we make I T happen

2
Datacenter Solutions
Canovate provides IT and Telecom infrastructure technology offerings that span from complete data centers, data center green cooling technology to
ber optic connectivity based FTTX and ber optic transmission and access solutions.
Canovate designs and manufactures a wide range of innovative standard and customized products, technologies and solutions:
Headquarters: ekmeky, stanbul, Trkiye
4,000 customers in more than 60 countries on six continents
300 employees, 50 engineers, 4 academic consultants
ISO 9001 approved
26,000m state-of-the-art ex-Alcatel manufacturing facilities in stanbul
12% of revenue invested into product research, product development and intellectual property-patent developments
Fiber optic connectivity based FTTX
Fiber optic transmission and access
Complete data centers
Data center cooling, PDU, remote monitoring and access
IT 19 network and server racks
Outdoor racks and cabinets
Wall-mount 19 enclosures
Industrial 19 racks, cabinets and enclosures
Frame systems
1965 Established as PTT-ARLA state owned Research Laboratory
1982 Became a private company, TELETA
1984 Alcatel Telecom Exchange System 12 production
1991 ISO 9001 Certication
1993 Merger with ALCATEL
1996 Integration of ERP System
1999 Over 10 Million Subscriber line System 12 Exchange Systems developed, manufactured and delivered worldwide
2003 Relocation to brand new 26.000m
2
purpose built state-of-the-art manufacturing facilities in stanbul
2004 Establishment of structural cabling and ber optic business unit
2005 2 PCT Patents, 3rd Party Compliance Statement for Date and Telecom Products; development of fully integrated high density
Optical Distribution
Frame (ODF) Systems.
2006 Launch of Basic Outdoor Cabinet, Seismic 19 Rack Systems, Announcement of RoHS conformity,
Gost-R Certication, IP41 up to IP65 approvals for cabinets and enclosures, UL approvals and renewals
2009 3rd PCT Patent, Launch of Data Center business unit including patented green cooling technology
2010 4th PCT Patent, Launch of advanced high-density, industry rst, Troy Fiber Optic ODF System
2011 Establishment of ber optic cable termination manufacturing lines and devolopment IP PDU

About Us
Key Customers
Canovate Facts
Milestones
DATACENTER SOLUTIONS
Cold & Hot Aisle Containment
Front Cooling System
Side Cooling System
Direct Cooling
Security
1U Fire Extinguisher System with Novec 1230
Rack Monitoring System
Environmental Monitoring System
All-in-one Compact Datacenter
FLOOR STANDING CABINETS
Inorax-AL
Network Cabinet
Server Cabinet
Components of Inorax-AL
Inorax-ST
Network Cabinet
Server Cabinet
Components of Inorax-ST
inorax-AL High End Server Rack Cabinet
Seismic Rack
ETSI Cabinet
Open Frame Rack Cabinet
Patch Rack
Industrial Cabinet
Thermal Cabinet
WALLMOUNT CABINETS
Single Wallmount Cabinet with Fixed Side Panels
Single Wallmount Cabinet with Openable Side Panels From Outside
Single Wallmount Cabinet with Openable Side Panels From Inside
Double Section Wallmount Cabinet
Slim Line Wallmount Cabinet
Single Wallmount Cabinet
19 SOHO Cabinet
10 SOHO Cabinet
ACCESSORIES
inorax OUTDOOR Enclosures
Outdoor Cabinets
inorax-09 Outdoor Cabinet
inorax-10 Outdoor Cabinet
inorax-11 Outdoor Cabinet
inorax-12 Outdoor Cabinet
inorax-13 Outdoor Cabinet
inorax-14 Outdoor Cabinet
inorax-15 Outdoor Cabinet
inorax-16 Outdoor Cabinet
inorax-17 Outdoor Cabinet
Thermal Management
PDUs
Basic PDU
Metered PDUs
Protected PDU
Extendable PDU
DC-PDU
IP PDU
4-23
8
10
12
16
19
20
20
20
25-26
27-54
27
28
29
30-38
39-47
39
40
41-47
49
50
51
52
53
53
54
55-59
56
56
57
57
58
58
59
59
60-66
67-73
68
69
70
70
70
71
71
71
72
72
73
74-79
75
76
76
77
78
79
Index
4
Datacenter Solutions
+
Cold & Hot Aisle Containment System
Cold Aisle Containment + Front Cooler
Enables isolation of hot and cold aisles to maximize cooling system
efciency and minimize cooling energy requirement
Highly modular, scalable, expandable, and retrot-able
Optimum cooling solution for big and medium scale datacenters
coupled with CRAC units to increase efciency of cooling system.
Provides moderate efciency, energy saving and free cooling ca-
pabilities
Advantages:
More efcient than traditional central CRAC cooling technologies
- up to 50% energy savings
Modular, scalable, expandable, retrot-able
Cold / Hot Aisle Containment &Front
Cooler Application (+Free Cooling)
Rack & Front Cooler
Application (+Free Cooling)
Chiller + Free Cooling
Side Cooler (Inrack Cooling)
Application (+Free Cooling)
Cold & Hot Aisle Containment System coupled with front cooler
system ensures ultimate cooling capacity enabling highest levels of
energy efciency
Optimum solution for medium to large scale datacenters
A chilled-water based technology bringing cold air right to the server
racks where heat dissipation is maximum, eliminating raised oor re-
quirement in contrast to CRAC cooling systems.
Advantages:
Eliminates raised oor requirement
Ultimately more efcient than traditional CRAC based cooling
Industry leading cooling capacity enabled by 60kW Front Cooling
System
Water based cooling A totally Green IT
Free-cooling capability is signicantly higher than CRAC cooling
systems, for ambient temperatures below 14
0
C
+
5
Datacenter Solutions
Rack & CRAC Application
CRAC Units
Cold Aisle Containment
& CRAC Application
Side Cooler
Front Cooler
Front Cooler is an ultimate solution for medium to large scale data-
center applications
A chilled-water based technology bringing cold air right to the server
racks where heat dissipation is maximum, eliminating raised oor re-
quirement in contrast to CRAC cooling systems
Integration into Cold & Hot Aisle Containment Systems yields indus-
try leading cooling efciency performance
Advantages:
Signicantly more efcient than traditional CRAC based cooling
Free-cooling capability is considerably higher than CRAC units (<=
14
0
C)
Eliminates raised oor requirement
Water based cooling A totally Green IT
Industry leading cooling capacity up to 60kW
C
a
p
ac
i
t
y
C
o
olin
g

up to
60kW
The perfect t to high density standalone racks where thermal load
exceeds 30 kW or for small computer server rooms where infrastruc-
ture is limited for necessary expansions
Highly efcient for small to medium size enterprises, institutions and
branch ofces
Side cooling system is a chilled-water based solution that is fully
integrated to one or either side of IP protected racks and provides
individual or standalone rack cooling up to 30 kW
One side cooling system can serve up to three server cabinets with
10kW thermal load each
Advantages:
Ideal for high density server racks and small datacenters
Individual and standalone rack cooling capacity up to 30kw
Water based cooling A totally Green IT
Eliminates raised oor requirement
Free-cooling capability is signicantly higher than CRAC cooling
systems, for ambient temperatures below 14
0
C
C
a
p
ac
i
t
y
C
o
olin
g

up to
30

kW

W: 600 mm W: 300 mm
6
Datacenter Solutions
The most important thing is to recognize that there is no single answer and a detailed engineering energy analysis. A custom Total Cost of Ownership analysis
must be undertaken for each decision.
Here are some guidelines for various scenarios:
Nothing is perfect, all can be improved. This maxim is at the heart of Canovates principles. In its industry, Canovate can rightfully claim to be the leader in quality
and technology, and as such, we aim to keep setting new standards. Indeed, this applies in particular to the companys product range, which is consistently
geared towards signicantly lowering the consumption of fossil fuels, lowering emissions, and gradually replacing them with renewable sources of energy as
possible. Everrising energy costs mean that the emphasis is on reducing the consumption of energy consumption as quickly as possible. Canovate Cooling
Technologies offer industry leading energy efciencies. Taking the overall investment and current energy prices into consideration, cooling technology is the
most economical alternative. At the same time, the cooling technology is also futureproof. This is why you should invest today in advanced cooling technol-
ogy. The savings you can make through this are considerable. Make an effective contribution towards the sustained protection of the climate by preventing
unnecessary CO2 emissions. Canovate works consistently on new, environmentally responsible solutions. The result is environmentally friendly, cost effective
and efcient heating systems.
Increasing compute capabilities in data centers has resulted in corresponding increases in rack and room power densities. How to cool these new higher-
powered racks is a question that challenges all data center managers. In the past it was sufcient to roll in new servers and just add computer room air condi-
tioners (CRAC units) around the perimeter, as a result less engineering was required. However, todays IT equipment can push data centers to 40kW per rack
and the cooling challenges and costs are much more obvious. It is no wonder that at a 2009 Data Center Users Group meeting, the 107 participants listed as
their top three facility and network concerns:
Heat Density-Cooling
Power Density
Energy Efciency
The power density trend will continue to challenge cooling technology. For instance, a full rack of the densest servers in 2011 will require about 40 kW of power
in operation and cooling (heat removal). This matches our experience with the peak power draw of a full rack of dual processor peak-performance quad-core
blade servers. From now until 2014, the trend should linearly increase to roughly 60 kW per rack when fully congured with the latest equipment.
Green IT
Existing extension
Understand the limits of the existing data center
Implement all best practices
Consider enhanced airow segregation
Add cooling technology
1
Retrot or existing building conversion
Understand the baseline capabilities of the building
Perform detailed engineering analysis
Total Cost of Ownership evaluation for optimum cooling technology
2
Brand new facility
Understand rack power values peak and homogeneity
Plan for high density if possible
Implement cooling technology where possible for lowest cost to build and lowest cost to operate
3
7
Datacenter Solutions
Tape Storage
H
e
a
t

L
o
a
d

i
n

k
W

P
e
r

R
a
c
k
Storage Servers
Compute Servers (2U and Greater)
1992
30
20
10
0
1994 1996 1998 2000 2002 2004 2006 2008 2010 2012 2014
4
Compute Servers (1U, Blade and Custom)
Courtesy : Adapted from ASHRAEs projected density loads (kW per Rack) for IT equipment
8
Datacenter Solutions
Manual or electronic locking
Sliding Door systems for access
management.
Protection from dust
Hinged or Sliding Doors
Hinged Doors
Brush
Skirt Type Blanking Panel
Sliding Doors
Raised Floor
Blanking Panels
Closes the gap between 19 mounting
rails and side panels. Enables zero U
paton panol htting and oablo
management.
Cold & Hot Aisle Containment
Systom must bo built on raisod hoor
to maximizo oold air intako ohoionoy.
Easily removable acrylic
glass panel to maximize
the available light and
roduoo hro risk.
Top Covers
Cold & Hot Aisle Containment
Energy savings up to 50%
Modular Concept
Retroftable
Cooling capacity of up to 10kW per rack
Green IT
Complete system solution:
Power management
Monitoring
Cooling
Security
Efficient energy management
ROI within 30 months
Increase server performance and cooling
efficiency in Datacenters
9
Datacenter Solutions
Product Code Product Code
Product Code
Product Code
Product Code
Product Code
Product Code
Product Code
Product Code
Product Description Product Description
Product Description
Product Description
Product Description
Product Description
Product Description
Product Description
Product Description
DC-T-X-YY3Y0
DC-T-X-YY6Y0
DC-T-X-YY8Y0
DC-D1-X-42200
DC-D1-X-42210
DC-D1-X-42220
DC-D1-X-47200
DC-D1-X-47210
DC-D1-X-47220
DC-D4-X-42200
DC-D4-X-42210
DC-D4-X-42220
DC-D4-X-47200
DC-D4-X-47210
DC-D4-X-47220
DC-D3-X-422Y0
DC-D3-X-472Y0
1 pc Left Door Panel, 1 pc Right Door Panel, 2
pcs Hydraulic Door Closer Systems, 1 pc Bolt
Plate, 1 pc Screw Set,
DC-B1-X-YY3Y0
DC-B1-X-YY6Y0
DC-B1-X-YY8Y0
DC-B1-X-YY3Y0
DC-B1-X-YY6Y0
DC-B1-X-YY8Y0
DC-B2-X-42Y00
DC-B2-X-42Y10
DC-B2-X-42Y20
DC-B2-X-47Y00
DC-B2-X-47Y10
DC-B2-X-47Y20
CCA-X-4001
CCA-X-4003
DC-D4-X-P
DC-D4-X-K
DC-D4-X-C
DC-D4-X-S
DC-B3-X-428Y0
DC-B3-X-478Y0
First and Last Frame Proles on Top Cov-
er Frame for Sliding Door Applications
Frame Proles on Top Cover Frame
Brush Set Between Floor and Cabinet
Gasket Sealings
Sliding Door Manual System
Sliding Door Automatic System
Swing Type Door Panel Set
Others
Skirt Type Blanking Panel
For 300 mm width cabinet
For 600 mm width cabinet
For 800 mm width cabinet
For 1000 mm depth cabinet
For 1100 mm depth cabinet
For 1200 mm depth cabinet
For 1000 mm depth cabinet
For 1100 mm depth cabinet
For 1200 mm depth cabinet
For 1000 mm depth cabinet
For 1100 mm depth cabinet
For 1200 mm depth cabinet
For 1000 mm depth cabinet
For 1100 mm depth cabinet
For 1200 mm depth cabinet
For 42U cabinets
For 47U cabinets
For 300 mm width Cabinet
For 600 mm width Cabinet
For 800 mm width Cabinet
For 300 mm width Cabinet
For 600 mm width Cabinet
For 800 mm width Cabinet
For 42U 1000 mm depth Cabinet
For 42U 1100 mm depth Cabinet
For 42U 1200 mm depth Cabinet
For 47U 1000 mm depth Cabinet
For 47U 1100 mm depth Cabinet
For 47U 1200 mm depth Cabinet
19 1U Blanking Panel
19 2U Blanking Panel
Fingerprint Reader
Key Pad
Card Reader
Key
For 42U Cabinet
For 47U Cabinet
2 pcs Blanking Panel between 19 mounting rail and
cabinet prole (for 800 mm width cabinet)
Top Cover Aisle Entrance Door Accessories
10
Datacenter Solutions
Front Cooler
DC-F1-X-420300
DC-F1-X-420320
DC-F1-X-420600
Front Cooler 30 kW 42U 300 X 1000
Front Cooler 30 kW 42U 300 X 1200
Front Cooler 60 kW 42U 600 X 1000
Front Cooler 60 kW 42U 600 X 1200
Product Code Description
30 kW
24 kW
38 C
5 x
axial
3.800 m/h
980 Watt
2,8 A
230 Volt/50 Hz.
+14 C
+20 C
4,8 m/h
42 kPa
1 inch.
1 x
G 2
62 dB(A)
300 mm
1.000 mm
2.000 mm
153 kg.
RAL 9005 / RAL 7035
DC-F1-X-420300
DC-F1-X-420320
DC-F1-X-420600
DC-F1-X-420620
Specifications
Cooling capacity
Cooling capacity sensible
Air intel
Number of fans
Type of fans
Air how
Powor oonsumption
Currency
Powor supply
Water temperature inlet
Water temperature outlet
Wator how
Pressure drop
Water connection
Numbor o airhltor
Typo o airhltor
Noise level in 1 mtr.
distance
Dimensions
Breadth
Depth
Height
Weight
Color

60 kW
60 kW
38 C
3 x
axial
9.600 m/n
980 Watt
5,8 A
230 volt750 Hz.
+14 C
+20 C
7,11 m/n
33 kPa
1 1/2 inch.
1 x
G 2
72 dB(A)
600 mm
1.000 mm
2.000 mm
252 kg.
RAL 9005 / RAL 7035
DC-F1-X-420620
C
a
p
ac
i
t
y
C
o
olin
g

up to
60 kW
Pressure Controlled
Fans
ed
Liquid (Water)based cooling
Specially developed for cold&hot aisle containment applications
Modular construction
In Row Technology
No raised floor required
Variable speed fans
Modular design: Allows capacity expansion
30 kW or 60 kW cooling capacity
Pressure controlled fans
Hot-swappable fans
EC-Technology
No condenser needed water due to 14
0
C inlet water
temperature
Increased freecooling capacity enabled by high
inlet watertemperature @ 14
0
C
Efficient power consumption: 980 Watt for 60 kW Cooling
DX (Refrigerant R 410A) based cooling
28 kW cooling capacity in 42U 300x1000 Cabinet
Automatically controlled between 11 to 28 kW by
inverter technology for maximum energy efficiency
COP ratio is above 4 for better energy efficieny
Outside placed Compressor unit to have better noise level
The cooling units work 100% sensible (without condenswater)
Specially developed for cold&hot aisle containment applications
Modular construction
In Row Technology
No raised floor required
Variable speed fans - EC-Technology
Modular design: Allows capacity expansion
Hot-swappable fans
Controller
11
Datacenter Solutions
Front Cooler Control & Monitoring System
Cold Aisle Containment
Canovate Cold & Hot Aisle Containment Application
Chiller
W
a
r
m

A
i
r

<
2
5
0
C
W
a
r
m

A
i
r

<
2
5
0
C
22-23
0
C
Uniform
Temp.
Uniform
Temp.
22-23
0
C
22-23
0
C 22-23
0
C
No Need For Raised Floor
A Snapshot from Front Cooler Control & Monitoring System
12
Datacenter Solutions
Side Cooler
Liquid based cooling
No raised floor needed
30 kW cooling capacity
Efficient power consumption
Easy adaptation to different racks
Mountable to the side of the rack
Easy installation on the existing racks
Patented space saving shape
Integrated monitoring system
Hot-swappable fans
300 mm width
No condensing water due to 14
0
C
inlet water temperature
More than 1000 installations worldwide
LCD Controller
C
a
p
ac
i
t
y
C
o
olin
g

up to
30 kW
DC-S1-X-420300
DC-S1-X-420320
Specifications
Cooling capacity
Cooling capacity sensible
Air intel
Number of fans
Type of fans
Air how
Powor oonsumption
Currency
Powor supply
Water temperature inlet
Water temperature outlet
Wator how
Pressure drop
Water connection
Numbor o airhltor
Typo o airhltor
Noise level in 1 mtr.
distance
Dimensions
Breadth
Depth
Height
Weight
Color

