Sie sind auf Seite 1von 26

5

Chocolate characterisation by using Laser Diffraction Particle Size Analyzer


Chocolate is produced by processing cocoa powder along with milk and fats. The most
important factor which interest costumer to consume chocolates is the flavor strength that
chocolate created which is indicated by the taste of chocolate. Chocolate can be either bitter
or sweet depending on the amount of cocoa used in the production. The art of consuming
chocolates also relies on the chocolates texture, whether the chocolate is rough or smooth on
the surface and the hardness of chocolate. The hardness of chocolate is governed by
combination of the crystallized lipid phase and the solid dispersed phase. Not only affected
by ratio of lipid and solid phase, the hardness of chocolate can vary depends on the packaging
along with its storing condition (Windhab,2006). The other factors influenced chocolate
consumption is chocolates physical appearance and how the environment affects it such as
how the chocolate melts in the tongue due to the heat caused by human body. When aimed
for smoother chocolate, milk fat is added into the mixture to soften cocoa butter to produce
lighter soft chocolate (Rowat, 2011). According to Powis, 2012, interactions between raw
materials combine with the correct manufacturing process would effect on the properties and
structure of chocolate produced.
Focusing on the physical properties of chocolate by relating back to its processing operations,
the most important parameter that needs to be considered in order to produce chocolates as
desired is the particle size distribution of chocolate. Particle size distribution becomes a
crucial factor because it is closely related to how the produced chocolate will turn out to be
especially regarding to its rheological behaviour and mechanical properties (Afoakwa, 2008).
Throughout the process of manufacturing chocolate products, particle size distribution must
be carefully controlled and maintain constantly since a little difference would lead to
significant change to the chocolate produced and would effect on the oral behaviour when the
chocolate is being consumed. Furthermore, particle size distribution in chocolate is also used
to identify chocolates final structure and its final taste, whether the chocolate will be smooth,
creamy or rigid and also the level of bitter and sweetness of chocolate product itself (Do,
2007). Do, 2007 also stated that if the chocolate particles are large meaning that small
particle size distribution occurs and would result on a less creamy structure when compared
to particles with larger particle size distribution. Chocolate would taste bitter due to small
particle size distribution and would result on a more dense structured chocolate (Afoakwa,
2008).
6


Fig 1. Factors influenced oral processing for chocolate (Gaikwad, 2012)
There are many ways to determine the particle size distribution and particle size of
chocolates, for example through the process of screening. Screening is commonly used to
determine particle size distribution on particles which has size larger than approximately
about 40-60 m. Unfortunately, this process become inaccurate when the particle is smaller
than the required range (Gaikwad, 2012). For small particle, common methods used to
characterize particle size distribution is done by gravimetric registration of settling,
observation of the change of transparency of suspension, microscopic particle counters with
digital marking, electrical resistance changes and light scattering in laser beam (Mohos,
2010). Some of the methods relating to calculation of particle size which is used in the
industry will be explain in this report.
Chocolate has small particle size, sizing in approximately 18-35 m (Afoakwa, 2008),
therefore determining particle size distribution of chocolate cannot be done by screening
method. The most common equipment used in the chocolate manufacturing industry to
determine particle size distribution of chocolate is laser diffraction (Malvern Instruments,
2010). Due to its simplicity and reasonable pricing, laser diffraction is a favourable
measurement tool to study and examine particle size distribution (Mohos, 2010). Nowadays,
modern laser diffraction tools are automated and standardized to allow a more accurate
calculation to be resulted. The use of laser diffraction as a measurement tool also offers a less
time consuming analytical process when compared to other particle size distribution
analytical methods (Afoakwa, 2008).
How does Laser Diffraction works?
Laser diffraction which is invented based on the theory of light scattering, is now widely used
in industry and believed to be the most effective measurement technique in calculation of
particle size (Kippax, 2005). Light patterns used to characterise the particle size are then
processed into mathematical analysis which is then further processed to produce an accurate
picture of particle size distribution of the object. To achieve that goal, laser diffraction is
particle phase
-. composition: cocoa particles, milk
solid, crystalline sugar
-. physical attributes:
particle size, shape, material
properties
Major physical properties of
importance to oral processing
-. particle size distribution
-. hardness
-. melting behaviour
-. mechanical and rheological
behaviour
Oral behaviour
7

commonly equipped with a computer and microscope to determine the type and shape of
observant particle.

Fig 2. How laser diffraction works
All the equipment required for laser diffraction and how the light scatter on the object and
results an image projected to the multi-element detector is shown in Fig2. Chocolate sample
is prepared under certain concentration dissolved in a suitable liquid. Fat-containing materials
are dissolved in the liquid while particles are suspended. Most commonly used solvent is
tricholoroethane, but due to the danger it causes to food products, the use of it has been
replaced with sunflower oil or isopropyl alcohol (Malvern Instrument,2010). Chocolate
sample is then placed in the middle of parallel beam in where a laser of monochromatic light
source is shot at. Once it hit the sample, monochromatic light produces different scattering
angles which are then followed through multi-element detector in where it is recorded for
analysis. Smaller particles diffract light at a wider angles and different intensities than larger
particles. From the detector, numerical values are produced and calculated using optical
model and mathematical equation to produce ratio of total volume over number of particles
resulting volumetric particle size distribution (Pain, 2005).
Fraunhofer diffraction theory and Mie scattering theory
The signal of measurement from multi element detector is translated into particles size
through mathematical calculation based on theory known as Fraunhofer and Mie theory. The
correct equation and formulae are needed be applied in order to lessen error calculation
especially for the small particles.
Mie theory is a more complex theory which is applied to determine particle size distribution
while Fraunhofer diffraction is a simpler form of Mie scattering theory. However, fraunhofer
diffraction can only be used to measure particles bigger than the incidence wave length (Pain,
2005).
8

According to Fraunhofer diffraction theory, when a spherical particle of diameter (d) is
within measurement area, its light intensity distribution of any angle is:

In the equation:
f the focal length of receiving lens
the wavelength of incidence light
J1 first order Bessel function =


X : u t sin d
scattering angle
min : 1.22 /D
Based on the calculation of light intensity from equation 1, it resulted a graphic drawn in fig
3. From the graphic, it would also represent the distribution of particle sizes of material being
observed since light intensity pattern has correspondence relationship with particle size
(Interference and Diffraction).

