Indoor unit

0CVP0-02C(Replaces:0CVP0-02B)
Indoor unit
(R410A)
LG Airconditioners Product Data
Introduction
General Information
Indoor Units
Dip Switch &
Group Control Setting
Introduction
1. Preface
R410A Model
is the most favored choice when there is a need for precise air conditioning of relatively big
projects extending from Multi-Room structure to big commercial places. We have a big line up, that offers wider
flexibility of model selection.
Equipped with inverter technology and long piping installation, the product matches well if one talk about opti-
mum power consumption in high rise buildings. Add on capacity feature makes it easy to upgrade the existing
capacity at any time.
With the growing concern about environment preservation, comes with R410A refrigerant which
is environment friendly and thus our system is a high technology and environment friendly prod-
uct.
Unique refrigerant flow and electronic circuit control gives this system an unique capability to work in
extreme/abnormal working conditions making our customer feel great about their decision of selecting
LG as their first choice.
This publication provides a detailed and in depth information about the design and installation of
.
We hope that with this information you would become an expert of your system.
Air-Conditioning Company
2. Step by Step System Selection Process
(1)
Calculate or obtain the maximum heat load for the area(s) to be air conditioned
Decide the indoor unit specifications
Decide the outdoor unit specifications
(2)
(3)
(4)
Capacity coefficient factor
Decide the air velocity and temperature distributions
Selection of the control system
Control wiring method
Description of devices
Selection of refrigerant pipe joints and headers
(5) Electrical wiring
Electric characteristics
Field wiring
! Caution
1. Air conditioners should not be installed in areas where corrosive gas such as acid gas
or alkaline gas is produced.
2. If the outdoor unit is installed close to the sea shore, direct exposure to the sea breeze
should be avoided and choose an outdoor unit with anti-corrosion treatment.
Indoor unit
General information
General Information
1. Model Names
2. External Appearance
3. Nomenclature
4. Indoor Unit Capacity Index
Indoor unit
Indoor unit
General information
1 1
1. Model Names
SE
Wall Mounted
(General)
S5
SE
Mirror
S8
SF
1 Way
TU
TT
2 Way TL
TR
TQ
4 Way
TP
TN
TM
BH
BG
High
Static
BR
B8
B1
Low Static
B2
B3
B4
Ceiling & Floor VE
Ceiling Suspended VJ
CE
With Case
CF
CE
CF
Capacity(Btu/h(kW))
Category Chassis
Name
5k 7k 9k 12k 15k 18k 24k 28k 36k 42k 48k 76k 96k
(1.6) (2.2) (2.8) (3.6) (4.5) (5.6) (7.1) (8.2) (10.6) (12.3) (14.1) (22.4) (28.0)
Ceiling
Concealed
Duct
Built In
Gallery
Floor
Standing
Without
Case
Ceiling
Cassette
ART COOL
*ART COOL- SE/S8( * R:Mirror, V:Silver, B : Blue), SF(* E:Red, V:Silver, G:Gold , 1: Kiss (Photo changeable))
*Wall Mounted- A: Basic, L:Plasma
*Ceiling Cassette- A: Basic, C:Plasma
ARNU07G
SE*2
ARNU09G
SE*2
ARNU12G
SE*2
ARNU15G
SE*2
ARNU07G
GTU*2
ARNU09G
GTU*2
ARNU12G
GTU*2
ARNU18G
TL*2
ARNU24G
TL*2
ARNU18G
TT*2
ARNU24G
TT*2
ARNU05
GTR*2
ARNU07G
TR*2
ARNU09G
TR*2
ARNU12G
TR*2
ARNU15
GTQ*2
ARNU18G
TQ*2
ARNU24G
TP*2
ARNU28G
TP*2
ARNU07G
BHA2
ARNU09G
BHA2
ARNU12G
BHA2
ARNU15G
BHA2
ARNU18G
BHA2
ARNU24G
BHA2
ARNU07
GB1G2
ARNU09
GB1G2
ARNU12
GB1G2
ARNU15
GB1G2
ARNU07G
B3G2
ARNU09G
B3G2
ARNU12G
B3G2
ARNU15G
B3G2
ARNU07G
CEA2
ARNU09G
CEA2
ARNU12G
CEA2
ARNU15G
CEA2
ARNU07G
CEU2
ARNU09G
CEU2
ARNU12G
CEU2
ARNU15G
CEU2
ARNU09G
VEA2
ARNU12G
VEA2
ARNU18G
VJA2
ARNU24G
VJA2
ARNU18G
CFA2
ARNU24G
CFA2
ARNU18G
CFU2
ARNU24G
CFU2
ARNU28G
BGA2
ARNU36G
BGA2
ARNU42G
BGA2
ARNU36G
TN*2
ARNU48G
BRA2
ARNU42G
TM*2
ARNU48G
TM*2
URNU76G
B8A2
URNU96G
B8A2
ARNU18
GB2G2
ARNU24
GB2G2
ARNU18G
B4G2
ARNU24G
B4G2
ARNU07G
SE*2
ARNU09G
SE*2
ARNU12G
SE*2
ARNU15G
SE*2
ARNU07G
SF*2
ARNU09G
SF*2
ARNU12G
SF*2
ARNU18G
S5*2
ARNU24G
S5*2
ARNU18G
S8*2
ARNU24G
S8*2
Indoor unit
Wall Mounted
ART COOL Mirror
Ceiling Cassette- 1Way
Ceiling Cassette- 4Way
Ceiling & Floor
Ceiling Suspended
ARNU07GTU*2
ARNU09GTU*2
ARNU12GTU*2
ARNU18GTT*2
ARNU24GTT*2
Ceiling Cassette -2Way
ARNU18GTL*2
ARNU24GTL*2
ARNU05GTR*2
ARNU07GTR*2
ARNU09GTR*2
ARNU12GTR*2
ARNU15GTQ*2
ARNU18GTQ*2
ARNU24GTP*2
ARNU28GTP*2
ARNU36GTN*2
ARNU42GTM*2
ARNU48GTM*2
Ceiling Concealed Duct - Low Static
ARNU07GB1G2
ARNU09GB1G2
ARNU12GB1G2
ARNU15GB1G2
ARNU18GB2G2
ARNU24GB2G2
ARNU07GSE*2
ARNU09GSE*2
ARNU12GSE*2
ARNU15GSE*2
ARNU18GS5*2
ARNU24GS5*2
ARNU07GSE*2
ARNU09GSE*2
ARNU12GSE*2
ARNU15GSE*2
ARNU18GS8*2
ARNU24GS8*2
ARNU09GVEA2
ARNU12GVEA2
ARNU18GVJA2
ARNU24GVJA2
Floor Standing
With case
ARNU07GCEA2
ARNU09GCEA2
ARNU12GCEA2
ARNU15GCEA2
ARNU18GCFA2
ARNU24GCFA2
Without case
ARNU07GCEU2
ARNU09GCEU2
ARNU12GCEU2
ARNU15GCEU2
ARNU18GCFU2
ARNU24GCFU2
Ceiling Concealed Duct - High Static
ARNU07GBHA2
ARNU09GBHA2
ARNU12GBHA2
ARNU15GBHA2
ARNU18GBHA2
ARNU24GBHA2
ARNU28GBGA2
ARNU36GBGA2
ARNU42GBGA2
ARNU48GBRA2
URNU76GB8A2
URNU96GB8A2
Ceiling Concealed Duct Built-in
ARNU07GB3G2
ARNU09GB3G2
ARNU12GB3G2
ARNU15GB3G2
ARNU18GB4G2
ARNU24GB4G2
* A:Basic, L:Plasma
ART COOL Gallery
ARNU07GSF*2
ARNU09GSF*2
ARNU12GSF*2
* E:Red V:Silver
G:Gold 1: Kiss (Photo changeable)
* A:Basic, C:Plasma
* A:Basic, C:Plasma
* R:Mirror
V:Silver
B:Blue
* A:Basic, C:Plasma
2. External Appearance
General information
2 2
Indoor unit
ARN U G 07 A TU 2
Serial Number
Chassis Name
Electrical Ratings
2: 1, 220V, 60Hz
6:1, 220 - 240V, 50Hz
G:1, 220 - 240V, 50Hz / 1, 220V, 60Hz
Total Cooling Capacity in Btu/h
EX) 5,000 Btu/h'05' 18,000 Btu/h'18'
Combination of Inverter Type and
Cooling Only or Heat Pump
N: AC Inverter and H/P V: AC Inverter and C/O
U: DC Inverter and H/P and C/O
System with
Indoor Unit using R410A
LGETA:U Ex) URN
Combinations of functions
A:Basic function
L:Neo Plasma(Wall Mounted)
C:Plasma(Ceiling Cassette)
G: Low Static
U : Floor Standing without Case
ART COOL Type Panel Color
SE/S8 - R:Mirror V:Silver B:Blue
SF - E:Red V:Silver G:Gold 1: Kiss (Photo changeable)
General information
3 3
3. Nomenclature
Indoor unit
4. Indoor Unit Capacity Index
General information
4 4
Capacity
Index
Unit Capacity
(Btu/h)
5k 7k 9k 12k 15k 18k 24k 28k 36k 42k 48k 76k 96k
1.6 2.2 2.8 3.6 4.5 5.6 7.1 8.2 10.6 12.3 14.1 22.4 28.0
INDOOR UNIT CAPACITY INDEX
Capacity Index is same as the capacity(kW).
Indoor unit
Indoor Units
Ceiling Cassette 1-Way
Ceiling Cassette 2-Way
Ceiling Cassette 4-way
Ceiling Concealed Duct(High Static)
Ceiling Concealed Duct(Low Static)
Ceiling Concealed Duct(Built in)
Wall Mounted
ART COOL Mirror
ART COOL Gallery
Ceiling & Floor/Ceiling Suspended
Floor Standing
Indoor unit
Indoor unit
Ceiling Cassette 1-way
C
a
s
s
e
t
t
e

1
-
w
a
y
1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. Air Velocity and Temperature Distribution
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories
Ceiling Cassette 1-Way
Indoor unit
1. List of functions
Ceiling Cassette 1-way
1-1 1-1
C
a
s
s
e
t
t
e

1
-
w
a
y
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Air flow
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Air purifying Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
Installation
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Reliability Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Convenience Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Individual Simple wired remote controller
control Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Special
Zone control
function kit
CTIE
Electro thermostat
1
-
Auto
-
O
4 / 5 / 4
X
O
O
-
X
Option
O
O
O
X
O
O
O
O
O(Heat recovery)
X
O(Heat pump or Cooling only)
O
O
O
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
X
Accessory
-
-
-
Function Category
ARNU07GTU*2, ARNU09GTU*2, ARNU12GTU*2
ARNU18GTT*2, ARNU24GTT*2
O : Applied X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.
* Some functions can be limited by remote controller.
Indoor unit
2. Specifications
Ceiling Cassette 1-way
1-2 1-2
C
a
s
s
e
t
t
e

1
-
w
a
y
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Body
mm
Dimensions (WxDxH)
inch
Front Panel
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Fan Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight Body kg(lbs)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable
Transmission cable
Panel Color
Panel Name(Accessory)
1Way Ceiling Cassette
ARNU07GTU*2 ARNU09GTU*2 ARNU12GTU*2
2.2 2.8 3.6
1,900 2,400 3,100
7,500 9,600 12,300
2.5 3.2 4.0
2,200 2,800 3,400
8,500 10,900 13,600
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
860 x 450 x 132 860 x 450 x 132 860 x 450 x 132
33.8 x 17.7 x 5.2 33.8 x 17.7 x 5.2 33.8 x 17.7 x 5.2
1100 x 500 x 34 1100 x 500 x 34 1100 x 500 x 34
43.3 x 19.7 x 1.3 43.3 x 19.7 x 1.3 43.3 x 19.7 x 1.3
2 x 12 x 18 2 x 12 x 18 2 x 12 x 18
0.16 0.16 0.16
Cross Flow Fan Cross Flow Fan Cross Flow Fan
30 30 30
0.18 0.18 0.18
8.2 / 7.3 / 6.4 9.2 / 8.6 / 8.2 10 / 9.2 / 8.2
289.5 / 257.7 / 225.9 324.7 / 303.6 / 289.5 353 / 324.8 / 289.5
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene
Fuse Fuse Fuse
6.35(1/4) 6.35(1/4) 6.35(1/4)
12.7(1/2) 12.7(1/2) 12.7(1/2)
25(1) 25(1) 25(1)
14.7(32.4) 14.7(32.4) 14.7(32.4)
32 / 29 / 25 35 / 34 / 32 38 / 35 / 32
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Morning fog Morning fog Morning fog
PT-UUC
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are Net Capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
* Model Name
A:Basic, C:Plasma
Indoor unit
Ceiling Cassette 1-way
1-3 1-3
C
a
s
s
e
t
t
e

1
-
w
a
y
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Body
mm
Dimensions (WxDxH)
inch
Front Panel
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Fan Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight Body kg(lbs)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable
Transmission cable
Panel Color
Panel Name(Accessory)
1Way Ceiling Cassette
ARNU18GTT*2 ARNU24GTT*2
5.6 7.1
4,800 6,100
19,100 24,200
6.3 7.1
5,400 6,100
21,500 24,200
Galvanized Steel Plate Galvanized Steel Plate
1180 x 450 x 132 1180 x 450 x 132
13.3 x 17.7 x 5.2 46.5 x 17.7 x 5.2
1420 x 500 x 34 1420 x 500 x 34
55.9 x 19.7 x 1.3 55.9 x 19.7 x 1.3
2 x 12 x 18 2 x 12 x 18
0.24 0.24
Cross Flow Fan Cross Flow Fan
30 30
0.30 0.30
13.3 / 12.1 / 10.9 14.6 / 13.3 / 11.5
515.4 / 427.1 / 384.8 575.4 / 469.5 / 406
Direct Direct
BLDC BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene
Fuse Fuse
6.35(1/4) 9.52(3/8)
12.7(1/2) 15.88(5/8)
25(1) 25(1)
18.7(41.23) 18.7(41.23)
40 / 37 / 35 43 / 40 / 36
1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60
EEV EEV
CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Morning fog Morning fog
PT-UTC
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are Net Capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
* Model Name
A:Basic, C:Plasma
Indoor unit
3. Dimensions
Ceiling Cassette 1-way
1-4 1-4
C
a
s
s
e
t
t
e

1
-
w
a
y
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

T
U
C
e
i
l
i
n
g

C
a
s
s
e
t
t
e

1
-
w
a
y
A
R
N
U
0
7
G
T
U
*
2
A
R
N
U
0
9
G
T
U
*
2
A
R
N
U
1
2
G
T
U
*
2
N
a
m
e
1
L
i
q
u
i
d

p
i
p
e

c
o
n
n
e
c
t
i
o
n
U
n
i
t

s
i
z
e
(
7
k
,

9
k
,

1
2
k
)
:

6
.
3
5
2
G
a
s

p
i
p
e

c
o
n
n
e
c
t
i
o
n
U
n
i
t

s
i
z
e
(
7
k
,

9
k
,

1
2
k
)
:

1
2
.
7

3
A
i
r

s
u
c
t
i
o
n

g
r
i
l
l


4
A
i
r

d
i
s
c
h
a
r
g
e

g
r
i
l
l

N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
(
u
n
i
t

:

m
m
)
4 4
3 4
4 6 . 5
5 0 0
1
1
0
0
1 6 8 . 3
1 0 6 . 8
2 0 6 . 6
2 7 5 . 8
9 6 . 5
5 7 . 4
1
0
9
.
5
4
5
3
2
7
3
2
0
.
5
1
0
1
2
8
8
8
6
1
1
0
9
.
5
Indoor unit
Ceiling Cassette 1-way
1-5 1-5
C
a
s
s
e
t
t
e

1
-
w
a
y
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

T
T
C
e
i
l
i
n
g

C
a
s
s
e
t
t
e

1
-
w
a
y
A
R
N
U
1
8
G
T
T
*
2
A
R
N
U
2
4
G
T
T
*
2
N
a
m
e
1
L
i
q
u
i
d

p
i
p
e

c
o
n
n
e
c
t
i
o
n
U
n
i
t

s
i
z
e
(
1
8
k
)
:

6
.
3
5
,

(
2
4
k
)
:

9
.
5
2
2
G
a
s

p
i
p
e

c
o
n
n
e
c
t
i
o
n
U
n
i
t

s
i
z
e
(
1
8
k
)
:

1
2
.
7
,

(
2
4
k
)
:

1
5
.
8
8

3
A
i
r

s
u
c
t
i
o
n

g
r
i
l
l


4
A
i
r

d
i
s
c
h
a
r
g
e

g
r
i
l
l

N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
(
u
n
i
t

:

m
m
)
4 4
3 4
5 0 0
4 6 . 5
2 0 . 6
6 5 . 3
1 8 0 . 6
2 4 7 . 5
4 5 3 . 8
5 7 . 4
9 1
9 6 . 1
1 7 3 . 8
3 1 . 7
1
0
9
.
5
4
5
3
.
8
1
0
9
.
5
1
4
2
0
6
5
.
1
1
3
3
2
1
1
7
6
.
4
Indoor unit
4. Piping Diagrams
Ceiling Cassette 1-way
1-6 1-6
C
a
s
s
e
t
t
e

1
-
w
a
y
Heat Exchanger
C.F.F.
lndoor unit
EEV
Filter
Filter
Th3 Th2
Th1
:Heating
:Cooling
Refrigerant pipe connection port diameter
Model
ARNU07GTU*2
ARNU09GTU*2
ARNU12GTU*2
ARNU18GTT*2
ARNU24GTT*2
Gas
12.7(1/2)
15.88(5/8)
Liquid
6.35(1/4)
9.52(3/8)
[Unit: mm(inch)]
LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor
Indoor unit
5. Wiring Diagrams
Ceiling Cassette 1-way
1-7 1-7
C
a
s
s
e
t
t
e

1
-
w
a
y
CONNECTOR NUMBER LOCATION POINT FUNCTION
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC output for drain pump
CN-485 Communication Connection between indoor and outdoor
CN-DISP Display Display of indoor status
CN-EEV EEV Output EEV Control output
CN-VANE2 Step motor Step motor output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room air thermistor
CN-REMO Remote controller Remote control line
CN-CC Dry contact Dry contact line
CN-OPTION Option pwb. Communication between main and option
CN-COM Communication Communication between indoor and outdoor
CN-VANE1 Step motor Step motor output
TU, TT Chassis
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor
CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.
Indoor unit
6. Capacity Tables
Ceiling Cassette 1-way
1-8 1-8
C
a
s
s
e
t
t
e

1
-
w
a
y
6.1 Cooling Capacity
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
2.8
3.6
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
10 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.9 1.7
12 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.9 1.6
14 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.8 1.6
16 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.8 1.6
18 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.6
20 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.6
21 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.5
23 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.6 1.5
25 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.6 1.5
27 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.6 1.5
29 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.5 1.5
31 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.5 1.4
33 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.5 1.4
35 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.4 1.4
37 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.4 1.4
39 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.3 1.4
10 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.7 2.1
12 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.6 2.1
14 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.6 2.1
16 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.5 2.0
18 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.5 2.0
20 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 2.0
21 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 2.0
23 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 1.9
25 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.3 1.9
27 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.3 1.9
29 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.2 1.9
31 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.2 1.8
33 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.1 1.8
35 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.1 1.8
37 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.0 1.8
39 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.0 1.7
10 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.7 2.7
12 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.7 2.7
14 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.6 2.7
16 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.6 2.6
18 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.5 2.6
20 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.4 2.5
21 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.4 2.5
23 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.3 2.5
25 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.3 2.5
27 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.2 2.4
29 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.2 2.4
31 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.1 2.4
33 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.0 2.3
35 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.0 2.3
37 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 3.9 2.3
39 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 3.8 2.2
2.2
Cooling capacity
Indoor unit
Ceiling Cassette 1-way
1-9 1-9
C
a
s
s
e
t
t
e

1
-
w
a
y
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
7.1
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
10 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.4 4.2
12 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.3 4.1
14 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.2 4.1
16 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.1 4.0
18 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.0 4.0
20 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.9 3.9
21 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.8 3.9
23 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.7 3.8
25 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.6 3.8
27 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.6 3.7
29 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.5 3.7
31 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.4 3.6
33 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.3 3.6
35 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.2 3.5
37 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.1 3.5
39 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.0 3.4
10 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 9.3 5.3
12 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 9.2 5.2
14 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 9.1 5.2
16 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 9.0 5.1
18 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 8.8 5.0
20 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 8.7 5.0
21 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 8.7 4.9
23 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 8.5 4.9
25 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 8.4 4.8
27 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 8.3 4.7
29 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 8.2 4.7
31 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 8.1 4.6
33 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 7.9 4.5
35 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 7.8 4.4
37 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 7.7 4.4
39 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 7.6 4.3
5.6
Indoor unit
Ceiling Cassette 1-way
1-10 1-10
C
a
s
s
e
t
t
e

1
-
w
a
y
6.2 Heating Capacity
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
2.2
-19.8 -20.0 1.7 1.7 1.7 1.7 1.7 1.7
-18.8 -19.0 1.7 1.7 1.7 1.7 1.7 1.7
-16.7 -17.0 1.8 1.8 1.8 1.8 1.8 1.8
-14.7 -15.0 1.9 1.9 1.7 1.9 1.9 1.9
-12.6 -13.0 2.0 2.0 1.8 2.0 2.0 2.0
-10.5 -11.0 2.1 2.1 1.9 2.1 2.1 2.1
-9.5 -10.0 2.2 2.2 1.9 2.2 2.2 2.1
-8.5 -9.1 2.2 2.2 2.0 2.2 2.2 2.1
-7.0 -7.6 2.3 2.3 2.0 2.2 2.2 2.2
-5.0 -5.6 2.4 2.4 2.1 2.3 2.3 2.2
-3.0 -3.7 2.5 2.5 2.2 2.4 2.4 2.2
0.0 -0.7 2.6 2.6 2.3 2.4 2.4 2.2
3.0 2.2 2.8 2.7 2.4 2.4 2.4 2.2
5.0 4.1 2.8 2.7 2.5 2.4 2.4 2.2
7.0 6.0 2.9 2.7 2.5 2.4 2.4 2.2
9.0 7.9 2.9 2.7 2.5 2.4 2.4 2.2
11.0 9.8 2.9 2.7 2.5 2.4 2.4 2.2
13.0 11.8 2.9 2.7 2.5 2.4 2.4 2.2
15.0 13.7 2.9 2.7 2.5 2.4 2.4 2.2
-19.8 -20.0 2.1 2.1 2.1 2.1 2.1 2.1
-18.8 -19.0 2.2 2.2 2.2 2.2 2.2 2.2
-16.7 -17.0 2.3 2.3 2.3 2.3 2.3 2.3
-14.7 -15.0 2.5 2.4 2.2 2.4 2.4 2.4
-12.6 -13.0 2.6 2.6 2.3 2.6 2.6 2.6
-10.5 -11.0 2.7 2.7 2.4 2.7 2.7 2.7
-9.5 -10.0 2.8 2.8 2.5 2.8 2.8 2.7
-8.5 -9.1 2.8 2.8 2.5 2.8 2.8 2.7
-7.0 -7.6 2.9 2.9 2.6 2.8 2.8 2.8
-5.0 -5.6 3.0 3.0 2.7 3.0 3.0 2.8
-3.0 -3.7 3.2 3.2 2.8 3.1 3.0 2.8
0.0 -0.7 3.4 3.4 3.0 3.1 3.0 2.8
3.0 2.2 3.6 3.4 3.1 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.7 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.7 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.7 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.7 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.7 3.4 3.2 3.1 3.0 2.8
-19.8 -20.0 2.7 2.7 2.7 2.6 2.6 2.6
-18.8 -19.0 2.8 2.8 2.8 2.8 2.7 2.7
-16.7 -17.0 2.9 2.9 2.9 2.9 2.9 2.9
-14.7 -15.0 3.1 3.0 2.7 3.0 3.0 3.0
-12.6 -13.0 3.2 3.2 2.9 3.2 3.2 3.2
-10.5 -11.0 3.4 3.4 3.0 3.4 3.4 3.4
-9.5 -10.0 3.4 3.4 3.1 3.4 3.4 3.4
-8.5 -9.1 3.5 3.5 3.2 3.5 3.5 3.4
-7.0 -7.6 3.6 3.6 3.3 3.6 3.6 3.5
-5.0 -5.6 3.8 3.8 3.4 3.7 3.7 3.5
-3.0 -3.7 4.0 4.0 3.5 3.9 3.8 3.5
0.0 -0.7 4.2 4.2 3.7 3.9 3.8 3.5
3.0 2.2 4.4 4.3 3.9 3.9 3.8 3.5
5.0 4.1 4.5 4.3 4.0 3.9 3.8 3.5
7.0 6.0 4.6 4.3 4.0 3.9 3.8 3.5
9.0 7.9 4.6 4.3 4.0 3.9 3.8 3.5
11.0 9.8 4.6 4.3 4.0 3.9 3.8 3.5
13.0 11.8 4.6 4.3 4.0 3.9 3.8 3.5
15.0 13.7 4.6 4.3 4.0 3.9 3.8 3.5
2.8
3.6
Notes:
TC: Total Capacity(kW)
Heating capacity
Indoor unit
Ceiling Cassette 1-way
1-11 1-11
C
a
s
s
e
t
t
e

