Loading applied at top of cap DESIGN CALCULATION Pile Cap P1 PILE ARRANGEMENT Given Values Pile spacing : P s = 1.500 m Edge distance (from pile center to free edge of cap) : e = 0.500 m. Column size (in investigated direction): h = 0.450 m Column size (in investigated perpendicular direction) : b = 0.250 m Pile Diameter : d p = 0.500 m Pile Capacity : P p = 500.000 kN Load Case F x (kN) F y (kN) F z (kN) M x (kNm) M y (kNm) M z (kNm) 11 -2.598 -193.769 0.486 1.134 0.000 2.504 12 1.059 -185.373 0.763 1.479 0.000 -3.305 13 -4.946 -205.375 -0.026 0.526 0.000 7.120 14 -5.923 -61.185 22.741 26.355 0.000 5.346 15 -1.881 -257.990 -9.561 -10.360 0.000 2.151 16 1.483 -151.657 1.024 1.778 0.000 -6.013 17 -6.421 -203.954 -0.374 0.055 0.000 10.358 18 -3.055 -93.740 8.433 10.496 0.000 2.218 19 -2.011 -277.834 -7.622 -8.445 0.000 2.458 20 1.317 -153.446 0.443 1.045 0.000 -3.969 21 -4.688 -173.448 -0.347 0.092 0.000 6.456 22 -5.665 -29.258 22.421 25.921 0.000 4.683 23 -1.623 -226.063 -9.882 -10.794 0.000 1.487 Concrete : f' c = 25000.004 kN/m^2 Reinforcement : f y = 415000.070 kN/m^2 The cap design is based on actual pile reactions Pile Cap size (in investigated direction) H = 2.299 m Pile Cap size (in investigated perpendicular direction) B = 2.500 m Page 1of 5 Pile Cap Design 17-07-2014 file:///C:/Staad.foundation%205/CalcXsl/PileCapde.xml Results Summary Dimensions of Pile Cap Governing LoadCase Thickness of Pile Cap CHECK FOR PILE CAP THICKNESS Check for Moment (Along Base Beam) Length of Pile Cap (PC L ) = 2.299 m Width of Pile Cap (PC W ) = 2.500 m LoadCase Number :- 19 Moment and Shear check = 1.127 m Critical Load Case : 19 Total pile number N = 3 Arrangement Reaction Pile No. X (m) Y (m) Axial (kN) Lateral (kN) Uplift (kN) 1 -0.750 0.433 -90.997 2.628 0.000 2 0.000 -0.866 -99.118 2.628 0.000 3 0.750 0.433 -87.719 2.628 0.000 Pile Cap size (in investigated direction) H = 2.299 m Pile Cap size (in investigated perpendicular direction) B = 2.500 m Calculated Thickness (t) = 1.127 m Length of Column (C L ) = 0.450 m Width of Column (C W ) = 0.250 m Strength of Concrete (F C ) = 25000.004 kN/m^2 Bottom Cover (C LB ) = 0.050 m Pile in Pile Cap (P CP ) = 0.075 m Effective Depth (d) = 0.977 m Hence Governing moment (M u ) =-65.788 kNm We assume singly reinforced and under reinforcement section Effective Depth(d ef ) = =0.977 m Page 2of 5 Pile Cap Design 17-07-2014 file:///C:/Staad.foundation%205/CalcXsl/PileCapde.xml Check for Moment (Along Alternate Beam) Check for One-Way Shear (Along Base Beam) Check for One-Way Shear (Along Alternate Beam) Depth of nutral axis for balanced section(x u ) =0.468 m As Per IS 456 2000 ANNEX G,G-1.1 C Ultimate moment of resistance(M ulim ) = =4867.459 kNm We observed M u <=M ulim hence singly reinforced and under reinforced section can be used Hence Governing moment (M u ) =-85.839 kNm We assume singly reinforced and under reinforcement section Effective Depth(d ef ) = =0.977 m Depth of nutral axis for balanced section(x u ) =0.468 m As Per IS 456 2000 ANNEX G,G-1.1 C Ultimate moment of resistance(M ulim ) = =4867.459 kNm We observed M u <=M ulim hence singly reinforced and under reinforced section can be used Design Shear force (V u ) =-87.719 kN As Per IS 456 2000 ANNEX B,B-5.1 Design Shear Stress (T v ) = =60.788 kN/m^2 Allowable Shear Stress (T c ) = =120.222 kN/m^2 Where Beta = =128.316 and percentage of steel required (p t ) = =0.376 Here T v <=T c Hence safe Design Shear force (V u ) =-170.595 kN As Per IS 456 2000 ANNEX B,B-5.1 Design Shear Stress (T v ) = =118.220 kN/m^2 Page 3of 5 Pile Cap Design 17-07-2014 file:///C:/Staad.foundation%205/CalcXsl/PileCapde.xml Calculation of Maximum Bar Size Selection of Reinforcement Along Base Beam Along Alternate Beam Allowable Shear Stress (T c ) = =120.222 kN/m^2 Where Beta = =128.316 and percentage of steel required (p t ) = =0.376 Here T v <=T c Hence safe Selected maximum bar size =#12 Bar diameter corresponding to max bar size (d b ) = 12 mm Development Length (l d ) = =3223.654 mm Allowable Length (l db ) (for Base beam)= =1500.000 mm Allowable Length (l db ) (for Alternate beam)= =1299.075 mm l db >l d hence, safe As Per IS 456 2000 Clause 26.5.2.1 Minimum Area of Steel (A stmin ) = =1834.434 mm2 As Per IS 456 2000 ANNEX G,G-1.1 b Area of steel required (A sq ) = =1830.889 mm2 Area of steel provided (A st ) = =1834.434 mm2 A stmin <=A st Steel area is accepted Minimum spacing allowed (S min ) =40 +d b =52 mm Selected spacing (S) =27.37 mm S min <=S <=450 mm and selected bar size <selected maximum bar size... The reinforcement is accepted. As Per IS 456 2000 Clause 26.5.2.1 Minimum Area of Steel (A stmin ) =1834.434 mm2 As Per IS 456 2000 ANNEX G,G-1.1 b Page 4of 5 Pile Cap Design 17-07-2014 file:///C:/Staad.foundation%205/CalcXsl/PileCapde.xml Area of steel requared (A sq )= =1864.565 mm2 Area of steel provided (A st ) = =1864.565 mm2 A stmin <=A st Steel area is accepted Minimum spacing allowed (S min ) =40 +d b =90.00 mm Selected spacing (S) =450.00 mm S min <=S <=450 mm and selected bar size <selected maximum bar size... The reinforcement is accepted. Print Calculation Sheet Page 5of 5 Pile Cap Design 17-07-2014 file:///C:/Staad.foundation%205/CalcXsl/PileCapde.xml