Sie sind auf Seite 1von 18

EDEXCEL HNC/D

PLANT and PROCESS PRINCIPLES



OUTCOME 2

TUTORIAL 2 - STEADY FLOW ENERGY EQUATION


2 Steady flow energy equation (SFEE)

SFEE: consideration and applications of continuity of mass; first law of thermodynamics;
principle of conservation of energy; work flow; heat transfer; kinetic energy; potential
energy; pressureflow energy; internal energy; enthalpy

Application of SFEE to plant: assumptions made in specific applications; energy transfer
and efficiency calculations for specific items of plant (eg economisers, boilers, superheaters,
turbines, pumps, condensers, throttles, compressors); boiler efficiency



It is assumed that the student is already familiar with the use of tables to find the properties
of fluids and the use of gas laws. If you are not you will find tutorials on this in the Edexcel
module Thermodynamics and in the general area of Thermodynamics
(www.freestudy.co.uk)


In this tutorial we examine specific plant items as listed above. You will also find good
quality learning material at
http://www.spiraxsarco.com/learn/

And free tables for finding the properties of steam and water at
http://www.spiraxsarco.com/esc/
D.J.Dunn freestudy.co.uk 1

STEADY FLOW PLANT

Steam power plant contains most of the items to be examined but many of them are found
elsewhere. The graphic below indicates the basic plant used in simple steam power plant.
The thermodynamic cycle is based on the Rankine Cycle and you can find tutorials on this in
the thermodynamic module.

Most of the plant items are heat exchangers of one kind or other.

The boiler is a series of heat exchangers that evaporates the feed water and then superheats
it. The source of heat may be from the combustion of fossil fuel or hot gas from a nuclear
reactor.

The steam passes to a turbine where it gives up its energy (enthalpy) to mechanical power
that drives the alternator and produces electric power.

The steam leaving the turbine is condensed in the condenser. This is another heat exchanger
that uses cooling water.

The cooling water is circulated to a cooling tower (or another source of cooling such as the
sea, river or lake).

The condensate is pumped back to the boiler but it is heated in another heat exchanger called
an economiser. This uses the hot gas (usually flue gas) exiting the boiler.



In a full blown power station, there will be several feed heaters, a reheater and an air pre-
heater. There will also be feed water heaters, de-aerators, de-superheaters, hot wells and
many other things. The purpose of this module is to examine the energy transfers occurring
and the efficiencies of the plant items.
D.J.Dunn www.freestudy.co.uk 2
BOILER

There are many types of boilers ranging from small hot water boilers to large power station
boilers producing superheated steam.

A main power station boiler will have an economiser, an evaporator, a superheater, a
reheater and an air preheater (recuperator) all of which improve the efficiency. The diagram
shows the arrangement for a medium size boiler using water walls. The walls of the furnace
are entirely surrounded by vertical pipes banked so close together that they form a curtain
wall. Water from the drum passes down the down comer pipe and is distributed to the water
wall with a circulating pump. The steam from the top returns to the steam space inside the
drum. Steam is drawn off from the same space and superheated in a bank of heat exchanger
tubes. The superheater is placed in the hottest part of the flue. The economiser is in the
coolest part of the flue.

MEDIUM SIZE POWER STATION BOILER

Some boilers (once through types) are designed as one long heat exchanger with water
entering one end and superheated steam leaving the other and there is no clearly defined
evaporator section.

Industrial process steam is usually dry or wet so many boilers do not have a superheater.

It is not practical to cover the many types of boilers on the market. The pictures show typical
package boilers delivered fully constructed to the site.



TYPICAL PACKAGE BOILERS
D.J.Dunn www.freestudy.co.uk 3
APPLYING THE STEADY FLOW ENERGY EQUATION

All the units described are basically heat exchangers. The main point is that a heat transfer
rate is needed into the boiler unit in order to heat up the water, evaporate it and superheat it.

The heat transfer to the water or steam is found by applying the Steady Flow Energy
Equation. + P = (PE)/s + (KE)/s + (H)/s

In the case of any heat exchanger, P = 0 as there is no work done. The velocity of fluids
should be low otherwise there will be pressure losses and there should not be much
difference between the inlet and outlet so kinetic energy is usually neglected. The inlet and
outlets of the heat exchanger may be at different levels so potential energy changes might
exist but this is likely to be small compared to the other energy terms so this is normally
neglected as well. In this case the SFEE becomes:

= H/s = m (h)

h is the change in specific enthalpy of the fluid. is the heat transferred into or out of the
fluid and m is the mass flow rate. This may be applied to the boiler in its entirety or to any of
the units within the boiler.

