Serial Number Checkpoints

1 Antenna port to jumper connector properly joined


2 Outer jumper cable have not a sharp bend
3 Outer jumper cable don't have any damage
4 The cable on VCT is straight and perpendiculur to ground
5 The cable on VCT is straight and perpendiculur to ground
6
In Weather proofing PVC tape is applied at the bottom and
Butyl tape is less than the PVC tape as applied
7
In Weather proofing PVC tape is applied at the bottom and
Butyl tape is less than the PVC tape and Rubber tape is less than butyl
tape
8 The PVC layer after Rubber tape is covering all layers
9 Black color cable ties are used
10 Wheather proofing is done opposite the flow of water
11
The feeder male connector and jumper female connector is properly
joined
12 Outer insulation of feeder cable is removed properly for earthing kit
13 Bending radius of feeder cable is grater than 300mm
14
Earthing kit's grounding cable is placed in downward direction with
no loop
15
Earthing kit's grounding cable is placed in downward direction with
no joint
16
Earthing kit is placed all in a single line and 1.5m from jumper-feeder
connector
17 Earthing kit is connected by a lug propery
18 Cables on HCT are parallel to ground and perpendicular to VCT
19 WFT is properly sealed
20 Z bend hasn't sharp edges
21 Surge Arrester is properly connected to IGB
22 Feeder connector male to S.A.female connector is connected properly
23 Surge Arrester female connector is properly connected to Jumper male
24 The grounding cable in between Surge Arrester and IGB is 16sq. Mm
25 The grounding cable in between EGB and IGB is 35sq.mm
26 13 number nut & bolt used in connection of lug with a SA
27 EGB is properly connected to Grounding pit.
28 Indoor Jumper cable is not routed with a sharp turn
29 Antenna height is according to RF plan
30 Azimuth plane is according to RF plan
31 RF clamp placed at every 1.5 m on VCT
32 RF clamp placed at every 0.6m on HCT
33
34
35
36
37
38
39
40
41
42
Status Punch Points
not ok The port is joined properly but some amount of water drops in it.
not ok The loop used here its radius is too small.
not ok The jumper male connector is broken.
not ok Straight but not perpendiculur to ground
not ok Cable is not straight nor perpendiculur to ground
not ok The butyl tape is greater than PVC tape
not ok The rubber tape is covering butyl tape
not ok The PVC tape on top is lesser than rubber tape
not ok White color cable ties are used
not ok It is made as on the flow of water as aresult water is inside
not ok The port is joined properly but dust paticles are there
not ok Some outer core is also removed
not ok Bending radius is less than 300mm
not ok A loop is there on the earthing kit's grounding cable
not ok A joint is there in between grounding cable and tower
not ok All are not in single line some are at 1.6m some are at 1.4m etc
not ok It is not connected properly
not ok It is not parallel to ground nor perpendicular to HCT
not ok WFT is not properly sealed
not ok There is sharp edges on the WFT
not ok There is loose connection in between Surge Arrester
not ok There cable is loosely connected
not ok There connectors are very tightly connected
not ok wrong cable used it's of 35sq.mm
not ok wrong cable used it's of 16sq.mm
not ok 20 number Nut and bolts are used
not ok The grounding is not properly maintained
not ok There is sharp turn in the routing cable
not ok improper coverage
not ok wrong coverage area is selected
not ok imbalace not symmetric
not ok rf clamp is placed at every 0.6m but it is not in proper line