Sie sind auf Seite 1von 4

System Setup information: http://support.netapp.

com/NOW/public/system_setup/
Data ONTAP 8 library: http://support.netapp.com/documentation/productlibrary/index.html?productID=30092
Licenses: http://support.netapp.com/eservice/agree.do?moduleName=PROTOCOL
Controller and confguration examples; Universal SAS and ACP Cabling Guide: https://library.netapp.com/ecm/ecm_download_fle/ECMM1280392
OnCommand System Manager documentation set: http://support.netapp.com/documentation/productlibrary/index.html?productID=61372
Data ONTAP Express Guides for your version of Data ONTAP: http://support.netapp.com/documentation/productlibrary/index.html?productID=30092
HELPFUL LINKS
Visit the NetApp web site for more information.
Complete System Setup (Choose option A or B below)
4
Complete confguration
5
Create an account and register your system.
Get your license keys.
Register at support.netapp.com 1
Provision more storage.
Confgure other protocols, data protection, and AutoSupport.
Set up Service Processor and Remote Support Agent.
Download OnCommand System Manager
From http://support.netapp.com/NOW/cgi-bin/software/
3
Download and run Confg Advisor
From http://support.netapp.com/NOW/download/tools/confg_advisor/
2
For Clustered Data ONTAP For 7-Mode, HA
5 1 2 3 4
4 1 2 3 5
Enter the values from the confguration
workbook worksheets when prompted by setup script.
Complete initial
network confguration
4
Complete confguration worksheets
From NetApp System Installation Workbook
https://feldportal.netapp.com;
search for "NetApp System Installation Workbook"
1
Power on all disk shelves,
check IDs, and then
power on the controllers.
3
ALL power supplies MUST be powered on.
A
B
1
2
LNK LNK
IOM6
I O M 6
LNK LNK
IOM6
I O M 6
DC AC
x2
2
DC AC
x2
2
Install System Setup software
Do not power on your system until directed
by System Setup software
Both power supplies MUST be powered on.
the system.
Wait for discover to complete.
Enter the values from the confguration worksheet
into System Setup.*
Complete confguration worksheet
From http://support.netapp.com/NOW/
public/system_setup/
1
Install and run System Setup software 4
*If you cannot use System Setup, see the Data ONTAP Software Setup Guide.
Power on all disk shelves ONLY
and check IDs
3
Cable Windows client to same
network as your controllers
2
2 4 6 8
1 3 5 7
10 12 14 16
9 11 13 15
12
11
14
13
16
15
6
5
8
7
10
9
2
1
4
3 1000/100/10M
LNK /
1000/100/10M
LNK /
MANAGEMENT SUBNET
WINDOWS CLIENT
VLAN
FAS8040/8060
SYSTEM
A B
N
e
t
A
p
p

s
u
p
p
o
r
t

s
i
t
e
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
Cable serial console
2
Prepare for installation (Choose option A or B below)
1
4 5 1 2 3
Installation and Setup Instructions
FAS8040 and FAS8060 Systems
Power cables
Confguration
worksheet
Storage,
starter network,
and 10 GbE cables
Power cables
Storage,
starter network,
and 10 GbE cables
Serial cable
For Clustered Data ONTAP For 7-Mode, HA A B
In the box: In the box:
Download: Download:
Microsoft Windows client
Runs the software to confgure
your storage system
Screwdriver
Additional network cables
For connecting your storage to your network
switch and Microsoft

Windows

client
Rack space - 6U
You provide:
Additional network cables
For connecting your storage to your network
switch and Microsoft