Fig 3. Fraunhofer diffraction patern for a circular aperture (Interference and Diffraction)
When smaller particles are required to be measure, Mie theory is used as its based of
calculation. However, the use of Mie theory requires knowledge of parameter such as
refractive index and absorption value. The refractive index can be calculated by using
refractometer measurement or it can also be calculated using empirical methods (Malvern,
2008).
( )
( )
( ) 1 2
16
2
1
2 2
4 2
0

(

=
X
X J
f
d
I I

t
u
9


Fig 4. Appearance of particles and the absorption value (Malvern, 2008)
While the absorption value can be evaluated by estimating particles physical appearance
under a microscope comparing it to fig 4. Based on calculation of calcium carbonate with
refractive index of 1.57 and the absorption of 1, 0.1, 0.01 , particle size distribution from
those values is plotted in fig 3 (Malvern, 2011).

Fig 5. Particle size distribution resulted from laser diffraction calculation (Malvern, 2011)
Advantages and Disadvantages of Laser Diffraction
Despite all its advantages stated above, the used of laser diffraction in the industry to analyze
particle size distribution addresses few disadvantages within the chocolate manufacturing
industry. A list of benefits and disadvantages is stated in table 1.





10

Table 1. Advantage and Disadvantage of Laser Diffraction Application (Kippax, 2005)
Advantage Disadvantage
Applied in a wide range of industrial
application.
Low resolving power. Narrow, the difference
in size between particles must be at least 15%
This technique is very flexible and able to
measure a wide range of particle size from
micron to milimeters.

The final result depends on accuracy of
refractive index and light absorption and also
information about particle shape.
A fast measuring time is needed It cannot be used to measure mix of particles
with different optical properties.
Because it requires less-time, measurement
can be done over several times providing
more data to be averaged therefore resulting a
more accurate measurement.
Often, problems are caused by particles
which strongly absorbs light because it may
not produce stable scattering signal.

Ease of verification. Laser diffraction
requires no calibration and can be verified
easily.


Other techniques that are used to characterise chocolate
There are other similar methods that can be used to analyse particle size distribution of
chocolate. One closely related to laser diffraction process is dynamic light scattering (DLS).
Similar to laser diffraction, DLS also uses light although the use of light in dynamic light
scattering is used to reflect the Brownian motion of particles. Brownian motion is measure in
the function of time. Dynamic light scattering is rarely used in characterising chocolate
because it produces low resolution (CPS Instrument Europe). Due to chocolate particles
which are similar in size, it would be harder to differ from one another.
Coulter counter is another method commonly found in industry and mostly prefered as a
method in analysing particle size distribution. Volume of particle is measured by allowing
number of suspended particles to pass through an orifice which is immersed by an electrode.
Electrical resistance measurement technique is used as based calculation of coulter counter
process. Although coulter counter produces high resolution result and can be applied to
calculate in a wide range of diameter ranging from 0.5-400 m, but this method is not
suitable in chocolate characterisation due to high density of chocolate paste. Also coulter
counter process needs calibration and produces error when used to measure low particle
concentration (Graham, 2003).
Not only particle size distribution, rheology of chocolate also plays an important role in
determining the quality in taste and physical behaviour of chocolate product. Rheology of
11

chocolate is usually based on yield stress and viscosity parameters. Conventionally, the
International Confectionery Association (ICA) recommended the use of rotational viscometer
with concentric cylinders for rheological measurement (Afoakwa et al, 2009). The use of
rotational rheometer allows controlling the applied shear stress and shearing strain in order to
create a flow curve. The viscosity of chocolate is determine by measuring the resistance of
rotating cylinder encounters in a chocolate at a specific temperature since viscosity and yield
value are temperature dependant. There are three types of rotational rheometer used in the
industry for measuring rheological of chocolate; coaxial cylinders, parallel plate and cone and
plate rheometers.
Nowadays, the method of calculating shear viscosity and yield stress of chocolate using
Magnetic Resonance Imaging visometric is widely used in chocolate manufacturer to
calculate rheological properties for quality assurance of chocolate product (Wichchukit et al,
2005). Magnetic Resonance Imaging viscometric (MRI) is believed to be a non-destructive
technique and a rapid process since shear rate and shear stress value can be calculated from a
single flow rate measurement. Other advantage of MRI viscometric is that it is an in-line
instruments allowing real time controlling of the process (Goloshevsky, A.G et al. 2005).
When compared to other conventional viscometer and rotational viscometer, MRI
viscometric is favourable because it provides a velocity profile image that can be used to
study slip phenomena (Wichchukit, 2004).
The effect of microstructure to the texture and physical appearance of chocolate
products
Particle microstructure has significant impact on the rheology of chocolate. The
determination of rheological properties of chocolate is important in manufacturing processes
for obtaining high quality products with well-defined texture. The texture properties of
chocolate are identified by the hardness it is in the mouth, meltabilitily, smoothness and
stickiness (El-Kalyoubi,2011). Factors such as fat content, moisture content, emulsifiers,
temperature and particle size distribution contributes to the rheological properties which
effect texture of chocolate product (Albrecht et al, 2011).
Viscosity is one of the rheological properties which is easily influenced by the external
factors but can easily calculate and controlled as well. Some studies have found that
chocolates of high viscosity have a pasty mount feel which last longer in the mouth than the
one with lower viscosity but too high of viscosity would result a very hard solid-like
12

chocolate (El-Kalyoubi, 2011). According to Windhab, to produce a smooth and creamy
chocolate, chocolate must be processed to have a viscosity of 1.5-3.5Pa.s at shear rate of 20/s.
Plastic viscosity is used to determine pumping characteristics, filling of rough surface,
coating and sensory character of chocolate mass (Goncalves, 2010). Viscosity is closely
related to particle size distribution, composition and processing strategy. The larger the
particle would result a lower viscosity as well as lower yield value (Albrecht et al, 2011).
Both viscosity and yield value are temperature dependant, but an increase in temperature
would result viscosity to decrease and yield value to rise (Anton Paar).