1
-
w
a
y
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
5.6
-19.8 -20.0 4.2 4.2 4.2 4.2 4.2 4.2
-18.8 -19.0 4.3 4.3 4.3 4.3 4.3 4.3
-16.7 -17.0 4.6 4.6 4.6 4.6 4.6 4.5
-14.7 -15.0 4.9 4.8 4.3 4.8 4.8 4.8
-12.6 -13.0 5.1 5.1 4.5 5.0 5.0 5.0
-10.5 -11.0 5.4 5.4 4.8 5.4 5.3 5.3
-9.5 -10.0 5.4 5.4 4.9 5.4 5.4 5.4
-8.5 -9.1 5.5 5.5 5.0 5.5 5.5 5.4
-7.0 -7.6 5.7 5.7 5.1 5.6 5.6 5.5
-5.0 -5.6 6.0 6.0 5.4 5.8 5.8 5.5
-3.0 -3.7 6.2 6.2 5.5 6.1 5.9 5.5
0.0 -0.7 6.6 6.6 5.8 6.1 5.9 5.5
3.0 2.2 7.0 6.7 6.2 6.1 5.9 5.5
5.0 4.1 7.1 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.2 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.2 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.2 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.2 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.2 6.7 6.3 6.1 5.9 5.5
-19.8 -20.0 4.8 4.8 4.8 4.7 4.7 4.7
-18.8 -19.0 4.9 4.9 4.9 4.9 4.8 4.8
-16.7 -17.0 5.2 5.2 5.2 5.2 5.2 5.1
-14.7 -15.0 5.5 5.4 4.9 5.4 5.4 5.4
-12.6 -13.0 5.8 5.8 5.1 5.7 5.7 5.7
-10.5 -11.0 6.0 6.0 5.4 6.0 6.0 6.0
-9.5 -10.0 6.1 6.1 5.5 6.1 6.1 6.0
-8.5 -9.1 6.2 6.2 5.6 6.2 6.2 6.1
-7.0 -7.6 6.5 6.5 5.8 6.3 6.3 6.2
-5.0 -5.6 6.7 6.7 6.0 6.6 6.6 6.2
-3.0 -3.7 7.0 7.0 6.2 6.8 6.7 6.2
0.0 -0.7 7.5 7.5 6.6 6.9 6.7 6.2
3.0 2.2 7.9 7.6 6.9 6.9 6.7 6.2
5.0 4.1 8.0 7.6 7.1 6.9 6.7 6.2
7.0 6.0 8.2 7.6 7.1 6.9 6.7 6.2
9.0 7.9 8.2 7.6 7.1 6.9 6.7 6.2
11.0 9.8 8.2 7.6 7.1 6.9 6.7 6.2
13.0 11.8 8.2 7.6 7.1 6.9 6.7 6.2
15.0 13.7 8.2 7.6 7.1 6.9 6.7 6.2
7.1
Notes:
TC: Total Capacity(kW)
Heating capacity
Indoor unit
7. Air Velocity and Temperature Distribution(Reference Data)
Ceiling Cassette 1-way
1-12 1-12
C
a
s
s
e
t
t
e

1
-
w
a
y
1
4
1
6
2
0
2
2
2
4
2
4
2
4
2
4
2
6
26
26
2
6
2
6
2
8
2
8
28
28
2
8
28 2
8
2
8
3
0
30
3
0
3
0
30
3
0
3
0
32 32
3
2
0
0
1m
2m
Cooling Heating
Discharge angle: 50C
Air velocity [m/s]
Temperature [C]
Discharge angle: 60C
Air velocity [m/s]
Temperature [C]
0
.5
0.5
0
. 5
0
.5
0
.5
0
.5
0.5
0
.5
0
.5
0
.5
0
.5
1
1
1
1
1
1
1
.5
1
.5
1.5
2
2
.5
3
0
0 1m 2m 3m 4m 5m
1m 2m 3m 4m 5m
1m
2m
3
1
3
1
3
1
3
1
3
1
3
2
3
2
32
3
2
3
3
3
3
3
4
3
4
34
34
3
4
3
5
3
5
35
35
3
5
3
6
3
6
36
3
6
3
6
3
6
3
7
3
7
3
7
3
8
3
9
4
1
4
2
0
0 1m 2m 3m 4m 5m
1m
2m
0
.1
0.1
0
.1
0.1
0.1
0 1
0
.1
0
.1
0.1
0
.1
0.1
0
.5
0.5
0
5
0
. 5
0
.5
0
. 5
0
.5
0
.5
0.5
0
.5
1
.0
1
. 0
1
.0
1
.0
1
.0
1
.5
2
.0
2
.5
3
.0
3
.5
4
.5
0
0 1m 2m 3m 4m 5m
1m
2m
Air velocity [m/s]
Temperature [C]
Air velocity [m/s]
Temperature [C]
1
8 2
0
2
2
2
2
2
4
2
4
2
4
2
4
2
6
26
26 26
2
6
2
8
2
8
28
28
2
8
28 28
2
8
30
3
0
3
0
30
3
0
30
32 32
3
2
0
.5
0
.5
0.5
0
.5
0
.5
0
.5
0.5
0
. 5
0
.5
0
.5
1
1
1
1
1
1
1
.5
1
.5
1
.5
2
2
.5
2
.5
3
3
.5
0.1 0.1
0
.1
0
.1
0 1
0
1
0
. 1
0
.1
0
.5
0.5
0
.5
0
.5
0.5 0.5
0
. 5
0
.5
1
.0
1.0
1
.0 1
.0
1
. 0
1
.5
1
.5
1
.5
1
.5
2
.0
3
.0
3
1
3
1
31
3
1
32
3
2
32
3
2
32 32
3
3
3
3
3
3
3
3
3
4
3
4
3
4
34
3
4
3
5
3
5
35
3
5
3
5
3
6
3
6
36
3
6 3
6
36
36
3
7
3
7
3
8
3
83
9
4
2
0
0
1m
2m
Cooling Heating
Discharge angle: 50C Discharge angle: 60C
0
0 1m 2m 3m 4m 5m
1m 2m 3m 4m 5m
1m
2m
0
0 1m 2m 3m 4m 5m
1m
2m
0
0 1m 2m 3m 4m 5m
1m
2m
Note:
The standard setup height is 2.7m. Shown here is the measurement distribution at the ceiling height of 2.7m
ARNU07GTU*2
ARNU09GTU*2
Indoor unit
Ceiling Cassette 1-way
1-13 1-13
C
a
s
s
e
t
t
e

1
-
w
a
y
Note:
The standard setup height is 2.7m. Shown here is the measurement distribution at the ceiling height of 2.7m
0
.5
0.5
0
.5
0
.5
0
.5
0
.5
0.5 0.5
0
. 5
0
. 5
1
1
1
1
1
1
1
.5
1
. 5
1
.5
1.5
1
.5 2
2
2
.5
2
2
2
4
24
2
4
2
6
2
6
26 26
2
6
26
2
8
28
2
8
2
8
28
28
2
8
2
8
3
0
30
3
0
30
3
0
32 32
Air velocity [m/s]
Temperature [C]
Air velocity [m/s]
Temperature [C]
31
3
1
31
3
1
32
3
2
32
3
2
32 32
3
3
33
3
3
3
4
3
4
3
4
34
3
4
3
5
35
35
3
5
3
6
3
6
36
3
6
36
3
6
3
7
3
7
37
3
7
3
8
3
9
4
0
4
1
0
.1 0.1
0
.1
0 1
0
.1
0
.1
0
.1
0
.1
0
.5
0.5
0
.5
0
.5
0
.5
0
.5
0
5
0
5
0
.5
0
.5
0
.5
1
.0
1.0
1
.0
1
.0
1.0
1
. 0
1
. 0
1.0
1
.5
1
.5
1
.5
1
.5
2
.0
2
.0
2
.5
4
.0
0
0
1m
2m
Cooling Heating
Discharge angle: 50C Discharge angle: 60C
0
0 1m 2m 3m 4m 5m
1m 2m 3m 4m 5m
1m
2m
0
0 1m 2m 3m 4m 5m
1m
2m
0
0 1m 2m 3m 4m 5m
1m
2m
Air velocity [m/s]
Temperature [C]
Air velocity [m/s]
1
8
2
0
2
2
2
2
2
4
24
2
4
2
4
2
6
26
26
2
6
2
8
2
8
2
8
28
2
8
28
2
8
3
0
30
3
0
3
0
3
0
32 32
3
2
Temperature [C]
0
.5
0.5
0.5
0
.5
0
.5
0
.5
0.5
.5
0
. 5
0
.5
0
. 5
1
1
1
1
1
1
1
1
.5
1
.5
1
.5
2
2
2
.5
3
.5
4
.5
5
31
3
1
31
3
1
3
2
32
3
2
32 32
3
3
33
3
3
3
3
3
4
3
4
34
3
4
3
4
3
5
3
5
3
5
3
6
3
6
3
6
3
6
3
6 3
7
3
8
3
94
0
4
1
0
.5
0
.5
0.5
0.5
0.5
0
.5
0.5
0
.5
0
.5
0
.5
1
1
1
1
1
1
.5
1
.5
1
.5
1
.5
2
2
2
.5
3 4
0
0
1m
2m
Cooling Heating
Discharge angle: 50C Discharge angle: 60C
0
0 1m 2m 3m 4m 5m
1m 2m 3m 4m 5m
1m
2m
0
0 1m 2m 3m 4m 5m
1m
2m
0
0 1m 2m 3m 4m 5m
1m
2m
ARNU12GTU*2
ARNU18GTT*2
Indoor unit
Ceiling Cassette 1-way
1-14 1-14
C
a
s
s
e
t
t
e

1
-
w
a
y
Note:
The standard setup height is 2.7m. Shown here is the measurement distribution at the ceiling height of 2.7m
Air velocity [m/s]
Temperature [C]
Air velocity [m/s]
Temperature [C]
1
2
1
6
2
0
2
2
2
2
2
4
2
4
4
2
4
2
4
2
6
2
6
2
6
2
8
2
8
2
8
28
2
8
28
2
8
2
8
30
30
3
0
3
0
3
0
3
0
32 32
0
.5
0.5
0
.5
0
.5
0
.5
0
.5
0.5 0.5
0
.5
0
.5
0
.5
1
1
1
1
1
1
1
1
1
.5
1
.5
1
.5
1
.5
1
.5
2
2
2
2
.5
3.5
4
.5
3
1
3
1
3
1
3
1
3
2 32
3
2
32 32
3
3
3
3
3
3
3
3
3
4
3
4
34
3
4
3
5
3
5
3
5 3
6
3
6
3
6
3
6
3
6
3
7
3
7
3
8
3
9
4
0
0
.5
0
.5
0
.5
0
.5
0
.5
0
5
0
.5
0
.5
1
1
1
1
1
1
1
1
1
.5
1
.5
1.5
1
.5
2
2
2
.5
3
0
0
1m
2m
Cooling Heating
Discharge angle: 50C Discharge angle: 60C
0
0 1m 2m 3m 4m 5m
1m 2m 3m 4m 5m
1m
2m
0
0 1m 2m 3m 4m 5m
1m
2m
0
0 1m 2m 3m 4m 5m
1m
2m
ARNU24GTT*2
Indoor unit
8. Electric Characteristics
Ceiling Cassette 1-way
1-15 1-15
C
a
s
s
e
t
t
e

1
-
w
a
y
Units
Model Type Hz Volts Voltage Range
ARNU07GTU*2 TU
ARNU09GTU*2 TU
Max:264
ARNU12GTU*2 TU 50 220-240
Min:198
ARNU18GTT*2 TT
ARNU24GTT*2 TT
1.23 15 0.03 0.18 40 40
1.23 15 0.03 0.18 40 40
1.23 15 0.03 0.18 40 40
1.38 15 0.03 0.30 70 70
1.38 15 0.03 0.30 70 70
1.23 15 0.03 0.18 40 40
1.23 15 0.03 0.18 40 40
1.23 15 0.03 0.18 40 40
1.38 15 0.03 0.30 70 70
1.38 15 0.03 0.30 70 70
ARNU07GTU*2 TU
ARNU09GTU*2 TU
Max:242
ARNU12GTU*2 TU 60 220
Min:198
ARNU18GTT*2 TT
ARNU24GTT*2 TT
Power Supply IFM Input(W)
MCA MFA kW FLA Cooling Heating
Symbols:
MCA : Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor
Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA + 1
MFA 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the larger value on the MCA.
5. Instead of fuse, use Circuit Breaker.
Indoor unit
9. Sound Levels
Ceiling Cassette 1-way
1-16 1-16
C
a
s
s
e
t
t
e

1
-
w
a
y
Overall
Sound Pressure Level
ARNU07GTU*2 ARNU09GTU*2 ARNU12GTU*2
Notes:
- Sound measured at 1.5m away from the center of the unit.
- Data is valid at free field condition
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.
1.5m
Microphone
Model
ARNU07GTU*2
ARNU09GTU*2
ARNU12GTU*2
ARNU18GTT*2
ARNU24GTT*2
Sound Levels dB(A)
H M L
32
35
38
40
43
29
34
35
37
40
25
32
32
35
36
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
Indoor unit
Ceiling Cassette 1-way
1-17 1-17
C
a
s
s
e
t
t
e

1
-
w
a
y
ARNU18GTT*2 ARNU24GTT*2
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0
P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0
P
a

)
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
Indoor unit
10. Installation
Ceiling Cassette 1-way
1-18 1-18
C
a
s
s
e
t
t
e

1
-
w
a
y
Please read this instruction sheet completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
Remote Controller
TEMP
Wired remote
controller
Inlet
Outlet
Required Parts Required Tools
Connecting cable
Pipes: Gas side
Liquid side
Hanging Bolt
(W 3/8 or M10 length 650mm)
Insulated drain hose
Additional Drain hose
Level
Screw driver
Electric drill
Hole core drill
Flaring Tool set
Torque Wrenches
Hexagonal Wrench
Gas-leak detector
Thermometer
10.1 Selection of the best location
There should not be any heat source or steam near the
unit.
There should not be any obstacles to the air circula-
tion.
A place where air circulation in the room will be good.
A place where drainage can be easily obtained.
A place where noise prevention is taken into consider-
ation.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall,
ceiling, or other obstacles.
The indoor unit must have the maintenance space.
Unit:mm
Ceiling
Ceiling board
Ceiling board
2
0
0

o
r

m
o
r
e
A
b
o
v
e

2
5
0
0
3
3
0
0

o
r

l
e
s
s
1
0
0
0

o
r

m
o
r
e
500 or
more
500 or
more 3
0
0

o
r

l
e
s
s
Floor
Indoor unit
Ceiling Cassette 1-way
1-19 1-19
C
a
s
s
e
t
t
e

1
-
w
a
y
10.2 Ceiling opening dimensions and hanging bolt location
NOTE:
Avoid the following installation location.
1. Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated.
These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function.
In these cases, take the following actions;
Make sure that ventilation fan is enough to cover all noxious gases from this place.
Ensure enough distance from the cooking room to install the air conditioner in such a place where it may
not suck oily steam.
Level gauge
Ceiling
Use the ventilation fan
for smoke-collecting
hood with sufficient
capacity.
Cooking table
Air conditioner
Take enough
distance
(unit: mm)
TT Chassis
TU Chassis
1,285
1,385
50
250
600 50

4
6
6

1,180
4
4
8
600
250
965
1,065
50 50
4
6
6
860
4
4
8
3
0
6
4
0
0
4
0
4
0
4
0
0
4
0
4
0
3
0
6
3
5
4
3
5
4
Ceiling board
The dimensions of the paper model for installation
are the same as those of the ceiling opening dimen-
sions.
Select and mark the position for fixing bolts and pip-
ing hole.
Decide the position for fixing bolts slightly tilted to
the drain direction after considering the direction of
drain hose.
Drill the hole for anchor bolt on the wall.
This air-conditioner uses a drain pump.
Install the unit horizontally using a level gauge.
During the installation, care should be taken not to
damage electric wires.
CAUTION
2. Avoid installing air conditioner in such places where cooking oil or iron powder is generated.
3. Avoid places where inflammable gas is generated.
4. Avoid place where noxious gas is generated.
5. Avoid places near high frequency generators.
Indoor unit
Ceiling Cassette 1-way
1-20 1-20
C
a
s
s
e
t
t
e

1
-
w
a
y
Set screw of
paper model (4 pieces)
Paper model
for installation
Ceiling board
7
0
m
m
Adjust the same height
Ceiling board
Ceiling
Flat washer for M10
(accessory)
Keep the length of the bolt
from the bracket to 40mm
Open the ceiling board
along the outer edge of the
paper model
Flat washer for M10
(accessory)
Hanging bolt
(W3/8 or M10)
Nut
(W3/8 or M10)
Nut
(W3/8 or M10)
Spring washer
(M10)
Air conditioner body
The following parts are local purchasing.
Hanging bolt - W 3/8 or M10
Nut - W 3/8 or M10
Spring washer - M10
Plate washer - M10
Tighten the nut and bolt to prevent the unit
from falling.
CAUTION
Terminal block of indoor unit
Terminal block of outdoor unit
1(L) 2(N) 3 4
Indoor power input
IDU IDU
Outdoor unit Indoor unit
Central controller
SODU SODU DRY1 DRY2 GND INTERNET 12V
10.3 Wiring Connection
Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit
respectively.
Make sure that the screws of the terminal are not loose.
WARNING
Indoor unit
Ceiling Cassette 1-way
1-21 1-21
C
a
s
s
e
t
t
e

1
-
w
a
y
10.4 Installation of Decoration Panel
1. Open the air outlet vane, and extract side covers.
2. Remove the air inlet grille from the decoration panel.
3. Hook decoration panel to indoor unit, using hooks attached at the backside of both side of decoration
panel.
4. Arrange wires not to get caught between decoration panel and indoor unit.
5. Screw 7 fixing screws. (7,9,12kBtu : 6 screws)
6. Connect the vane motor connector and display connector. (Plasma connector for plasma model)
7. Install the air inlet grille (including the air filter) and side covers.
Air conditioner unit
Decorative panel
Plasma filter
(applied only to plasma model)
Mesh
Control box cover
Decorative panel
fixing screws
(hexagon M6 screws)
(tightening about 20mm)
Side cover
Air inlet grille
Air inlet grille
The decoration panel has its installation
direction.
Before installing the decoration panel,
always remove the paper template.
CAUTION
Install certainly the
decoration panel.
Cool air leakage caus-
es sweating.
Waterdrops fall.
Cool air leakage
(no good)
Decorative panel
Air conditioner
unit
Ceiling
board
Fit the insulator (this part) and
be careful for cool air leakage
Decorative panel
Air conditioner
unit
Ceiling
board
Good example Bad example
Indoor unit
Ceiling Cassette 1-way
1-22 1-22
C
a
s
s
e
t
t
e

1
-
w
a
y
10.5 Indoor Unit Drain Piping
Drain piping must have down-slope (1/50 to 1/100): be sure
not to provide up-and-down slope to prevent reversal flow.
During drain piping connection, be careful not to exert extra
force on the drain port on the indoor unit.
The outside diameter of the drain connection on the indoor
unit is 32mm.
Be sure to install heat insulation on the drain piping.
Piping material: Polyvinyl chloride pipe 25mm
and pipe fittings
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:
Connect the main drain pipe to the exterior
and leave it provisionally until the test comes
to an end.
Feed water to the flexible drain hose and
check the piping for leakage.
Be sure to check the drain pump for normal
operating and noise when electrical wiring is
complete.
When the test is complete, connect the flexi-
ble drain hose to the drain port on the indoor
unit.
Heat insulation material: Polyethylene foam with
thickness more than 8 mm.
Drain test
Feed water
Drain pump
Drain pan
Flexible drain hose
(accessory)
Main
drain pipe
Glue the joint
Drain
port
Drain hose connection
Use the clip (accessory)
Maintenance
drain port
Upward
routing
not allowed
Pipe clamp
Indoor unit
1/50~1/100
Max 700mm
1/50~1/100 slope
Hanger
distance
Hanger bracket
M
a
x

7
0
0
m
m
Flexible drain hose
Insulation
Metal
clamp
Max 300mm
1~15m
CAUTION
The supplied flexible drain hose should not be curved,
neither screwed. The curved or screwed hose may
cause a leakage of water.
Indoor unit
Ceiling Cassette 1-way
1-23 1-23
C
a
s
s
e
t
t
e

1
-
w
a
y
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have separate power specially for the air conditioner. As for the method of wiring, follow the circuit
diagram pasted on the inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to
which the unit is subjected during the course of transportation. Check them and make sure that they are all
tightly fastened. (If they are loose, it could give rise to burn-out of the wires.)
4) Confirm the Specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name
plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Do not install the leakage breaker in a place which is wet or moist.
Water or moist may cause short circuit.
9) The following troubles would be caused by voltage drop-down.
Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the normal function of
a overload protection device.
Proper starting power is not given to the compressor.
CAUTION
WIRED REMOTE CONTROLLER INSTALLATION
Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place away
from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
Fig.1 Typical locations for remote controller
5feet
(1.5meters)
no
no
no
yes
Remote Controller
TEMP
Remote Controller
TEMP
Remote Controller
TEMP
Indoor unit
11. Accessories
Ceiling Cassette 1-way
1-24 1-24
C
a
s
s
e
t
t
e

1
-
w
a
y
Name
Quantity
Shape
for gas pipe
for liquid pipe
Clamp metal
2 EA
Insulation for
fitting
1 SET
Drain hose
1 EA
Plastic band
8 EA
Washer for
hanging bracket
4 EA
Name
Quantity
Shape
Paper pattern for installation
1EA
Installation and Owner's manual
1EA
Use only those accessories (Standard or optional) which have designated specifications.
CAUTION
Indoor unit
Ceiling Cassette 2-way
C
a
s
s
e
t
t
e

2
-
w
a
y
1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. Air Velocity and Temperature Distribution
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories
Ceiling Cassette 2-Way
Indoor unit
Ceiling Cassette 2-way
2-1 2-1
C
a
s
s
e
t
t
e

2
-
w
a
y
1. List of functions
O : Applied X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Air flow
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Air purifying Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
Installation
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Reliability Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Convenience Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Individual Simple wired remote controller
control Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Special
Zone control
function kit
CTIE
Electro thermostat
2
-
Auto
-
O
4 / 5 / 4
X
O
O
-
X
Option
O
O
O
X
O
O
O
O
O(Heat recovery)
X
O(Heat pump or Cooling only)
O
O
O
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
X
Accessory
-
-
-
Function Category ARNU18GTL*2, ARNU24GTL*2
Indoor unit
Ceiling Cassette 2-way
2-2 2-2
C
a
s
s
e
t
t
e

2
-
w
a
y
2. Specifications
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Body
mm
Dimensions (WxDxH)
inch
Front Panel
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Fan Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight Body kg(lbs)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable
Transmission cable
Panel Color
Panel Name(Accessory)
2Way Ceiling Cassette
ARNU18GTL*2
5.6
4,800
19,100
6.3
5,400
21,500
Galvanized Steel Plate
830 x 550 x 225
32.6 x 21.6 x 8.9
1,050 x 640 x 28.5
41.3 x 25.2 x 1.1
2 x 11 x 20
0.13
Cross Flow Fan
20 x 2
0.18 x 2
13 / 12 / 10
459 / 424 / 353
Direct
BLDC
Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Fuse
6.35(1/4)
12.7(1/2)
25(1)
22(48.5)
40 / 35 / 30
1, 220-240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C
Morning fog
PT-HL*
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are Net Capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
* Model Name
A:Basic, C:Plasma
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Indoor unit
Ceiling Cassette 2-way
2-3 2-3
C
a
s
s
e
t
t
e

2
-
w
a
y
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Body
mm
Dimensions (WxDxH)
inch
Front Panel
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Fan Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight Body kg(lbs)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable
Transmission cable
Panel Color
Panel Name(Accessory)
2Way Ceiling Cassette
ARNU24GTL*2
7.1
6,100
24,200
8.0
6,900
27,300
Galvanized Steel Plate
830 x 550 x 225
32.6 x 21.6 x 8.9
1,050 x 640 x 28.5
41.3 x 25.2 x 1.1
2 x 11 x 20
0.13
Cross Flow Fan
20 x 2
0.18 x 2
17 / 15 / 13
601 / 530 / 459
Direct
BLDC
Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Fuse
9.52(3/8)
15.88(5/8)
25(1)
22(48.5)
42 / 37 / 32
1, 220-240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C
Morning fog
PT-HL*
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are Net Capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
* Model Name
A:Basic, C:Plasma
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Indoor unit
Ceiling Cassette 2-way
2-4 2-4
C
a
s
s
e
t
t
e

2
-
w
a
y
3. Dimensions
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

T
L
C
e
i
l
i
n
g

C
a
s
s
e
t
t
e

2
-
w
a
y
A
R
N
U
1
8
G
T
L
*
2





A
R
N
U
2
4
G
T
L
*
2
N
a
m
e
1
L
i
q
u
i
d

p
i
p
e

c
o
n
n
e
c
t
i
o
n
U
n
i
t

s
i
z
e
(
1
8
k
)
:

6
.
3
5
U
n
i
t

s
i
z
e
(
2
4
k
)
:

9
.
5
2
2
G
a
s

p
i
p
e

c
o
n
n
e
c
t
i
o
n
U
n
i
t

s
i
z
e
(
1
8
k
)
:

1
2
.
7
U
n
i
t

s
i
z
e
(
2
4
k
)
:

1
5
.
8
8

3
A
i
r

s
u
c
t
i
o
n

g
r
i
l
l


4
A
i
r

d
i
s
c
h
a
r
g
e

g
r
i
l
l

N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
(
u
n
i
t

:

m
m
)
3
5
.
6
9
3
1
.
2
9
2
6
.
5
1
7
7
.
1
2
2
5
8
9
3
3 4
2 0 6 . 56 9 . 2
2 0 5 . 56 9 . 2
4 8 2
5 5 0
1 6 2 . 4
1 4 4 . 2
8
3
0
2
1
4
3
Indoor unit
Ceiling Cassette 2-way
2-5 2-5
C
a
s
s
e
t
t
e