For steam we need to use steam tables to find the enthalpy values. You should already know
that:
h
f
is the specific enthalpy of saturated water.
h
fg
is the specific enthalpy of evaporation.
h
g
is the specific enthalpy of dry saturated steam h
g
= h
f
+ h
fg
For superheated steam h values
For wet steam with dryness fraction x h = h
f
+ xh
fg

For low pressure water h = c
w
where c
w
is the specific heat (about 4.2 kJ/kg K) and the
temperature in
o
C. Celsius is used because specific enthalpy is arbitrarily taken as zero at
0
o
C. For high temperatures and pressure the specific heat changes significantly and it is best
to use the table below.

The enthalpy of steam and water may be found at http://www.spiraxsarco.com/esc/

For gases, the enthalpy change may be found with specific heats so that h = c
p
where c
p

is the specific heat at constant pressure and these can be found from tables. Note that these
values also vary with temperature and so care should be taken.

TABLE FOR THE ENTHALPY OF HIGH PRESSURE WATER

Pressure in bar Temp
o
C
0 25 50 75 100 125 150 175 200 221 250
0 0 2.5 5 7.5 10 12.6 15 17.5 20 22 25
20 84 86 87 91 93 96 98 100 103 105 107
40 168 170 172 174 176 179 181 183 185 187 190
60 251 253 255 257 259 262 264 266 268 270 272
80 335 337 339 341 343 345 347 349 351 352 355
100 419 421 423 425 427 428 430 432 434 436 439
120 504 505 507 509 511 512 514 516 518 519 521
140 589 591 592 594 595 597 599 600 602 603 605
160 675 677 678 680 681 683 684 686 687 688 690
180 763 764 765 767 767 769 790 772 773 774 776
200 852 853 854 855 856 857 858 859 861 862 863

D.J.Dunn www.freestudy.co.uk 4
OVERALL BOILER EFFICIENCY

The heat input to a boiler comes from various sources. Fossil fuels are one of the most
common sources and the heat input is given by:
= mass/s x calorific value - solid fuels
=volume/s x calorific value - gas fuels
Typical calorific values are: Coal 30 36 MJ/kg
Fuel Oils 43 46 MJ/kg
Natural Gas 38 MJ/m
3
Other sources of heat are hot gasses such as the CO
2
used on nuclear power stations and hot
flue gas used with waste heat boilers.


WORKED EXAMPLE No.1

A hot water boiler produces 0.24 kg/s of hot water at 80
o
C from cold water at 18
o
C.The
boiler burns fuel oil at a rate of 1.6 g/s with a calorific value of 44 MJ/kg. Calculate the
thermal efficiency of the boiler.

SOLUTION

The easiest way to find the increase in enthalpy of the water is to use the specific heat
assumed to be 4.186 kJ/kg K.

= m c = 0.24 x 4.186 x (80 18) = 62.29 kW
Heat released by combustion = m
f
x C.V.
Heat released by combustion = 1.6 x 10
-3
(kg/s) x 44 000 (kJ/kg) = 70.4 kW

th
= (62.29/70.4) x 100 = 88.5%



WORKED EXAMPLE No. 2

A steam boiler produces 0.2 kg/s at 50 bar and 400
o
C from water at 50 bar and 100
o
C.
The boiler burns 5.3 m
3
/min of natural gas with a calorific value of 38 MJ/ m
3
. Calculate
the thermal efficiency of the boiler.

SOLUTION

The enthalpy of the steam produced is found in tables at 50 bar and 400
o
C.
h
2
= 3196 kJ/kg
The enthalpy of the water is found from the table at 50 bar and 100
o
C.
h
1
= 5 423 kJ/kg

Energy given to the water and steam = m (h
2
- h
1
) = 0.2 (3196 - 423) = 3111 kW
Energy from burning the fuel = Vol/s x C.V.
Energy from burning the fuel = (5.3/60)(m
3
/s) x 38 000 (kJ/m
3
) = 3357 kW

th
= (3111/3357) x 100 = 92.7%


D.J.Dunn www.freestudy.co.uk 5

SELF ASSESSMENT EXERCISE No. 1

1. A hot water boiler produces 0. 4 kg/s of hot water at 70
o
C from cold water at 10
o
C. The
boiler burns fuel oil at a rate of 3.2 g/s with a calorific value of 44 MJ/kg. The specific
heat of water is 4.186 kJ/kg K.
Calculate the thermal efficiency of the boiler. (71.4 %)

