Liderazgo en Calidad
Compromiso constante de calidad :
Fabricacin y automatizacin integrados.
Calidad en produccin automatizada.
Capacitacin, certificado y garanta
Normas de Calidad ISO 9001:2000 y 14001
ISO 9001:2000. Especificaciones tcnicas de
gestion de la calidad
ISO 14001 norma gestin ambiental
Cumple con Normas Internacionales Cumple con Normas Internacionales
NOM CENELEC
EN xxx
EIA/TIA
ANSI
BSI JIS CSA
ISO-IEC 11801
Referencias de las Normas TIA e ISO
10 Gbps
40 Gbps
1 Gbps
Qu es un SCE Sistema de Cabledo
Estructurado?
1. Sistema de transporte de informacin
con base en normas.
2. Normas de ingeniera, instalacin y
administracin.
3. Formado por componentes de cobre o
fibra para comunicaciones en una red.
4. Conocido como:
- Sistema de Cableado de
Telecomunicaciones. Telecomunicaciones.
- Sistema de Cableado Genrico, PDS
(Premise Distribution System), o
- Simplemente Cableado
Estructura de un SCE
Backbone de
Campus
(Interedificios)
Subsistema
Horizontal
Backbone de
Edificio
(Intraedificio)
Enlace Permanente
Cable Horizontal
Longitud < 90 m
Cable Horizontal
Longitud < 90 m
HC HC
Salida de
Telecomunicaciones
(TO)
Salida de
Telecomunicaciones
(TO)
Esquema Tpico Horizontal
Equipo de Red
90 m
(rec > 15 m)
90 m
(rec > 15 m)
5 m 5 m
5 m 5 m
Equipo de Red
a + b 5 m a + b 5 m
Canal 100 m Canal 100 m
rea de Trabajo (WA)
Cordones Cordones
TO