Fig 6. Relationship between viscosity and shear strees in production of chocolate
Viscosity is parallelly connected with yield value based on the Casson parameters
(Kutschmann,2000). Once the yield value is passed, the chocolate will behave like solid. As
shear stress increases, the structure effects get further developed resulting decreasing in
viscosity until a shear-stress equilibrium structure is reached. As drawn in Fig.5 at 1, the
viscosity reaches its minimum value min approximately 0.5 2 Pa.s and the chocolate
structure is completed. When being further processed, agglomerate structure would occur
resulting the chocolate to collapse.





13

Microstructural characterisation of coffee bean using X-Ray Microtomography
The most important parameters during roasting in the coffee processing is the microstructural
appearance of beans (Schenker, et al, 2000). By studying the change of coffee beans
structure, the taste of coffee produced can be modified. Not only type of coffee beans used as
raw materials, previous studies has shown that quality of coffee can also be improved by
modifying temperature in which the bean is processed (Clarke and Vitzthum, 2001). Roasting
is an essential process which need to be done in order to physically treat beans by heating it at
temperature up to 250C (Illy and Viani, 1995). Roasting also affects mechanical properties of
the coffee beans. The process of roasting is known to produce beans which are characterized
to have crispy texture and apparantly more fragile in structure (Pittia et al, 2001). The crisp
resembles low water content in the beans which cause a decrease on its density and is often
used as parameter in the presence of microspores (Schenker et al, 2000).
Pittia et al, 2001 believed that heat reactions determine changes in chemical, chemical-
physical and structural properties of coffee beans which affect the characteristic, taste and
texture of coffee. Phenomena of heat transfer along with degassing in the process of roasting
combined together with gas adsorption capacity are factors that mainly govern by coffee
beans structural properties in focus to the change of pore structure.
There are several techniques which can be applied to characterize coffee structure such as
light microscopy, scanning and cryo scanning electron microscopy (Huang et al, 2002). The
most favorable innovation which is commonly applied in industry is the application of 3D
imaging analyzes, the X-ray microtomographs. By using these mechanical tools, it would be
easier and more accurate to analyze beans microstructural characteristics such as porosity,
thickeness and the morphology of beans.
In the application of microtomography, there are two devices mostly found in the industry
which are synchroton radiaton X-ray microtomographs and dekstop X-ray microtomographs
(Goel et al, 2001). Comparing to those two types of microtomographs, synchrotons is a more
conventional method applied due to its limitation on the intensity. Synchrotons also uses
polychromatic fan beams resulting on low resolution images therefore it would be hard to
investigate in greater detail (Goel et al, 2001, Huang et al, 2002).
Desktop microtomograph is constantly developed in recent years and produces synchrotons
X-ray microtomograph. Synchrotons X-ray microtomograph on the other hand, can produce a
14

monochromatic parallel beam which results a higher intensity, leading to a higher resolution
images that are suitable for characterisation of detailed structured material (Samuelsen et al,
2001). According to Samuelsen et al, 2001, this method is widely used in clinical diagnosis
especially related to medical application, material science, geology and biology but recently it
also has been widely used in the study of food microstructure.

How does X-Ray Microtomography works?
Comparing to other characterization technique, X-ray microtomography can be considered as
a new method invented in the late 1870 (Sasov, 1987). This technique enables visualisation of
samples structure in three dimensional and it is believed to be a non-destructive method
which means during preparation of the sample, it does not need to undergo series of processes
which might disturb samples structure (Sasov et al, 1998). X-ray microtomography is
functioned based on how the X-ray beams interact with the sample provided. X-ray light will
be weaken as it passes through a sample. The decrease on the light intensity depends on the
density and atomic number of the sample (in this case the coffee bean) and the use of X-ray
energy. A reconstruction of the sample can be drawn by using images of the sample projected
from different angles. Supported by mathematical calculation, X-ray microtomography
creates cross sectional images of the internal structure of the object. When these different
consecutive slices are reconstructed a 3D visualization can be obtained with high resolution.

Fig 7. Schematic of the x-ray microtomography device (Davis et al, 2002)

As it can be seen from fig 6 a beam of monochromatic X-ray illuminates a sample placed in
front of a phosphor plate. A phosphor plate, in this case, is function to convers light to optical
radiation with high resolution (Davis et al, 2002). The intensity of X-ray light is recorded by
a digital, electro-optic detector while the projections of the sample are recorded by a CMOS
15

(complementary metal-oxide semiconductor) flat panel detector with an integated scintilator.
These projections are used to reconstruct three dimensional (3D) models of the observed
sample. Then two dimensional (2D) slices can be cut through the 3D models in different
directions. According to (Dalen, 2000), this method offers possibilities to attain resolution
until micrometer scale depending on the size of the sample being studied. X-ray
microtomography is often used to characterize highly porous material and composite
materials due to its ability to provide detail information about the density profile of the
sample, pore texture (pore density and pore size distribution), defect and dimensional
measurements (Proudhon, 2010).


(a) (b)
Fig 8. (a). Grey scale tomography of coffee bean
(b). 3D reconstruction of coffee beans using microtomography
(Frisullo, 2012)