Windows

client
Screwdriver
Rack space - 6U
Serial console connection
Connection to DB9 serial console port
or USB-to-DB9 converter to laptop
You provide:
System Setup Software
http://support.netapp.com/NOW/public/system_setup/
OnCommand System Manager
http://support.netapp.com/NOW/cgi-bin/software/
NetApp System Installation workbook
https://feldportal.netapp.com;
search for "NetApp System Installation Workbook"
OnCommand System Manager
http://support.netapp.com/NOW/cgi-bin/software/
210-06179+A0
Single chassis HA with DS2246 disk shelves
Single chassis HA with DS424x disk shelves
Cable storage (Choose option A or B below)
3
B
A
For additional confgurations, see HELPFUL LINKS.
Network cables
2
1
3
4
Daisy chain SAS ports
Connect frst SAS ports
Connect last SAS ports
Connect ACP ports
on controllers to
the disk shelves and
shelf-to-shelf ACP ports
Storage cables
1 2 3
Network cables
2
1
3
4
Daisy chain SAS ports
Cable frst SAS ports
Cable last SAS ports
Cable ACP ports
on controllers to
the disk shelves and
shelf-to-shelf ACP ports
Storage cables
1 2 3
4 5 1 2 3
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
IOM6
I O M 6
LIN K
LIN K
IOM6
I O M 6
LIN K
LIN K
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
IOM6
I O M 6
LIN K
LIN K
IOM6
I O M 6
LIN K
LIN K
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
IOM6
I O M 6
LIN K
LIN K
IOM6
I O M 6
LIN K
LIN K
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
IOM6
I O M 6
LIN K
LINK
IOM6
I O M 6
LIN K
LINK
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
IOM6
I O M 6
LIN K
LINK
IOM6
I O M 6
LIN K
LINK
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
IOM6
I O M 6
LIN K
LINK
IOM6
I O M 6
LIN K
LINK
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
1
2
AC AC
IOM6
I O M 6
LIN K
LIN KIOM6
I O M 6
LIN K
LIN K
1
2
AC AC
IOM6
I O M 6
LIN K
LIN KIOM6
I O M 6
LIN K
LIN K
1
2
AC AC
IOM6
I O M 6
LIN K
LIN KIOM6
I O M 6
LIN K
LIN K
1
2
AC AC
IOM6
I O M 6
LIN K
LIN KIOM6
I O M 6
LIN K
LIN K
1
2
AC AC
IOM6
I O M 6
LIN K
LIN KIOM6
I O M 6
LIN K
LIN K
1
2
AC AC
IOM6
I O M 6
LIN K
LIN KIOM6
I O M 6
LIN K
LIN K
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
Install hardware
2
Rack the system.
Rail kit: follow instructions in the rail kit.
OR System cabinet: install in the system cabinet.
Place the bezel on the front of the system.
Install system 1
2
See your network administrator for help connecting to your switch.
Cable controller to switches and power (Choose option A or B below)
4 5 1 2 3
Two node switchless cluster, clustered Data ONTAP A Attach cable management tray. (Not shown)
10GbE Network cables
OPTION A: Cable the cluster interconnect
e0a to e0a and e0c to e0c ports on both
controllers.
OPTION B: Cable e0a through e0d
on both controllers to switch(es).
Network cables
Connect wrench ports to the
management switch.
Network cables
Connect GbE ports e0i and e0k
to GbE data network switches.
10GbE Network cables
Connect ports e0e|0e and e0g|0g
to data switch.
Strap the cables to the cable
management tray. (Not shown)
Power cables
Cable both power supplies
for each chassis.
ALL power cords MUST be used for all units.
1
3
2
5
6
7
4
Switched HA confguration (clustered Data ONTAP and 7-Mode)
B
OPTIONAL 2-POST
MID-MOUNT BRACKETS
LIFTING HAZARD CAUTION
125 lbs. (57 kg)
DO NOT power on system at this point.
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
TO MANAGEMENT
NETWORK SWITCH
3
TO MANAGEMENT
NETWORK SWITCH
3
2
TO SWITCHES
C-Mode: To cluster network switches
7-Mode: To data switch
7
2
7
TO DATA NETWORK SWITCHES 5
TO GbE DATA
NETWORK SWITCHES
4
TO DATA NETWORK SWITCHES 5
TO GbE DATA
NETWORK SWITCHES
4
FRONT VIEW OF SYSTEM
BACK VIEW OF SYSTEM
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
10 Gigabit Ethernet
ports (e0a-e0d)
10 GbE Ethernet ports (e0e-e0h) or
Fibre Channel ports (0e-0h) (SFP dependent)
Controller
attention LED
NVRAM
LED
A B
Bezel
SAS ports (4)
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
Gigabit Ethernet
ports (e0i-e0l)
Power LED
Attention LED
A B
Controller A and B
activity LEDs
A B
Console port
(Setting:
9600 N-8-1)
Remote/Node
Management port
(wrench icon)
ACP port
(locked wrench icon)
Slots for adapter cards Slots for adapter cards
Single chassis HA with DS2246 disk shelves
Single chassis HA with DS424x disk shelves
Cable storage (Choose option A or B below)
3
B
A
For additional confgurations, see HELPFUL LINKS.
Network cables
2
1
3
4
Daisy chain SAS ports
Connect frst SAS ports
Connect last SAS ports
Connect ACP ports
on controllers to
the disk shelves and
shelf-to-shelf ACP ports
Storage cables
1 2 3
Network cables
2
1
3
4
Daisy chain SAS ports
Cable frst SAS ports
Cable last SAS ports
Cable ACP ports
on controllers to
the disk shelves and
shelf-to-shelf ACP ports
Storage cables
1 2 3
4 5 1 2 3
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
IOM6
I O M 6
LIN K
LIN K
IOM6
I O M 6
LIN K
LIN K
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
IOM6
I O M 6
LIN K
LIN K
IOM6
I O M 6
LIN K
LIN K
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
IOM6
I O M 6
LIN K
LIN K
IOM6
I O M 6
LIN K
LIN K
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
IOM6
I O M 6
LIN K
LINK
IOM6
I O M 6
LIN K
LINK
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
IOM6
I O M 6
LIN K
LINK
IOM6
I O M 6
