Sie sind auf Seite 1von 50

Broadband Powerline Communication

ICT for Smart Metering and Smart Grids


Private and Confidential PPC 2012, www.ppc-ag.com 2
About PPC
Customers, Projects and Partners

About PPC
Broadband Powerline (BPL) for low and
medium voltage networks
IP-based, scalable & real-time solution for
Smart Grids & Smart Metering
Standards based
Meter vendor independent
First company to apply for German BSI
certification

Germany International Partners
Customers & partners
Power networks supplying more than
1 million people already equipped
Private and Confidential PPC 2012, www.ppc-ag.com 3
Vendor independent ICT infrastructure
PPC bridges the gap between the physical network and the core IT/service

For Smart Metering and Smart Grid Applications
Operating Data
Smart Metering
Automation/Control
Communications Network
D
a
t
a

A
c
q
u
i
s
i
t
i
o
n

&

P
r
o
c
e
s
s
i
n
g


S
y
s
t
e
m

I
n
t
e
r
f
a
c
e
s

Services
Billing
Trading
Operations
LV & MV Network
*
Core IT/Services
Smart Grid
PPC Focus area
Private and Confidential PPC 2012, www.ppc-ag.com 4
Open Smart Metering Infrastructure
Meter Manufacturers integrated by today
Private and Confidential PPC 2012, www.ppc-ag.com 5
Open Smart Home Infrastructure
eHome Manufacturers integrated by today
GEO
Private and Confidential PPC 2012, www.ppc-ag.com 6
Smart Grid ready by PPC
IP everywhere over power lines
*MV = Medium Voltage and LV = Low Voltage
Real-time platform for data capture, operations, reporting and customer interactions

Private and Confidential PPC 2012, www.ppc-ag.com 7
Products



Low Voltage Products Medium Voltage Products Software Products
Gateway/Repeater/Head-end
Connectivity Kits
OEM Meter Solutions Medium Voltage Coupler
Connectivity Kits
Gateway
Network Management System
Data Collection System
Private and Confidential PPC 2012, www.ppc-ag.com 8
Definition PLC - BPL
08.08.2003
8
Technology Age Frequency Power Bandwidth
Ripple control 110 years Hz < 100 kW bps
PLC 15 years kHz < 2,5 W kbps
BPL 5 years MHz < 88 mW Mbps
Private and Confidential PPC 2012, www.ppc-ag.com 9
PLC vs. BPL
Technology Basics
Narrow Band Powerline
(PLC)
Frequency in Mhz 1 30 0,2 0,01
Broadband Powerline
(BPL)
T
r
a
n
s
m
i
s
s
i
o
n

L
e
v
e
l

IEEE 1901
Private and Confidential PPC 2012, www.ppc-ag.com 10
BPL system in detail
Automatic adoption of data channels
Private and Confidential PPC 2012, www.ppc-ag.com 11
BPL system in detail
Automatic adoption of data channels
Private and Confidential PPC 2012, www.ppc-ag.com 12
12
The Aranuka BPL - System
Setup and Operation
Private and Confidential PPC 2012, www.ppc-ag.com 13
13
The Aranuka BPL - System
Setup and Operation
Private and Confidential PPC 2012, www.ppc-ag.com 14
14
The Aranuka BPL - System
Setup and Operation
Ready for meshed and star architecture
Private and Confidential PPC 2012, www.ppc-ag.com 15
15
The Aranuka BPL - System
Setup and Operation
Private and Confidential PPC 2012, www.ppc-ag.com 16
16
The Aranuka BPL - System
Setup and Operation
Private and Confidential PPC 2012, www.ppc-ag.com 17
The Aranuka BPL - System
Setup and Operation
Private and Confidential PPC 2012, www.ppc-ag.com 18
The Aranuka BPL - System
Setup and Operation
Private and Confidential PPC 2012, www.ppc-ag.com 19
System is permanently optimising the meshed
structure. Shown are just links which are currently
in use
Screen-Shot Netzwerkmanagement System NMS
Private and Confidential PPC 2012, www.ppc-ag.com 20
BPL-Gateway LGW200