Advantages and Disadvantages of X-Ray Microtomography
The main advantage of tomography is its three dimensions result produced in high resolution
whereas other methods only able to construct structures of sample onto a two dimensional
image. Three dimensional structures becomes very useful allowing for better observation
when studying human tissue (Barbetta, 2012). Microtomograph is excellent for bone imaging
with good resolution which can be up to 6m when combined with contrast agent. It is also
decent in terms of image acquisition times, which can be in the range of minutes for small
animals ( Koo, 2006). One of the major drawbacks of microtomograph is the radiation dosage
placed on test animals. Although this is generally not lethal, the radiation is high enough to
affect the immune system and other biological pathways which may ultimately change
experimental outcomes (Boone,2004). Also, radiation may affect tumor size in cancer model
as it mimics radiotherapy and thus extra control groups might be needed to account for this
16

potential variable. In addition, the contrast resolution of microtomography is quite poor and
thus it is unsuitable for distinguishing between similar tissue type such as normal vs diseased
tissues (Mizutani and Suzuki, 2010).
X-ray microtomography is believed to be an efficient technique and prove helpful for
identifying organic gem materials, corals and ivory, however it cannot be used to identify
sample with metal layers (Karampelas, 2010). In addition, microtomography instrumentation
is still very costly and yet it still requires technique to scientifically trained staff for analysis
and interpretation.
Other techniques that are used to characterise coffee
In application, the roasting process must be situated in an optimum condition paying
particular attention to the degree of roasting in order to produce coffee product as desired Illy
and Viani, 1995). Degree of roasting is an important parameter in coffee roasting in order to
determine the flavour of coffee product based on the coffee flavour profile as seen in fig 8.
The differences in texture, porosity and taste of coffee are likely to be resulted due to
different temperature which would lead to the change in degree of roasting.

Fig 9. Flavor by roast degree
Degree of roasting can be determined by visual observation and analytical methods. Visual
observation includes judging the coffee bean through its colour change during the process.
Although its a less accurate mechanism, but this method is commonly done in rural area.
Another way to identify degree of roasting is by listening to the cracking sound resulted
during roasting. There are two cracks that would likely to occur during roasting, at about 200-
202 C which identifies the beginning of light roast and another crack occurs at 224-226 C
(Wang, 2012).
17

Analytical methods is believed to be a more accurate way in quantifying the degree of roast.
This method includes the use of gas chromatography - mass spectrometer to measure ratio of
free amino acids (Nehring & Maier, 1992) and alkylpyrazines (Hashim&Chaveron, 1995)
and GC-MS with stable isotopes as internal standard (SIDA) for calculating the chlorogenic
acid content inside the roasted coffee beans (Illy & Viani, 1995).
Gas chromatography with mass spectrometer is a reliable analytical instrument in where
seperation, identification and quantification of components can occur continously at the same
time (Hajslova and Cajka, 2007). Gas chromatography is functioned to seperate compounds
into various components and the mass spectrometer does the analysis of the components.

Fig 10. Gas chromatography-mass spectrometer
According to Sparkman, et al (2011), the process starts by mixture of molecules is injected to
the GC. The sample is carried by helium, heated until it become gases. Chemical is then
separated in the column based on their volatility. After being separated, molecules are then
blasted with electrons which causes them to break up into ions. As ions continue through the
mass-spectrometer, they travel through an electromagnetic field that filters the ions based on
mass. The filter continously scans through the range of masses as the stream of ions come
from the ion source. The number of ions that passes through is measured by using a detector
to create a mass spectrum and information is then sent to computer to be analyzed.
Meanwhile, despite all its advantages gas chromatography-mass spectrometer has several
disadvantages which is the presence of disturbance in the mass spectrum (Gohlke and
McLafferty, 1993). This is occured due to unproper separation of gas chromatography which
results impurities to enter the mass spectrometer. This problem can be encounter by using
GC-MS with stable isotopes as internal standard (SIDA) although it will cost slightly more
expensive to purchase the isotopes required (Pickard, et al, 2013).
18

Other physical methods such as scanning electron microscopy (SEM), transmission electron
microscopy (TEM), cyro-scanning electron microscopy which have been widely used to
determine characteristic of roasted coffee beans especially regarding to its porosity and
changes of structure (Massini et al., 1990). The drawback of those methods is that it requires
complicated sample preparation. Before being analysed, the sample needs to be freezed or
dehydrated hence it would affect on the change of structure in certain types of product
(Frisullo, 2012)

(a) (b)
Fig 11. (a). TEM micrograph of a cell wall in a coffee bean
(b). Cryo-SEM micrograph of coffee bean tissue (Schenker, 2000)

The effect of microstructure to the texture and physical appearance of coffee products
The unique characteristic of food product are defined by many aspects and mostly observed
by the product appearances. Coffee for example, physical characteristics of coffee product is
closely related to how coffee bean is being treated. Size, shape and colour are important
parameter which has been commonly used to grade dry beans (Illy and Viani, 1995).
However, coffee beans have a porous, spongy texture therefore they are vulnurable of fungi.
Infected beans would result an off-flavour, strong smell and decrease in quality if the bean is
too moist (Sivetz, 1991).
According to Dutra, et al. 2001, the taste and texture of coffee product is likely to have
developed during the roasting steps. During roasting, beans is treated through series of
processes where chemical and physical changes is likely to occur (Dutra, et al, 2001).
Temperature and heat transfer factor becomes important in determining the characteristic of
coffee beans and it must be maintain in a constant condition to prevent beans from burning.
Commonly, time-temperature profile graphs is used to condition coffee bean roasting process
in order to develope a unique flavour desired. (Buffo and Cardelli-Freire, 2004).
19

Beans which are infected by environmental condition (such as immature beans, split in beans,
beans damaged by insect) also plays important role in determining the flavour of roasted
beans. Non damaged beans are heavier in weight comparing to faulty beans and believed to
havea a higher water activity (Mazzafera, 1994). Due to higher water content, non faulty
beans takes a longer time for the first crack to occurs.
Coffee are commonly categorized as light, medium or dark roast based on the heat process.
On different level, coffee beans tends to result specific flavor and different appearances as
stated in table 2. A sour and underdeveloped flavour is commonly found during light roast
level which is indicated by the first crack. Further heat treatment results a first crack is known
as medium level. During this level, sweated process occurs producing a bright brown
coloured coffee with well-balanced taste. When roasting continuous, dark roast level occurs
resulting low acidity and a shiny coffee beans (Lyman et al, 2003).
Table 2. Roast level and their flavors
Notes Surface Flavour
Light
During this stage, a pop
sound is heard or known as
the first crack. It occurs due
to the rise of temperature in
coffee bean.
Dry
High acidity is achieved during this
process and the weigh of bean is
decreasing due to water being
vaporized.
Medium
Following the first crack, the
roast level reaches its
medium phase.
Dry
Caramelisation of sugar occured and
the level of acidity is decreasing. It
produce a larger bean in shape.
Dark
In this phase, another pop
sound is released and the
bean become very oily. This
phase is called the second
crack.
Shiny
The flavour is more bittersweet and it
smells like roasted bean.