2. A steam boiler produces 3 kg/s at 70 bar and 500
o
C from water at 70 bar and 120
o
C. The
boiler burns 17 m
3
/min of natural gas with a calorific value of 38 MJ/ m
3
. Calculate the
thermal efficiency of the boiler. (80.8%)


ECONOMISER

6
The economiser is a heat exchanger that
passes heat from the flue gas to the feed
water. The feed water temperature is
hence hotter than it would otherwise be
and less heat is required to produce
steam from it. Alternatively more steam
can be raised for the same amount of
heat. An increase in temperature of 10C
can improve the boiler efficiency by as
much as 2%.


SHELL BOILER WITH ECONOMISER

Because the economiser is on the high-pressure side of the feed pump, feed water
temperatures in excess of 100C are possible. Note that the flue gas should not be cooled to
the dew point to prevent acidic water forming. The diagram shows the layout for a small
shell boiler.

The efficiency of an economiser refers only to how well it transfers heat and this is only
affected by the heat transfer through the walls of the tubes. They are prone to sooty deposits
forming on the flue gas side and this reduces the heat transfer rate. They are designed to be
cleaned easily. A finned heat exchanger tube such as shown should have the fins arranged
vertically so that soot will fall off them. Plain tubes have scrapers fitted for cleaning them
mechanically. Steam blowing is a technique used to blast the soot off the fins with a steam
jet but this can cause atmospheric pollution.



D.J.Dunn www.freestudy.co.uk


WORKED EXAMPLE No. 3

A boiler is supplied with 6 MW of heat and produces 0.5 kg/s of steam at 100 bar from
feed water at 40
o
C with an efficiency of 65%. If an economiser is fitted that raises the
feed water temperature to 180
o
C, what would be the new boiler efficiency? Assume that
the heat input to the boiler is reduced by the amount saved by fitting the economiser.
The table for the enthalpy of water should be used.

SOLUTION

The heat given to the steam is 65% x 6 MW = 3.9 MW

The enthalpy of water at 100 bar and 180
o
C is 767 kJ/kg

The enthalpy of water at 100 bar and 40
o
C is 176 kJ/kg

The heat given to the water = m
w
h = 0.5(767 176) = 295.5 kW

The heat transfer is reduced to 6 0.2955 = 5.7045 MW

The efficiency is 3.9/5.7045 = 0.684 or 68.4%




WORKED EXAMPLE No. 4

Measurements for the boiler and economiser described in example 1 show that the flue
gas is cooled from 250
o
C to 150
o
C over the economiser. The specific heat of the flue gas
is 1.1 kJ/kg K. Assuming 100% heat exchange, determine mass flow of the flue gas.

SOLUTION

The heat given to the water is 295.5 kW
The heat lost from the flue gas is m
g
h = m
g
c
p
T = m
g
1.1 x (250 150) = 295.5 kW
If the transfer is 100% then we can equate.
m
g
= 295.5/110 = 2.686 kg/s

D.J.Dunn www.freestudy.co.uk 7
EVAPORATOR

All steam boilers evaporate the feed water. The feed water should be as close to the boiling
point as possible to reduce the heat needed to evaporate it. The steam produced should
ideally be dry steam but in practice a small amount of water is carried over with it so the
steam is typically 98% dry (dryness fraction 0.98). It is not possible to produce superheated
steam without a superheater section.

In large power station boilers the evaporator is a water wall surrounding the furnace as
described earlier. These are also called water tube boilers because the tubes contain the water
with hot gas on the outside. The boiler with water walls and heater tube banks as shown
earlier fits this category.

In smaller boilers the water may be contained inside a shell and heated by hot gas passing
through the tubes. These are shell boilers and also called fire tube boilers because the hot gas
passes through the tubes.

SHELL BOILER WITH FIRE TUBES



WORKED EXAMPLE No. 5

The evaporator section of a boiler uses 20 kg/s of feed water at 50 bar and 200
o
C. The
steam produced is 98% dry. Calculate the heat transfer.

