Sie sind auf Seite 1von 4

Engine Make & Model: P e rk in s 2 8 0 6 A -E 1 8 T A G 2

Circuit Breaker Type: 3 P o le A C B /M C C B


Fuel Tank Capacity: litre s (U S g a l)
1 0 0 0 (2 6 4 . 2 )
Frequency: 50 Hz 60 Hz
Fuel Consumption, Prime: l/h r (U S g a l/h r)
1 2 5 . 6 (3 3 . 2 ) -
Engine Speed: R P M
1 5 0 0 -
Alternator Model: L L 7 0 2 4 H
Base Frame Type: H e a v y D u ty F a b ric a te d S te e l
Fuel Consumption, Standby : l/h r (U S g a l/h r) 1 4 0 . 0 (3 7 . 0 ) -
Output Ratings
Generating Set Model S ta n d b y *
7 0 0 . 0 k V A
5 6 0 . 0 k W
-
-
P rim e *
6 3 5 . 0 k V A
5 0 8 . 0 k W
-
-
3 8 0 -4 1 5 V , 5 0 H z
* R e fe r to ra tin g s d e fin itio n s o n p a g e 4 .
R a tin g s a t p o w e r fa c to r.
0 . 8
GEP700-1
Technical Data
Diesel Generator Set
Exclusively from your Caterpillar dealer
6 . 3 (2 5 . 3 )
6 6 0 . 0 (2 3 3 0 8 )
Air Filter Type:
Combustion Air Flow:
m /m in (c fm ) -Standby:
-Prime:
Max. Combustion Air Intake
Restriction: k P a (in H
2
O )
R e p la c e a b le E le m e n t
- 3 6 . 7 (1 2 9 6 )
- 3 3 . 1 (1 1 6 9 )
-
Radiator Cooling Air Flow:
m /m in (c fm )
External Restriction to
Cooling Air Flow: P a (in H
2
O ) - 1 2 5 (0 . 5 )
-
Air System 60 Hz 50 Hz
Moment of Inertia: k g m (lb . in ) 7 . 4 4 (2 5 4 2 4 )
Governing Type:
Governing Class:
Compression Ratio:
Displacement: l (c u . in )
Engine Electrical System:
-Voltage/Ground:
-Battery Charger Amps:
Weight: k g (lb ) - Dry:
- Wet:
Cooling Method: Wa te r
E le c tro n ic
I S O 8 5 2 8 G 2
1 4 . 5 : 1
1 8 . 1 (1 1 0 4 . 5 )
Bore/Stroke: m m (in ) 1 4 5 . 0 (5 . 7 )/1 8 3 . 0 (7 . 2 )
2 4 /N e g a tiv e
7 0
2 0 5 0 (4 5 1 9 )
2 1 5 8 (4 7 5 8 )
Induction:
Manufacturer: P e rk in s
Model: 2 8 0 6 A -E 1 8 T A G 2
No. of Cylinders/Alignment: 6 / I n L in e
Cycle: 4 S tro k e
T u rb o c h a rg e d A ir T o A ir
C h a rg e C o o le d
- 2 0 . 0 Regenerative Power: k W
-Prime: 2 5 7 7 . 0 (3 7 3 . 7 ) -
- 2 7 7 1 . 0 (4 0 1 . 9 ) -Standby:
BMEP: k P a (p si)
- 5 8 4 . 0 (7 8 3 . 0 ) -Prime:
-Standby:
Gross Engine Power: k W (h p )
6 2 8 . 0 (8 4 2 . 0 ) -
- 1 5 0 0 Engine Speed: R P M
Oil Pan l (U S g a l):
Total Oil Capacity l (U S g a l):
Oil Filter Type:
Oil Type:
Cooling Method:
E c o , F u ll F lo w
5 5 . 5 (1 4 . 7 )
5 3 . 5 (1 4 . 1 )
A P I C H 4 / C I 4
Wa te r
Prime
50 Hz 6 5 . 0 (1 7 . 2 )
60 Hz - - - -
9 3 . 2 (2 4 . 6 ) 1 2 5 . 6 (3 3 . 2 ) 1 3 9 . 8 (3 6 . 9 )
(b a se d o n d ie se l fu e l w ith a sp e c ific g ra v ity o f 0 . 8 5 a n d c o n fo rm in g to
B S 2 8 6 9 , C la ss A 2 )
Recommended Fuel:
Fuel Consumption: l/h r (U S g a l/h r)
C la ss A 2 D ie se l
110%
Load
75%
Load
50%
Load
100%
Load
Fuel Filter Type: E c o R e p la c e a b le E le m e n t
Standby
50 Hz 7 0 . 6 (1 8 . 7 ) 1 0 2 . 9 (2 7 . 2 ) 1 4 0 . 0 (3 7 . 0 )
60 Hz - - -
Level: d B
Silencer System: k P a (in H g )
Pressure Drop Across
Silencer Noise Reduction
Silencer Type:
Pressure: k P a (in . H g )
Max. Allowable Back
-Prime:
m /m in (c fm ) -Standby:
Exhaust Gas Flow:
-Prime:
m /m in (c fm ) -Standby:
Exhaust Gas Temperature: C ( F )
S D 2 0 0 (1 ) Silencer Noise Reduction
- 0 . 2 5 (0 . 0 7 4 )
- 1 4
- 6 . 8 (2 . 0 )
- 1 2 3 . 0 (4 3 4 4 )
- 1 2 3 . 0 (4 3 4 4 )
- 5 6 3 (1 0 4 5 )
- 5 6 3 (1 0 4 5 )
L e v e l 1 Cooling System Capacity:
l (U S g a l)
Water Pump Type:
Heat Rejected to Water &
Lube Oil: k W (B tu /m in )
-Standby:
-Prime:
-Prime:
k W (B tu /m in ) -Standby:
Heat Radiation to Room:
Radiator Fan Load: k W (h p )
2 0 0 . 0 (1 1 3 7 4 )
-
- 6 1 . 0 (1 6 . 1 )
C e n trifu g a l
-
- 1 8 0 . 0 (1 0 2 3 6 )
- 4 0 . 5 (2 3 0 3 )
- 3 5 . 8 (2 0 3 6 )
8 . 0 (1 0 . 7 )
C o o lin g sy ste m d e sig n e d to o p e ra te in a m b ie n t c o n d itio n s u p to 5 0 C