20

Microstructural characterisation of thin films using Spectroscopic Ellipsometry
Measurement of thin film has been a challenge for past several years but the problem has
been solved with the innovation of light analysis technique known as spectroscopic
ellipsometer. Spectroscopic ellipsometer is a tool which enables measuring optical constant
(extinction coefficient and refractive index) of film structures as well as calculating film
thickness of thin film (Horiba). Spectroscopic ellipsometer is generally used to measure
materials such as semiconductor thin films, dielectric gates, dielectric films like YSZ,
characterisation of photoresist in UV, optical coating thermal barrier coating with YSZ thin
films for turbo reactor blades, self-assembled monolayer, chemistry-polymer thin films,
optical components like mirrors, coating and LCD displays (Jasco). Due to its sensitivity to
very thin layers, this analytical method is commonly applied in measuring very thin layers
ranging from 1 A to 1micron (Laughlin, 2005). Ellipsometer is designed with two different
polarization measurements allowing twice much information therefore a more accurate
analysis can be produced (Hiroyuki, 2007). Ellipsometer can also be set at variety of
incidence angles resulting an increase amount of data which will be used for analysis.

Fig 12. Measurement principle of ellipsometry
How does Ellipsometry works?
Ellipsometry works by lighting sample with a parallel beam of monochromatic light being set
to a variable angle of incidence. The change of polarisation after the light is reflected from
the surface of sample is analysed using polarisation-sensitive analyser (Pascu, 2009). From
the change of polarisation, measurement of optical parameters from the sample is carefully
conducted. On the other hand, variable angle of spectroscopic ellipsometry is used to
determine optical constants which are refractive index and extinction coefficient through the
reflection of light beam from the surface of the sample (Rothen, 1974). Refractive index (n)
represents the propagation speed of the wave through the sample and direction of propagation
while extinction coefficient (k) relates to how much energy of the wave is absorbed in a
material (Den Boer, 1995). Refractive index and extinction coefficient is then modelled
21

through computer software in order to calculate thickness of single layer. By processing data
from many points on the sample, it is then able to generate two dimensional and three
dimensional sample surface.
There are three most common used ellipsometer applied in the industry for characterisation of
thin films (Tompkins, 2005). Those elipsometer differs in term of polarizer system and
analyser, also the source of beam from the light is coming. The basic design of ellipsometer
are nulling ellipsometer, rotating analyser and photo elastic modulator ellipsometer.
Comparing those three ellipsometer designs, the most simplest design used is the nulling
ellipsometer (Nulling Ellipsometry). Although the disadvantages when this method is being
applied are the optical component is set to a specific wavelength and it cannot be modified.
Also due to the measurement which occurs in real time, a minor mistake would affect the end
of calculation resulted.

Fig 13. Nulling ellipsometer
Rotating analyser ellipsometer is the oldest most-commercially used equipment in the
industry. Similar to other types of ellipsometer, this tool uses linearly polarized incident light
reflected from the sample to analyse the thickness of thin film. The only difference is that the
polarisation analyser is a rotating analyser, which is used as a detector to measure output
intensity as a function of polarization angle (Chen, 1987). Rotating analyser ellipsometer is
favourable because it is a less time consuming process and relatively easy to control being
compared to nulling ellipsometer and photo elastic modulator ellipsometer.

Fig 14. Rotating analyzer ellipsometer
22

Photo elastic modulator is a new innovation of ellipsometer developed. Due to the ability of
not requiring any moving parts to get the data, this ellipsometer is known as solid state
ellipsometer. Photo elastic modulator works as programmed by computer and easier to
control electronically by using a remote. PEM produces light beam, polarized at 50 kHz and
it is well-equipped with static analyser allowing the light to reflected from the sample surface
into detector and generated signal from it (Hinds Instruments).

Fig 15. Photo elastic modulator ellipsometer

Calculation of Film Thickness by using Spectroscopic Ellipsometer

Fig 16. Ambient film substrate system (Pedersen, 2004)
Thickness of the film can be calculated when measurement are done in three system as drawn
in fig. 15 keeping in mind that the refractive indexes in all media are known. When the light
from ellipsometer hits the surface at ambient, o is created. As it continues its way down to
film and substrate, it created the angle of reflection of 1 and 2. Based on method of
calculation in ellipsometry written by Pedersen, (2004), the angle of reflections are then used
to calculate reflection coefficients using equation of 2.a and 2.b
P =

. (2.a)
P =

.. (2.b)
23

Equation 2.a and 2.b is then inserted in complex reflection ratio equation given in 2.c to find
the value of P (Azzam & Bashara, 1977, p.288). Once P is found, further calculation is done
to determine the value of refractive index (X) using equation 2.d. Refractive index is related
to the film thickness stated in equation 2.e
P = P .

(2.c)
P =

. (2.d)
Where A = ; B = ; C = ;
D = ; E = ; F =

ln (X) = - j.4

() .. (2.e)
d =
()


If a set of ellipsometric parameters are measured at a given angle of incidence and a given
wavelength with the thickness of film is the only unknown, thus the thickness of a sample can
be calculated.
Advantages and Disadvantages of Spectroscopic Ellipsometry
The use of ellipsometry is believed to be a non destructive technique because it requires
uncomplicated sample preparation. This method is also favorable due to less time consuming
process and ease in operation (Collins, 1990). Other advantages of spectroscopic ellipsometry
is that it is very sensitive, can be applied in both measuring single and multi layer film and
also has the capability to measure ultra thin films as thin as 1 Amstrong (Morton, 2002).
Direct measurement of optical constant (extinction coefficient and refractive index) can be
achieved in a more accurate manner compared to other analytical methods. Despite all the
advantages, spectroscopic ellipsometry has some drawbacks as well such as significant
change in temperature during the process would cause an error to the result. This process also
requires variety of voltages to be applied for different wave length Pascu, 2009. Technical
difficulties are also found when characterizing thin films which is thinner than 10 nm since it
would be hard to differentiate between layer and substrate and also on thick films since there
is interference oscillation which is difficult to resolve . Spectroscopic ellipsometry is a very
sensitive device that thin film being observerd must be uniform in thickness to get a more
accurate measurement and reducing error in the result. Another factors that needs to be
24

