1

BMS Energy Efficiency


Modbus Control System


































www.ekonhome.com.cn


2

B
M
S


Energy Efficient HVAC System

Features



















Control large number of HVAC
and Lights Simultaneously
Easy to use Graphical User Interface


Simple as 1, 2, 3
1. Select multiple Thermostat \ Lights
or Zones to control
2. Select Settings (Mode, Fan Level,
Set point, Lock Keypad and Light on\off)
3. Press SEND



2 way communication
Show Online the real status of all Air Conditions,
Heating, Lights and Blinds in a building


Status include Set Point Temperature,
Room Temperature, HVAC Mode
(On / Off / Heat / Cold or Auto),
Fan Level, Keypad Unlock / Lock,
Light On or Off and Blinds Open or Close.

3























































Group Control
Select Single or Multiple Zones or Pre Defined
Thermostat and Light and Control them all
by 1 press of a button





Save Energy Fix Set Point
Lock thermostats at optimum set point
and ensure user cannot change it.



Ensure thermostats cannot be turned ON
by user from the thermostat at certain period
of times when unnecessary.

Save Energy Auto Off
Add wireless Motion sensor to power off
Lights and HVAC when room is left empty
for preset period of time

4

B
M
S


















































Simple Setup (no programming)
This is as simple as it can be. If you know
how to setup up you smart phone, you will
know how to setup this BMS system

Each thermostat and light is given an address.
Give it a name. You are done.

User Interface in any Language
Each of the Zones, Thermostats and Scenes
are named in any name and any language you wish



Names can be modified at any time after.
These names are used in messages also

HVAC + LIGHT combined
Thermostat and Light Switches are combined
together on the same device for slick design




Smart Timer Energy Save
Weekly Timer to power On or Off group
of air conditions at certain times

Allow to set holiday dates to bypass the
timer automatically. Optional outdoor
temperature sensor to bypass timer
if outside conditions are idle
5
















































Compatible with Central AirCon
Wirelessly Control Central Air Condition with
remote control via Infrared



Note: thermostat must be matched with
the AirCon brand


Safety First Fire AC shut down
Automatically Power Off all the air conditions
in case of a Fire to ensure fire is not stronger and
smoke is not circulated in AirCon sys.


Interface with Fire Alarm system by
Dry Contact or RS485


All Building/s Control
Control all HVAC and Lights in the
building/s from main control room



Messages Online
System will display messages about any
abnormal status of any device




6



System Layout


Modbus Fan Coil Control System Layout



7



ModBus Touch Screen Thermostat for Fan Coil








Specification
Voltage: 24VDC / 110VAC / 220VAC
Power Consumption: 1.5W
Temperature Range: 10 ~ 30
o
c
Accuracy: 1
o
c
Ambient temperature range: 0 ~ 50
o
c
Housing: ABS flame retardant material
CE standard
Color: Metallic Silver
LCD 5 inch Touch screen
LCD indication: Fan Level, Mode, Lock, Room Temp and Set Point
Surface Mount on wall
Communication distance: maximum 1000 meters (RS485)


Main Features

Communicate with master controller via
Modbus
Control Cold / Hot / Auto mode, Set Point,
Fan 1, 2, 3 and Auto
Can be Locked (disable Manual control)
from master controller
Plug & Play only need power and Bus
Application: Building Automation (retrofit)
and Energy Save
2 way communication (feedback)

8

B
M
S


ModBus Thermostat for Fan Coil















Specification
Voltage: 24VDC / 110VAC / 220VAC
Power Consumption: 1.5W
Temperature Range: 10 ~ 30
o
c
Accuracy: 1
o
c
Ambient temperature range: 0 ~ 50
o
c
Housing: ABS flame retardant material
CE standard
Color: Beige (custom colors for MOQ)
LCD 5 inch. Blue color background (custom colors for MOQ)
LCD indication: Fan Level, Mode, Lock, Room Temp and Set Point
Hand Held Remote control optional
Surface Mount on wall
Size: 150 x 86mm


















Fan Coil Wiring

18mm
deep

Main Features

Communicate with master controller via
Modbus
Control Cold / Hot / Auto mode, Set Point,
Fan 1, 2, 3 and Auto
Can be Locked (disable Manual control)
from master controller
Plug & Play only need power and Bus
Application: Building Automation (retrofit)
and Energy Save
2 way communication (feedback)

86mm
150mm
Surface
mount
9

Optional 2 or 4 pipes Thermostats:




Modbus Thermostat (Fan Coil) & Light Switch






















Main Features

Communicate with master controller
via Modbus
Control Cold / Hot / Auto mode, Set
Point, Fan 1, 2, 3 and Auto
Can be Locked (disable Manual
control) from master controller
Application: Building Automation
(retrofit) and Energy Save
2 way communication (status)
Control 2 LIGHT Loads
LED indication of Light status
Make wall looks more organized
10

B
M
S


Modbus Thermostat for Split Air Condition















IR codes are pre programmed at the factory to match with certain models of air
conditions. Therefore, each module must order to match the specific air condition.
Maximum distance of IR signal is 6 meters in line of sight.


