 2 2 2
1 1 1 1 1 1 1 1
2 2 2 2 2 2 2 2
2 2 2 2 2 2 2 2
1 1 1 1 1 1 1 1
DA67-01085A Shelf Glass Ass'y
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH
10 Replacement parts list
10-3 Ass'y-cabinet parts
10-7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
21-1
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH
10 Replacement parts list
10-3-1 Ass'y-cabinet parts List
10-8
Code No No Description Specification
110~115V
/60Hz
S
S
S
W
M
G
C
G
N
B
T
T
127V
/60Hz
220V
/60Hz
220V
/50~60Hz
220~240V
/50Hz
RA18FH/RA18VH/RA20FH/RA20VH
S
S
S
W
M
G
C
G
N
B
T
T
S
S
S
W
M
G
C
G
N
B
T
T
S
S
S
W
M
G
C
G
N
B
T
T
S
S
S
W
M
G
C
G
N
B
T
T
DA61-01497B
6011-001546
DA67-40311B
DA39-10156A
DA39-10139B
DA39-00165A
DA39-10138A
DA39-10172A
DA39-10105B
DA39-10157A
DA35-10016A
DA39-10102A
DA67-10450A
2501-001301
DA60-20008C
DA59-00309A
DA63-01962A
DA35-00056A
DA35-00057A
DA63-01961A
DA65-00033A
1
2
3
4
5
7
8
9
10
11
12
13
14
Hinge Upper
Bolt-Hex.
Tray Drain Water
Power Cord
Power Cord
Power Cord
Power Cord
Power Cord
Power Cord
Power Cord
Power Cord
Power Cord
Case Junction
Running Capacitor
Bolt Hex
Compressor
Grommet Comp.
Protector O/L
Relay Starting
Cover Relay
Clamp Cover Relay
SCP1
M5xL16xP0.8
PP. Natural
UCP2
BF3
BF3
EP2
EP2
SPT3
CP2
AP3
BP3
SBHG1,T0.8
3.5mF,360VAC
M6,L35,ZPC(WHT)
C-BF75L5Z ,SANYO
NR,H21.5,BLK,SANYO
4TM174RHBYY-53
PTH7M220MD2,300V/7A
Noryl,Black
SK5,SANYO,ZPC
DA73-30111A Dryer-Hex C1220T,OD18.85,ID4.76,L100,2SI
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1
4 4 4 4 4 4
4 4 4 4 4 4
1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1
2501-000413
DA60-20008A
DA59-00100A
DA63-40234C
DA34-10003U
DA35-10003M
DA63-10722A
DA65-20113A
7
8
9
10
11
12
13
14
Running Capacitor
Bolt Hex
Compressor
Grommet Comp.
Protector O/L
Relay Starting
Cover Relay
Clamp Cover Relay
8mF,250 VAC
M6,L35,ZPC(YEL)
SD137C-L1Z2,SAMSUNG
NBR,SAMSUNG
4TM317RH BYY-53
J531Q32E6R8M1602
PP,V451
SK5,SAMSUNG
1 1 1 1 1 1
4 4 4 4 4 4
4 4 4 4 4 4
1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1
DA59-00099A
DA63-40234C
DA34-10004C
DA35-10003D
DA63-10722A
DA65-20113A
9
10
11
12
13
14
Compressor
Grommet Comp.
Protector O/L
Relay Starting
Cover Relay
Clamp Cover Relay
SD137H-L1Z2,SAMSUNG
NBR,SAMSUNG
4TM189SFBYY-53
J531Q35E330M385-2
PP,V451
SK5,SAMSUNG
4 4 4 4 4 4
1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1
DA60-20008A 8 Bolt Hex M6,L35,ZPC(YEL) 4 4 4 4 4 4
2501-001298
DA60-20008C
DA59-00318A
7
8
9
Running Capacitor
Bolt Hex
Compressor
4mF,440VAC
M6,L35,ZPC(WHT)
AZA1335YK-4R,KK-COMP.