carefully watched is the roughness of the film. To achieve accurate calculation, thin films
must be smooth to prevent light from depolarized (Den Boer, 1995).
Other techniques that are used to characterise thin films
There are several techniques which can be applied to characterise thin films especially in
measuring the thickness of film. One of the most commonly used and cheap in application is
spectroscopic reflectance. This method has been widely used to measure the thickness,
roughness and optical constant of thin films. Film thickness of 10A-100A can be measured
by spectral reflectance by varying the wavelength of reflectance (Filmetrics,2005). However,
when films are too thin, too numerous or to complicated to be measured, this method would
result inaccuracy and error to the system. In the industry, spectral reflectance is often used to
measure SiO2 on silicon (Hlubina, 2009).
Other method used as thin film measurement techniques is X-ray reflectivity (XRR). This
method is believed not only able to determine thin film thickness but also other film
parameters such as density, surface, interface roughness and can be used to analyze the layer
structure of film. According to Yasaka, 2010, X-ray reflectivity measurements were
performed using X-ray diffractometer. A rotating anode Cu was used along with the X-ray
beam was monochromatized using monochromator. The incident and reflected beams were
collimated and the reflection intensity was measured by a scintillation counter. Thickness and
roughness determination is needed to be done in high accuracy therefore it is essential to
precisely align a sample position to the X-ray beam (Inaba, 2008). The sample is mounted on
a vertical sample stage and allignment is done automatically via computer.
The effect of microstructure to the texture and physical appearance of thin films
When thin films are analyzed, the most important factor that needs to be considered
particularly related to the microstructure of the film itself because a slight change in the
formation of microstructure often result a significant change to the thin films properties. The
effect of change in microstructure would affects mechanical properties of thin film such as
hardness and plasticity properties (Bull, 2012). Experiment conducted by Bull focuses on the
affect of grain size to the hardness of thin films. His investigation resulted that smaller grain
size of film leads to a harder film. The hardness of film increases in the experiment as the
grain size decreases but the hardness of thin film remains constant when large grain size is
being observed.
25

Furthermore, the hardness of thin films plays an important role on determining its plasticity
properties. Yong (2005) observed the affect of microstructural changes of thin films towards
films plasticity properties. Plasticity properties of film occurs due to annealing process.
Prior to annealing process, the stress strain curves shows changes from elastic to plastic
behaviour. This transition can affect to diversity of stress between grains.
Due to heat treatment dring annealing process, it results a decrease in the thickness of the
films (Naceur, 2012). Thicker films is believed to have a more step by step progress from
elastic to plastic behavior when compared to films which are thinner in height because thicker
films have a wider grain size distribution (Yong, 2005). When comparing films wih similar
thickness, a more significant transition is seen in all films due to annealing. As the thickness
of film decreases, the yield stress increases a little but it soon drops significantly after the
process of annealing. After the process of heating, when the temperature of film is cooled
down, thermal transfer occur in the film and substrate. Heat transfer resulted development of
tensile stress to occur in grains hence a full plastic flow is resulted. Thus immediately after
cooling, all grains are roughly at their yield stress. The same yield stress is caused by stress
relaxation and elastic anisotropy of the grain. Macroscopically, this results in a sharp
transition of the stress-strain curve from the elastic regime due to plastic regime.










26

References:
How laser diffraction works. [Online], : 26/02/2014. Available
from: http://www.pharmacopeia.cn/v29240/images/v29240/c429-f1.gif.
A. Sasov and D. Van Dyck (1998) Dekstop X-ray microscopy and microtomograpy. Journal of
microscopy, 191 151-158.
Afoakwa, E. and Paterson, A. (2008) Effect of particle size distribution and composition on
rheological properties of dark chocolate. . 226 1259-1268.
Chocolate A functional food? . [Online], : 1/3/2014. Available
from: http://ianrpubs.unl.edu/live/hef599/build/hef599.pdf.
Determining the yield point and viscosity of chocolate. Application Note RheolabQC food. .
[Online], . Available from: http://www.mep.net.au/foodlab/FL_7/AN_RLQC_Choco_B.pdf.
Barbetta, A., Bedini, R., Pecci, R., et al. (2012) Role of X-ray Microtomography in Tissue
Engineering. 48 (1): 10-18.
Boone, J. and Velazquez, O., Cherry SR. (2004) Small-animal X-ray dose from micro-
CT. . Molecular Imaging, 3 (3): 149-158.
Buffo, R.A and Cardelli-Freire, C (2004) Coffee flavour: an overview. Flavour and Fragrance
Journal. 19 (2): 99-104.
Bull, S.J., Sanderson, L., Moharrami, N., et al. (2012) Effect of microstructure on hardness of
submicrometre thin films and nanostructure devices. 28 (9): 1177-1185.
Chen, L.Y. and Lynch, D.W. (1987) Scanning ellipsometer by rotating polarizer and
analyzer. Applied Optics, 26 (24): 5221-5228.
Clarke, R.J. and O.G. Vitzthum (2001) Coffee: Recent Developments. Oxford, United Kingdom:
Blackwell Science.
Collins, R.W and Kim Y.T. Ellipsometry for Thin-Film and Surface Analysis. Analytical
Chemistry, 62 887-900.
Comparison of Particle Sizing Methods. [Online], : 1/3/2014. Available
from: http://www.cpsinstruments.eu/pdf/Compare%20Sizing%20Methods.pdf.
Dalen, G., Nootenboom, P., Don, A. and Blonk, J. (2000) Determination of bubbles in foods by
X-ray microtomography and image analysis. Unilever Research & Development.
Davis, G., Dowker, S., Elliot, J., et al. Non-destructive 3D Structucal studies by X-Ray
Microtomography. JCPDS-International Centre for Diffraction Data., 45.
Den Boer, J. (1995) Spectroscopic Ellipsometry: Components, Calibration and Application.
PhD Thesis. Department of Physics. Eindhoven University of Technology, Eindhoven
University of Technology.
Do, A., Hargreaves, M., Wolf, B., et al. (2007) Impact of Paricle Size Distribution on Rheological
and Textural Properties of Chocolate Models with Reduced Fat Content. 72 1750-1757.
Dutra, E.R., Oliverira, S., Franca, A.S., et al. (2001) A preliminary study on the feasibility of using
the composition of coffee roasting exhaust gas for the determination of the degree of
roast. Journal of Food Engineering, 47 241-246.
27