DC-S1-X-420300
DC-S1-X-420320
Side Cooler 30 kW 42U 300 X 1000
Side Cooler 30 kW 42U 300 X 1200
Product Code Description
30 kW
24 kW
38 C
5 x
axial
3.800 m/h
980 Watt
2,8 A
230 Volt/50 Hz.
+14 C
+20 C
4,8 m/h
42 kPa
1 inch.
1 x
G 2
62 dB(A)
300 mm
1.000 mm
2.000 mm
153 kg.
RAL 9005 / RAL 7035
Hydrolic system
Automated Door Release
13
Datacenter Solutions
M
Automatic
Circuit Shifter
Chiller 1 /
Chiller 2 /
FreeCooler
t
AU
= t
FK
< 10 C
Chiller 1
6
Racks 42 HE
Hight : 2.000 mm
Width : 800 mm
Depth : 1.200 mm
Chiller
Cooling Power : 30,0 kW
Width : 1.822 mm
Heigth : 1.510 mm
Width : 695 mm
Weight : 320 kg.
M
Chiller 2
redundant
Automatic
Circuit Shifter
FreeCooler
One
Glykol -Back Cooler
Type bm- fh 102a/2x3
Cooling Power: 70 kW
Length: 3.520 mm
Weight: 490 kg
Width: 1.380 mm
Height: 1.565 mm
Fre rr eCoole
One
M
Circuit S
Chiller 1
Chiller 2
Circuit S
Automat
Circuit SShifter
/
/
M
hifter
ic
hifter
h
o
W
er
er
C
re rr
M
Chiller 1
M
Fre rr eCooler
t
A
t
U
= t
FK
< 10
idth 1 822
Weig
hiller
ooling Power : 30,0 kW
idth 1 822
Automatic
Circuit Shi e fte
a
W
e
a
W
De
Ra
Hi
W
Side Cooler (continued)
A Reference Side Cooler Application Layout
A Snapshot from Side Cooler Control & Monitoring System
Side Cooler Control & Monitoring System
14
Datacenter Solutions
Cold & Hot Aisle Containment + Front Cooler
+
Cold Aisle Containment
Canovate Cold & Hot Aisle Containment Application
Cold & Hot Aisle Containment + Front Cooler (In Row Cooling)
Chiller
Comparison PUE of different Cooling solutions for Datacenter with 500 kW IT-load
FreeCooling No Indirect Indirect Indirect
FreeCooling 100% <=2C <=13C <=15C
technic CRAC standard Cold Aisle CRAC Cold Aisle FC SideCooler
% kW % kW % kW % kW
IT Equipment 59,9% 500 72,3% 500 76,1% 500 79,5% 500
Cooling 24,0% 200 18,8% 130 15,2% 100 12,7% 80
Air Movement 9,6% 80 4,3% 30 3,8% 25 2,7% 17
USV 6,0% 50 4,3% 30 4,6% 30 4,8% 30
Lightening etc. 0,6% 5 0,3% 2 0,3% 2 0,3% 2
energy costs (): 294.336 168.192 131.400 101.966
(12 cent / kwh)
100% 835 100% 692 100% 657 100% 629
6 , 1 : E U P 7 1,38 1,31 1,26
Energy costs % 289% 165% 129% 100%
ROI (Return of Investment) = Onl y 2 Years!
15
Datacenter Solutions
16
Datacenter Solutions
17
Datacenter Solutions
24
18
0
6
- 6
- 12
100%
Direct Free Cooling
FreeCooling
Direct Free Cooling
Inside datacenters, after apropriate filteration, cold external ambient air is injected by air channels. The external air is drawn
directly from the direct freecooling unit. This is done using a dumper controlled by the microprocessor. In direct freecooling
systems liquid tranfer is not needed as water or any other agent as in direct free cooling systems. Direct free cooling is used in
ICT facilities with lower heat loads like base stations for mobile phone networks ets.
3d Drawing of Direct Free
Cooling Application
C
a
p
ac
i
t
y
F
r
e
e
Coo
l
i
n
g
up to
95%
18
Datacenter Solutions
Formulation of task:
High-availability computer centre
High-security computer centre
Highest possible energy efciency
As little air conditioning as possible in the computer centre room itself
Limited space available for installing air conditioning
Computer centre situated directly under the roof
Computer centre oor space: 200 m
IT load: 2.5 kw/m =6 kW / rack
Requirements:
Cooling capacity: 500 kW.
Redundancy: N+1
Minimisation of air conditioning costs
Solution:
The layout of our Direct Free Cooling Units (DFCUs) was specially adapted to the roof and computer centre layout for roof installation.
The DFCUs draw in cold air up to an outdoor temperature of 22 C.
As required, the cold air is mixed via mixing dampers to obtain the required intake temperature.
No mechanical cooling is required for this mode of operation.
In Germany, on the basis of the mean values of the last 15 years, the direct free cooling is between 94% and 97% per year.
Outgoing air Double oor
Air intake Exhaust air
Three DFCUs with 250 kW cooling capacity each are installed.
All three units function at 66% of their maximum cooling capacity in normal operation.
Only if one unit fails (back-up mode), the other two units are driven at maximum capacity.
Fig. 2: DFCUs in roof installation with 3 x 250 kW cooling capacity
DFCUs in roof installation with 3 x 250 kW cooling capacity
Schematic sketch of the Direct Free Cooling Units (DFCU) roof installation
Air Out
Air In
Raised Floor
Return
Air
19
Datacenter Solutions
Functional principle:
Cold air is led directly to the double oor via air intake ducts. The cold air is blown through the perforated plates in front of the 19-
inch racks. The air cools the servers and is dissipated as warm air at the rear of the racks. This air is led to special air-return ducts
and then returned to the DFCUs. In summer operation, the warm air is dissipated directly to the outside. In winter operation, part of
the warm air is mixed with the intake air for the double oor. In winter operation, a special energy-saving nozzle humidifying device
maintains the pre-dened humidity level in the humidifying strip.
In the remaining time per year during which machine cooling is necessary (around 500 hours), this function is performed by a cooling
register integrated in the DFCUs. The cooling components (compressors and condensers) are located in the front of the DFCUs. The
entire cooling equipment is therefore on the roof, outside of the computer centre itself.
To optimise energy efciency, the cooling rows in the computer centre are enclosed in a housing. This minimises the temperature
gradient from the oor of the racks to the top of the racks.
Result:
No mechanical cooling is required at outside temperatures below 22 C.
The compressors only operate around 5% per year.
With a power usage effectiveness (PUE) of 1.17, this is one of the worlds most energy-efcient computer centres.
There is no air-conditioning equipment in the computer centre itself. 100% of the computer centre oor space is available for IT.
The lightweight design does not impair the statics of the building.
The enclosure of the cooling rows in a housing further optimises the system.
Power consumption 500 kW cooling capacity
Lightning etc. =Lighting etc.
1,17 =1.17
Energy Consumption for 500 kW Cooling Capacity
Energy efciency / PUE:
% kW
IT equipmenta 85.6% 500
Cooling 2.1% 12
Air movement 7.9% 46
UPS 4.3 % 25
Lighting etc. 0.2 % 1
100% 584
PUE = 1.17
A
Direct Free Cooling Data Center with 2 * 4000 kW Cooling Capacity / PUE /1,18
20
Datacenter Solutions
Canovate Front and Side Coolers require an inlet temperature of 14 C to operate efficiently and to avoid condensation during
operation. In the solid (appx.90 meters deep) there is a constant temperature of 11 C, we can use this temperature to cool
water required for the cooling units and eliminate the need of using chiller units. The glycol-water returns with app. 11C from
the underground pipe with pumps. The supply temperature to the Front&Side Cooler of 14C is regulated by the three-way
valve. In front&Side Cooler units the water-glycol mix will gain a temperature of appx. 19C and the closed cycle transfers the
heat of the IT equipment to the ground.
ROI for such an investment is approximately 18 months
Using Geothermal Cooling for the
direct rack and in row cooling
fromhydr. System
(Geothermic or.
FreeCooler )
to
hydr. System
(Geothermic)
Coolmanager
Sole
12-14C
Sole
25C
Q =68 kW
VL =14 C
RL =20 C
Air Separator
Air Separator
-
Soil
M
FreeCooler
tAU =tFK <11 C
(optional)
G
r
e
e
n
I
T
!
G
r
e
e
n
I
T
!
21
Datacenter Solutions
Intelligent Lock and IP Controlled Access
Convenient and user friendly control and management of access to high security cabinets and zones. Both electronic lock system and IP based
Electronic Lock systems can be used in indoor and outdoor applications. Key-pad, door lock mechanism, lock controller and management
software are included.
User-Friendly online central management with graphical interface
Graphical interface customization with addition of cabinet location
scheme, including graphics and photos
Fast access to locks via Ethernet(10/100 Mbps)
Event log based on date, hour, minute with database
Retrospective event query
Audio and visual warnings for switching On&Off, wrong action,
remaining open, etc.
'|s. | .s...gs s.d s's.s Jse. '.Jg' '\'
/ .Je.s' \sse. ,sss..d de|.ed |. ,e..g s'' 'e ''s
'se. ,sss..d s, |e de|.ed . ~ c .Je.s' 's.se.s ss des.ed
Cryptographic (Hash) storage for passwords in the database
Password resetting functionality with software
Cabinet blocking after consecutive incorrect password entries
Deactivating desired cabinets via the management panel
Central monitoring of open and closed cabinets
10/100 Mbps Ethernet connection
2 levels password management
C||.e ,e.s. .'e. ds..e.g
Ability to run on batteries in power failure
Ergonomic, industrial and elegant design
Easy of use with Push-Button functionality
Automatic locking when the lever is shunt
User-Friendly warnings; Lan, Er, Ok
CONTROLLER MODULE
CONTROLLER MODULE
Intelligent Lock & Management
Security
Product Code Product Description
SL-00-KP
SL-00-HL
SL-00-CM
SL-00-MS
Intelligent Lock Management
Numpad
Lock and Handle
Control Module
Management Solfware
22
Datacenter Solutions
Environmental Monitoring System with wireless sensors
In addition to the standard environmental monitoring functions, Canovate en-
vironmental monitoring module has additional features like; Timely control of
the devices connected to its control outputs, logging, and integration with
the central management softwares by using its standard SNMP support.
Timing functions can be used to start cooling, heating and watering in a
predetermined time slices within a day. Or any industrial device can be con-
trolled
Features
Supports all FCC compliance, UL94 standards
100Mbit Ethernet connection
Embedded Web server.
Supports wirelless sensor connections
4 channels temperature -20C - 120C
4 channels humidity 0rH - 99rH
2 channels RS232/RS485
2 channels 2KWatt dry contact relay output
1 channel Frame Camera input.
4 channels digital input
Time slicing functions (timely control of outlets in a day)
Up to 2 different time programs
e-mail basic authentication (SMTP Client)
SNMP Trap
Precision timing Access to NTP servers by using SNTP (Time Protocol)
Two users support (1 Admin and 1 standard user)
User selectable alarm types and events (Inputs and sensors).
User assignable http port (80-8080),
Monitoring access port by using UDP(245)
2 dry contact outputs ( 240VAC/10A max)
Size: 112x100x29mm / 4.41x3.94x1.14 inch
Patented hardware and software topology..Patent No:2010311
112,22 mm
1U Fire Extinguisher System with Novec1230
Rack Monitoring System
Data center managers are faced daily with the task of keeping servers cool
enough to perform optimally in order to reduce energy wasted by overcool-
ing. To succeed at this delicate balancing act, managers must collect stra-
tegic environmental data and have a rapid means to respond to changes in
conditions. The Environmental Monitor + Relays provides IT managers with
the information and tools needed to minimize excess cooling and maximize
uptime. Remote sensors selected for your specic installation are monitored
and alarmed based on user dened thresholds. Relay control actions are
congured to respond to conditions which are outside acceptable ranges.
Site managers can circumvent overheating through event trigger actuation of
air conditioners, vents or sirens for audible alarming. These simple and timely
precautions optimize energy efciency.
OneU active extinguishing system The integrated smoke aspiration system
continuously takes air samples from the entire switch cabinet that it is pro-
tecting through a sampling pipe with several openings which is installed in
the switch cabinet. The smoke aspiration system is usually equipped with
high-sensitive and normal-sensitive smoke detectors. In this way, two differ-
ent alarm thresholds are provided for the graduated combination of device
shutdown and re. The evaluation of measured values by an intelligent mi-
crocontroller enables OneU to detect re with very low tolerance for error.
Optionally, the OneU active extinguishing system may also be connected to
an external manual re alarm for manual activation. The integrated extinguishing system consists mainly of a light metal container with the
extinguishing agent Novec 1230, an release mechanism with valve and cartridge with propellant, loss monitoring for the extinguishing agent
and the OneU discharge nozzle. During extinguishing, the cartridge with propellant is opened and the liquid agent ows to the OneU nozzle.
The special geometry ensures that the agent is vaporised when exiting the nozzle and its full extinguishing effect is unfolded.
T I F E N E B E R U T A E F
On board scrolling display
On-board temperature sensor
6 I/O sensor ports
4 Remote climate sensor ports
3 Internal control relays
Threshold alarms
Interfaces with IP web cameras
Accessible via any web browser
Provides local reading of user selected critical data
Current status and trend data for temperature conditions
Ability to monitor contact closure devices or scale 0-5V signals
/dd sdd.s' e,e.sJ.e. s.| .. 'Jd, s.d de. ,. se.s.s
Control external devices such as air conditioners, heaters, vents, sirens, etc. to counteract unacceptable site conditions
C.ve.e. .|s. vs es'. ''\' .s,s s.d/. `\'
Visual monitoring of cabinet or computer room
ss, .ss''s. s.d s.e.s.e ' ee..s' s|.s.e \e. dss g.s,'s s.d s.s',e 's.s' 'gs
Novec1230
Product Code
Product Code
Product Code
Product Code
Product Description
Product Description
Product Description
Product Description
SF-01-SM-H
SF-01-DM-0
SF-01-SD-H
SM-00-BM-42-C
SM-00-SM-42-C
SM-00-WM-42-C
SM-01-BM-164-C
SM-00-ST-XX
SM-00-SH-XX
SM-00-SC-XX
SM-00-SW-XX
SM-00-SS-XX
SM-00-SD-XX
XX = 03:3M, 06:6M, 09:9M, 0W :Wireless
Environmental Monitoring System
Environmental Monitoring System
Sensors
Suppression Module
Smoke Aspiration Detection Module
Active Fire Suppression
Basic Module
SMS Module
Wireless Sensor Conneciton
Basic Module
Temperature
Humidity Sensor
Temperature and humidity
Water detector
Smoke detector
Door contact
23
Datacenter Solutions
we make IT happen
All-in-one Compact Datacenter
24
Datacenter Solutions
IP PDU
Full turnkey datacenter including cooling, structured cabling, monitoring, power management and protection
Scalable from 1 rack to hundreds of racks
Stand alone datacenter
No raised foor needed
Individual rack cooling up to 30 kW
High level security with in rack fre protection and monitoring systems
Advanced power management with IP PDU and UPS systems
Internal and external redundancy
Structured cabling solutions with overhead cable channels
Door Contact
Liquid Sensor
Air Flow Sensor
1U Fire Extinguisher System
with Novec 1230
Rack Monitoring System
Structured Cabling
Cable Partitions
Rack Monitoring
System&Sensors
Moduler UPS
All-in-one Compact Datacenter
25
Datacenter Solutions
Side Cooling System Cabinet
Modular UPS
1U Fire Extinguisher System
with Novec1230
Cable Partitions
Rack Monitoring System
IP PDU
All-in-one
Compact
Data Center
IP PDU
All-in-one Compact Datacenter
26
Datacenter Solutions
Micro Datacenter
Door Contact
Liquid Sensor
Air Flow Sensor
1U Fire Extinguisher
System with
Novec1230
Moduler UPS
All-in-one datacenter including cooling, monitoring, power management and protection
Stand-alone datacenter
Eliminates raised foor and external coolng equpment requirements
Individual rack cooling up to 4 kW
High level security with in rack fre protection and monitoring systems
Advanced power management enabled by IP PDU and UPS systems
C
a
p
ac
i
t
y
C
o
olin
g