MuTOA
TO

MuTOA
Cordones Cordones
Usuarios Actuales de tecnologa
Aplicaciones ERP/CRM
Manufacturas: reportes
VoD, Video/voz sobre IP,
CCTV/Seguridad
Teleconferencia
Escuela a la distancia
Gobierno
Teleradiologa Telemedicina.
Transmisin de informacin y medicina
Simulacin en tiempo real
Llamadas de emergencia (911) con
integracin de sistemas de informacin
geogrfica (GIS)
Puerto uplink para backbone para
comunicaciones de switch a switch
rea de cuidados con la salud
Instituciones financieras.
Telepresencia (audio y video)
especializada principalmente en reas
geogrficas distantes
Telepresencia (audio y video)
Vdeo de alta calidad encriptada.
Las aplicaciones actuales
requieren > 500 Mhz
Longevidad de las Categoras
Cat 5e 100 Mhz
Cat 6 250 Mhz
Cat 7 600 Mhz
Cat 6 A UTP 500 Mhz
Cat 7 A 1000 Mhz
Cat 6 A F/UTP 500 Mhz
Ethernet 10 y 100 Mbps
Ethernet 1000 Mbps = 1Gbps
10Gbps
10
1990
1998 2002 2006 2010 2014 2018
Cat 3 16 Mhz
Cat 5e 100 Mhz
Ethernet 10 Mbps
Ethernet 10 y 100 Mbps
CCTV trabaja en 868 MHZ
Especificaciones Cat 6A
10BASE 10BASE- -T T
4 Mb/s Token Ring 4 Mb/s Token Ring
16 Mb/s Token Ring 16 Mb/s Token Ring
100Base 100Base- -T T
155 Mb/s ATM 155 Mb/s ATM
1000BASE 1000BASE- -T T
1000BASE 1000BASE- -TX TX
10GBASE 10GBASE- -T T
Categora 6A 500 MHz
10GBASE 10GBASE- -T T
SIEMON ofrece toda la gama de soluciones en CAT 5e, CAT 6, CAT 6 A en
UTP, CAT 6A en F/UTP, CAT 7 S/FTP, CAT 7 A S/FTP y Fibra ptica
Referencias de las Normas TIA e ISO
Cat 6A : F/UTP
Par Trenzado
Apantallado
ScTP, FTP, F/UTP
Cat 7A : S/FTP
Par Trenzado
Blindado
Apantallado
Cat 5e : UTP
Par Trenzado
No blindado
Cat 6 : UTP
Par Trenzado
No blindado
ScTP, FTP, F/UTP
Placing Thermo-couplers
Factores Clave
Disipacin del Calor:
- F/UTP de Cat 6A disipan 50%
ms de calor de Categora 5e.
- S/FTP de Cat 7A disipan 60%
ms de calor de Categora 5e.
- Categora 6A y superiores para
aplicaciones de suministro de
energa.
Factores Clave
Disipacin del Calor:
- Si bien son seguras para los seres humanos, las corrientes del orden
de 600 mA asociadas con la aplicacin PoE Plus generan calor
en la planta de cableado instalada.
- La elevacin excesiva de temperatura en la planta de cableado no
puede probarse ni atenuarse en campo.
- La elevacin excesiva de temperatura en la planta de cableado puede
dar como resultado un aumento de la prdida de insercin y un
envejecimiento prematuro de los materiales de recubrimiento.
- La eleccin de materiales con un desempeo mejorado de disipacin
del calor puede minimizar los riesgos asociados con la elevacin
excesiva de temperatura.
Alien Crosstalk?
La aplicacin 10GBASE-T es muy
sensible al alien crosstalk.
Los productos compatibles necesitan
estar diseados cuidadosamente para
cumplir con los requerimientos de alien
crosstalk.
Deben seguirse las prcticas de
Victim Cable
Disturbing
Cables
Deben seguirse las prcticas de
instalacin apropiadas para ayudar
reducir el alien crosstalk.
NOTA :
Cables con mismo trenzado inducen ruido.
Seal no deseada induce un cable a otro cable.
Alta densidad de conexiones. Cat 6A FUTP
Diseo de Cableado
18
Cat 6 A F/UTP
Ground loops
Los Ground loops se generan si hay mas de una conexin a tierra y entre las dos
conexiones existe mas de 1 volt. Sin embargo el voltaje que puede ser inducido es de
60 hz y como ya vimos, es tan de bajo nivel que el balanceo del cable lo elimina
completamente. Se recomienda tanto para UTP como para FUTP verificar la
equipotencialidad del edificio por norma J-Std-607.
El blindaje ayuda a mejorar la diferencia entre tierras lo que no puede hacer el UTP.
20
Norma ANSI-J-STD-607-A define requisitos para Telecomunicaciones de Puesta a
Tierra y Unin Equipotencial en Edificios Comerciales
Requisitos especficos para el cableado de telecomunicaciones y en adicin a los
contenidos en los cdigos elctricos
Conclusiones
La capacidad de lograr buenos mrgenes de seal a ruido (SNR) depende de
dos factores, del balance y de la inmunidad a ruido provedo por el apantallado
y el blindaje
El desempeo para frecuencias mayores de 30 MHz es una preocupacin para
aplicaciones en el futuro
La diafona exgena y la inmunidad al ruido del cableado F/UTP y S/FTP resulta
en doble capacidad del canal por el teorema de Shannon
Hoy los diseos de cableado F/UTP y S/FTP ofrecen lo mejor de ambos
21
Hoy los diseos de cableado F/UTP y S/FTP ofrecen lo mejor de ambos
mundos:
El excelente balance lo cual provee proteccin a la interferencia en baja
frecuencia
El blindaje que protege de la interferencia en alta frecuencia
Industrial MAX Outlets & Plugs
Chemical-resistant, industrial-grade thermoplastic
Field or factory termination (5e)
Standard termination method
Two copper versions available
UTP: 5e and 6
F/UTP: 5e, 6 (Outlet only)
Industrial Accessories
Faceplates
Single gang (1 & 2 port)
Double gang (4 port)
Surface Mount Boxes Surface Mount Boxes
IP67 Rated
Heavy Duty PVC
1-4 outlets
Dust caps
Industrial Multimode LC
Non-conductive interface
High performance medium
Standard termination
Dual polishing puck design Dual polishing puck design
Utilizes existing LC connector design
SM outlets and adapters available as a special
Porque usar FUTP (Cat 6) o SFTP (Cat 7A)
1) Las soluciones apantalladas y las blindadas ofrecen el doble
de capacidad de transmisin que las soluciones en UTP sin
apantallar.
2) Proteccin a interferencias de ruidos EMI RFI en el ambiente.
3) Proteccin contra emisin de radiofrecuencia. 3) Proteccin contra emisin de radiofrecuencia.
4) Dimetro menor del cable para optimizacin de uso en
canalizaciones y peinado y organizado de cables. Permite
cascadas y tie wraps que no son permitidas en UTP.
5) Por su dimetro permite una fcil manipulacin y
distribucin en los organizadores
6) No calentamiento de los cables en usos de productos que
requieren de power over ethernet
Especificaciones Cat 7 & 7A
10BASE 10BASE- -T T
4 Mb/s Token Ring 4 Mb/s Token Ring
16 Mb/s Token Ring 16 Mb/s Token Ring
100Base 100Base- -T T
155 Mb/s ATM 155 Mb/s ATM
1000BASE 1000BASE- -T T
1000BASE 1000BASE- -TX TX
Categora 7 600 MHz &
1000BASE 1000BASE- -TX TX
10GBASE 10GBASE- -T T
Categora 7 600 MHz &
Categora 7A 1000 MHz
Aplicaciones divesas Aplicaciones divesas
!ideo en banda anc"a !ideo en banda anc"a
Seg#idad Seg#idad
EM$/EM% EM$/EM%
&a'os( vo) e i*age &a'os( vo) e i*age
Qu es ClaseFA/Categora 7A?
Canal construdo de componentes completamente blindados de
categora 7A
Es el de ms alto grado de performance en cable de par trenzado.
Brinda el mejor retorno a la inversin (ROI)
Ofrece el mejor comportamiento de EMC
Canal estandarizado por la ISO (clase FA/cat 7A) y especificado a
1000 mhz. Protocolo de pruebas y enlace programado para Dic
2008.
Soluciones de Cobre Punta a Punta
TERA

