Sie sind auf Seite 1von 2

Flow and Pressure Control Valves

 Shown from left to right: V-152, V-66, V-82, V-161, V-42, V-17

Your Hydraulic
Control Solution

The V-152 Pressure Relief Valve limits


the pressure or force developed in the
hydraulic system.

• All valves are rated for 10,000 psi operating pressure


Valve Applications
• All valves feature NPTF porting to insure against
To see these valves used
leakage at rated pressure in typical hydraulic circuits,
• All valves are painted, coated, or plated for please see our “Yellow Pages”.
corrosion resistance
Page: 252

2.50
1.25

1/2"-

3.50
14NPTF
1.25

.63
3/8"-18NPTF 1/4"-18NPTF 3/8"-18NPTF 2.50 1.44
1.25 1/2"-14NPTF
V-82 V-182 V-8F V-91

3/8"-
18NPTF

3/8"-18NPTF
1/2"-14NPTF

V-10 V-17 V-42


2.00
4.00

4.00
4.37
2.00

2.00
2.00

3.50 2.25 3.50 2.25


3.50 2.25 3/8"-18NPTF (3x)
3/8"-18NPTF 1.00 3/8"-18NPTF 1.00
3/8"-18NPTF 1.00

V-66 V-66F V-152 V-161


Valve Dimensions in inches.

132 www.enerpac.com
Flow and Pressure Control Valves
Premounted Manifold Fittings V
For two or four port For additional fittings
manifold with integral see the fitting page
Series
flow control valves, see of the System
the manifold page of the Components section.
System Components section.
Page: 122 Page: 123

Maximum Operating Pressure:


10,000 psi
Valve Type and Description Hydraulic
Model Number Symbol

Needle Valve V-82: To control cylinder speed. " NPTF female ports. Also suitable
V-82 Can also be used as shut-off valve for gauge snubbing.
for temporary load holding. V-8F: Similar to V-82, but with very
V-182F
" NPTF female ports. fine metering for precise flow control.
V-8F V-182: Same as V-82, but with Not recommended as shut-off valve.

Snubber V-91: Adjustable for metering oil the gauge during high cycling
Valve out of a gauge to prevent snapping applications. " NPTF male and
of gauge pointer when load or female threads for use with GA-1,
V-91
pressure is suddenly released. Also GA-2 or GA-4 gauge adaptors.
suitable as shut-off valve to protect

V-10: To be used when gauge No adjustments are necessary.


Auto
pressure must be monitored during " NPTF male and female threads for
Damper®
high cycle applications. Creates use with GA-1, GA-2 or GA-4 gauge
Valve
a flow resistance when load is adaptors.
V-10 released suddenly.

V-17: Ruggedly built to resist shock


Check
and operate with low pressure drop.
Valve Closes smoothly without pounding.
V-17
" NPTF female ports.

V-42: Can be mounted at the from a Tee-fitting in the cylinder


Pilot Operated
Check Valve cylinder to hold the load in case of retract line.
system pressure loss. Normally " NPTF female ports.
V-42 used with double-acting cylinders Pilot pressure ratio 14% (6.5:1).
where pilot port receives pressure

Manually Operated V-66: Used for load holding V-66F: Similar to V-66, but with very
Check Valve applications with single and double fine metering capability for precise
acting cylinders. Valve is manually flow control.
V-66* opened to allow oil to flow back to Not designed for load holding
V-66F tank when cylinder retracts. applications.

Pressure Relief V-152: Limits pressure developed To increase pressure setting, turn
Valve by the pump in hydraulic circuit, thus handle clockwise. Includes:
limiting the force created by other • 3 ft return line hose kit
V-152* components. Valve opens whenever • ±3% repeatability
preset pressure is reached. • 800-10,000 psi adjustment range.

V-161: To control oil flow to a allow flow to the secondary circuit.


Sequence Valve
secondary circuit. Flow is blocked A pressure differential is always
V-161
until system pressure rises to the maintained between the primary P A
V-161 setting. When this pressure and secondary circuit.
level is reached, the V-161 opens to Min. operating pressure: 2000 psi.
* See page 56-57 for more information on extreme pressure and flow control valves.

® 133