Important Notice on Product Safety Elevated voltages are inevitably present at specific points in this electrical equipment. Non-observance of these conditions and the safety instructions can result in personal injury or in property damage. Only trained and qualified personnel may install and maintain the system.
Important Notice on Product Safety Elevated voltages are inevitably present at specific points in this electrical equipment. Non-observance of these conditions and the safety instructions can result in personal injury or in property damage. Only trained and qualified personnel may install and maintain the system.
Important Notice on Product Safety Elevated voltages are inevitably present at specific points in this electrical equipment. Non-observance of these conditions and the safety instructions can result in personal injury or in property damage. Only trained and qualified personnel may install and maintain the system.
Output Manual OML:Non Standard Maintenance A50023-X4005-A2-4-7619 2 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 f Important Notice on Product Safety Elevated voltages are inevitably present at specific points in this electrical equipment. Some of the parts may also have elevated operating temperatures. Non-observance of these conditions and the safety instructions can result in personal injury or in prop- erty damage. Therefore, only trained and qualified personnel may install and maintain the system. The systemcomplies with the standard EN 60950 / IEC 60950. All equipment connected has to comply with the applicable safety standards. The same text in German: Wichtiger Hinweis zur Produktsicherheit In elektrischen Anlagen stehen zwangslufig bestimmte Teile der Gerte unter Spannung. Einige Teile knnen auch eine hohe Betriebstemperatur aufweisen. Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Krperverletzungen und Sachschden fhren. Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiert und wartet. Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene Gerte mssen die zutreffenden Sicherheitsbestimmungen erfllen. Trademarks: All designations used in this document can be trademarks, the use of which by third parties for their own purposes could violate the rights of their owners. Copyright (C) Siemens AG 2003-2003. Issued by the Information and Communication Networks Group Hofmannstrae 51 D-81359 Mnchen Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract. A50023-X4005-A2-4-7619 3 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance Issues Change indications (Ind.): N = new; G = modied; 0 = deleted; Document Title Page(s) Issue/Ind. MMN:UMR 3.0 . . . . . . . . 1... 54 4/ N This document consists of a total of 54 Pages. Issue History Issue Number Date of Is- sue Reason for Update Draft1 Jan. 2003 First Draft release. 1 2 3 4 Dec. 2003 FEKAT correction CU9965 4 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 A50023-X4005-A2-4-7619 5 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1.1 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2 Alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2.1 Time of Network Element out of sync with OMC (500) . . . . . . . . . . . . . . . . . 9 2.2 SW Recovery Action (501) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2.3 Disk Generic HW Error (502) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 2.4 Mirror/SubMirror Failure (503) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 2.5 MetaDb Failure (504) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.6 Threshold Crossed (505) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.7 OMT-OMP Communication Failure (OMT) (506) . . . . . . . . . . . . . . . . . . . . 15 2.8 Disconnected BSS (507). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 2.9 1 O-Link Down (508). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 2.10 LAN Card Failure (509). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 2.11 Possible Fault on a HSI Communication Board (510) . . . . . . . . . . . . . . . . 19 2.12 Possible Fault on a PCM Communication Board (511) . . . . . . . . . . . . . . . 20 2.13 PCM Switch Failure (512) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 2.14 External Alarm Device Failure (513) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 2.15 Log Instance Reached Warning Threshold (514) . . . . . . . . . . . . . . . . . . . . 23 2.16 Log Instance Reached Minor Threshold (515) . . . . . . . . . . . . . . . . . . . . . . 24 2.17 Log Instance Reached Major Threshold (516) . . . . . . . . . . . . . . . . . . . . . . 25 2.18 Log Instance Reached Critical Threshold (517) . . . . . . . . . . . . . . . . . . . . . 26 2.19 The Agent Has Hit Configured Threshold Level (518) . . . . . . . . . . . . . . . . 27 2.20 The MPA has Hit Configured Threshold Level (519) . . . . . . . . . . . . . . . . . 28 2.21 B-Link Corba Disconnected (520). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 2.22 R-Link CMISE Disconnected (521) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 2.23 SubMirror Resyncing (522) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 2.24 Network Unavailable (523) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 2.25 The nbManagedElementId Received doesnt Match the NodeB Configuration within RC (524) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 2.26 SubMirror Failure (525). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 2.27 Alignment Procedure Failed (527) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 2.28 OMP-OMP Communication failure (OMP) (528). . . . . . . . . . . . . . . . . . . . . 36 2.29 NetViewer Server indeterminate notification (529) . . . . . . . . . . . . . . . . . . . 37 2.30 NetViewer Server critical notification (530) . . . . . . . . . . . . . . . . . . . . . . . . . 38 2.31 NetViewer Server major notification (531) . . . . . . . . . . . . . . . . . . . . . . . . . 39 2.32 NetViewer Server minor notification (532) . . . . . . . . . . . . . . . . . . . . . . . . . 40 2.33 NetViewer Server warning notification (533). . . . . . . . . . . . . . . . . . . . . . . . 41 2.34 NetViewer Connection Map Under Configuration (534) . . . . . . . . . . . . . . . 42 2.35 NetViewer Connection Down (535). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 2.36 Local SMLC state file does not exist! (536) . . . . . . . . . . . . . . . . . . . . . . . . 