Beruflich Dokumente
Kultur Dokumente
Fittings Dimensions
for Bondstrand Series 2000, 4000, 5000,
and 7000 fiberglass piping systems
in 1 through 16-inch sizes
Table of contents
ISO-9001
CERTIFICATED FIRM
Introduction.......................................................................02
Manufacturing methods ...................................................02
Assembly instructions ......................................................02
90 elbows.........................................................................03
90 flanged elbows............................................................03
90 combination elbows ...................................................04
45 elbows.........................................................................04
45 flanged elbows............................................................05
45 combination elbows ...................................................05
221/2 elbows .....................................................................05
Tees ...................................................................................06
Reducing tees ...................................................................06
Flanged tees......................................................................07
Combination tees..............................................................07
Flanged reducing tees.......................................................08
45 laterals.........................................................................08
45 flanged laterals............................................................09
Tapered body reducers .....................................................09
Flanged tapered body reducers ........................................10
Combination reducers (flanged small end)........................10
Combination reducers (flanged large end) ........................11
Pipe nipples.......................................................................11
Couplings and end caps ...................................................12
Crosses .............................................................................12
Flanges..............................................................................13
Reducing flanges ..............................................................13
Blind flanges......................................................................14
Heavy-duty flanges ...........................................................14
Orifice flanges ...................................................................15
Maintenance couplings.....................................................15
Adapters (threaded and Victaulic) .....................................16
Molded plugs ....................................................................16
Molded reducer bushings .................................................16
Blank saddles....................................................................17
Reducing saddles (bushed outlets)...................................17
Reducing saddles (flanged and Quick-Lock outlets) .......18
Pressure ratings for fittings ..........................................19, 20
Important note...................................................................20
FP 282B (9/07)
90 combination elbows
L1
t
L2
D
Ds
Nom
Pipe
Size
in. mm
1
112
2
25
40
50
80
4 100
6 150
8 200
10 250
12 300
14 350
16 400
Radius
Type
l/r
l/r
s/r
l/r
s/r
l/r
s/r
l/r
s/r
l/r
s/r
l/r
s/r
l/r
s/r
l/r
l/r
l/r
Laying
Length
(L1)
in. mm
5.00
6.00
4.50
6.50
5.50
7.75
6.50
9.00
8.00
11.50
9.00
14.00
11.00
16.50
12.00
19.00
21.50
24.00
Flange Thickness
At Face
At Hub
(t)
(D)
in. mm
in. mm
127
152
114
165
140
197
165
229
203
292
229
356
279
419
305
483
546
610
1.13**
1.38**
1.00
1.00
1.13
1.13
1.25
1.25
1.75
1.75
2.00
2.00
2.00
2.00
2.13
2.13
2.88**
3.25**
45 elbows
1.13 29
1.38 35
2.00 51
2.00 51
2.00 51
2.00 51
2.00 51
2.00 51
2.38 60
2.38 60
2.63 67
2.63 67
2.88 73
2.88 73
3.13 80
3.13 80
3.75 95
4.25 108
3.62
4.44
6.56
8.56
7.56
9.81
8.56
11.06
10.50
14.00
11.75
16.75
14.00
19.50
15.25
22.25
17.62
19.62
92
113
167
217
192
249
217
281
267
356
298
425
356
495
387
565
448
498
Laying
Length
(L2)
in. mm
2.56
3.19
4.75
6.75
5.75
8.00
6.75
9.25
8.25
11.75
9.25
14.25
11.25
16.75
12.25
19.25
14.12
15.62
Socket
Depth
(Ds)
in. mm
65
81
121
171
146
203
171
235
210
298
235
362
286
425
311
489
359
397
1.06
1.25
1.81
1.81
1.81
1.81
1.81
1.81
2.25
2.25
2.50
2.50
2.75
2.75
3.00
3.00
3.50
4.00
Approx Wt
Flange Type
(m)
(f/w)
lb. kg
lb. kg
27
32
46
46
46
46
46
46
57
57
64
64
70
70
76
76
89
102
4
4
6
6
8
10
16
20
26
32
38
45
61
70
1.8
1.8
2.7
2.7
3.6
4.5
7.3
9.1
11.8
14.5
17.2
20.4
27.7
31.8
2
3
3
4
5
6
8
10
14
18
23
31
34
45
61
70
85
104
0.9
1.4
1.4
1.8
2.3
2.7
3.6
4.5
6.4
8.2
10.4
14.1
15.4
20.4
27.7
31.8
38.6
47.2
Fittings are filament wound unless otherwise designated. Fittings marked with
an asterisk (*) are molded.
