Sie sind auf Seite 1von 2

POWER

+
SA
30kVA & 40kVA modules
Available in 3/3
Unique light and compact design - only 68Kg!
Great performance:
High efficiency AC/AC: 96%
Low input THDi: 5%
Input PF: 0.99
Back light LCD
10kVA redundancy inverters and rectifiers
ON-LINE DOUBLE CONVERSION UPS
True on-line battery
GAMATRONIC
Our Power, Your Confidence
According to IEC 62040-3
AC Input
AC Output
Battery
DC link
Rectifier Inverter
Double Conversion True On-Line Battery (VFI)
Topology
INPUT
Voltage
Voltage Range
Power Walk-In
Power Factor
THDI
Earth Leakage Current
OUTPUT
Rated Power
Frequency Tracking Range
Slew Rate
Voltage
Static Regulation
Regulation for Unbalanced Load
Dynamic Response to 100% Load Step
Overload
Waveform
THD
Load CF (max)
DC/AC Efficiency (nominal)
AC/AC Efficiency (nominal)
STATIC SWITCH (bypass)
Input Connection
GENERAL
Maximum Power Dissipation (Po=8KW)
Ambient Temperature
Relative Humidity
Altitude
Enclosure
Cooling System
Acoustic Noise (Full load) @1.5m distance
MTBF
Dimensions (H x W x D) (cm)
Weight (electronic cabinet)

True Online Battery, Double Conversion
1 or 3 phase+N 3 phase+N
3X400 V + N; 45-65 Hz
-27% +20%
> 60 sec
0.99
5%
3mA max
3 phase+N
30 kVA / 24 kW 40 kVA / 32 kW
1, 2, 3Hz (selectable)
1 Hz/sec
3X400 V + N; 50 Hz
1 %
1 % for 100% Unbalanced load
2 %
110 % for 10 min.; 125 % for 60 sec.; 1000 % for 1 cycle
Sinusoidal
Less than 2% for linear load
6:1
98 %
96 %
Dual Input
999W (3408 BTU) 1332W (4544 BTU)
-10
o
to +40
o
(operating); -20
o
to +70
o
(storage)
95% max non-condensation
1500 without derating
IP20
Multi-Fan with speed control (forced)
48dBA
250,000 hrs
66 x 48 x 58
68Kg
yes
yes
option
Voltage, Frequency, Current
Voltage, Frequency, Current
Voltage
Last 256 Events
EN50091-2 Class A ; IEC 62040-2
EN50082-2
E50091-1 ; IEC 62040-1-1
EN50091-3 ; IEC 62040-3
EMF as per ICNIRP
Sealed, valve regulated, lead-acid
64x12V
5 min. at 100% load; 15 min. at 50% load
Approx. 1-2 hrs.
POWER
+
SA UPS

COMMUNICATION
RS232
Alarm - Shutdown Monitor
SNMP
LCD DATA DISPLAY
Input
Output
Batteries
Log (events memory)
STANDARDS
EMC Emission
EMC Immunity
Safety
Design
Low Magnetic Field Radiation
BATTERIES (external)
Type
Number
Backup Time
Recharge Time
* All specifications are typical and subject to change without prior notice
June 2008
w
w
w
.
g
a
m
a
t
r
o
n
i
c
.
c
o
m

3 0 k VA
H
e
a
d
q
u
a
r
t
e
r
s

a
n
d

F
a
c
t
o
r
y


1
4

H
a
r
t
o
m

S
t
.

P
O
B

4
5
0
2
9
,

J
e
r
u
s
a
l
e
m

9
7
7
7
4
,

I
s
r
a
e
l


T
e
l
:

+
9
7
2
-
2
-
5
8
8
8
2
2
2


F
a
x
:

+
9
7
2
-
2
-
5
8
2
8
8
7
5


e
-
m
a
i
l
:

i
n
f
o
@
g
a
m
a
t
r
o
n
i
c
.
c
o
.
i
l

w
w
w
.
g
a
m
a
t
r
o
n
i
c
.
c
o
m
T
e
l
-
A
v
i
v

S
a
l
e
s

O
f
f
i
c
e


3
4

H
a
b
a
r
z
e
l

S
t
.

R
a
m
a
t

H
a
c
h
a
y
a
l
,

T
e
l

A
v
i
v


T
e
l
:

+
9
7
2
-
3
-
6
4
9
9
9
4
0


F
a
x
:

+
9
7
2
-
3
-
6
4
4
9
7
9
1

G
A
M
A
T
R
O
N
I
C

E
L
E
C
T
R
O
N
I
C

I
N
D
U
S
T
R
I
E
S

L
T
D
.
G
a
m
a
t
r
o
n
i
c

U
K

L
t
d
.


1
5

C
h
e
s
t
e
r

R
o
a
d
,

C
o
l
m
w
o
r
t
h

B
u
s
i
n
e
s
s

P
a
r
k
,

E
a
t
o
n

S
o
c
o
n
,

C
a
m
b
r
i
d
g
e
s
h
i
r
e
,

P
E
1
9

8
Y
T
,

U
n
i
t
e
d

K
i
n
g
d
o
m


T
e
l
:

+
4
4

(
0
)
1
4
8
0

4
7
9
8
8
9
/

4
7
2
6
6
5


F
a
x
:

+
4
4
(
0
)
1
4
8
0

4
0
7
8
6
5


i
n
f
o
@
g
a
m
a
t
r
o
n
i
c
.
n
e
t

4 0 k VA
Specifications

Das könnte Ihnen auch gefallen