44 3 Notifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 3.1 serviceResponse (RC_LOG) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 3.2 serviceResponse (SbsOcm:session) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 3.3 serviceFailure (RC_LOG) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 3.4 serviceFailure (SbsOcm:session) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 6 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 3.5 unauthorizedAccessAttempt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 3.6 sbsOimFileTransferControl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 3.7 outOfHoursActivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 3.8 authenticationFailure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 4 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 4.1 Specific Problems for the Alarm List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 A50023-X4005-A2-4-7619 7 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 1 Introduction The goal of this manual is to describe all alarms and systeminformations which can gen- erated by the Radio Commander. The software attempts to provide a precise error description for each alarm containing all informations for the operator and manufacturer for rapid localization, investigation and elimination of the fault. There is no relation between the number of described faults and their frequency of occurrence in the system. This manual is organized according to the error ID's. Error ceased messages clears all alarms for a certain probable cause of one object. Error ID: Shows the Error ID for the notification MOC: Identifies the managed object class of the fault or error. Version: Format not yet defined. Error information: This gives a detailed overview about the occurred error: <eventType> Values: communicationAlarm environmentalAlarm equipmentAlarm qualityOfServiceAlarm processingErrorAlarm <probableCause> Identies the probable cause of the fault or error. The probable cause is taken out of a predened set of values dened for each alarm type. <specicProblems> This is a short description of the error. <perceivedSeverity> According to the CCITT Rec. X.733 all alarmnotications produced in switching sys- tems have to be classied concerning the severity of their impact on the NE's func- tionality. Values: indeterminate, critical, major, minor, warning <tresholdInfo> Gives information about the reached threshold. <monitoredAttributes> Currently not used. <additionalText> This eld will be used to give reason for the occurred error/event. According to CCITT X.733 this part, when present, allows a free form text description to be re- ported. 8 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 Immediate defense action: This section describes the defense action accomplished by the software every time the particular Failure Event occurs. The defense action is accomplished to attempt to solve or at least to overcome the problem. n.a. is reported if no defense action is associated to the Failure Event. Proposed repair actions: Describes the actions the operator must perform to attempt to solve the problem. Every time that a diagnostic on a faulty object fails, the operator has to replace the faulty module (specified in the Test Report) following the procedure described in the according maintenance manual. Error description: Concise description of the probable cause of the error. 1.1 Abbreviations Abbr. Meaning BSC Base Station Controller BSS Base Station Subsystems CLI Command Line Interface GUI Graphical User Interface LAN Local Area Network LMT Local Maintenance Terminal (m) Value is mandatory MOC Managed Object Class MSC Mobile Services Switching Center n.a. Not available NE Network Element (o) Value is optional OMP Operating and Maintenance Processor OMT Operating and Maintenance Terminal PCM Puls Code Modulation RC Radio Commander SMLC Serving Mobile Location Center WAN Wide Area Network Tab. 1.1 Abbreviations A50023-X4005-A2-4-7619 9 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 2 Alarms 2.1 Time of Network Element out of sync with OMC (500) Error ID: 500 MOC: DNODEB, DRNC, DBSS Version: n.a. Error information: <eventType> equipmentAlarm <probableCause> gsmClockSynchronisa- tionProblem <specificProblems> Time of Network Element out of sync with OMC <perceivedSeverity> warning <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> reason: NE time is out of sync with RCtime, NEtime set. Date and Time: outOfSyncBy: Immediate defense action: n.a. Proposed repair ac- tions: No action required Error description: The error is generated in case the BSC, RNC or NodeN clock is not synchronized with the OMP clock. Periodic time check must be activated explicitly from GUI or CLI session. At the configured time intervals, OMP checks whether the clock of each NE connected is synchronized with the OMP. If the difference is bigger than a predefined threshold, then date & time of the BSC, RNCor NodeB are set and this error is gen- erated. Note: at the time the O-link, Ift-R or Itf B connection is estab- lished, date & time of the BSC, RNC or NodeB are set without generating an alarm, even if the threshold was exceeded 10 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 2.2 SW Recovery Action (501) Error ID: 501 MOC: OMP, OMT Version: n.a. Error information: <eventType> processingErrorAlarm <probableCause> softwareProgramAbnormallyTer- minated <specificProblems> SW recovery action <perceivedSeverity> warning <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> <the individual recovery informa- tion (what will be recovered)> Immediate defense action: n.a. Proposed repair ac- tions: no repair action necessary - automatic recovery, take alarmas notice Error description: RC initiates autonomous SW recovery action A50023-X4005-A2-4-7619 11 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 2.3 Disk Generic HW Error (502) Error ID: 502 MOC: HDD Version: n.a. Error information: <eventType> equipmentAlarm <probableCause> gsmDiskProblem <specificProblems> Disk Generic HW Error <perceivedSeverity> critical <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: Try to make a back-up of all data. Proposed repair ac- tions: 1.Locate the effected disk. 2.Contact local SUN service or local staff to replace the faulty disk and provide the