Products manufactured in an ISO certed facility. This document contains the most current product informaton as of this printng. 2014-07 Ducted Split B Series Ducted Split B Series RC150D RC75/100/125B FD125/150B FD75/100B 2FD200B 2FG250B 3FG350B 4FG400B 4FG500B Wide Range Of Product Modular Combinaton Of Single Indoor Unit To Multple Outdoor Units Partal Loading Features For Units With More Than 2 Outdoor Units Convertble Air Discharge Changeable Drive Package (Field Supplied) For Belt Driven Models Single Compressor System: Wired Handset BRC51B64 Is Supplied As Standard Mult Compressor System: Wired Handset BRC51C61 Is Supplied As Standard Specicaton for Ducted Split - B Series - Cooling only Components Expansion device: Thermal expansion valves are supplied as standard. Compressor: Each high eciency scroll type compressor is hermetcally sealed, quiet running and supported on rubber mounts to minimize vibraton. Indoor fan: A dynamically balanced forward curved fan with a eld changeable pulley package, in order to match the designed supply air requirements. Condenser fan blade: Use of well designed propeller fan blade has eectvely reduce the sound pressure level. Refrigeraton The outdoor units are come with factory Nitrogen holding charge. Installer will need to charge the HCFC-22 (R-22) refrigerant at site according to the manual recommendaton Long Piping Applicaton Standard maximum piping length of Daikin ducted split is up to 35mfor Cooling Only model. Safety Features High Pressure and Low Pressure protecton. Compressor & motor current overload protecton. Sensor fault indicaton. Minimumcompressor running tme to ensure oil return. Phase sequental is used to detect for any wrong phase and phase loss during installaton and operaton Command Performance Standard units are equipped with microprocessor controller and it is equipped with following functons: Mode selecton Temperature Setng Timer (delay tmer for BRC51B and real tme tmer for BRC51C) Error code display Auto-Random Restart Whenever unit stop due to power failure during operaton unit automatcally restarts at last setng conditon once the power is resumed. However, the compressors will restart randomly if more than one unit is installed and share the same phase of power. Opton is provided to cancel this feature. Cabinet Constructon Either indoor or outdoor is coated with weatherproofed electro galvanized mild steel casing, with an epoxy is coated with an epoxy polyester powder costng for severe external conditons. Service Panel is available at the convenience side for both indoor and outdoor. Indoor Air Throw Directon Convertble discharge air directon at indoor unit has made it versatle to various architectural designs. (Applicable to size 125 and above only) Changeable Drive Package Non-standard external statc pressure & airow requirement can be sized by changing the factory ted drive package. (Limited for belt drive model only) Easy To Reach Access Valve Discharge line and sucton line access valve is accessible without opening the unit casing. Insulaton Polyethylene (PE) insulaton is used at every possible condensate panel to prevent all forms of water or moisture penetraton. Polyethylene, which is also a type of Closed Cell Foam(CCF) insulaton has oered the following advantages: Durable external surface that resists dirt tough and resilient Higher degree of puncture resistance when compared to berglass Easily cleaned surface (if necessary) to further resist microbial growth Choices Of Wired Controller BRC51B64 (C/0) BRC51C61 FD75BXVL FD100BXVL RC75BXTL9 RC100BXTL9 FD125BXTL RC125BXTL9 FD150BXVL RC150DXTL9 Btu/h 73000 21400 2.63 220/1/60 2500 98/71/49 50/50/48 572 1402 605 89 220/3N~/60 65 946 939 1116 155 90000 26380 2.67 220/1/60 3200 98/78/61 53/51/49 572 1402 605 93 220/3N~/60 61 946 939 1116 164 118000 34580 2.45 220/3N~/60 4200 150 58 885 1540 850 183 220/3N~/60 65 946 939 1116 169 148000 43380 2.92 220/3N~/60 4600 150 60 885 1540 850 190 220/3N~/60 67 1142 1083 1083 268 W W/W Power Supply V/Ph/Hz Air Flow CFM External Statc Pressure Pa Sound Pressure Level dBA Height mm Width mm Depth mm Net Weight kg Power Supply V/Ph/Hz Sound Pressure Level dBA Height mm Width mm Depth mm Net Weight kg Indoor Model Name Outdoor Model Name Nominal Cooling Capacity Nominal EER In d o o r O u td o o r 2FD200BXTL RC100BXTL9 X 2 2FG250BXTL RC125BXTL9 X 2 2FG300BXTL RC150DXTL9 X 2 3FG350BXTL RC100BXTL9 + RC125BXTL9 X 2 Btu/h 180000 52760 2.65 220/3N~/60 6400 150 61 885 1794 850 220 220/3N~/60 65 946 939 1116 164 236000 69170 2.42 220/3N~/60 8000 200 63 1231 1766 1069 343 220/3N~/60 65 946 939 1116 169 296000 86750 2.85 220/3N~/60 9000 200 66 1231 1766 1069 343 220/3N~/60 67 1142 1083 1083 268 326000 95550 2.34 220/3N~/60 10500 200 66 1486 2022 1069 462 220/3N~/60 65 946 939 1116 164 + 169 W W/W Power Supply V/Ph/Hz Air Flow CFM External Statc Pressure Pa Sound Pressure Level dBA Height mm Width mm Depth mm Net Weight kg Power Supply V/Ph/Hz Sound Pressure Level dBA Height mm Width mm Depth mm Net Weight kg Indoor Model Name Outdoor Model Name Nominal Cooling Capacity Nominal EER In d o o r O u td o o r 4FG400BXTL RC100BXTL9 x 4 3FG450BXTL RC150DXTL9 x 3 4FG500BXTL RC125BXTL9 x 4 Btu/h 444000 130130 2.86 220/3N~/60 13500 250 68 1486 2174 1336 564 220/3N~/60 67 1142 1083 1083 268 472000 138340 2.35 220/3N~/60 15000 250 68 1486 2174 1336 606 220/3N~/60 65 946 939 1116 169 W W/W Power Supply V/Ph/Hz Air Flow CFM External Statc Pressure Pa Sound Pressure Level dBA Height mm Width mm Depth mm Net Weight kg Power Supply V/Ph/Hz Sound Pressure Level dBA Height mm Width mm Depth mm Net Weight kg Indoor Model Name Outdoor Model Name Nominal Cooling Capacity Nominal EER In d o o r O u td o o r Single Condenser System - FD Mult Condenser System - 2FD, 2FG, 3FG, 4FG 360000 105510 2.73 220/3N~/60 12000 200 66 1486 2174 1336 513 220/3N~/60 65 946 939 1116 164 Max. Allowable Length Max. Allowable Elevaton m m 50 20 50 20 50 20 50 20 Max. Allowable Length Max. Allowable Elevaton m m 50 20 50 20 50 20 50 20 Max. Allowable Length Max. Allowable Elevaton m m 50 20 50 20 50 20