Nom
Pipe
Size
in. mm
B
L
Ds
29
35
25
25
29
29
32
32
44
44
51
51
51
51
54
54
73
83
Overall
Length
(B)
in. mm
01
0112
02
25
40
50
03
80
04
100
06
150
08
10
12
14
16
200
250
300
350
400
Laying
Length
(L)
in. mm
0.88
1.12
1.38
1.38*
2.00
1.62*
2.50
2.42*
3.75
3.31*
5.00
6.25
7.50
4.69
5.38
22
28
35
35
51
41
64
61
95
84
127
159
191
119
137
Overall
Length
(B)
in. mm
1.94
2.37
3.20
3.20
3.82
3.43
4.32
4.23
6.00
5.56
7.50
9.00
10.50
8.19
9.38
49
60
81
81
97
87
110
107
152
141
191
229
267
208
238
Socket
Depth
(Ds)
in. mm
Approx
Wt
1.06
1.25
1.82
1.82
1.82
1.82
1.82
1.82
2.25
2.25
2.50
2.75
3.00
3.50
4.00
1
1
1
1
2
2
3
3
5
8
9
16
26
38
45
27
32
46
46
46
46
46
46
57
57
64
70
76
89
102
lb. kg
0.5
0.5
0.5
0.5
0.9
0.9
1.4
1.4
2.3
3.6
4.1
7.3
11.8
17.2
20.4
45 flanged elbows
Flanges are filament wound unless otherwise designated. Fittings marked with
an asterisk (*) have molded flanges. Laying lengths meet ANSI criteria.
Fittings with double asterisk (**) do not meet ANSI laying length.
Nom
Pipe
Size
in. mm
02
03
04
06
08
10
12
14
16
L
t
45 combination elbows
2.50
3.00
4.00
5.00
5.50
6.50
7.50
12.25**
13.94**
Flange Thickness
At Face
At Hub
(t)
(D)
in. mm
in. mm
64
76
102
127
140
165
191
311
354
1.00
1.13
1.25
1.75
2.00
2.00
2.13
2.81
3.25
25
29
32
44
51
51
54
71
83
2.00 51
2.00 51
2.00 51
2.38 60
2.63 67
2.88 73
3.13 80
3.81 97
4.25 108
Approx
Wt
(m)
lb. kg
5
7
10
21
32
50
76
(f/w)
lb. kg
2.3
3.2
4.5
9.5
14.5
22.7
34.5
.
04
06
10
17
29
47
70
59
77
1.8
2.7
4.5
7.7
13.2
21.3
31.8
26.8
34.9
L1
50
80
100
150
200
250
300
350
400
Laying
Length
(L)
in. mm
L2
B
Ds
Nom
Pipe
Size
in. mm
*2
*3
*4
*6
*8
10
12
14
16
50
80
100
150
200
250
300
350
400
Laying
Length
(L1)
in. mm
2.50
3.00
4.00
5.00
5.50
6.50
7.50
12.25**
13.94**
64
76
102
127
140
165
191
311
354
221/2 elbows
Flange Thickness
At Face
At Hub
(t)
(D)
in. mm
in. mm
1.00
1.13
1.25
1.75
2.00
2.00
2.13
2.81
3.25
25
29
32
44
51
51
54
71
83
2.00
2.00
2.00
2.38
2.63
2.88
3.13
3.81
4.25
51
51
51
60
67
73
80
97
108
Overall
Length
(B)
in. mm
4.56
5.06
6.06
7.50
8.25
9.50
10.75
8.18
9.38
116
129
154
191
210
241
273
208
238
Laying
Length
(L2)
in. mm
2.75
3.25
4.25
5.25
5.75
6.75
7.75
4.69
5.38
70
83
108
133
146
171
197
119
137
Socket
Depth
(Ds)
in. mm
1.82 46
1.82 46
1.82 46
2.25 57
2.50 64
2.75 70
3.00 76
3.50 89
4.00 102
Approx Wt
Flange Type
(m)
(f/w)
lb. kg
lb. kg
3
5
7
15
23
38
55
63
69
1.4
2.3
3.2
6.8
10.4
17.2
24.9
28.6
31.3
*3
*4
7
13
23
38
54
60
66
1.4
1.8
3.2
5.9
10.4
17.2
24.5
27.2
29.9
Fittings feature filament-wound Quick-Lock bell ends. Elbows with angles such
as 111/4, 30, 60 and 75 and other special angles are available. Consult your
Ameron representative.