following information: Effected OMP. Type of effected disk. 3.Make sure that after have replaced the disk the related alarm is ceased. If the alarm after few minutes is still active contact local SUN service or local staff. Otherwise give hddReplace command available on CLI/GUI. Error description: A physical error was detected in the hard disk.The following cases are possible: OMP failure on disk with system software No redundancy/mirroring, only one disk May be that the RC stops working. Then it is not longer possi- ble to access/maintain of the RC and the connected radio sub- systems. Redundancy/mirroring, two or more disks The system switches automatically to redundant disk. The system and RC will continue working. OMP failure on disk with RC data No redundancy/mirroring, only one disk The RC stops working immediately. It is not longer possible to access/maintain of the RC and the connected radio sub- systems. Redundancy/mirroring, two or more disks The system switches automatically to redundant disk. The system and RC will continue working. 12 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 2.4 Mirror/SubMirror Failure (503) Error ID: 503 MOC: DATAUNIT Version: n.a. Error information: <eventType> equipmentAlarm <probableCause> gsmDiskProblem <specificProblems> Mirror/SubMirror failure <perceivedSeverity> critical <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: 1. Locate the effected disk on OMP: execute metastat and metadb SDS maintenance commands to see what is/are the specific problemwithin Solstice Disk Suite Object (Mirror/Sub- mirror). See Solstice Disksuite 4.2 User's Guide for further de- tails. 2. Contact local SUN service or local staff. Provide the error message and exact information fromthe pre- vious step. Error description: Solstice Disk Suite Object (Mirror/Submirror) malfunction. A50023-X4005-A2-4-7619 13 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 2.5 MetaDb Failure (504) Error ID: 504 MOC: DISKLAYOUT Version: n.a. Error information: <eventType> equipmentAlarm <probableCause> gsmDatabaseInconsistency <specificProblems> MetaDb failure <perceivedSeverity> critical <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: 1.Locate the affected meta DB replicas on OMP: execute metadb SDS maintenance command to see what is/are the specific problem within Solstice Disk Suite Object (meta DB Replicas). See Solstice Disksuite 4.2 User's Guide for further details. 2.Contact local SUN service or local staff. It is necessary to reconfigure the MetaDB. Provide the error message and exact information about your system. Error description: Solstice Disk Suite Object (MetaDB Replica) malfunction on OMP. RC could will stop working soon. 14 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 2.6 Threshold Crossed (505) Error ID: 505 MOC: DATAUNIT Version: n.a. Error information: <eventType> processingErrorAlarm <probableCause> gsmSystem ResourcesOverload <specificProblems> Threshold crossed <perceivedSeverity> major <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: Do not write on this Data Unit anymore, until related alarm ceases. Proposed repair ac- tions: 1.) Perform fault clearance task T-15 Checking available disk space to collect information. 2.) Free some space on the involved data unit (for example de- lete old files) or expand the quota assigned to the involved data unit (for example adding a new disk to the system), using information collected from previous step. Error description: The involved data unit of type equal to ufs has crossed the re- lated threshold. A50023-X4005-A2-4-7619 15 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 2.7 OMT-OMP Communication Failure (OMT) (506) Error ID: 506 MOC: OMT Version: n.a. Error information: <eventType> communicationsAlarm <probableCause> gsmLinkFailure <specificProblems> OMT-OMP communication failure (OMT) <perceivedSeverity> critical <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: 1. Check the network cable of the OMT: Are the network cable plugs inserted correctly into the sockets at both ends? 2. Check the network connection to OMT from an UNIX shell in the primary OMP with the following command: ping <omt_name> If the network connection is OK, the OMT will acknowledge. 3. Check whether OMT is shutdown. If there is still no connection between OMT and OMP contact your local staff. Error description: A communication failure is detected on connection with the OMT. 16 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 2.8 Disconnected BSS (507) Error ID: 507 MOC: OLINK Version: n.a. Error information: <eventType> communicationsAlarm <probableCause> gsmLinkFailure <specificProblems> Disconnected BSS <perceivedSeverity> critical <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: 1.) Check whether there is only one, several or all BSS resp. BSC concerned. 2.) Performfault clearance tasks T-26 Checking X.25 configu- ration, T-27 Checking X.25 link status, T-28 Tracing an X.25 link, and T-32 Checking status of PCMcard or T-33 Checking status of HSI ports. 3.) Check plugs and HSI or PCM card on the OMP using the corresponding manuals. 4.) Check the following processes: osinetd, osimcsd, em_cmip, x25netd 5.) Check failed BSC status from LMT. Error description: The BSS is disconnected. There are three possibilities where the connection between BSS and OMP can be disturbed. This depends on how the BSS is connected to the OMP: - Direct link between OMP and BSS using HSI card (A) - WAN link between OMP and BSS using HSI card - PCM (nailed-up) link: connection from OMP to MSC using Sprite card (B) - PCM (nailed-up) link: connection from MSC to BSS (C) A50023-X4005-A2-4-7619 17 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 2.9 1 O-Link Down (508) Error ID: 508 MOC: OLINK Version: n.a. Error information: <eventType> communicationsAlarm <probableCause> gsmLost Redundancy <specificProblems> 1 O-link down <perceivedSeverity> major <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: 1.) Check physical connection. 2.) If available check the Sprite card and Sprite port. 3.) Perform fault clearance task T-26 Checking X.25 configu- ration, T-27 Checking X.25 link status, T-28 Tracing an X.25 link. 4.) Check osinetd process. 5.) Check ftcserver.luc process. 6.) Check failed BSC status from LMT. Error description: The Olink redundancy is lost. The specified Olink is discon- nected. 