0 Bewertungen0% fanden dieses Dokument nützlich (0 Abstimmungen)
129 Ansichten12 Seiten
BENSHAW ADVANCED CONTROLS and DRIVES Programmable, Intelligent, High Performance Solutions for any Motor Control Application. MX Series! Standard I / O: digital Metering: Enhanced Motor Protection: More Flexibility: Configurable analog Output: Configurable digital Input: Multiple Starting Ramps: User Interface: 4 digital inputs, 1 analog output, 3 Form C relay outputs Average Current, L1 Current, L2 Current, L3 Current, Current Imbalance %
BENSHAW ADVANCED CONTROLS and DRIVES Programmable, Intelligent, High Performance Solutions for any Motor Control Application. MX Series! Standard I / O: digital Metering: Enhanced Motor Protection: More Flexibility: Configurable analog Output: Configurable digital Input: Multiple Starting Ramps: User Interface: 4 digital inputs, 1 analog output, 3 Form C relay outputs Average Current, L1 Current, L2 Current, L3 Current, Current Imbalance %
BENSHAW ADVANCED CONTROLS and DRIVES Programmable, Intelligent, High Performance Solutions for any Motor Control Application. MX Series! Standard I / O: digital Metering: Enhanced Motor Protection: More Flexibility: Configurable analog Output: Configurable digital Input: Multiple Starting Ramps: User Interface: 4 digital inputs, 1 analog output, 3 Form C relay outputs Average Current, L1 Current, L2 Current, L3 Current, Current Imbalance %
Programmable, Intelligent, High Performance Solutions for any Motor Control Application Reduced Voltage Starting Pump Control Generator Starting Reversing Two Speed Braking Synchronous Wound Rotor RediStart - Low Voltage Slid State Starters 200 to 600V, 1 to 2500HP RediStart - Low Voltage Solid State Starters 200 to 600Volts, 1 to 2500HP TM Choose Your Level of Control... Programmable... MX Series ! Standard I/O: Digital Metering: Enhanced Motor Protection: More Flexibility: Standard Communication Port: Configurable Analog Output: Configurable Analog Input: Configurable Digital Input: Multiple Starting Ramps: User Interface: 4 digital inputs, 1 analog output, 3 Form C relay outputs Average Current, L1 Current, L2 Current, L3 Current, Current Imbalance %, Ground Fault Amps, Average Volts, L1-L2 Volts, L2-L3 Volts, L3-L1 Volts, Overload %, Power Factor, Watts, VA, kW Hours, MW Hours, Phase Order, Line Frequency, Analog Input Value, Analog Output Value, Run Time-Days, Run Time- Hours, # of Starts, Tru Torque %, Power % Motor Thermal OL, Independent Starting and Running OL, Up to Speed Protection, Low Line Voltage, High Line Voltage, Low Line Frequency, High Line Frequency, Phase Reversal, Phase Loss, Instantaneous Over Current, Over Current, Under Current, Current Imbalance, Ground Fault Over 70 Configurable Features ModBUS built-in and others via option boards. 4-20mA signal Configurable to: current, kW, 0-100%V, OL% phase controller, low trip limit, high trip limit Local/Remote, Auto/Manual, Serial Link, 2-wire/3-wire, Dual Ramps All with initial and maximum settings, programmable ramp times and adjustable kick current Open loop for standard applications for pumping applications to reduce pressure surges for limited power applications i.e. generators or weak systems 4 Digit, 7 Segment board mounted LED Interface 2 Line, 16 characters per line Liquid Crystal Display ! ! ! ! ! ! ! ! ! Voltage Ramp - Current Ramp - Torque Ramp - Power Ramp - Standard: Optional: OPTIONAL LCD KEYPAD KIT PART#MX-2M-RKP-00 Only Benshaw has a three year guarantee. the Benshaw Promise. Every Benshaw Solid State Starter is guaranteed for Other manufacturers limit their warranties to just one year. At Benshaw, we believe that because we build them better, we guarantee them longer. We call that three full years. U L LISTED US C QUICK START MENU All of Benshaws low voltage power stacks can be integrated with two levels of control - the MX Series or the Micro II Series. The MX Series Control provides the user with a powerful group of programming parameters