78%(9)78% fanden dieses Dokument nützlich (9 Abstimmungen)
4K Ansichten4 Seiten
This document summarizes the structural analysis and design criteria for a 2-storey residential building located in Bonifacio Extension, Aguada, Ozamis City. The criteria include design live loads, dead loads, material properties, seismic factors, and load combinations according to the 2010 National Structural Code of the Philippines. Reinforced concrete will be used with a minimum rebar diameter of 10mm and maximum of 16mm. Load combinations will follow the code specifications. The structural engineer, Engr. Joseph Cloyd L. Lamberte, signed off on the criteria.
This document summarizes the structural analysis and design criteria for a 2-storey residential building located in Bonifacio Extension, Aguada, Ozamis City. The criteria include design live loads, dead loads, material properties, seismic factors, and load combinations according to the 2010 National Structural Code of the Philippines. Reinforced concrete will be used with a minimum rebar diameter of 10mm and maximum of 16mm. Load combinations will follow the code specifications. The structural engineer, Engr. Joseph Cloyd L. Lamberte, signed off on the criteria.
This document summarizes the structural analysis and design criteria for a 2-storey residential building located in Bonifacio Extension, Aguada, Ozamis City. The criteria include design live loads, dead loads, material properties, seismic factors, and load combinations according to the 2010 National Structural Code of the Philippines. Reinforced concrete will be used with a minimum rebar diameter of 10mm and maximum of 16mm. Load combinations will follow the code specifications. The structural engineer, Engr. Joseph Cloyd L. Lamberte, signed off on the criteria.
LOCATION : BONIFACIO EXTENSION, AGUADA, OZAMIS CITY
STRUCTURAL ANALYSIS AND DESIGN CRITERIA DESIGN CRITERIA:
Live Load : Floor Load : 1920 Pa (Residential Occupancy) Table 205-1, NSCP2010 : 4800 Pa (Stair Loading) Dead Load : : 4000 N/m (Wall dead weight with opening) : 6500 N/m (Wall dead weight without opening) 2943 N/m 2 (Floor Dead weight plus floor finishes) Self weight : 23540 N/m 3 (Concrete) Fc : 20.7 MPa (3.0 ksi) Class A
Steel Modulus: 200GPa Fy : 276 MPa Main Reinforcements Grade 40 : 228 MPa Secondary Reinforcements Grade 33 Min. ReBar : 10 mm diameter Max ReBar : 16 mm diameter
Seismic Zone Factor, Z: 0.40 Section 208.4.4.1 of NSCP 2010
Importance Factor, I: 1.00 Standard Occupancy. Section 208.4.2 of NSCP 2010 Pension House Building
Rw : 8.5 Structural system numerical coefficient representative of the inherent over-strength and global ductility capacity for Concrete Moment Resisting Space Frame system.
Na : 1.0 Near source factor near Western Mindanao Fault Nv : 1.0 Near source factor near Western Mindanao Fault
Soil Type, S : 4.0 Soil Profile Silt Medium Dense/ Clay Med Stiff
Soil Bearing Cap: 100 kPa Maximum Soil Bearing Capacity, from table 7.7 See Soil Testing Result.
Max. EQ Mag: 7 & up Maximum Earthquake Magnitude consideration
Load Combination : As per Section 409.3 of the NSCP2010 6 th Edition 1.4 Dead Load (409-1)
1.2 Dead Load +1.6 Live Load +0.5 Roof Live Load (409-2)
1.2 Dead Load +1.0 Live Load +1.6 Roof Live Load (409-3)
1.508 Dead Load +1.4 Earthquake +Live Load (409-5)
1.208 Dead Load +1.4 Earthquake Load (409-7)
As per Section 426.409.2 of the NSCP2010 6 th Edition
1.358 Dead Load +1.275 Live Load +1.4 Earthquake (426-2)
SIGNED BY:
ENGR. JOSEPH CLOYD L. LAMBERTE, MSCE Structural / Civil Engineer Member: Philippines Institute of Civil Engineers Member: Structural Engineers Association of Davao PRC NO.: 0076882 PTR NO.: 2328937 A DATE : 01-11-13 TIN : 192-113-879