Beruflich Dokumente
Kultur Dokumente
0
0
S
L
A
N
T
I
N
G
D
I
S
C
C
H
E
C
K
V
A
L
V
E
S
T
h
e
S
t
a
n
d
a
r
d
o
f
E
x
c
e
l
l
e
n
c
e
C
H
E
C
K
V
A
L
V
E
S
B
U
L
L
E
T
I
N
31
VALVE & PRIMER CORPORATION
2 0 0 0
M i l l e n n i u m
E d i t i o n
1420 S. WRIGHT BLVD. SCHAUMBURG, IL 60193-4599
847.524.9000 FAX:847.524.9007 800.323.6969
website: www.apcovalves.com e-mail: factory@apcovalves.com
ISO FLANGE
CONNECTIONS AVAILABLE
Return to Previous Menu
32
SLANTING DISC CHECK VALVES . . . with over 35 years of experience to guarantee reliability and outstand-
ing performance. Ruggedly designed with minimal head loss and maximum anti-hammer characteristics.
The APCO SLANTING DISC CHECK VALVE because of its very unique two piece design and slant disc
position, has superior flow characteristics (lowest head loss) when compared to any hinged disc type check
valve available. Our two piece body design allows for a 40% expanded cross sectional flow area. So the area
occupied by the mass of the disc is more than compensated for by the expanded flow area.
Also the airfoil design of the disc, like the wing on a plane, offers minimal resistance to flow while lifting and
stabilizing in the full open position. Flow characteristics are further improved because the long laying length of
the valve body allows water to smoothly enter and pass through without turbulence, eddys or cavitation.
The slanting disc feature is not a gimmick. The slant disc position is a most important feature of this valve.
It offers minimum resistance to flow while minimizing water column reversal and slamming on shut down
due to the short distance the slant disc travels to shut-off position.
The off center pivot of the slant disc works to your advantage. The surface disc area above the pivot point
resists closing because it must close against the reversing water column. This counteracts the closing force
to the disc area below the pivot point. The result is no slam or minimal slam depending on column reversal
velocity.
The unbalanced weight (heavier below the pivot point) causes the slant disc to free fall into shut-off
position with minimal reverse flow. A slight pressure differential will cause the slant disc to open.
It has the lowest friction head loss of all conventional swing check valves. Due to this very low head loss
the APCO Slanting Disc is even suitable for heavy duty rotary air blower service. The APCO Slanting Disc
Check Valve pays for itself many times over in reduced power consumption and greater pumping efficiency
to the user. See the energy savings comparisons on the last page of this bulletin.
FIGURES SHOWN ARE BASED ON CERTIFIED FLOW TESTS CONDUCTED AT UTAH STATE UNIVERSITY, WATER RESEARCH
LABORATORY, REPORT NO. 299. VALVES SIZES 8 & 14. ACTUAL FIELD CONDITIONS MAY VARY FROM THESE CURVES.
NOTE: WHEN COMPARING SIMILAR COMPETITORS PUBLISHED DATA, ONLY USE CERTIFIED FLOW TEST DATA.
CERTIFIED FLOW TESTS CONDUCTED AT UTAH STATE UNIVERSITY
WATER RESEARCH LABORATORY, LOGAN, UTAH, 1991.