designed for flexibility in industrial applications. MX controls provide simple setup and commissioning via the quick start menu and include the following functions: Group Description Setting Range QST 00 Jump to parameter 1-9 QST 01 Motor FLA 1 6400 QST 02 Motor Service Factor 1.001.99 QST 03 Motor Overload Class Running Off, 140 QST 04 Local Source QST 05 Remote Source Keypad Terminal Serial QST 06 Initial Motor Current 50600 QST 07 Maximum Motor Current 100800 QST 08 Ramp Time 0300 QST 09 UTS Time / Transition Time 1900 MX Single Board Controller 120V Control Relay Outputs Digital Inputs Modbus Serial Port Reset Pushbutton CT Switch LED Keypad Analog Output Analog Input Quick Connect SCR Terminals Micro II Series The Micro II Series multiboard design is modular and can be configured to solve any motor control application, including: Jogging Reversing Synchronous Power Outage Ride Thru DC Injection Braking Wound Rotor Two Speed Two Winding Two Speed Single Winding ...Intelligent, Motor Control & Protection MX vs Micro II Comparison Function MX Control MII Control Function MX Control MII Control CONTROL FUNCTIONS YES YES METERING Current Ramp YES YES Current-Average YES YES Torque Ramp YES YES Current-Phase-Phase YES YES KW Ramp YES YES Voltage-Average YES YES Voltage Ramp YES YES Voltage-Phase-Phase YES YES Max Current YES YES % Current Imbalance YES YES Initial Current YES YES Power Factor YES YES Up to Speed Timer YES YES Watts YES YES Kick Start YES YES VA YES YES Kick Time YES YES KW Hours YES YES Decel YES YES MW Hours YES YES Tachometer Ramp NO OPTION Phase Order YES YES Line Frequency YES YES I/O FUNCTIONS Ground Fault Current YES YES 2 Wire Start/Stop YES YES Overload % YES YES 3 Wire Start/Stop YES YES Power % YES YES Network Start/Stop YES YES Tru Torque % YES YES Keypad Start/Stop OPTION YES User Run Time YES YES Local/Remote Digital Input YES NO # of Starts YES YES Dual Ramps YES YES User Elapsed Time Meter Resettable YES YES External Fault Input YES YES Elapsed Time Meter Non- Resettable NO YES DC Space Heater Function YES YES RTD Temperature NO OPTION Up to Speed Output YES YES Real Time Clock NO YES Fault Output YES YES Running Output YES YES I/O Alarm Output YES YES Standard Digital Inputs 4 9 Ready Output YES YES Standard Relay Outputs 3 3 OL Alarm Output YES YES Optional Relay Outputs NO 4 OR 7 Shunt Trip Output YES YES Analog Input YES NO Undercurrent Output YES YES Analog Output YES OPTION Over Current Output YES YES Ground Fault YES YES MOTOR PROTECTION Running Output YES YES Running OL YES YES Starting OL YES YES SPECIAL FUNCTIONS Phase Loss YES YES Reversing YES YES Phase Reversal YES YES Wound Rotors YES YES Low or High Frequency fault YES YES Voltage Follower YES NO Low Line Voltage YES YES Motor Space Heater YES YES Overcurrent YES YES Energy Saver YES YES Undercurrent YES YES Jogging NO YES Current Imbalance YES YES Reverse Jogging NO YES Ground Fault YES YES DC Injection Braking Light Duty NO YES Shorted SCR YES YES DC Injection Braking Heavy Duty NO OPTION UTS Timer Exceeded YES YES Synchronous Motor Control NO OPTION Record previous ten faults YES YES Power Outage Ride Thru NO YES W/UPS Time Date Stamp last 99 Events NO YES 8 Channel RTD Protection NO OPTION COMMUNICATIONS Time Between Starts NO YES Modbus YES OPTION Starts Per Hour NO YES Devicenet NO YES Backspin Timer NO YES R485 YES OPTION Micro II Modular Multi Board Controller Choose Your Power Section... Integral Bypass... RB Series Integral Bypass Power Stack The RB Series integrated bypass power stack is a rugged, heavy duty, solid state starter assembly. The modular design includes separate power poles for each phase for ease of maintenance. Each power pole is designed with an integral bypass contactor for a compact, efficient profile. All of Benshaws power stacks are available with MX or Micro II control and are guaranteed for three years... standard! RBX Power Pole - 150A RBX-1-S-240A-15C Stack Ratings: Service Factor: Standard Duty: 350% for 30 secs Heavy Duty: 500% for 30 secs Severe Duty: 600% for 30 secs Standard Duty: 115% continuous Heavy Duty: 125% continuous Severe Duty: 125% continuous RBX-1-S-838A-20C Integral Bypass Contactor Stack Over Temperature Protection NEMA 2 Hole Pattern Bottom Entry/ Bottom Exit 1600 PIV SCRs In Reverse Parallel Configuration DI/DT Protection NEMA 2 Hole Pattern Top Entry/ Top Exit ULService & - Designed for Emergency Full Voltage Starting - Panel Mounted Selector Switch RVSS-OFF-ATL - NEMA or IEC Rated Contator - Separate Electronic OL Relay for ATL Protection - Phase Reversal - Class 1-30 Selectable - Phase Loss - Current Imbalance - Adjustable OL Setting - Jogging Applications - Energy Saver Applications - High Duty Cycle Starting - Long Starting Times - High Inertia Starting - 1.25 S.F. Select MX or Micro II Controls to Match Your Application RBX Series Solid State Starters Selection Information Standard Duty MODEL NUMBER HORSEPOWER RATING STANDARD DUTY = 350% CURRENT FOR 30 SECS DIMENSIONS (INCHES) 208V 230V 460V 600V H x W x D RBX-1-S-027A-11C 7.5 10 20 25 14.0 x 10.0 x 6.9 RBX-1-S-040A-11C 10 15 30 40 14.0 x 10.0 x 6.9 RBX-1-S-052A-12C 15 20 40 50 14.0 x 10.0 x 6.9 RBX-1-S-065A-12C 20 25 50 60 14.0 x 10.0 x 6.9 RBX-1-S-077A-13C 25 30 60 75 15.0 x 10.0 x 7.7 RBX-1-S-096A-13C 30 40 75 100 15.0 x 10.0 x 7.7 RBX-1-S-125A-14C 40 50 100 125 21.6 x 12.3 x 8.9 RBX-1-S-156A-14C 50 60 125 150 21.6 x 12.3 x 8.9 RBX-1-S-180A-14C 60 75 150 200 21.6 x12.3 x 8.9 RBX-1-S-240A-15C 75 100 200 250 22.0 x 12.3 x 9.2 RBX-1-S-302A-15C 100 125 250 300 22.0 x 12.3 x 9.2 RBX-1-S-361A-16C 125 150 300 400 23.9 x 12.9 x 9.2 RBX-1-S-414A-17C 150 - 350 - 28.3 x 18.5 x 11.3 RBX-1-S-477A-17C - 200 400 500 28.3 x 18.5 x 11.3 RBX-1-S-515A-17C 200 - 450 - 28.3 x 18.5 x 11.3 RBX-1-S-590A-18C - 250 500 600 28.3 x 18.5 x 11.3 RBX-1-S-720A-19C 250 300 600 700 28.3 x 18.5 x 11.3 RBX-1-S-838A-20C 300 350 700 800 29.3 x 18.5 x 11.3 Heavy Duty MODEL NUMBER HORSEPOWER RATING HEAVY DUTY = 500% CURRENT FOR 30 SECS DIMENSIONS (INCHES) 208V 230V 460V 600V H x W x D RBX-1-S-027A-11C 7.5 10 20 25 14.0 x 10.0 x 6.9 RBX-1-S-040A-11C 10 15 30 40 14.0 x 10.0 x 6.9 RBX-1-S-052A-12C 15 20 40 50 14.0 x 10.0 x 6.9 RBX-1-S-096A-13C 30 40 75 100 15.0 x 10.0 x 7.7 RBX-1-S-125A-14C 40 50 100 125 21.6 x 12.3 x 8.9 RBX-1-S-180A-15C 60 75 150 200 22.0 x 12.3 x 9.2 RBX-1-S-361A-16C 75 100 200 250 23.9 x 12.9 x 9.2 RBX-1-S-414A-17C 125 150 300 400 28.3 x 18.5 x 11.3 RBX-1-S-590A-18C 200 200 450 500 28.3 x 18.5 x 11.3 RBX-1-S-720A-19C - 250 500 600 28.3 x 18.5 x 11.3 Severe Duty MODEL NUMBER HORSEPOWER RATING HEAVY DUTY = 600% CURRENT FOR 30 SECS DIMENSIONS (INCHES) 208V 230V 460V 600V H x W x D RBX-1-S-027A-11C 5 7.5 15 20 14.0 x 10.0 x 6.9 RBX-1-S-040A-11C 10 10 30 40 14.0 x 10.0 x 6.9 RBX-1-S-052A-12C - 15 - - 14.0 x 10.0 x 6.9 RBX-1-S-096A-13C 25 30 60 75 15.0 x 10.0 x 7.7 RBX-1-S-125A-14C 30 40 75 100 21.6 x 12.3 x 8.9 RBX-1-S-180A-15C 50 60 125 150 22.0 x 12.3 x 9.2 RBX-1-S-361A-16C 60 75 150 200 23.9 x 12.9 x 9.2 RBX-1-S-414A-17C 100 125 250 300 28.3 x 18.5 x 11.3 RBX-1-S-590A-18C 150 200 450 500 28.3 x 18.5 x 11.3 RB3 Dual Redundant Stack RC Continuous Rated Stack Benshaws RB3 Series utilize a separate bypass contactor for the most flexibility in your application. The panel mounted selector switch offers the user the option of selecting Soft Start or Across the Line Mode. Benshaws RC Series Solid State Starter is a rugged, non-bypassed unit. It is an economical solution at low horsepower. In addition, the fan cooled stack provides high duty cycle and high inertia starting and energy saver operation. * For Micro II Control - Substitute M for X in the model number (Increases depth by 1) RSE II Starters provide solid state reduced voltage starting for normal operation and full voltage emergency back- up starting with complete electronic motor protection at the flip of a switch. This unique design is the ideal solution for critical applications where