up to
4 kW
Rack Monitoring System
IP PDU
Micro
Datacenter
27
inorax-AL Cabinets
In todays and future datacenter trends, the most important factors to be considered are power distribution, cooling and cable
management on rack level. Efficiently engineered rack mounting capabilities and capacity become most critical feature to opti-
mize utilization of available space. Canovate offers ideal rack enclosure technologies offering innovative, flexible, stylish and cost
effective form, fit and function; whether it is a datacenter, a server room or a stand-alone application.
You can choose from two different rack cabinets based on two alternative frame technologies according to your exact require-
ments and specifications:
Ultimate Thermal Management
Over 80% of todays IT managers identify thermal management as
their greatest challenge. This is no surprise considering the aver-
age heat load generated per cabinet by new equipment has dou-
bled since year 2000. Creating a properly congured cabinet that
works with your cooling system to control airow and maximize
cooling effectiveness which is vital to overall success.
Efcient Cable Management & Power Distribution
Convenient network cable management, power distribution and
ber management options designed for ber and copper cables,
meeting your highest-density cabling requirements and future
network growth. Single, three-phase and IP PDUs can easily be
mounted to match your connectivity and monitoring requirements.
inorax-ST
Network & Server Rack Cabinets
inorax-AL
Network & Server Rack Cabinets
inorax Network & Server Rack Cabinets
Its patented aluminum modular frame technology, capabilities and ex-
ceptional strength make this model unique and stand out in terms of
providing industry leading structural rigidity, better access, optimized
available mounting space and ease of installation, not to mention wide
range of interoperable accessory range. Available as at-pack.
Designed according to very high structural rigidity requirements
Industry leading static load carrying capacity exceeding 2000KG
Lighter weight frame technology enabling ease of transport and con-
venient handling
Higher corrosion resistance
Interlocking bolt-on and heavy-duty modular frame joints, an innova-
tive weld-free technology
Easy to assemble and completely disassemble in a matter of minutes
Ultimate cosmetic appearance
High strength steel based modular or fully welded patent-pending
frame technology and wide range of conguration options makes it
a cost-effective reliable solution offering optimized available mounting
space and ease of installation. Available as at-pack.
Designed according to high structural rigidity requirements
Static load carrying capacity exceeding 1500KG
Interlocking bolt-on and heavy-duty top and bottom frames
Easy to assemble and completely disassemble in a matter of minutes
Appealing cosmetic appearance
nets
d ex-
ms of
mized
wide
G
con-
nova-
nutes
28
inorax-AL Cabinets
inorax-AL Network Rack Cabinet
Inorax-AL network rack cabinet system offers the best solution for IT and
Telecom applications in dense and complex cabling environments. A wide
range of cable management accessories is available to ensure perfect
management of copper & ber cables and 19 equipment. Vertical 19
mounting rails can be adjusted freely through the depth, which simplies
mounting of any device and conguration of connecting cables. Black tint-
ed left and right sections on the front glass door hides the excess cables
from the view of the user and gives an aesthetic look to the rack. Flat-pack
option enables savings up to 60% in the transport cost and warehouse
space.
Technical Features
Front door with safety glass
Solid Side Panels with cylindrical locks and latches
Solid Rear Panel with cylindrical locks
Internal top sheet with 3 cable entry and fan cut-outs
2 Pairs of depth adjustable heavy duty 19 Mounting Rails
2 Pairs of Adjustable Feet
Front Door with swing-handle single point lock
Color RAL 7035 or RAL 9005
RoHS compliant, UL and Gost-R Certied
26U
26U
26U
32U
32U
32U
36U
36U
36U
39U
42U
42U
42U
42U
42U
47U
47U
47U
47U
47U
600
600
800
600
600
800
600
600
800
800
600
600
600
800
800
600
600
600
800
800
600
800
800
600
800
800
600
800
800
800
600
800
1000
800
1000
600
800
1000
800
1000
1322
1322
1322
1589
1589
1589
1767
1767
1767
1900
2033
2033
2033
2033
2033
2255
2255
2255
2255
2255
1187
1187
1187
1454
1454
1454
1632
1632
1632
1765
1898
1898
1898
1898
1898
2120
2120
2120
2120
2120
503
503
703
503
503
703
503
503
703
703
503
503
503
703
703
503
503
503
703
703
550
750
750
550
750
750
550
750
750
750
550
750
950
750
950
550
750
950
750
950
56,72
74,17
83,94
67,16
82,78
95,28
74,12
88,52
102,84
108,51
84,56
97,14
102,88
114,18
119,05
93,26
104,33
120,10
123,64
130,14
129-429
129-629
129-629
129-429
129-629
129-629
129-429
129-629
129-629
129-629
129-429
129-629
129-829
129-629
129-829
129-429
129-629
129-829
129-629
129-829
CPN-X-2666A
CPN-X-2668A
CPN-X-2688A
CPN-X-3266A
CPN-X-3268A
CPN-X-3288A
CPN-X-3666A
CPN-X-3668A
CPN-X-3688A
CPN-X-3988A
CPN-X-4266A
CPN-X-4268A
CPN-X-4260A
CPN-X-4288A
CPN-X-4280A
CPN-X-4766A
CPN-X-4768A
CPN-X-4760A
CPN-X-4788A
CPN-X-4780A
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
Height
U
Outer Width
(W) mm
Outer Depth
(D) mm
Outer Height
(H) mm
Inner Height
(h1) mm
Inner Width
(w1) mm
Inner Depth
(d1) mm
19 Rails Adjustable
Depth Range (c)
Weight
kg
Part No
Order Information
Material
Color
Maximum Static Load
Finish
Compliance
Packaging
Frame ; Anodized aluminum extrusion proles
Other parts : 1,2 and 2 mm steel
Up to 2000 kg.
Doors, side panels, top and bottom covers:
Electrostatic Powder Paint,19 mounting rails: Zinc-plated
RAL 7035 or RAL 9005
RoHS, UL Certied
Assembled or unassembled
d1 c
w1
H
W
D
h1
Standard Conguration:
Related Accessories Cable Organizer-
Blanking Panels
Cable Channels
29
inorax-AL Cabinets
Frame ; Anodized aluminum extrusion proles
Other parts : 1,2 and 2 mm steel
Frame, doors, side panels, top and bottom covers
Electrostatic Powder Paint, 19 mounting rails: Zinc-plated
26U
26U
36U
36U
39U
42U
42U
42U
42U
42U
42U
47U
47U
47U
47U
47U
47U
600
600
600
600
800
600
600
600
800
800
800
600
600
600
800
800
800
1000
1200
1000
1200
1000
1000
1100
1200
1000
1100
1200
1000
1100
1200
1000
1100
1200
1322
1322
1767
1767
1900
2033
2033
2033
2033
2033
2033
2255
2255
2255
2255
2255
2255
1187
1187
1632
1632
1765
1898
1898
1898
1898
1898
1898
2120
2120
2120
2120
2120
2120
503
503
503
503
703
503
503
503
703
703
703
503
503
503
703
703
703
950
1150
950
1150
950
950
1050
1150
950
1050
1150
950
1050
1150
950
1050
1150
75,45
95,55
94,88
113,88
111,45
106,48
115,65
124,82
117,28
126,34
135,40
116,18
125,07
133,97
126,71
135,51
144,31
129 - 829
129 -1029
129 - 829
129 - 1029
129 - 829
129 - 829
129-929
129-1029
129-829
129-929
129-1029
129-829
129-929
129-1029
129-829
129-929
129-1029
CPS-X-2660A
CPS-X-2662A
CPS-X-3660A
CPS-X-3662A
CPS-X-3980A
CPS-X-4260A
CPS-X-4261A
CPS-X-4262A
CPS-X-4280A
CPS-X-4281A
CPS-X-4282A
CPS-X-4760A
CPS-X-4761A
CPS-X-4762A
CPS-X-4780A
CPS-X-4781A
CPS-X-4782A
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
Height
U
Outer Width
(W) mm
Outer Depth
(D) mm
Outer Height
(H) mm
Inner Height
(h1) mm
Inner Width
(w1) mm
Inner Depth
(d1) mm
19 Rails Adjustable
Depth Range (c)
Weight
kg
Part No
Order Information
inorax-AL Server Rack Cabinet
The ultimate server rack cabinet system ever developed for complex data-
center environments. inorax-AL server rack cabinet system is the ultimate
solution designed and engineered for demanding datacenter environ-
ments. It is designed to house all servers manufactured by major brands
including HP, Dell, Sun, Cisco, Juniper, IBM, Compaq to name a few. To
achieve optimum versatility within the server rack, users can set multiple
depths throughout the cabinet by adjustable 19 mounting rails mounted
on heavy duty side supports. Horizontally divided side panels provide ease
of access and convenient post-installation maintenance. Optional % 80
perforations on front and rear doors enable optimum airow within the rack
cabinet and industry leading static load carrying capacity of the aluminum
extruded frame satises the most of all standards specied for Tier-4 da-
tacenter. Optional cable tray channels can be tted on top of the rack
provides perfect cable routing eliminating the need for raised oor systems.
Flat-pack option enables savings up to 60% in the transport cost and ware-
house space.
H
d1 c
W
D
w1
h1
Technical Features
Perforated front and rear doors, Free Air Ratio (FAR): %67
Front & rear doors with swing handle Multi point-espagnolette
Split side panels
Bottom sheet
Internal top sheet with 3 cable entry and fan cut-outs
2 Pairs of depth adjustable heavy duty 19 Mounting Rails
2 Pairs of Adjustable Feet
Color RAL 7035 or RAL 9005
RoHS compliant, UL and Gost-R Certicated
Material
Color
Maximum Static Load
Finish
Compliance
Packaging
Up to 2000 kg. (in 600x600 mm)
RAL 7035 or RAL 9005
RoHS, UL Certied
Assembled or unassembled
Standard Conguration:
Related Accessories Rack Monitoring System
Power Distribution Units
Integral Console
30
inorax-AL Cabinets
Page :29
Page :30
Page :31
Page :32
Page :33
Page :34
Page :35
31
inorax-AL Cabinets
Components of Inorax-AL
1- Aluminum Frame
2 - Top Sheet
3 - Bottom Sheet
4 - 19 Mounting Rails
5 - Side Support Rail
6 - Side Panel Options
7 - Front Door Options
8 - Rear Door Options
9 - Adjustable Feet
10 - External Top Cover
11 - Plinth
12 - Castor
4
3
7
11 12
2
5
6
9
10
1
8
32
inorax-AL Cabinets
Material
Material
Material
Material
Finish
Finish
Finish
Finish
Maximum Static Load
Color
Color
Anodized Aluminum Extrusion
1.2 mm Steel
1.2 mm Steel
2 mm Steel
Anodic Oxidation (Eloxal)
Electrostatic Powder Paint
Electrostatic Powder Paint
Zinc Plated
2000 kg
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)
600
600
600
800
600
600
800
600
600
600
600
800
800
800
600
600
600
600
600
800
800
800
800
600
600
600
600
800
800
800
600
800
1000
800
600
800
800
600
800
1000
1200
800
800
1000
600
800
1000
1100
1200
800
1000
1100
1200
600
800
1000
1200
800
1000
1200
16,00
17,28
18,66
26,22
16,40
17,71
26,60
16,65
17,98
19,42
20,97
26,84
26,96
29,93
17,03
18,39
19,86
20,65
21,45
27,15
30,14
31,79
33,45
17,33
18,72
20,21
21,83
27,46
30,48
33,83
1308,8
1308,8
1308,8
1308,8
1575,5
1575,5
1575,5
1753,3
1753,3
1753,3
1753,3
1753,3
1886,6
1886,6
2020
2020
2020
2020
2020
2020
2020
2020
2020
2242,25
2242,25
2242,25
2242,25
2242,25
2242,25
2242,25
26U
26U
26U
26U
32U
32U
32U
36U
36U
36U
36U
36U
39U
39U
42U
42U
42U
42U
42U
42U
42U
42U
42U
47U
47U
47U
47U
47U
47U
47U
CPZ-0-26660-0100
CPZ-0-26680-0100
CPZ-0-26600-0100
CPZ-0-26880-0100
CPZ-0-32660-0100
CPZ-0-32680-0100
CPZ-0-32880-0100
CPZ-0-36660-0100
CPZ-0-36680-0100
CPZ-0-36600-0100
CPZ-0-36620-0100
CPZ-0-36880-0100
CPZ-0-39880-0100
CPZ-0-39800-0100
CPZ-0-42660-0100
CPZ-0-42680-0100
CPZ-0-42600-0100
CPZ-0-42610-0100
CPZ-0-42620-0100
CPZ-0-42880-0100
CPZ-0-42800-0100
CPZ-0-42810-0100
CPZ-0-42820-0100
CPZ-0-47660-0100
CPZ-0-47680-0100
CPZ-0-47600-0100
CPZ-0-47620-0100
CPZ-0-47880-0100
CPZ-0-47800-0100
CPZ-0-47820-0100
W (mm) D (mm) Weight kg H (mm) H (U) Part No
Components of Inorax-AL
600
600
600
600
600
800
800
800
800
600
600
600
600
600
800
800
800
800
600
800
1000
1100
1200
800
1000
1100
1200
600
800
1000
1100
1200
800
1000
1100
1200
600
600
600
600
600
800
800
800
800
3,24
4,34
5,82
6,25
7,80
5,76
5,92
6,39
6,96
4,49
5,76
7,05
7,82
8,6
7,11
9,12
10,12
11,12
0,75
0,80
0,85
0,87
0,90
0,85
0,92
0,97
1,02
7
7
7
7
7
7
7
7
7
30
30
30
30
30
30
30
30
30
600
800
1000
1100
1200
800
1000
1100
1200
CPZ-X-YY660-0402
CPZ-X-YY680-0402
CPZ-X-YY600-0402
CPZ-X-YY610-0402
CPZ-X-YY620-0402
CPZ-X-YY880-0402
CPZ-X-YY800-0402
CPZ-X-YY810-0402
CPZ-X-YY820-0402
CPZ-X-YY660-0404
CPZ-X-YY680-0404
CPZ-X-YY600-0404
CPZ-X-YY610-0404
CPZ-X-YY620-0404
CPZ-X-YY880-0404
CPZ-X-YY800-0404
CPZ-X-YY810-0404
CPZ-X-YY820-0404
CPZ-0-YY660-0700
CPZ-0-YY680-0700
CPZ-0-YY600-0700
CPZ-0-YY610-0700
CPZ-0-YY620-0700
CPZ-0-YY880-0700
CPZ-0-YY800-0700
CPZ-0-YY810-0700
CPZ-0-YY820-0700
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
W (mm)
W (mm)
D (mm)
D (mm)
Cabinet W (mm)
Weight kg
Weight kg
Weight kg
H (mm)
H (mm)
Cabinet D (mm)
Part No
Part No
Part No
Frame
Top Sheet
External Top Cover
Side Support Rails





H
W
D


7
H
W


7
H
W
33
inorax-AL Cabinets
Material
Material
Material
Finish
Finish
Finish
Color
Color
1.2 mm Steel
2 mm Steel
1,2 mm Steel and Plastic Hinges
Electrostatic Powder Paint
Zinc-Plated
Electrostatic Powder Paint
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)
600
600
600
600
600
800
800
800
800
600
800
1000
1100
1200
800
1000
1100
1200
1,84
2,45
3,06
3,37
3,67
2,45
3,06
3,37
3,67
5
5
5
5
5
5
5
5
5
CPZ-X-YY660-0403
CPZ-X-YY680-0403
CPZ-X-YY600-0403
CPZ-X-YY610-0403
CPZ-X-YY620-0403
CPZ-X-YY880-0403
CPZ-X-YY800-0403
CPZ-X-YY810-0403
CPZ-X-YY820-0403
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
W (mm) D (mm) Weight kg H (mm) Part No
Bottom Sheet
19 Mounting Rails
Side Panel
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
33
33
33
33
33
33
52
52
52
52
52
52
1,52
1,85
2,08
2,25
2,42
2,7
1198
1464
1642
1776
1909
2131
26U
32U
36U
39U
42U
47U
CPZ-0-26YY0-0600
CPZ-0-32YY0-0600
CPZ-0-36YY0-0600
CPZ-0-39YY0-0600
CPZ-0-42YY0-0600
CPZ-0-47YY0-0600
W (mm) D (mm) Weight kg H (mm) H (U) Part No
600
800
1000
600
800
600
800
800
600
800
600
800
10
10
10
10
10
10
10
10
10
10
10
10
7,11
9,46
12,58
8,53
11,35
9,49
12,62
13,57
10,93
14,54
12,13
16,13
1264
1264
1264
1531
1531
1709
1709
1842
1975
1975
2198
2198
26U
26U
26U
32U
32U
36U
36U
39U
42U
42U
47U
47U
CPZ-X-26Y60-0501
CPZ-X-26Y80-0501
CPZ-X-26Y00-0501
CPZ-X-32Y60-0501
CPZ-X-32Y80-0501
CPZ-X-36Y60-0501
CPZ-X-36Y80-0501
CPZ-X-39Y80-0501
CPZ-X-42Y60-0501
CPZ-X-42Y80-0501
CPZ-X-47Y60-0501
CPZ-X-47Y80-0501
W (mm) D (mm) Weight kg H (mm) H (U) Part No
Material Perforation Rate
Finish
Color
1.2 mm Steel 82%
Electrostatic Powder Paint
RAL 7035 (Light Grey) and RAL 9005 (Black)
High Perforation Rated Formed Curved Door
600
600
800
600
800
600
800
57
57
76
57
76
57
76
9,61
12,75
17,20
14,63
18,38
16,20
20,36
1264
1709
1842
1975
1975
2198
2198
26U
36U
39U
42U
42U
47U
47U
CPZ-X-266Y0-0914
CPZ-X-366Y0-0914
CPZ-X-398Y0-0914
CPZ-X-426Y0-0914
CPZ-X-428Y0-0914
CPZ-X-476Y0-0914
CPZ-X-478Y0-0914
W (mm) D (mm) Weight kg H (mm) H (U) Part No
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)



H
W
D



H
W
D



H
W
D

D
W
Formed Pattern
Perforation with 82%
34
inorax-AL Cabinets
1000
1200
1000
1000
1100
1200
1000
1100
1200
10
10
10
10
10
10
10
10
10
16,79
22,33
18,06
19,33
23,67
25,71
21,46
25,00
28,54
1709
1709
1842
1975
1975
1975
2198
2198
2198
36U
36U
39U
42U
42U
42U
47U
47U
47U
CPZ-X-36Y00-0503
CPZ-X-36Y20-0503
CPZ-X-39Y00-0503
CPZ-X-42Y00-0503
CPZ-X-42Y10-0503
CPZ-X-42Y20-0503
CPZ-X-47Y00-0503
CPZ-X-47Y10-0503
CPZ-X-47Y20-0503
W (mm) D (mm) Weight kg H (mm) H (U) Part No
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
Material
Material
Material
Finish
Finish
Finish
Color
Color
Color
1.2 mm Steel
1.2 mm Steel
1.2 mm Steel
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)
Split Side Panel
Rear Metal Solid Panel
Metal Solid Door
600
800
600
800
600
800
800
600
800
600
800
23
23
23
23
23
23
23
23
23
23
23
8,40
11,59
10,09
13,92
11,21
15,47
16,62
12,89
17,79
14,29
19,72
1264
1264
1531
1531
1709
1709
1842
1975
1975
2198
2198
26U
26U
32U
32U
36U
36U
39U
42U
42U
47U
47U
CPZ-X-266Y0-0901
CPZ-X-268Y0-0901
CPZ-X-326Y0-0901
CPZ-X-328Y0-0901
CPZ-X-366Y0-0901
CPZ-X-368Y0-0901
CPZ-X-398Y0-0901
CPZ-X-426Y0-0901
CPZ-X-428Y0-0901
CPZ-X-476Y0-0901
CPZ-X-478Y0-0901
W (mm) D (mm) Weight kg H (mm) H (U) Part No
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
600
800
600
800
600
800
800
600
800
600
800
10
10
10
10
10
10
10
10
10
10
10
11,08
13,74
13,15
16,31
14,50
17,98
19,24
16,54
20,51
18,24
22,62
1264
1264
1531
1531
1709
1709
1842
1975
1975
2198
2198
26U
26U
32U
32U
36U
36U
39U
42U
42U
47U
47U
CPZ-X-266Y0-0902
CPZ-X-268Y0-0902
CPZ-X-326Y0-0902
CPZ-X-328Y0-0902
CPZ-X-366Y0-0902
CPZ-X-368Y0-0902
CPZ-X-398Y0-0902
CPZ-X-426Y0-0902
CPZ-X-428Y0-0902
CPZ-X-476Y0-0902
CPZ-X-478Y0-0902
W (mm) D (mm) Weight kg H (mm) H (U) Part No
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
Material
Finish
Color
1.2 mm Steel,3 mm Tempered Glass, tinted on left and right sides
Electrostatic Powder Paint
RAL 7035 (Light Grey) and RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
Glass Door Supported By Metal Brackets
600
800
600
800
600
800
800
600
800
600
800
19
19
19
19
19
19
19
19
19
19
19
9,41
11,86
11,29
14,23
12,55
15,81
17,00
14,43
18,18
16,00
20,16
1264
1264
1531
1531
1709
1709
1842
1975
1975
2198
2198
26U
26U
32U
32U
36U
36U
39U
42U
42U
47U
47U
CPZ-X-266Y0-0903
CPZ-X-268Y0-0903
CPZ-X-326Y0-0903
CPZ-X-328Y0-0903
CPZ-X-366Y0-0903
CPZ-X-368Y0-0903
CPZ-X-398Y0-0903
CPZ-X-426Y0-0903
CPZ-X-428Y0-0903
CPZ-X-476Y0-0903
CPZ-X-478Y0-0903
W (mm) D (mm) Weight kg H (mm) H (U) Part No



H
W
D



H
W
D



6
0

H
W

W
H
D
35
inorax-AL Cabinets
Material
Material
Material
Material
Perforation Rate
Perforation Rate
Perforation Rate
Finish
Finish
Finish
Finish
Color
Color
Color
Color
1.2 mm Steel
1.2 mm Steel
1.2 mm Steel
1.2 mm Steel, 3 mm Tempered Glass
69%
67%
67%
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
Perforated Curved Door
Perforated Flat Door
600
600
800
600
800
600
800
600
600
800
600
800
600
800
57
57
76
57
76
57
76
19
19
19
19
19
19
19
9,41
12,55
17,00
14,43
18,18
16,00
20,16
8,21
11,35
15,50
12,23
16,08
14,90
18,86
1264
1709
1842
1975
1975
2198
2198
1264
1709
1842
1975
1975
2198
2198
26U
36U
39U
42U
42U
47U
47U
26U
36U
39U
42U
42U
47U
47U
CPZ-X-266Y0-0905
CPZ-X-366Y0-0905
CPZ-X-398Y0-0905
CPZ-X-426Y0-0905
CPZ-X-428Y0-0905
CPZ-X-476Y0-0905
CPZ-X-478Y0-0905
CPZ-X-266Y0-0904
CPZ-X-366Y0-0904
CPZ-X-398Y0-0904
CPZ-X-426Y0-0904
CPZ-X-428Y0-0904
CPZ-X-476Y0-0904
CPZ-X-478Y0-0904
W (mm)
W (mm)
D (mm)
D (mm)
Weight kg
Weight kg
H (mm)
H (mm)
H (U)
H (U)
Part No
Part No
Perforated Double Flat Door
Double Glass Door
600
600
800
600
800
600
800
19
19
19
19
19
19
19
8,38
10,14
13,53
11,45
14,40
12,57
15,74
1264
1709
1842
1975
1975
2198
2198
26U
36U
39U
42U
42U
47U
47U
CPZ-X-266Y0-0908
CPZ-X-366Y0-0908
CPZ-X-398Y0-0908
CPZ-X-426Y0-0908
CPZ-X-428Y0-0908
CPZ-X-476Y0-0908
CPZ-X-478Y0-0908
W (mm) D (mm) Weight kg H (mm) H (U) Part No
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
800
800
19
19
20,66
22,70
1975
2198
42U
47U
CPZ-X-428Y0-0907
CPZ-X-478Y0-0907
W (mm) D (mm) Weight kg H (mm) H (U) Part No
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
W
H
D

W
H
D
W
H
D



H
W
D
36
inorax-AL Cabinets
Finish
Color RAL 7035 (Light Grey) and RAL 9005 (Black)
Double Metal Solid Door
800
800
19
19
20,81
23,12
1975
2198
42U
47U
CPZ-X-428Y0-0906
CPZ-X-478Y0-0906
W (mm) D (mm) Weight kg H (mm) H (U) Part No
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
High Perforation Rated Flat Door
High Perforation Rated Curved Door
High Perforation Rated Double Flat Door
600
600
800
600
800
600
600
800
600
800
600
600
800
600
800
600
800
19
19
19
19
19
57
57
76
57
76
19
19
19
19
19
19
19
7,91
11,93
15,78
14,60
18,56
9,10
14,13
17,88
15,70
19,86
8,08
9,84
13,23
11,15
14,10
12,27
15,44
1264
1975
1975
2198
2198
1264
1975
1975
2198
2198
1264
1709
1842
1975
1975
2198
2198
26U
42U
42U
47U
47U
26U
42U
42U
47U
47U
26U
36U
39U
42U
42U
47U
47U
CPZ-X-266Y0-0909
CPZ-X-426Y0-0909
CPZ-X-428Y0-0909
CPZ-X-476Y0-0909
CPZ-X-478Y0-0909
CPZ-X-266Y0-0910
CPZ-X-426Y0-0910
CPZ-X-428Y0-0910
CPZ-X-476Y0-0910
CPZ-X-478Y0-0910
CPZ-X-266Y0-0911
CPZ-X-366Y0-0911
CPZ-X-398Y0-0911
CPZ-X-426Y0-0911
CPZ-X-428Y0-0911
CPZ-X-476Y0-0911
CPZ-X-478Y0-0911
W (mm)
W (mm)
W (mm)
D (mm)
D (mm)
D (mm)
Weight kg
Weight kg
Weight kg
H (mm)
H (mm)
H (mm)
H (U)
H (U)
H (U)
Part No
Part No
Part No
Material 1.2 mm Steel, Electrostatic Powder Paint
Material
Material
Material
Perforation Rate
Perforation Rate
Perforation Rate
Finish
Finish
Finish
Color
Color
Color
1.2 mm Steel
1.2 mm Steel
1.2 mm Steel
80%
80%
80%
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)