2 3 4 6 8 10 121416182024 30 36 42485460 72
2 3 4 5 6 7 8 9 2 3 4 5 6 7 8 9 2 3 4 5 6 7 8 9 2 3 4 5 6 7 8 9 2 3 4 5 6 7 8 9
10
9
8
7
6
5
.9
.8
.7
.6
.5
4
3
.4
.3
2
1
.2
.1
10
100 1,000 10,000 100,000 1,000,000
ACTUAL FLOW TEST FOR HEAD LOSS CHARACTERISTICS
FLOW IN GALLONS PER MINUTE
H
E
A
D
L
O
S
S
I
N
F
E
E
T
3 4 6 8 10 12 14 16 18 20 24 30 36 42 48 54 60 72
802 803 804 806 808 810 812 814 816 818 820 824 830 836 842 848 854 860 872
9
1
2 9
1
2 11
1
2 15 19
1
2 24
1
2 24 30 30 33 32 38 52 59
1
2 62
1
2 65 78 87 106
6 7
1
2 9 11 13
1
2 16 19 21 23
1
2 25 27
1
2 32 38
3
4 46 53 59
1
2 66
1
4 73 86
1
2
2 3 4 6 8 10 12 14 16 18 20 24 30 36 42 48 54 60 72
7
3
8 8
1
2 9
3
4 13
3
4 15
1
2 18 21 25 28 30 31
1
2 36
1
2 46
1
2 51 58 67
1
2 71 84 102
5
8
3
4
15
16 1 1
1
8 1
3
16 1
1
4 1
3
8 1
7
16 1
9
16 1
11
16 1
7
8 2
1
8 2
3
8 2
5
8 2
3
4 3 3
1
8 3
1
2
8
1
2 9 11 17
1
2 22 25
1
2 27 33 36 38 41 48 57 62
1
2 63 72 77 90 125
4 4 8 8 8 12 12 12 16 16 20 20 28 32 36 44 44 52 60
3
4
3
4
3
4
7
8
7
8 1 1 1
1
8 1
1
8 1
1
4 1
1
4 1
3
8 1
3
8 1
5
8 1
5
8 1
5
8 2 2 2
4
3
4 6 7
1
2 9
1
2 11
3
4 14
1
4 17 18
3
4 21
1
4 22
3
4 25 29
1
2 36 42
3
4 49
1
2 56 62
3
4 69
1
4 82
1
2
50 55 82 164 265 510 650 1044 1050 1535 1685 2650 5850 7600 9000 14000 16000 28241 44000
9
1
2 12
1
2 11
1
2 15 19
1
2 24
1
2 24 30 30 33 32 38 52 59
1
2 62
1
2 65 78 87 106
6
1
2 8
1
4 10 12
1
2 15 17
1
2 20
1
2 23 25
1
2 28 30
1
2 36 43 50 57 65 * * *
2 3 4 6 8 10 12 14 16 18 20 24 30 36 42 48 54 60 72
7
3
8 8
1
2 9
3
4 13
1
4 15
1
2 18 21 25 28 30 31
1
2 36
1
2 46
1
2 51 58 67
1
2 71 84 102
7
8 1
1
8 1
1
4 1
7
16 1
5
8 1
7
8 2 2
1
8 2
1
4 2
3
8 2
1
2 2
3
4 3 3
3
8 3
11
16 4 * * *
8
1
2 9 11 17
1
2 22 25
1
2 27 33 36 38 41 48 57 62
1
2 63 72 77 90 125
8 8 8 12 12 16 16 20 20 24 24 24 28 32 36 40 * * *
3
4
7
8
7
8
7
8 1 1
1
8 1
1
4 1
1
4 1
3
8 1
3
8 1
3
8 1
5
8 2 2
1
4 2
1
4 2
1
4 * * *
5 5
5
8 7
7
8 10
5
8 13 15
1
4 17
3
4 20
1
4 22
1
2 24
3
4 27 32 39
1
4 46 52
3
4 60
3
4 * * *
55 65 93 199 357 573 693 1179 1600 1890 2100 3300 6800 8300 10500 18000 21000 34000 55000
2
5
0
L
B
.
F
L
A
N
G
E
1
2
5
L
B
.
F
L
A
N
G
E
S E R I E S 8 0 0
150# AND 300# CLASS DIMENSIONS SAME AS ABOVE
EXCEPT 12 A = 27
1
2 HIGHER PRESSURE CLASS PAGE 36.
A
P
C
O
S
L
A
N
T
I
N
G
D
I
S
C
C
H
E
C
K
V
A
L
V
E
2
4
C
O
N
V
E
N
T
IO
N
A
L
S
W
I
N
G
C
H
E
C
K
V
A
L
V
E
100
90
80
70
60
50
40
30
20
10
0 10 20 30 40 50 60 70 80 90 100
55 51 47 43 39 35 31 27 23 19 15
% OF VALVE DISC OPENING
F
L
O
W
%
O
F
F
U
L
L
O
P
E
N
I
N
G
DEGREES OF DISC POSITIONING
GPM x HL x Sp. Gr. x .746 x Cost x 24 Hour x 365 Days
3960 x Ec
VALVE & PRIMER CORPORATION HEREBY RESERVES THE RIGHT TO CHANGE ANY
COMPONENT PARTS WHICH, IN THE OPINION OF ITS ENGINEERING DEPARTMENT,
WILL IMPROVE THE PRODUCT OR INCREASE ITS SERVICEABILITY.
DIMENSIONS ARE FOR ILLUSTRATIVE PURPOSES ONLY. PLEASE CONFIRM ALL DIMENSIONAL
INFORMATION WITH VALVE & PRIMER CORPORATION ENGINEERING DEPARTMENT.
Return to Previous Menu