2
-
w
a
y
4. Piping Diagrams
Heat Exchanger
C.F.F.
lndoor unit
EEV
Filter
Filter
Th3
Th1
Th2
:Heating
:Cooling
Refrigerant pipe connection port diameter
Model
ARNU18GTL*2
ARNU24GTL*2
Gas
12.7(1/2)
15.88(5/8)
Liquid
6.35(1/4)
9.52(3/8)
[Unit: mm(inch)]
LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor
Indoor unit
Ceiling Cassette 2-way
2-6 2-6
C
a
s
s
e
t
t
e

2
-
w
a
y
5. Wiring Diagrams
CONNECTOR NUMBER SPEC DESCRIPTION
CN-POWER AC Power supply AC Power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC output for drain pump
CN-485 Communication Connection between indoor and outdoor
CN-DISP Display Display of indoor status
CN-EEV EEV Output EEV Control output
CN-VANE2 Step motor Step motor output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room air thermistor
CN-REMO Remote controller Remote control line
TL Chassis
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor
CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.
Indoor unit
Ceiling Cassette 2-way
2-7 2-7
C
a
s
s
e
t
t
e

2
-
w
a
y
6. Capacity Tables
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.4 4.2
12 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.3 4.1
14 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.2 4.1
16 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.1 4.0
18 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.0 4.0
20 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.9 3.9
21 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.8 3.9
23 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.7 3.8
25 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.6 4.2 6.6 3.8
27 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.4 4.1 6.6 3.7
29 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.4 4.0 6.5 3.7
31 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.3 3.9 6.4 3.6
33 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.2 3.9 6.3 3.6
35 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.0 3.8 6.2 3.5
37 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 5.8 3.9 5.9 3.7 6.1 3.5
39 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 5.7 3.9 5.8 3.7 6.0 3.4
5.6
6.1 Cooling Capacity
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
Cooling capacity
Indoor unit
Ceiling Cassette 2-way
2-8 2-8
C
a
s
s
e
t
t
e

2
-
w
a
y
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
7.1
10 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 9.3 5.3
12 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 9.2 5.2
14 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 9.1 5.2
16 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 9.0 5.1
18 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 8.8 5.0
20 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 8.7 5.0
21 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 8.7 4.9
23 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 8.5 4.9
25 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.4 5.3 8.4 4.8
27 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.2 5.1 8.3 4.7
29 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.1 5.1 8.2 4.7
31 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.0 5.0 8.1 4.6
33 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 7.8 4.9 7.9 4.5
35 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 7.7 4.8 7.8 4.4
37 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.4 5.0 7.5 4.7 7.7 4.4
39 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.2 4.9 7.4 4.6 7.6 4.3
Cooling capacity
Indoor unit
Ceiling Cassette 2-way
2-9 2-9
C
a
s
s
e
t
t
e

2
-
w
a
y
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 4.2 4.2 4.2 4.2 4.2 4.2
-18.8 -19.0 4.3 4.3 4.3 4.3 4.3 4.3
-16.7 -17.0 4.6 4.6 4.6 4.6 4.6 4.5
-14.7 -15.0 4.9 4.8 4.3 4.8 4.8 4.8
-12.6 -13.0 5.1 5.1 4.5 5.0 5.0 5.0
-10.5 -11.0 5.4 5.4 4.8 5.4 5.3 5.3
-9.5 -10.0 5.4 5.4 4.9 5.4 5.4 5.4
-8.5 -9.1 5.5 5.5 5.0 5.5 5.5 5.4
-7.0 -7.6 5.7 5.7 5.1 5.6 5.6 5.5
-5.0 -5.6 6.0 6.0 5.4 5.8 5.8 5.5
-3.0 -3.7 6.2 6.2 5.5 6.1 5.9 5.5
0.0 -0.7 6.6 6.6 5.8 6.1 5.9 5.5
3.0 2.2 7.0 6.7 6.2 6.1 5.9 5.5
5.0 4.1 7.1 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.2 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.2 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.2 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.2 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.2 6.7 6.3 6.1 5.9 5.5
5.6
6.2 Heating Capacity
Notes:
TC: Total Capacity(kW)
Heating capacity
Indoor unit
Ceiling Cassette 2-way
2-10 2-10
C
a
s
s
e
t
t
e

2
-
w
a
y
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 5.4 5.4 5.4 5.3 5.3 5.3
-18.8 -19.0 5.5 5.5 5.5 5.5 5.4 5.4
-16.7 -17.0 5.8 5.8 5.8 5.8 5.8 5.8
-14.7 -15.0 6.2 6.1 5.5 6.1 6.1 6.1
-12.6 -13.0 6.5 6.5 5.8 6.4 6.4 6.4
-10.5 -11.0 6.8 6.8 6.0 6.8 6.7 6.7
-9.5 -10.0 6.9 6.9 6.2 6.9 6.9 6.8
-8.5 -9.1 7.0 7.0 6.3 7.0 7.0 6.8
-7.0 -7.6 7.3 7.3 6.5 7.1 7.1 7.0
-5.0 -5.6 7.6 7.6 6.8 7.4 7.4 7.0
-3.0 -3.7 7.9 7.9 7.0 7.7 7.5 7.0
0.0 -0.7 8.4 8.4 7.4 7.8 7.5 7.0
3.0 2.2 8.9 8.6 7.8 7.8 7.5 7.0
5.0 4.1 9.0 8.6 8.0 7.8 7.5 7.0
7.0 6.0 9.2 8.6 8.0 7.8 7.5 7.0
9.0 7.9 9.2 8.6 8.0 7.8 7.5 7.0
11.0 9.8 9.2 8.6 8.0 7.8 7.5 7.0
13.0 11.8 9.2 8.6 8.0 7.8 7.5 7.0
15.0 13.7 9.2 8.6 8.0 7.8 7.5 7.0
7.1
Heating capacity
Notes:
TC: Total Capacity(kW)
Indoor unit
Ceiling Cassette 2-way
2-11 2-11
C
a
s
s
e
t
t
e

2
-
w
a
y
7. Air Velocity and Temperature Distribution(Reference Data)
Air velocity [m/s]
Temperature [C]
Discharge angle: 40
Air velocity [m/s]
Temperature [C]
Discharge angle: 60
2.7m
2m
1m
0m
4m 3m 2m 1m 0m 1m 2m 3m 4m
3.0 3.0
2.5 2.5
2.0 2.0
1.5 1.5
1.0 1.0
0.5 0.5
2.7m
2m
1m
0m
4m 3m 2m 1m 0m 1m 2m 3m 4m
2.5 2.5
2.0 2.0
1.5 1.5
1.0 1.0
0.5 0.5
2.7m
2m
1m
0m
4m 3m 2m 1m 0m 1m 2m 3m 4m
32 32
31 31
30 30
29 29
28 28
28 28
27 27 26 26
27
2.7m
2m
1m
0m
4m 3m 2m 1m 0m 1m 2m 3m 4m
20 20
21 21
22 22
23 23
24 24
ARNU24GTL*2
Cooling Heating
Indoor unit
Ceiling Cassette 2-way
2-12 2-12
C
a
s
s
e
t
t
e

2
-
w
a
y
8. Electric Characteristics
Units
Model Type Hz Volts Voltage Range
ARNU18GTL*2 TL
50 220-240
Max:264 0.52 15 0.04 0.41 70 70
ARNU24GTL*2 TL Min:198 0.52 15 0.04 0.41 70 70
ARNU18GTL*2 TL
60 220
Max:242 0.52 15 0.04 0.41 70 70
ARNU24GTL*2 TL Min:198 0.52 15 0.04 0.41 70 70
Power Supply IFM Input(W)
MCA MFA kW FLA Cooling Heating
Symbols:
MCA : Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor
Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA
MFA 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the larger value on the MCA.
5. Instead of fuse, use Circuit Breaker.
Indoor unit
Ceiling Cassette 2-way
2-13 2-13
C
a
s
s
e
t
t
e

2
-
w
a
y
9. Sound Levels
Overall
Sound Pressure Level
ARNU18GTL*2 ARNU24GTL*2
Notes:
- Sound measured at 1.5m away from the center of the unit.
- Data is valid at free field condition
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.
1.5m
Microphone
Model
ARNU18GTL*2
ARNU24GTL*2
Sound Levels dB(A)
H M L
40
42
35
37
30
32
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold 10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
Indoor unit
Ceiling Cassette 2-way
2-14 2-14
C
a
s
s
e
t
t
e

2
-
w
a
y
10. Installation
Please read the instruction sheets completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
Anti-bacteria filter
Air Outlet
Air Intake
Remote Controller
TEMP
Required Parts Required Tools
Connecting cable
Pipes: Gas side
Liquid side
Hanging Bolt
(W 3/8 or M10 length 650mm)
Insulated drain hose
Additional Drain hose
Level
Screw driver
Electric drill
Hole core drill
Flaring Tool set
Torque Wrenches
Hexagonal Wrench
Gas-leak detector
Thermometer
10.1 Selection of the best location
There should not be any heat source or steam near the
unit.
There should not be any obstacles to the air circula-
tion.
A place where air circulation in the room will be good.
A place where drainage can be easily obtained.
A place where noise prevention is taken into consider-
ation.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall,
ceiling, or other obstacles.
The indoor unit must have sufficient maintenance
space.
Unit:cm
Ceiling
Ceiling Board
Ceiling Board
2
0

o
r

m
o
r
e
A
b
o
v
e

2
0
0
3
0
0

o
r

l
e
s
s
1
0
0

o
r

m
o
r
e
50 or
more
50 or
more 3
0

o
r

l
e
s
s
Floor
Indoor unit
Ceiling Cassette 2-way
2-15 2-15
C
a
s
s
e
t
t
e

2
-
w
a
y
10.2 Ceiling opening dimensions and hanging bolt location
NOTE:
Avoid the following installation location.
1. Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated.
These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function.
In these cases, take the following actions;
Make sure that ventilation fan is enough to cover all noxious gases from this place.
Ensure enough distance from the cooking room to install the air conditioner in such a place where it may
not suck oily steam.
Ceiling board
Level gauge
Ceiling
Use the ventilation fan
for smoke-collecting
hood with sufficient
capacity.
Cooking table
Air conditioner
Take enough
distance
The dimensions of the paper pattern for installation
are the same as those of the ceiling opening
dimensions.
Select and mark the position for fixing bolts and
piping hole.
Decide the position for fixing bolts slightly tilted
to the drain direction after considering the direc-
tion of drain hose.
Drill the hole for anchor bolt on the wall.
This air-conditioner uses a drain pump.
Install the unit horizontally using a level gauge.
During the installation, care should be taken not to
damage electric wires.
CAUTION
2. Avoid installng air conditioner in such places where cooking oil or iron powder is generated.
3. Avoid places where inflammable gas is generated.
4. Avoid place where noxious gas is generated.
5. Avoid places near high frequency generators.
Indoor unit
Ceiling Cassette 2-way
2-16 2-16
C
a
s
s
e
t
t
e

2
-
w
a
y
Set screw of
paper pattern (4 pieces)
Paper pattern
for installation
False ceiling board
9
0
m
m
Adjust the same height
False
ceiling board
Ceiling
Flat washer for M10
(accessory)
Keep the length of the bolt
from the bracket to 40mm
Open the ceiling board
along the outer edge of the
paper pattern
Flat washer for M10
(accessory)
Hanging bolt
(W3/8 or M10)
Nut
(W3/8 or M10)
Nut
(W3/8 or M10)
Air Conditioner body
The following parts are locally purchased.
Hanging Bolt - W 3/8 or M10
Nut - W 3/8 or M10
Spring Washer - M10
Plate Washer - M10
Tighten the nut and bolt to prevent the unit
from falling.
CAUTION
Terminal Block Indoor
1(L) 2(N) 3 4
INDOOR POWER INPUT
A - - - - - - B A B
GND 12V DRY2 DRY1 INTERNET IDU SODU Outdoor
Unit
10.3 Wiring Connection
Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit
respectively.
Make sure that the screws of the terminal are not loose.
WARNING
Indoor unit
Ceiling Cassette 2-way
2-17 2-17
C
a
s
s
e
t
t
e

2
-
w
a
y
10.4 Installation of Decoration Panel
1. Temporarily fix two decoration panel fixing screws (hexagon M5 screw) on the unit body. (Tighten by amount 10mm in
length.)
The fixing screws (hexagon M5 screw) are included in the indoor unit box.
2. Remove the air inlet grille from the decoration panel. (Remove the hook for the air inlet grille cord.)
3. Hook the decoration panel key hole ( ) on the screws fixed in step above, and slide the panel so that the screws
reach the key hole edge.
4. Retighten completely two temporarily fixed screws and other two screws. (Total 4 screws)
5. Connect the louver motor connector and display connector.
6. After tightening these screws, install the air inlet grille
(including the air filter).
Piping side
Air conditioner unit
Decorative panel
Push
Decorative panel
fixing screws
(hexagon M6 screws)
Temporary fitting
at 2 poles
(Tightening about 10mm)
Control box cover
Cover
Plasma filter
Key holes
Decorative panel
fixing screws
(Hexagon M6 screw)
Louver motor
Ratch
pull
Inlet Grille
The decoration panel has its installation
direction.
Before installing the decoration panel,
always remove the paper template.
CAUTION
Install the decoration panel
otherwise cool air leakage
causes condensation.
Water drops fall.
Cool air leakage
(no good)
Decoration panel
Air conditioner
unit
Ceiling
board
Fit the insulator (this part) and
be careful for cool air leakage
Decoration panel
Air conditioner
unit
Ceiling
board
Correct method Wrong method
Indoor unit
Ceiling Cassette 2-way
2-18 2-18
C
a
s
s
e
t
t
e

2
-
w
a
y
10.5 Indoor Unit Drain Piping
Drain piping must have down-slope (1/50 to 1/100): Make sure
not to provide up-and-down slope to prevent reversal flow.
During drain piping connection, be careful not to exert extra
force on the drain port on the indoor unit.
The outside diameter of the drain connection on the indoor
unit is 32mm.
Make sure to install heat insulation on the drain piping.
Piping material: Polyvinyl chloride pipe inner
diometes 25mm and pipe fittings
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:
Connect the main drain pipe to the exterior and leave it
provisionally until the test comes to an end.
Feed water to the flexible drain hose and check the pip-
ing for leakage.
Make sure to check the drain pump for normal operating
and noise when electrical wiring is complete.
When the test is complete, connect the flexible drain
hose to the drain port on the indoor unit.
Heat insulation material: Polyethylene foam with
thickness more than 8 mm.
Drain test
Maintenance
drain port
Upward
routing
not allowed
Pipe clamp
Indoor unit
1/50~1/100
MAX 700mm
Feed water
Drain Pump
Drain pan
Flexible drain hose
(accessory)
Main
drain pipe
Glue the joint
Drain
port
Drain hose connection
Use the clip (accessory)
1/50~1/100 slope
Hanger
distance
Hanger Bracket
M
a
x

7
0
0
m
m
Flexible drain hose
Insulation
Metal
clamp
Max 300mm
1~15m
CAUTION
The supplied flexible drain hose should not be strained.
A strained hose may cause leakage of water.
Indoor unit
Ceiling Cassette 2-way
2-19 2-19
C
a
s
s
e
t
t
e

2
-
w
a
y
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have separate power specially for the air conditioner. As for the method of wiring, follow the circuit diagram
pasted on the inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the
unit is subjected during the course of transportation. Check them and make sure that they are all tightly fastened. (If they
are loose, it could give rise to burn-out of the wires.)
4) Confirm the specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Do not install the leakage breaker in a place which is wet or moist.
Water or moist may cause short circuit.
9) The following troubles would be caused by voltage drop-down.
Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the normal function of a over-
load protection device.
Proper starting power is not given to the compressor.
CAUTION
HAND OVER
Teach the customer the operation and maintenance procedures, using the operation manual.
(air filter cleaning, temperature control, etc.)
WIRED REMOTE CONTROLLER INSTALLATION
Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place away
from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
Fig.1 Typical locations for remote controller
5feet
(1.5meters)
no
no
no
yes
Remote Controller
TEMP
Remote Controller
TEMP
Remote Controller
TEMP
Indoor unit
Ceiling Cassette 2-way
2-20 2-20
C
a
s
s
e
t
t
e

2
-
w
a
y
11. Accessories
Name
Quantity
Shape
for gas pipe
for liquid pipe
Clamp metal
2 EA
Insulation for
fitting
1 set
Drain hose
1 EA
Clamp
(Tie Wrap)
8 EA
Washer for
hanging bracket
4 EA
Bolt
4 EA
(Other)
Screws for fixing panels are attached to decoration panel.
Standard Accessories
Paper pattern for
installation
Owner's manual
Installation manual
Use only those accessories (Standard or optional) which have designated specifications.
CAUTION
Indoor unit
Ceiling Cassette 4-way
C
a
s
s
e
t
t
e

4
-
w
a
y
1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. Air Velocity and Temperature Distribution
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories
Ceiling Cassette 4-way
Indoor unit
Ceiling Cassette 4-way
3-1 3-1
C
a
s
s
e
t
t
e

4
-
w
a
y
1. List of functions
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Air flow
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Air purifying Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
Installation
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Reliability Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Convenience Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Elevation Grill
Wide wired remote controller
Deluxe wired remote controller
Individual Simple wired remote controller
control Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Special
Zone control
function kit
CTIE
Electro thermostat
4
-
Auto
-
O
4 / 5 / 4
X
O
O
O
X
Option
O
O
X
X
O
O
O
O
O(Heat recovery)
X
O(Heat pump or Cooling only)
O
O
O
O
O
O
O
O
Accessory (TM,TN,TP only)
Accessory
Accessory
Accessory
Accessory
X
Accessory
-
-
-
Function
Category
ARNU05GTR*2, ARNU07GTR*2, ARNU09GTR*2, ARNU12GTR*2
ARNU15GTQ*2, ARNU18GTQ*2, ARNU24GTP*2, ARNU28GTP*2
ARNU36GTN*2, ARNU42GTM*2, ARNU48GTM*2
O : Applied X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.
* Plasma kit and Elevation Grille are not applicable at the same time
Indoor unit
Ceiling Cassette 4-way
3-2 3-2
C
a
s
s
e
t
t
e

4
-
w
a
y
2. Specifications
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
* Model Name
A:Basic, C:Plasma
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Body
mm
Dimensions(WxDxH)
inch
Front Panel
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Fan Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight Body kg(lbs)
Packaged kg(lbs)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Panel Color
Panel Name(Accessory)
4 Way Ceiling Cassette
ARNU05GTR*2 ARNU07GTR*2 ARNU09GTR*2
1.6 2.2 2.8
1,400 1,900 2,400
5,500 7,500 9,600
1.8 2.5 3.2
1,500 2,200 2,800
6,100 8,500 10,900
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
570 x 570 x 214 570 x 570 x 214 570 x 570 x 214
22.4 x 22.4 x 8.4 22.4 x 22.4 x 8.4 22.4 x 22.4 x 8.4
700 x 700 x 30 700 x 700 x 30 700 x 700 x 30
27.5 x 27.5 x 1.2 27.5 x 27.5 x 1.2 27.5 x 27.5 x 1.2
1 x 8 x 18 1 x 8 x 18 2 x 8 x 18
0.21 0.21 0.21
Turbo Fan Turbo Fan Turbo Fan
43 x 1 43 x 1 43 x 1
0.2 0.2 0.2
7.5 / 7.0 / 6.6 7.5 / 7.0 / 6.6 8.0 / 7.5 / 7.1
265 / 247 / 212 265 / 247 / 212 283 / 265 / 251
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Microprocessor, Microprocessor,
Thermostat for cooling Thermostat for cooling Thermostat for cooling
and heating and heating and heating
Foamed polystrene Foamed polystrene Foamed polystrene
Fuse Fuse Fuse
6.35(1/4) 6.35(1/4) 6.35(1/4)
12.7(1/2) 12.7(1/2) 12.7(1/2)
25(1) 25(1) 25(1)
13.1(28.9) 13.1(28.9) 14.2(31.3)
15.4(33.9) 15.4(33.9) 16.5(36.3)
36 / 35 / 33 36 / 35 / 33 36 / 35 / 34
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Morning fog Morning fog Morning fog
PT-UQC
Indoor unit
Ceiling Cassette 4-way
3-3 3-3
C
a
s
s
e
t
t
e

4
-
w
a
y
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
* Model Name
A:Basic, C:Plasma
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Body
mm
Dimensions(WxDxH)
inch
Front Panel
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Fan Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight Body kg(lbs)
Packaged kg(lbs)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Panel Color
Panel Name(Accessory)
4 Way Ceiling Cassette
ARNU12GTR*2 ARNU15GTQ*2 ARNU18GTQ*2
3.6 4.5 5.6
3,100 3,900 4,800
12,300 15,400 19,100
4.0 5.0 6.3
3,400 4,300 5,400
13,600 17,100 21,500
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
570 x 570 x 214 570 x 570 x 256 570 x 570 x 256
22.4 x 22.4 x 8.4 22.4 x 22.4 x 10.1 22.4 x 22.4 x 10.1
700 x 700 x 30 700 x 700 x 30 700 x 700 x 30
27.5 x 27.5 x 1.2 27.5 x 27.5 x 1.2 27.5 x 27.5 x 1.2
2 x 8 x 18 2 x 10 x 18 2 x 10 x 18
0.21 0.27 0.27
Turbo Fan Turbo Fan Turbo Fan
43 x 1 43 x 1 43 x 1
0.2 0.2 0.2
8.7 / 8.0 / 7.0 11.0 / 10.0 / 9.3 11.2 / 11.0 / 10.0
307 / 283 / 247 388 / 353 / 328 396 / 388 / 353
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Microprocessor, Microprocessor,
Thermostat for cooling Thermostat for cooling Thermostat for cooling
and heating and heating and heating
Foamed polystrene Foamed polystrene Foamed polystrene
Fuse Fuse Fuse
6.35(1/4) 6.35(1/4) 6.35(1/4)
12.7(1/2) 12.7(1/2) 12.7(1/2)
25(1) 25(1) 25(1)
14.2(31.3) 15.5(34.2) 15.5(34.2)
16.5(36.3) 18.0(39.7) 18.0(39.7)
36 / 35 / 34 37 / 36 / 35 38 / 37 / 36
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Morning fog Morning fog Morning fog
PT-UQC
Indoor unit
Ceiling Cassette 4-way
3-4 3-4
C
a
s
s
e
t
t
e

4
-
w
a
y
* Model Name
A:Basic, C:Plasma
Type
Model Unit
Cooling Capacity kW
kcal/h
Btu/h
Heating Capacity kW
kcal/h
Btu/h
Casing
Dimensions Body mm
(WxDxH) inch
Front Panel mm
inch
Coil Rows x Columns x FPI
Face Area m
2
Fan Type
Motor Outputx Number W
Running Current A
Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Pipe Liquid Side mm(inch)
Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight Body kg(lbs)
Noise Level (Sound Press, 1.5m, H / M / L) dB(A)
Power Supply
, V, Hz
Refrigerant Control
Power cord
Transmission cable
Panel Color
Panel Name(Accessory)
Elevation Grill(Accessory)
4 Way Ceiling Cassette
ARNU24GTP*2 ARNU28GTP*2 ARNU36GTN*2
7.1 8.2 10.6
6,100 7,100 9,100
24,200 28,000 36,200
8.0 9.2 11.9
6,900 8,000 10,200
27,300 31,500 40,600
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
840 x 840 x 204 840 x 840 x 204 840 x 840 x 246
33.0 x 33.0 x 8.0 33.0 x 33.0 x 8.0 33.0 x 33.0 x 9.7
950 x 950 x 25 950 x 950 x 25 950 x 950 x 25
37.4 x 37.4 x 1 37.4 x 37.4 x 1 37.4 x 37.4 x 1
2 x 8 x 19 2 x 8 x 19 2x10x19
0.40 0.40 0.57
Turbo Fan Turbo Fan Turbo Fan
30 30 135
0.15 0.15 0.56
17 / 15 / 13 19 / 16 / 14 25 / 21 / 19
600 / 529 / 459 671 / 565 / 494 883 / 742 / 671
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene
Fuse Fuse Fuse
9.52(3/8) 9.52(3/8) 9.52(3/8)
15.88(5/8) 15.88(5/8) 15.88(5/8)
25(1) 25(1) 25(1)
20.8(45.8) 20.8(45.8) 23.5(51.8)
36 / 34 / 31 39 / 35 / 33 43 / 40 / 37
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV2.0 X 3C CV2.0 X 3C CV2.0 X 3C
CVV-SB 1.25 X 2C CVV-SB 1.25 X 2C CVV-SB 1.25 X 2C
Morning fog Morning fog Morning fog
PT-UMC
PTEGM0
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Indoor unit
Ceiling Cassette 4-way
3-5 3-5
C
a
s
s
e
t
t
e