SOLUTION

Heat transfer = mass x h

Specific enthalpy of feed water is h
1
= 854 kJ/kg (from the table)
The specific enthalpy of the steam is h
2
= h
f
+ 0.98 (h
g
)
These values must be found from steam tables and we find that at 50 bar:

h
f
= 1155 kJ/kg and h
g
= 1639 kJ/kg
h
2
= 1155 + 0.98 (1639) = 2761.2 kJ/kg


in
= m(h
2
- h
1
) = 20(2761.2- 1639) = 22444 kW or 22.444 MW


D.J.Dunn www.freestudy.co.uk 8
SUPERHEATER

This is a heater placed in the hottest part of the boiler that raises the temperature of the steam
well beyond the saturation temperature.




WORKED EXAMPLE No. 6

A superheater produces 34 kg/s of steam at 70 bar and 400
o
C from steam 97% dry.
Calculate the heat transfer to the steam.

SOLUTION

From the steam tables (superheat section) the enthalpy of the superheated steam is
h
2
= 3158 kJ/k K at 70 b and 400
o
C
From the saturated steam section h
f
= 1267 and h
fg
= 1505 kJ/kg K at 70 bar.

h
1
= 1267 + 0.97(1505) = 2726.85 kJ/kg K

= mh = 34(3158 - 2726.85) = 14659 kW or 14.659 MW




WORKED EXAMPLE No. 7

The same superheater given in the last example cools the flue gas by 700 K. The mean
specific heat is 1.15 kJ/kg K. The air fuel ratio for the furnace is 14/1.

Determine the mass flow of the flue gas and the mass of fuel being burned.

SOLUTION

Assuming the heat lost by the gas all goes into the steam we can equate.

= m
g
c
p
= m
g
1.1(700) = 770 m
g
kW
= 14659 = 770 m
g
m
g
= 19.03 kg/s

The mass of gas = mass of fuel + mass of air
19.03 = m
f
+ m
a
19.03 = m
f
+ 14 m
f
= 15 m
f

m
f
= 19.03/15 = 1.269 kg/s

D.J.Dunn www.freestudy.co.uk 9
TURBINE

The turbine converts the enthalpy in the steam into mechanical power. Applying the steady
flow energy equation gives:
+ P = (PE)/s + (KE)/s + (H)/s

In an ideal turbine, the heat loss from the case is reduced to near zero by lagging. The change
in potential and kinetic energy are usually negligible so this reduces to :
P = H = m(h)
P is the power given up by the steam and h the change in specific enthalpy of the steam.
Turbines in real plant are often in several stages and the last stage is specially designed to
cope with water droplets in the steam that becomes wet as it gives up its energy. You must
use the isentropic expansion theory in order to calculate the dryness fraction and enthalpy of
the exhaust steam.

The picture shows a large steam turbine stripped for service. There are three sections, high,
intermediate and low pressure. The steam enters at the middle of each and flows away in
both directions to reduce axial forces on the rotor.



WORKED EXAMPLE No. 8

A steam turbine is supplied at 100 bar and 400
o
C. The steam exits the turbine at 0.07 bar
and dryness fraction 0.73. The flow rate of steam is 55 kg/s. Calculate the power output
from the turbine assuming 100% energy transfer from the steam.

SOLUTION

The specific enthalpy of the steam supplied is found from tables for superheated steam.
h = 3097 kJ/kg (100 bar and 400
o
C).
The specific enthalpy of wet steam is h = h
f
+ x
3
h
fg
= 163 + 0.733(2409) = 1928 kJ/kg
(The values are found in tables for saturated steam).
The power out of the turbine is P = m
s
h = 55(3097 - 1928) = 64.3 MW

D.J.Dunn www.freestudy.co.uk 10

CONDENSER

The condenser removes energy from the steam and converts it back to water. Applying the
Steady Flow Energy Equation gives:
+ P = (PE)/s + (KE)/s + (H)/s

There is no work (power) extracted from a condenser. Kinetic and potential energy terms are
negligible so the equation reduces to = H = m (h)

is the heat transfer rate from the steam and water. h is the change in enthalpy of the
steam and water.


WORKED EXAMPLE No. 9

A steam condenser receives 55 kg/s of wet steam at 0.07 bar and 0.73 dryness fraction.
The steam is completely condensed to saturated water. Assuming 100% heat transfer,
determine the heat transfer to the cooling water.

If the cooling water temperature must not rise by more than 20K, what should the flow
rate be? Assume the specific heat of water is 4.2 kJ/kg K.