B
L
Ds
Nom
Pipe
Size
in. mm
1
112
2
3
4
6
8
10
12
14
16
25
40
50
80
100
150
200
250
300
350
400
Laying
Length
(L)
in. mm
0.38
0.38
0.50
0.81
1.12
1.69
2.25
2.62
3.00
3.25
3.50
10
10
13
21
28
43
57
67
76
83
89
Overall
Length
(B)
in. mm
1.44
1.63
2.31
2.62
2.94
3.94
4.75
5.38
6.00
6.75
7.50
37
41
59
67
75
100
121
137
152
171
191
Socket
Depth
(Ds)
in. mm
1.06
1.25
1.82
1.82
1.82
2.25
2.50
2.75
3.00
3.50
4.00
27
32
46
46
46
57
64
70
76
89
102
Approx
Wt
lb. kg
0.3
0.5
0.7
1.3
2.0
4.0
7.0
13.0
16.0
26.0
30.0
0.1
0.2
0.3
0.6
0.9
1.8
3.2
5.9
7.3
11.8
13.6
Flanged tees
Flanges are filament wound unless otherwise noted. Molded flanges available
in 2- through 12-inch sizes. Fittings noted with an asterisk (*) do not meet ANSI
laying lengths. Flange thickness with double asterisk (**) represents molded
flange dimension.
Nom
Pipe
Size
in. mm
Combination tees
1
112
2
3
4
25
40
50
80
100
6
8
10
12
14
16
150
200
250
300
350
400
Laying
Length
(L)
in. mm
3.50
4.00
4.50
5.50
6.50
6.50
8.00
9.00
11.00
12.00
18.00*
20.00*
89
102
114
140 .
165
165
203
229
279
305
457
508
Flange Thickness
At Face
At Hub
(t)
(D)
in. mm
in. mm
1.13
1.38
1.00
1.13
1.25
1.56**
1.75
2.00
2.00
2.13
2.81
3.25
29
35
25
29
32
40
44
51
51
54
71
83
1.13
1.38
2.00
2.00
2.00
2.38
2.63
2.88
3.13
3.81
4.25
Approx
Wt
lb. kg
29
35
51
51
51
60
67
73
80
97
108
2
3
7
11
17
17
32
47
70
114
220
280
0.9
1.4
3.2
5.0
7.7
7.7
14.5
21.3
31.8
51.7
99.8
127.0
Flanges are filament wound unless otherwise noted. Molded flanges are
available in 2- through 12-inch sizes. Any combination of flanged or QuickLock ends is available. Fittings noted with an asterisk (*) do not match ANSI
laying length dimensions. Quick-Lock bell ends in 14- and 16-inch sizes are
integrally wound.
L1
t
L2
L1
D
QL x FLG x QL
QL x FLG x FLG
Nom
Pipe
Size
in. mm
1
1 1 2
2
3
4
6
8
10
12
14
16
25
40
50
80
100
150
200
250
300
350
400
Laying
Length
(L1)
in. mm
3.50
4.07
4.50
5.50
6.50
8.00
9.00
11.00
12.00
18.00*
20.00*
89
103
114
140
165
203
229
279
305
457
508
Laying
Length
(L2)
in. mm
1.06
1.19
4.75
5.75
6.75
8.25
9.25
11.25
12.25
10.50
11.50
27
30
121
146
171
210
235
286
311
267
292
FLG x FLG x QL
QL x QL x FLG
Flange Thickness
At Face
At Hub
(t)
(D)
in. mm
in. mm
1.13
1.38
1.00
1.13
1.25
1.75
2.00
2.00
2.13
2.81
3.25
29
35
25
29
32
44
51
51
54
71
83
1.13
1.38
2.00
2.00
2.00
2.38
2.63
2.88
3.13
3.81
4.25
29
35
51
51
51
60
67
73
80
97
108
Approx Wt
1 cplg
2 flgs
lb. kg
3
4
6
10
14
28
41
61
98
130
145
1.4
1.8
2.7
4.5
6.4
12.7
18.6
27.7
44.5
59.0
65.8
2 cplg
1 flg
lb. kg
3
4
5
8
12
24
35
52
82
120
130
1.4
1.8
2.3
3.6
5.4
10.9
15.9
23.6
37.2
54.4
59.0
45 flanged laterals
Flanges are filament wound and meet ANSI B16.5 Cl 150 requirements.