4
-
w
a
y
* Model Name
A:Basic, C:Plasma
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Type
Model Unit
Cooling Capacity kW
kcal/h
Btu/h
Heating Capacity kW
kcal/h
Btu/h
Casing
Dimensions Body mm
(WxDxH) inch
Front Panel mm
inch
Coil Rows x Columns x FPI
Face Area m
2
Fan Type
Motor Outputx Number W
Running Current A
Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Pipe Liquid Side mm(inch)
Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight Body kg(lbs)
Noise Level (Sound Press, 1.5m, H / M / L) dB(A)
Power Supply
, V, Hz
Refrigerant Control
Power cord
Transmission cable
Panel Color
Panel Name(Accessory)
Elevation Grill(Accessory)
4 Way Ceiling Cassette
ARNU42GTM*2 ARNU48GTM*2
12.3 14.1
10,600 12,100
42,000 48,100
13.8 15.9
11,000 13,200
43,800 51,200
Galvanized Steel Plate Galvanized Steel Plate
840 x 840 x 288 840 x 840 x 288
33.0 x 33.0 x 11.3 33.0 x 33.0 x 11.3
950 x 950 x 25 950 x 950 x 25
37.4 x 37.4 x 1 37.4 x 37.4 x 1
2 x 12 x 19 2 x 12 x 19
0.57 0.57
Turbo Fan Turbo Fan
135 135
0.56 0.56
30 / 27 / 24 31 / 29 / 27
1,059 / 954 / 848 1,059 / 1,024 / 954
Direct Direct
BLDC BLDC
Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene
Fuse Fuse
9.52(3/8) 9.52(3/8)
15.88(5/8) 15.88(5/8)
25(1) 25(1)
25.6(56.4) 25.6(56.4)
44 / 41 / 38 46 / 43 / 41
1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60
EEV EEV
CV2.0 X 3C CV2.0 X 3C
CVV-SB 1.25 X 2C CVV-SB 1.25 X 2C
Morning fog Morning fog
PT-UMC
PTEGM0
Indoor unit
Ceiling Cassette 4-way
3-6 3-6
C
a
s
s
e
t
t
e

4
-
w
a
y
3. Dimensions
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

T
R
C
e
i
l
i
n
g

C
a
s
s
e
t
t
e

4
-
w
a
y
A
R
N
U
0
5
G
T
R
*
2
A
R
N
U
0
7
G
T
R
*
2
A
R
N
U
0
9
G
T
R
*
2
A
R
N
U
1
2
G
T
R
*
2
N
a
m
e
1
L
i
q
u
i
d

p
i
p
e

c
o
n
n
e
c
t
i
o
n
U
n
i
t

s
i
z
e
(
5
k
,

7
k
,

9
k
,

1
2
k
)
:

6
.
3
5
2
G
a
s

p
i
p
e

c
o
n
n
e
c
t
i
o
n
U
n
i
t

s
i
z
e
(
5
k
,

7
k
,

9
k
,

1
2
k
)
:

1
2
.
7
3
D
r
a
i
n

p
i
p
e

c
o
n
n
e
c
t
i
o
n

4
P
o
w
e
r

s
u
p
p
l
y

c
o
n
n
e
c
t
i
o
n

5
A
i
r

d
i
s
c
h
a
r
g
e

g
r
i
l
l

6
A
i
r

s
u
c
t
i
o
n

g
r
i
l
l

N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
(
u
n
i
t

:

m
m
)
7
0
0
4
7
3
5
5
3
8
0
(
A
i
r

o
u
t
l
e
t

h
o
l
e
)
7 0 0
3 7 8 . 6
3 8 0 ( A i r o u t l e t h o l e )
1
7
2
3
7
8
.
6
4
-
R
2
0
2 2 . 5
5
7
0
5 7 0
5
1
7
6
9
1 2 8
5 1 7
4
6
1
5 2 3
2 1 4
5 3
8 4 . 5 5 9 . 5
7 94 8
1
4
2
.
5
3
0
1
9
5
7
0 1
6
5
6
3
3 4 . 5
2
56
3
1
4
B
r
a
n
c
h

D
u
c
t

C
o
n
n
e
c
t
i
o
n
R
3
5
Indoor unit
Ceiling Cassette 4-way
3-7 3-7
C
a
s
s
e
t
t
e

4
-
w
a
y
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

T
Q
C
e
i
l
i
n
g

C
a
s
s
e
t
t
e

4
-
w
a
y
A
R
N
U
1
5
G
T
Q
*
2
A
R
N
U
1
8
G
T
Q
*
2
N
a
m
e
1
L
i
q
u
i
d

p
i
p
e

c
o
n
n
e
c
t
i
o
n
U
n
i
t

s
i
z
e
(
1
5
k
,

1
8
k
)
:

6
.
3
5
2
G
a
s

p
i
p
e

c
o
n
n
e
c
t
i
o
n
U
n
i
t

s
i
z
e
(
1
5
k
,

1
8
k
)
:

1
2
.
7
3
D
r
a
i
n

p
i
p
e

c
o
n
n
e
c
t
i
o
n

4
P
o
w
e
r

s
u
p
p
l
y

c
o
n
n
e
c
t
i
o
n

5
A
i
r

d
i
s
c
h
a
r
g
e

g
r
i
l
l

6
A
i
r

s
u
c
t
i
o
n

g
r
i
l
l

N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
(
u
n
i
t

:

m
m
)
7
0
0
4
7
3
5
5
3
8
0
(
A
i
r

o
u
t
l
e
t

h
o
l
e
)
7 0 0
3 7 8 . 6
3 8 0 ( A i r o u t l e t h o l e )
1
7
2
3
7
8
.
6
4
-
R
2
0
2 2 . 5
5
7
0
5 7 0
5
1
7
6
8
1 7 4
5 1 7
4
6
1
5 2 3
3
0
1
9
1
4
2
.
5
1
6
5
6
3
9 5 . 5
7 94 8
1 2 5 5 9 . 5
5
7
0
7 6
9 4
2 5 6
2
56
4
3
1
B
r
a
n
c
h

D
u
c
t

C
o
n
n
e
c
t
i
o
n
R
3
5
Indoor unit
Ceiling Cassette 4-way
3-8 3-8
C
a
s
s
e
t
t
e

4
-
w
a
y
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

T
P
C
e
i
l
i
n
g

C
a
s
s
e
t
t
e

4
-
w
a
y
A
R
N
U
2
4
G
T
P
*
2
A
R
N
U
2
8
G
T
P
*
2
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
6
1
8
9 5 0
6 1 8
6 8 4
8 4 0
6 7 1
7
8
7
5 0 0 ( A i r o u t l e t h o l e )
9 9
8 2
6 0
5
0
0
(
A
i
r

o
u
t
l
e
t

h
o
l
e
)
4
-
R
2
0
2
9
2
7
3
4
7
8
7
8
4
0
8
4
0
6
0
3
5
0
1
6
5
8
0
5
3
.
5
1
0
8
5
4
9
5
0
2 5
2 0 4
4 06 5

N
a
m
e
1
L
i
q
u
i
d

p
i
p
e

c
o
n
n
e
c
t
i
o
n
U
n
i
t

s
i
z
e
(
2
4
k
,

2
8
k
)
:

9
.
5
2
2
G
a
s

p
i
p
e

c
o
n
n
e
c
t
i
o
n
U
n
i
t

s
i
z
e
(
2
4
k
,

2
8
k
)
:

1
5
.
8
8

3
D
r
a
i
n

p
i
p
e

c
o
n
n
e
c
t
i
o
n

4
P
o
w
e
r

s
u
p
p
l
y

c
o
n
n
e
c
t
i
o
n

5
A
i
r

d
i
s
c
h
a
r
g
e

g
r
i
l
l


6
A
i
r

s
u
c
t
i
o
n

g
r
i
l
l

N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
(
u
n
i
t

:

m
m
)
43
1
5
6
2
2 0 4
8
0
4
1 5 4
A direction View
126
R35
6
2
A
B
r
a
n
c
h

D
u
c
t

C
o
n
n
e
c
t
i
o
n
7 94 1 . 5
Indoor unit
Ceiling Cassette 4-way
3-9 3-9
C
a
s
s
e
t
t
e

4
-
w
a
y
8
4
0
126
6
2
R35
2 4 6
1 9 5
A direction View
2 5
3
5
0
1 0 05 2
1
6
5
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

T
N
C
e
i
l
i
n
g

C
a
s
s
e
t
t
e

4
-
w
a
y
A
R
N
U
3
6
G
T
N
*
2
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
N
a
m
e
1
L
i
q
u
i
d

p
i
p
e

c
o
n
n
e
c
t
i
o
n
U
n
i
t

s
i
z
e
(
3
6
k
)
:

9
.
5
2
2
G
a
s

p
i
p
e

c
o
n
n
e
c
t
i
o
n
U
n
i
t

s
i
z
e
(
3
6
k
)
:

1
5
.
8
8

3
D
r
a
i
n

p
i
p
e

c
o
n
n
e
c
t
i
o
n

4
P
o
w
e
r

s
u
p
p
l
y

c
o
n
n
e
c
t
i
o
n

5
A
i
r

d
i
s
c
h
a
r
g
e

g
r
i
l
l


6
A
i
r

s
u
c
t
i
o
n

g
r
i
l
l

N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
(
u
n
i
t

:

m
m
)
43
1
5
6
2
A
B
r
a
n
c
h

D
u
c
t

C
o
n
n
e
c
t
i
o
n
1 0 7
7 8
1 0 3
1 4 1
2 4 6
4 0
1
1
0
6
0
8
4
0
8
0
5
3
.
5
Indoor unit
Ceiling Cassette 4-way
3-10 3-10
C
a
s
s
e
t
t
e

4
-
w
a
y
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

T
M
C
e
i
l
i
n
g

C
a
s
s
e
t
t
e

4
-
w
a
y
A
R
N
U
4
2
G
T
M
*
2
A
R
N
U
4
8
G
T
M
*
2
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
N
a
m
e

1

L
i
q
u
i
d

p
i
p
e

c
o
n
n
e
c
t
i
o
n

U
n
i
t

s
i
z
e
(
4
2
k
,

4
8
k
)
:

9
.
5
2

2

G
a
s

p
i
p
e

c
o
n
n
e
c
t
i
o
n

U
n
i
t

s
i
z
e
(
4
2
k
,

4
8
k
)
:

1
5
.
8
8


3

D
r
a
i
n

p
i
p
e

c
o
n
n
e
c
t
i
o
n


4

P
o
w
e
r

s
u
p
p
l
y

c
o
n
n
e
c
t
i
o
n


5

A
i
r

d
i
s
c
h
a
r
g
e

g
r
i
l
l



6

A
i
r

s
u
c
t
i
o
n

g
r
i
l
l

N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
(
u
n
i
t

:

m
m
)
43
1
2
5
6
8
4
0
1
0
9
R35
126
2 8 8
2 3 7
A direction View
A
2 5
B
r
a
n
c
h

D
u
c
t

C
o
n
n
e
c
t
i
o
n
3
5
0
5
3
.
5
1 0 08 4
1
6
5
Indoor unit
Ceiling Cassette 4-way
3-11 3-11
C
a
s
s
e
t
t
e

4
-
w
a
y
4. Piping Diagrams
Heat Exchanger
Turbo Fan
Th3
Th1
Th2
lndoor unit
EEV
:Heating
:Cooling
Filter
Filter
Refrigerant pipe connection port diameter
[Unit: mm(inch)]
Model
ARNU05GTR*2
ARNU07GTR*2
ARNU09GTR*2
ARNU12GTR*2
ARNU15GTQ*2
ARNU18GTQ*2
ARNU24GTP*2
ARNU28GTP*2
ARNU36GTN*2
ARNU42GTM*2
ARNU48GTM*2
Gas
12.7(1/2)
12.7(1/2)
12.7(1/2)
12.7(1/2)
12.7(1/2)
12.7(1/2)
15.88(5/8)
15.88(5/8)
15.88(5/8)
15.88(5/8)
15.88(5/8)
Liquid
6.35(1/4)
6.35(1/4)
6.35(1/4)
6.35(1/4)
6.35(1/4)
6.35(1/4)
9.52(3/8)
9.52(3/8)
9.52(3/8)
9.52(3/8)
9.52(3/8)
LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor
Indoor unit
Ceiling Cassette 4-way
3-12 3-12
C
a
s
s
e
t
t
e

4
-
w
a
y
5. Wiring Diagrams
CONNECTOR NUMBER LOCATION POINT FUNCTION
CN-POWER AC Power supply AC Power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC output for drain pump
CN-485 Communication Connection between indoor and outdoor
CN-DISP Display Display of indoor status
CN-EEV EEV Output EEV Control output
CN-VANE2 Step motor Step motor output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room air thermistor
CN-REMO Remote controller Remote control line
CN-CC Dry contact Dry contact line
CN-AIRC Air clean Air cleaner control
TR/TQ Chassis
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor
CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.
Indoor unit
Ceiling Cassette 4-way
3-13 3-13
C
a
s
s
e
t
t
e

4
-
w
a
y
CONNECTOR NUMBER LOCATION POINT FUNCTION
CN-POWER AC Power supply AC Power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC output for drain pump
CN-485 Communication Connection between indoor and outdoor
CN-DISP Display Display of indoor status
CN-EEV EEV Output EEV Control output
CN-VANE1 / VANE2 Step motor Step motor output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room air thermistor
CN-REMO Remote controller Remote control line
CN-CC Dry contact Dry contact line
CN-AIRC Air clean Air cleaner control
TM/TN/TP Chassis
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor
CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.
Indoor unit
Ceiling Cassette 4-way
3-14 3-14
C
a
s
s
e
t
t
e

4
-
w
a
y
6. Capacity Tables
6.1 Cooling Capacity
Notes:
TC: Total Capacity(kW)
SHC: Sensible Heat Capacity(kW)
Cooling capacity
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.3 1.9 1.3 2.1 1.3
12 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.3 1.9 1.3 2.1 1.3
14 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.3 1.9 1.3 2.1 1.3
16 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.3 1.9 1.3 2.0 1.2
18 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.3 1.9 1.3 2.0 1.2
20 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.3 1.9 1.3 2.0 1.2
21 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.3 1.9 1.3 2.0 1.2
23 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.3 1.9 1.3 1.9 1.2
25 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.3 1.9 1.3 1.9 1.2
27 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.3 1.9 1.3 1.9 1.2
29 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.3 1.9 1.3 1.8 1.1
31 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.3 1.9 1.3 1.8 1.1
33 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.3 1.9 1.3 1.8 1.1
35 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.3 1.9 1.3 1.8 1.1
37 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.3 1.9 1.3 1.7 1.1
39 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.3 1.9 1.3 1.7 1.1
10 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.7 2.3 1.7 2.6 1.8 2.9 1.8
12 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.7 2.3 1.7 2.6 1.8 2.9 1.7
14 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.7 2.3 1.7 2.6 1.8 2.8 1.7
16 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.7 2.3 1.7 2.6 1.8 2.8 1.7
18 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.7 2.3 1.7 2.6 1.8 2.7 1.7
20 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.7 2.3 1.7 2.6 1.8 2.7 1.6
21 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.7 2.3 1.7 2.6 1.8 2.7 1.6
23 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.7 2.3 1.7 2.6 1.8 2.6 1.6
25 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.7 2.3 1.7 2.6 1.8 2.6 1.6
27 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.7 2.3 1.7 2.6 1.8 2.6 1.6
29 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.7 2.3 1.7 2.6 1.8 2.5 1.5
31 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.7 2.3 1.7 2.6 1.8 2.5 1.5
33 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.7 2.3 1.7 2.6 1.8 2.5 1.5
35 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.7 2.3 1.7 2.6 1.8 2.4 1.5
37 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.7 2.3 1.7 2.6 1.8 2.4 1.5
39 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.7 2.3 1.7 2.6 1.8 2.3 1.4
10 1.9 1.7 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.7 2.1
12 1.9 1.7 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.6 2.1
14 1.9 1.7 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.6 2.1
16 1.9 1.7 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.5 2.1
18 1.9 1.7 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.5 2.0
20 1.9 1.7 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
21 1.9 1.7 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
23 1.9 1.7 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
25 1.9 1.7 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.3 1.9
27 1.9 1.7 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.3 1.9
29 1.9 1.7 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.2 1.9
31 1.9 1.7 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.2 1.9
33 1.9 1.7 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.1 1.8
35 1.9 1.7 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.1 1.8
37 1.9 1.7 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.0 1.8
39 1.9 1.7 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.0 1.7
2.2
2.8
1.6
Indoor unit
Ceiling Cassette 4-way
3-15 3-15
C
a
s
s
e
t
t
e

4
-
w
a
y
Notes:
TC: Total Capacity(kW)
SHC: Sensible Heat Capacity(kW)
Cooling capacity
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
4.5
5.6
3.6
10 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.5 3.8 2.6 4.3 2.7 4.7 2.7
12 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.5 3.8 2.6 4.3 2.7 4.7 2.6
14 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.5 3.8 2.6 4.3 2.7 4.6 2.6
16 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.5 3.8 2.6 4.3 2.7 4.6 2.6
18 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.5 3.8 2.6 4.3 2.7 4.5 2.5
20 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.5 3.8 2.6 4.3 2.7 4.4 2.5
21 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.5 3.8 2.6 4.3 2.7 4.4 2.5
23 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.5 3.8 2.6 4.3 2.7 4.3 2.5
25 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.5 3.8 2.6 4.3 2.7 4.3 2.4
27 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.5 3.8 2.6 4.3 2.7 4.2 2.4
29 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.5 3.8 2.6 4.3 2.7 4.2 2.4
31 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.5 3.8 2.6 4.3 2.7 4.1 2.3
33 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.5 3.8 2.6 4.3 2.7 4.0 2.3
35 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.5 3.8 2.6 4.3 2.7 4.0 2.2
37 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.5 3.8 2.6 4.3 2.7 3.9 2.2
39 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.5 3.8 2.6 4.3 2.7 3.8 2.2
10 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.9 3.5
12 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.8 3.5
14 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.8 3.4
16 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.7 3.4
18 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.6 3.3
20 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.5 3.3
21 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.5 3.3
23 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.4 3.2
25 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.3 3.2
27 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.3 3.1
29 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.2 3.1
31 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.1 3.0
33 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.0 3.0
35 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.0 2.9
37 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 4.9 2.9
39 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 4.8 2.8
10 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.4 4.2
12 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.3 4.1
14 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.2 4.1
16 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.1 4.0
18 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.0 4.0
20 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.9 3.9
21 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.8 3.9
23 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.7 3.8
25 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.6 3.8
27 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.6 3.7
29 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.5 3.7
31 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.4 3.6
33 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.3 3.6
35 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.2 3.5
37 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.1 3.5
39 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.0 3.4
Indoor unit
Ceiling Cassette 4-way
3-16 3-16
C
a
s
s
e
t
t
e

4
-
w
a
y
Notes:
TC: Total Capacity(kW)
SHC: Sensible Heat Capacity(kW)
Cooling capacity
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.7 8.2 13.9 8.1
12 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.7 8.2 13.7 8.0
14 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.7 8.2 13.6 7.9
16 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.7 8.2 13.4 7.8
18 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.7 8.2 13.2 7.7
20 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.7 8.2 13.0 7.6
21 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.7 8.2 12.9 7.6
23 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.7 8.2 12.8 7.5
25 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.5 8.1 12.6 7.3
27 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.2 7.9 12.4 7.3
29 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.1 7.8 12.2 7.1
31 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 11.9 7.7 12.0 7.0
33 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 11.7 7.6 11.8 6.9
35 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 11.4 7.4 11.7 6.8
37 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.0 7.7 11.2 7.3 11.5 6.7
39 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 10.8 7.5 11.0 7.1 11.3 6.6
8.2
10.6
10 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.3 5.4
12 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.2 5.4
14 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.1 5.3
16 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.0 5.2
18 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.8 5.2
20 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.7 5.1
21 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.7 5.1
23 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.5 5.0
25 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.4 5.4 8.4 4.9
27 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.2 5.3 8.3 4.9
29 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.1 5.2 8.2 4.8
31 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.0 5.1 8.1 4.7
33 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 7.8 5.1 7.9 4.6
35 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 7.7 5.0 7.8 4.6
37 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.4 5.1 7.5 4.9 7.7 4.5
39 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.2 5.0 7.4 4.8 7.6 4.4
10 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.8 6.4 10.8 6.3
12 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.8 6.4 10.6 6.2
14 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.8 6.4 10.5 6.1
16 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.8 6.4 10.4 6.1
18 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.8 6.4 10.2 6.0
20 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.8 6.4 10.1 5.9
21 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.8 6.4 10.0 5.8
23 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.8 6.4 9.9 5.8
25 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.7 6.3 9.7 5.7
27 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.4 6.1 9.6 5.6
29 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.3 6.1 9.5 5.5
31 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.2 5.9 9.3 5.4
33 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.0 5.8 9.2 5.4
35 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 8.9 5.7 9.0 5.3
37 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.5 5.9 8.7 5.6 8.9 5.2
39 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.4 5.8 8.5 5.5 8.8 5.1
7.1
Indoor unit
Ceiling Cassette 4-way
3-17 3-17
C
a
s
s
e
t
t
e

4
-
w
a
y
Notes:
TC: Total Capacity(kW)
SHC: Sensible Heat Capacity(kW)
Cooling capacity
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.9 10.9 18.5 10.8
12 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.9 10.9 18.3 10.7
14 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.9 10.9 18.1 10.6
16 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.9 10.9 17.8 10.4
18 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.9 10.9 17.6 10.3
20 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.9 10.9 17.3 10.1
21 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.9 10.9 17.2 10.1
23 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.9 10.9 17.0 9.9
25 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.6 10.8 16.7 9.8
27 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.2 10.5 16.5 9.6
29 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.1 10.4 16.3 9.5
31 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 15.8 10.2 16.0 9.4
33 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 15.5 10.0 15.8 9.2
35 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 15.2 9.9 15.5 9.1
37 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 14.7 10.2 14.9 9.7 15.3 8.9
39 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 14.4 10.0 14.7 9.5 15.1 8.8
10 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.7 9.5 16.2 9.4
12 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.7 9.5 15.9 9.3
14 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.7 9.5 15.8 9.2
16 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.7 9.5 15.6 9.1
18 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.7 9.5 15.3 9.0
20 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.7 9.5 15.1 8.8
21 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.7 9.5 15.0 8.8
23 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.7 9.5 14.8 8.6
25 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.5 9.4 14.6 8.5
27 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.1 9.2 14.4 8.4
29 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.0 9.1 14.2 8.3
31 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 13.8 8.9 14.0 8.2
33 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 13.5 8.8 13.7 8.0
35 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 13.3 8.6 13.5 7.9
37 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 12.8 8.9 13.0 8.4 13.4 7.8
39 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 12.5 8.7 12.8 8.3 13.1 7.7
14.1 14.1
12.3
Indoor unit
Ceiling Cassette 4-way
3-18 3-18
C
a
s
s
e
t
t
e

4
-
w
a
y
6.2 Heating Capacity
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 1.2 1.2 1.2 1.2 1.2 1.2
-18.8 -19.0 1.2 1.2 1.2 1.2 1.2 1.2
-16.7 -17.0 1.3 1.3 1.3 1.3 1.3 1.3
-14.7 -15.0 1.4 1.4 1.2 1.4 1.4 1.4
-12.6 -13.0 1.5 1.5 1.3 1.4 1.4 1.4
-10.5 -11.0 1.5 1.5 1.4 1.5 1.5 1.5
-9.5 -10.0 1.5 1.5 1.4 1.5 1.5 1.5
-8.5 -9.1 1.6 1.6 1.4 1.6 1.6 1.5
-7.0 -7.6 1.6 1.6 1.5 1.6 1.6 1.6
-5.0 -5.6 1.7 1.7 1.5 1.7 1.7 1.6
-3.0 -3.7 1.8 1.8 1.6 1.7 1.7 1.6
0.0 -0.7 1.9 1.9 1.7 1.7 1.7 1.6
3.0 2.2 2.0 1.9 1.8 1.7 1.7 1.6
5.0 4.1 2.0 1.9 1.8 1.7 1.7 1.6
7.0 6.0 2.1 1.9 1.8 1.7 1.7 1.6
9.0 7.9 2.1 1.9 1.8 1.7 1.7 1.6
11.0 9.8 2.1 1.9 1.8 1.7 1.7 1.6
13.0 11.8 2.1 1.9 1.8 1.7 1.7 1.6
15.0 13.7 2.1 1.9 1.8 1.7 1.7 1.6
-19.8 -20.0 1.7 1.7 1.7 1.7 1.7 1.7
-18.8 -19.0 1.7 1.7 1.7 1.7 1.7 1.7
-16.7 -17.0 1.8 1.8 1.8 1.8 1.8 1.8
-14.7 -15.0 1.9 1.9 1.7 1.9 1.9 1.9
-12.6 -13.0 2.0 2.0 1.8 2.0 2.0 2.0
-10.5 -11.0 2.1 2.1 1.9 2.1 2.1 2.1
-9.5 -10.0 2.2 2.2 1.9 2.2 2.2 2.1
-8.5 -9.1 2.2 2.2 2.0 2.2 2.2 2.1
-7.0 -7.6 2.3 2.3 2.0 2.2 2.2 2.2
-5.0 -5.6 2.4 2.4 2.1 2.3 2.3 2.2
-3.0 -3.7 2.5 2.5 2.2 2.4 2.4 2.2
0.0 -0.7 2.6 2.6 2.3 2.4 2.4 2.2
3.0 2.2 2.8 2.7 2.4 2.4 2.4 2.2
5.0 4.1 2.8 2.7 2.5 2.4 2.4 2.2
7.0 6.0 2.9 2.7 2.5 2.4 2.4 2.2
9.0 7.9 2.9 2.7 2.5 2.4 2.4 2.2
11.0 9.8 2.9 2.7 2.5 2.4 2.4 2.2
13.0 11.8 2.9 2.7 2.5 2.4 2.4 2.2
15.0 13.7 2.9 2.7 2.5 2.4 2.4 2.2
-19.8 -20.0 2.1 2.1 2.1 2.1 2.1 2.1
-18.8 -19.0 2.2 2.2 2.2 2.2 2.2 2.2
-16.7 -17.0 2.3 2.3 2.3 2.3 2.3 2.3
-14.7 -15.0 2.5 2.4 2.2 2.4 2.4 2.4
-12.6 -13.0 2.6 2.6 2.3 2.6 2.6 2.6
-10.5 -11.0 2.7 2.7 2.4 2.7 2.7 2.7
-9.5 -10.0 2.8 2.8 2.5 2.8 2.8 2.7
-8.5 -9.1 2.8 2.8 2.5 2.8 2.8 2.7
-7.0 -7.6 2.9 2.9 2.6 2.8 2.8 2.8
-5.0 -5.6 3.0 3.0 2.7 3.0 3.0 2.8
-3.0 -3.7 3.2 3.2 2.8 3.1 3.0 2.8
0.0 -0.7 3.4 3.4 3.0 3.1 3.0 2.8
3.0 2.2 3.6 3.4 3.1 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.7 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.7 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.7 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.7 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.7 3.4 3.2 3.1 3.0 2.8
1.6
2.2
2.8
Notes:
TC: Total Capacity(kW)
Heating capacity
Indoor unit
Ceiling Cassette 4-way
3-19 3-19
C
a
s
s
e
t
t
e