SOLUTION

The specific enthalpy of the steam entering the condenser is:

h = h
f
+ x h
fg
= 163 + 0.73(2409) = 1928 kJ/kg (from tables at 0.07 bar)

The specific enthalpy of the condensate is simply h
f
at 0.07 bar = 163 kJ/kg

The heat transfer from the steam is = m
s
(h) = 55(1928 - 163) = 97.1 MW

If all this is transferred to the cooling water then the we can equate :

m
w
c
w
T = m
w
4.2 (20) = 97100 kW
kg/s 1156
(4.2)(20)
97100
m
w
= =




SELF ASSESSMENT EXERCISE No. 2

A steam condenser takes in wet steam at 8 kg/s and dryness fraction 0.82. This is
condensed into saturated water at outlet. The working pressure is 0.05 bar.
Calculate the heat transfer rate. ( = 15896 kW)


D.J.Dunn www.freestudy.co.uk 11
PUMPS

Pumps come in many types and sizes. A large boiler will have circulation pumps, feed water
pumps, condensate pumps and cooling water circulation pumps.


The energy given to the water by the pump is also found from the Steady Flow Energy
Equation as
+ P = (PE)/s + (KE)/s + (H)/s

The ideal pump has no heat loss and again the change in potential and kinetic energies are
usually negligible so this reduces to:
P = H = m (h)

Remember that h = u + (pV). If the water is incompressible, the temperature is not
raised and the volume does not change so u = 0 and (pV) = Vp. The work (power)
transferred from the fluid is then:
P = V p

The actual power input to the pump is greater because of mechanical losses and friction in
the impeller. There may also be some heat loss from the casing but this is very small in
comparison to the power on large feed pumps. If losses of all kinds are taken into account we
define the overall efficiency of the pump as
Power Actual
Power Ideal
=



WORKED EXAMPLE No. 10

A circulation pump delivers 40 kg/s with a pressure rise of 2 bar. The overall efficiency
is 82%. Calculate the power input required.

SOLUTION

Neglecting Kinetic and Potential Energy P = V p
The volume = mass/density The density of water is nominally 1000 kg/m
3
V = 40/1000 = 0.04 m
3
/s
P = 0.04 x 2 x 10
5
= 8000 W



D.J.Dunn www.freestudy.co.uk 12


WORKED EXAMPLE No. 11

A feed pump delivers 55 kg/s of water. The inlet pressure is 1.0 bar and the delivery
pressure is 100 bar. The inlet temperature is 40
o
C. The efficiency of the pump is 85%
and is entirely due to mechanical effects. Heat loss, kinetic and potential energy may be
taken as negligible. Assume that the specific volume of water is 0.001 kg/m
3
and
specific heat is 4.2 kJ/kg K.

Calculate the power input.
Calculate the specific enthalpy of the water leaving the pump.
Estimate the temperature at exit.

SOLUTION

To solve this apparently simple problem, we would need very accurate tables and more
advanced theory (involving a property called entropy) to work out the temperature rise
over the pump and this would turn out to be quite small. With the information available,
we can only assume that the the ideal power is P = V p
V = 55 x 0.001 = 0.055 kg/s
P = 0.055(100 - 1) x 10
5
= 544.5 x 10
3
W = 544.5 kW
Actual Power input = 544.5/85% = 544.5/0.85 = 640.588 kW

The specific enthalpy of the water at inlet to the pump is approximately the product of
specific heat x temperature in
o
c giving h = c = 4.2 x 40 = 168 kJ/kg. The table
previous gives 168 kJ/kg so we will take this rounded figure.

Applying the SFEE to the pump and ignoring KE and PE we have:
+ P = H/s = mh and = 0 so P = mh
640.588= 55 h Hence h = 11.7 kJ/kg
The specific enthalpy at outlet is 168 + 11.7 = 179.7 kJ/k

The exit temperature could be obtained from accurate tables. A rough estimate is:
= h/specific heat = 179.7/4.2 = 42.8
o
C

D.J.Dunn www.freestudy.co.uk 13
COMPRESSORS INSTALLATIONS

The purpose of a compressor is to produce a flow of gas and overcome the pressure on the
delivery side. An industrial compressor may be fitted with cooling systems. There are many
types for many functions. The capacity of the air compressor is usually rated as the volume
flow rate at atmospheric conditions and this is called the Free Air Delivery. In other words it
is the volume based on 1.013 bar and 20
o
C which has a density of 1.205 kg/m
3
.