solucin totalmente blindada categora 7


A
/clase F
A
El sistema de par trenzado, aplicaciones 10Gb/s y superiores
Capacidad nica de aplicaciones compartidas en el mismo
cable para ahorros en costo, tiempo y espacio
Z-MAX

6ASolucin 10Gb/s cat. 6A/clase EA en F/UTP y UTP


El mejor desempeo garantizado en categora 6A
La terminacin ms rpida en categora 6A: slo 60 segundos
Premium6

, System 6

Sistema completo cat. 6/clase E UTP


Premium 5e

, System 5e

Soluciones en cobre cat. 5e/clase D,


UTP y F/UTP
Solucin Punta a Punta:
Cable, conectores, cordones, paneles
Cables Trunk Preterminados.
Technology In Progress
16 MHz 16 MHz 100 MHz 100 MHz 250 MHz 250 MHz 600 MHz 600 MHz 1.2 GHz 1.2 GHz
Standards as they are today
Where to tomorrow
Cat 3 Cat 3 Cat 5E Cat 5E Cat 6 Cat 6 Cat 7 Cat 7
7.4 mm
(.290 in)
8.3 mm
(.330 in)
Dimetro de los cables
30
5
8.5 mm
(.354 in)
Cat6A
UTP
(.290 in)
Cat6A
F/UTP
(.330 in)
Cat7
S/FTP
Datacenter
31
Sistema de cableado TERA