H
W
D


H
W W
D



H
W W
D


H
W
D
Formed Pattern
Perforation with 80%
Formed Pattern
Perforation with 82%
37
inorax-AL Cabinets
High Perforation Rated Curved Door for Colocation Cabinets
600
800
57
76
10,20
11,32
1975
1975
21U+21U
21U+21U
CPZ-X-426Y0-0912
CPZ-X-428Y0-0912
W (mm) D (mm) Weight kg H (mm) H (U) Part No
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
Material
Material
Perforation Rate
Perforation Rate
Finish
Finish
Color
Color
1.2 mm Steel
1.2 mm Steel
71%
82%
Electrostatic Powder Paint
Electrostatic Powder Paint
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)
Formed Perforated Curved Door
600
600
800
600
800
600
800
57
57
76
57
76
57
76
9,81
12,95
17,40
14,83
18,58
16,40
20,56
1264
1709
1842
1975
1975
2198
2198
26U
36U
39U
42U
42U
47U
47U
CPZ-X-266Y0-0913
CPZ-X-366Y0-0913
CPZ-X-398Y0-0913
CPZ-X-426Y0-0913
CPZ-X-428Y0-0913
CPZ-X-476Y0-0913
CPZ-X-478Y0-0913
W (mm) D (mm) Weight kg H (mm) H (U) Part No
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)




H
H
D
W


H
W
D
Formed Pattern
Perforation with 71%
Formed Pattern
Perforation with 82%
38
inorax-AL Cabinets
Material
Material
Material
Material
Material
Material
Material
Packaging
Packaging
Packaging
Packaging
Packaging
Packaging
Packaging
Finish
Finish
Part No
Part No
Part No
Part No
Part No
Steel and Plastic ABS
Steel and Plastic ABS
Polyamide
Polyamide
Polyamide
Zinc
Zinc
4 pcs in a box
2 pcs with stopper and 2 pcs without Stopper in a box
1 pc in a box
1 pc in a box
1 pc in a box
1 pc in a box
1 pc in a box
Zinc Plated
Zinc Plated
CPZ-0-YYYY0-1005
CPZ-0-YYYY0-1003
CPZ-0-YYYY0-1004
CPZ-0-YYYY0-1001
CPZ-0-YYYY0-1002
Adjustable Feet Castor Set
Multi Point Lock for Double Doors
Single Point Lock
Multi Point Lock for Single Perforated Door
0.35
0.77
600 kg / piece
250 kg / piece
CCA-0-7014
CCA-0-7015
Set Weight kg
Set Weight kg
Maximum Static Load
Maximum Static Load
Part No
Part No
Material
P k i
Cylindrical Lock for Side Panel
Cylindrical Lock for Rear Metal Solid Panel
12
60
10
22
92
47
12 23 12
85
12
55
47
38
55
39
inorax-ST Cabinets
inorax-ST Network Cabinet
Inorax-ST, a cost effective network rack cabinet system fullls high density
cabling and data center requirements. With its modular structure, a practi-
cal option for your future plans. Offers advanced ber and copper cable
management options; helps simplify cable installation and maintenance
while providing maximum cable capacity for your high-density cabling re-
quirements. A wide range of cable management accessories is available
to ensure perfect management of copper, ber cables and 19 equipment.
Flat-pack option enables savings up to 60% in the transport cost and ware-
house space.
Technical Features
Front door with safety glass
Solid Side Panels with cylindrical locks and latches
Solid Rear Panel with cylindrical locks
Internal top sheet with 3 cable entry and fan cut-outs
2 Pairs of depth adjustable heavy duty 19 Mounting Rails
2 Pairs of Adjustable Feet
Front Door with swing-handle single point lock
Color RAL 7035 or RAL 9005
RoHS compliant, UL and Gost-R Certicated
16U
22U
22U
26U
26U
26U
32U
32U
32U
36U
36U
36U
39U
42U
42U
42U
42U
42U
47U
47U
47U
47U
47U
600
600
600
600
600
800
600
600
800
600
600
800
800
600
600
600
800
800
600
600
600
800
800
600
600
800
600
800
800
600
800
800
600
800
800
800
600
800
1000
800
1000
600
800
1000
800
1000
878
1144
1144
1322
1322
1322
1588
1588
1588
1766
1766
1766
1900
2033
2033
2033
2033
2033
2255
2255
2255
2255
2255
718
984
984
1162
1162
1162
1428
1428
1428
1723
1723
1723
1740
1873
1873
1873
1873
1873
2095
2095
2095
2095
2095
503
503
503
503
503
703
503
503
703
503
503
703
703
503
503
503
703
703
503
503
503
703
703
550
550
750
550
750
750
550
750
750
550
750
750
750
550
750
950
750
950
550
750
950
750
950
52,82
62,21
70,66
68,49
77,60
91,62
77,88
88,01
103,14
84,17
94,95
109,81
115.56
93,62
105,41
113,85
121,31
133,54
101,47
114,09
123,20
130,91
144,10
123 - 373
123 - 373
123 - 573
123 - 373
123 - 573
123 - 573
123 - 373
123 - 573
123 - 573
123 - 373
123 - 573
123 - 573
123 - 573
123 - 373
123 - 573
123 - 773
123 - 573
123 - 773
123 - 373
123 - 573
123 - 773
123 - 573
123 - 773
CSN-X-1666A
CSN-X-2266A
CSN-X-2268A
CSN-X-2666A
CSN-X-2668A
CSN-X-2688A
CSN-X-3266A
CSN-X-3268A
CSN-X-3288A
CSN-X-3666A
CSN-X-3668A
CSN-X-3688A
CSN-X-3988A
CSN-X-4266A
CSN-X-4268A
CSN-X-4260A
CSN-X-4288A
CSN-X-4280A
CSN-X-4766A
CSN-X-4768A
CSN-X-4760A
CSN-X-4788A
CSN-X-4780A
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
Height
U
Outer Width
(W) mm
Outer Depth
(D) mm
Outer Height
(H) mm
Inner Height
(h1) mm
Inner Width
(w1) mm
Inner Depth
(d1) mm
19 Rails Adjustable
Depth Range (c)
Weight
kg
Part No
Order Information
Material
Color
Maximum Static Load
Finish
Compliance
Packaging
1,2 - 1,5 - 2mm Steel
Up to 2000 kg.
Doors, side panels, top and bottom covers
Electrostatic Powder Paint, 19 mounting rails: Zinc-plated
RAL 7035 or RAL 9005
RoHS, UL Certicated
Assembled or unassembled
d1 c
w1
H
W
D
h1
Standard Conguration:
Related Accessories Cable Organizer-
Blanking Panels
Cable Channels
40
inorax-ST Cabinets
1,2 - 1,5 - 2mm Steel
Frame, doors, side panels, top and bottom covers
Electrostatic Powder Paint, 19 mounting rails: Zinc-plated
26U
26U
36U
36U
39U
42U
42U
42U
42U
42U
42U
47U
47U
47U
47U
47U
47U
600
600
600
600
800
600
600
600
800
800
800
600
600
600
800
800
800
1000
1200
1000
1200
1000
1000
1100
1200
1000
1100
1200
1000
1100
1200
1000
1100
1200
1322
1322
1766
1766
1900
2033
2033
2033
2033
2033
2033
2255
2255
2255
2255
2255
2255
1162
1162
1723
1723
1740
1873
1873
1873
1873
1873
1873
2095
2095
2095
2095
2095
2095
503
503
503
503
703
503
503
503
703
703
703
503
503
503
703
703
703
950
1150
950
1150
950
950
1050
1150
950
1050
1150
950
1050
1150
950
1050
1150
84,09
95,78
104,79
116,48
130,19
117,21
123,05
128,9
136,88
143,63
150,48
126,72
132,98
139,25
147,31
154,47
161,74
123 - 773
123 - 973
123 - 773
123 - 973
123 - 773
123 - 773
123 - 873
123 - 973
123 - 773
123 - 873
123 - 973
123 - 773
123 - 873
123 - 973
123 - 773
123 - 873
123 - 973
CSS-X-2660A
CSS-X-2662A
CSS-X-3660A
CSS-X-3662A
CSS-X-3980A
CSS-X-4260A
CSS-X-4261A
CSS-X-4262A
CSS-X-4280A
CSS-X-4281A
CSS-X-4282A
CSS-X-4760A
CSS-X-4761A
CSS-X-4762A
CSS-X-4780A
CSS-X-4781A
CSS-X-4782A
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
Height
U
Outer Width
(W) mm
Outer Depth
(D) mm
Outer Height
(H) mm
Inner Height
(h1) mm
Inner Width
(w1) mm
Inner Depth
(d1) mm
19 Rails Adjustable
Depth Range (c)
Weight
kg
Part No
Order Information
inorax-ST Server Cabinet
A cost effective server rack cabinet system developed for independent
use and datacenter environments. inorax-ST server rack cabinet system
is designed and engineered for demanding datacenter environments. It
is designed to house all servers manufactured by major brands including
HP, Dell, Sun, Cisco, Juniper, IBM, Compaq to name a few. To achieve
optimum versatility within the server rack, users can set multiple depths
throughout the cabinet by adjustable 19 mounting rails mounted on heavy
duty side supports. Horizontally divided side panels provide ease of access
and convenient post-installation maintenance. Optional % 80 perforations
on front and rear doors enable optimum airow within the rack cabinet. Op-
tional cable tray channels can be tted on top of the rack provides perfect
cable routing eliminating the need for raised oor systems. Flat-pack option
enables savings up to 60% in the transport cost and warehouse space.
Technical Features
Perforated front and rear doors, Free Air Ratio (FAR): %67
Front & rear doors with swing handle Multi point-espagnolette
Solid Side Panels with cylindrical locks and latches
Internal top sheet with 3 cable entry and fan cut-outs
2 Pairs of depth adjustable heavy duty 19 Mounting Rails
2 Pairs of Adjustable Feet
Color RAL 7035 or RAL 9005
RoHS compliant, UL and Gost-R Certicated
Material
Color
Maximum Static Load
Finish
Compliance
Packaging
Up to 2000 kg. (in 600x600 mm)
RAL 7035 or RAL 9005
RoHS, UL Certied Gost-R Certicated
Assembled or unassembled
Standard Conguration:
Related Accessories Rack Monitoring System
Power Distribution Units
Integral Console
d1
c
W
D
w1
W i ht P t N
D
W
H
h1
41
inorax-ST Cabinets
Page :40
Page :41
Page :42
Page :43
Page :44
42
inorax-ST Cabinets
Components of inorax-ST
1- Top Cover
2 - Bottom Cover
3 - Vertical Proles
4 - 19 Mounting Rails
5 - Side Support Rails
6 - Side Panel
7 - Front Door Options
8 - Rear Door Options
9 - Adjustable Feet
10 - Plinth
11 - Castor
5
4
2
7
11
6
10
9
1
3
8
43
inorax-ST Cabinets
Material
Material
Material
Material
Finish
Finish
Finish
Finish
Color
Color
Color
Color
1.5 mm Steel
1.5 mm Steel
1.5 mm Steel
2 mm Steel
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Zinc-Plated
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)
Metal Grey
Components of inorax-ST
600
600
600
600
600
800
800
800
800
600
600
600
600
600
800
800
800
800
16U
22U
26U
32U
36U
39U
42U
47U
16U
22U
26U
32U
36U
39U
42U
47U
600
800
1000
1100
1200
800
1000
1100
1200
600
800
1000
1100
1200
800
1000
1100
1200
48,5
48,5
48,5
48.5
48,5
48.5
48,5
48.5
33
33
33
33
33
33
33
33
57
57
57
57
57
57
57
57
52
52
52
52
52
52
52
52
10,79
12,70
14,62
15,47
16,42
16,76
19,62
20,95
22,39
11,16
13,07
14,99
15,94
16,90
17,17
20,04
21,47
22,91
1,36
1,84
2,17
2,65
2,97
3,21
3,46
3,86
0,96
1,29
1,52
1,85
2,08
2,25
2,42
2,70
154
154
154
154
154
154
154
154
154
154
154
154
154
154
154
154
154
154
754
1021
1199
1465
1643
1777
1910
2132
753
1020
1198
1464
1642
1776
1909
2131
CSZ-X-YY660-0401
CSZ-X-YY680-0401
CSZ-X-YY600-0401
CSZ-X-YY610-0401
CSZ-X-YY620-0401
CSZ-X-YY880-0401
CSZ-X-YY800-0401
CSZ-X-YY810-0401
CSZ-X-YY820-0401
CSZ-X-YY660-0403
CSZ-X-YY680-0403
CSZ-X-YY600-0403
CSZ-X-YY610-0403
CSZ-X-YY620-0403
CSZ-X-YY880-0403
CSZ-X-YY800-0403
CSZ-X-YY810-0403
CSZ-X-YY820-0403
CSZ-X-16YY0-0300
CSZ-X-22YY0-0300
CSZ-X-26YY0-0300
CSZ-X-32YY0-0300
CSZ-X-36YY0-0300
CSZ-X-39YY0-0300
CSZ-X-42YY0-0300
CSZ-X-47YY0-0300
CSZ-0-16YY0-0600
CSZ-0-22YY0-0600
CSZ-0-26YY0-0600
CSZ-0-32YY0-0600
CSZ-0-36YY0-0600
CSZ-0-39YY0-0600
CSZ-0-42YY0-0600
CSZ-0-47YY0-0600
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
W (mm)
W (mm)
H (U)
H (U)
D (mm)
D (mm)
W (mm)
W (mm)
Weight kg
Weight kg
Weight kg
Weight kg
H (mm)
H (mm)
D (mm)
D (mm)
H (mm)
H (mm)
Part No
Part No
Part No
Part No
Top Cover
Bottom Cover
Vertical Proles
19 Mounting Rails
44
inorax-ST Cabinets
Material
Material
Finish
Finish
Color
Color
1.5 mm Steel
1.5 mm Steel
Electrostatic Powder Paint
Electrostatic Powder Paint
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)
Side Panel
Rear Metal Solid Panel
600
600
800
600
800
1000
600
800
600
800
1000
1200
800
1000
600
800
1000
1100
1200
600
800
1000
1100
1200
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
23
23
23
23
23
23
23
23
23
23
23
23
23
23
600
600
800
600
800
1000
600
800
600
800
1000
1200
800
1000
600
800
1000
1100
1200
600
800
1000
1100
1200
5.11
6,76
8,79
7,86
10,22
9,5
12,37
10,6
13,80
14,88
12,25
15,95
13,62
17,74
749
1016
1016
1194
1194
1194
1460
1460
1638
1638
1638
1638
1772
1772
1905
1905
1905
1905
1905
2127
2127
2127
2127
2127
752
1018
1018
1196
1196
1463
1463
1641
1641
1774
1907
1907
2130
2130
600
600
800
600
800
600
800
600
800
800
600
800
600
800
16U
22U
22U
26U
26U
26U
32U
32U
36U
36U
36U
36U
39U
39U
42U
42U
42U
42U
42U
47U
47U
47U
47U
47U
16U
22U
22U
26U
26U
32U
32U
36U
36U
39U
42U
42U
47U
47U
CSZ-X-16Y60-0501
CSZ-X-22Y60-0501
CSZ-X-22Y80-0501
CSZ-X-26Y60-0501
CSZ-X-26Y80-0501
CSZ-X-26Y00-0501
CSZ-X-32Y60-0501
CSZ-X-32Y80-0501
CSZ-X-36Y60-0501
CSZ-X-36Y80-0501
CSZ-X-36Y00-0501
CSZ-X-36Y20-0501
CSZ-X-39Y80-0501
CSZ-X-39Y00-0501
CSZ-X-42Y60-0501
CSZ-X-42Y80-0501
CSZ-X-42Y00-0501
CSZ-X-42Y10-0501
CSZ-X-42Y20-0501
CSZ-X-47Y60-0501
CSZ-X-47Y80-0501
CSZ-X-47Y00-0501
CSZ-X-47Y10-0501
CSZ-X-47Y20-0501
CSZ-X-166Y0-0901
CSZ-X-226Y0-0901
CSZ-X-228Y0-0901
CSZ-X-266Y0-0901
CSZ-X-268Y0-0901
CSZ-X-326Y0-0901
CSZ-X-328Y0-0901
CSZ-X-366Y0-0901
CSZ-X-368Y0-0901
CSZ-X-398Y0-0901
CSZ-X-426Y0-0901
CSZ-X-428Y0-0901
CSZ-X-476Y0-0901
CSZ-X-478Y0-0901
W (mm)
W (mm)
D (mm)
D (mm)
Weight kg
Weight kg
H (mm)
H (mm)
H (U)
H (U)
Part No
Part No
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)



H
W
D



H
W
D
Material Finish
Color
2 mm Steel Zinc-Plated
Metal Grey
600
600
600
600
600
800
800
800
800
600
800
1000
1100
1200
800
1000
1100
1200
0,75
0,80
0,85
0,87
0,90
0,85
0,92
0,97
1,0 2
CSZ-0-YY660-0700
CSZ-0-YY680-0700
CSZ-0-YY600-0700
CSZ-0-YY610-0700
CSZ-0-YY620-0700
CSZ-0-YY880-0700
CSZ-0-YY800-0700
CSZ-0-YY810-0700
CSZ-0-YY820-0700
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
Cabinet W (mm) Cabinet D (mm) Weight kg Part No
Side Support Rails
45
inorax-ST Cabinets
Material
Material
Material
Material
Finish
Finish
Finish
Finish
Perforation Rate
Perforation Rate
Color
Color
Color
Color
1.2 mm Steel
1.2 mm Steel
1.2 mm Steel
1.2 mm Steel
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
67%
67%
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)
Metal Solid Door
Glass Door
Perforated Flat Door
Double Perforated Door
600
600
800
600
800
600
800
600
800
800
600
800
600
800
600
600
800
600
800
600
800
600
800
800
600
800
600
800
600
600
800
600
800
600
800
600
600
800
600
800
600
800
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
6,87
8,94
11,26
10,32
12,97
12,39
15,54
13,77
17,26
18,54
15,84
19,83
17,56
21,97
5,53
7,42
9,77
8,68
11,42
10,56
13,9
11,82
15,55
16,79
13,7
18,02
15,27
20,09
7,81
10,15
14,02
11,80
15,17
12,97
16,69
11,99
15,70
21,19
18,16
22,83
20,01
25,16
749
1016
1016
1194
1194
1460
1460
1638
1638
1772
1905
1905
2127
2127
749
1016
1016
1194
1194
1460
1460
1638
1638
1772
1905
1905
2127
2127
1194
1638
1772
1905
1905
2127
2127
1194
1638
1772
1905
1905
2127
2127
16U
22U
22U
26U
26U
32U
32U
36U
36U
39U
42U
42U
47U
47U
16U
22U
22U
26U
26U
32U
32U
36U
36U
39U
42U
42U
47U
47U
26U
36U
39U
42U
42U
47U
47U
26U
36U
39U
42U
42U
47U
47U
CSZ-X-166Y0-0902
CSZ-X-226Y0-0902
CSZ-X-228Y0-0902
CSZ-X-266Y0-0902
CSZ-X-268Y0-0902
CSZ-X-326Y0-0902
CSZ-X-328Y0-0902
CSZ-X-366Y0-0902
CSZ-X-368Y0-0902
CSZ-X-398Y0-0902
CSZ-X-426Y0-0902
CSZ-X-428Y0-0902
CSZ-X-476Y0-0902
CSZ-X-478Y0-0902
CSZ-X-166Y0-0903
CSZ-X-226Y0-0903
CSZ-X-228Y0-0903
CSZ-X-266Y0-0903
CSZ-X-268Y0-0903
CSZ-X-326Y0-0903
CSZ-X-328Y0-0903
CSZ-X-366Y0-0903
CSZ-X-368Y0-0903
CSZ-X-398Y0-0903
CSZ-X-426Y0-0903
CSZ-X-428Y0-0903
CSZ-X-476Y0-0903
CSZ-X-478Y0-0903
CSZ-X-266Y0-0904
CSZ-X-366Y0-0904
CSZ-X-398Y0-0904
CSZ-X-426Y0-0904
CSZ-X-428Y0-0904
CSZ-X-476Y0-0904
CSZ-X-478Y0-0904
CSZ-X-266Y0-0908
CSZ-X-366Y0-0908
CSZ-X-398Y0-0908
CSZ-X-426Y0-0908
CSZ-X-428Y0-0908
CSZ-X-476Y0-0908
CSZ-X-478Y0-0908
W (mm)
W (mm)
W (mm)
W (mm)
D (mm)
D (mm)
D (mm)
D (mm)
Weight kg
Weight kg
Weight kg
Weight kg
H (mm)
H (mm)
H (mm)
H (mm)
H (U)
H (U)
H (U)
H (U)
Part No
Part No
Part No
Part No
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)