SCREW TYPE VANE TYPE


CENTRIFUGAL AXIAL VANE

One of the most versatile compressors is the reciprocating type. A typical case is shown
below.

Applying the SFEE we have:
+ P = (PE)/s + (KE)/s + (H)/s

We can normally neglect Potential Energy and Kinetic Energy so this reduces to:
+ P = (H)/s = m c
p
()

The Heat loss may be calculated when the compressor is water cooled, otherwise this is
difficult. The specific heat is usually taken as the value at the average temperature. For air
this is normally around 1.005 kJ/kg K.
D.J.Dunn www.freestudy.co.uk 14

WORKED EXAMPLE No. 12

A water-cooled reciprocating air compressor delivers 3.41 m
3
/min FAD. The cooling
water flows at 0.021 kg/s and its temperature is raised by 20 K. The air temperature is
raised by 80 K.
The specific heat of the water and air are respectively 4.2 kJ/kg K and 1.005 kJ/kg K.
Calculate the theoretical power input.
The actual power input is 7.1 kW. What is the overall efficiency of the compressor?

SOLUTION

= m
w
c
w
= 0.021 x 4.2 x 20 = 1.764 kW this is a heat loss so it is negative.
The change in enthalpy for the air is H = m
a
c
p

The mass flow rate of air = volume/density = 3.41/1.205 = 2.83 kg/min or 0.0471 kg/s
H = m
a
c
p
= (0.0471)(1.005)(80) = 3.79 kW
Apply the SFEE + P = (H)/s = m c
p
()
-1.764 + P = 3.79 kW
P = 5.55 kW This is the theoretical power input.
Efficiency = 5.55/7.1 = 0.78 or 78%



SELF ASSESSMENT EXERCISE No. 3

1. A steady flow air compressor draws in air at 20
o
C and compresses it to 120
o
C at outlet.
The mass flow rate is 0.7 kg/s. At the same time, 5 kW of heat is transferred into the
system. Take c
p
as 1005 J/kg K. Calculate the following.
i. The change in enthalpy per second. (70.35 kW)
ii. The work transfer rate. (65.35 kW)

2. A steady flow boiler is supplied with water at 15 kg/s, 100 bar pressure and 200
o
C. The
water is heated and turned into steam. This leaves at 15 kg/s, 100 bar and 500
o
C. Using
your steam tables, find the following.
i. The specific enthalpy of the water entering. (856 kJ/kg)
ii. The specific enthalpy of the steam leaving. (3373 kJ/kg)
iii. The heat transfer rate. (37.75 kW)

3. A pump delivers 50 dm
3
/min of water from an inlet pressure of 100 kPa to an outlet
pressure of 3 MPa. There is no measurable rise in temperature. Ignoring K.E. and P.E,
calculate the work transfer rate. (2.417 kW)

4. A water pump delivers 130 dm
3
/minute (0.13 m
3
/min) drawing it in at 100 kPa and
delivering it at 500 kPa. Assuming that only flow energy changes occur, calculate the
power supplied to the pump. (0.86 kW)

5. A steam condenser is supplied with 2 kg/s of steam at 0.07 bar and dryness fraction 0.9.
The steam is condensed into saturated water at outlet. Determine the following.
i. The specific enthalpies at inlet and outlet. (2331 and 163 kJ/kg)
ii. The heat transfer rate. 4336 kW)

D.J.Dunn www.freestudy.co.uk 15
REFRIGERATION PLANT

Refrigeration plant contains many of the same features as steam plant but the fluids used are
different. A basic circuit is shown below containing a compressor, a cooler/condenser and a
heater/evaporator. The other feature shown is a throttle valve and this needs to be studied
next.

BASIC REFRIGERATION PLANT STRIPPED TO BARE PIPEWORK.