18 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 2.10 LAN Card Failure (509) Error ID: 509 MOC: OMP Version: n.a. Error information: <eventType> communicationsAlarm <probableCause> gsmEquipmentFailure <specificProblems> LAN Card Failure <perceivedSeverity> major <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: Check network connections of the OMP: Are the network cable plugs inserted correctly into the sockets at both ends? If the plugs are inserted correctly this alarm means that one lan card is faulted. Then contact your local staff providing the error message and exact information about your OMP. If the plugs aren't inserted correctly, plug themin. Note that for this version of RC the emitted alarm will not be cleared. Error description: On Extended Redundant OMP one lan card (or network con- nection) is faulted. OMP switched to redundant lan card and emitted this alarmto indicate this situation. A50023-X4005-A2-4-7619 19 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 2.11 Possible Fault on a HSI Communication Board (510) Error ID: 510 MOC: HSI_CARD Version: n.a. Error information: <eventType> communicationsAlarm <probableCause> gsmEquipmentFailure <specificProblems> Possible Fault on a HSI Communi- cation Board <perceivedSeverity> critical <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: 1.) Check plugs and HSI card on the OMP using the corre- sponding manuals. 2.) Check the following processes: osinetd, osimcsd, em_cmip, x25netd 3.) Performfault clearance tasks T-26 Checking X.25 configu- ration, T-27 Checking X.25 link status, T-28 Tracing an X.25 link, and T-33 Checking status of HSI ports. 4.) Contact your local staff to check the cables and the HSI card itself using the corresponding manual. Provide the alarm number and message and exact information fromthe previous step. Error description: All OLinks which are connected to the same HSI card became faulty. 20 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 2.12 Possible Fault on a PCM Communication Board (511) Error ID: 511 MOC: SPRITE_CARD Version: n.a. Error information: <eventType> communicationsAlarm <probableCause> gsmEquipmentFailure <specificProblems> Possible Fault on a PCM Commu- nication Board <perceivedSeverity> critical <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: 1.) Check plugs and PCM Card on the OMP using the corre- sponding manuals. 2.) Check the following processes: osinetd, osimcsd, em_cmip, x25netd 3.) Performfault clearance tasks T-26 Checking X.25 configu- ration, T-27 Checking X.25 link status, T-28 Tracing an X.25 link, and T-33 Checking status of HSI ports. 4.) Contact your local staff to check the cables and the Sprite card itself using the corresponding manual. Provide the alarm number and message and exact information fromthe previous step. Error description: All OLinks which are connected to the same PCM card be- came faulty. A50023-X4005-A2-4-7619 21 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 2.13 PCM Switch Failure (512) Error ID: 512 MOC: OMP Version: n.a. Error information: <eventType> communicationsAlarm <probableCause> gsmEquipmentFailure <specificProblems> PCM Switch failure <perceivedSeverity> critical <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: Contact your local staff to check the cables plugged in correct- ly: FromOMP to PCMSwitch and fromPCMSwitch to the net- work using the correspondent manual. Error description: PCMSwitch failure. The connection fromOMP to PCMSwitch (so called Selector Unit) or fromPCMSwitch to the network is disturbed. 22 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 2.14 External Alarm Device Failure (513) Error ID: 513 MOC: EXT_ALARM_DEVICE Version: n.a. Error information: <eventType> equipmentAlarm <probableCause> gsmEquipmentFailure <specificProblems> External Alarm Device Failure <perceivedSeverity> major <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: 1. Check the components of the alarm device panel (e.g. lamp(s), siren) using the corresponding manual. 2. Check the cables whether they are plugged in correctly and into the correct ports. Error description: A fault occurred on External Alarm Device Panel. A50023-X4005-A2-4-7619 23 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 2.15 Log Instance Reached Warning Threshold (514) Error ID: 514 MOC: RC_LOG Version: n.a. Error information: <eventType> processingErrorAlarm <probableCause> Storage Capacity Problem <specificProblems> Log instance reached warning threshold <perceivedSeverity> warning <thresholdInfo> triggeredThreshold:"SbsOim":sb- sOimCapacityAlarmThreshold observedValue: integer (an addi- tional capacity alarm threshold ex- ceeded) <monitoredAttributes> attributeId: "SbsOim":sbsOimMax- LogSizeMegaByte attributeValue: integer (max log size of the log instance expressed in MegaByte) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: 1.) Increase the size (maxLogSize parameter) of the alarmed log instance. 2.) Increase the additional threshold value of the alarmed log instance. Error description: An additional capacity threshold has been reached or exceed- edby the log instance. 24 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 2.16 Log Instance Reached Minor Threshold (515) Error ID: 515 MOC: RC_LOG Version: n.a. Error information: <eventType> processingErrorAlarm <probableCause> Storage Capacity Problem <specificProblems> Log instance reached minor thres- hold <perceivedSeverity> minor <thresholdInfo> triggeredThreshold:"SbsOim":sb- sOimCapacityAlarmThreshold observedValue: integer (mi- norThreshold or capacity alarm threshold exceeded) <monitoredAttributes> attributeId: "SbsOim":sbsOimMax- LogSizeMegaByte attributeValue: integer (max log size of the log instance expressed in MegaByte) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: 1.) Increase the size (maxLogSize parameter) of the alarmed log instance. 