H
W
D



H
W
D



H
W
D



H
W
D
46
inorax-ST Cabinets
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
High Perforation Rated Flat Door
High Perforation Rated Double Door
Rear Metal Panel with Cable Entry
Adjustable Cable Entry Panel with EPDM Gasket
600
600
800
600
800
600
800
600
600
800
600
800
600
800
600
800
600
800
600
800
600
800
350
22
22
22
22
22
22
22
22
22
22
22
22
22
22
23
23
23
23
23
23
23
23
152
7,51
9,85
13,72
11,50
14,87
12,67
16,39
11,69
15,40
20,89
17,86
22,53
19,71
24,86
0,97
1,35
1,24
1,71
1,52
2,06
1,79
2,42
0,53
1194
1638
1772
1905
1905
2127
2127
1194
1638
1772
1905
1905
2127
2127
133
133
178
178
222
222
267
267
20
26U
36U
39U
42U
42U
47U
47U
26U
36U
39U
42U
42U
47U
47U
3U
3U
4U
4U
5U
5U
6U
6U
CSZ-X-266Y0-0909
CSZ-X-366Y0-0909
CSZ-X-398Y0-0909
CSZ-X-426Y0-0909
CSZ-X-428Y0-0909
CSZ-X-476Y0-0909
CSZ-X-478Y0-0909
CSZ-X-266Y0-0911
CSZ-X-366Y0-0911
CSZ-X-398Y0-0911
CSZ-X-426Y0-0911
CSZ-X-428Y0-0911
CSZ-X-476Y0-0911
CSZ-X-478Y0-0911
CSZ-X-036Y0-0915
CSZ-X-038Y0-0915
CSZ-X-046Y0-0915
CSZ-X-048Y0-0915
CSZ-X-056Y0-0915
CSZ-X-058Y0-0915
CSZ-X-066Y0-0915
CSZ-X-068Y0-0915
CSZ-X-YYYY0-0803
W (mm)
W (mm)
W (mm)
W (mm)
D (mm)
D (mm)
D (mm)
D (mm)
Weight kg
Weight kg
Weight kg
Weight kg
H (mm)
H (mm)
H (mm)
H (mm)
H (U)
H (U)
H (U)
Part No
Part No
Part No
Part No
Material
Material
Material
Material
Perforation Rate
Perforation Rate
Finish
Finish
Finish
Finish
Color
Color
Color
Color
1.2 mm Steel
1.2 mm Steel
1.5 mm Steel
1.2 mm Steel
80%
80%
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)
RAL 7035 (Light Grey) and RAL 9005 (Black)