LIN K
LINK
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
N
3
1
4
2
Disconnect all supply power for complete isolation.
N
3
1
4
2
D i s c o n n e c t a l ls u p p l y p o w e r f o rc o m p l e t e i s o l a t i o n .
IOM6
I O M 6
LIN K
LINK
IOM6
I O M 6
LIN K
LINK
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
1
2
AC AC
IOM6
I O M 6
LIN K
LIN KIOM6
I O M 6
LIN K
LIN K
1
2
AC AC
IOM6
I O M 6
LIN K
LIN KIOM6
I O M 6
LIN K
LIN K
1
2
AC AC
IOM6
I O M 6
LIN K
LIN KIOM6
I O M 6
LIN K
LIN K
1
2
AC AC
IOM6
I O M 6
LIN K
LIN KIOM6
I O M 6
LIN K
LIN K
1
2
AC AC
IOM6
I O M 6
LIN K
LIN KIOM6
I O M 6
LIN K
LIN K
1
2
AC AC
IOM6
I O M 6
LIN K
LIN KIOM6
I O M 6
LIN K
LIN K
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
Install hardware
2
Rack the system.
Rail kit: follow instructions in the rail kit.
OR System cabinet: install in the system cabinet.
Place the bezel on the front of the system.
Install system 1
2
See your network administrator for help connecting to your switch.
Cable controller to switches and power (Choose option A or B below)
4 5 1 2 3
Two node switchless cluster, clustered Data ONTAP A Attach cable management tray. (Not shown)
10GbE Network cables
OPTION A: Cable the cluster interconnect
e0a to e0a and e0c to e0c ports on both
controllers.
OPTION B: Cable e0a through e0d
on both controllers to switch(es).
Network cables
Connect wrench ports to the
management switch.
Network cables
Connect GbE ports e0i and e0k
to GbE data network switches.
10GbE Network cables
Connect ports e0e|0e and e0g|0g
to data switch.
Strap the cables to the cable
management tray. (Not shown)
Power cables
Cable both power supplies
for each chassis.
ALL power cords MUST be used for all units.
1
3
2
5
6
7
4
Switched HA confguration (clustered Data ONTAP and 7-Mode)
B
OPTIONAL 2-POST
MID-MOUNT BRACKETS
LIFTING HAZARD CAUTION
125 lbs. (57 kg)
DO NOT power on system at this point.
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
TO MANAGEMENT
NETWORK SWITCH
3
TO MANAGEMENT
NETWORK SWITCH
3
2
TO SWITCHES
C-Mode: To cluster network switches
7-Mode: To data switch
7
2
7
TO DATA NETWORK SWITCHES 5
TO GbE DATA
NETWORK SWITCHES
4
TO DATA NETWORK SWITCHES 5
TO GbE DATA
NETWORK SWITCHES
4
FRONT VIEW OF SYSTEM
BACK VIEW OF SYSTEM
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
10 Gigabit Ethernet
ports (e0a-e0d)
10 GbE Ethernet ports (e0e-e0h) or
Fibre Channel ports (0e-0h) (SFP dependent)
Controller
attention LED
NVRAM
LED
A B
Bezel
SAS ports (4)
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
Gigabit Ethernet
ports (e0i-e0l)
Power LED
Attention LED
A B
Controller A and B
activity LEDs
A B
Console port
(Setting:
9600 N-8-1)
Remote/Node
Management port
(wrench icon)
ACP port
(locked wrench icon)
Slots for adapter cards Slots for adapter cards
System Setup information: http://support.netapp.com/NOW/public/system_setup/
Data ONTAP 8 library: http://support.netapp.com/documentation/productlibrary/index.html?productID=30092
Licenses: http://support.netapp.com/eservice/agree.do?moduleName=PROTOCOL
Controller and confguration examples; Universal SAS and ACP Cabling Guide: https://library.netapp.com/ecm/ecm_download_fle/ECMM1280392
OnCommand System Manager documentation set: http://support.netapp.com/documentation/productlibrary/index.html?productID=61372
Data ONTAP Express Guides for your version of Data ONTAP: http://support.netapp.com/documentation/productlibrary/index.html?productID=30092
HELPFUL LINKS
Visit the NetApp web site for more information.
Complete System Setup (Choose option A or B below)
4
Complete confguration
5
Create an account and register your system.
Get your license keys.
Register at support.netapp.com 1
Provision more storage.
Confgure other protocols, data protection, and AutoSupport.
Set up Service Processor and Remote Support Agent.
Download OnCommand System Manager
From http://support.netapp.com/NOW/cgi-bin/software/
3
Download and run Confg Advisor
From http://support.netapp.com/NOW/download/tools/confg_advisor/
2
For Clustered Data ONTAP For 7-Mode, HA
5 1 2 3 4
4 1 2 3 5
Enter the values from the confguration
workbook worksheets when prompted by setup script.
Complete initial
network confguration
4
Complete confguration worksheets
From NetApp System Installation Workbook
https://feldportal.netapp.com;
search for "NetApp System Installation Workbook"
1
Power on all disk shelves,
check IDs, and then
power on the controllers.
3
ALL power supplies MUST be powered on.
A
B
1
2
LNK LNK
IOM6
I O M 6
LNK LNK
IOM6
I O M 6
DC AC
x2
2
DC AC
x2
2
Install System Setup software
Do not power on your system until directed
by System Setup software
Both power supplies MUST be powered on.
the system.
Wait for discover to complete.
Enter the values from the confguration worksheet
into System Setup.*
Complete confguration worksheet
From http://support.netapp.com/NOW/
public/system_setup/
1
Install and run System Setup software 4
*If you cannot use System Setup, see the Data ONTAP Software Setup Guide.
Power on all disk shelves ONLY
and check IDs
3
Cable Windows client to same
network as your controllers
2
2 4 6 8
1 3 5 7
10 12 14 16
9 11 13 15
12
11
14
13
16
15
6
5
8
7
10
9
2
1
4
3 1000/100/10M
LNK /
1000/100/10M
LNK /
MANAGEMENT SUBNET
WINDOWS CLIENT
VLAN
FAS8040/8060
SYSTEM
A B
N
e
t
A
p
p