THROTTLE VALVE
16

A throttle is simply a restriction used to drop the pressure of the fluid
with high pressure at inlet and low pressure at outlet. The diagram
shows a variable type. A fixed type might be as simple as a narrow
coiled tube as seen in domestic refrigerators. The affect of dropping
the pressure depends on the type and condition of the fluid. In
refrigerators this is usually a liquid near to the saturation temperature
so that a drop in pressure causes the liquid to boil and instantly
evaporate into a wet vapour with an accompanying drop in temperature. Applying the SFEE
we have:

+ P = (PE)/s + (KE)/s + (H)/s

In this case there is no work (power) and no heat transfer. The change in potential energy is
zero negligible. The kinetic energy could be a factor depending on the pipe sizes, especially
if the fluid expands into a gas with a large volume but velocities should be kept small to
avoid losses. If this is the case then we have the simple result:
(H)/s = 0 and h/s = 0

This means that the enthalpy and hence specific enthalpy has the same value at inlet and
outlet. Remember that enthalpy is the sum of two other energies, internal energy (U) and
flow energy (pV) so:
U
1
+ p
1
V
1
= U
2
+ p
2
V
2
THROTTLING A LIQUID

If the liquid does not evaporate the volume V is near constant so U
1
- U
2
= V p
The internal energy of a liquid is m c where c is the specific heat and the temperature.
m c (
1

2
) = V p
( )
c
p
c m
p V

2 1
= =
This assumes the density is the same at inlet and outlet. This allows us to calculate the
change in temperature. There would have to be a very large change in pressure to produce a
significant temperature change (Typically 40 bar for 1 degree change).
D.J.Dunn www.freestudy.co.uk
THROTTLING A PERFECT GAS

If the fluid is a gas, then h
2
h
1
= mc
p
= 0

It follows that = 0 and there is no change in temperature. There will be a change in
volume

THROTTLING A SATURATED LIQUID

If a saturated liquid undergoes a drop in pressure, the saturation temperature (boiling point)
is also dropped so it cannot exist as a liquid at the lower pressure. Some of the liquid must
change to vapour and in the process absorbs latent heat. This causes the temperature to drop.

Remember h
1
= h
2
so if we have access to tables, we can calculate the dryness fraction and
determine the temperature.

Hot liquids are often vented into a low pressure tank in order to cause rapid cooling and
evaporation.


WORKED EXAMPLE No. 13

A boiler contains high pressure hot water at 50 bar and 200
o
C. A valve is opened on the
bottom of the connecting it to atmosphere at 1.013 bar. Determine the condition of the
substance being vented.

SOLUTION

On the entry side of the valve the water has a specific enthalpy of 854 kJ/kg (from the
water table).

h
1
= 854 kJ/kg

On the atmospheric side of the valve the specific enthalpy is h
f
+ x h
fg
at 1.103 bar.
These values may be found in steam tables giving h
2
= 419.1 + x(2256.7)

Equate 854 = 419.1 + x(2256.7) hence x = 0.193

In other words about 81% of the mass is evaporated in the process. The temperature of
the wet steam emerging from the valve is 100
o
C (the saturation temperature at the lower
pressure).


D.J.Dunn www.freestudy.co.uk 17
GAS TURBINES

A basic gas turbine is illustrated below. Air is compressed and blown into a combustion
chamber where it is heated. The hot air expands through the turbines which drive the
compressor and produces power output. The hot gas exhausts to atmosphere.


WORKED EXAMPLE No. 14

A gas turbine draws in 11.84 kg/s of air at 1 bar and 10
o
C. It exhausts at 1 bar and
400
o
C. The power produced is 2 MW. Neglect the mass of the fuel and assume no heat
losses. Neglect Potential and Kinetic Energy. Take the specific heat of the air as
1.01kJ/kg K.
Determine the heat supplied by the fuel and the thermal efficiency of the unit.

SOLUTION

Taking the unit as a whole we can apply the SFEE.
+ P = (PE)/s + (KE)/s + (H)/s
is the heat input from the fuel if no other source or losses exist.
P = Net Power output
H = enthalpy change of the air.
Neglecting PE and KE we have:
+ P = (H)/s
Note that P = -2000 kW because the power is removed from the system.
In KW units - 2 000 = mc
p
= (11.84)(1.01)(400 10) = 4663.8
Heat Input = 6663.8 kW
Efficiency = P/ = 2000/6663.8 = 0.3 or 30%


SELF ASSESSMENT EXERCISE No. 4

1. Boiling water at 10 bar is throttled to 1 bar. What is the temperature and dryness fraction
after throttling? (99.6
o
C and 0.153)

2. A gas turbine set draws in air at 20
o
C and exhausts at 500
o
C. The fuel supplies 48 MW
of heat. The power produced is 12 MW. Neglect all other losses and the mass of the fuel
burned and take the specific heat as 1.01 kJ/kg K. Determine the thermal efficiency and
the mass flow of the air. (25% and 74.25 kg/s)




D.J.Dunn www.freestudy.co.uk 18