H
W
D


H
W
D
47
inorax-ST Cabinets
Material
Material
Material
Material
Material
Material
Material
Packaging
Packaging
Packaging
Packaging
Packaging
Packaging
Packaging
Finish
Finish
Part No
Part No
Part No
Part No
Part No
Steel and Plastic ABS
Steel and Plastic ABS
Polyamide
Polyamide
Polyamide
Zinc
Zinc
4 pcs in a box
2 pcs with stopper and 2 pcs without Stopper in a box
1 pc in a box
1 pc in a box
1 pc in a box
1 pc in a box
1 pc in a box
Zinc Plated
Zinc Plated
CPZ-0-YYYY0-1005
CPZ-0-YYYY0-1003
CPZ-0-YYYY0-1004
CPZ-0-YYYY0-1001
CPZ-0-YYYY0-1002
Adjustable Feet Castor Set
Multi Point Lock for Double Doors
Single Point Lock
Multi Point Lock for Single Perforated Door
0.35
0.77
600 kg / piece
250 kg / piece
CCA-0-7014
CCA-0-7015
Set Weight kg
Set Weight kg
Maximum Static Load
Maximum Static Load
Part No
Part No
Material
P k i
Cylindrical Lock for Side Panel
Cylindrical Lock for Rear Metal Solid Panel
12
6
0
1
0
2
2
9
2
47
12 23 12
85
12
55
47
38
55
48
norax AL-45
Automatical Door
Opening System
When temperature increases
dramaticly or fire occurs inside
the cabinet the doors are
automaticly opened
More security is provided
by magnetic lock system
supported by electronical key pad
IP Protection
Gasket at doors and joining points
CPS-X-2660A
CPS-X-2662A
CPS-X-3660A
CPS-X-3662A
CPS-X-3980A
Height
U
Outer Width
(W) mm
Outer Depth
(D) mm
Outer Height
(H) mm
Inner Height
(h1) mm
Inner Width
(w1) mm
Inner Depth
(d1) mm
19 Rails Adjustable
Depth Range (c)
Weight
kg
Part No
Order Information
More security is provided
y magnetic lock system
upported by electronical key pad
When temperature increases
dramaticly or fire occurs inside
the cabinet the doors are
Electronic and
Magnetic
Lock System
Technical Features
Material
Color
Compliance
Packaging
Maximum Static Load
Finish
Frame ; Anodized aluminum extrusion profiles
Other parts : 1,2 and 2 mm steel
RAL 7035 or RAL 9005
RoHS, UL Certified
Assembled or unassembled
Up to 1500 kg. (in 600x1000 mm)
Frame, doors, side panels, top and bottom
covers, Electrostatic Powder Paint, 19 mounting
rails: Zinc-plated
Exceptional aesthetic design perfect for high-profile applications and major installations
Constructed of anodized extruded aluminum
Maximum durability and strength along with the benefits of lightweight construction
42U
42U
42U
42U
42U
600
600
600
800
800
600
800
1000
800
1000
2033
2033
2033
2033
2033
1898
1898
1898
1898
1898
503
503
503
703
703
550
750
950
750
950
129-429
129-629
129-829
129-629
129-829
86,56
99,14
104,88
116,18
121,05
49
inorax-AL High End Server Rack Cabinet
Technical Features
Material
Color
Compliance
Packaging
Maximum Static Load
Finish
New enginered and aesthetic design perfect for high-air inlet in
major applications
Constructed of anodized extruded aluminum
Maximum durability and strength along with the benefits of
lightweight construction
Ultimate cable management capabilities with modular vertical
type and roof type cable organisers
More secure with special locking system
Frame ; Anodized aluminum extrusion profiles
Other parts : 1,2 and 2 mm steel
RAL 7035 or RAL 9005
RoHS, UL Certified
Assembled or unassembled
Up to 1500 kg. (in 600x1000 mm)
Frame, doors, side panels, top and bottom
covers, Electrostatic Powder Paint, 19 mounting
rails: Zinc-plated
Standard Configuration:
Perforated curved front door, Free Air Ratio (FAR): 82%
Perforated double rear doors, Free Air Ratio (FAR): 82%
Front & rear doors with swing handle Multi point-espagnolette
Split side panels with special locks
Internal top sheet with 3 cable entry and fan cut-outs
Roof type cable channels
Modular adjustable vertical cable organizer
2 Pairs of depth adjustable heavy duty 19 Mounting Rails
2 Pairs of Adjustable Feet and castor
Color RAL 7035 or RAL 9005
RoHS compliant, UL and Gost-R Certificated
42U
42U
42U
42U
47U
47U
47U
47U
600
600
800
800
600
600
800
800
1000
1200
1000
1200
1000
1200
1000
1200
2033
2033
2033
2033
2255
2255
2255
2255
1898
1898
1898
1898
2120
2120
2120
2120
503
503
703
703
503
503
703
703
950
1150
950
1150
950
1150
950
1150
129 - 829
129 - 1029
129 - 829
129 -1029
129 - 829
129 -1029
129 - 829
129 -1029
106,48
124,82
117,28
135,40
116,18
133,97
126,71
144,31
Height
U
Outer Width
(W) mm
Outer Depth
(D) mm
Outer Height
(H) mm
Inner Height
(h1) mm
Inner Width
(w1) mm
Inner Depth
(d1) mm
19 Rails Adjustable
Depth Range (c)
Weight
kg
Order Information
H
d1 c
W
D
w1
h1
82%
Perforated Door
50
Frame ; Anodized aluminum extrusion proles
Other parts : 1,2 and 2 mm steel
Doors, side panels, top and bottom covers: Electrostatic Powder
Paint, 19 mounting rails: Zinc-plated
Seismic Rack Cabinet
Canovate seismic cabinets are designed and manufactured according to
structural performance criteria set by Bell Core NEBS requirements for in-
stallation in Earthquake Risk Zone 4 areas. Most of the accessories can be
mounted within seismic cabinets. Use of a oor anchor kit is highly recom-
mended. This Cabinet Provides easy access to equipment via a removable
roof, sides and front/rear doors
Technical Features
Aluminum Frame Structure with 2000kg carrying capacity
Steel reinforced cross-bars in each side of the cabinet including top and
bottom
Chassis is designed to bolt direct into oor with seismic rated fasteners
Perforated front and rear doors
Solid Side Panels
Internal top sheet
2 Pairs of depth adjustable 19 Mounting Rails
2 Pairs of Adjustable Feet
Front Door with Swinghandle Multi point-Espagnolette
Zone 4, UL and Gost-R Certicated, RoHS and TS EN 61587-1 compliant
Material
Color
Maximum Static Load
Finish
Up to 2000 kg.
RAL 7035 or RAL 9005
Standard Conguration:
Related Accessories Rack Monitoring System
Power Distribution Units
Integral Console
Stabilizator for raised oor
Stabilizator for ceiling
42U
42U
42U
42U
42U
600
600
800
800
800
1000
1200
800
1000
1200
2033
2033
2033
2033
2033
1898
1898
1898
1898
1898
503
503
703
703
703
950
1150
750
950
1150
129-829
129-1029
129-629
129-829
129-1029
CPB-X-4260A
CPB-X-4262A
CPB-X-4288A
CPB-X-4280A
CPB-X-4282A
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
Height
U
Outer Width
(W) mm
Outer Depth
(D) mm
Outer Height
(H) mm
Inner Height
(h1) mm
Inner Width
(w1) mm
Inner Depth
(d1) mm
19 Rails Adjustable
Depth Range (c)
Part No
Order Information
Adj t bl P t N
H
W
D
h1
d1
c
w1
51
Bottom View
Top View
300
600
CSE-X-4763A1
CSE-X-4766A1
CSE-X-4763A3
CSE-X-4766A3
CSE-X-4763A4
CSE-X-4766A4
CSE-X-4763A5
CSE-X-4766A5
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
Depth mm Without Front Door
With Fully Perforated
Front Door
With Fully Perforated
Double Front Door
Steel
Frame
Inner Depth
284 mm
300 mm
600 mm
Order Information
Compliances RoHS, UL Certied
1,2 mm steel
Doors, side panels, top and bottom covers: Electrostatic
Powder Paint, ETSI mounting rails: Zinc-plated
ETSI Rack
Canovate ETSI racks are designed to meet the standards of European
Telecommunication Standards Institute (ETSI) which denes cabinets for
Telecom use based on metric norm. ETSI racks are used by xed line and
GSM operators to store Alcatel, Cisco etc switches for the backbone. Our
ETSI racks have a special lock that ensures 300mm depth criteria, which is
a vital factor to choose the right ETSI rack.
Technical Features
Dimensions
Height: 2200 mm
Depth: 600 mm
Width: 300mm or 600 mm
The latch release side panels can either be opened or removed for
cabling access.
Cable entry access panels at top and bottom
Cabinets can be bayed together side by side or back to back
Versatile cable managament facilities
Easily customized to individual requirements
All-Around accessilibility
Material
Color
Maximum Static Load
Finish
Up to 600 kg.
RAL 7035 or RAL 9005
Standard Conguration:
52
Order Information
26 U
42 U
47 U
CSL-X-26YYA1
CSL-X-42YYA1
CSL-X-47YYA1
CSL-X-26YYA2
CSL-X-42YYA2
CSL-X-47YYA2
CSL-X-26YYA3
CSL-X-42YYA3
CSL-X-47YYA3
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
Height U
Single Frame
Open Rack
Doube Frame
Open Rack
Fixed Frame
Open Rack
Single Frame Double Frame Double Frame
1,5 mm steel
Frame: Electrostatic Powder Paint
19 Open Frame Racks
Canovate Open Frame Racks are designed for a professional cable man-
agement in protected datacenter rooms. Special cabeling sections on the
left and right side provide a exible and proper cable management
Technical Features
Superior design for complex cable management
19 universal hole pattern for front and side mounting of equipment
Easy cable management through large cut outs on the frame and cable conducts
by cable clamps can be mountable on all faces
Base openings ready for individual positioning of the frame
Base equipped with feet (standard) or castors (optional)
Flat pack delivery available
Material
Color
Maximum Static Load
Finish
Up to 600 kg.
RAL 7035 or RAL 9005
Standard Conguration:
53
Single
Single
Double
Double
42U
47U
42U
47U
2040
2265
2040
2265
920
920
1720
1720
537
573
573
573
CSP-X-42YYA1
CSP-X-47YYA1
CSP-X-42YYA2
CSP-X-47YYA2
Frame Type Height U Height mm Width mm Depth mm Part No
Order Information
Material
Color
Maximum Static Load
Dimensions
Finish
Sheet steel enclosure frame
Plates : 1,5 mm, Door : 2,0 mm, Mounting Plate :3,0 mm
Up to 500 kg.
Width : 600 mm Height : 2000 mm Depth : 600 mm
Electrostatic Powder Paint
Enclosure frame : Dipcoat primed Door, roof and rear panel :
Dipcoat-Primed, Powder-coated in textured RAL 7035 on the outside
Mounting plate and gland plates: Zinc-Plated
RAL 7035
Two stage front door
1,5 mm steel
Patch Rack
Industrial Cabinet
As a result of demand in bandwith escalation, managing data cabling
particularly cable performance has become critical today. With the in-
troduction of CAT 5 cabling, the best practice is to maintain the optimal
bend radius and limit physical impact on the cable, preventing stretching,
twisting and snagging. Any cable deformation will have severe effects on
the network performance. Canovates Patch Rack solves these issues by
forming the fundamental frame for managing and distribution of the data
cabling within a datacenter. Patch Rack is a modular open frame providing
outstanding allround accessibility, mounting for 19-inch patch panels and
dedicated cable channels at the front and rear on each side of the frame
Canovate Industrial Cabinets are designed to meet the highest criterias
required for electrical and automation control applications. Cabinets have
a steel frame based construction and gasketing to ensure IP 55 protection
for electrical equipments inside the rack.
Technical Features
Technical Features
42U and 47U high, with 19, mountings
Optimized for Cat 5E, Cat 6, Cat 7, 10Gb
Robust framework rated at 500 kg
Vertical cable channels tted to both sides of the PATCHRack
Set of front-mounting cable across the front face of the enclosure
All standard president cable accessories t the PATCHRack
Front covers on either side hinge both ways, or can be removed
Steel frame structure with 900 kg carrying capacity
Two stage front door structure for user and administrator access
Swinghandle single point-espagnolette lock on the administrator door
Solid side panels with locks
Solid rear panel
Depth-adjustable mounting plate with cross channels
External top cover with cable access and ventilation
100 mm ventilated plinth
2 Pairs of adjustable feet
RoHS compliant, UL and GOST-R Certicated
Approvals : VDE 6312 G
Protection Category :IP 55
Material
Color
Maximum Static Load
Finish
Up to 600 kg.
RAL 7035 or RAL 9005
Standard Conguration:
Standard Conguration:
54
H
W
D
h1
d1
K
c
w1
24U
42U
600
600
1000
1000
1155
2033
1020
2095
503
503
950
950
235
235
129-729
129-729
CPJ-X-2460A
CPJ-X-4260A
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
Height
U
Outer Width
(W) mm
Outer Depth
(D) mm
Outer Height
(H) mm
Inner Height
(h1) mm
Inner Width
(w1) mm
Inner Depth
(d1) mm
19 Rails Adjustable
Depth Range (c)
Depth of Air
Condition (K)
Part No
Order Information
Frame ; Anodized aluminum extrusion proles.
Other parts : 1,2 and 2 mm steel
Doors, side panels, top and bottom covers: Electrostatic Powder
Paint, 19 mounting rails: Zinc-plated
Thermal Cabinet-IP54
Canovate Thermal Cabinet is an ideal solution for electrical or IT applica-
tions with a high load of internaly generated heat. The solution is based on
the aluminum frame cabinet and the rack is IP54 protected to increase the
cooling efciency of the AC unit installed on the front door.
Technical Features
Aluminum Frame Structure with 1500 kg carrying capacity
Solid front door with build in AC unit
Solid Side Panels
Solid Rear Panel
External top sheet
2 Pairs of depth adjustable 19 Mounting Rails
2 Pairs of Adjustable Feet
Front Door with Swinghandle Multi point-Espagnolette
IP54 protected with special gasketing
RoHS compliant, UL and Gost-R Certicated
Optional Double Skin
Material
Color
Maximum Static Load
Finish
Compliance
Packaging
Up to 2000 kg.
RAL 7035 or RAL 9005
RoHS, UL Certied
Assembled or unassembled
Standard Conguration:
Related Accessories Rack Monitoring System
Power Distribution Units
Integral Console
Packaging Options
Flatpack Cabinet Packaging
Assembled Packaging
Saves %60 warehouse space and transport cost
Damage-free transportation
Ready for installation
6 pieces on a pallette
Full cover cardboard
Steel strip secured by polypropylene straps
Environment friendly (100% recycled) packaging material
Damage-free transport
Ready for installation
Fixed on the pallet with metal brackets
Full cover cardboard
Steel strip secured by polypropylene straps
Environment friendly (100% recycled) packaging material
55
Wallmount Cabinets
Wallmount Cabinets
Canovate Wallmount cabinets are designed to ensure professional cable management and easy acesss inside the cabinet for installers. We
are offering a wide range of wallmount enclosures for every type of application to be required in small and medium scale networks.
56
Wallmount Cabinets
6
6
9
9
12
12
15
15
18
18
21
21
6
6
9
9
12
12
15
15
18
18
21
21
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
400
560
400
560
400
560
400
560
400
560
400
560
400
560
400
560
400
560
400
560
400
560
400
560
366
366
488
488
621
621
755
755
888
888
1022
1022
366
366
488
488
621
621
755
755
888
888
1022
1022
266
266
408
408
541
541
674
674
808
808
942
942
266
266
408
408
541
541
674
674
808
808
942
942
510
510
510
510
510
510
510
510
510
510
510
510
510
510
510
510
510
510
510
510
510
510
510
510
360
520
360
520
360
520
360
520
360
520
360
520
360
520
360
520
360
520
360
520
360
520
360
520
21,36
24,26
24,62
27,82
28,01
31,65
31,4
35,49
34,81
39,33
38,2
43,16
22,25
25,27
25,6
28,93
29,13
32,92
32,66
36,91
36,2
40,9
39,73
44,89
110-305
110-465
110-305
110-465
110-305
110-465
110-305
110-465
110-305
110-465
110-305
110-465
110-305
110-465
110-305
110-465
110-305
110-465
110-305
110-465
110-305
110-465
110-305
110-465
WSF-X-0664A
WSF-X-0665A
WSF-X-0964A
WSF-X-0965A
WSF-X-1264A
WSF-X-1265A
WSF-X-1564A
WSF-X-1565A
WSF-X-1864A
WSF-X-1865A
WSF-X-2164A
WSF-X-2165A
WSO-X-0664A
WSO-X-0665A
WSO-X-0964A
WSO-X-0965A
WSO-X-1264A
WSO-X-1265A
WSO-X-1564A
WSO-X-1565A
WSO-X-1864A
WSO-X-1865A
WSO-X-2164A
WSO-X-2165A
Height
U
Height
U
Outer Width
(W) mm
Outer Width
(W) mm
Outer Depth
(D) mm
Outer Depth
(D) mm
Outer Height
(H) mm
Outer Height
(H) mm
Inner Height
(h1) mm
Inner Height
(h1) mm
Inner Width
(w1) mm
Inner Width
(w1) mm
Inner Depth
(d1) mm
Inner Depth
(d1) mm
19 Rails Adjustable
Depth Range (c)
19 Rails Adjustable
Depth Range (c)
Weight
kg
Weight
kg
Part No
Part No
Order Information
Order Information
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
d1
c
w1
W
D
H
h1
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
d1 c
w1
W
D
H
h1
1,5 mm steel
1,2 mm steel
Electrostatic Powder Paint
Electrostatic Powder Paint
Single Wallmount Cabinet with Fixed Side Panels
Single Wallmount Cabinet with Openable Side Panels From Outside
Technical Features
Technical Features
Steel frame
Glass door with cylindrical lock
Fixed side panels
1 Pair of heavy duty 19 mounting rails
Color RAL 7035 , RAL 9005
RoHS compliant, UL and Gost-R Certicated
Steel frame
Glass door with cylindrical lock
Openable side panels with cylindrical lock
1 Pair of heavy duty 19 mounting rails
RoHS compliant, UL and Gost-R Certicated
Flatpack option available
Color RAL 7035 or RAL 9005
Material
Material
Color
Color
Maximum Static Load
Maximum Static Load
Finish
Finish
Up to 100 kg.
Up to 100 kg.
RAL 7035 or RAL 9005
RAL 7035 or RAL 9005
Standard Conguration:
Standard Conguration:
57
Wallmount Cabinets
9
9
12
12
15
15
6
6
9
9
12
12
15
15
18
18
21
21
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
400
560
400
560
400
560
300+150
500+150
300+150
500+150
300+150
500+150
300+150
500+150
300+150
500+150
300+150
500+150
488
488
621
621
755
755
366
366
500
500
632
632
766
766
900
900
1034
1034
408
408
541
541
674
674
266
266
400
400
532
532
666
666
800
800
934
934
510
510
510
510
510
510
530
530
530
530
530
530
530
530
530
530
530
530
360
520
360
520
360
520
260+120
460+120
260+120
460+120
260+120
460+120
260+120
460+120
260+120
460+120
260+120
460+120
25,6
28,93
29,13
32,92
32,66
36,91
20,23
22,4
29,93
32,44
38,67
42,87
46,34
52,61
55,46
62,9
64,67
72,43
110-305
110-465
110-305
110-465
110-305
110-405
110-205
110-405
110-205
110-405
110-205
110-405
110-205
110-405
110-205
110-405
110-205
110-405
WSN-X-0964A
WSN-X-0965A
WSN-X-1264A
WSN-X-1265A
WSN-X-1564A
WSN-X-1565A
WKD-X-0664A
WKD-X-0666A
WKD-X-0964A
WKD-X-0966A
WKD-X-1264A
WKD-X-1266A
WKD-X-1564A
WKD-X-1566A
WKD-X-1864A
WKD-X-1866A
WKD-X-2164A
WKD-X-2166A
Height
U
Height
U
Outer Width
(W) mm
Outer Width
(W) mm
Outer Depth
(D) mm
Outer Depth
(D) mm
Outer Height
(H) mm
Outer Height
(H) mm
Inner Height
(h1) mm
Inner Height
(h1) mm
Inner Width
(w1) mm
Inner Width
(w1) mm
Inner Depth
(d1) mm
Inner Depth
(d1) mm
19 Rails Adjustable
Depth Range (c)
19 Rails Adjustable
Depth Range (c)
Weight
kg
Weight
kg
Part No
Part No
Order Information
Order Information
Single Wallmount Cabinet with Openable Side Panels From Inside
Double Section Wallmount Cabinet
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
Inside Lock System
d1 c
w1 W
D
H
h1
d1 w1
h1
W=600
D
1,5 mm steel
1,5 mm steel
Electrostatic Powder Paint
Electrostatic Powder Paint
Technical Features
Technical Features
Steel frame
Glass door with cylindrical lock
Openable side panels from inside for security
1 Pair of heavy duty 19 mounting rails
Flatpack option available
RoHS compliant, UL and Gost-R Certicated
Steel frame
Glass door with cylindrical lock
Accessible from rear side with double hinged
design
1 Pair of heavy duty 19 Mounting Rails
RoHS compliant, UL and Gost-R Certicated
Material
Material
Color
Color
Maximum Static Load
Maximum Static Load
Finish
Finish
Up to 100 kg.
Up to 100 kg.
RAL 7035 or RAL 9005
RAL 7035 or RAL 9005
Standard Conguration:
Standard Conguration:
58
Wallmount Cabinets
h1
w1
d1
W
D
H
D
w1
h1
W= 600
H
12
15
24
600
600
600
150
150
125
599
733
1133
534
667
1067
525
525
525
113
113
85
12,3
14,6
20,7
WKF-X-1261A
WKF-X-1561A
WKF-X-2461A
Height
U
Outer Width
(W) mm
Outer Depth
(D) mm
Outer Height
(H) mm
Inner Height
(h1) mm
Inner Width
(w1) mm
Inner Depth
(d1) mm
Weight
kg
Part No
Order Information
Slim Line Wallmount Cabinet
Single Wallmount Cabinet
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
6
9
12
15
18
21
600
600
600
600
600
600
500
500
500
500
500
500
366
500
632
766
900
1034
266
400
532
666
800
934
530
530
530
530
530
530
450
450
450
450
450
450
21,34
25,68
28,46
32,86
36,59
42,6
110-405
110-405
110-405
110-405
110-405
110-405
WKF-X-0665A
WKF-X-0965A
WKF-X-1265A
WKF-X-1565A
WKF-X-1865A
WKF-X-2165A
Height
U
Outer Width
(W) mm
Outer Depth
(D) mm
Outer Height
(H) mm
Inner Height
(h1) mm
Inner Width
(w1) mm
Inner Depth
(d1) mm
19 Rails Adjustable
Depth Range (c)
Weight
kg
Part No
Order Information
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
1,2 mm steel
1,5 mm steel
Electrostatic Powder Paint
Electrostatic Powder Paint
Technical Features
Technical Features
Steel frame
Glass door with cylindrical lock
Slim line solution for restricted areas
1 Pair of heavy duty 19 mounting rails
RoHS compliant, UL and Gost-R certicated
Steel frame monoblock chassis
Glass door with cylindrical lock
1 Pair of heavy duty 19 mounting rails
IP Protection can be applied as an option
RoHS compliant, UL and Gost-R certicated
Material
Material
Color
Color
Maximum Static Load
Maximum Static Load
Finish
Finish
Up to 75 kg.
Up to 75 kg.
RAL 7035 or RAL 9005
RAL 7035 or RAL 9005
Standard Conguration:
Standard Conguration:
59
Wallmount Cabinets
6
9
12
6
316
500
500
272
310
450
450
450
350
469
603
277
275
408
543
177
478
478
478
422
422
422
5,89
7,97
10,05
17
WCS-X-0654A
WCS-X-0954A
WCS-X-1254A
WCT-X-0624A
Height
U
Height
U
Outer Width
(W) mm
Outer Width
(W) mm
Outer Depth
(D) mm
Outer Depth
(D) mm
Outer Height
(H) mm
Outer Height
(H) mm
Inner Height
(h1) mm
Inner Height
(h1) mm
Inner Width
(w1) mm
Inner Width
(w1) mm
Inner Depth
(d1) mm
Inner Depth
(d1) mm
Weight
kg
Weight
kg
Part No
Part No
Order Information
Order Information
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
d1
H
w1
W
D
d1 c
w1
W
D
H
h1
19 SOHO Cabinet
10 SOHO Cabinet
1,2 mm steel
1,2 mm steel
Electrostatic Powder Paint
Electrostatic Powder Paint
Technical Features
Technical Features
Steel frame
Glass door with cylindrical lock
1 Pair of heavy duty 19 mounting rails
Flatpack option available
Low cost alternative
RoHS compliant, UL and Gost-R certicated
Steel Frame
Glass door with cylindrical lock
Openable side panels
1 Pair of heavy duty 19 mounting rails
RoHS compliant, UL and Gost-R certicated
Material
Material
Color
Color
Maximum Static Load
Maximum Static Load
Finish
Finish
Up to 50 kg.
Up to 50 kg.
RAL 7035 or RAL 9005
RAL 7035 or RAL 9005
Standard Conguration:
Standard Conguration:
60
Accessories
Accessories
Canovate offers a wide range of accessories to provide the best cable management and installation options for the complex requirements
of IT users. Canovate believes that a proper and safe cabling is a real challenge for the installers and thus we try to offer the best variety to
satisfy all their requirements
61
Accessories
19 Cantilever Shelf
19 Heavy Duty Fixed Shelf
19 Drawer
19 Fixed Shelf
19 Sliding Shelf
Fan Module for Wall Mount Enclosures
Fan Module for inorax-ST series
19 1U Fan Module
Material
Material
Material
Material
Material
Material
Material
Material
Finish
Finish
Finish
Finish
Finish
Finish
Finish
Finish
Maximum Static Load
Maximum Static Load
Maximum Static Load
Maximum Static Load
Maximum Static Load
Air Flow
Air Flow
Air Flow
Noise
Noise
Noise
Operating Voltage
Operating Voltage
Operating Voltage
Packaging
Packaging
Packaging
Packaging
Packaging
Packaging
Packaging
Packaging
Fan Speed
Fan Speed
Fan Speed
Standards
Standards
Standards
1,5 mm Steel
1,5 mm Steel
1,5 mm Steel
1,0 mm Steel
1,5 mm Steel
0,8 mm Steel
0,8 mm Steel
1,5 mm Steel
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
15-25 kg
100 kg
35 kg
50 kg
35 kg
95 -115 CFM
95 -115 CFM
95 -115 CFM
44 - 49 dB (A)
44 - 49 dB (A)
44 - 49 dB (A)
AC 220 - 240 Volts 50/60 Hz
AC 220 - 240 Volts 50/60 Hz
AC 220 - 240 Volts 50/60 Hz
Bubble Nylon
One piece in a box
Bubble Nylon
One piece in a box
One piece in a box
One piece in a box
One piece in a box
One piece in a box
2700 - 3100 rpm
2700 - 3100 rpm
2700 - 3100 rpm
Conforms to IEC 297-1
Conforms to IEC 297-1
Conforms to IEC 297-1
Ma ate te i ri l al Ma Maxi x mmu 11 55 mm SStte l el MM t i l M ii 1 5 St l
1U
2U
2U
1U
1U
1U
1U
1U
1U
1U
1U
1U
1U
1U
1U
2U
3U
150
250
400
400
600
800
1000
400
600
800
1000
39
39
47
47
1U
400
600
800
1000
500
500
483
483
483
465
465
465
465
483
483
483
483
135
135
375
375
258
483
483
483
483
483
483
437
437
437
465
465
465
465
435
435
435
435
326
326
363
363
483
1
2
2
4
3
435
435
435
435
435
435
0,84
1,58
2,43
1,22
1,83
2,44
3,05
3,56
1,27
1,80
2,90
3,95
4,19
2,95
3,95
4,95
5,95
6,36
9,54
CCA-X-1001
CCA-X-1002
CCA-X-1003
CCA-X-1004
CCA-X-1005
CCA-X-1006
CCA-X-1007
CCA-X-1012
CCA-X-1013
CCA-X-1014
CCA-X-1015
CWA-X-2001
CWA-X-2002
CSA-X-2001
CSA-X-2002
CCA-X-2001
CCA-X-1008
CCA-X-1009
CCA-X-1010
CCA-X-1011
CCA-X-1016
CCA-X-1017
* X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
H (U) H (U)
H (U)
H (U)
H (U)
D (mm) D (mm)
D (mm)
H (mm)
H (mm)
H (U)
D (mm)
D (mm)
W (mm) W (mm)
W (mm)
D (mm)
D (mm)
D (mm)
W (mm)
W (mm)
Inner W (mm) Inner W (mm)
Inner W (mm)
W (mm)
W (mm)
W (mm)
Number of
Fans
Number of
Fans
Number of
Fans
Inner W (mm)
Inner W (mm)
Weight kg Weight kg
Weight kg
Weight kg
Weight kg
Weight kg
Weight kg
Weight kg
Part No Part No
Part No
Part No
Part No
Part No
Part No
Part No
D H
W
In
n
e
r W
W
D
H
H
D
H
W
INNER W
H W
D H
W
Inner W
D
H W
D
W
H
D
62
Accessories
Plinth with Fixing to The Raised Rloor
19 1U Plastic Blanking Panel
19 Blanking Panels
19 Ventilated Blanking Panels
19 Plastic Cable Organizer
19 Covered Cable Organizer
Cable Hook
Plinth for inorax
Fan Module for inorax-Al Series
Material
Material
Material
Material
Material
Material
Material
Material
Material
Finish
Finish
Finish
Finish
Finish
Finish
Finish
Finish
Air Flow Noise
Operating Voltage
Packaging
Packaging
Packaging
Packaging
Packaging
Packaging
Packaging
Packaging
Packaging Fan Speed
Standards
2 mm Steel
Plastic ABS
1,2 mm Steel
1,2 mm Steel
1,5 mm Steel, Plastic
1,5 mm Steel
Steel
2 mm Steel
1,5 mm Steel
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Zinc Plated
Electrostatic Powder Paint
95 -115 CFM 44 - 49 dB (A)
AC 220 - 240 Volts 50/60 Hz
One piece in a box
One piece in a box
One piece in a box
One piece in a box
One piece in a box
One piece in a box
1 Pc in a Nylon
One piece in a box
One piece in a box 2700 - 3100 rpm
Conforms to IEC 297-1
100
100
100
100
100
100
100
100
100
1U
1U
2U
4U
1U
2U
1U
1U
100
170
90
90
90
90
90
90
90
90
90
600
600
600
600
600
800
800
800
800
6
483
483
483
483
483
483
483
60
60
600
600
600
600
600
800
800
800
800
47
47
47
600
800
1000
1100
1200
800
1000
1100
1200
6
9
9
9
9
9
80
100
80
600
800
1000
1100
1200
800
1000
1100
1200
375
375
510
363
363
363
2
4
6
9,32
10,00
10,56
10,97
11,37
10,69
11,24
11,65
12,10
0,08
0,26
0,46
0,86
0,24
0,42
0,49
0,6
0,09
0,10
5,95
7,10
7,96
8,83
9,71
7,27
8,14
9,01
9,89
3,76
4,81
6,74
CPA-X-3010
CPA-X-3011
CPA-X-3012
CPA-X-3013
CPA-X-3014
CPA-X-3015
CPA-X-3016
CPA-X-3017
CPA-X-3018
CCA-X-4001
CCA-X-4002
CCA-X-4003
CCA-X-4004
CCA-X-4005
CCA-X-4006
CCA-0-5001
CCA-X-5004
CCA-0-5002
CCA-0-5003
CCA-X-3001
CCA-X-3002
CCA-X-3003
CCA-X-3004
CCA-X-3005
CCA-X-3006
CCA-X-3007
CCA-X-3008
CCA-X-3009
CPA-X-2001
CPA-X-2002
CPA-X-2003
H (mm)
H (U)
H (U)
H (U)
H (U)
H (U)
H (mm)
H (mm)
D (mm)
W (mm)
W (mm)
W (mm)
W (mm)
W (mm)
W (mm)
D (mm)
H (mm)
W (mm)
D (mm)
D (mm)
D (mm)
D (mm)
D (mm)
W (mm)
D (mm) W (mm)
Number of
Fans
Weight kg
Weight kg
Weight kg
Weight kg
Weight kg
Weight kg
Weight kg
Weight kg
Weight kg
Part No
Part No
Part No
Part No
Part No
Part No
Part No
Part No
Part No
MM t ii l Fi Fi ii h 2 St l
for Inorax-Al Series
* X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
19 Covered Cable
W
D
H
H
w
H
D
w
H
D
w
H
D
H
W
D
63
Accessories
Vertical Side Cable Organizer Type1
Material Finish
Packaging
1,5 mm Steel Zinc Plated
2 pieces in Bubble Nylon
26U
32U
36U
39U
42U
47U
1246
1510
1686
1820
1950
2170
10
10
10
10
10
10
260
260
260
260
260
260
3,20
3,86
4,36
4,74
5,11
5,74
CCA-0-5011
CCA-0-5012
CCA-0-5013
CCA-0-5014
CCA-0-5015
CCA-0-5016
H (U) H (mm) D (mm) W (mm) Weight kg Part No
Vertical Cable Organizer
19 Cable Entry
19 Cable Entry with Brush
19 1U Light
19 1U Light
Vertical Side Cable Organizer Type2
Modular Adjustable Vertical Cable
Organizer Type1
Modular Adjustable Vertical Cable
Organizer Type2
Material
Material
Material
Material
Material
Material
Material
Material
Finish
Finish
Finish
Finish
Finish
Finish
Finish
Finish
Packaging
Packaging
Packaging
Packaging
Packaging
Power
Power Consumption
Voltage
Voltage
Packaging
Packaging
Packaging
Module Capacity
Module Capacity
Mounting Back Plane
Mounting Back Plane
Module
Module
1,5 mm Steel
1,5 mm Steel
1,5 mm Steel, Brush
1,2 mm Steel
Anodized Aluminum Extrusion
1,5 mm Steel
1,5 mm Steel
1,5 mm Steel
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
2 pieces in a box
One piece in a box
One piece in a box
One piece in a box
One piece in a box
11W
11W
AC 220 - 240 Volts 50/60 Hz
AC 220 - 240 Volts 50/60 Hz
2 pieces in a box
1 piece in a box
1 piece in a box
Max 10 pieces
Max 4 pieces
26U
32U
36U
39U
42U
47U
1U
2U
1U
2U
1U
400
26U
32U
36U
39U
42U
47U
42U
47U
42U
47U
150
690
92
92
92
92
92
92
9
9
10
10
53
15
1246
1510
1686
1820
1950
2170
10
10
10
10
10
10
13
13
10
10
70
5
100
100
100
100
100
100
483
483
483
483
483
24
260
260
260
260
260
260
120
120
123
123
90
55
3,80
4,10
4,70
5,10
5,50
6,20
0,16
0,25
0,2
0,3
0,5
0,25
3,00
3,61
4,01
4,44
4,79
5,38
2,83
3,17
2,15
2,40
0,42
0,50
CCA-X-5005
CCA-X-5006
CCA-X-5007
CCA-X-5008
CCA-X-5009
CCA-X-5010
CCA-X-5029
CCA-X-5030
CCA-X-5031
CCA-X-5032
CCA-X-7001
CCA-0-7025
CCA-X-5017
CCA-X-5018
CCA-X-5019
CCA-X-5020
CCA-X-5021
CCA-X-5022
CCA-X-5023
CCA-X-5024
CCA-X-5026
CCA-X-5027
CCA-X-5025
CCA-X-5028
H (U)
H (U)
H (U)
H (U)
Length (U)
H (U)
H (U)
H (U)
H (mm)
H (mm)
D (mm)
D (mm)
D (mm)
D (mm)
D (mm)
H (mm) D (mm)
D (mm)
D (mm)
D (mm)
D (mm)
W (mm)
W (mm)
W (mm)
W (mm)
W (mm)
W (mm)
W (mm)
W (mm)
W (mm)
W (mm)
Weight kg
Weight kg
Weight kg
Weight kg
Weight kg
Weight kg
Weight kg
Weight kg
Weight kg
Weight kg
Part No
Part No
Part No
Part No
Part No
Part No
Part No
Part No
Part No
Part No
* X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
w
H
D
w
H
D
64
Accessories
Cable Clamp Rail
C-Rail
Baying Kit for inorax-Al Series
Stabilizor for Ceiling
Stabilizor for raised oor
Baying Kit for inorax Series
Chassis Rail
Integral Console + KVM
Material Material
Material
Material
Material
Material
Material
Finish Finish
Finish
Finish
Finish
Packaging Packaging
Packaging
Packaging
Set
Set
Packaging
Technical Specications
1,5 mm Steel 2 mm Steel
Anodized Aluminum Prole
2 mm Galvanized Steel
1,5 mm Steel
3 mm Steel
2 mm Galvanized Steel
Zinc Plated Zinc Plated
Anodization
Zinc Plated
Electrostatic Powder Paint
One piece in a box 2 pieces in a box
One piece in a box
4 pieces in a set
Kit includes 4 pcs vertical proles and 2
pcs ceiling xing proles, bolts
Kit includes 4 or 6 pcs anchor sets
4 pieces in a set
17/19 TFT LCD Display
8/16 Port KVM Switch
On Screen Display
Hot Key Function
Hot Plug Function
Integral console controls comput-
ers and servers inside cabinets or
server room with one LCD moni-
tor, keyboard and mouse. This
prevents unnecessary costs and
saves space.
Sliding rail mount reduces occu-
pied space inside cabinets. 8 or
16 computers can be connected. Daisy chain structure provides 3
level cascade connection and controllability up to 999 computers.
600
800
1000
1200
600
800
1000
1200
10
23
300
600
800
1000
1200
300
300
600
600
600
800
1000
17
17
19
19
64
64
64
64
20
20
20
20
66
86
1,9
1,9
1,9
USB
PS/2
USB
PS/2
15
15
15
15
34
34
34
34
50
52
1000
1000
1000
1000
1000
< 800
> 800
< 800
> 800
4
6
4
6
44,68
67,02
89,36
134,04
3,3
3,3
3,3
CCA-O-8001
CCA-O-8002
CCA-O-8003
CCA-O-8004
0,36
0,48
0,60
0,72
0,30
0,39
0,49
0,59
0,055
0,125
0,47
0,63
0,79
CCA-0-5033
CCA-0-5034
CCA-0-5035
CCA-0-5036
CCA-0-5037
CCA-0-5038
CCA-0-5039
CCA-0-5040
CPA-0-7001
CSA-0-7001
CCA-0-7005
CCA-0-7006
CCA-0-7007
CCA-0-7008
CCA-0-7009
CCA-X-7010
CCA-X-7011
CCA-X-7012
CCA-X-7013
CCA-0-7002
CCA-0-7003
CCA-0-7004
CCA-O-8005
CCA-O-8006
CCA-O-8007
CCA-O-8008
Length (mm)
Length (mm)
H (mm)
H (mm)
Cabinet D (mm)
Raised Floor H
Length (mm)
LCD Panel Size
H (mm)
H (mm)
D (mm)
D (mm)
H (mm)
Connection Type
W (mm)
W (mm)
W (mm)
W (mm)
H (mm)
Cabinet D# of Anchors Set Weight
kg
W (mm)
8 Port
Weight kg
Weight kg
Weight kg
Weight kg
Weight kg
Part No
Part No
Part No
Part No
Part No
Part No
Part No
Part 16 Port
* X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
Material Fin 2 mm Steel
(ETSI)
70
44
2
L
H
W
Cable Clamp for C-Rail
Material
Finish
Packaging
Steel
Zinc Plated
5 Pieces in a box
8 - 12
11 - 18
12 - 23
0,042
0,048
0,054
CCA-0-5041
CCA-0-5042
CCA-0-5043
Cable Diameter mm Weight kg Part No
65
Accessories
Sliding Anti-Swing Stabilizor
Earthing Kit
Earthing Bar
Adjustable Feet
Castor Set
Heavy Duty Castor Set
Material
Material
Material
Finish
Finish
Finish
Packaging
Packaging
Packaging
1,5 mm Steel
Copper
Copper
Electrostatic Powder Paint
PVC Jacket
PVC Jacket
1 piece in a set
One set in a box
One set in a box
90
90
90
90
90
90
90
300
490
600
600
600
800
800
800
800
2,5
2,5
1000
1100
1200
800
1000
1100
1200
9,47
10,50
11,64
11,70
12,63
14,01
15,28
0,08 kg
0,3 kg
CPA-X-3019
CPA-X-3020
CPA-X-3021
CPA-X-3022
CPA-X-3023
CPA-X-3024
CPA-X-3025
CCA-0-7017
CCA-0-7019
H (mm)
Length (mm)
Length (mm)
D (mm)
Cross Section
Cross Section
W (mm) Weight kg
Weight kg
Weight kg
Part No
Part No
Part No
Material
Material
Material
Packaging
Packaging
Packaging
Packaging
Finish
Finish
Finish
Steel and Plastic ABS
Steel and Plastic ABS
Steel and Plastic ABS
4 pcs in a box
4 pcs
2 pcs with stopper and 2 pcs without stopper in a box
2 pcs with stopper and 2 pcs without stopper in a box
Zinc Plated
Zinc Plated
Zinc Plated
0.35
0.77
0.77
600 kg / piece
250 kg / piece
600 kg / piece
CCA-0-7014
CCA-0-7015
CCA-0-7016
Set Weight kg
Set Weight kg
Set Weight kg
Maximum Static Load
Maximum Static Load
Maximum Static Load
Part No
Part No
Part No
92
22
12
47 23 12 12
60
10
12
60
10
22
92
47 12 23 12
92
22
12
47 23 12 12
60
10
12
60
10
22
92
47 12 23 12
85
12
55
47
38
55
Cage Nut & Bolt & Plastic Cup Washer Set
Separator for Bayed Cabinets
Material
Material
Finish
Finish
Diameter
One Set Includes
Steel
1,5 mm Steel
Zinc Plated
Electrostatic Powder Paint
6 mm (M6)
20 pieces of M6x15 Screw, M6 Nut, M6 Polyamid Washer
0,10
1000
1200
1000
1200
1000
1200
1000
1200
20
42U
42U
47U
47U
42U
42U
47U
47U
CCA-0-7018
CSA-X-8001
CSA-X-8002
CSA-X-8003
CSA-X-8004
CPA-X-8001
CPA-X-8002
CPA-X-8003
CPA-X-8004
Set Weight kg
D (mm)
D (mm)
Quantity in a set
H (mm)
H (mm)
Part No
Part No
Part No
For Inorax Series
For Inorax-Al Series
66
Accessories
600
800
125
125
580
735
100
100
1,87
2,75
CPA-X-6010
CPA-X-6011
Cabinet
W(mm)
D (mm) W (mm) H (mm) Weight kg Part No
Data Cable Gate Shield
Data Cable Gate Shield with Double Side Entry
Data Cable Shield with One Side Entry
Material Material
Material
Finish Finish
Finish
Packaging Packaging
Packaging
1,5 mm Steel 1,5 mm Steel
1,5 mm Steel
Electrostatic Powder Paint Electrostatic Powder Paint
Electrostatic Powder Paint
1 pc in a box 1 pc in a box
1 pc in a box
75
275
500
500
125
175
1,50
1,31
CPA-X-6008
CPA-X-6009
D (mm)
D (mm)
W (mm)
W (mm)
H (mm)
H (mm)
Weight kg
Weight kg
Part No
Part No
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
Power Cable Gate
Power Cable Inlet
Power Cable Channel
Data Cable Shield with Double Side Entry
Material
Material
Material
Material
Finish
Finish
Finish
Finish
Packaging
Packaging
Packaging
Packaging
1,5 mm Steel
1,5 mm Steel
1,5 mm Steel
1,5 mm Steel
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
Electrostatic Powder Paint
1 pc in a box
1 pc in a box
1 pc in a box
1 pcin a box
500
600
800
600
800
600
800
275
340
340
340
340
100
100
580
735
580
735
580
735
175
185
185
185
185
125
125
3,15 kg
4,84
6,15
5,03
6,35
1,82
2,31
CPA-X-6001
CPA-X-6002
CPA-X-6003
CPA-X-6004
CPA-X-6005
CPA-X-6006
CPA-X-6007
W (mm)
Cabinet
W(mm)
Cabinet
W(mm)
Cabinet
W(mm)
D (mm)
D (mm)
D (mm)
D (mm)
W (mm)
W (mm)
W (mm)
H (mm)
H (mm)
H (mm)
H (mm)
Weight kg
Weight kg
Weight kg
Weight kg
Part No
Part No
Part No
Part No
Canovate recommends to use special cable channel systems on top of the cabinets, where you dont have any raised oor or cable tray sys-
tems in your datacenters. This system is especially a very cost effective solution for datacenters with cold aisle containment systems
and inrow front coolers, where you dont need a raised oora. These channel system helps to guide , route and manage any copper or
ber cable directly through the top cover inside the rack.
67
inorax Outdoor Enclosures
inorax Outdoor Eclosures
Protected like a bunker for all harsh environments
68
inorax Outdoor Enclosures
IP 55 protection
Solid extruded aluminum prole construction- Completely Weld
free structure
Double-skin aluminum doors and panels with natural ventilation
system and integrated isolation material
Double-skin construction (sandwich technology) allows maxi-
mum heat dissipation by low inuence of sun irradiation and
offers maximum sealing effect
Special sun reecting and anti-grafti outdoor paint ensures up
to 6 C temperature isolation
Indoor paint ensures humidity absorbance by collecting humid-
ity created by active devices on the surface of the inner roof
Ventilated roof top ensures maximum ventilation through creat-
ing a chimney effect
Special bumps on all doors and panels disables advertisement
material posting on surfaces adversely effecting the appropri-
ate ventilation required for heat exchangers and AC units
Anti-vandal design
External access totally impossible provided by hidden hinges
Robust stainless steel locking system
Maximum protection against environmental impacts, vandal-
ism, EMC and extreme thermal effects
19 mounting rails for active equipment
Separate battery, MDF or custom sections according to cus-
tomized requirements
Laptop shelves on doors
Customer-specic solutions for installation and future expan-
sions
Fully integrated heat exchangers, air-conditioning and internal
heating are available upon request
IP 55 protected
Galvanized steel construction against corrosion and harsh
conditions
Double skin galvanized steel doors with isolation material inside
Seperate battery, 19 and MDF sections
Anti-vandalism design
Robust stainless steel locking system
Maximum protection against environmental impacts, vandal-
ism, EMC and extreme thermal effects
19 mounting rails for active equipment
Customer-specic solutions for installation and future expan-
sions
Fully integrated heat exchangers, air-conditioning and internal
heating are available upon request
Highlights Highlights
Outdoor enclosures and climate control components do withstand even
the toughest wind and weather conditions. From basic requirements such
as humidity, temperature uctuations and sunlight, to extreme conditions
such as seawater resistance or vibration-earthquake resistance, through
to protection against vandalism, Canovate has the answer. In this way,
we ensure that there are no limits to our customers applications including
DSLAM, MSAN, VDSL, 3G and 4G GSM networks, railway, energy and
trafc monitoring and transmission applications. Both of aluminum based or
galvanized steel based outdoor cabinets offer maximum protection against
environmental impacts, vandalism, EMC and extreme thermal conditions.
Outdoor Climate Control solutions provide everything you need to protect
your electronic equipment investment. All weather-tested enclosure air
conditioners, heat exchangers, fans, and heaters are especially designed
for extreme outdoor conditions to ensure constant interior temperature per-
formance.
Double Skin Aluminum Double Skin Galvanized
69
inorax Outdoor Enclosures
inorax-09 Outdoor Cabinet
Technical Features
Material
Protection Level
Finish
Technical Specications
Tests
Extruded aluminum chassis, double skin aluminum on door and
panels (outer panel 3 mm aluminum, inner panel 1.5 mm aluminum)
IP55
Chromated to DIN 50939 and antigraty&sun reecting epoxy
polyster outdoor paint
3 sections: 1x 19 Systems + 1MDF+1
Power, 3 doors Top Mounted Heat Exchanger
ETS 300019 and IEC 68-2-57 (Earthquake, shock, vibration, trans-
portation tests), EN 60529 and IEC5291 (IP 55 dust and waterproof tests),
EN 60950 (Electrical and mechanical safety tests)
1698 1155 405 OAD-7-1001
Height mm Width mm Depth mm Part No
Order Information
Double Skin Door
MDF Section
Power Box Section
Top Mountable Heat exchanger
19 Active Equipment Section
Related Accessories Rack Monitoring System
Power Distribution Units
Thermal Test
Temperature Distributions
Boundary Condations
Thermal study for extreme climatic conditions are done in approved laboratories
Streamlines, coloured with
ow velocity
Minimum Order Quantity:50 Pcs.
70
inorax Outdoor Enclosures
1500 1900 900 OAD-7-1002
Height mm Width mm Depth mm Part No
Order Information
inorax-10 Outdoor Cabinet
Technical Features
Material
Protection Level
Finish
Technical Specications
Tests
Extruded aluminum chassis, double skin aluminum on door and
panels (outer panel 3 mm aluminum, inner panel 1.5 mm aluminum)
IP55
Chromated to DIN 50939 and antigraty&sun reecting epoxy
polyster outdoor paint
4 sections: 2x 19 Systems + 1MDF+1 Bat-
tery, 7 doors Heat exchangers & AC units can be mounted on the doors
ETS 300019 and IEC 68-2-57 (Earthquake, shock, vibration, trans-
portation tests), EN 60529 and IEC5291 (IP 55 dust and waterproof tests),
EN 60950 (Electrical and mechanical safety tests)
1500 1600 900 OAD-7-1003
Height mm Width mm Depth mm Part No
Order Information
Material
Protection Level
Finish
Technical Specications
Tests
Extruded aluminum chassis, double skin aluminum on door and
panels (outer panel 3 mm aluminum, inner panel 1.5 mm aluminum)
IP55
Chromated to DIN 50939 and antigraty&sun reecting epoxy
polyster outdoor paint
3 sections: 1x 19 Systems + 1MDF+1 Bat-
tery, 4 doors Heat exchangers & AC units can be mounted on the doors
ETS 300019 and IEC 68-2-57 (Earthquake, shock, vibration, trans-
portation tests), EN 60529 and IEC5291 (IP 55 dust and waterproof tests),
EN 60950 (Electrical and mechanical safety tests)
inorax-11 Outdoor Cabinet
Technical Features
Related Accessories Rack Monitoring System
Power Distribution Units
inorax-12 Outdoor Cabinet
1390 1250 805 OAD-7-1004
Height mm Width mm Depth mm Part No
Order Information
Material
Protection Level
Finish
Technical Specications
Extruded aluminum chassis, double skin aluminum on door and
panels (outer panel 3 mm aluminum, inner panel 1.5 mm aluminum)
IP55
Chromated to DIN 50939 and antigraty&sun reecting epoxy
polyster outdoor paint
3 sections: 1x 19 Systems + 1MDF+1 Bat-
tery, 4 doors Heat exchangers & AC units can be mounted on the doors
Technical Features
Related Accessories Rack Monitoring System
Power Distribution Units
Minimum Order Quantity:50 Pcs.
Minimum Order Quantity:50 Pcs.
Minimum Order Quantity:50 Pcs.
71
inorax Outdoor Enclosures
Related Accessories Rack Monitoring System
Power Distribution Units
inorax-14 Outdoor Cabinet
1650 1190 690 OGD-7-1002
Height mm Width mm Depth mm Part No
Order Information
Technical Features
Material
Protection Level Finish
Technical Specications
Tests
Galvanized steel, double skin galvanized steel on door and
panels (outer panel 2mm aluzinc, inner panel 1.5 mm galvanized steel)
IP55 Epoxy polyster outdoor paint
4 sections: 2x 19 Systems + 1MDF+1 Bat-
tery, 5 doors Heat exchangers & AC units can be mounted on the doors
ETS 300019 and IEC 68-2-57 (Earthquake, shock, vibration, trans-
portation tests), EN 60529 and IEC5291 (IP 55 dust and waterproof tests),
EN 60950 (Electrical and mechanical safety tests)
Protection Level
Finish
Highlights
IP55
Epoxy polyster outdoor paint
Single skin galvanized steel construction
Special anti-vandal key system with special 3 points locking mechanism
Special cable entry system on the bottom with cable glands
inorax-15 Outdoor Cabinet
Compact single skin copper cross connect cabinet for small scale copper
distribution applications
Related Accessories Rack Monitoring System
Power Distribution Units
1240 750 290 OGS-7-1005
Height mm Width mm Depth mm Part No
Order Information
Technical Features
Material
Tests
Single skin galvanized steel - 2 mm
ETS 300019 and IEC 68-2-57 (Earthquake, shock, vibration, trans-
portation tests), EN 60529 and IEC5291 (IP 55 dust and waterproof tests),
EN 60950 (Electrical and mechanical safety tests)
Related Accessories Rack Monitoring System
Power Distribution Units
inorax-13 Outdoor Cabinet
1650 1774 790 OGD-7-1001
Height mm Width mm Depth mm Part No
Order Information
Minimum Order Quantity:50 Pcs.
Minimum Order Quantity:50 Pcs.
Minimum Order Quantity:50 Pcs.
Technical Features
Material
Protection Level Finish
Technical Specications
Tests
Galvanized steel, double skin galvanized steel on door and
panels (outer panel 2mm aluzinc, inner panel 1.5 mm galvanized steel)
IP55 Epoxy polyster outdoor paint
4 sections: 2x 19 Systems + 1MDF+1 Bat-
tery, 5 doors Heat exchangers & AC units can be mounted on the doors
ETS 300019 and IEC 68-2-57 (Earthquake, shock, vibration, trans-
portation tests), EN 60529 and IEC5291 (IP 55 dust and waterproof tests),
EN 60950 (Electrical and mechanical safety tests)
72
inorax Outdoor Enclosures
inorax-17 Outdoor Cabinet
An ultimate solution for outdoor copper cable connection and distribution
applications. Special glass ber reinforced polycarbonate structure makes
this cabinet an ideal solution for cross-connect applications of Telecom
and Cable TV companies. The structure is a blend of low weight and high
mechanical strength and its functional design gives extra advantages both
for installation and cable management.
Material Protection Level
Highlights
Glass ber reinforced polycarbonate IP55
Weather-proof outdoor cabinet for cross connect applications
Double door access with 2400 pairs capacity (Krone Type)
Front and rear door
Locking systems: 3 points , 2 vertical bars, 1 lock
Easy to install on a pedestal with bottom cable entries
Impact resistant
4 Vertical mounting rails
RAL7038
Technical Features
998 757 310 50 OPD-7-1001
Height mm Width mm Depth mm Weigth kg Part No
Order Information
Related Accessories Rack Monitoring System
Power Distribution Units
Related Accessories Rack Monitoring System
Power Distribution Units
Order Information
inorax-16 Outdoor Cabinet
This outdoor cabinet is an ideal small size solution for any 19 active equip-
ment installation and a perfect ber cross connect cabinet for FTTX ap-
plications.
Highlights
Plinth
Weather-proof outdoor cabinet for installation of 19 active equipment
and optical distribution modules
Assembly of modular optical building blocks like splice, patch and
splitter modules
Provides a secure anchor for incoming loose tube cables within the
cabinet
Easy installation and removal
Doors are protected from external access through hidden hinges
High resistivity against corrosion
1 pair of 19 inch mounting rails (Optional 2 pairs)
Single front door
CNC controlled polyurethane (PUR) gasketing is available for all of the
complete openable surfaces of the outdoor to provide IP65 protection
degree ,which is complying with the EN6O529 standard
1,5 mm mounting plate for cable management on the back side
C-rail for xing cables on the back side
Optional: Mounting brackets for wall applications
250 mm (H) plinth is included in standard conguration
Height U Height mm Width mm Depth mm Weight kg Part No
OGS-7-1002
OGS-7-1003
OGS-7-1004
12U
16U
24U
912
1090
1200
620
620
620
450
450
450
53.00
64.00
82.00
Technical Features
Material Protection Level
Finish
Single skin galvanized steel - 2 mm IP65
Epoxy polyster outdoor paint, RAL 7035
Minimum Order Quantity:50 Pcs.
Minimum Order Quantity:50 Pcs.
73
inorax Outdoor Enclosures
Fans
Cabinet
Filter MEF
Impure air
Door
F
i
l
t
e
r
e
d