(1 2 2 F ). C o n ta c t y o u r lo c a l O ly m p ia n d e a le r fo r p o w e r ra tin g s a t sp e c ific
site c o n d itio n s.
Cooling System 60 Hz 50 Hz
Performance 60 Hz 50 Hz
Fuel System
Exhaust System
Lubrication system Physical Data
Engine Techncial Data
C o n su lt y o u r O ly m p ia n re p re se n ta tiv e fo r m o re in fo rm a tio n
60 Hz 50 Hz
Data Item
50 Hz 60 Hz
Motor Starting
Capability* kVA
1 6 9 4 1 5 8 0 1 4 3 4 - - - - - -
Reactances:
Per Unit
Xd
X'd
X''d
3 . 0 7 0 3 . 3 0 0 3 . 6 6 0 - - - - - -
0 . 1 6 0 0 . 1 7 0 0 . 1 9 0 - - - - - -
0 . 1 2 5 0 . 1 3 5 0 . 1 4 9 - - - - - -
R e a c ta n c e s sh o w n a re a p p lic a b le to sta n d b y ra tin g s.
* B a se d o n 3 0 % v o lta g e d ip .
* * With o p tio n a l P e rm a n e n t M a g n e t g e n e ra to r o r A R E P e x c ita tio n .
4 1 5 /2 4 0 V 4 0 0 /2 3 0 V 3 8 0 /2 2 0 V
Short Circuit
Capacity** %
3 0 0 3 0 0 3 0 0 3 0 0 3 0 0 3 0 0 3 0 0 3 0 0 3 0 0
Manufacturer:
Model:
No. of Bearings:
Insulation Class:
Winding Pitch - Code:
Wires:
Ingress Protection Rating:
Excitation System:
AVR Model:
L L 7 0 2 4 H
1
H
2 /3 - 6 S
6
I P 2 3
A R E P
R 4 4 8
Overspeed: R P M
Voltage Regulation (steady state) (%):
Wave Form NEMA = TIF:
Wave Form IEC = THF:
Total Harmonic Content LL/LN:
Radio Interference:
Radiant Heat: kW (Btu/min)
-5 0 H z:
-6 0 H z:
S u p re ssio n is in lin e w ith E u ro p e a n
S ta n d a rd E N 6 1 0 0 0 -6
-
36.6 (2081)
4.0%
2.0%
50
+ /- 0.5
2250
Physical Data Operating Data
Alternator Performance Data
Alternator Technical Data
C o n su lt y o u r O ly m p ia n re p re se n ta tiv e fo r m o re in fo rm a tio n
O L Y M P I A N
5 6 0 . 0 7 0 0 . 0
5 6 0 . 0 7 0 0 . 0
5 6 0 . 0 7 0 0 . 0
kW kVA
5 0 8 . 0 6 3 5 . 0
6 3 5 . 0 5 0 8 . 0
kW kVA
3 8 0 /2 2 0 V
4 1 5 /2 4 0 V
4 0 0 /2 3 0 V
5 0 8 . 0 6 3 5 . 0
Technical Data
Phase Ratings and Performance at 50 Hz, RPM 1500 3
Voltage P rim e S ta n d b y
Standby Rating
T h e se ra tin g s a re a p p lic a b le fo r su p p ly in g c o n tin u o u s e le c tric a l
p o w e r (a t v a ria b le lo a d ) in th e e v e n t o f a u tility p o w e r fa ilu re . N o
o v e rlo a d is p e rm itte d o n th e se ra tin g s. T h e a lte rn a to r o n th is m o d e l
is p e a k c o n tin u o u s ra te d (a s d e fin e d in I S O 8 5 2 8 -3 ).
Prime Rating
T h e se ra tin g s a re a p p lic a b le fo r su p p ly in g c o n tin u o u s e le c tric a l
p o w e r (a t v a ria b le lo a d ) in lie u o f c o m m e rc ia lly p u rc h a se d p o w e r.
T h e re is n o lim ita tio n to th e a n n u a l h o u rs o f o p e ra tio n a n d th is
m o d e l c a n su p p ly 1 0 % o v e rlo a d p o w e r fo r 1 h o u r in 1 2 h o u rs.
Standard Reference Conditions
N o te : S ta n d a rd re fe re n c e c o n d itio n s 2 5 C (7 7 F ) a ir in le t te m p ,
1 0 0 m (3 2 8 ft) A . S . L . 3 0 % re la tiv e h u m id ity . F u e l c o n su m p tio n d a ta
a t fu ll lo a d w ith d ie se l fu e l w ith sp e c ific g ra v ity o f 0 . 8 5 a n d
c o n fo rm in g to B S 2 8 6 9 : 1 9 9 8 , C la ss A 2 .
Definitions
kW kVA kW kVA
Phase Ratings and Performance at 60 Hz, RPM - 3
Voltage P rim e S ta n d b y
Weights & Dimensions
Weights: kg (lb)
Net (+ lube oil)
Wet (+ lube oil & coolant)
Fuel, lube oil & coolant 6 0 1 1 (1 3 2 5 2 )
4 8 7 0 (1 0 7 3 6 )
4 8 0 0 (1 0 5 8 2 )
Dimensions: mm (in)
Height
Width
Length
2 2 4 6 (8 8 . 4 )
1 5 3 6 (6 0 . 5 )
4 1 1 1 (1 6 1 . 9 )
Documents
A fu ll se t o f o p e ra tio n a n d m a in te n a n c e m a n u a ls a n d c irc u it w irin g
d ia g ra m s.
Quality Standards
B S 4 9 9 9 , B S 5 0 0 0 , B S E N 6 0 0 3 4 , B S E N 6 1 0 0 0 , I E C 6 0 0 3 4 .