4
-
w
a
y
Notes:
TC: Total Capacity(kW)
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 2.7 2.7 2.7 2.6 2.6 2.6
-18.8 -19.0 2.8 2.8 2.8 2.8 2.7 2.7
-16.7 -17.0 2.9 2.9 2.9 2.9 2.9 2.9
-14.7 -15.0 3.1 3.0 2.7 3.0 3.0 3.0
-12.6 -13.0 3.2 3.2 2.9 3.2 3.2 3.2
-10.5 -11.0 3.4 3.4 3.0 3.4 3.4 3.4
-9.5 -10.0 3.4 3.4 3.1 3.4 3.4 3.4
-8.5 -9.1 3.5 3.5 3.2 3.5 3.5 3.4
-7.0 -7.6 3.6 3.6 3.3 3.6 3.6 3.5
-5.0 -5.6 3.8 3.8 3.4 3.7 3.7 3.5
-3.0 -3.7 4.0 4.0 3.5 3.9 3.8 3.5
0.0 -0.7 4.2 4.2 3.7 3.9 3.8 3.5
3.0 2.2 4.4 4.3 3.9 3.9 3.8 3.5
5.0 4.1 4.5 4.3 4.0 3.9 3.8 3.5
7.0 6.0 4.6 4.3 4.0 3.9 3.8 3.5
9.0 7.9 4.6 4.3 4.0 3.9 3.8 3.5
11.0 9.8 4.6 4.3 4.0 3.9 3.8 3.5
13.0 11.8 4.6 4.3 4.0 3.9 3.8 3.5
15.0 13.7 4.6 4.3 4.0 3.9 3.8 3.5
-19.8 -20.0 3.4 3.4 3.4 3.3 3.3 3.3
-18.8 -19.0 3.5 3.5 3.5 3.5 3.4 3.4
-16.7 -17.0 3.7 3.7 3.7 3.7 3.7 3.6
-14.7 -15.0 3.9 3.8 3.4 3.8 3.8 3.8
-12.6 -13.0 4.1 4.1 3.6 4.0 4.0 4.0
-10.5 -11.0 4.3 4.3 3.8 4.3 4.2 4.2
-9.5 -10.0 4.3 4.3 3.9 4.3 4.3 4.3
-8.5 -9.1 4.4 4.4 4.0 4.4 4.4 4.3
-7.0 -7.6 4.6 4.6 4.1 4.4 4.4 4.4
-5.0 -5.6 4.8 4.8 4.3 4.6 4.6 4.4
-3.0 -3.7 5.0 5.0 4.4 4.8 4.7 4.4
0.0 -0.7 5.3 5.3 4.6 4.8 4.7 4.4
3.0 2.2 5.6 5.4 4.9 4.8 4.7 4.4
5.0 4.1 5.6 5.4 5.0 4.8 4.7 4.4
7.0 6.0 5.8 5.4 5.0 4.8 4.7 4.4
9.0 7.9 5.8 5.4 5.0 4.8 4.7 4.4
11.0 9.8 5.8 5.4 5.0 4.8 4.7 4.4
13.0 11.8 5.8 5.4 5.0 4.8 4.7 4.4
15.0 13.7 5.8 5.4 5.0 4.8 4.7 4.4
-19.8 -20.0 4.2 4.2 4.2 4.2 4.2 4.2
-18.8 -19.0 4.3 4.3 4.3 4.3 4.3 4.3
-16.7 -17.0 4.6 4.6 4.6 4.6 4.6 4.5
-14.7 -15.0 4.9 4.8 4.3 4.8 4.8 4.8
-12.6 -13.0 5.1 5.1 4.5 5.0 5.0 5.0
-10.5 -11.0 5.4 5.4 4.8 5.4 5.3 5.3
-9.5 -10.0 5.4 5.4 4.9 5.4 5.4 5.4
-8.5 -9.1 5.5 5.5 5.0 5.5 5.5 5.4
-7.0 -7.6 5.7 5.7 5.1 5.6 5.6 5.5
-5.0 -5.6 6.0 6.0 5.4 5.8 5.8 5.5
-3.0 -3.7 6.2 6.2 5.5 6.1 5.9 5.5
0.0 -0.7 6.6 6.6 5.8 6.1 5.9 5.5
3.0 2.2 7.0 6.7 6.2 6.1 5.9 5.5
5.0 4.1 7.1 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.2 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.2 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.2 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.2 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.2 6.7 6.3 6.1 5.9 5.5
3.6
4.5
5.6
Heating capacity
Indoor unit
Ceiling Cassette 4-way
3-20 3-20
C
a
s
s
e
t
t
e

4
-
w
a
y
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 5.4 5.4 5.4 5.3 5.3 5.3
-18.8 -19.0 5.5 5.5 5.5 5.5 5.4 5.4
-16.7 -17.0 5.8 5.8 5.8 5.8 5.8 5.8
-14.7 -15.0 6.2 6.1 5.5 6.1 6.1 6.1
-12.6 -13.0 6.5 6.5 5.8 6.4 6.4 6.4
-10.5 -11.0 6.8 6.8 6.0 6.8 6.7 6.7
-9.5 -10.0 6.9 6.9 6.2 6.9 6.9 6.8
-8.5 -9.1 7.0 7.0 6.3 7.0 7.0 6.8
-7.0 -7.6 7.3 7.3 6.5 7.1 7.1 7.0
-5.0 -5.6 7.6 7.6 6.8 7.4 7.4 7.0
-3.0 -3.7 7.9 7.9 7.0 7.7 7.5 7.0
0.0 -0.7 8.4 8.4 7.4 7.8 7.5 7.0
3.0 2.2 8.9 8.6 7.8 7.8 7.5 7.0
5.0 4.1 9.0 8.6 8.0 7.8 7.5 7.0
7.0 6.0 9.2 8.6 8.0 7.8 7.5 7.0
9.0 7.9 9.2 8.6 8.0 7.8 7.5 7.0
11.0 9.8 9.2 8.6 8.0 7.8 7.5 7.0
13.0 11.8 9.2 8.6 8.0 7.8 7.5 7.0
15.0 13.7 9.2 8.6 8.0 7.8 7.5 7.0
-19.8 -20.0 6.2 6.2 6.2 6.1 6.1 6.1
-18.8 -19.0 6.3 6.3 6.3 6.3 6.3 6.3
-16.7 -17.0 6.7 6.7 6.7 6.7 6.7 6.6
-14.7 -15.0 7.1 7.0 6.3 7.0 7.0 7.0
-12.6 -13.0 7.5 7.5 6.6 7.4 7.4 7.4
-10.5 -11.0 7.8 7.8 7.0 7.8 7.7 7.7
-9.5 -10.0 7.9 7.9 7.1 7.9 7.9 7.8
-8.5 -9.1 8.1 8.1 7.3 8.1 8.1 7.9
-7.0 -7.6 8.4 8.4 7.5 8.2 8.2 8.0
-5.0 -5.6 8.7 8.7 7.8 8.5 8.5 8.0
-3.0 -3.7 9.1 9.1 8.1 8.9 8.6 8.0
0.0 -0.7 9.7 9.7 8.5 8.9 8.6 8.0
3.0 2.2 10.2 9.8 9.0 8.9 8.6 8.0
5.0 4.1 10.4 9.8 9.2 8.9 8.6 8.0
7.0 6.0 10.6 9.8 9.2 8.9 8.6 8.0
9.0 7.9 10.6 9.8 9.2 8.9 8.6 8.0
11.0 9.8 10.6 9.8 9.2 8.9 8.6 8.0
13.0 11.8 10.6 9.8 9.2 8.9 8.6 8.0
15.0 13.7 10.6 9.8 9.2 8.9 8.6 8.0
-19.8 -20.0 8.0 8.0 8.0 7.9 7.9 7.9
-18.8 -19.0 8.2 8.2 8.2 8.2 8.1 8.1
-16.7 -17.0 8.7 8.7 8.7 8.7 8.7 8.6
-14.7 -15.0 9.2 9.0 8.2 9.0 9.0 9.1
-12.6 -13.0 9.6 9.6 8.6 9.5 9.5 9.5
-10.5 -11.0 10.1 10.1 9.0 10.1 10.0 10.0
-9.5 -10.0 10.2 10.2 9.2 10.2 10.2 10.1
-8.5 -9.1 10.5 10.5 9.4 10.5 10.5 10.2
-7.0 -7.6 10.8 10.8 9.7 10.6 10.6 10.4
-5.0 -5.6 11.3 11.3 10.1 11.0 11.0 10.4
-3.0 -3.7 11.8 11.8 10.4 11.5 11.2 10.4
0.0 -0.7 12.5 12.5 11.0 11.5 11.2 10.4
3.0 2.2 13.2 12.7 11.6 11.5 11.2 10.4
5.0 4.1 13.4 12.7 11.9 11.5 11.2 10.4
7.0 6.0 13.7 12.7 11.9 11.5 11.2 10.4
9.0 7.9 13.7 12.7 11.9 11.5 11.2 10.4
11.0 9.8 13.7 12.7 11.9 11.5 11.2 10.4
13.0 11.8 13.7 12.7 11.9 11.5 11.2 10.4
15.0 13.7 13.7 12.7 11.9 11.5 11.2 10.4
7.1
8.2
10.6
Notes:
TC: Total Capacity(kW)
Heating capacity
Indoor unit
Ceiling Cassette 4-way
3-21 3-21
C
a
s
s
e
t
t
e

4
-
w
a
y
Notes:
TC: Total Capacity(kW)
Heating capacity
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 9.2 9.2 9.2 9.1 9.1 9.1
-18.8 -19.0 9.5 9.5 9.5 9.5 9.4 9.4
-16.7 -17.0 10.1 10.1 10.1 10.1 10.1 9.9
-14.7 -15.0 10.6 10.5 9.5 10.5 10.5 10.5
-12.6 -13.0 11.2 11.2 10.0 11.0 11.0 11.0
-10.5 -11.0 11.7 11.7 10.4 11.7 11.6 11.6
-9.5 -10.0 11.9 11.9 10.7 11.9 11.9 11.7
-8.5 -9.1 12.1 12.1 10.9 12.1 12.1 11.8
-7.0 -7.6 12.6 12.6 11.3 12.2 12.2 12.1
-5.0 -5.6 13.1 13.1 11.7 12.8 12.8 12.1
-3.0 -3.7 13.7 13.7 12.1 13.3 13.0 12.1
0.0 -0.7 14.5 14.5 12.8 13.4 13.0 12.1
3.0 2.2 15.3 14.8 13.5 13.4 13.0 12.1
5.0 4.1 15.5 14.8 13.8 13.4 13.0 12.1
7.0 6.0 15.9 14.8 13.8 13.4 13.0 12.1
9.0 7.9 15.9 14.8 13.8 13.4 13.0 12.1
11.0 9.8 15.9 14.8 13.8 13.4 13.0 12.1
13.0 11.8 15.9 14.8 13.8 13.4 13.0 12.1
15.0 13.7 15.9 14.8 13.8 13.4 13.0 12.1
12.3
-19.8 -20.0 10.7 10.7 10.7 10.5 10.5 10.5
-18.8 -19.0 11.0 11.0 11.0 11.0 10.8 10.8
-16.7 -17.0 11.6 11.6 11.6 11.6 11.6 11.4
-14.7 -15.0 12.2 12.1 10.9 12.1 12.1 12.1
-12.6 -13.0 12.9 12.9 11.5 12.7 12.7 12.7
-10.5 -11.0 13.5 13.5 12.0 13.5 13.4 13.4
-9.5 -10.0 13.7 13.7 12.3 13.7 13.7 13.5
-8.5 -9.1 14.0 14.0 12.6 14.0 14.0 13.6
-7.0 -7.6 14.5 14.5 13.0 14.1 14.1 13.9
-5.0 -5.6 15.1 15.1 13.5 14.7 14.7 13.9
-3.0 -3.7 15.7 15.7 13.9 15.3 14.9 13.9
0.0 -0.7 16.7 16.7 14.7 15.4 14.9 13.9
3.0 2.2 17.7 17.0 15.5 15.4 14.9 13.9
5.0 4.1 17.9 17.0 15.9 15.4 14.9 13.9
7.0 6.0 18.3 17.0 15.9 15.4 14.9 13.9
9.0 7.9 18.3 17.0 15.9 15.4 14.9 13.9
11.0 9.8 18.3 17.0 15.9 15.4 14.9 13.9
13.0 11.8 18.3 17.0 15.9 15.4 14.9 13.9
15.0 13.7 18.3 17.0 15.9 15.4 14.9 13.9
14.1
Indoor unit
Ceiling Cassette 4-way
3-22 3-22
C
a
s
s
e
t
t
e

4
-
w
a
y
7. Air Velocity and Temperature Distribution(Reference Data)
ARNU05GTR*2, ARNU07GTR*2, ARNU09GTR*2
Discharge angle: 40
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
1.5m 1.5m 2.5m 2.5m 0m
2.0 2.0
1.5
1.5
1.0
1.0
0.5
0.5
2.7m
2m
1m
0m
1.5m 1.5m 2.5m 2.5m 0m
18
20
22
24
18
20
22
24
Discharge angle: 50
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
1.5m 1.5m 2.5m 2.5m 0m
2.7m
2m
1m
0m
1.5m 1.5m 2.5m 2.5m 0m
33 33
27 27
24
24
21
18
21
18
2.0
1.5
1.0
0.5
2.0
1.5
1.0
0.5
Cooling Heating
ARNU12GTR*2
Discharge angle: 40
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
1.5m 1.5m 2.5m 2.5m 0m
2.0 2.0
1.5 1.5
1.0 1.0
0.5 0.5
2.7m
2m
1m
0m
1.5m 1.5m 2.5m 2.5m 0m
18 18
20 20
22 22
24 24
Discharge angle: 50
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
1.5m 1.5m 2.5m 2.5m 0m
2.0 2.0
1.5 1.5
1.0 1.0
0.5 0.5
2.7m
2m
1m
0m
1.5m 1.5m 2.5m 2.5m 0m
33 33
30 30
27 27
24 24
21 21
Cooling Heating
Indoor unit
Ceiling Cassette 4-way
3-23 3-23
C
a
s
s
e
t
t
e

4
-
w
a
y
ARNU18GTQ*2
Discharge angle: 40
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
4m 3m 3m 4m 2m 2m 1m 1m 0m
2.7m
2m
1m
0m
4m 3m 3m 4m 2m 2m 1m 1m 0m
18 18
20 20
22 22
24 24
2.0 2.0
1.5 1.5
1.0 1.0
0.5 0.5
Discharge angle: 50
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
4m 3m 3m 4m 2m 2m 1m 1m 0m
2.7m
2m
1m
0m
4m 3m 3m 4m 2m 2m 1m 1m 0m
2.0 2.0
1.5 1.5
1.0 1.0
0.5 0.5
33 33
30 30
27 27
24 24
21 21
Cooling Heating
ARNU15GTQ*2
Discharge angle: 40
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
4m 3m 3m 4m 2m 2m 1m 1m 0m
2.7m
2m
1m
0m
4m 3m 3m 4m 2m 2m 1m 1m 0m
2.0
2.0
1.5 1.5
1.0
1.0
0.5 0.5
Discharge angle: 50
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
4m 3m 3m 4m 2m 2m 1m 1m 0m
2.7m
2m
1m
0m
4m 3m 3m 4m 2m 2m 1m 1m 0m
33 33
27 27
24
24
21 21
24
2.0
2.0
1.5
1.5
1.0 1.0
0.5
0.5
18
18
20
22
22
20
24
Cooling Heating
Indoor unit
Ceiling Cassette 4-way
3-24 3-24
C
a
s
s
e
t
t
e

4
-
w
a
y
ARNU28GTP*2
Discharge angle: 40
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
4m 3m 3m 4m 2m 2m 1m 1m 0m
2.7m
2m
1m
0m
4m 3m 3m 4m 2m 2m 1m 1m 0m
2.5 2.5
2.0
2.0
1.5 1.5
1.0 1.0
Discharge angle: 50
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
4m 3m 3m 4m 2m 2m 1m 1m 0m
2.7m
2m
1m
0m
4m 3m 3m 4m 2m 2m 1m 1m 0m
30 30
27 27
24
24
21 21
3.0
2.0 2.0
1.5 1.5
1.0 1.0
0.5 0.5
18 18
22
22
23 23
3.0
33 33
Cooling Heating
ARNU24GTP*2
Discharge angle: 40
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
4m 3m 3m 4m 2m 2m 1m 1m 0m
2.7m
2m
1m
0m
4m 3m 3m 4m 2m 2m 1m 1m 0m
2.0
2.0
1.5 1.5
1.0 1.0
Discharge angle: 50
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
4m 3m 3m 4m 2m 2m 1m 1m 0m
2.7m
2m
1m
0m
4m 3m 3m 4m 2m 2m 1m 1m 0m
33 33
30 30
27 27
24
24
22
22
24 24
2.0 2.0
1.0 1.0
0.5 0.5
20
18 18
20
22 22
23 23
Cooling Heating
Indoor unit
Ceiling Cassette 4-way
3-25 3-25
C
a
s
s
e
t
t
e

4
-
w
a
y
ARNU36GTN*2
Discharge angle: 40
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
2.7m
2m
1m
2.0
2.5 2.5
3.0 3.0
2.0
1.5 1.5
1.0 1.0
Discharge angle: 50
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
2.7m
2m
1m
30 30
27 27
24
24
22
22
23 23
18
20 20
22
22
0m
4m 5m 3m 5m 2m 1m 1m 0m 3m 2m 4m
0m
4m 5m 3m 5m 2m 1m 1m 0m 3m 2m 4m
0m
4m 5m 3m 5m 2m 1m 1m 0m 3m 2m 4m
0m
4m 5m 3m 5m 2m 1m 1m 0m 3m 2m 4m
3.5
3.0 3.0
3.5
2.5
2.5
2.0
2.0
1.0 1.0
18 33 33
Cooling Heating
ARNU42GTM*2
Discharge angle: 40
Air velocity [m/s]
Temperature [C]
4.0
4.0
3.0 3.0
2.0 2.0
1.0
1.0
Discharge angle: 50
Air velocity [m/s]
Temperature [C]
3.2m
0m
4m 5m 3m 5m 2m 1m 1m 0m
2m
1m
3m 2m 4m
3.2m
0m
4m 5m 3m 5m 2m 1m 1m 0m
2m
1m
3m 2m 4m
3.2m
0m
4m 5m 3m 5m 2m 1m 1m 0m
2m
1m
3m 2m 4m
3.2m
0m
4m 5m 3m 5m 2m 1m 1m 0m
2m
1m
3m 2m 4m
24
33 33
24
27 27
30 30
22 22
4.0 4.0
3.0 3.0
2.0 2.0
1.0 1.0
18 18
20
20
22 22
24 24
Cooling Heating
Indoor unit
Ceiling Cassette 4-way
3-26 3-26
C
a
s
s
e
t
t
e

4
-
w
a
y
ARNU48GTM*2
Discharge angle: 40
Air velocity [m/s]
Temperature [C]
4.0
4.0
3.0
3.0
2.0 2.0
1.0
1.0
Discharge angle: 50
Air velocity [m/s]
Temperature [C]
3.2m
0m
4m 5m 3m 5m 2m 1m 1m 0m
2m
1m
3m 2m 4m
3.2m
0m
4m 5m 3m 5m 2m 1m 1m 0m
2m
1m
3m 2m 4m
3.2m
0m
4m 5m 3m 5m 2m 1m 1m 0m
2m
1m
3m 2m 4m
3.2m
0m
4m 5m 3m 5m 2m 1m 1m 0m
2m
1m
3m 2m 4m
24
33 33
24
27
27
30
30
22 22
4.0 4.0
3.0
3.0
2.0 2.0
1.0 1.0
18 18
20
20
22 22
24 24
Cooling Heating
Indoor unit
Ceiling Cassette 4-way
3-27 3-27
C
a
s
s
e
t
t
e

4
-
w
a
y
8. Electric Characteristicss
Symbols:
MCA : Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor
Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA
MFA 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the larger value on the MCA.
5. Instead of fuse, use Circuit Breaker.
Units
Model Type Hz Volts Voltage Range
ARNU05GTR*2 TR 0.25 15 0.043 0.2 30 30
ARNU07GTR*2 TR 0.25 15 0.043 0.2 30 30
ARNU09GTR*2 TR 0.25 15 0.043 0.2 30 30
ARNU12GTR*2 TR 0.25 15 0.043 0.2 30 30
ARNU15GTQ*2 TQ 0.25 15 0.043 0.2 30 30
ARNU18GTQ*2 TQ 50 220-240
MAX : 264
0.25 15 0.043 0.2 30 30
ARNU24GTP*2 TP
MIN:198
0.22 15 0.03 0.17 33 33
ARNU28GTP*2 TP 0.22 15 0.03 0.17 33 33
ARNU36GTN*2 TN 0.81 15 0.135 0.64 144 144
ARNU42GTM*2 TM 0.81 15 0.135 0.64 144 144
ARNU48GTM*2 TM 0.81 15 0.135 0.64 144 144
ARNU05GTR*2 TR 0.25 15 0.043 0.2 30 30
ARNU07GTR*2 TR 0.25 15 0.043 0.2 30 30
ARNU09GTR*2 TR 0.25 15 0.043 0.2 30 30
ARNU12GTR*2 TR 0.25 15 0.043 0.2 30 30
ARNU15GTQ*2 TQ 0.25 15 0.043 0.2 30 30
ARNU18GTQ*2 TQ 60 220
MAX : 242
0.25 15 0.043 0.2 30 30
ARNU24GTP*2 TP
MIN:198
0.22 15 0.03 0.17 33 33
ARNU28GTP*2 TP 0.22 15 0.03 0.17 33 33
ARNU36GTN*2 TN 0.81 15 0.135 0.64 144 144
ARNU42GTM*2 TM 0.81 15 0.135 0.64 144 144
ARNU48GTM*2 TM 0.81 15 0.135 0.64 144 144
Power Supply IFM Input(W)
MCA MFA kW FLA Cooling Heating
Indoor unit
Ceiling Cassette 4-way
3-28 3-28
C
a
s
s
e
t
t
e

4
-
w
a
y
9. Sound Levels
Overall
Sound Pressure Level
Notes:
- Sound measured at 1.5m below the center of the unit.
- Data is valid at free field condition
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed. 1.5m
Ceiling
ARNU05GTR*2
ARNU07GTR*2
ARNU09GTR*2
ARNU12GTR*2
ARNU15GTQ*2
ARNU18GTQ*2
Sound Level dB(A)
Model
H M L
29
29
30
32
36
37
27
27
29
30
34
35
26
26
27
27
32
34
ARNU24GTP*2
ARNU28GTP*2
ARNU36GTN*2
ARNU42GTM*2
ARNU48GTM*2
Sound Level dB(A)
Model
H M L
ARNU05GTR*2 ARNU07GTR*2 ARNU09GTR*2
36 34 31
39 35 33
43 40 37
44 41 38
46 43 41
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
Indoor unit
Ceiling Cassette 4-way
3-29 3-29
C
a
s
s
e
t
t
e

4
-
w
a
y
ARNU36GTN*2
ARNU18GTQ*2 ARNU15GTQ*2 ARNU12GTR*2
ARNU48GTM*2 ARNU42GTM*2
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
ARNU28GTP*2 ARNU24GTP*2
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
Indoor unit
Ceiling Cassette 4-way
3-30 3-30
C
a
s
s
e
t
t
e

4
-
w
a
y
10. Installation
Please read this instruction sheet completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
Wired Remote Controller(Optional)
Anti-bacteria filter
Air
Intake
Air Outlet
Remote Controller
TEMP
Required Parts Required Tools
Connecting cable
Pipes: Gas side
Liquid side
Hanging Bolt
(W 3/8 or M10 length 650mm)
Insulated drain hose
Additional Drain hose
Level
Screw driver
Electric drill
Hole core drill
Flaring Tool set
Torque Wrenches
Hexagonal Wrench
Gas-leak detector
Thermometer
10.1 Selection of the best location
There should not be any heat source or steam near the
unit.
There should not be any obstacles to the air circula-
tion.
A place where air circulation in the room will be good.
A place where drainage can be easily obtained.
A place where noise prevention is taken into consider-
ation.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall,
ceiling, or other obstacles.
The indoor unit must have sufficient maintenance
space.
Unit:cm
Ceiling
Ceiling Board
Ceiling Board
3
0

o
r

m
o
r
e
A
b
o
v
e

2
5
0
3
6
0

o
r

l
e
s
s
1
0
0

o
r

m
o
r
e
50 or
more
50 or
more 3
0

o
r

l
e
s
s
Floor
Indoor unit
Ceiling Cassette 4-way
3-31 3-31
C
a
s
s
e
t
t
e

4
-
w
a
y
10.2 Ceiling opening dimensions and hanging bolt location
NOTE:
Avoid the following installation location.
1. Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated.
These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function.
In these cases, take the following actions;
Make sure that ventilation fan is enough to cover all noxious gases from this place.
Ensure enough distance from the cooking room to install the air conditioner in such a place where it may not suck oily steam.
Ceiling board
Level gauge
Ceiling
TQ/TR Chassis TM/TN/TP Chassis
Unit:mm
875(Ceiling opening)
787(Hanging bolt)
6
8
4
(
H
a
n
g
i
n
g

b
o
l
t
)
6
7
1
8
7
5
(
C
e
i
l
i
n
g

o
p
e
n
i
n
g
)
840 Unit size
8
4
0

U
n
i
t

s
i
z
e
Unit:mm
585~660(Ceiling opening)
517
461
5
1
7

5
8
5
~
6
6
0
(
C
e
i
l
i
n
g

o
p
e
n
i
n
g
)
5
2
3
570
5
7
0

3
1
9
The dimensions of the paper pattern for installation are the same as those of the ceiling opening dimensions.
Select and mark the position for fixing bolts and pip-
ing hole.
Decide the position for fixing bolts slightly tilted to
the drain direction after considering the direction of
drain hose.
Drill the hole for anchor bolt on the wall.
This air-conditioner uses a drain pump.
Install the unit horizontally using a level gauge.
During the installation, care should be taken not to
damage electric wires.
CAUTION
Use the ventilation fan
for smoke-collecting
hood with sufficient
capacity.
Cooking table
Air conditioner
Take enough
distance
2. Avoid installng air conditioner in such places where cooking oil or iron powder is generated.
3. Avoid places where inflammable gas is generated.
4. Avoid place where noxious gas is generated.
5. Avoid places near high frequency generators.
Indoor unit
Ceiling Cassette 4-way
3-32 3-32
C
a
s
s
e
t
t
e