a
i
r
Direct Air Cooling-Membrane Filter & Fan system
Highlights
Nominal dimension: 500 x 500 x 40mm
Humidity resistance
Classication EN779-F9
Initial charge loss 15MMca
Cool air
Hot air
Cabinet
Cool air
Hot air
Compressor
Fan
Capacitor
Fan
Evaporator
Thermal Management
Air conditioner
Ensures that the proper interior temperature is maintained inside your
enclosure. Conveniently mounted on the front or rear door with adjust-
able internal, mid, or external mounting cabability. These reliable products
give you the exibility you need to meet the strigent requirements for your
unique outdoor application
Unlike bulky heat exchangers and air-conditioning systems, Direct
Air Cooling (DAC) systems with Membrane Cooling Filters have
fewer mechanical parts. They are also easier to incorporate into
cabinet designs, and require less maintenance. These cooling filters
reduce ongoing operating costs, because they use less energy than
mechanical systems; and reduce overall cabinet size to save space.
Reliable protection of system electronics requires highly efficient
filtering of ambient air to remove submicron particles and aerosols
while also preventing water ingress into the cabinet. This is best
achieved by using membrane filter, which provides 99% particle fil-
tration efficiency at the 0.3um level yet still allows high airflows. Not
only do membrane filters eliminate costly failures caused by corro-
sion and other pollutants, but they are also maintenance free and
have longer lifetimes than non-membrane alternatives. Membrane
filters have been specifically developed for outdoor cooling and pro-
tection under extreme environmental and climatic conditions.
Refrigeration capacity: 300W - 3500W
Noise level: 65 dB, according to ETS300753 Class 4.1
IP54 protection
Feeding: AC
Designed to ease regular maintenance
Quick-removable front casing
Components designed for quick cleaning and maintenance
Easy lter replacement
Lower maintenance costs
CE approved
Air to Air heat exchangers
Outdoor Air to Air heat exchangers ensure that the proper interior tem-
perature is maintained inside your enclosure. Conveniently mounted
on the front or rear door with adjustable internal, mid, or external
mounting cabability. These reliable products give you the flexibility you
need to meet the stringent requirements for your unique outdoor ap-
plication. Closed-loop cooling maintains a clean, sealed internal en-
vironment to insure optimum performance and maximum life of the
enclosed electronics, while protecting against the intrusion of airborne
contaminants and humidity.
I
n
t
e
r
n
a
l