2.) Increase the minor threshold value of the alarmed log in- stance. Error description: A minor capacity threshold has been reached or exceeded by the log instance named. A50023-X4005-A2-4-7619 25 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 2.17 Log Instance Reached Major Threshold (516) Error ID: 516 MOC: RC_LOG Version: n.a. Error information: <eventType> processingErrorAlarm <probableCause> Storage Capacity Problem <specificProblems> Log instance reached major thresh- old <perceivedSeverity> major <thresholdInfo> triggeredThreshold:"SbsOim":sb- sOimCapacityAlarmThreshold observedValue: integer (ma- jorThreshold or capacity alarm threshold exceeded) <monitoredAttributes> attributeId: "SbsOim":sbsOimMax- LogSizeMegaByte attributeValue: integer (max log size of the log instance expressed in MegaByte) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: 1.) Increase the size (maxLogSize parameter) of the alarmed log instance. 2.) Increase the major threshold value of the alarmed log in- stance. Error description: A major capacity threshold has been reached or exceeded by the log instance named. 26 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 2.18 Log Instance Reached Critical Threshold (517) Error ID: 517 MOC: RC_LOG Version: n.a. Error information: <eventType> processingErrorAlarm <probableCause> Storage Capacity Problem <specificProblems> Log instance reached critical threshold <perceivedSeverity> critical <thresholdInfo> triggeredThreshold:"SbsOim":sb- sOimCapacityAlarmThreshold observedValue: integer (criticalTh- reshold or capacity alarmthreshold exceeded) <monitoredAttributes> attributeId: "SbsOim":sbsOimMax- LogSizeMegaByte attributeValue: integer (max log size of the log instance expressed in MegaByte) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: 1.) Increase the size (maxLogSize parameter) of the alarmed log instance. 2.) Increase the critical threshold value of the alarmed log in- stance. 3.) If the log full condition has been reached set the logFullAc- tion to wrap for going on writing log records by dropping the oldest ones. Error description: A critical capacity threshold has been reached/exceeded by the log instance or a log full condition has occurred. A50023-X4005-A2-4-7619 27 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 2.19 The Agent Has Hit Congured Threshold Level (518) Error ID: 518 MOC: RC Version: n.a. Error information: <eventType> processingErrorAlarm <probableCause> Threshold Crossed <specificProblems> The agent has hit configured threshold level <perceivedSeverity> minor <thresholdInfo> thresholdLevel: integer <monitoredAttributes> (o) <additionalText> The agent has hit certain threshold level Immediate defense action: n.a. Proposed repair ac- tions: If critical threshold was crossed, then the operator has three possibilities: 1. Turn on automatic overload (if it was not activated yet), then the link to the overloaded agent will be automatically locked af- ter the critical threshold was crossed (Alternative 1) 2. Turn off automatic overload handling (if it was not deactivat- ed yet), then he has the possibility to use (Alternative 2), but be aware, the system can be really overloaded. 3. Re-configure the overload parameters (Alternative 3), but be aware, because the system can be really overloaded. Error description: An agent (BSS or RNS) has crossed the pre-configured threshold level of events-per-agent. The overload handling is implemented in the MPA (Message Protocol Adapter) and it offers 4 threshold levels (warning, mi- nor, major, critical - selectable during installation or frommain- tenance terminal) for check the overload situation on the links or on the MPA itself. In overload situation one alarmis emitted with severity for the corresponding thresholds level. 28 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 2.20 The MPA has Hit Congured Threshold Level (519) Error ID: 519 MOC: RC Version: n.a. Error information: <eventType> processingErrorAlarm <probableCause> Threshold Crossed <specificProblems> The MPA has hit configured thresh- old level <perceivedSeverity> minor <thresholdInfo> thresholdLevel: integer <monitoredAttributes> (o) <additionalText> The agent has hit certain threshold level Immediate defense action: n.a. Proposed repair ac- tions: If critical threshold was crossed, then the operator has three possibilities: 1. Turn on automatic overload (if it was not activated yet), then the link to the overloaded agent will be automatically locked af- ter the critical threshold was crossed. 2. Turn off automatic overload handling (if it was not deactivat- ed yet), then he has the possibility to use, but be aware, the system can be really overloaded. 3. Re-configure the overload parameters, but be aware, be- cause the system can be really overloaded. Error description: An MPA (Message Protocol Adapter) has crossed the pre- configured threshold level of events-per-MPA. The overload handling is implemented in the MPA and it offers 4 threshold levels (warning, minor, major, critical - selectable during installation or frommaintenance terminal) for check the overload situation on the links or on the MPA itself. In overload situation one alarmis emitted with severity for the correspond- ing thresholds level. A50023-X4005-A2-4-7619 29 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 2.21 B-Link Corba Disconnected (520) Error ID: 520 MOC: ITFB Version: n.a. Error information: <eventType> communicationsAlarm <probableCause> Link Failure <specificProblems> B-link Corba disconnected <perceivedSeverity> critical <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: Check Network connection. Error description: n.a. 30 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 2.22 R-Link CMISE Disconnected (521) Error ID: 521 MOC: ITFR Version: n.a. Error information: <eventType> communicationsAlarm <probableCause> gsmEquipmentFailure <specificProblems> R-link CMISE disconnected <perceivedSeverity> critical <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: Check network connections of the OMP: Are the network cable plugs inserted correctly into the sockets at both ends? If not, plug them in; the network connection will establish itself within a few seconds. If the plugs are inserted correctly or network connection doesn't establish then contact your local staff providing the er- ror message and exact information about your OMP. Error description: OMP has no access to the LAN ( lan card(s) or network con- nection(s) are faulted). This alarm will only appear on the OMT running on the OMP. The following scenarios can be the reason for this alarm: - complete RNC outage - restart of the RNC - FE problems on RNC - LAN problems A50023-X4005-A2-4-7619 31 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 2.23 SubMirror Resyncing (522) Error ID: 522 MOC: DATAUNIT Version: n.a. Error information: <eventType> equipmentAlarm <probableCause> gsmDiskProblem <specificProblems> SubMirror Resyncing <perceivedSeverity> major <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: No Action. Error description: Solstice DiskSuite Submirror is resyncing, i.e. there are data transferred fromone part of a mirror to the other, normally after replacing a faulty disk. The duration of resyncing depends on the disk capacity and the amount of stored data. It can take more than one hour. Working with the Radio Commander is not affected. 