Warranty
A ll e q u ip m e n t c a rrie s fu ll m a n u fa c tu re r' s w a rra n ty .

General Data
M a rk e t: I n te rn a tio n a l

I n fo rm a tio n c o n ta in e d in th is p u b lic a tio n m a y b e c o n sid e re d c o n fid e n tia l.
D isc re tio n is re c o m m e n d e d w h e n d istrib u tin g .
M a te ria ls a n d sp e c ific a tio n s a re su b je c t to c h a n g e w ith o u t n o tic e .
C A T , C A T E R P I L L A R , th e ir re sp e c tiv e lo g o s a n d ' ' C a te rp illa r Y e llo w ' ' , a s w e ll a s c o rp o ra te a n d p ro d u c t
id e n tity u se d h e re in , a re tra d e m a rk s o f C a te rp illa r a n d m a y n o t b e u se d w ith o u t p e rm issio n .
w w w . C A T -E le c tric P o w e r. c o m
2 0 0 9 C a te rp illa r
A ll rig h ts re se rv e d .
P rin te d in U . S . A .
Note: G e n e ra l c o n fig u ra tio n n o t to b e u se d
fo r in sta lla tio n . S e e g e n e ra l d im e n sio n
d ra w in g s fo r d e ta il.
-
LEHF8848-01 (03/09)

Das könnte Ihnen auch gefallen