Ofrece ms del doble de la capacidad


Shannon de canal de la categora 6/clase E
Soporta PoE y PoE Plus
Inmune a la diafona interna y a la diafona exgena (alien crosstalk)
Garantizado para soportar 10GBASE-T
Ciclo de vida de 15 aos
32
Soporta PoE y PoE Plus
Soporta cable compartido
Seguridad incrementada debido a su
blindaje
EMI/RFI superior ideal para ambientes
ruidosos (v. gr. radiologa, aeropuertos)
CAT 7A
Aprobada bajo el estndar ISO 11801 Ad1 en Febrero del 2008, el cual
contiene las caractersticas de canal para la claseFA-/ Cat 7 A. a 1000
MHz
Con el estndar ISO-IEC 61076-3-104 sobre conectores para
1000MHz.
Sistemas blindados, Z-MAX 6A y TERA Categora 7 A permiten :
Inmunidad superior contra crosstalk
Excelente inmunidad contra ruido externo
Mrgenes ms altos de relacin seal a ruido que con categora 6A UTP
Actualizaciones de la red ms sencillas hacia 10GBASE-T
Difcil insercin de alien crosstalk
Carastersticas CAT 7A
El cableado de Categora 7A proporciona el aislamiento necesario de ruido
interno entre pares para admitir mtodos de uso compartido de cable
aprobados por las normas que reducen costos, simplifican la organizacin de
cables y soportan la convergencia de aplicaciones en un medio de par
trenzado.... es decir... tener 4 cables en 1. Ahora como no se poda hacer
antes, un usuario puede tener la oportunidad de conectar en una oficina su
computador, telfono y televisor a una sola toma en la pared conectada a un
solo cable y tener acceso a los servicios.