4
-
w
a
y
Set screw of
paper model (4 pieces)
Paper model
for installation
Ceiling board
1
5
0
m
m
Ceiling board
Ceiling
Flat washer for M10
(accessory)
Keep the length of the bolt
from the bracket to 40mm
Open the ceiling board
along the outer edge of the
paper model
Flat washer for M10
(accessory)
Hanging bolt
(W3/8 or M10)
Nut
(W3/8 or M10)
Nut
(W3/8 or M10)
Air Conditioner body
Keep the length of 15~18mm
between the air conditioner bottom
surface and the ceiling surface
The following parts are locally purchased.
Hanging Bolt - W 3/8 or M10
Nut - W 3/8 or M10
Spring Washer - M10
Plate Washer - M10
Tighten the nut and bolt to prevent the unit
from falling.
CAUTION
Terminal Block Indoor
1(L) 2(N) 3 4
INDOOR POWER INPUT
A - - - - - - B A B
GND 12V DRY2 DRY1 INTERNET IDU SODU Outdoor
Unit
TR/TQ Chassis
Terminal Block Indoor
1(L) 2(N) 4(N) 3(L)
Terminal Block Indoor
5(A) 5(B) YL BK RD
POWER TO AIR
A B A - - - - B A B
GND 12V DRY2 DRY1 INTERNET IDU SODU Outdoor
Unit
TM/TN/TP Chassis
power cord
Indoor cord
Remote
control cord
Make sure that the screws of the terminal are not loose.
WARNING
10.3 Wiring Connection
Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit
respectively.
Indoor unit
Ceiling Cassette 4-way
3-33 3-33
C
a
s
s
e
t
t
e

4
-
w
a
y
10.4 Installation of Decoration Panel
1. Temporarily fix two decoration panel fixing screws (hexagon M5 screw) on the unit body. (Tighten by
amount 10mm in length.)
The fixing screws (hexagon M5 screw) are included in the indoor unit box.
2. Remove the air inlet grille from the decoration panel. (Remove the hook for the air inlet grille cord.)
3. Hook the decoration panel key hole ( ) on the screws fixed in step above, and slide the panel so
that the screws reach the key hole edge.
4. Retighten completely two temporarily fixed screws and other two screws. (Total 4 screws)
5. Connect the louver motor connector and display connector.
6. After tightening these screws, install the air inlet grille (including the air filter).
Decoration panel fixing screws
(hexagon M5 screws)
Temporally fitting at 2 places
(Tightening about 10mm)
Air conditioner unit
Decoration panel
Control box cover
Piping side
Louver motor
Display
Lead wire for
louver motor and
display
Decoration panel fixing screws
(Hexagon M5 screw)
Inlet Grille Inlet Grille
The decoration panel has its installation
direction.
Before installing the decoration panel,
always remove the paper template.
CAUTION
Install certainly the decoration
panel.
Cool air leakage causes
sweating.
Water drops fall.
Air conditioner
unit
Ceiling
board
Decoration panel
Decoration
panel
Fit the insulator (this part) and
be careful for cool air leakage
Good example
Air
Cool air leakage
(no good)
Bad example
Ceiling
board
Air conditioner unit
Indoor unit
Ceiling Cassette 4-way
3-34 3-34
C
a
s
s
e
t
t
e

4
-
w
a
y
10.5 Indoor Unit Drain Piping
Drain piping must have down-slope (1/50 to 1/100): be sure not to pro-
vide up-and-down slope to prevent reversal flow.
During drain piping connection, be careful not to exert extra force on the
drain port on the indoor unit.
The outside diameter of the drain connection on the indoor unit is 32mm.
Be sure to install heat insulation on the drain piping.
Piping material: Polyvinyl chloride pipe inner
diometes 25mm and pipe fittings
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:
Connect the main drain pipe to the exterior and leave it pro-
visionally until the test comes to an end.
Feed water to the flexible drain hose and check the piping
for leakage.
Be sure to check the drain pump for normal operating and
noise when electrical wiring is complete.
When the test is complete, connect the flexible drain hose to
the drain port on the indoor unit.
Heat insulation material: Polyethylene foam with
thickness more than 8 mm.
Drain test
Maintenance
drain port
Upward
routing
not allowed
Pipe clamp
Indoor unit
1/50~1/100
MAX 700mm
Feed water
Drain Pump
Drain pan
Flexible drain hose
(accessory)
Main
drain pipe
Glue the joint
Drain
port
Drain hose connection
Use the clip (accessory)
CAUTION
The supplied flexible drain hose should not be strained.
A strained hose may cause leakage of water.
1/50~1/100 slope
Hanger
distance
Hanger Bracket
M
a
x

7
0
0
m
m
Flexible drain hose
Insulation
Metal
clamp
Max 300mm
1~15m
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have separate power specially for the air conditioner. As for the method of wiring, follow the circuit diagram pasted on the inside of
control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during
the course of transportation. Check them and make sure that they are all tightly fastened. (If they are loose, it could give rise to burn-out of the
wires.)
4) Confirm the specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Do not install the leakage breaker in a place which is wet or moist.
Water or moist may cause short circuit.
9) The following troubles would be caused by voltage drop-down.
Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the normal function of a overload protection device.
Proper starting power is not given to the compressor.
CAUTION
HAND OVER
Teach the customer the operation and maintenance procedures, using the operation manual (air filter cleaning, temperature control, etc.).
Indoor unit
Ceiling Cassette 4-way
3-35 3-35
C
a
s
s
e
t
t
e

4
-
w
a
y
WIRED REMOTE CONTROLLER INSTALLATION
Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average tempera-
ture.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
Fig.1 Typical locations for remote controller
5feet
(1.5meters)
no
no
no
yes
Remote Controller
TEMP
Remote Controller
TEMP
Remote Controller
TEMP
Indoor unit
Ceiling Cassette 4-way
3-36 3-36
C
a
s
s
e
t
t
e

4
-
w
a
y
11. Accessories
Name
Quantity
Shape
for gas pipe
for liquid pipe
Clamp metal
2 EA
Insulation for
fitting
1 SET
Drain hose
1 EA
Clamp
(Tie Wrap)
8 EA
Washer for
hanging backet
4 EA
(Other)
Standard Accessories
Paper pattern for
installation
Owner's manual
Installation manual
Bolt
4 EA
Use only those accessories (Standard or optional) which have designated specifications.
CAUTION
Indoor unit
Ceiling Concealed Duct
- High Static
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
1. List of functions
2. Specifications
3. Dimensions & Gravity point
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. External Static Pressure(E.S.P) & Air Flow
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories
Ceiling Concealed Duct
(High Static)
Indoor unit
Ceiling Concealed Duct
- High Static
4-1 4-1
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
1. List of functions
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Air flow
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Air purifying Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
Installation
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Reliability Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Convenience Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Individual Simple wired remote controller
control Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Special
Zone control
function kit
CTIE
Electro thermostat
1
-
-
-
-
3 / 3 / 3
-
-
-
-
X
X
O
O
O
X
-
O
O
O
O(Heat recovery)
X
O(Heat pump or Cooling only)
O
O
-
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
X
Accessory
Accessory
-
-
Function
Category
ARNU07GBHA2, ARNU09GBHA2, ARNU12GBHA2, ARNU15GBHA2,
ARNU18GBHA2, ARNU24GBHA2, ARNU28GBGA2 , ARNU36GBGA2,
ARNU42GBGA2, ARNU48GBRA2, URNU76GB8A2, URNU96GB8A2
O : Applied X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.
Indoor unit
Ceiling Concealed Duct
- High Static
4-2 4-2
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
2. Specifications
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Noise Level is Standard Mode
(for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dB(A))
7. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Air Flow Rate(H / M / L) CMM
(High Mode-factory set) cfm
Fan External Static Pressure mmAq(Pa)
Air Flow Rate(H / M / L) CMM
(Standard Mode) cfm
External Static Pressure mmAq(Pa)
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Ceiling Concealed Duct -High Static
ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA2
2.2 2.8 3.6 4.5
1,900 2,400 3,100 3,900
7,500 9,600 12,300 15,400
2.5 3.2 4.0 5.0
2,200 2,800 3,400 4,300
8,500 10,900 13,600 17,100
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
882 x 450 x 260 882 x 450 x 260 882 x 450 x 260 882 x 450 x 260
34.7 x 17.7 x 10.2 34.7 x 17.7 x 10.2 34.7 x 17.7 x 10.2 34.7 x 17.7 x 10.2
2 x 10 x 21 2 x 10 x 21 2 x 10 x 21 2 x 10 x 21
0.15 0.15 0.15 0.15
Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan
118 118 118 118
0.92 0.92 0.92 0.92
8.5 / 7.5 / 6.0 10.0 / 8.5 / 7.5 12.0 / 10.0 / 8.5 13.5 / 12.0 / 8.5
300 / 265 / 212 353 / 300 / 265 424 / 353 / 300 477 / 424 / 300
8(78) 8(78) 8(78) 8(78)
8.5 / 8.0 / 7.5 8.5 / 8.0 / 7.5 11.0 / 8.5 / 7.5 13.5 / 12.0 / 11.0
300 / 282 / 265 300 / 282 / 265 388 / 300 / 265 477 / 424 / 388
6(59) 6(59) 6(59) 6(59)
Direct Direct Direct Direct
BLDC BLDC BLDC BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene Foamed polystrene
- - - -
Fuse Fuse Fuse Fuse
6.35(1/4) 6.35(1/4) 6.35(1/4) 6.35(1/4)
12.7(1/2) 12.7(1/2) 12.7(1/2) 12.7(1/2)
25(1) 25(1) 25(1) 25(1)
26(57.4) 26(57.4) 26(57.4) 26(57.4)
34 / 33 / 32 35 / 34 / 33 37 / 35 / 34 39 / 38 / 37
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Indoor unit
Ceiling Concealed Duct
- High Static
4-3 4-3
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Noise Level is Standard Mode
(for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dB(A))
7. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Air Flow Rate(H / M / L) CMM
(High Mode-factory set) cfm
Fan External Static Pressure mmAq(Pa)
Air Flow Rate(H / M / L) CMM
(Standard Mode) cfm
External Static Pressure mmAq(Pa)
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Ceiling Concealed Duct(High Static)
ARNU18GBHA2 ARNU24GBHA2 ARNU28GBGA2
5.6 7.1 8.2
4,800 6,100 7,100
19,100 24,200 28,000
6.3 8.0 9.2
5,400 6,900 8,000
21,500 27,300 31,500
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
882 x 450 x 260 882 x 450 x 260 1,182 x 450 x 298
34.7 x 17.7 x 10.2 34.7 x 17.7 x 10.2 46.5 x 17.7 x 11.7
3 x 10 x 21 3 x 10 x 21 3 x 12 x 21
0.15 0.15 0.26
Sirocco Fan Sirocco Fan Sirocco Fan
118 118 390
0.92 0.92 2.30
15.5 / 13.5 / 12.4 18.3 / 16.9 / 15.5 25.9 / 24.1 / 21.8
547 / 477 / 438 646 / 597 / 547 915 / 851 / 770
8(78) 8(78) 10(98)
15.3 / 13.6 / 10.3 19.0 / 16.4 / 14.5 25.3 / 21.8 / 17.6
540 / 480 / 364 671 / 579 / 512 893 / 770 / 622
6(59) 6(59) 8(78)
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene
- - -
Fuse Fuse Fuse
6.35(1/4) 9.52(3/8) 9.52(3/8)
12.7(1/2) 15.88(5/8) 15.88(5/8)
25(1) 25(1) 25(1)
26.5(58.4) 26.5(58.4) 38.0(83.8)
42.5 / 41 / 37 45 / 43 / 41 44 / 42 / 40
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Indoor unit
Ceiling Concealed Duct
- High Static
4-4 4-4
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Noise Level is Standard Mode
(for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dB(A))
7. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Air Flow Rate(H / M / L) CMM
(High Mode-factory set) cfm
Fan External Static Pressure mmAq(Pa)
Air Flow Rate(H / M / L) CMM
(Standard Mode) cfm
External Static Pressure mmAq(Pa)
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
ARNU36GBGA2
10.6
9,100
36,200
11.9
10,200
40,600
Galvanized Steel Plate
1,182 x 450 x 298
46.5 x 17.7 x 11.7
3 x 12 x 21
0.26
Sirocco Fan
390
2.30
32.3 / 29.0 / 25.3
1,141 / 1,024 / 894
10(98)
28.4 / 25.3 / 21.8
1,003 / 894 / 770
8(78)
Direct
BLDC
Microprocessor, Thermostat for cooling and heating
Foamed polystrene
-
Fuse
9.52(3/8)
15.88(5/8)
25(1)
38(83.8)
46 / 44 / 42
1, 220-240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C
ARNU42GBGA2 ARNU48GBRA2
12.3 14.1
10,600 12,100
42,000 48,100
13.8 15.9
11,000 13,200
43,800 51,200
Galvanized Steel Plate Galvanized Steel Plate
1,182 x 450 x 298 1,230 x 590 x 380
46.5 x 17.7 x 11.7 48.4 x 23.2 x 15
3 x 12 x 21 3 x 13 x 19
0.26 0.38
Sirocco Fan Sirocco Fan
390 390
2.30 2.40
34.5 / 32.3 / 30.7 44.8 / 40.6 / 33.3
1,218 / 1,141 / 1,084 1,582 / 1,434 / 1,176
10(98) 14(137)
32.0 / 28.4 / 27.2 44.4 / 39.5 / 33.5
1,130 / 1,003 / 961 1,568 / 1,395 / 1,183
8(78) 10(98)
Direct Direct
BLDC BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene
- -
Fuse Fuse
9.52(3/8) 9.52(3/8)
15.88(5/8) 15.88(5/8)
25(1) 25(1)
38(83.8) 53(117)
48 / 46 / 45 45 / 43 / 41
1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60
EEV EEV
CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Ceiling Concealed Duct(High Static)
Indoor unit
Ceiling Concealed Duct
- High Static
4-5 4-5
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Noise Level is Standard Mode
(for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dB(A))
7. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Air Flow Rate(H / M / L) CMM
(High Mode-factory set) cfm
Fan External Static Pressure mmAq(Pa)
Air Flow Rate(H / M / L) CMM
(Standard Mode) cfm
External Static Pressure mmAq(Pa)
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Ceiling Concealed Duct(High Static)
URNU76GB8A2 URNU96GB8A2
22.4 28
19,300 24,100
76,400 95,900
25.2 31.5
21,700 27,100
86,000 107,500
Galvanized Steel Plate Galvanized Steel Plate
1,562 x 688 x 460 1,562 x 688 x 460
61.5 x 27.1 x 18.1 61.5 x 27.1 x 18.1
3 x 21 x 19 3 x 21 x 19
0.59 0.59
Sirocco Fan Sirocco Fan
375 x 2 375 x 2
4.50 4.50
60.0 / 50.0 / 50.0 72.0 / 64.0 / 64.0
2,119 / 1,766 / 1,766 2542 / 2,260 / 2,260
22(216) 22(216)
64.0 / 50.0 / 50.0 76.0 / 64.0 / 64.0
2,260 / 1,766 / 1,766 2,684 / 2,260 / 2,260
15(147) 15(147)
Direct Direct
BLDC BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene
- -
Fuse Fuse
9.52(3/8) 9.52(3/8)
19.05(3/4) 22.2(7/8)
25(1) 25(1)
87(192) 87(192)
50 / 48 / 48 52 / 50 / 50
1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60
EEV EEV
CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Indoor unit
Ceiling Concealed Duct
- High Static
4-6 4-6
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
3. Dimensions & Gravity point
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

B
H
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t

(
H
i
g
h

S
t
a
t
i
c
)
A
R
N
U
0
7
G
B
H
A
2
A
R
N
U
0
9
G
B
H
A
2
A
R
N
U
1
2
G
B
H
A
2
A
R
N
U
1
5
G
B
H
A
2
A
R
N
U
1
8
G
B
H
A
2
A
R
N
U
2
4
G
B
H
A
2
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
4
8
5
2
1
6
5
1
4
0
1
2
3
1
0
1
3
1
5
1
2
9
7
0
5
0
1
0
0
2
6
0
8
7
7
5
0
3
0
4
7
3 5 5
4 5 0
2 1 9
9
3
2
1 3 3
3 5 5
4 5 0
1
1
4
2 2 4
6
0
R
3
7
.
5
4
7
4
9
2
4
2
1
8
8
2
8
8
2
1 5 8
2 6 0
4 5 0
6
5
1
0
8
6
4
2
4
3
2
1
2
2
4
3
1
1
9
7
5
1
1
5
7
4
5
2 0
1 7 5
N
a
m
e

1

L
i
q
u
i
d

p
i
p
e

c
o
n
n
e
c
t
i
o
n

2

G
a
s

p
i
p
e

c
o
n
n
e
c
t
i
o
n


3

D
r
a
i
n

p
i
p
e

c
o
n
n
e
c
t
i
o
n


4

P
o
w
e
r

s
u
p
p
l
y

c
o
n
n
e
c
t
i
o
n


5

A
i
r

d
i
s
c
h
a
r
g
e


6

A
i
r

s
u
c
t
i
o
n
N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
(
u
n
i
t

:

m
m
)
U
n
i
t

s
i
z
e
(
7
k
,
9
k
,
1
2
k
,
1
8
k
)
:

6
.
3
5
U
n
i
t

s
i
z
e
(
2
4
k
)
:

9
.
5
2
U
n
i
t

s
i
z
e
(
7
k
,
9
k
,
1
2
k
,
1
8
k
)
:

1
2
.
7
U
n
i
t

s
i
z
e
(
2
4
k
)
:

1
5
.
8
8
3
2
5
1
4
6
G
r
a
v
i
t
y

p
o
i
n
t
1 1 9
4
2
8
1 0 6 1 2 7
Indoor unit
Ceiling Concealed Duct
- High Static
4-7 4-7
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

B
G
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t

(
H
i
g
h

S
t
a
t
i
c
)
A
R
N
U
2
8
G
B
G
A
2

A
R
N
U
3
6
G
B
G
A
2
A
R
N
U
4
2
G
B
G
A
2
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
2
6
1
1
2
2
1
4
0
4
7
5
3
1
6
5
3
2
5
1
1
0
2
5
0
1
0
0
8
7
8
3
0
2
9
7
5
3 5 5
8
7
1
,
2
3
0
4 5 0
2
3
4
9
1
0
8
1
,
1
8
2
1 5 81 1 3
2 9 8
1 8 6
2
3
2
2
4
3
2
4
3
2
3
2
2
3
2
1
1
5
1
,
0
4
3
2 0
2 2 0
3
2
5
1
4
6
N
a
m
e

1

L
i
q
u
i
d

p
i
p
e

c
o
n
n
e
c
t
i
o
n

U
n
i
t

s
i
z
e
(
2
8
k
,
3
6
k
,
4
2
k
)
:

9
.
5
2

2

G
a
s

p
i
p
e

c
o
n
n
e
c
t
i
o
n

U
n
i
t

s
i
z
e
(
2
8
k
,
3
6
k
,
4
2
k
)
:

1
5
.
8
8


3

D
r
a
i
n

p
i
p
e

c
o
n
n
e
c
t
i
o
n


4

P
o
w
e
r

s
u
p
p
l
y

c
o
n
n
e
c
t
i
o
n


5

A
i
r

d
i
s
c
h
a
r
g
e


6

A
i
r

s
u
c
t
i
o
n

N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
(
u
n
i
t

:

m
m
)
1
5
2
2 2 4
6
0

1
0
0
1
,
1
8
2
4 5 0
G
r
a
v
i
t
y

p
o
i
n
t
2 1 9
1 3 6
5
6
5
Indoor unit
Ceiling Concealed Duct
- High Static
4-8 4-8
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

B
R
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t

(
H
i
g
h

S
t
a
t
i
c
)
A
R
N
U
4
8
G
B
R
A
2
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
2 2 1
1 2 3
7 2
2
6
8
3
1
0
1
9 0
1
3
5
1 2 2
1 4 4
2
6
0
1
9
0
1
1
5
1
,
2
8
4
4 7 75 6
5 9 0
1
1
81
,
0
0
4
1
1
4
1
,
2
3
0
5
0
3 2
1 6 81 8 5
2
1
5
2
7
9
2
4
1
2
7
9
3 8 0
1 4 0
2
1
5 1
2
0
1
,
0
9
2
2 5
3 0 3
N
a
m
e

1

L
i
q
u
i
d

p
i
p
e

c
o
n
n
e
c
t
i
o
n

U
n
i
t

s
i
z
e
(
4
8
k
)
:

9
.
5
2

2

G
a
s

p
i
p
e

c
o
n
n
e
c
t
i
o
n

U
n
i
t

s
i
z
e
(
4
8
k
)
:

1
5
.
8
8


3

D
r
a
i
n

p
i
p
e

c
o
n
n
e
c
t
i
o
n


4

P
o
w
e
r

s
u
p
p
l
y

c
o
n
n
e
c
t
i
o
n


5

A
i
r

d
i
s
c
h
a
r
g
e


6

A
i
r

s
u
c
t
i
o
n

N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
(
u
n
i
t

:

m
m
)
3
2
1
5
6
4
1
9
8
3 1 2
6
0
R
6
0
5 9 0
1
,
2
3
0
G
r
a
v
i
t
y

p
o
i
n
t
3 0 2
1 7 4
6
2
1
Indoor unit
Ceiling Concealed Duct
- High Static
4-9 4-9
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

B
8
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t

(
H
i
g
h

S
t
a
t
i
c
)
U
R
N
U
7
6
G
B
8
A
2
U
R
N
U
9
6
G
B
8
A
2
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
1
,
5
6
2
1
,
6
2
2
4
6
0
6 8 8
5 6 06 4
3 0

1
,
2
2
0


1
,
5
6
2
3
2
9
3
2
0
3
2
9
3 1 8
2
9
3

4 6 0
6 8 8
2 9 01 6 1
7
0
1
2
0
9
9
1
4
0
4 4 0
2 0
1
,
3
9
6
1
1
5
N
a
m
e

1

L
i
q
u
i
d

p
i
p
e

c
o
n
n
e
c
t
i
o
n

2

G
a
s

p
i
p
e

c
o
n
n
e
c
t
i
o
n


3

D
r
a
i
n

p
i
p
e

c
o
n
n
e
c
t
i
o
n


4

P
o
w
e
r

s
u
p
p
l
y

c
o
n
n
e
c
t
i
o
n


5

A
i
r

d
i
s
c
h
a
r
g
e


6

A
i
r

s
u
c
t
i
o
n
N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
(
u
n
i
t

:

m
m
)
U
n
i
t

s
i
z
e
(
7
6
k
,
9
6
k
)
:

9
.
5
2
U
n
i
t

s
i
z
e
(
7
6
k
)
:

1
9
.
0
5
U
n
i
t

s
i
z
e
(
9
6
k
)
:

2
2
.
2
3
2
1
4
5
6
6 47 06 01 2 2
3
5
8
1
0
9
6
8
1
8
5
8
G
r
a
v
i
t
y

p
o
i
n
t
3 9 7
2 2 2
8
1
9
Indoor unit
Ceiling Concealed Duct
- High Static
4-10 4-10
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
4. Piping Diagrams
Heat Exchanger
Sirocco Fan
Th3
Th1
Th2
lndoor unit
EEV
:Heating
:Cooling
Filter
Filter
Refrigerant pipe connection port diameter
MODEL GAS LIQUID
ARNU07GBHA2 12.7(1/2) 6.35(1/4)
ARNU09GBHA2 12.7(1/2) 6.35(1/4)
ARNU12GBHA2 12.7(1/2) 6.35(1/4)
ARNU15GBHA2 12.7(1/2) 6.35(1/4)
ARNU18GBHA2 12.7(1/2) 6.35(1/4)
ARNU24GBHA2 15.88(5/8) 9.52(3/8)
ARNU28GBGA2 15.88(5/8) 9.52(3/8)
ARNU36GBGA2 15.88(5/8) 9.52(3/8)
ARNU42GBGA2 15.88(5/8) 9.52(3/8)
ARNU48GBRA2 15.88(5/8) 9.52(3/8)
URNU76GB8A2 19.05(3/4) 9.52(3/8)
URNU96GB8A2 22.2(7/8) 9.52(3/8)
[Unit: mm(inch)]
LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor
Indoor unit
Ceiling Concealed Duct
- High Static
4-11 4-11
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
5. Wiring Diagrams
BH Chassis
CONNECTOR NUMBER LOCATION POINT FUNCTION
CN-POWER AC Power supply AC Power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC output for drain pump
CN-COM Communication Connection between indoor and outdoor
CN-EEV EEV Output EEV Control output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room air thermistor
CN-REMO Remote controller Remote control line
CN-ZON Zontroller Zone control line
CN-DISPLAY RF Remote controller RF Remote control line
CN-CC Dry contact Dry contact line
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor
CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.
Indoor unit
Ceiling Concealed Duct
- High Static
4-12 4-12
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
BG Chassis
CONNECTOR NUMBER LOCATION POINT FUNCTION
CN-POWER AC Power supply AC Power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC output for drain pump
CN-COM Communication Connection between indoor and outdoor
CN-EEV EEV Output EEV Control output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room air thermistor
CN-REMO Remote controller Remote control line
CN-ZON Zontroller Zone control line
CN-DISPLAY RF Remote controller RF Remote control line
CN-CC Dry contact Dry contact line
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor
CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.
Indoor unit
Ceiling Concealed Duct
- High Static
4-13 4-13
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
BR Chassis
CONNECTOR NUMBER LOCATION POINT FUNCTION
CN-POWER AC Power supply AC Power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC output for drain pump
CN-COM Communication Connection between indoor and outdoor
CN-EEV EEV Output EEV Control output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room air thermistor
CN-REMO Remote controller Remote control line
CN-ZON Zontroller Zone control line
CN-DISPLAY RF Remote controller RF Remote control line
CN-CC Dry contact Dry contact line
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor
CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.
Indoor unit
Ceiling Concealed Duct
- High Static
4-14 4-14
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
B8 Chassis
CONNECTOR NUMBER LOCATION POINT FUNCTION
CN-POWER AC Power supply AC Power line input for indoor controller
CN-MOTOR1, CN-MOTOR2 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC Output for drain pump
CN-COM Communication Connection between indoor and outdoor
CN-EEV EEV Output EEV Control output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room thermistor
CN-REMO Remote controller Remote control line
CN-CC Dry contact Dry contact line
CN-DISPLAY RF Remocon RF Remocon receiver
CN-OPTION Option PCB Option PCB connector
CN-ZONE Zone controller Zone controller line
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor
CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.
Indoor unit
Ceiling Concealed Duct
- High Static
4-15 4-15
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
6. Capacity Tables
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 2.4 2.3 2.9 2.5 3.4 2.7 3.6 2.8 3.8 2.9 4.3 3.0 4.7 3.0
12 2.4 2.3 2.9 2.5 3.4 2.7 3.6 2.8 3.8 2.9 4.3 3.0 4.7 2.9
14 2.4 2.3 2.9 2.5 3.4 2.7 3.6 2.8 3.8 2.9 4.3 3.0 4.6 2.9
16 2.4 2.3 2.9 2.5 3.4 2.7 3.6 2.8 3.8 2.9 4.3 3.0 4.6 2.8
18 2.4 2.3 2.9 2.5 3.4 2.7 3.6 2.8 3.8 2.9 4.3 3.0 4.5 2.8
20 2.4 2.3 2.9 2.5 3.4 2.7 3.6 2.8 3.8 2.9 4.3 3.0 4.4 2.8
21 2.4 2.3 2.9 2.5 3.4 2.7 3.6 2.8 3.8 2.9 4.3 3.0 4.4 2.7
23 2.4 2.3 2.9 2.5 3.4 2.7 3.6 2.8 3.8 2.9 4.3 3.0 4.3 2.7
25 2.4 2.3 2.9 2.5 3.4 2.7 3.6 2.8 3.8 2.9 4.3 3.0 4.3 2.7
27 2.4 2.3 2.9 2.5 3.4 2.7 3.6 2.8 3.8 2.9 4.3 3.0 4.2 2.6
29 2.4 2.3 2.9 2.5 3.4 2.7 3.6 2.8 3.8 2.9 4.3 3.0 4.2 2.6
31 2.4 2.3 2.9 2.5 3.4 2.7 3.6 2.8 3.8 2.9 4.3 3.0 4.1 2.6
33 2.4 2.3 2.9 2.5 3.4 2.7 3.6 2.8 3.8 2.9 4.3 3.0 4.0 2.5
35 2.4 2.3 2.9 2.5 3.4 2.7 3.6 2.8 3.8 2.9 4.3 3.0 4.0 2.5
37 2.4 2.3 2.9 2.5 3.4 2.7 3.6 2.8 3.8 2.9 4.3 3.0 3.9 2.4
39 2.4 2.3 2.9 2.5 3.4 2.7 3.6 2.8 3.8 2.9 4.3 3.0 3.8 2.4
2.8
3.6
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
10 1.5 1.4 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.7 2.6 1.8 2.9 1.8
12 1.5 1.4 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.7 2.6 1.8 2.9 1.8
14 1.5 1.4 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.7 2.6 1.8 2.8 1.8
16 1.5 1.4 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.7 2.6 1.8 2.8 1.7
18 1.5 1.4 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.7 2.6 1.8 2.7 1.7
20 1.5 1.4 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.7 2.6 1.8 2.7 1.7
21 1.5 1.4 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.7 2.6 1.8 2.7 1.7
23 1.5 1.4 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.7 2.6 1.8 2.6 1.7
25 1.5 1.4 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.7 2.6 1.8 2.6 1.6
27 1.5 1.4 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.7 2.6 1.8 2.6 1.6
29 1.5 1.4 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.7 2.6 1.8 2.5 1.6
31 1.5 1.4 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.7 2.6 1.8 2.5 1.6
33 1.5 1.4 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.7 2.6 1.8 2.5 1.5
35 1.5 1.4 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.7 2.6 1.8 2.4 1.5
37 1.5 1.4 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.7 2.6 1.8 2.4 1.5
39 1.5 1.4 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.7 2.6 1.8 2.3 1.5
10 1.9 1.8 2.3 2.0 2.6 2.1 2.8 2.2 3.0 2.2 3.4 2.3 3.7 2.3
12 1.9 1.8 2.3 2.0 2.6 2.1 2.8 2.2 3.0 2.2 3.4 2.3 3.6 2.3
14 1.9 1.8 2.3 2.0 2.6 2.1 2.8 2.2 3.0 2.2 3.4 2.3 3.6 2.2
16 1.9 1.8 2.3 2.0 2.6 2.1 2.8 2.2 3.0 2.2 3.4 2.3 3.5 2.2
18 1.9 1.8 2.3 2.0 2.6 2.1 2.8 2.2 3.0 2.2 3.4 2.3 3.5 2.2
20 1.9 1.8 2.3 2.0 2.6 2.1 2.8 2.2 3.0 2.2 3.4 2.3 3.4 2.1
21 1.9 1.8 2.3 2.0 2.6 2.1 2.8 2.2 3.0 2.2 3.4 2.3 3.4 2.1
23 1.9 1.8 2.3 2.0 2.6 2.1 2.8 2.2 3.0 2.2 3.4 2.3 3.4 2.1
25 1.9 1.8 2.3 2.0 2.6 2.1 2.8 2.2 3.0 2.2 3.4 2.3 3.3 2.1
27 1.9 1.8 2.3 2.0 2.6 2.1 2.8 2.2 3.0 2.2 3.4 2.3 3.3 2.0
29 1.9 1.8 2.3 2.0 2.6 2.1 2.8 2.2 3.0 2.2 3.4 2.3 3.2 2.0
31 1.9 1.8 2.3 2.0 2.6 2.1 2.8 2.2 3.0 2.2 3.4 2.3 3.2 2.0
33 1.9 1.8 2.3 2.0 2.6 2.1 2.8 2.2 3.0 2.2 3.4 2.3 3.1 2.0
35 1.9 1.8 2.3 2.0 2.6 2.1 2.8 2.2 3.0 2.2 3.4 2.3 3.1 1.9
37 1.9 1.8 2.3 2.0 2.6 2.1 2.8 2.2 3.0 2.2 3.4 2.3 3.0 1.9
39 1.9 1.8 2.3 2.0 2.6 2.1 2.8 2.2 3.0 2.2 3.4 2.3 3.0 1.9
2.2
6.1 Cooling Capacity
Cooling capacity
Indoor unit
Ceiling Concealed Duct
- High Static
4-16 4-16
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.3 5.5
12 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.2 5.5
14 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.1 5.4
16 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.0 5.3
18 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.8 5.2
20 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.7 5.2
21 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.7 5.1
23 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.5 5.1
25 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.4 5.5 8.4 5.0
27 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.2 5.4 8.3 4.9
29 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.1 5.3 8.2 4.8
31 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.0 5.2 8.1 4.8
33 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 7.8 5.1 7.9 4.7
35 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 7.7 5.0 7.8 4.6
37 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.4 5.2 7.5 4.9 7.7 4.6
39 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.2 5.1 7.4 4.8 7.6 4.5
5.6
7.1
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
10 3.0 2.8 3.6 3.1 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.7 5.9 3.7
12 3.0 2.8 3.6 3.1 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.7 5.8 3.6
14 3.0 2.8 3.6 3.1 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.7 5.8 3.6
16 3.0 2.8 3.6 3.1 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.7 5.7 3.6
18 3.0 2.8 3.6 3.1 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.7 5.6 3.5
20 3.0 2.8 3.6 3.1 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.7 5.5 3.5
21 3.0 2.8 3.6 3.1 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.7 5.5 3.4
23 3.0 2.8 3.6 3.1 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.7 5.4 3.4
25 3.0 2.8 3.6 3.1 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.7 5.3 3.3
27 3.0 2.8 3.6 3.1 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.7 5.3 3.3
29 3.0 2.8 3.6 3.1 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.7 5.2 3.2
31 3.0 2.8 3.6 3.1 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.7 5.1 3.2
33 3.0 2.8 3.6 3.1 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.7 5.0 3.1
35 3.0 2.8 3.6 3.1 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.7 5.0 3.1
37 3.0 2.8 3.6 3.1 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.7 4.9 3.1
39 3.0 2.8 3.6 3.1 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.7 4.8 3.0
10 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.4 4.4
12 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.3 4.3
14 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.2 4.3
16 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.1 4.2
18 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.0 4.1
20 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 6.9 4.1
21 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 6.8 4.1
23 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 6.7 4.0
25 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.6 4.3 6.6 3.9
27 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.4 4.2 6.6 3.9
29 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.4 4.2 6.5 3.8
31 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.3 4.1 6.4 3.8
33 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.2 4.0 6.3 3.7
35 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.0 4.0 6.2 3.6
37 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 5.8 4.1 5.9 3.9 6.1 3.6
39 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 5.7 4.0 5.8 3.8 6.0 3.5
4.5
Cooling capacity
Indoor unit
Ceiling Concealed Duct
- High Static
4-17 4-17
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 16.2 9.7
12 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 15.9 9.6
14 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 15.8 9.5
16 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 15.6 9.3
18 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 15.3 9.2
20 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 15.1 9.1
21 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 15.0 9.0
23 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 14.8 8.9
25 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.5 9.7 14.6 8.8
27 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.1 9.4 14.4 8.6
29 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.0 9.3 14.2 8.5
31 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 13.8 9.2 14.0 8.4
33 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 13.5 9.0 13.7 8.3
35 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 13.3 8.8 13.5 8.1
37 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 12.8 9.2 13.0 8.7 13.4 8.0
39 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 12.5 9.0 12.8 8.5 13.1 7.9
10.6
12.3
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
10 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.8 6.5
12 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.6 6.4
14 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.5 6.3
16 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.4 6.2
18 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.2 6.1
20 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.1 6.0
21 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.0 6.0
23 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 9.9 5.9
25 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.7 6.4 9.7 5.8
27 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.4 6.3 9.6 5.8
29 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.3 6.2 9.5 5.7
31 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.2 6.1 9.3 5.6
33 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.0 6.0 9.2 5.5
35 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 8.9 5.9 9.0 5.4
37 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.5 6.1 8.7 5.8 8.9 5.3
39 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.4 6.0 8.5 5.7 8.8 5.3
10 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 13.9 8.4
12 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 13.7 8.2
14 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 13.6 8.2
16 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 13.4 8.0
18 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 13.2 7.9
20 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 13.0 7.8
21 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 12.9 7.8
23 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 12.8 7.7
25 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.5 8.3 12.6 7.5
27 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.2 8.1 12.4 7.5
29 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.1 8.0 12.2 7.3
31 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 11.9 7.9 12.0 7.2
33 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 11.7 7.8 11.8 7.1
35 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 11.4 7.6 11.7 7.0
37 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.0 7.9 11.2 7.5 11.5 6.9
39 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 10.8 7.7 11.0 7.3 11.3 6.8
8.2
Cooling capacity
Indoor unit
Ceiling Concealed Duct
- High Static
4-18 4-18
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
Cooling capacity
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 18.9 16.1 22.5 17.8 26.2 19.3 28.0 19.6 29.8 20.2 33.5 21.1 36.8 20.9
12 18.9 16.1 22.5 17.8 26.2 19.3 28.0 19.6 29.8 20.2 33.5 21.1 36.3 20.6
14 18.9 16.1 22.5 17.8 26.2 19.3 28.0 19.6 29.8 20.2 33.5 21.1 35.9 20.4
16 18.9 16.1 22.5 17.8 26.2 19.3 28.0 19.6 29.8 20.2 33.5 21.1 35.4 20.1
18 18.9 16.1 22.5 17.8 26.2 19.3 28.0 19.6 29.8 20.2 33.5 21.1 34.9 19.8
20 18.9 16.1 22.5 17.8 26.2 19.3 28.0 19.6 29.8 20.2 33.5 21.1 34.4 19.5
21 18.9 16.1 22.5 17.8 26.2 19.3 28.0 19.6 29.8 20.2 33.5 21.1 34.2 19.4
23 18.9 16.1 22.5 17.8 26.2 19.3 28.0 19.6 29.8 20.2 33.5 21.1 33.7 19.1
25 18.9 16.1 22.5 17.8 26.2 19.3 28.0 19.6 29.8 20.2 33.5 21.1 33.2 18.9
27 18.9 16.1 22.5 17.8 26.2 19.3 28.0 19.6 29.8 20.2 33.5 21.1 32.8 18.6
29 18.9 16.1 22.5 17.8 26.2 19.3 28.0 19.6 29.8 20.2 33.5 21.1 32.3 18.3
31 18.9 16.1 22.5 17.8 26.2 19.3 28.0 19.6 29.8 20.2 33.5 21.1 31.8 18.1
33 18.9 16.1 22.5 17.8 26.2 19.3 28.0 19.6 29.8 20.2 33.5 21.1 31.3 17.8
35 18.9 16.1 22.5 17.8 26.2 19.3 28.0 19.6 29.8 20.2 33.5 21.1 30.8 17.5
37 18.9 16.1 22.5 17.8 26.2 19.3 28.0 19.6 29.8 20.2 33.5 21.1 30.4 17.3
39 18.9 16.1 22.5 17.8 26.2 19.3 28.0 19.6 29.8 20.2 33.5 21.1 29.9 17.0
22.4
28.0
10 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.9 11.4 18.5 11.3
12 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.9 11.4 18.3 11.1
14 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.9 11.4 18.1 11.0
16 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.9 11.4 17.8 10.8
18 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.9 11.4 17.6 10.7
20 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.9 11.4 17.3 10.5
21 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.9 11.4 17.2 10.5
23 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.9 11.4 17.0 10.3
25 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.6 11.2 16.7 10.2
27 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.2 10.9 16.5 10.0
29 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.1 10.8 16.3 9.9
31 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 15.8 10.7 16.0 9.7
33 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 15.5 10.5 15.8 9.6
35 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 15.2 10.3 15.5 9.4
37 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 14.7 10.6 14.9 10.1 15.3 9.3
39 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 14.4 10.4 14.7 9.9 15.1 9.2
10 15.1 12.9 18.0 14.3 21.0 15.5 22.4 15.7 23.8 16.1 26.8 16.9 29.4 16.7
12 15.1 12.9 18.0 14.3 21.0 15.5 22.4 15.7 23.8 16.1 26.8 16.9 29.0 16.5
14 15.1 12.9 18.0 14.3 21.0 15.5 22.4 15.7 23.8 16.1 26.8 16.9 28.7 16.3
16 15.1 12.9 18.0 14.3 21.0 15.5 22.4 15.7 23.8 16.1 26.8 16.9 28.3 16.1
18 15.1 12.9 18.0 14.3 21.0 15.5 22.4 15.7 23.8 16.1 26.8 16.9 27.9 15.9
20 15.1 12.9 18.0 14.3 21.0 15.5 22.4 15.7 23.8 16.1 26.8 16.9 27.5 15.6
21 15.1 12.9 18.0 14.3 21.0 15.5 22.4 15.7 23.8 16.1 26.8 16.9 27.4 15.5
23 15.1 12.9 18.0 14.3 21.0 15.5 22.4 15.7 23.8 16.1 26.8 16.9 27.0 15.3
25 15.1 12.9 18.0 14.3 21.0 15.5 22.4 15.7 23.8 16.1 26.8 16.9 26.6 15.1
27 15.1 12.9 18.0 14.3 21.0 15.5 22.4 15.7 23.8 16.1 26.8 16.9 26.2 14.9
29 15.1 12.9 18.0 14.3 21.0 15.5 22.4 15.7 23.8 16.1 26.8 16.9 25.8 14.7
31 15.1 12.9 18.0 14.3 21.0 15.5 22.4 15.7 23.8 16.1 26.8 16.9 25.4 14.4
33 15.1 12.9 18.0 14.3 21.0 15.5 22.4 15.7 23.8 16.1 26.8 16.9 25.0 14.2
35 15.1 12.9 18.0 14.3 21.0 15.5 22.4 15.7 23.8 16.1 26.8 16.9 24.6 14.0
37 15.1 12.9 18.0 14.3 21.0 15.5 22.4 15.7 23.8 16.1 26.8 16.9 24.3 13.8
39 15.1 12.9 18.0 14.3 21.0 15.5 22.4 15.7 23.8 16.1 26.8 16.9 23.9 13.6
14.1
Indoor unit
Ceiling Concealed Duct
- High Static
4-19 4-19
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
6.2 Heating Capacity
Heating capacity
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 1.7 1.7 1.7 1.7 1.7 1.7
-18.8 -19.0 1.7 1.7 1.7 1.7 1.7 1.7
-16.7 -17.0 1.8 1.8 1.8 1.8 1.8 1.8
-14.7 -15.0 1.9 1.9 1.7 1.9 1.9 1.9
-12.6 -13.0 2.0 2.0 1.8 2.0 2.0 2.0
-10.5 -11.0 2.1 2.1 1.9 2.1 2.1 2.1
-9.5 -10.0 2.2 2.2 1.9 2.2 2.2 2.1
-8.5 -9.1 2.2 2.2 2.0 2.2 2.2 2.1
-7.0 -7.6 2.3 2.3 2.0 2.2 2.2 2.2
-5.0 -5.6 2.4 2.4 2.1 2.3 2.3 2.2
-3.0 -3.7 2.5 2.5 2.2 2.4 2.4 2.2
0.0 -0.7 2.6 2.6 2.3 2.4 2.4 2.2
3.0 2.2 2.8 2.7 2.4 2.4 2.4 2.2
5.0 4.1 2.8 2.7 2.5 2.4 2.4 2.2
7.0 6.0 2.9 2.7 2.5 2.4 2.4 2.2
9.0 7.9 2.9 2.7 2.5 2.4 2.4 2.2
11.0 9.8 2.9 2.7 2.5 2.4 2.4 2.2
13.0 11.8 2.9 2.7 2.5 2.4 2.4 2.2
15.0 13.7 2.9 2.7 2.5 2.4 2.4 2.2
-19.8 -20.0 2.1 2.1 2.1 2.1 2.1 2.1
-18.8 -19.0 2.2 2.2 2.2 2.2 2.2 2.2
-16.7 -17.0 2.3 2.3 2.3 2.3 2.3 2.3
-14.7 -15.0 2.5 2.4 2.2 2.4 2.4 2.4
-12.6 -13.0 2.6 2.6 2.3 2.6 2.6 2.6
-10.5 -11.0 2.7 2.7 2.4 2.7 2.7 2.7
-9.5 -10.0 2.8 2.8 2.5 2.8 2.8 2.7
-8.5 -9.1 2.8 2.8 2.5 2.8 2.8 2.7
-7.0 -7.6 2.9 2.9 2.6 2.8 2.8 2.8
-5.0 -5.6 3.0 3.0 2.7 3.0 3.0 2.8
-3.0 -3.7 3.2 3.2 2.8 3.1 3.0 2.8
0.0 -0.7 3.4 3.4 3.0 3.1 3.0 2.8