s
u
p
p
o
r
t

s
i
t
e
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK
e0i e0j e0k e0l e0g 0g e0h 0h e0f 0f e0e 0e e0d e0c e0b e0a 0a 0b 0c 0d
1
2
3
4
Cable serial console
2
Prepare for installation (Choose option A or B below)
1
4 5 1 2 3
Installation and Setup Instructions
FAS8040 and FAS8060 Systems
Power cables
Confguration
worksheet
Storage,
starter network,
and 10 GbE cables
Power cables
Storage,
starter network,
and 10 GbE cables
Serial cable
For Clustered Data ONTAP For 7-Mode, HA A B
In the box: In the box:
Download: Download:
Microsoft Windows client
Runs the software to confgure
your storage system
Screwdriver
Additional network cables
For connecting your storage to your network
switch and Microsoft Windows client
Rack space - 6U
You provide:
Additional network cables
For connecting your storage to your network
switch and Microsoft Windows client
Screwdriver
Rack space - 6U
Serial console connection
Connection to DB9 serial console port
or USB-to-DB9 converter to laptop
You provide:
System Setup Software
http://support.netapp.com/NOW/public/system_setup/
OnCommand System Manager
http://support.netapp.com/NOW/cgi-bin/software/
NetApp System Installation workbook
https://feldportal.netapp.com;
search for "NetApp System Installation Workbook"
OnCommand System Manager
http://support.netapp.com/NOW/cgi-bin/software/
210-06179+A0