CAT 7A
TERA

Patch Cords
Proveen Modularidad 1-, 2- y 4-par
TERA-to-TERA
TERA-to-RJ45, RJ11
TERA-to-CATV
36
Caracteristicas Cat 7A
Para Call centers, ya no hay que enviar 4 cables por usuario sino 1 solo y de alli
conectar los telfonos los computadores y telefonos necesarios. Ejemplo: Si un
call center requiere para un agente 1 Computador 10/100, 1 telfono anlogo, 1
TV, estos 3 servicios en tecnologas anteriores requeriran de por lo menos 3
cables. Hoy con Cat 7A.... solamente 1, un conector en el faceplate y 3 patch
cords. Por otra parte si lo que se requiere es conectar telefonia anloga,
saldran 4 patch cords del mismo jack. para telefona IP, 2 patch cords del
mismo jack. El ahorro es.... muy grande no solamente en cableado sino en
canalizaciones y administracin..
CAT 7A
El ahorro en Cat 7 o Cat 7A se logra si se utilizan varios servicios desde un mismo jack.
Para esto hay que tener claro el nmero de pares que emplea un servicio:
Ahorro en el certificacin de Canal ya que el Alien Crosstalk es virtualmente cero.
Es inmune al EMI.
Call Centers
With plans for the company to move into new markets, business enabling technologies
Para salas de juntas,
Call Centers,
Business Center,
oficinas, hospitales,
salones de eventos
39
With plans for the company to move into new markets, business enabling technologies
such as streaming media, video conferencing, virtualisation and IP
telephony, were either already being tested on the network, or seen as an inevitable
acquisition for the future. The bottom line analysis showed that the Liz Earle network of
the future would transport a lot of data and some of it - for example from the graphics
team - was starting to see the transmission of single huge files (Giga/Tera Bytes) . It
was clear that the business would need high level data and telephony services for its
call centre, storage for the huge volumes of data being generated and future capacity
for the unknown, as required.
You simply cannot come along later and disrupt the business with yet another major
change."
40
Cubiculo / Oficina 1
10/100 Mbps
Cubiculo / Oficina 2
Jack entre
Cubiculos / Oficinas
Escenario:
Computadores 10/100 y telefona anloga
10/100 Mbps
Cables Cat 7
Cubiculo / Oficina 3
Cubiculo / Oficina 4
10/100 Mbps 10/100 Mbps
Cables JACK
Categoria 6A 8 8
Categoria 7A 3 3
1. Ahorro de Canalizacin
2. Ahorro mano de obra
3. Menor tiempo de instalacin
BENEFICIOS :
Cat 7A
Resumiendo:
En Cat 6A se instalaran 8 cables
En cat 7 se instalarian 3 cables.... el ahorro es enorme no solamente
en cable sino en ductos, canalizaciones, administracin,
manteniemoto, crecimiento. Ms del 35% de ahorro tomando precios
de lista de Cat 7A y si nos vamos con Cat 7 el ahorro es mucho mayor. de lista de Cat 7A y si nos vamos con Cat 7 el ahorro es mucho mayor.
Cancelacin del Ruido
Cancelacin del Ruido por DSP se realiza el
dominio de la frecuencia en todos los 4 pares
de manera simultnea utilizando el filtrado adaptativo.
El tamao y la complejidad de los canceladores
ha aumentado dramticamente para proporcionar la ha aumentado dramticamente para proporcionar la
siguientes ventajas frente a 1000BASE-T
25 db mas de cancelacion del NEXT
20 db mas de cancelacion del FEXT
20 db mas por pedida de retorno
Soluciones para el rea de trabajo y para el rack
Acomodables lado a lado (compacto/alta densidad)
Hasta 6 puertos en el WA
Mismo tamao que un RJ-45
Opciones de placas internacionales
Tapa contra polvo con identificacin de pares
Insercin en placas por el frente y por detrs
Opciones de montaje angulado, al ras, en superficie y
en rack
Comparte paneles y placas con mdulos Siemon de
44
Comparte paneles y placas con mdulos Siemon de
fibra y cobre cat 5e, 6 y 6
A
20% Ahorros de costo.
Red Convergente.
57% menos Outlets
Reduce la complejidad
Cable Sharing - 50 faceplates each
providing
1 Cat 6A UTP port
2 Cat 7 ports
150 outlets total
VoIP CCTV
Camera
10/100
BASE-T
CATV
Intercom
Camera
El DTX-1800 INTL tiene que trabajar con el cabeal TE!A "ara "o#er certi$icar Categora 7A%
http://myaccount.flukenetworks.com/fnet/en-us/supportAndDownloads/KB/Copper-Testing/DTX+CableAnalyzer/Class+Fa+-
+DTX+CableAnalyzer.htm
Conectores S/FTP
Permite utilizar un mismo
cable para mltiples
aplicaciones
10/100 LAN 10/100 LAN
Video Video
Voice Voice
Cable Shain!
20 of 27
Tasa de Transferencia: 30 Gig Tasa de Transferencia: 30 Gig
Access Point: ... 54 Mbps 74 minutos
Cat. 5/ Cat. 5e: 100 Mbps 40 minutos
Cat. 6: .................... 1Gbps 240 segundos
Cat. 6A: ............... 10 Gbps 24 segundos
*Approximation excluding encoding bits
Como Reconocer Oportunidades
Call Centers
Analogos/Digitales
TERA
Analogos/Digitales
Puertos a : 10/100 Mbps Cobre
Interfaces a: 10/100 Mbps Cobre
Como Reconocer Oportunidades
Call Centers
Telefonia IP
TERA
Telefonia IP
Puertos a : 10/100 Mbps Cobre
Interfaces a: 10/100 Mbps Cobre
Como Reconocer Oportunidades
Data Center
1000 Mhz
Interfaces a : 1 Gb Fibra o Cobre
10Gb Fibra o Cobre
52
FIBRA OPTICA
Cable de Fibra - Multimodo 50/125, 62.5/125, OM3, OM4,
Monomodo OS2
Mdulos, adaptadores y ensambles de cable MTP Plug
& Play listos para 40G y 100G
Cables trunk preterminados de rpida implementacin
Conectividad
XLR8
TM
Sistema de terminacin mecnica rpida e XLR8
TM
Sistema de terminacin mecnica rpida e
innovadora
Conectores de terminacin epxica y pulido
Jumpers y pigtails
Cajas de fibra y accesorios para empalmes
Application speeds?
40GbE Server and computing needs
Servers, high performance computing clusters,
blade servers, SANs and network attached
storage
100GbE Core networking applications
Switching, routing, and aggregation in data
centers, internet exchanges and service provider
peering points, and high bandwidth applications,
video on demand, and other high performance video on demand, and other high performance
computing environments
IEEE HSSG 802.3ba
XGLO