Nom
Pipe
Size
in. mm
L2
2
3
4
6
8
10
12
14
16
t
L2
L1
Laying
Length
(L1)
in. mm
50
80
100
150
200
250
300
350
400
6.44
6.94
6.94
8.25
9.76
10.75
11.75
13.06
14.00
164
176
176
210
248
273
298
332
356
Laying
Length
(L2)
in. mm
11.94
13.94
15.94
19.25
22.75
26.25
30.75
32.00
33.00
303
354
405
489
578
667
781
813
838
Flange Thickness
At Face
At Hub
(t)
(D)
in. mm
in. mm
1.00
1.13
1.25
1.75
2.00
2.00
2.13
2.81
3.25
25
29
32
44
51
51
54
71
83
2.00
2.00
2.00
2.38
2.63
2.88
3.13
3.81
4.25
Approx
Wt
lb. kg
51
51
51
60
67
73
80
97
108
9
4.1
14
6.4
20
9.1
34 15.4
57 25.9
89 40.4
136 61.7
201 91.2
269 122.0
Nom
Pipe
Size
in. mm
1 2 x1
2x1
2x112
3x2
4x2
4x3
6x3
6x4
8x4
8x6
10x6
10x8
12x8
12x10
14x10
14x12
16x12
16x14
1
40x25
50x25
20x40
80x50
100x50
100x80
150x80
150x100
200x100
200x150
250x150
250x200
300x200
300x250
350x250
350x300
400x300
400x350
Overall
Length
(B)
in. mm
3.56
5.38
4.32
5.75
6.62
6.50
7.88
7.75
9.75
8.63
9.62
9.37
11.38
11.12
13.50
13.50
13.50
13.50
90
137
110
146
168
165
200
197
248
219
244
238
289
282
343
343
343
343
Laying
Length
(L)
in. mm
1.31
2.50
1.25
2.12
3.00
2.88
3.81
3.69
5.44
3.88
4.62
4.12
5.88
5.38
7.25
7.00
6.50
6.00
33
64
32
54
76
73
97
94
138
99
117
105
149
137
184
178
165
152
Socket
Depth
(Ds1)
in. mm
1.06
1.06
1.25
1.82
1.82
1.82
1.82
1.82
1.82
2.25
2.25
2.50
2.50
2.75
2.75
3.00
3.00
3.50
27
27
32
46
46
46
46
46
46
57
57
64
64
70
70
76
76
89
Socket
Depth
(Ds2)
in. mm
1.25
1.82
1.82
1.82
1.82
1.82
2.25
2.25
2.50
2.50
2.75
2.75
3.00
3.00
3.50
3.50
4.00
4.00
32
46
46
46
46
46
57
57
64
64
70
70
76
76
89
89
102
102
Approx
Wt
lb. kg
0.4
0.6
1.0
1.4
2.0
2.0
4.0
4.0
7.0
7.0
9.0
8.0
14.0
13.0
36 .0
37.0
54.0
57.0
0.2
0.3
0.5
0.6
0.9
0.9
1.8
1.8
3.2
3.2
4.1
3.6
6.4
5.9
16.3
16.8
24.5
25.9
Flanges are filament wound. Flanges in 2-, 3- and 4-inch sizes are available only
in heavy-duty (hubless) configuration. Molded flanges available in
2- through 12-inch sizes. Fittings with asterisk (*) meet ANSI laying lengths.