Modbus Thermostat for Split Air Condition & light switch













Main Features

Communicate with master controller
via Modbus
Control Cold / Hot / Auto mode, Set
Point, Fan 1, 2, 3 and Auto
Can be Locked (disable Manual
control) from master controller
Plug & Play only need power
Application: Building Automation and
Energy Save
2 way communication (feedback)

Main Features
Communicate with master controller
via Modbus
Control 2 LIGHT, Loads 10Amp each
Control Cold / Hot / Auto mode, Set
Point, Fan 1, 2, 3 and Auto
Can be Locked (disable Manual
control) from master controller
Application: Building Automation and
Energy Save
2 way communication (status)
LED indication of Light status

IR
IR
11


Modbus Dual Light Switch













Specification

Voltage: 120 / 220VAC at 50/60Hz
Power Consumption: 1.2W
Light Load: 12Amp per channel for resistive load. 8 Amp for low voltage loads. 2 Amp
for inductive loads (Fluorescent and CFL)
LED Status indication for each channel on the button
Optional Motion sensor to power off Light when room left empty for a preset period of
time
Housing: ABS flame retardant material
CE standard
Color: Beige (custom colors for MOQ)
Hand Held Remote control optional
Size: 86 x 86mm














Wall Mount
Fit most European wall box:




60mm diameter 72x72mm
(German Standard) (British Standard)
Main Features

Control 2 LIGHT Loads, 10Amp each
Communicate with master controller
via Modbus
Application: Building Automation and
Energy Save
2 way communication (status)
LED indication of Light status

86mm
86mm
18 45mm


In-Wall
mount
12

B
M
S



Wiring light switch
Connect power and load as follows:


Modbus Single Load Light Switch







Modbus Motorized Control Switch














Main Features

Control 220V motors (up/down)
Communicate with master controller
via Modbus
Application: Building Automation and
Energy Save
2 way communication (status)
LED indication of Light status
Control Blinds, Curtains, etc.

Main Features

Control 1 LIGHT Loads, 10Amp
Communicate with master controller
via Modbus
Application: Building Automation
(retrofit) and Energy Save
2 way communication (status)
LED indication of Light status

13


Master Controller




Main Features

Server Build In
Easy to use GUI in any language
2 way communication
Smart Weekly and Holiday timers
Optional to add touch screen
Plug and Play only power wire and RS485
Grouping Scenes, Groups, Zones, etc.
Can control 32 nodes directly or 128 with RS485 splitter


Specification
Number of Loads
256 loads (thermostat \ light switch \ motor switch) per
Master. Recommended max. 127
Number of Scenes 32 scenes per master (each scene can control all loads)
Master control buttons Zone Thermostat On and Off, All loads On and Off
Control Communication Modbus, RS485
EKON RF communication
Receive Status Request - 2 way communication
Fire Alarm Interface Optional with Dry Contact Via RF or Modbus
RS232 protocol ASCII and HEX (in any combination)
TCP/IP Web Browser
Voltage 110 / 220VAC, 50/60Hz



14

E
C
O
s
e
n
s
e


ECOsense

Save Energy by Automatically and Wirelessly Power off
Air-Condition \ Heater & TV when room is left empty

















































Cut Electricity bills by 20-50%
Learning IR Remote Control
Compatible with most air condition that
has IR remote control
Automatically Turns Off Heating \
Air-Condition when room is left empty
Delay Timer of 15. 30 or 60 min
DIY - No need wires or installation
Wireless, simply fix on wall or ceiling
Best Solution for Green Environment
Low-Cost device with High-Savings
Patent: #200920072195.5

LARGE Energy Savings
Reduce Electric Bill substantially





Up to 50%
Savings

15














Specification

Timer select switch of 15, 30 and 60 minutes
from the time room is left empty till Power Off
commands are sent
Detecting range: <6M at 360
0

IR learning code: 2 IR commands of most devices
(stored in Flash memory also if no battery installed)
IR transmitting range: <6M
IR transmitting direction: one in front and one on side
Voltage: 3VDC (2 AAA batteries)
Size: 60 x 60 x 15 mm
Mounting: optional Ceiling or Wall
Works with IR devices that has discrete OFF command
(one Power button on remote is not compatible)
Not suitable for room with moving objects
(pets, curtains in wind, etc.)
Indoor use only

Learning IR
Compatible with most
Air Condition brands

16































Energy Efficient Solutions




EKON Manufacturing Inc.

EKON China Headquarter

191Rijing Road, Area B, 3
rd
Floor,
Wai Gao Qiao Free Tread Zone,
Pudong District,
Shanghai, China

0086 21 58661899
ekon@ekonhome.com.cn
EKON HOME Inc.

EKON Hong Kong Office

317-319 Des Voeux Road
Central Kai tak /commercial Building,
Room 1208
Hong Kong

00852 800906152
asia@ekonhome.com.cn

Das könnte Ihnen auch gefallen