Fiber Assemblies
Required for XGLO warranties
DMD certified for 10 GbE support
50/125 m multimode & singlemode
SC, LC & SC-LC hybrids
Duplex jumpers; simplex pigtails
56
Duplex jumpers; simplex pigtails
Exceeds TIA and ISO/IEC requirements
for IL and RL
Telcordia and ISO/IEC end-face
geometry compliant
TERA

1000 MHz sobre Cobre


Cable Sharing
El mximo desempeo
Patch Cords hbridos
Seguro
Confiable
La Solucin
Mdulos
(Familia RIC)
Cables
Key
Conector MTP
Acopladores (Familia RIC)
Opciones de Polaridad MPO/MTP
Especificado en TIA-568-B.1-7 Guidelines For Maintaining
Optical Fiber Polarity With Systems Utilizing Array Connectors
and pending TIA-568-C.0-2009 (Annex B)
Estos son mtodos de EJEMPLOS solamente
ISO/IEC 14763-2 (new version- still under study)
Se especifican 3 Mtodos (no interoperable entre si, pero si
cambiables y adaptables) cambiables y adaptables)
Mtodo A: Mezcla de Patch cords
Mtodo B: Key matching (Llave del conector)
Mtodo C: Cruce interno en el Trunk
FTS I-Line (IBM) usa el Mtodo C como su estndar
40GBASE-SR
Mtodo A Mezcla de Patch cords
Near Far
Key UP Key UP
1 1
2 2
3 3
4 4
5 5
6 6 6 6
7 7
8 8
9 9
10 10
11 11
12 12
Nuevas soluciones para Manejo de los Cables
Espacios dedicados para Administracin y Organizacin del
Cableado
Manejo de Flujo de Aire Optimizado
Zonas dedicadas exclusivamente para el cableado
Easy access and management
Soluciones Pre-terminadas (Trunks)
Instalacin Fcil
Conectorizadas en Fbrica
Sin riesgo de terminaciones en ambientes difciles
Mayor margen
Calidad Constante
Trunks / Harness
Empacados en Fbrica
Menos desechos de Inst
Enfriamiento Mejorado
VERDE!!
Soluciones Pre-terminadas
Cmo identificar mi Red?
Para seguir un mtodo constante de identificacin
Mantener una base de datos actualizada de tus activos
de Red y el Cableado
Piense en una solucin de Administracin Inteligente:
MapIT G2!
"abinete#, $a%&# y '!ani(a)*e# de cables
Solucin de Gabinetes para Data Center VersaPOD