32 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 2.24 Network Unavailable (523) Error ID: 523 MOC: OMP Version: n.a. Error information: <eventType> communicationsAlarm <probableCause> gsmEquipmentFailure <specificProblems> Network unavailable <perceivedSeverity> critical <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: 1.) Check network connections of the OMP: 2.) Are the network cable plugs inserted correctly into the sockets at both ends? If not, plug themin; the network connec- tion will establish itself within a few seconds. 3.) If the plugs are inserted correctly or network connection doesn't establish then contact your local staff providing the er- ror message and exact information about your OMP. Error description: OMP has no access to the LAN ( lan card(s) or network con- nection(s) are faulted). This alarm will only appear on the OMT running on the OMP. A50023-X4005-A2-4-7619 33 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 2.25 The nbManagedElementId Received doesnt Match the NodeB Conguration within RC (524) Error ID: 524 MOC: ITFB, ITFR Version: n.a. Error information: <eventType> communicationsAlarm <probableCause> Configuration or Customization Er- ror <specificProblems> The nbManagedElementId re- ceived doesn't match the NodeB configuration within RC <perceivedSeverity> critical <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: Reconfigure B-Link with correct IOR of the NodeB. Error description: n.a. 34 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 2.26 SubMirror Failure (525) Error ID: 525 MOC: DATAUNIT Version: n.a. Error information: <eventType> equipmentAlarm <probableCause> gsmLostRedundancy <specificProblems> SubMirror failure <perceivedSeverity> major <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: Depending on the occurred error condition, following actions can be undertaken: - Condition 1: also alarms on all HDDs belonging to an exter- nal disk channel are active Repair action: check physical connection of the external disk channel to the system. If disconnected then re-connect it to the system. If a HDD is defect replace it. Wait until all hdd be- longing to the re-connected channel alarms are ceased. Then give first disablediskmirror and then enablediskmirror com- mands available on CLI/GUI. - Condition 2: also an alarmon a hdd which data unit instance belong to is active. Repair action: physically replace faulted hard disk or re-con- nect it to the related channel, then give hddReplace command available on CLI/GUI. - Condition 3: no alarmon a HDD which data unit instance be- long to is active. Locate the effected SDS object (Mirror/Submirror) disk: exe- cute metastat and metadb SDS maintenance commands to see what is/are the specific problem. See Solstice Disksuite 4.2 User's Guide for further details. Then Contact local SUN service or local staff, providing the er- ror message and exact information about your system above retrieved. Error description: Lost of redundancy of a Data unit instance. This error occurred only in a mirrored disk layout configuration and it can be due to a logical error to an SDS object or to a physical fault. A50023-X4005-A2-4-7619 35 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 2.27 Alignment Procedure Failed (527) Error ID: 527 MOC: sbsTrauEquipment, sbsBtsePico, sbsBtseP, sbsBtseEM, sb- sBtsE, sbs3gManagedElement, nbManagedElement, nb2ManagedElement (all alarms generate locally at Radio Commander) Version: n.a. Error information: <eventType> processingErrorAlarm <probableCause> Software Program Abnormally <specificProblems> Alignment Procedure Failed <perceivedSeverity> warning <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: Try re-aligning using commands. Error description: An error occurred during an alignment phase 36 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 2.28 OMP-OMP Communication failure (OMP) (528) Error ID: 528 MOC: OMP Version: n.a. Error information: <eventType> communicationsAlarm <probableCause> gsmLinkFailure <specificProblems> OMP-OMP Communication failure (OMP) <perceivedSeverity> critical <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: 1. Check the network cable of the OMP: Are the network cable plugs inserted correctly into the sockets at both ends? 2. Check the network connection to OMP from an UNIX shell in the primary OMP with the following command: ping <omp_name> If the network connection is OK, the OMP will acknowledge. 3. Check whether OMP is shutdown. If there is still no connec- tion between primary OMP and another OMP contact your lo- cal staff. Error description: A communication failure is detected on connection with other OMP. A50023-X4005-A2-4-7619 37 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 2.29 NetViewer Server indeterminate notication (529) Error ID: 529 MOC: OimMicrowavesEquipment Version: n.a. Error information: <eventType> equipmentAlarm <probableCause> Equipment Failure <specificProblems> NetViewer Server indeterminate notification <perceivedSeverity> indeterminate <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: Open NetViewer to get more details on the NetViewer equip- ment state/status. Error description: An equiment notification of indeterminate severity received. 