El-kalyoubi, M., Khallaf, M., Abdelrashid, A., et al. (2011) Quality characteristics of chocolate
containing some fat replacer. Annals of Agricultural Sciences, 56 (2): 89-96.
Flavor by roast degree. [Online] : 22/3/2014. Available from: http://www.coffeeanalysts.com/wp-
content/uploads/2010/05/flavoraromachangesbyroastdegree.jpg
Frisullo, P., Laverse, J., Barnaba, M., et al. (2012) Coffee beans microstructural changes induced
by cultivation processing: An X-ray microtomographic investigation. Journal of Food
Engineering, 109 175-181.
Thin film Measurement.. [Online], : 1/3/2014. Available
from: http://institute.ntb.ch/fileadmin/Institute/MNT/pdf/Filmetrics_advanced%20thin%20film%2
0measurement.pdf.
Gas chromatography mass spectrometry. [Online] : 20/3/2014. Available from:
http://www.fao.org/docrep/009/a0691e/A0691E09.gif
Gaikwad, V. (2012) Oral Processing of Dark and Milk Chocolate. Master of Technology in Food
Technology, the Riddet Institute, Massey University, Palmerston North, New Zealand.
Goel, A., Tzanakakis, M., Huang, S., et al. Characterization of three-dimensional structure of paper
using X-ray microtomography. Tappi Journal, 84 (5): 72.
Gohlke, R. and McLafferty, F. (1993) Early Gas Chromatography/Mass Spectrometry. . Journal of
the American Society for Mass Spectrometry., 4 (5): 367-371.
Goloshevsky, A., Walton, J., Shutov, M., et al. (2005) Nuclear magnetic resonance imaging for
viscosity measurements of non-Newtonian fluids using a miniaturized RF coil. Measurement
Science and Technology,16 513-518.
Goncalves, E. (2010) Chocolate Rheology. Cienc.Technol.Aliment, 30 (4): 845-851.
Graham, M. (2003) The Coulter Principle: Foundation of an Industry. Journal of the Association
for Laboratory Automation, 8 (6): 72-81.
Hajslova, Jana and Cajka, Tomas. (2007) Gas chromatography mass spectrometry (GC-MS).
Chapter 12. Food Toxicants Analysis. Pp 419-473. Food Toxicants Analysis, 12 419-473.
Hashim, L and Chaveron, H. (1995) Use of methylpyrazine ratios to monitor the coffee roasting
. Food Research International, 28 (6): 619-623.
PEMs in Ellipsometry. [Online], : 4/3/2014. Available from: http://www.hindsinstruments.com/wp-
content/uploads/PEMs_in_Ellipsometry1.pdf.
Hiroyuki, F. (2007) Spectroscopic Ellipsometry Principles and Applications. West Sussex,
England: John Wiley&Sons Ltd.
Hlubina, H., Ludacek, J. and Ciprian, D. The effect of silicon substrate on thicknes of SiO2 thin film
analysed by spectral reflectometry and interferometry. Applied Physics, 95 795-799.
(2010). Jasco Semiconductor Solutions. [Online], : 24/2/2014. Available
from: http://www.jasco.com.br/imagem/catalogos/semicondutor_01.pdf.
Spectroscopic Ellipsometry. [Online], : 24/2/2014. Available
from: https://www.horiba.com/scientific/products/ellipsometers/downloads/ellipsometry-
brochures-downloads/.
28

Huang, S., Goel, A., Ramaswamy, S., et al. (2002) Transverse and in-plane pore structure
characterisation of paper. Appita Journal, 55 (3): 230-234.
Illy, A. and Viani, R. (1995) Espresso Coffee: The Chemistry of Quality. Vol. 2 San Diego:
Academic Press Limited.
Inaba, K. (2008) X-ray thin film measurement techniques.
. The Rigoku Journal, 24 (1):.
Interference and Diffraction. [Online], (14): 4/4/2014. Available
from: http://web.mit.edu/viz/EM/visualizations/coursenotes/modules/guide14.pdf.
Karampelas, S., Michel, J., Zheng-Cui, M., et al. X-Ray Computed Microtomography Applied to
Pearls: Methodology, Advantages and Limitations. Gems & Gemology. 46 (2): 122-127.
Kippax, P. (2005) Appraisal of the laser diffraction particle sizing technique.Malvern
Instrument Ltd.
Koo, V., Hamilton, P. and Williamson, K. (2006) Non-invasive in vivo imaging in small animal
research. . Cellular Oncology, 28 127-139.
(2000). Viscosity Measurement on Liquid Chocolate with the VT550. [Online], 97 (136):
27/02/2014. Available from: http://m.rhl.pl/files/17736/Pomiary_lepkosci_plynnej_czekolady.pdf.
Laughlin, D., Kumar, S. and Peng, Y. Engineering the microstructure of thin fils for perpindular
recording. IEEE transactions on magnetics, 41 (2):.
Lyman, D., Benck, R., Dell, S., et al. (2003) FTIR-ATR Analysis of Brewed Coffee: Effect of
Roasting Conditions.
. Journal of Agricultural and Food Chemistry, 51 (11): 3268-3272.
Malvern (2011) Empirical methods for estimating refractive index values MRK843-
01Malvern Instrument Ltd.
Malvern (2010) Mastersizer2000. MRK 1308-01: United Kingdom: .
Malvern (2008) Rapid refractive index determination for pharmaceutical actives MRK 529-
03Malvern instrument Ltd.
Mazzafera, P., Crozier, A. and Sandberg, G. (1994) Studies on the metabolic control of caffeine
turnover in developing endosperm and leaves of Coffeearabica and C.dewevrei. . Journal of
Agricultural Food Chem., 42 1423-1427.
Measurement principle of ellipsometry. [Online], : 25/3/2014. Available from:
http://www.foi.se/surfbiotech/tt/img00023.gif
X-ray microtomography in Biology. [Online], : 27/2/2014. Available from: http://www.el.u-
tokai.ac.jp/ryuta/Micron43(2-3)104-115(2012)preprint.pdf.
Mohos, F. (2010) "Part 2. Physical operation" In Confectionery and Chocolate Engineering:
Principles and Applications Oxford, United Kingdom: Wiley Blackwell. pp. 243.
(2002). Optical Monitoring of Thin-films Using Spectroscopic Ellipsometry. [Online], : 2/4/2014.
Available from: http://www.dentonvacuum.com/uploads/pdfs/DV-
WP018_spectroscopicellipsometry.PDF.
Naceur, B., Gaidi, M., Bousbih, F., et al. Annealing effects on microstructural and optical properties
of nanostructured TiO2 thin films. Current Applied Physics, 12 (422): 428.
29