c
i
r
c
u
l
a
t
i
o
n
C
a
b
i
n
e
t
Fan
Hot air
Cool air
Thermal
exchange
area
E
x
t
e
r
n
a
l

c
i
r
c
u
l
a
t
i
o
n
Technical specications
Technical specications
Capacity: 30W/K to 120W/K
IP54 protection
Noise level: 75 dB according ETS300753 Class 4.1 E
Feeding: 48V DC ,
Closed Loop Cooling for Controlled Environments
Efciently Coated Aluminum Heat-Transfer Core- Cross Flow Type
Speed controlled fans
CE approved
74
PDU Solutions
PDU Solutions
Canovate offers a full range of PDUs from basic and metered ones to IP PDUs with per socket switching
capability and wireless sensor connectivity. Our PDUs can be used in the most complex ISP and
Colocation datacenter applications and provide you the opportunity to control, monitor your energy
comsumption and help you to make the correct billing to your customers.
75
PDU Solutions
Density Single-power inlet; 7-12 outlets (Schuko-C13) per rack-mount
1.5U enclosure Max 36 outlet for vertical 0U models
Power 250VAC, 50/60 Hz, 16 or 32-Amp power inlet options. Single or
3 phase option
SCHUKO TYPE
UK TYPE
IEC C13 TYPE
FRENCH TYPE
UNIVERSAL TYPE
BASC PDU
Product Code
Product Code
Product Code
Product Code
Product Code
Product Description
Product Description
Product Description
Product Description
Product Description
PB-S04-100-116
PB-S04-020-116
PB-S06-100-116
PB-S06-020-116
PB-S08-100-116
PB-S08-020-116
PB-S12-100-116
PB-S12-020-116
PB-S16-100-132
PB-S16-020-132
PB-S18-100-132
PB-S18-020-132
PB-U05-100-116
PB-U05-020-116
PB-U07-100-116
PB-U08-100-116
PB-U08-020-116
PB-U12-100-116
PB-U12-020-116
PB-U16-100-132
PB-U16-020-132
PB-U18-100-132
PB-U18-020-132
PB-C06-100-116
PB-C06-020-116
PB-C08-100-116
PB-C08-020-116
PB-C12-100-116
PB-C12-020-116
PB-C15-100-132
PB-C16-100-132
PB-C16-020-132
PB-C18-100-132
PB-C18-020-132
PB-F06-100-116
PB-F06-020-116
PB-F08-100-116
PB-F08-020-116
PB-F12-100-116
PB-F12-020-116
PB-F16-100-132
PB-F16-020-132
PB-E06-100-116
PB-E06-020-116
PB-E08-100-116
PB-E08-020-116
1U 19 Aluminum 4 way with on/off switch
1U 19 Aluminum 4 way with circuit breaker
1U 19 Aluminum 6 way with on/off switch
1U 19 Aluminum 6 way with circuit breaker
1U 19 Aluminum 8 way with on/off switch
1,5U 19 Aluminum 8 way with circuit breaker
1,5U Vertical Aluminum 12 way with on/off switch
1,5U Vertical Aluminum 12 way with circuit breaker
1,5U Vertical Aluminum 16 way with on/off switch
1,5U Vertical Aluminum 16 way with circuit breaker
1,5U Vertical Aluminum 18 way with on/off switch
1,5U Vertical Aluminum 18 way with circuit breaker
1U 19 Aluminum 5 way with on/off switch
1U 19 Aluminum 5 way with circuit breaker
1,5U 19 Aluminum 7 way with on/off switch
1,5U 19 Aluminum 8 way with on/off switch
1,5U 19 Aluminum 8 way with circuit breaker
1,5U Vertical Aluminum 12 way with on/off switch
1,5U Vertical Aluminum 12 way with circuit breaker
1,5U Vertical Aluminum 16 way with on/off switch
1,5U Vertical Aluminum 16 way with circuit breaker
1,5U Vertical Aluminum 18 way with on/off switch
1,5U Vertical Aluminum 18 way with circuit breaker
1U 19 Aluminum 6 way with circuit breaker
1U 19 Aluminum 6 way with on/off switch
1U 19 Aluminum 8 way with circuit breaker
1U 19 Aluminum 8 way with on/off switch
1U Vertical Aluminum 12 way with on/off switch
1U Vertical Aluminum 12 way with circuit breaker
1U Vertical Aluminum 15 way with on/off switch
1,5U Vertical Aluminum 16 way with on/off switch
1,5U Vertical Aluminum 16 way with circuit breaker
1,5U Vertical Aluminum 18 way with on/off switch
1,5U Vertical Aluminum 18 way with circuit breaker
1U 19 Aluminum 6 way with on/off switch
1U 19 Aluminum 6 way with circuit breaker
1U 19 Aluminum 8 way with on/off switch
1,5U 19 Aluminum 8 way with circuit breaker
1,5U Vertical Aluminum 12 way with on/off switch
1,5U Vertical Aluminum 12 way with circuit breaker
1,5U Vertical Aluminum 16 way with on/off switch
1,5U Vertical Aluminum 16 way with circuit breaker
1U 19 Aluminum 6 way with on/off switch
1U 19 Aluminum 6 way with circuit breaker
1U 19 Aluminum 8 way with circuit breaker
1U 19 Aluminum 8 way with on/off switch
76
PDU Solutions
Numeric Led display with ampermeter mod-
ule Measures current between 0 and 30 A
Voltmeter module with Numeric Led display.
Measures voltage between 0 and 500 VAC
Metered PDU
PROTECTED PDU
PA-S06-000-116
PV-S06-000-116
PA-S08-000-116
PV-S08-000-116
PA-S12-000-116
PV-S12-000-116
PA-S16-000-132
PV-S16-000-132
PA-S18-000-132
PV-S18-000-132
PA-S05-001-116
PA-S05-010-116
PA-S04-011-116
PV-S05-001-116
PV-S05-010-116
PV-S04-011-116
PA-S07-001-116
PA-S07-010-116
PA-S06-011-116
PV-S07-001-116
PV-S07-010-116
PV-S06-011-116
PA-S11-001-116
PA-S11-010-116
PA-S10-011-116
PV-S11-001-116
PV-S11-010-116
PV-S10-011-116
PA-S15-001-132
PA-S15-010-132
PA-S14-011-132
PV-S15-001-132
PV-S15-010-132
PV-S14-011-132
PA-S17-001-132
PA-S17-010-132
PA-S16-011-132
PV-S17-001-132
PV-S17-010-132
PV-S16-011-132
PA-U06-000-116
PV-U06-000-116
PA-U08-000-116
PV-U08-000-116
PA-U12-000-116
PV-U12-000-116
PA-U16-000-132
PV-U16-000-132
PA-U18-000-132
PV-U18-000-132
PA-U05-001-116
PA-U05-010-116
PA-U04-011-116
PV-U05-001-116
PV-U05-010-116
PV-U04-011-116
PA-U07-001-116
PA-U07-010-116
PA-U06-011-116
PV-U07-001-116
PV-U07-010-116
PV-U06-011-116
PA-U11-001-116
PA-U11-010-116
PA-U10-011-116
PV-U11-001-116
PV-U11-010-116
PV-U10-011-116
PA-U15-001-132
PA-U15-010-132
PA-U14-011-132
PV-U15-001-132
PV-U15-010-132
PV-U14-011-132
PA-U17-001-132
PA-U17-010-132
PA-U16-011-132
PV-U17-001-132
PV-U17-010-132
PV-U16-011-132
PA-C06-000-116
PV-C06-000-116
PA-C08-000-116
PV-C08-000-116
PA-C12-000-116
PV-C12-000-116
PA-C16-000-132
PV-C16-000-132
PA-C18-000-132
PV-C18-000-132
PA-C05-001-116
PA-C05-010-116
PA-C04-011-116
PV-C05-001-116
PV-C05-010-116
PV-C04-011-116
PA-C07-001-116
PA-C07-010-116
PA-C06-011-116
PV-C07-001-116
PV-C07-010-116
PV-C06-011-116
PA-C11-001-116
PA-C11-010-116
PA-C10-011-116
PV-C11-001-116
PV-C11-010-116
PV-C10-011-116
PA-C15-001-132
PA-C15-010-132
PA-C14-011-132
PV-C15-001-132
PV-C15-010-132
PV-C14-011-132
PA-C17-001-132
PA-C17-010-132
PA-C16-011-132
PV-C17-001-132
PV-C17-010-132
PV-C16-011-132
1U 19 Aluminum 6 way with Ampermeter
1U 19 Aluminum 6 way with Voltmeter
1,5U 19 Aluminum 8 way with Ampermeter
1,5U 19 Aluminum 8 way with Voltmeter
1,5U Vertical Aluminum 12 way with Ampermeter
1,5U Vertical Aluminum 12 way with Voltmeter
1,5U Vertical Aluminum 16 way with Ampermeter
1,5U Vertical Aluminum 16 way with Voltmeter
1,5U Vertical Aluminum 18 way with Ampermeter
1,5U Vertical Aluminum 18 way with Voltmeter
1U 19 Aluminum 5 way with Ampermeter, SP
1U 19 Aluminum 5 way with Ampermeter, CB
1U 19 Aluminum 4 way with Ampermeter, CB+SP
1U 19 Aluminum 5 way with Voltmeter, SP
1U 19 Aluminum 5 way with Voltmeter, CB
1U 19 Aluminum 4 way with Voltmeter, CB+SP
1,5U 19 Aluminum 7 way with Ampermeter, SP
1,5U 19 Aluminum 7 way with Ampermeter, CB
1,5U 19 Aluminum 6 way with Ampermeter, CB+SP
1,5U 19 Aluminum 7 way with Voltmeter, SP
1,5U 19 Aluminum 7 way with Voltmeter, CB
1,5U 19 Aluminum 6 way with Voltmeter, CB+SP
1,5U Vertical Aluminum 11 way with Ampermeter, SP
1,5U Vertical Aluminum 11 way with Ampermeter, CB
1,5U Vertical Aluminum 10 way with Ampermeter, CB+SP
1,5U Vertical Aluminum 11 way with Voltmeter, SP
1,5U Vertical Aluminum 11 way with Voltmeter, CB
1,5U Vertical Aluminum 10 way with Voltmeter, CB+SP
1,5U Vertical Aluminum 15 way with Ampermeter, SP
1,5U Vertical Aluminum 15 way with Ampermeter, CB
1,5U Vertical Aluminum 14 way with Ampermeter CB+SP
1,5U Vertical Aluminum 15 way with Voltmeter, SP
1,5U Vertical Aluminum 15 way with Voltmeter, CB
1,5U Vertical Aluminum 14 way with Voltmeter CB+SP
1,5U Vertical Aluminum 17 way with Ampermeter, SP
1,5U Vertical Aluminum 17 way with Ampermeter, CB
1,5U Vertical Aluminum 16 way with Ampermeter CB+SP
1,5U Vertical Aluminum 17 way with Voltmeter, SP
1,5U Vertical Aluminum 17 way with Voltmeter, CB
1,5U Vertical Aluminum 16 way with Voltmeter CB+SP
SP : Surge Protector CB : Circuit Breaker
Schuko Type
Schuko Type
UK Type
UK Type
IEC C13 Type
IEC C13 Type
Product Description
Product Description
Density Single-power inlet; 6-11 (Schuko-C13) outlets per rack-mount
1.5U enclosureMax 32 outlet for vertical 0U models
Power 250VAC, 50/60 Hz, 16 or 32-Amp power inlet options.
Input Current Monitor Precisely measure the aggregate current (in amps)
of power inlet. On-site verifcation of the input current with the LED digital
display. (Optional voltage monitor)
Density Single-power inlet; 5-10 (Schuko-C13) outlets per rack-mount
1.5U enclosure, Max 32 outlet for vertical 0U models
Power 250VAC, 50/60 Hz, 16 or 32-Amp power inlet options.
Protection Surge & spike protection, Circuit breaker, optional ON/OFF
switch
77
PDU Solutions
Extendable PDU
Density IEC 309 power inlet; 4xC19 cable outlets
Power 250VAC, 50/60 Hz, 32-Amp power inlet options.
Protection 2 poles Circuit braker for each expansion unit
Hot swappable expansion units with LED indicator
Density 1xC20 inlet for main unit connection, 7xC13 outlets
Power 250VAC, 50/60 Hz, 16A
Extendable PDU is the most suitable solution to the users who want to
control and maximize the space efciency in the rack. The special design
that is composed of two parts; the control unit and extension units, offers
maximum modularity. PDU provides 28 outputs by connecting 4 extension
units to one control unit. The control unit is zero-U rack mountable.You can
install to the side or back of the rack without sacricing any U space in
the rack. Also the extension bars can be install to the frame of the rack.
Main unit
Expansion unit
Control Unit
Extension Unit
Product Code Product Description
PE-040-020-132
PF-C07-000-116
Control Unit with 4 Branch
Extension Unit with 7 C13 Sockets
Modular PDU
Canovate Modular PDU offers exibility to design you own PDU that exact-
ly meet your needs. The special light weighted housing design is the key
to modularity. Also the wide range of modules, which enable users to mix
and match socket styles, let you arrange the socket density in you applica-
tions. In adition to product choice and conguration exibility the modules
are also hot swappable. That means you can disconnect, change or swap
any of the modules that is installed without stopping the whole PDU. Just
detach devices that is connected to the module, remove the original and
snap-in the replacement.
4 way Schuco module
Single Input
Master Circuit Breaker Module
5 way IEC module
3 way UK module
Product Code
Product Code
Product Description
Product Description
PM-002
PM-004
PM-006
PQ-B02-010-116
PQ-U03-000-116
PQ-S04-000-116
PQ-C05-000-116
Aluminum Housing with 2 Module Capacity
Aluminum Housing with 4 Module Capacity
Aluminum Housing with 6 Module Capacity
Master Circuit Breaker Module
3 way UK module
4 way Schuco module
5 way IEC module
Main Unit
Density Single power inlet; 6xSlots for hot swappable modules.
Power 250VAC, 50/60 Hz, 32-Amp power inlet options.
Protection Circuit braker on master module (5 slots stay to be congura-
ble, if used)
Modules Hot swappable modules
Density Congurable with 3 way UK, 4 way Schuko, 5 way C13 outlets
Power 250VAC, 50/60 Hz, 16A
78
PDU Solutions
Product Code
Product Code
Product Code
Product Description
Product Description
Product Description
PDC-K10-010-132
PH-C12-022-116-001
PH-C08-080-116-L
-48 VDC, 32 A, 10 ports output PDU
16 A , 12 C13 outputs
16 A , 8C13 outputs fuse protection on each outlets
DC PDU
Density Double DC power inputs, 16 electrical connector type output, 2U
enclosure
Power 32 to 76VDC input, 16- 32- 64 Ampere power output options.
Max. 120 A.
Material 2U steel enclosure, plexiglass cover and internal seperators.
Viewable gap on the protection cover of brakers, Main bus bar for distri-
bution to electrical connector contacts, Colored line outs and sequence
numbers
Applications Telco applications, base stations
Canovate offers a power distributioon unit for both power protection and
distribution for rack-mounted servers.
High Protection PDU provides twelve IEC C13 output receptacles that
dispribute power.
High Protection PDU also consumes rack U-space with 1U or ZeroU
mounting options. The product has height of 4.4 cm which is suitable for
both zero-U and 1U rack mount option.
Highlights
Designed to t into rack cabinets
Circuit breaker protected
12 IEC 320 outputs
Surge and spike protection on modular based
Specication
Single input - 12 C13 outputs
16 A current capacity
230 V output sockets
Dual Circuit breaker, each controls six outputs
Input frequency 50/60 Hz
Surge suppression camping level 275 to 320V RMS
Surge current 10,000 A
Spike Protection 500 joules, 10x1000 usec
Canovate offers a power distributioon unit with power protection and pow-
er metering capability for rack-mounted server's power distributions.
High Protection PDU provides eight IEC C13 output receptacles that dis-
tribute power.
High Protection PDU consumes 1U from Rack's U-space. The product
has height of 4.45 cm which is suitable for both zero-U and 1U rack mount
option.
Highlights
Designed to t into 19" rack cabinets
Fuses protection for each outlets (2A)
8 IEC 320 C13 outputs with led indicators
Specication
Single input - 8C13 outputs
16 A Total input current capacity
230 V output sockets
Fuses for each outlets
Input frequency 50/60 Hz
Ampermeter
Outlets Power Inlet
Fuses per outlets
Lets
Ampermeter
High Protection PDU
Metered High Protection PDU
79
PDU Solutions
Product Code Product Description
PS-S10-000-116 IP-PDU 10 way Schuko Sockets
IP PDU
Metered IP PDU
Switched and Outlet Level Monitored IP PDUs
IP PDU is a simple solution where reliable power distribution for home and
ofce appications is needed, in addition to the branch circuit protection. IP
PDU also provides power control and environmental monitoring using inter-
net connection. There wont be any problem like disconnection of server,
switch-lock or router-lock especially in IT center. Reset your routers with re-
mote control. You can control your home appliances by your mobile phone
or any internet connection.You can also reset ATM units remotely
Smart Switched PDUs become integral parts of modern datacenter envi-
ronment to control your energy consumption, to control&monitor your ac-
tive devices remotely and to monitor all environmantal factors, which will
affect the performance of your datacenter.
Switch POPS (Per Outlet Power Sensing) units monitor,control and man-
age servers (Blade servers) and IT equipment and the equipment cabinet
infrastructure that houses them POPS Power information per individual
outlet includes: current load (A), voltage (V), power (kW), apparent power
(VA), crest factor, and power factor. Using grouping technology, power in-
formation is available per device, groups of devices (application), individual
Cabinet PDU or cabinet. kW and kW-hour power information that can be
utilized for billing your customers in Colocation datacenters and to take
power reports for controlling your energy consumption
Density 8-12 (C13) outlets per rack mount 19 1U horizantal, 24 outlets
(3x16 C13 and 3x2 C19) per 0U vertical models
Power 230VAC, 50/60 Hz, 16 or 32-Amp power inlet options.
Protection 2 poles circuit braker
Metering Volt and Amperemeter display, temperature and humidity sensor
connectivity. RMS current and active power measurement for inlet
Monitoring Optional rack and room environment monitoring system con-
nectivity support to enhance monitoring capabilities such as room tem-
perature, room humidity,
Smoke, noisy, PIR, LPG, NLG gas, water leakage, air ow, door and frame
camera.
Management IP based WEB Access, http, SMTP, SNMP, SNTP protocol
Support, e-mail sending feature
Options Environmental monitoring integration
LED indicator per Outlet
Density 8-12 (C13) outlets per rack mount 19 1U horizantal, 24 outlets
(3x16 C13 and 3x2 C19) per Zero U vertical models
Power 230VAC, 50/60 Hz, 16 or 32-Amp power inlet options.
Protection 2 poles circuit braker
Metering Volt and Amperemeter display, temperature and humidity sensor
connectivity. RMS current and active power measurement for inlet
RMS current, active power measurement per outlet including preset con-
dition control
Monitoring Optional rack and room environment monitoring system con-
nectivity support to enhance monitoring capabilities such as room temper-
ature, room humidity, Smoke, noisy, PIR, LPG, NLG gas, water leakage, air
ow, door and frame camera
Management IP based WEB Access and outlet level control, http, SMTP,
SNMP, SNTP protocol Support, e-mail sending feature, Outlet grouping
Options Environmental monitoring integration with wireless sensors
LED indicator per Outlet
Ethernet
Connection
Camera Connection USB Port Sensor Connections
Product Code Product Description
PP-C08-020-116
PP-C12-020-116
PP-C24-020-116
IP-PDU 8 way IEC C13 Sockets
IP-PDU 12 way IEC C13 Sockets
IP-PDU 24 way IEC C13&C19 Sockets
80
Quality Certi cates
81
Quality Certi cates