L
t1
t2
D2
D1
Nom
Pipe
Size
in. mm
1 2x1
2x1
2x11 2
3x2*
4x2*
4x3*
6x3*
6x4*
8x4*
8x6*
10x6*
10x8*
12x8*
12x10*
14x10*
14x12*
16x12*
16x14*
Laying
Length
(L)
in. mm
40x25
50x25
20x40
80x50
100x50
100x80
150x80
150x100
200x100
200x150
250x150
250x200
300x200
300x250
350x250
350x300
400x300
400x350
6.50
8.75
8.00
6.00
7.00
7.00
9.00
9.00
11.00
11.00
12.00
12.00
14.00
14.00
16.00
16.00
18.00
18.00
Flange Thickness
At Face
At Hub
(t1)
(D1)
in. mm
in. mm
165
222
203
152
178
178
229
229
279
279
305
305
356
356
406
406
457
457
1.38
1.00
1.00
1.13
1.25
1.25
1.75
1.75
2.00
2.00
2.00
2.00
2.13
2.13
2.81
2.81
3.25
3.25
Combination reducers
(flanged small end)
B
35
25
25
29
32
32
44
44
51
51
51
51
54
54
71
71
83
83
1.38
2.00
2.00
2.00
2.00
2.00
2.38
2.38
2.63
2.63
2.88
2.88
3.13
3.13
3.81
3.81
4.25
4.25
Flange Thickness
At Face
At Hub
(t2)
(D2)
in. mm
in. mm
35
51
51
51
51
51
60
60
67
67
73
73
80
80
97
97
108
108
1.13
1.13
1.38
1.00
1.00
1.13
1.13
1.25
1.25
1.75
1.75
2.00
2.00
2.00
2.00
2.13
2.13
2.81
29
29
35
25
25
29
29
32
32
44
44
51
51
51
51
54
54
71
1.13
1.13
1.38
2.00
2.00
2.00
2.00
2.00
2.00
2.38
2.38
2.63
2.63
2.88
2.88
3.13
3.13
3.81
29
29
35
51
51
51
51
51
51
60
60
67
67
73
73
80
80
97
Approx
Wt
lb. kg
4
5
6
9
10
11
15
17
21
23
28
35
45
50
73
84
100
115
1.8
2.3
2.7
4.1
4.5
5.0
6.8
7.7
9.5
10.4
12.7
15.9
20.4
22.7
33.1
38.1
45.4
52.2
Flanges are filament wound with tapered body. Molded flanges available in
2- through 12-inch sizes.
D
Nom
Pipe
Size
in. mm
3x2
4x2
4x3
6x3
6x4
8x4
8x6
10x6
10x8
12x8
12x10
14x10
14x12
16x12
16x14
80x50
100x50
100x80
150x80
150x100
200x100
200x150
250x150
250x200
300x200
300x250
350x250
350x300
400x300
400x350
Laying
Length*
(L)
in. mm
6.25
7.25
7.25
9.25
9.25
11.25
11.25
12.25
12.25
14.25
14.25
16.13
16.13
18.38
18.38
159
184
184
235
235
286
286
311
311
362
362
410
410
467
467
Overall
Length
(B)
in. mm
8.06
9.06
11.06
11.06
11.06
13.06
13.50
14.50
14.75
16.75
17.00
19.88
19.13
22.38
21.88
* Laying length is measured from contact surface to pipe stop in Quick Lock bell.