One BPL-Gateway connects all applications
Smart Metering
Renewables and/or Micro CHPs
Charging stations for EVs
e-Home services

Home-IP connection to the applications
Private and Confidential PPC 2012, www.ppc-ag.com 21
LV-Networks

One Gateway per location
Connects all meters over standard
interfaces
Installation of meters from different
manufacturers in one building
Interfaces:
Ethernet
Wireless M-Bus
RS 485
Zigbee

Interface extensions:
Current Loop (CS)
Wired MBUS (EN13757-3)

Interfaces to the Gateways
Private and Confidential PPC 2012, www.ppc-ag.com 22
Installation Example
LV-Network
Private and Confidential PPC 2012, www.ppc-ag.com 23
LV-Network
Installation example
Meter room with meter cabinet:
BPL Gateway with wirelesM-Bus wireless
Piggy-back connection with integrated fuse
27.07.2012
Copyright PPC-AG 2011
Private and Confidential PPC 2012, www.ppc-ag.com 24
Piercing technology Piggy back technology
LV-Network
Transformer station Installation of LH200

Installation examples
Private and Confidential PPC 2012, www.ppc-ag.com 25
Piercing technology
LV-Network
Transformer station (II) Installation of LH200

Installation example
Private and Confidential PPC 2012, www.ppc-ag.com 26
Piggy back technology
LV-Network
Street cabinet/ distribution box - Installation of LR200

Installation examples
Private and Confidential PPC 2012, www.ppc-ag.com 27
Piggy back technology Piercing technology
LV-Network
Street cabinet/ distribution box (II) - Installation of LR200

Installation examples
Private and Confidential PPC 2012, www.ppc-ag.com 28
Piggy back technology Piercing technology
LV-Network
Main entrance box - Installation of LGW200

Installation examples
Private and Confidential PPC 2012, www.ppc-ag.com 29
Piggy back technology Piercing technology
LV-Network
Main entrance box (II) - Installation of LGW200

Installation examples
Private and Confidential PPC 2012, www.ppc-ag.com 30
Piggy back technology Dual phase connection kit
LV-Network
Meter cabinet - Installation of LGW200

Installation examples
Private and Confidential PPC 2012, www.ppc-ag.com 31
Dual phase connection kit
LV-Network
Meter cabinet (II) - Installation of LGW200

Installation examples
Private and Confidential PPC 2012, www.ppc-ag.com 32
Piercing technology Radio-Backbone LH200
LV-Network
Overhead wires - Installation of LR200 & LH200


Installation examples
Private and Confidential PPC 2012, www.ppc-ag.com 33
Piercing technology
LV-Network
Overhead wires (II) - Installation of LR200
Installation examples
Private and Confidential PPC 2012, www.ppc-ag.com 34
Piercing technology
LV-Network
Overhead wires (III) - Installation of LR200

Installation examples
Private and Confidential PPC 2012, www.ppc-ag.com 35
Coupling capacitor
LV-Network
Coupling capacitor

Installation examples
Private and Confidential PPC 2012, www.ppc-ag.com 36
BPL over MV cables
Structure
MV Cable
BPL MV24CC BPL MV24CC
MV200 MV200
MV Cable
BPL MV24CC BPL MV24CC
MV200 MV200
MV Cable
BPL MV24CC BPL MV24CC
MV200 MV200
MV Cable
BPL MV24CC BPL MV24CC
MV200 MV200
MV BPL Modem
MV200
MV BPL Coupler
BPL12CC
MV BPL Coupler
BPL12CC
MV BPL Modem
MV200
Copyright PPC-AG 2011
Private and Confidential PPC 2012, www.ppc-ag.com 37
37
Installation Example
Private and Confidential PPC 2012, www.ppc-ag.com 38
Installation Example
Private and Confidential PPC 2012, www.ppc-ag.com 39
MV-Network
Gas insulated switchgears
Installation Example
Copyright PPC-AG 2011
Private and Confidential PPC 2012, www.ppc-ag.com 40
MV-Network
Gas insulated switchgears
Installation Example
Copyright PPC-AG 2011
Private and Confidential PPC 2012, www.ppc-ag.com 41
MV-Network
Installation examples
Copyright PPC-AG 2011
Private and Confidential PPC 2012, www.ppc-ag.com 42
MV-Network
Installation examples
Copyright PPC-AG 2011
Private and Confidential PPC 2012, www.ppc-ag.com 43
The Aranuka BPL-System