Nehring, UP and Maier, H. G. Indirect determination of the degree of roast in coffee. Zeitschrift
fr Lebensmitteluntersuchung und -Forschung, 195 (1): 39-42.
Nulling ellipsometry. [Online], : 22/3/2014. Available from:
http://www.fis.unipr.it/~gigi/elli/Image23.jpg
Pain, H.J. (2005) "Waves in Optical System" In The Physics of Vibrations and Waves 2nd ed.
West Sussex, England: John Willey & Sons Ltd. pp. 267-297.
Pascu, Rovena and Dinescu, Maria. (2012) Optical Characterization at Thin Films with
Spectroscopic Ellipsometry Method. PhD Thesis. Scientific Report. Romanian Reports in
Physics, 64 (1): 135-143.
(2004). Ellipsometry. [Online], : 5/3/2014. Available
from: http://homes.nano.aau.dk/kp/Ellipsometry/main.pdf.
Pickard, S., Irina Becker, Merz, K., et al. (2013) Determination of the Alkylpyrazine composition of
coffee using stable isotope dilution gas chromatography mass spectometry (SIDA-GC-
MS). . Agricultural Food Chemistry, 61 (26): 6274-6281.
Pittia, P., Rosa, M. and Lerici, C. (34) Textural Changes of Coffee Beans as Affected by Roasting
Conditions. Food Science and Technology, 3 168-175.
Photoelastic modulator ellipsometry. [Online], : 12/7/2014. Available from:
http://www.horiba.com/typo3temp/pics/e6fbcbe3b1.jpg
Powis, T., Cyphers, A., Gaikwad, N., Grivetti, L. and Cheong, K. (2011) "Cacao Use and the San
Lorenzo Olmec", Proceedings of the National Academy of Sciences of the United States of
America 12 Januari 2011 pp. 85958600(10.1073/pnas.1100620108).
Proudhon, H. (2010) "Using X-ray micro-tomography to probe microstructure and damage of
structural materials", 21 -25 Juni Paris: Centre des Materiaux, Mines Paris Tech .
Rothen, A. (1974) Ellipsometric Studies of Thin Films. Progress in Surface and Membrane
Science, 8 81-118.
Rowat, A., Hollar, K. and Rosenberg, D. (2011) The Science of Chocolate: Interactive Activities on
Phase Transition, Emulsification and Nucleation. 88 121-129.
Samuelsen, E., Gregersen, . W., Houen, P.-J., Helle, T., Raven, C., and Snigirev, A. (2001)
Three
Dimensional Imaging of Paper by Use of Synchroton X-Ray microtomography
. Journal of Pulp and Paper Science, 27 (2): 50-53.
Sasov, A. (1987) Microtomography. 147 169-192.
Schenker, S., Handschin, S., Frey, B., et al. (2000) Pore Structure of Coffee Beans Affected by
Roasting Condition. Food Engineering and Physical Properties., 65 (3):.
Schenker, S., Heinemann, C., Huber, M., et al. (2002) Impact of Roasting Conditions on the
Formation of Aroma Compounds in Coffee Beans. Journal of Food Science, 67 (1): 60-66.
Sivetz, M and Desrosier, NW (1985) Coffee technology. Vol. 2 London: Elsevier Applied Science
Publisher.
Sparkman, David., Penton, Zelda., Kitson, Fulton. (2011). Gas Chromatography and Mass
Spectromety a practical guide. second edition. ISBN: 978-0-12-373628-4. Elsevier Inc.
30

Tompkins, H.G and Irene, E.A. (2005) Handbook of Ellipsometry
. New York: William Andrew Publishing.
(2005). Technical Release Note. Principles of Nulling and Imaging Ellipsometry. Nanofilm
Technologie. [Online], 1 : 5/3/2014. Available
from: http://www.fisica.unam.mx/liquids/images/tutorials/principle.pdf.
Wang, N. (2012) Physicochemical Changes of Coffee Beans during Roasting. Master of
Science in Food Science, University of Guelph, Canada.
Wichchukit, S. (2004) Rheological Property Studies of Confectionary Products using
Conventional Viscometries and Tomographic Viscometry.Doctor of Philosophy, University of
California Davis.
Wichchukit, S., McCarthy, M. and McCarthy, K. (2005) Flow behavior of milk chocolate melt and
the application to coating flow. . Journal of Food Science., 70 (3): 165-171.
(2006). What makes a smooth, creamy chocolate? [Online], (American Institute of Physics).
Available from: http://www.dfi.uchile.cl/~rsoto/docencia/FluidosNoNewton2008/Chocolate.pdf.
[Accessed 25/2/2014].
Xiang, Y. (2005) Plasticity in Cu thin films: an experimental investigation of the effect of
microstructureDoctor of Philosophy, Harvard University, Cambridge.
Yasaka, M. (2010) X-ray Thin Film Measurement Techniques. The Rigoku Journal, 26 (2).

Das könnte Ihnen auch gefallen