10
205
230
281
281
281
332
343
368
375
425
432
505
486
568
556
At Face
(t)
in. mm
1.13
1.25
1.25
1.75
1.75
2.00
2.00
2.00
2.00
2.13
2.13
2.82
2.82
3.25
3.25
Flange Thickness
At Hub
(D)
in. mm
29
32
32
44
44
51
51
51
51
54
54
72
72
83
83
2.00
2.00
2.00
2.38
2.38
2.63
2.63
2.88
2.88
3.13
3.13
3.81
3.81
4.25
4.25
51
51
51
60
60
67
67
73
73
80
80
97
97
108
108
Approx
Wt
lb. kg
8
9
10
13
14
18
19
24
29
39
41
59
56
78
82
3.6
4.1
4.5
5.9
6.4
8.2
8.6
10.9
13.2
17.7
18.6
26.8
25.4
35.4
37.2
Ds
L
OD
B
Nom
Pipe
Size
in. mm
1
11 2
2
3
4
6
8
10
12
14
16
Overall
Length
(B)
in. mm
25
40
50
80
100
150
200
250
300
350
400
2.50
2.88
4.00
4.00
4.00
4.88
5.38
5.88
6.38
7.75
8.75
Crosses
12
1.06
1.25
1.81
1.81
1.81
2.25
2.50
2.75
3.00
3.50
4.00
Outside
Dia
(OD)
in. mm
27
32
46
46
46
57
64
70
76
89
102
1.62
2.31
2.81
3.94
5.06
7.19
9.25
11.38
13.38
14.69
16.62
Pipe
Stop
(L)
in. mm
41
59
71
100
129
183
235
289
340
373
422
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.75
0.75
Approx
Wt
Cplg
lb. kg
10
10
10
10
10
10
10
10
10
19
19
0.2
0.3
0.6
0.9
1.4
2.4
4.0
5.0
7.0
12.0
14.0
0.1
0.1
0.3
0.4
0.6
1.1
1.8
2.3
3.2
5.4
6.4
Cap
lb. kg
0.9
1.0
1.2
2.2
3.4
8.4
14.0
22.0
22.0
0.4
0.5
0.5
1.0
1.5
3.8
6.4
10.0
10.0
Crosses are filament wound. Mitered crosses are available in 14- and 16-inch
sizes. Contact Ameron for dimensions and pressure ratings.
Ds
64
73
102
102
102
124
137
149
162
197
222
Socket
Depth
(Ds)
in. mm
Nom
Pipe
Size
in. mm
2
3
4
6
8
10
12
50
80
100
150
200
250
300
Laying
Length
(L)
in. mm
2.50
3.38
4.12
5.62
7.00
8.50
10.00
64
86
105
143
178
216
254
Socket
Depth
(Ds)
in. mm
1.81
1.81
1.81
2.25
2.50
2.75
3.00
46
46
46
57
64
70
76
Approx
Wt
lb. kg
3
6
7
13
23
37
61
1.4
2.7
3.2
5.9
10.4
16.8
27.7
Flanges
Filament-wound and molded flanges correspond to ANSI B16.5 Cl. 150 classification. Sealing ring thicknesses for 1- and 11/2-inch flanges are 0.035; for
2- through 8-inch flanges, 0.047; and for 10- through 16-inch flanges,
0.060, respectively. Molded flanges are indicated with an asterisk (*).See
Assembly Instructions for Bondstrand fiberglass flanges, FP196, for
recommendations on gasket selection, nut and washer dimensions, bolt
lengths and torques, and tightening sequences.
A
BC
Ds
Nom
Pipe
Size
in. mm
1 25
112 40
2 50
3
80
4 100
6 150
8 200
10 250
12 300
14 350
16 400
Flange
Dia
(A)
in. mm
4.25
5.00
6.00
6.00*
7.50
7.50*
9.00
9.00*
11.00
11.00*
13.50
13.50*
16.00
16.00*
19.00
19.00*
21.00
23.50
Bolt
Circle
(BC)
in. mm
108
127
152
152
191
191
229
229
279
279
343
343
406
406
483
483
533
597
3.13
3.88
4.75
4.75
6.00
6.00
7.50
7.50
9.50
9.50
11.75
11.75
14.25
14.25
17.00
17.00
18.75
21.25
Laying
Length
(L)
in. mm
80
99
121
121
152
152
191
191
241
241
298
298
362
362
432
432
476
540
0.063
0.125
0.188
0.188
0.188
0.188
0.188
0.188
0.125
0.125
0.125
0.125
0.125
0.125
0.125
0.125
0.312
0.250
Reducing flanges
2
3
5
5
5
5
5
5
3
3
3
3
3
3
3
3
8
6
Flange Thickness
At Hub
At Face
(D)
(t)
in. mm
in. mm
1.13 29
1.38 35
2.00 51
2.00 51
2.00 51
2.00 51
2.00 51
2.00 51
2.38 60
2.38 60
2.63 67
2.63 67
2.88 73
2.88 73
3.13 80
3.13 80
3.81 97
4.25 108
1.00
1.00
1.13
1.13
1.25
1.56
1.75
1.75
2.00
2.00
2.00
2.00
2.13
2.13
2.81
3.25
Socket
Depth
(Ds)
in. mm
25
25
29
29
32
40
44
44
51
51
51
51
54
54
71
83
Hole
Count
1.06 27
1.25 32
1.82 46
1.82 46
1.82 46
1.82 46
1.82 46
1.82 46
2.25 57
2.25 57
2.50 64
2.50 64
2.75 70
2.75 70
3.00 76
3.00 76
3.50 89
4.00 102
4
4
4
4
4
4
8
8
8
8
8
8
12
12
12
12
12
16
Hole
Dia
Bolt
Dia
in. mm
in. mm
0.63
0.63
0.75
0.75
0.75
0.75
0.75
0.75
0.88
0.88
0.88
0.88
1.00
1.00
1.00
1.00
1.12
1.12
16
16
19
19
19
19
19
19
22
22
22
22
25
25
25
25
28
28
0.50
0.50
0.63
0.63
0.63
0.63
0.63
0.63
0.75
0.75
0.75
0.75
0.88
0.88
0.88
0.88
1.00
1.00
Approx
Wt
13
13
16
16
16
16
16
16
19
19
19
19
22
22
22
22
25
25
lb. kg
1
2
2
2
3
3.