38 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 2.30 NetViewer Server critical notication (530) Error ID: 530 MOC: OimMicrowavesEquipment Version: n.a. Error information: <eventType> equipmentAlarm <probableCause> Equipment Failure <specificProblems> NetViewer Server critical notifica- tion <perceivedSeverity> critical <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: Open NetViewer to get more details on the NetViewer equip- ment state/status. Error description: An equiment notification of critical severity received. A50023-X4005-A2-4-7619 39 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 2.31 NetViewer Server major notication (531) Error ID: 531 MOC: OimMicrowavesEquipment Version: n.a. Error information: <eventType> equipmentAlarm <probableCause> Equipment Failure <specificProblems> NetViewer Server major notification <perceivedSeverity> major <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: Open NetViewer to get more details on the NetViewer equip- ment state/status. Error description: An equiment notification of major severity received. 40 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 2.32 NetViewer Server minor notication (532) Error ID: 532 MOC: OimMicrowavesEquipment Version: n.a. Error information: <eventType> equipmentAlarm <probableCause> Equipment Failure <specificProblems> NetViewer Server minor notifica- tion) <perceivedSeverity> minor <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: Open NetViewer to get more details on the NetViewer equip- ment state/status. Error description: An equiment notification of minor severity received. A50023-X4005-A2-4-7619 41 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 2.33 NetViewer Server warning notication (533) Error ID: 533 MOC: OimMicrowavesEquipment Version: n.a. Error information: <eventType> equipmentAlarm <probableCause> Equipment Failure <specificProblems> NetViewer Server warning notifica- tion <perceivedSeverity> warning <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: Open NetViewer to get more details on the NetViewer equip- ment state/status. Error description: An equiment notification of warning severity received. 42 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 2.34 NetViewer Connection Map Under Conguration (534) Error ID: 534 MOC: OimNetviewerLink Version: n.a. Error information: <eventType> communicationsAlarm <probableCause> LinkFailure <specificProblems> NetViewer Connection Map Under Configuration <perceivedSeverity> warning <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: No action required. Wait until map reconfiguration is completed. Error description: A communication failure is detected due to a map reconfigura- tion. A50023-X4005-A2-4-7619 43 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 2.35 NetViewer Connection Down (535) Error ID: 535 MOC: OimNetviewerLink Version: n.a. Error information: <eventType> communicationsAlarm <probableCause> LinkFailure <specificProblems> NetViewer Connection Down <perceivedSeverity> critical <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: 1.) Check network connections of the OMP: Are the network cable plugs inserted correctly into the sockets at both ends? 2.) If the plugs are inserted correctly this alarmmeans that one lan card is faulted. Then contact your local staff providing the error message and exact information about your OMP. If the plugs aren't inserted correctly, plug them in. Note that for this version of RC the emitted alarm will not be cleared. Error description: The Netviewer is disconnected. 44 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 2.36 Local SMLC state le does not exist! (536) Error ID: 536 MOC: OimSmlc Version: n.a. Error information: <eventType> communicationsAlarm <probableCause> LinkFailure <specificProblems> Local SMLC state file does not ex- ist <perceivedSeverity> critical <thresholdInfo> (o) <monitoredAttributes> (o) <additionalText> (o) Immediate defense action: n.a. Proposed repair ac- tions: 1. Check Network connection between RC and SMLC server Are the cable plugs inserted correctly into the sockets at both ends? 2. Check the FTP script, which is responsible for the file trans- fer. Error description: The RC can not find/open the local SMLC state file. A50023-X4005-A2-4-7619 45 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 3 Notications 3.1 serviceResponse (RC_LOG) 3.2 serviceResponse (SbsOcm:session) Error ID: n.a. MOC: RC_LOG Version: n.a. Error information: <eventType> serviceReport <serviceReportCause> (m) serviceResponse <additionalText> (o) the following: <reason> SeeLogs on security event log in- stance delete log records <dateAndTime> (m) "DateAndTime" <userName> (m) "RC user login name" <hostName> (m) "Hostname of OMT" <sessionNumber> (m) "Number of OMT session" <terminalAddress> (m) "Display of OMT session" <affectedUser> (o) "The affected RC user login name" Immediate defense action: n.a. Proposed repair ac- tions: n.a. Error description: A security audit trail report as described in X.740 is given. Error ID: n.a. MOC: "SbsOcm":session Version: n.a. Error information: <eventType> serviceReport <serviceReportCause> (m) serviceResponse <additionalText> (o) the following: 46 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 3.3 serviceFailure (RC_LOG) <reason> (m)create User Profile delete User Profile set User Profile import Security Data export Security Data import Password Dictionary export Password Dictionary delete Password Dictionary abort User Session change Own Password change System Password abort Unix Session RC login RC logout reset Failed Login Counter set Global Settings lock Display unlock Display create Authorization Profile delete Authorization Profile set Authorization Profile create Subprofile delete Subprofile set Subprofile <dateAndTime> (m) "DateAndTime" <userName> (m) "RC user login name" <hostName> (m) "Hostname of OMT" <sessionNumber> (m) "Number of OMT session" <terminalAddress> (m) "Display of OMT session" <affectedUser> (o) "The affected RC user login name" Immediate defense action: n.a. Proposed repair ac- tions: n.a. Error description: A security audit trail report as described in X.740 is given. Error ID: n.a. MOC: RC_LOG Version: n.a. A50023-X4005-A2-4-7619 47 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 3.4 serviceFailure (SbsOcm:session) Error information: <eventType> serviceReport <serviceReportCause> (m) serviceFailure <additionalText> (o) the following: <reason> SeeLogs on security event log in- stance delete log records <dateAndTime> (m) "DateAndTime" <userName> (m) "RC user login name" <hostName> (m) "Hostname of OMT" <sessionNumber> (m) "Number of OMT session" <terminalAddress> (m) "Display of OMT session" <affectedUser> (o) "The affected RC user login name" Immediate defense action: n.a. Proposed repair ac- tions: n.a. Error