Sie sind auf Seite 1von 7

Heat recovery units

The air we breathe is important for our life!

One can live 3 weeks without food, 3 days without water, 3 minutes without air!

People in industrialized countries spend indoor, on average about 90% of the year. Modern buildings and systems do not
allow natural ventilation. This is a major precondition for creation of mechanical ventilation.

The fresh air must be heated in winter and chilled in


summer, and this is related with significant energy
costs. There is a preliminary trend for growing of the
price of energy resources for the last 10 years:

Human health and productivity are closely connected with the air quality. Our children
need fresh air even more than us – it could help to avoid illnesses and allergies.

Energy consumption leads to environmental pollution and exhausting of resources of the


planet. It is our duty to protect it for future generation.

Quickly return on investments using heat recovery systems:

The data shown are not universal. These parameters are valid
for the following conditions:
- Bulgaria, Sofia;
- Indoor temperature 22oC;
- Air flow – 3000m3/h;
- Installation working time – 10 of 24h.
- Installation life time – 10 years;
- Energy price – 0.1 Euro/kWh;
- 8% annual maintenance costs;
- Energy price growth – 12% per year;
- The initial expenses are average;


Your lost money!


Heat recovery units

Heat recovery systems are the proper technical and economically acceptable solution:

Q ,kWh
ENERGY CONSUMPTION PER YEAR, kWh
10000
9000
8000
7000
AHU - A System without
6000 recuperation
5000
4000

AHU - A
E=0%
3000
2000
1000
0

-15 -10 -5 0 5 10
text , оС

Q ,kWh
ENERGY CONSUMPTION PER YEAR, kWh
10000
9000
AHU - A
8000
7000 AHU - B
System with plate
6000
5000
heat exchanger
4000

REC 3000
AHU - B
2000 E=45 – 58%
1000
0

-15 -10 -5 0 5 10
text , оС

Q ,kWh ENERGY CONSUMPTION PER YEAR, kWh


10000
9000
8000
AHU - A
System with high-
7000
efficiency plate heat
AHU - C
6000
5000
4000
exchanger
AHU - C REC REC 3000
2000
1000
0
E=65 – 70%
-15 -10 -5 0 5 10
text , оС

Q ,kWh ENERGY CONSUMPTION PER YEAR, kWh


10000
9000
8000 AHU - A

7000
6000
AHU - D System with rotary
5000 heat exchanger
4000
3000
AHU - D
2000
1000
E=70 – 83%
0

-15 -10 -5 0 5 10
text , оС

E - % percentage of recovered energy


Q ,kWh
ENERGY CONSUMPTION PER YEAR, kWh
10000
9000
AHU - A
8000
7000 AHU - E
6000

Applications of heat recovery


5000
4000
units:
AHU - E REC 3000
2000
Ventilation and air-conditioning
1000 systems, which provide fresh air supply in:
- Office and residential buildings;
0

-15 -10 -5 0 5 10
- Hotels, restaurants, cafes, nightclubs; text , оС

- Sports halls, gyms and swimming pools;


- Hospitals, schools, laboratories;
- Cinemas, theaters, concert halls;
- Food industries – bakeries;
- Technological systems;
- Industrial ventilation.


2
Heat recovery units

Standard range – EVB-AL

Е = 45 ÷ 57%

Middle range low pressure - EVB-CBM

Е = 52 ÷ 58%

Middle range, high pressure - EVB-CBP

Е = 52 ÷ 56%

High efficiency range – EVB-TOP/ PLUS

Е = 65 ÷ 70%

Rotary regenerative exchanger range - EVB-ROT

Е = 70 ÷ 83%

Note: For flow rate higher than mentioned, see Section 6 – Air handling units.


3
HEAT RECOVERY UNITS MIDDLE RANGE – HIGH PRESSURE EVB AL-CBP 05.03-01

EVB AL-cbP – HEAT RECOVERY UNITS


MIDDLE RANGE – HIGH PRESSURE

Description
• Cross flow aluminum plate heat exchanger with efficien-
• Units for secondary use of energy of the exhaust air in
cy up to 55%
ventilation and air-conditioning systems.
• Double inlet belt driven centrifugal fans – 380V, 50 Hz
• Operation temperatures from -20°C to +50°C.
• Air filters class G4 – EN 779:2002
• Designed to work with clean air in non-aggressive and
non-sparkling environment. • Rectangular duct connector
• Drain tray with ½” connection
• Service doors – from the side
• By-pass with multiple leaf damper - on request
Construction
• Heating/cooling coil – on request
• Supporting construction, made by anodized aluminum • Support frame or basic steps – on request
profiles
• Roof panels for outdoor installation – on request
• Thermo- and sound insulated panels, powder coated
• Control and management systems - see section 7
RAL7035: Sandwich panels – 25 mm with XPS insulation
class M1 or fiberglass class M0.