4
4
7
7
10
12
14
16
22
27
37
53
0.5
0.9
0.9
0.9
1.4
1.4
1.8
1.8
3.2
3.2
4.5
5.4
6.4
7.3
10.0
12.2
16.8
24.0
A
BC
Ds
Nom
Pipe
Size
in. mm
2x112
3x2
4x2
4x3
6x3
6x4
8x4
8x6
10x6
10x8
12x8
12x10
50x40
80x50
100x50
100x80
150x80
150x100
200x100
200x150
250x150
250x200
300x200
300x250
Flange
Dia
(A)
in. mm
6.00
7.50
9.00
9.00
11.00
11.00
13.50
13.50
16.00
16.00
19.00
19.00
152
191
229
229
279
279
343
343
406
406
483
483
Bolt
Circle
(BC)
in. mm
4.75
6.00
7.50
7.50
9.50
9.50
11.75
11.75
14.25
14.25
17.00
17.00
121
152
191
191
241
241
298
298
362
362
432
432
Laying
Length
(L)
in. mm
Flange Thickness
At Hub
At Face
(D)
(t)
in. mm
in. mm
in. mm
0.75
0.12
0.12
0.12
0.69
0.69
0.94
0.50
0.75
0.50
0.75
0.50
2.00
1.93
1.93
1.93
2.50
2.50
2.75
2.75
3.00
3.00
3.25
3.25
0.75
0.75
0.75
0.75
0.88
0.88
0.88
0.88
1.00
1.00
1.00
1.00
19
3.
3
3
18
18
24
13
19
13
19
13
51
49
49
49
64
64
70
70
76
76
83
83
1.00
1.12
1.25
1.25
1.75
1.75
2.00
2.00
2.00
2.00
2.12
2.12
25
28
32
32
44
44
51
51
51
51
54
54
Hole
Dia
19
19
19
19
22
22
22
22
25
25
25
25
Hole Socket
Count Depth
(Ds)
in. mm
4
4
8
8
8
8
8
8
12
12
12
12
1.25
1.81
1.81
1.81
1.81
1.81
1.81
2.25
2.25
2.50
2.50
2.75
32
46
46
46
46
46
46
57
57
64
64
70
Bolt
Dia
in. mm
0.63
0.63
0.63
0.63
0.75
0.75
0.75
0.75
0.88
0.88
0.88
0.88
16
16
16
16
19
19
19
19
22
22
22
22
Approx
Wt
lb. kg
2
3
6
5
12
11
21
17
29
24
43
36
0.9
1.4
2.7
2.3
5.4
5.0
9.5
7.7
13.2
10.9
19.5
16.3
13
Adapters are available in Quick-Lock bell x NPT threaded male (M), and QuickLock bell x Victaulic male end (V) configurations. Sizes 1 (25 mm) and 112 are
filament wound; 2 through 6 are compression molded. Consult manufacturer
for dimensions of QL bell x victaulic adapters.