1 1 1 1 1 1
4 4 4 4 4 4
1 1 1 1 1 1
DA61-00170D 6 Case Junction PP UL94-VO ,SAFETY 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
DA61-00170B Case Junction PP-SCRAP ,NO-SAFETY 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH
10 Replacement parts list
10-3-1 Ass'y-cabinet parts List
10-9
Code No No Description Specification
110~115V
/60Hz
S
S
S
W
M
G
C
G
N
B
T
T
127V
/60Hz
220V
/60Hz
220V
/50~60Hz
230~240V
/50Hz
RA18FH/RA18VH/RA20FH/RA20VH
S
S
S
W
M
G
C
G
N
B
T
T
S
S
S
W
M
G
C
G
N
B
T
T
S
S
S
W
M
G
C
G
N
B
T
T
S
S
S
W
M
G
C
G
N
B
T
T
DA60-10124B 17 Screw-Tap Tite M6,L12,ZPC2-Y(NO-STAND ONLY)
DA61-01498A
6003-000339
DA61-01073B
18
19
20
Hinge Low
Screw-Tap Tite
Foot Front,R
SCP1
M6,L16,ZPC2-Y
PP(NO-STAND ONLY)
DA60-00094A
21
Fastener Washer PP(NO-STAND ONLY)
DA69-00485A
DA60-10124B
22
23
Stand Table Ass'y
Screw-Tap Tite
PP,SS
M6,L12,ZPC2-Y
2 2 2 2 2 2
1 1 1 1 1 1
2 2 2 2 2 2
1 1
6 6 6 6 6 6
DA69-00485B Stand Table Ass'y PP,SW
DA69-00485C Stand Table Ass'y PP,MG
DA69-00485D Stand Table Ass'y PP,CG
DA69-00485E Stand Table Ass'y PP,NB
1
1
1
1
DA61-01073C Foot Front,L PP(NO-STAND ONLY)
21-1
2 2 2 2 2 2
1 1 1 1 1 1
2 2 2 2 2 2
1
6 6 6 6 6 6
1
1
1
1
2 2 2 2 2 2
1 1 1 1 1 1
2 2 2 2 2 2
1
6 6 6 6 6 6
1
1
1
1
2 2 2 2 2 2
1 1 1 1 1 1
2 2 2 2 2 2
1
6 6 6 6 6 6
1
1
1
1
2 2 2 2 2 2
1 1 1 1 1 1
2 2 2 2 2 2
1
6 6 6 6 6 6
1
1
1
1
DA39-20412C
DA61-01499A 16
Wire Harness Relay
Chasiss-Comp
With Capacitor
SBHG1(NO-STAND ONLY)
DA39-20394E Wire Harness Relay Without Capacitor
1 1 1 1 1 1
1 1 1 1 1 1
15
1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
DA35-00066A
DA35-00064A
DA63-01001A
DA65-20122A
11
12
13
14
Protector O/L
Relay Starting
Cover Relay
Clamp Cover Relay
4TM412LFBYY-53
J531Q31C3R9M1602
Poly Carbonate
Stanless Wire Spring
1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1
DA59-00317A
DA63-01962A
DA35-00065A
DA35-00063A
DA63-01961A
DA65-00033A
9
10
11
12
13
14
Compressor
Grommet Comp.
Protector O/L
Relay Starting
Cover Relay
Clamp Cover Relay
C-BF 75L6Z,SANYO
NR,H21.5,BLK,SANYO
4TM232RHBYY-53
PTH7M330MC1
PP,V451
SK5,SANYO
4 4 4 4 4 4
1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1
DA60-20008C 8 Bolt Hex M6,L35,ZPC(WHT) 4 4 4 4 4 4
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
DA63-40269A 10 Grommet Comp. NBR , KK-COMP. 4 4 4 4 4 4 4 4 4 4 4 4
1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH
10 Replacement parts list
10-4 Ass'y-Water Dispenser Parts
10-10
1
3
4-1
5-1
6
7
2
Step for take off dispenser
1. Pull cover-dispenser and remove it.
2. Take off two screws at base dispenser.
3. Take off cover hose dispenser from tank water .
5.Pull ass'y cock dispenser from base dispenser.
4.Take off hose dispenser from tank water and ass'y cock dispenser.
4-2
5-2
5-3
REV.01/AUG.2004
RA18FH/RA18VH/RA20FH/RA20VH
10 Replacement parts list
10-4-1 Ass'y-water dispenser parts List
10-11
Code No No Description Specification
1
RA18
SS MG CG TT
RA20
SW NB SS MG CG TT SW NB
DA62-00691A
6002-000470
DA66-00256A
DA63-01879A
DA64-01124D
DA67-00991A
DA63-01873A
DA67-00990A
DA67-00993A
DA63-01881A
Assy-Cock Disp.
Screw-Tapping
Lever-Dispenser
Cover-Dispenser
Trim Cover Disp.
Cap Water Tank
Cover Tank Water
Tank Water
Hose Disp.
Cover Hose Disp.
ABS,TS1-PJT
M4xL10 ZPC,SCRCH18A
ABS,Cr-Coating
ABS,Silver Spray
ABS,SS
ABS,SW
ABS,MG
ABS,CG
MIPS,COOL WHITE
MIPS,COOL WHITE
GPPS
SILICONE(FOOD GRADE)
PP,COOL WHITE
DA64-01124A Trim Cover Disp.
DA64-01124B Trim Cover Disp.
DA64-01124C Trim Cover Disp.
DA64-01124E Trim Cover Disp. ABS,NB
1 1 1 1 1 1 1 1 1 1 1 1
2 2 2 2 2 2 2 2 2 2 2 2
1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1
1
1
1
1
1
1
1
1
1
1
1
1
2
3
4-1
6
7
Cover-Disp Ass'y
4
4-2
Tank Water Ass'y 5
5-1
5-2
5-3
ABS,SS
ABS,SW
ABS,MG
ABS,CG
ABS,NB
Cover-Disp Ass'y
Cover-Disp Ass'y
Cover-Disp Ass'y
Cover-Disp Ass'y
DA67-01008A
DA63-02180A
DA63-02180B
DA63-02180D
DA63-02180E
DA63-02180C
REV.01/AUG.2004
Thai Samsung Electronics Co., Ltd.
Rev.00/Feb 2004
Printed in Thailand.
E LE CTR ONICS
Rev.01/Aug 2004 : Cyclopentane-Pjt.
REV.01/AUG.2004