23
05.03-02
EVB AL-CBP HEAT RECOVERY UNITS MIDDLE RANGE – HIGH PRESSURE

Overall and joined dimensions

EVB AL-CBP, Standard version – vertical installation

Recuperative
Model Fan B [mm] H [mm] L [mm] b [mm] h [mm] c [mm] d [mm]
exchanger
ЕVB AL-41 CBP CBP 10/10 RECAL-600/5-040 1150 1350 1900 335 290 600 400
ЕVB AL-61 CBP CBP 12/9 RECAL-1200/9-060 850 2000 2500 400 340 500 600
ЕVB AL-81 CBP CBP 15/15 RECAL-1200/9-080 1050 2000 3000 470 400 600 600

EVB AL-CBP, V – Vertical installation

Heating/cooling B H L L1 b h c d
Model Fan
coil [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
ЕVB AL-41 CBP CBP 10/10 800/500 – 2R 1150 1350 1900 1500 335 290 600 400
ЕVB AL-61 CBP CBP 12/9 800/800 – 2R/ 4R 1050 2000 2500 1600 310 340 500 600
ЕVB AL-81 CBP CBP 15/15 1000/800 – 2R/ 4R 1250 2000 3000 1800 470 400 600 600


24
HEAT RECOVERY UNITS MIDDLE RANGE – HIGH PRESSURE EVB AL-CBP 05.03-03

Aerodynamic characteristics

EVB AL-41 CBP

External pressure [Pa]

Air flow [m3/h]

EVB AL-61 CBP


External pressure [Pa]

Air flow [m3/h]

EVB AL-81 CBP


External pressure [Pa]

Air flow [m3/h]


Note: - - - - - - the curve is valid for EVB-CBP with incorporated water heating coil COT 2R

25
05.03-04
EVB AL-CBP HEAT RECOVERY UNITS MIDDLE RANGE – HIGH PRESSURE

Sound pressure level on frequency bands [dB]

Model min-1 Hz 63 125 250 500 1000 2000 4000 8000


Inlet 66 66 69 67 67 60 52 45
1400 min-1 Outlet 66 68 72 71 79 78 69 64
Rad. 64 59 60 54 54 48 37 30
Inlet 67 67 70 68 68 61 53 46
1500 min-1 Outlet 67 69 73 72 80 79 70 65
Rad. 65 60 61 55 55 49 40 32
EVB AL-41 CBP
Inlet 68 68 71 69 69 62 54 47
1600 min-1 Outlet 68 70 74 73 81 80 71 66
Rad. 66 61 62 56 56 50 42 34
Inlet 69 69 72 70 70 63 55 49
1700 min-1 Outlet 69 71 75 74 82 81 72 67
Rad. 67 62 63 57 57 51 44 36
Inlet 68 68 70 69 69 62 54 47
1000 min-1 Outlet 68 70 73 74 81 80 71 64
Rad. 66 61 62 56 56 50 42 34
Inlet 70 70 72 71 71 64 56 49
EVB AL-61 CBP 1200 min-1 Outlet 70 72 75 76 83 82 73 66
Rad. 68 63 64 58 58 52 44 36
Inlet 72 72 74 73 75 69 58 51
1400 min-1 Outlet 72 74 77 78 85 87 75 68
Rad. 70 65 66 60 58 57 46 38
Inlet 69 67 69 68 67 61 54 42
800 min-1 Outlet 69 69 72 72 77 77 67 60
Rad. 67 60 61 55 52 46 40 30
Inlet 70 68 70 69 68 62 55 43
EVB AL-81 CBP 1000 min-1 Outlet 70 70 73 73 78 78 68 61
Rad. 68 61 62 56 53 47 42 32
Inlet 75 73 75 74 73 68 60 48
1200 min-1 Outlet 75 75 78 78 83 83 73 66
Rad. 72 65 63 61 58 55 47 39

Note: Measured in free field conditions at a distance 1,5 m.

Order designation

EVB AL - 41/1600 CBP


Model/Speed
Heat recovery unit


26

Das könnte Ihnen auch gefallen