Nom
Pipe
Size
in. mm
B
Ds
ID
NPT
Molded plugs
1
25
112 40
2
50
3
80
4 100
6 150
Overall
Length
(B)
in. mm
2.38
2.81
3.57
4.36
4.63
4.67
Socket
Depth
(Ds)
in. mm
60
71
91
111
118
119
1.06
1.25
1.81
1.81
1.81
2.25
Inside
Dia
(ID)
in. mm
27
32
46
46
46
57
0.76
1.43
1.89
2.80
3.89
5.90
Approx
Wt
lb. kg
19
36
48
71
99
150
0.3
0.4
0.6
1.2
1.6
2.6
0.1
0.2
0.3
0.5
0.7
1.2
50 psi maximum
Nom
Pipe
Size
in. mm
2
3
4
6
8
10
12
Fits
Q/L
Bell
50
80
100
150
200
250
300
Total
Thickness
(T)
in. mm
1.94
1.94
1.94
2.38
2.63
2.88
3.13
Approx
Wt
lb. kg
49
49
49
60
67
73
80
0.6
1.3
2.0
6.0
10.0
17.0
27.0
0.3
0.6
0.9
2.7
4.5
7.7
12.2
50 psi maximum
Nom
Pipe
Size
in. mm
L
Fits
Q/L
Bell
E
16
3x2
4x2
4x3
6x3
6x4
8x4
8x6
10x6
10x8
12x8
12x10
80X50
100x50
100x80
150x80
150x100
200x100
200x150
250x150
250x200
300x200
300x250
Overall
Length
(B)
in. mm
1.94
1.94
1.94
2.38
2.38
2.63
2.63
2.88
2.88
3.13
3.13
49
49
49
60
60
67
67
73
73
80
80
Pipe
Stop
(L)
in. mm
0.13
0.13
0.13
0.56
0.56
0.81
0.38
0.63
0.38
0.63
0.38
3
3
3
14
14
21
10
16
10
16
10
Eccentricity
(E)
in. mm
0.25
0.75
0.13
1.25
0.63
1.63
0.63
1.63
0.63
1.63
0.63
6
19
3
32
16
41
16
41
16
41
16
Approx
Wt
lb. kg
0.7
1.5
0.8
4.1
3.1
8.0
5.0
12.0
7.0
15.0
8.0
0.3
0.7
0.4
1.9
1.4
3.6
2.3
5.4
3.2
6.8
3.6
Nom pipe
Size
in.
mm
1
112
2
25
40
50
80
100
150
200
10
250
12
300
14
350
16
400
150
150 *
150
150*
150
150*
100
100*
100
100*
100
100*
100
100*
Sleeve couplings
psi
10
10*
10
10*
10
10*
7
7*
7
7*
7
7*
7
7*
450
450
450
450
425
350*
400
350
300
250
250
225*
200
175*
170
150*
165
150*
165
150*
bar
31
31
31
31
29
24*
28
24*
21
17*
17
16*
14
12*
12
10*
11
10*
11
10*
Adapters, threaded
Adapters, grooved
psi
bar
200
150*
200
150*
150
100*
150
100*
14
10*
14
10*
10
7*
10
7*
*Note: Pressure ratings for Series 5000 are lower than for other pipe series.
Important notice
This literature and the information and recommendations it contains are based on data reasonably believed to be
reliable. However, such factors as variations in environment, application or installation, changes in operating
procedures, or extrapolation of data may cause different results. Ameron makes no representation or warranty,
express or implied, including warranties of merchantability or fitness for purpose, as to the accuracy, adequacy or
completeness of the recommendations or information contained herein. Ameron assumes no liability whatsoever in
connection with this literature or the information or recommendations it contains.
Europe
Ameron B.V.
J.F. Kennedylaan 7
4191 MZ Geldermalsen
The Netherlands
Tel:
+31 345 587 587
Fax:
+31 345 587 561
info@ameron-fpg.nl
Americas
P.O. Box 878
Burkburnett, TX 76354
Tel: (940) 569-1471
Fax: (940) 569-2764
marcom@ameronfpd.com
Centron International
P.O. Box 490
600 FM 1195 South
Mineral Wells, Texas 76068
Tel: (940) 325-1341
Fax: (940) 325-9681
1991 Ameron FP282B (9/07) supersedes FP282A (5/98) Printed in U.S.A. 5M[186]