Las opciones de manejo de cable Zero-U aprovechan el espacio


vertical entre gabinetes contiguos para organizacin y paneles de
cableado
Liberan el espacio crtico horizontal para uso exclusivo del equipo
activo
Dan soporte y organizacin a su infraestructura de red en cualquier ambiente
activo
Flujo de aire sin obstrucciones por medio de amplios canales de
cableado sin ocupar el espacio de enfriamiento de los equipos
Racks de 2 y 4 postes profusa y funcionalmente equipados
Organizadores de cables y accesorios de montaje en rack
Canaletas(bandejas) y J-hooks RouteIT
VersaPOD en $e#umen
+ ,-# .#/a%i* Utili(able 0 ,-# '/%i*ne# )e 1i#e2*
Gracias al diseo innovador del VersaPOD, que permite mejorar la eficiencia y
organizacin de todas las configuraciones comunes del data center, el mayor beneficio
es su versatilidad
Al recuperar el espacio vertical desaprovechado en los gabinetes tradicionales, el
VersaPOD posibilita opciones de diseo antes impracticables
Esta capacidad mejorada puede aprovecharse en diseos flexibles que:
Ahorren espacio de piso de data center
Posibiliten una va de expansin fcilmente administrable para escalabilidad y expansin a futuro
Obtengan (y mantengan) la capa fsica bajo control, incluso en ambientes altamente dinmicos
Mantengan la eficiencia trmica sin sacrificar densidad
3 4e#aP'1 *5e%e el e#/a%i*6 )en#i)a) 7 e5i%ien%ia t8mi%a
ne%e#ai*# /aa la in5ae#tu%tua i)eal )e #u )ata %ente
Alta Densidad
VersaPOD
Interfaces a : 1 Gb Fibra o Cobre
10Gb Fibra o Cobre
Tempest
Cat. 7A
Z-MAX Cat. 6A F/UTP
Storages
SAN
SAN sobre 10G ip
Como Reconocer Oportunidades
SERVERs
Interfaces a :
1 Gb Fibra o Cobre
10Gb Fibra o Cobre 10Gb Fibra o Cobre
76
1. Mayor capacidad de desempeo de 10Gb/s
Muestra una Capacidad de Shannon de 23 Gbps a 500 MHz, contra tan solo 18 Gps para UTP.
2. Ciclo de vida ms largo
Una capacidad superior de 10Gb/s significa que soportar las necesidades crecientes de
desempeo de la red por
ms tiempo que otras opciones de menor rendimiento. Mientra ms dure la planta de cableado,
Las 10 Razones Principales para Implementar
una Solucin de Cableado Blindado de Cobre
para 10Gb/s
ms tiempo que otras opciones de menor rendimiento. Mientra ms dure la planta de cableado,
menor el costo total de propiedad.
3. Desempeo superior de alien crosstalk
Ofrece un total de 20dB de margen en comparacin con los lmites, casi 20dB mejor que el UTP.
4. No son necesarias las pruebas en campo de alien crosstalk
La pantalla del cable elimina el alien crosstalk al grado de no requerir pruebas.
5. Excelente inmunidad al ruido externo
La pantalla del cable protege la transmisin de la informacin de interferencia
electromagntica, permitiendo un desempeo sin errores en ambientes con ruido.
6. Mayor seguridad de la informacin
Las 10 Razones Principales para Implementar
una Solucin de Cableado Blindado de Cobre
para 10Gb/s
6. Mayor seguridad de la informacin
La misma construccin apantallada del cable que mantiene las seales externas fuera,
tambin mantiene las transmisiones dentro; asegurando la informacin contra radiaciones de
seales no deseadas.
7. Dimetros de cable ms pequeos
Dimetros de cable ms pequeos en comparacin con UTP de 10Gb/s implica que se
pueden incluir ms canales en la canalizacin y en otros espacios, sin saturaciones.
8. Menos prcticas restrictivas de instalacin
El cableado UTP depende del dimetro del forro y del espacio entre pares para cumplir con
los requisitos del alien crosstalk. Cualquier cosa que deforme el forro - radios de curvatura
Las 10 Razones Principales para Implementar
una Solucin de Cableado Blindado de Cobre
para 10Gb/s
los requisitos del alien crosstalk. Cualquier cosa que deforme el forro - radios de curvatura
excedentes, apretado del cable con velcros o cinturones, llenado de la canalizacin
sobrepasando las recomendaciones, manojos de cable muy grandes - degradar el
desempeo. El cableado F/UTP controla la diafona con un blindaje tipo pantalla,
ofrecindole mayor resistencia a los efectos negativos de la deformacin del forro.
9. Conexin a tierra simplificada
Los nuevos avances integran la mayora de requerimientos de conexin a tierra en pasos comunes
de terminacin, eliminando conjeturas y acelerando la instalacin.
10. Adopcin creciente en el mercado
El crecimiento de los sistemas apantallados de 10Gb/s sobrepasa ahora el crecimiento del UTP de
10Gb/s en Norte Amrica.10G 6A F/UTP MC

Modular patch cords


10G 6A F/UTP BladePatch

para aplicaciones de alta densidad


Las 10 Razones Principales para Implementar
una Solucin de Cableado Blindado de Cobre
para 10Gb/s
10G 6A F/UTP BladePatch para aplicaciones de alta densidad
Construccin multifilar (stranded)
Construccin doblemente blindada para desempeo ptimo en alien crosstalk
Dimetro del cable 6.1 mm (0.24 plgs)