downtime is extremely disruptive to production operations and can not be tolerated. Benshaws Micro II solid state controls provide precise digital starting and stopping, motor protection, metering, diagnostics and communications...standard. Dual Redundant Product Highlight - RSE Series Starter II NEMA12, Combination, Dual Redundant Solid State Starter Solid State Reduced Voltage Starting - Normal Operations Switch Selectable Emergency Backup Full Voltage Starter 500% - 30 seconds, 125% Continuous Duty Rated UL Listed, 1800 PIV Rated SCRs Auto Switch Dual Redundant Electronic Motor Protection Micro II - TruTorque Solid State Control System Embedded Digital Metering, Power Quality Protection & Diagnostics TM Benshaw RSE Series Starters are supplied to the following specifications II standard: 1. N 12, Dual redundant, Combination/Circuit Breaker 2. 500% - 30 seconds rated solid state starter - UL certified & listed 3. 1800 PIV rated SCRs -UL Certified & Listed 4. 125% continuous duty rated solid state starter - UL certified and listed 5. Selector switch for selecting solid state or full voltage operation mounted inside enclosure 6. Full HP rated bypass contactor with a 1.15 service factor, wired for normal bypass operation and full voltage start and run operation, with normally open auxiliary contact. 7. Separately mounted SPE Series overload relay wired for full voltage starting and run operation. The SPE Series overload has the following standard features: Class 1-30, adjustable 1 NO/1 NC trip contact Trip free design Phase imbalance protection Phase reversal protection Phase loss detection Test Function/trip indication Fault Indication 8. 110 Volt control power transformer with primary and secondary fuses 9. Door mounted start and stop pushbuttons 10. Door mounted key pad 11. Door mounted run indicating light 12. Door mounted local-off remote switch 13. Door mounted overload reset 14. Terminal strip mounted inside enclosure for remote start - stop connection 15. Auxiliary relay with (2) form C run contacts 16. Benshaw Micro II, Programmable Motor Controller with complete soft start, soft stop and motor protection capabilities (see details on next page) 17. Devicenet Communications RSE Operator Controls II ULService Entrance Rated & Labeled RSE Dual Redundant Severe Duty Starter II Full Voltage Emergency Back-Up Switch Solid State Reduced Voltage Starting & Stopping U L LISTED US C Customer Solutions... Standard Stock Packages Built to Your Specifications Typical Customer Solutions Control modifications whatever you specify Combination starters to meet your system requirements Power Stacks to fit your application Enclosures to match your environment Communication Modules to match your network RS232/485 Modbus DeviceNet Custom Interfaces Over 250 modifications and accessories are available, including: pilot devices, PLCs, control power transformers switches, meters, relays, space heaters and protective devices. 15 to 2000 amp circuit breaker 40 to 2000 amp non-fused disconnect 30 to 800 amp fusible disconnect Flange or rotary handle mechanism Integral Bypass Dual Redundant Continuous Rated Standard, Heavy & Severe Rated Standard designs - NEMA1,12, 4, chassis OEM/unit mount, custom designs as specified Special enclosures - 3R, 4X, 7, 9, as specified ABS/DNV approved for marine duty Motor Control Centers Customer specific control logic Severe Duty Soft Starter Benshaw has developed engineering, drafting, materials management and Quality Systems focused on designing and building customer solutions. This capability combined with an extensive inventory of control components, protective relays, circuit breakers, contactors, enclosures and other electrical/electronic devices provides our customers with the quickest shipment of engineered products in the industry. Advanced Build to Order Synchronous Motor Starter Engineered Products General Purpose, Pump Control, Generator Starting General Purpose Varying Load Conditions