The Aranuka Headend (LH200) will be installed in substations (transformers)
or others junctions of the low-voltage system and connected with its
Ethernet Port to the backbone network. (UMTS, Wireless, Wimax fiber optics
or xDSL).
Aranuka Headend (LH200)
Private and Confidential PPC 2012, www.ppc-ag.com 44
The Aranuka BPL-System

In order to cover larger distances Aranuka Repeater (LR200) are installed in
distribution cabinets or connection boxes.
The LR200 establishes links to all of its neighbouring devices and therefore
forms a meshed structure which ensures reliability and redundancy
It receives the data from the previous device and passes it on to the following
along the line
Aranuka Repeater (LR200)
Private and Confidential PPC 2012, www.ppc-ag.com 45
The Aranuka BPL-System
In the meter room/roof an Aranuka Gateway (LGW200) is connecting meters
via wireless M-bus interfaces
One LGW200 can serve several meters, therefore only one BPL Gateway per
house and/or meter room is necessary
Aranuka Gateway (LGW200)
Private and Confidential PPC 2012, www.ppc-ag.com 46
The Aranuka BPL-System
The Metering Gateway LGW200DR in
DIN-rail housing has been
specifically developed to be fitted
into the meter cabinet
It has all the interfaces of the
LGW200 and the same
functionalities
Additionly in provides RS485

Aranuka Gateway in DIN-rail housing (LGW200DR)
Private and Confidential PPC 2012, www.ppc-ag.com 47
Technical data
Rated voltage U
N
230-240V/400V AC
Rated frequency 50Hz
Rated current for fuse I
N
1A
Fuse breaking capacity 50kA
Rated impulse voltage U
imp
6kV
Over voltage category IV
Installation condition Sheltered
LV-Network
Connection Kit (CK130)
Connection Kit with system connector (S200) for two-phase connection of BPL Modems
in substations and street cabinets, with two clamping brackets (appr. 45mm long),
integrated fuse to connect on NH-fuses and one open wire to connect to PEN
Piggy back connection
Private and Confidential PPC 2012, www.ppc-ag.com 48
LV-Network
Connection Kit (CK200)
Connection Kit with system connector (S200) for two-phase connection of BPL Modems
in substations and street cabinets, with two piercing-connections, integrated fuse,
piercing elements and one open wire to connect to PEN
Piercing connection
Technical data
Rated voltage U
N
230-240V/400V AC
Rated frequency 50Hz
Rated current for fuse I
N
1A
Fuse breaking capacity 50kA
Rated impulse voltage U
imp
6kV
Over voltage category IV
Installation condition Sheltered
Private and Confidential PPC 2012, www.ppc-ag.com 49
LV-Network
Connection Kit (CK250)
Connection Kit with system connector (S200) for two-phase connection of BPL Modems
in the Cat IV low voltage network, integrated fuse and bus clamp connect to PEN
Dual phase connection kit
Technical data
Rated voltage U
N
230-240V/400V AC
Rated frequency 50Hz
Rated current for fuse I
N
1A
Fuse breaking capacity 50kA
Rated impulse voltage U
imp
6kV
Over voltage category IV
Installation condition Sheltered
Private and Confidential PPC 2012, www.ppc-ag.com 50
Thank you!
Power Plus Communications AG Am Exerzierplatz 2 68167 Mannheim Germany www.ppc-ag.com