description: A security audit trail report as described in X.740 is given. Error ID: n.a. MOC: "SbsOcm":session Version: n.a. Error information: <eventType> serviceReport <serviceReportCause> (m) serviceFailure <additionalText> (o) the following: <reason> (m) create User Profile delete User Profile set User Profile import Security Data export Security Data import Password Dictionary export Password Dictionary delete Password Dictionary abort User Session change Own Password 48 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 change System Password abort Unix Session RC login RC logout SeeLogs on security event log in- stance delete log records reset Failed Login Counter set Global Settings lock Display unlock Display create Authorization Profile delete Authorization Profile set Authorization Profile create Subprofile delete Subprofile set Subprofile <dateAndTime> (m) "DateAndTime" <userName> (m) "RC user login name" <hostName> (m) "Hostname of OMT" <sessionNumber> (m) "Number of OMT session" <terminalAddress> (m) "Display of OMT session" <affectedUser> (o) "The affected RC user login name" Immediate defense action: n.a. Proposed repair ac- tions: n.a. Error description: A security audit trail report as described in X.740 is given. A50023-X4005-A2-4-7619 49 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 3.5 unauthorizedAccessAttempt Error ID: n.a. MOC: "SbsOim":sbsOimAuthProfile Version: n.a. Error information: <eventType> securityServiceOrMechanismVio- lation <securityAlarmCause> (m) unauthorizedAccessAttempt <securityAlarmSeverity> (m) warning <securityAlarmDetector> (m) RC <serviceUser> (m) "RC user login name" <serviceProvider> (m) RC <additionalText> (o) the following: <reason> (m) unauthorized entered CLI command <dateAndTime> (m) "DateAndTime" <userName> (m) "RC user login name" <hostName> (m) "Hostname of OMT" <sessionNumber> (m) "Number of OMT session" <terminalAddress> (m) "Display of OMT session" Immediate defense action: n.a. Proposed repair ac- tions: n.a. Error description: A security service or mechanism violation as described in X.736 occurred. 50 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 3.6 sbsOimFileTransferControl Error ID: n.a. MOC: "SbsOim":sbsOimFileTransferControl Version: n.a. Error information: <eventType> "SbsOim":SbsUploadInfoType. It describes the event type (startUp- load, endUpload, endConversion) which notification is related to. <fileTransferId> The transfer identifier assigned by RC to each upload procedure. <fileName> The path name of the file uploaded. <result> The result of the upload (success, aborted, failed, none). Immediate defense action: n.a. Proposed repair ac- tions: n.a. Error description: This notification is used to inform the begin and the end of an upload regarding a file of measures. A50023-X4005-A2-4-7619 51 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 3.7 outOfHoursActivity Error ID: n.a. MOC: "SbsOim":sbsOimUserProfile Version: n.a. Error information: <eventType> timeDomainViolation <securityAlarmCause> (m) outOfHoursActivity <securityAlarmSeverity> (m) warning <securityAlarmDetector> (m) RC <serviceUser> (m) "RC user login name" <serviceProvider> (m) RC <additionalText> (o) the following: <reason> (m) command not in allowed time re- strictions <dateAndTime> (m) "DateAndTime" <userName> (m) "RC user login name" <hostName> (m) "Hostname of OMT" <sessionNumber> (m) "Number of OMT session" <terminalAddress> (m) "Display of OMT session" Immediate defense action: n.a. Proposed repair ac- tions: n.a. Error description: A security service or mechanism violation as described in X.736 occurred. 52 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 3.8 authenticationFailure Error ID: n.a. MOC: "SbsOcm":session Version: n.a. Error information: <eventType> securityServiceOrMechanismVio- lation <securityAlarmCause> (m) authenticationFailure <securityAlarmSeverity> (m) warning <securityAlarmDetector> (m) RC <serviceUser> (m) "RC user login name" <serviceProvider> (m) RC <additionalText> (o) the following: <reason> (m) RC login failed RC login failed: OMT unknown RC login failed: OMT has inappro- priate type RC login failed: OMT not unlocked RC login failed: Display host un- known RC login failed: Display host not unlocked RC login failed: Wrong password RC login failed: Password expired RC login failed: Out of allowed time period RC login failed: Invalid Unix user for RC operator RC login failed: RC operator ac- count blocked <dateAndTime> (m) "DateAndTime" <userName> (m) "RC user login name" <hostName> (m) "Hostname of OMT" <sessionNumber> (m) "Number of OMT session" <terminalAddress> (m) "Display of OMT session" Immediate defense action: n.a. Proposed repair ac- tions: n.a. Error description: A security service or mechanism violation as described in X.736 occurred. A50023-X4005-A2-4-7619 53 Outputs Radio Commander BR 7.0 / UMR 3.0 Output Manual OML:Non Standard Maintenance 4 Appendix 4.1 Specic Problems for the Alarm List Error ID Specic Problems 502 Disk Generic HW Error 503 Mirror/SubMirror Failure 504 MetaDb Failure 505 Threshold crossed 506 OMT-OMP communication failure (OMT) 507 Disconnected BSS 508 1 O-Link down 509 LAN Card Failure 510 Possible Fault on a HSI Communication Board 511 Possible Fault on a PCM Communication Board 512 PCM Switch failure 513 External Alarm Device Failure 515 Log instance reached minor threshold 516 Log instance reached major threshold 517 Log instance reached critical threshold 518 The agent has hit configured threshold level 519 The MPA has hit configured threshold level 520 B-link Corba disconnected 521 R-link CMISE disconnected 522 Sub Mirror Resyncing 523 Network unavailable 524 The nbManagedElementId received doesn't match the NodeB configura- tion within RC 525 SubMirror failure 528 OMP-OMP Communication failure (OMP) 529 NetViewer Server indeterminate notification 530 NetViewer Server critical notification 531 NetViewer Server major notification 532 NetViewer Server minor notification 535 NetViewer Connection Down Tab. 4.1 Specic Problems for the Alarm List in the GUI (without warnings) 54 A50023-X4005-A2-4-7619 Output Manual OML:Non Standard Maintenance Outputs Radio Commander BR 7.0 / UMR 3.0 536 Local SMLC state file does not exist! Error ID Specic Problems Tab. 4.1 Specic Problems for the Alarm List in the GUI (without warnings)