Generator Control Pump Control Ramp Profile 1 Ramp Profile 2 Initial Current 2 Kick Level Maximum Current 2 Initial Current Maximum Current Kick Time Ramp Time 2 Ramp Time Kick Level 2 Kick Time 2 Current Time Kick Time Ramp Time Up To Speed Timer Initial Current Kick Current Max Current Start command Motor FLA Motor Input Power Time Kick Time Ramp Time Up To Speed Timer Running Power Initial Power Kick Current Max Power Start command Designed for Pump Control Applications Reduces harmful torque/pressure surges Protects against water hammer Torque control in Start & Stop Modes Provides initial torque, max torque, and ramp time Simple Setup Provides Initial Current, Max Current and Ramp Time Settings Limits inrush current and mechanical stress Dual Ramps Current Ramp Tru Torque Ramp KW Ramp TRUTORQUE vs TM PUMP DECEL WITH VOLTAGE CONTROL Torque Spikes & Water Hammer without TruTorque TruTorque Controlled Decel Voltage Controlled Decel Designed for Generator or soft source applications Minimizes power consumption during start Provides initial power, max power and ramp time settings For any Application Reversing, Braking, Two Speed, Synchronous, Wound Rotor RSM7 RSM10 RSM10/12TS: RSM11 SMRSM6 WRSM6 ! ! Micro II Control with 7 SCRs for integrated/programmable DC-injection braking. Standard or heavy duty braking torque ! ! Micro II Control with 10 SCRs for integrated/programmable reversing operation Programmable soft start/stop with forward/reverse capability ! ! Micro II Control with additional SCRs for programmable two speed operation Single winding or two winding motors ! Micro II Control with 11 SCRs for integrated programmable DC injection braking and reversing capability ! ! Micro II Control with integrated/programmable synchronous excitation controls Automatic power factor control ! ! Micro II Control with integrated/programmable wound rotor controls High Torque starting or speed control Non-reversing DC Brake Reversing Reversing DC Brake Synchronous Non-reversing Two-speed Wound Rotor Integrated Motor and Load Protection Programmable Motor Protection, Diagnostics... Real-Time I T Thermal Modeling 2 Percent Voltage Unbalance NEMA MG1 Motor Thermal Effect N o r m a l P o w e r / Q u a l i t y V o l t a g e , C u r r e n t , P h a s e Normal Run 1) PORT Subcycle Detection Power/Quality Outage 4) PORT Subcycle Detection Power/Quality Return PORT - Power Outage Ride Through TM Normal Run Transient Power Outage Normal Run Micro II - I T Thermal Memory 2 Micro II - I T 36 Samples per Cycle 2 Control Circuit UPS Normal Run 3) Power Loss Coast Stop 5) TruTorque Spinning Soft Restart 6) PORT Time Out 2) PORT Controlled Shutdown/Recovery Sequence Power System Recovery Power System Outage Time Programmable Motor/Load Fault Protection Permissive Inputs ! ! ! ! ! ! ! ! ! ! ! Electronic OL % Current Imbalance Over Current Under Current Phase Reversal Phase Loss Machine Ground Fault Shorted SCR UTS Time Limit Exceeded High Frequency Low Frequency ! ! ! ! ! Number of Auto Resets Number of Starts per Hour* Time Between Starts* Back Spin Timer* Zero Speed Timer* * Micro II Series Only MX and Micro II Controls provided comprehensive motor/process protection. Their integrated voltage and current sensing, high speed sampling rates (36 I T samples per cycle) and advanced algorithms provide unequaled protection for motors, machines and critical processes. Users can select the specific class (1 to 40) overload curve desired and over 25 other protective functions to match the unique requirements of their application. An overview of these precision protective functions is outlined below: 2 Overload Curves *Programmable RTD Module Digital Metering & Communications MX LCD Keypad Micro II - 99 Event Recorder w/Time Date Stamp MX and Micro II controls calculate, analyze and present monitoring and diagnostics data in plain english displays to ensure operating personnel have Real-Time visibility of the motor, load and power system. Embedded digital meters, programmable alarms, outputs, revolving events and communications are presented to the operator via the LCD keypad or RediView Windows interface. Data is displayed in straight forward messages that provide complete visualization of the Real-Time status and prior events for supporting operating and maintenance personnel requirements. An overview of the Real-Time data functions is summarized below: RediView MX Monitoring Screen Starter Communication Setup Screen On Line and Off Line Programming Print/Save/Document Parameters E-Mail Parameters RediView Micro II Monitoring Screen DIGITAL METERING Currrent - Average Current - Phase - Phase Voltage - Average Voltage - Phase - Phase % Current Imbalance Power Factor Watts VA KW hours MW hours Phase Order Line Frequency Ground Fault Current Overload % Power % Tru Torque % User Run Time # of Starts User Elapsed Time Meter - Resettable Elapsed Time Meter - Non Resettable)* RTD Temperatures* Smart Maintenance Data & Displays Plain English LCD Display...and Real Time Windows Interface Sales & Service The widest range of motor controls and drives available anywhere... 7x24 customer service... Benshaws customer service organization is dedicated to providing comprehensive 7-day-a-week, 24-hour- a-day phone support, repairs, spare parts, field engineering, retrofits and training services...when and where you need us. Whether its Benshaw or third-party equipment, you can count on our experi- enced team, backed by the latest diagnostics and repair tools and a two million dollar parts inventory to support your operations. ................. Repairs are made on Benshaw and third-party equipment by trained, exper- ienced personnel, using the latest diagnostic and test equipment to repair: Printed circuit boards. Power electronic control assemblies. Electrical control assemblies. Field Services are performed on-site by skilled technicians, engineers or complete teams, if needed, including: Start-up commissioning. Field repairs. Field analysis/data collection. Preventative maintenance. Training is provided in both a classroom and a hands-on environment that provides the student with practical skills, including: Basic electrical maintenance. Electronic maintenance and diagnostics. Benshaw product courses. Customized systems courses (maintenance- or operations-based). Benshaw Express is a new worldwide program that guarantees a two-hour emergency response on a variety of starters, drives and parts from our dedicated warehouse at the airport. It includes: 7x24 Same day shipment. Either air or truck delivery. Airport pick-up or door- to-door service. 7x24 Hotline Support from our operations in Pittsburgh, Listowel (Canada), Detroit and Phoenix, including: Technical phone support. Overnight parts shipment. 24-hour service dispatch. Coordination of all service capabilities. Solid state starters fractional up to 60,000 HP at 15kV AC drives to 1000 HP Electromechanical controls to 800 amps BENSHAW United States Canada South America Shanghai Australia Singapore BENSHAW, Inc. BENSHAW West BENSHAW Canada Pittsburgh, Pennsylvania Dayton, Ohio Syracuse, New York Boston, Massachusetts Wilmington, Delaware Charlotte, North Carolina Jacksonville, Florida Birmingham, Alabama Los Angeles, California San Francisco, California Detroit, Michigan LaCrosse, Wisconsin Chicago, Illinois Kansas City, Missouri Phoenix, Arizona Seattle, Washington Denver, Colorado Houston, Texas Minneapolis, Minnesota Newark, New Jersey Listowel, Ontario Toronto, Ontario Montreal, Quebec Calgary, Alberta Sao Paulo, Brazil Santiago, Chile Lima, Peru Bogota, Colombia 1659 E. Sutter Road Glenshaw, PA15116 Phone: (412)487-8235 Fax: (412)487-4201 7820 East Evans Drive Suite 900 Scottsdale, AZ 85260 Phone: (480)905-0601 Fax: (480)905-0757 550 Bright St. E. Listowel, Ontario N4W 3W3 Phone: (519)291-5112 Fax: (519)291-2595 Visit or E-mail Benshaw on the worldwide web at www.benshaw.com, benshawexpress.com, or contact: BCAM-04-013-00