3.0 2.2 3.6 3.4 3.1 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.7 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.7 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.7 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.7 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.7 3.4 3.2 3.1 3.0 2.8
-19.8 -20.0 2.7 2.7 2.7 2.6 2.6 2.6
-18.8 -19.0 2.8 2.8 2.8 2.8 2.7 2.7
-16.7 -17.0 2.9 2.9 2.9 2.9 2.9 2.9
-14.7 -15.0 3.1 3.0 2.7 3.0 3.0 3.0
-12.6 -13.0 3.2 3.2 2.9 3.2 3.2 3.2
-10.5 -11.0 3.4 3.4 3.0 3.4 3.4 3.4
-9.5 -10.0 3.4 3.4 3.1 3.4 3.4 3.4
-8.5 -9.1 3.5 3.5 3.2 3.5 3.5 3.4
-7.0 -7.6 3.6 3.6 3.3 3.6 3.6 3.5
-5.0 -5.6 3.8 3.8 3.4 3.7 3.7 3.5
-3.0 -3.7 4.0 4.0 3.5 3.9 3.8 3.5
0.0 -0.7 4.2 4.2 3.7 3.9 3.8 3.5
3.0 2.2 4.4 4.3 3.9 3.9 3.8 3.5
5.0 4.1 4.5 4.3 4.0 3.9 3.8 3.5
7.0 6.0 4.6 4.3 4.0 3.9 3.8 3.5
9.0 7.9 4.6 4.3 4.0 3.9 3.8 3.5
11.0 9.8 4.6 4.3 4.0 3.9 3.8 3.5
13.0 11.8 4.6 4.3 4.0 3.9 3.8 3.5
15.0 13.7 4.6 4.3 4.0 3.9 3.8 3.5
2.2
2.8
3.6
Notes:
TC: Total Capacity(kW)
Indoor unit
Ceiling Concealed Duct
- High Static
4-20 4-20
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
Heating capacity
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 3.4 3.4 3.4 3.3 3.3 3.3
-18.8 -19.0 3.5 3.5 3.5 3.5 3.4 3.4
-16.7 -17.0 3.7 3.7 3.7 3.7 3.7 3.6
-14.7 -15.0 3.9 3.8 3.4 3.8 3.8 3.8
-12.6 -13.0 4.1 4.1 3.6 4.0 4.0 4.0
-10.5 -11.0 4.3 4.3 3.8 4.3 4.2 4.2
-9.5 -10.0 4.3 4.3 3.9 4.3 4.3 4.3
-8.5 -9.1 4.4 4.4 4.0 4.4 4.4 4.3
-7.0 -7.6 4.6 4.6 4.1 4.4 4.4 4.4
-5.0 -5.6 4.8 4.8 4.3 4.6 4.6 4.4
-3.0 -3.7 5.0 5.0 4.4 4.8 4.7 4.4
0.0 -0.7 5.3 5.3 4.6 4.8 4.7 4.4
3.0 2.2 5.6 5.4 4.9 4.8 4.7 4.4
5.0 4.1 5.6 5.4 5.0 4.8 4.7 4.4
7.0 6.0 5.8 5.4 5.0 4.8 4.7 4.4
9.0 7.9 5.8 5.4 5.0 4.8 4.7 4.4
11.0 9.8 5.8 5.4 5.0 4.8 4.7 4.4
13.0 11.8 5.8 5.4 5.0 4.8 4.7 4.4
15.0 13.7 5.8 5.4 5.0 4.8 4.7 4.4
-19.8 -20.0 4.2 4.2 4.2 4.2 4.2 4.2
-18.8 -19.0 4.3 4.3 4.3 4.3 4.3 4.3
-16.7 -17.0 4.6 4.6 4.6 4.6 4.6 4.5
-14.7 -15.0 4.9 4.8 4.3 4.8 4.8 4.8
-12.6 -13.0 5.1 5.1 4.5 5.0 5.0 5.0
-10.5 -11.0 5.4 5.4 4.8 5.4 5.3 5.3
-9.5 -10.0 5.4 5.4 4.9 5.4 5.4 5.4
-8.5 -9.1 5.5 5.5 5.0 5.5 5.5 5.4
-7.0 -7.6 5.7 5.7 5.1 5.6 5.6 5.5
-5.0 -5.6 6.0 6.0 5.4 5.8 5.8 5.5
-3.0 -3.7 6.2 6.2 5.5 6.1 5.9 5.5
0.0 -0.7 6.6 6.6 5.8 6.1 5.9 5.5
3.0 2.2 7.0 6.7 6.2 6.1 5.9 5.5
5.0 4.1 7.1 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.2 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.2 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.2 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.2 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.2 6.7 6.3 6.1 5.9 5.5
-19.8 -20.0 5.4 5.4 5.4 5.3 5.3 5.3
-18.8 -19.0 5.5 5.5 5.5 5.5 5.4 5.4
-16.7 -17.0 5.8 5.8 5.8 5.8 5.8 5.8
-14.7 -15.0 6.2 6.1 5.5 6.1 6.1 6.1
-12.6 -13.0 6.5 6.5 5.8 6.4 6.4 6.4
-10.5 -11.0 6.8 6.8 6.0 6.8 6.7 6.7
-9.5 -10.0 6.9 6.9 6.2 6.9 6.9 6.8
-8.5 -9.1 7.0 7.0 6.3 7.0 7.0 6.8
-7.0 -7.6 7.3 7.3 6.5 7.1 7.1 7.0
-5.0 -5.6 7.6 7.6 6.8 7.4 7.4 7.0
-3.0 -3.7 7.9 7.9 7.0 7.7 7.5 7.0
0.0 -0.7 8.4 8.4 7.4 7.8 7.5 7.0
3.0 2.2 8.9 8.6 7.8 7.8 7.5 7.0
5.0 4.1 9.0 8.6 8.0 7.8 7.5 7.0
7.0 6.0 9.2 8.6 8.0 7.8 7.5 7.0
9.0 7.9 9.2 8.6 8.0 7.8 7.5 7.0
11.0 9.8 9.2 8.6 8.0 7.8 7.5 7.0
13.0 11.8 9.2 8.6 8.0 7.8 7.5 7.0
15.0 13.7 9.2 8.6 8.0 7.8 7.5 7.0
4.5
5.6
7.1
Notes:
TC: Total Capacity(kW)
Indoor unit
Ceiling Concealed Duct
- High Static
4-21 4-21
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
Notes:
TC: Total Capacity(kW)
Heating capacity
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 6.2 6.2 6.2 6.1 6.1 6.1
-18.8 -19.0 6.3 6.3 6.3 6.3 6.3 6.3
-16.7 -17.0 6.7 6.7 6.7 6.7 6.7 6.6
-14.7 -15.0 7.1 7.0 6.3 7.0 7.0 7.0
-12.6 -13.0 7.5 7.5 6.6 7.4 7.4 7.4
-10.5 -11.0 7.8 7.8 7.0 7.8 7.7 7.7
-9.5 -10.0 7.9 7.9 7.1 7.9 7.9 7.8
-8.5 -9.1 8.1 8.1 7.3 8.1 8.1 7.9
-7.0 -7.6 8.4 8.4 7.5 8.2 8.2 8.0
-5.0 -5.6 8.7 8.7 7.8 8.5 8.5 8.0
-3.0 -3.7 9.1 9.1 8.1 8.9 8.6 8.0
0.0 -0.7 9.7 9.7 8.5 8.9 8.6 8.0
3.0 2.2 10.2 9.8 9.0 8.9 8.6 8.0
5.0 4.1 10.4 9.8 9.2 8.9 8.6 8.0
7.0 6.0 10.6 9.8 9.2 8.9 8.6 8.0
9.0 7.9 10.6 9.8 9.2 8.9 8.6 8.0
11.0 9.8 10.6 9.8 9.2 8.9 8.6 8.0
13.0 11.8 10.6 9.8 9.2 8.9 8.6 8.0
15.0 13.7 10.6 9.8 9.2 8.9 8.6 8.0
-19.8 -20.0 8.0 8.0 8.0 7.9 7.9 7.9
-18.8 -19.0 8.2 8.2 8.2 8.2 8.1 8.1
-16.7 -17.0 8.7 8.7 8.7 8.7 8.7 8.6
-14.7 -15.0 9.2 9.0 8.2 9.0 9.0 9.1
-12.6 -13.0 9.6 9.6 8.6 9.5 9.5 9.5
-10.5 -11.0 10.1 10.1 9.0 10.1 10.0 10.0
-9.5 -10.0 10.2 10.2 9.2 10.2 10.2 10.1
-8.5 -9.1 10.5 10.5 9.4 10.5 10.5 10.2
-7.0 -7.6 10.8 10.8 9.7 10.6 10.6 10.4
-5.0 -5.6 11.3 11.3 10.1 11.0 11.0 10.4
-3.0 -3.7 11.8 11.8 10.4 11.5 11.2 10.4
0.0 -0.7 12.5 12.5 11.0 11.5 11.2 10.4
3.0 2.2 13.2 12.7 11.6 11.5 11.2 10.4
5.0 4.1 13.4 12.7 11.9 11.5 11.2 10.4
7.0 6.0 13.7 12.7 11.9 11.5 11.2 10.4
9.0 7.9 13.7 12.7 11.9 11.5 11.2 10.4
11.0 9.8 13.7 12.7 11.9 11.5 11.2 10.4
13.0 11.8 13.7 12.7 11.9 11.5 11.2 10.4
15.0 13.7 13.7 12.7 11.9 11.5 11.2 10.4
-19.8 -20.0 9.2 9.2 9.2 9.1 9.1 9.1
-18.8 -19.0 9.5 9.5 9.5 9.5 9.4 9.4
-16.7 -17.0 10.1 10.1 10.1 10.1 10.1 9.9
-14.7 -15.0 10.6 10.5 9.5 10.5 10.5 10.5
-12.6 -13.0 11.2 11.2 10.0 11.0 11.0 11.0
-10.5 -11.0 11.7 11.7 10.4 11.7 11.6 11.6
-9.5 -10.0 11.9 11.9 10.7 11.9 11.9 11.7
-8.5 -9.1 12.1 12.1 10.9 12.1 12.1 11.8
-7.0 -7.6 12.6 12.6 11.3 12.2 12.2 12.1
-5.0 -5.6 13.1 13.1 11.7 12.8 12.8 12.1
-3.0 -3.7 13.7 13.7 12.1 13.3 13.0 12.1
0.0 -0.7 14.5 14.5 12.8 13.4 13.0 12.1
3.0 2.2 15.3 14.8 13.5 13.4 13.0 12.1
5.0 4.1 15.5 14.8 13.8 13.4 13.0 12.1
7.0 6.0 15.9 14.8 13.8 13.4 13.0 12.1
9.0 7.9 15.9 14.8 13.8 13.4 13.0 12.1
11.0 9.8 15.9 14.8 13.8 13.4 13.0 12.1
13.0 11.8 15.9 14.8 13.8 13.4 13.0 12.1
15.0 13.7 15.9 14.8 13.8 13.4 13.0 12.1
8.2
10.6
12.3
Indoor unit
Ceiling Concealed Duct
- High Static
4-22 4-22
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
Heating capacity
Notes:
TC: Total Capacity(kW)
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 10.7 10.7 10.7 10.5 10.5 10.5
-18.8 -19.0 11.0 11.0 11.0 11.0 10.8 10.8
-16.7 -17.0 11.6 11.6 11.6 11.6 11.6 11.4
-14.7 -15.0 12.2 12.1 10.9 12.1 12.1 12.1
-12.6 -13.0 12.9 12.9 11.5 12.7 12.7 12.7
-10.5 -11.0 13.5 13.5 12.0 13.5 13.4 13.4
-9.5 -10.0 13.7 13.7 12.3 13.7 13.7 13.5
-8.5 -9.1 14.0 14.0 12.6 14.0 14.0 13.6
-7.0 -7.6 14.5 14.5 13.0 14.1 14.1 13.9
-5.0 -5.6 15.1 15.1 13.5 14.7 14.7 13.9
-3.0 -3.7 15.7 15.7 13.9 15.3 14.9 13.9
0.0 -0.7 16.7 16.7 14.7 15.4 14.9 13.9
3.0 2.2 17.7 17.0 15.5 15.4 14.9 13.9
5.0 4.1 17.9 17.0 15.9 15.4 14.9 13.9
7.0 6.0 18.3 17.0 15.9 15.4 14.9 13.9
9.0 7.9 18.3 17.0 15.9 15.4 14.9 13.9
11.0 9.8 18.3 17.0 15.9 15.4 14.9 13.9
13.0 11.8 18.3 17.0 15.9 15.4 14.9 13.9
15.0 13.7 18.3 17.0 15.9 15.4 14.9 13.9
-19.8 -20.0 16.9 16.9 16.9 16.6 16.6 16.6
-18.8 -19.0 17.4 17.4 17.4 17.4 17.1 17.1
-16.7 -17.0 18.4 18.4 18.4 18.4 18.4 18.1
-14.7 -15.0 19.4 19.2 17.3 19.2 19.2 19.2
-12.6 -13.0 20.4 20.4 18.2 20.2 20.2 20.2
-10.5 -11.0 21.4 21.4 19.1 21.4 21.2 21.2
-9.5 -10.0 21.7 21.7 19.5 21.7 21.7 21.4
-8.5 -9.1 22.2 22.2 19.9 22.2 22.2 21.6
-7.0 -7.6 22.9 22.9 20.6 22.4 22.4 22.0
-5.0 -5.6 23.9 23.9 21.5 23.3 23.3 22.0
-3.0 -3.7 25.0 25.0 22.1 24.3 23.7 22.0
0.0 -0.7 26.5 26.5 23.4 24.4 23.7 22.0
3.0 2.2 28.0 27.0 24.6 24.4 23.7 22.0
5.0 4.1 28.4 27.0 25.2 24.4 23.7 22.0
7.0 6.0 29.0 27.0 25.2 24.4 23.7 22.0
9.0 7.9 29.0 27.0 25.2 24.4 23.7 22.0
11.0 9.8 29.0 27.0 25.2 24.4 23.7 22.0
13.0 11.8 29.0 27.0 25.2 24.4 23.7 22.0
15.0 13.7 29.0 27.0 25.2 24.4 23.7 22.0
-19.8 -20.0 21.1 21.1 21.1 20.8 20.8 20.8
-18.8 -19.0 21.7 21.7 21.7 21.7 21.4 21.4
-16.7 -17.0 23.0 23.0 23.0 23.0 23.0 22.7
-14.7 -15.0 24.3 23.9 21.6 23.9 23.9 24.0
-12.6 -13.0 25.5 25.5 22.7 25.2 25.2 25.2
-10.5 -11.0 26.8 26.8 23.8 26.8 26.5 26.5
-9.5 -10.0 27.1 27.1 24.4 27.1 27.1 26.8
-8.5 -9.1 27.7 27.7 24.9 27.7 27.7 27.0
-7.0 -7.6 28.7 28.7 25.7 28.0 28.0 27.6
-5.0 -5.6 29.9 29.9 26.8 29.1 29.1 27.6
-3.0 -3.7 31.2 31.2 27.6 30.3 29.6 27.6
0.0 -0.7 33.1 33.1 29.2 30.5 29.6 27.6
3.0 2.2 35.0 33.7 30.8 30.5 29.6 27.6
5.0 4.1 35.4 33.7 31.5 30.5 29.6 27.6
7.0 6.0 36.2 33.7 31.5 30.5 29.6 27.6
9.0 7.9 36.2 33.7 31.5 30.5 29.6 27.6
11.0 9.8 36.2 33.7 31.5 30.5 29.6 27.6
13.0 11.8 36.2 33.7 31.5 30.5 29.6 27.6
15.0 13.7 36.2 33.7 31.5 30.5 29.6 27.6
14.1
22.4
28.0
Indoor unit
Ceiling Concealed Duct
- High Static
4-23 4-23
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
7. External Static Pressure (E.S.P) & Air Flow
Note: 1. The above table shows the correlation between the air rates and E.S.P.
ARNU07GBHA2, ARNU09GBHA2, ARNU12GBHA2
ARNU15GBHA2, ARNU18GBHA2, ARNU24GBHA2
Setting Value
70 - - - - - - - - -
80 4.0 - - - - - - - -
90 12.1 6.9 4.13 - - - - - -
100 17.0 15.5 11.01 6.2 4.2 - - - -
110 21.4 19.6 17.53 14.0 11.6 6.6 - - -
120 25.8 24.0 21.8 19.8 17.9 14.6 12.1 - -
130 30.0 28.5 26.93 25.3 23.4 21.8 18.1 14.6 11.3
140 36.0 32.1 30.41 29.0 27.4 25.9 21.6 17.8 14.5
143 37.5 33.9 32.1 30.7 28.8 27.2 23.0 20.1 16.8
150 41.0 38.0 36.0 34.5 32.1 30.1 26.3 22.4 18.2
160 42.4 41.6 38.2 36.1 35 34.6 31.1 26.8 23.3
5(49) 6(59) 7(69) 8(78) 9(88) 10(98) 12(118) 14(137) 16(157)
Static Pressure(mmAq(Pa))
ARNU28GBGA2, ARNU36GBGA2, ARNU42GBGA2
Setting Value
91 46.5 43.7 38.2 31.3 23.2 14.0 9.0 3.7 - - -
96 49.9 46.1 43.0 33.5 31.1 18.4 13.7 9.0 2.6 - -
101 52.1 50.2 47.9 39.5 37.4 27.3 25.2 17.8 8.9 6.1 -
106 51.4 51.2 50.4 44.4 43.1 33.3 32.1 28.9 21.0 17.9 8.3
111 53.6 53.7 52.9 49.9 48.3 40.6 40.2 32.8 31.5 27.2 17.5
116 62.3 61.0 60.3 55.7 50.8 44.8 42.6 40.1 37.6 32.5 27.6
121 67.0 64.8 64.1 58.2 52.2 50.8 50.3 45.7 44.6 38.8 32.2
126 68.2 67.5 66.2 65.1 64.3 57.4 54.4 51.2 50.4 46.0 43.5
5(49) 6(59) 8(78) 10(98) 12(118) 14(137) 15(147) 16(157) 17(168) 18(176) 20(196)
Static Pressure(mmAq(Pa))
ARNU48GBRA2
(Unit: CMM)
(Unit: CMM)
(Unit: CMM)
Setting Value
70 4.1 - - - - - - - -
80 7.6 - - - - - - - -
90 10.7 8.1 6.3 4.9 - - - - -
100 13.4 11.2 9.6 7.5 4.0 - - - -
110 15.9 13.2 12.6 10.3 7.7 5.5 - - -
120 18.6 16.2 15.2 12.8 11.1 9.1 6.7 5.3 -
130 19.8 18.8 18.0 15.3 14.2 12.4 10.4 8.8 5.7
140 22.3 21.1 20.3 17.7 17.1 15.5 13.7 12.6 9.7
145 23.2 22.2 21.4 19.1 18.4 16.9 15.3 13.8 11.8
150 24.3 23.1 22.3 21.1 19.8 18.3 16.8 15.2 13.0
3(29) 4(39) 5(49) 6(59) 7(69) 8(78) 9(88) 10(98) 12(118)
Static Pressure(mmAq(Pa))
Indoor unit
Ceiling Concealed Duct
- High Static
4-24 4-24
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
Note: 1. The above table shows the correlation between the air rates and E.S.P.
URNU76GB8A2, URNU96GB8A2
(Unit: CMM)
Setting Value
60 40.5 - - - - - - - -
65 52.7 - - - - - - - -
70 63.7 47.1 - - - - - - -
75 71.1 56.9 44.7 - - - - - -
80 76.3 69.7 55.2 - - - - - -
85 83.3 78.6 67.4 55.9 - - - - -
91 89.7 87.1 78.9 67.6 54.2 - - - -
95 93.4 91.4 86.1 77.0 66.4 50.6 30.0 - -
100 93.4 91.4 88.3 84.9 75.9 69.5 60.8 43.1 -
105 93.2 91.3 88.3 84.9 81.1 77.4 69.2 67.9 51.3
6(59) 9(88) 12(118) 15(147) 18(177) 20(196) 22(216) 23(226) 25(245)
Static Pressure(mmAq(Pa))
Indoor unit
Ceiling Concealed Duct
- High Static
4-25 4-25
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
ARNU07GBHA2, ARNU09GBHA2, ARNU12GBHA2
ARNU15GBHA2, ARNU18GBHA2, ARNU24GBHA2
ARNU28GBGA2, ARNU36GBGA2, ARNU42GBGA2
Capacity Mode Set value
18k
High
(factory set)
High
(factory set)
HI 140
Mid 135
Low 130
HI 130
Mid 125
Low 110
HI 150
Mid 145
Low 140
HI 145
Mid 135
Low 128
15.5
13.5
12.4
15.3
13.6
10.3
18.3
16.9
15.5
19
16.4
14.5
8(78)
6(59)
8(78)
6(59)
6(59) 12(118)
4(39) 8(78)
6(59) 12(118)
4(39) 8(78)
Standard
Standard
24k
Standard
ESP(mmAq(Pa))
CMM
Lower Limit of External
Static Pressure(mmAq(Pa))
Upper Limit of External
Static Pressure(mmAq(Pa))
Capacity Mode Set value
28k
High
(factory set)
High
(factory set)
High
(factory set)
HI 140
Mid 136
Low 130
HI 130
Mid 124
Low 116
HI 151
Mid 145
Low 139
HI 138
Mid 130
Low 124
HI 157
Mid 154
Low 151
HI 145
Mid 138
Low 134
25.9
24.1
21.8
25.3
21.8
17.6
32.3
29
25.3
28.4
25.3
21.8
34.5
32.3
30.7
32
28.4
27.2
10(98)
8(78)
10(98)
8(78)
10(98)
8(78)
8(78) 16(157)
6(59) 10(98)
8(78) 14(137)
6(59) 10(98)
8(78) 12(118)
6(59) 10(98)
Standard
Standard
Standard
36k
42k
Standard
ESP(mmAq(Pa))
CMM
Lower Limit of External
Static Pressure(mmAq(Pa))
Upper Limit of External
Static Pressure(mmAq(Pa))
7k
High
(factory set)
High
(factory set)
Standard
High
(factory set)
Hl 120
Mid 117
Low 115
Hl 110
Mid 107
Low 105
Hl 125
Mid 120
Low 117
Hl 110
Mid 107
Low 105
Hl 130
Mid 125
Low 120
Hl 115
Mid 110
Low 105
Hl 135
Mid 130
Low 120
Hl 123
Mid 120
Low 115
8.5
7.5
6
8.5
8
7.5
10
8.5
7.5
8.5
8
7.5
12
10
8.5
11
8.5
7.5
13.5
12
8.5
13.5
12
11
8(78)
6(59)
8(78)
6(59)
8(78)
6(59)
8(78)
6(59)
6(59) 12(118)
4(39) 8(78)
6(59) 12(118)
4(39) 8(78)
6(59) 12(118)
4(39) 8(78)
6(59) 12(118)
4(39) 8(78)
Standard
Standard
9k
12k
High
(factory set)
Standard
15k
Indoor unit
Ceiling Concealed Duct
- High Static
4-26 4-26
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
URNU76GB8A2, URNU96GB8A2
ARNU48GBRA2
Capacity Mode Set value
48k
High
(factory set)
HI 116
Mid 111
Low 106
HI 106
Mid 101
Low 96
44.8
40.6
33.3
44.4
39.5
33.5
14(137)
10(98)
10(98) 20(196)
7(67) 14(137) Standard
Standard
ESP(mmAq(Pa))
CMM
Lower Limit of External
Static Pressure(mmAq(Pa))
Upper Limit of External
Static Pressure(mmAq(Pa))
Capacity Mode Set value
76k
High
(factory set)
High
(factory set)
HI 102
Mid 98
Low 98
HI 86
Mid 83
Low 83
HI 105
Mid 102
Low 102
HI 94
Mid 89
Low 89
60
50
50
64
50
50
72
64
64
76
64
64
22(216)
15(147)
22(216)
15(147)
12(118) 25(245)
12(118) 25(245)
12(118) 25(245)
12(118) 25(245)
Standard
Standard
96k
Standard
ESP(mmAq(Pa))
CMM
Lower Limit of External
Static Pressure(mmAq(Pa))
Upper Limit of External
Static Pressure(mmAq(Pa))
Indoor unit
Ceiling Concealed Duct
- High Static
4-27 4-27
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
Units
Model Type Hz Volts Voltage Range
ARNU07GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU09GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU12GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU15GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU18GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU24GBHA2 BH
50 220-240
Max:264 1.32 15 0.118 1.06 150 150
ARNU28GBGA2 BG Min:198 3.31 15 0.39 2.65 450 450
ARNU36GBGA2 BG 3.31 15 0.39 2.65 450 450
ARNU42GBGA2 BG 3.31 15 0.39 2.65 450 450
ARNU48GBRA2 BR 3.45 15 0.39 2.76 450 450
URNU76GB8A2 B8 6.47 15 0.75 5.18 800 800
URNU96GB8A2 B8 6.47 15 0.75 5.18 800 800
ARNU07GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU09GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU12GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU15GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU18GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU24GBHA2 BH
60 220
Max:242 1.32 15 0.118 1.06 150 150
ARNU28GBGA2 BG Min:198 3.31 15 0.39 2.65 450 450
ARNU36GBGA2 BG 3.31 15 0.39 2.65 450 450
ARNU42GBGA2 BG 3.31 15 0.39 2.65 450 450
ARNU48GBRA2 BR 3.45 15 0.39 2.76 450 450
URNU76GB8A2 B8 6.47 15 0.75 5.18 800 800
URNU96GB8A2 B8 6.47 15 0.75 5.18 800 800
Power Supply IFM Input(W)
MCA MFA kW FLA Cooling Heating
8. Electric Characteristics
Symbols:
MCA : Min, Circuit Amps(A)
MFA : Max. Fuse Amps(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amps(A)
IFM : Indoor Fan Motor
Note :
1. Voltage range
Units are suitable for use on electrical systems where voltage sup-
plied to unit terminals is not below or above the listed range limits,
2. Maximum allowable voltage unbalance between phases is 2%
3. MCA/MFA
MCA=1.25 x FLA
MFA 4 x FLA
(Next lower standard fuse rating. Min. 15A)
4. Select wire size based on the MCA
5. Instead of fuse, use Circuit Breaker.
Indoor unit
Ceiling Concealed Duct
- High Static
4-28 4-28
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
9. Sound Levels
Overall
Sound Pressure Level
Notes:
- Sound measured at 1.5m away from the center of the unit.
- Data is valid at free field condition
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.
1.5m
1m
2m 1m
DUCT
DISCHARGE SUCTION
DUCT
Model
Sound Level dB(A)
H M L
34
35
37
39
42.5
45
33
34
35
38
41
43
32
33
34
37
37
41
ARNU07GBHA2
ARNU09GBHA2
ARNU12GBHA2
ARNU15GBHA2
ARNU18GBHA2
ARNU24GBHA2
Model
Sound Level dB(A)
H M L
44
46
48
45
50
52
42
44
46
43
48
50
40
42
45
41
48
50
ARNU28GBGA2
ARNU36GBGA2
ARNU42GBGA2
ARNU48GBRA2
URNU76GB8A2
URNU96GB8A2
ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
Indoor unit
Ceiling Concealed Duct
- High Static
4-29 4-29
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
ARNU36GBGA2 ARNU42GBGA2
ARNU48GBRA2 URNU76GB8A2 URNU96GB8A2
ARNU15GBHA2 ARNU18GBHA2 ARNU24GBHA2
ARNU28GBGA2
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
Indoor unit
Ceiling Concealed Duct
- High Static
4-30 4-30
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
10. Installation
Please read this instruction sheet completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
Air filters
Air intake vents
Air outlet vents
Remote Controller
TEMP
Wired LCD Remote Control
Required Parts Required Tools
Connecting cable
Pipes: Gas side
Liquid side
Hanging Bolt
(W 3/8 or M10 length 650mm)
Insulated drain hose
Additional Drain hose
Level
Screw driver
Electric drill
Hole core drill
Flaring Tool set
Torque Wrenches
Hexagonal Wrench
Gas-leak detector
Thermometer
10.1 Selection of the best location
Install the air conditioner in the location that satisfies the
following conditions.
The place shall easily bear a load exceeding four times
the indoor units weight.
The place shall be able to inspect the unit as the figure.
The place where the unit shall be leveled.
The place shall allow easy water drainage.(Suitable
dimension H is necessary to get a slope to drain as fig-
ure.)
The place shall easily connect with the outdoor unit.
The place where the unit is not affected by an electrical
noise.
The place where air circulation in the room will be good .
There should not be any heat source or steam near the
unit.
The servicing inspection hole in the ceiling should be as
large as the product
The selection of the servicing hole should be approved
by the customer
Minimum height for
motor replacement.
Less than 20cm
Hole size should be
more than the size of IDU.
Insufficient space.
Difficult for servicing
20cm to 100cm 2
Sufficient space in the
ceiling for servicing.
More than 100cm 1
Remarks
Distance between
False ceiling & Actual ceiling
Number of
Inspection hole
[Inspection Hole Standard]
Indoor unit
Ceiling Concealed Duct
- High Static
4-31 4-31
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
10.2 Ceiling dimension and hang-
ing bolt location
I Installation of Unit
Install the unit above the ceiling correctly.
Apply a joint-canvas between the unit and duct to absorb
unnecessary vibration.
Apply a filter Accessory at air return hole.
Refer to the Dimensions.
Install the unit leaning to a drainage hole side as a figure
for easy water drainage.
A place where the unit will be leveled and that can sup-
port the weight of the unit.
A place where the unit can withstand its vibration.
A place where service can be easily performed.
CASE 1
POSITION OF SUSPENSION BOLT
CASE 2
POSITION OF CONSOLE BOLT
Drainage hole
M10 Nut
M10 washer
X 4
X 4
M10 Nut
M10 washer X 4
X 8
A
B
C
D
(G)
H
I
E
F
B8 Chassis
BH/BG/BR Chassis
(Unit:mm)
A B C D E F G H I J K L
B8 1680 1565 1160 330 460 580 700 1400 1635 390 445 15
Dimension
Chassis
(Unit:mm)
A B C D E F (G) H I
BH 932 882 355 47 450 30 87 750 158
BG 1232 1182 355 47 450 30 87 830 186
BR 1282 1230 477 56 590 30 120 1006 294
Dimension
Chassis
Indoor unit
Ceiling Concealed Duct
- High Static
4-32 4-32
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
Select and mark the position for fixing bolts.
Drill the hole for set anchor on the face of ceiling.
Insert the set anchor and washer onto the suspen-
sion bolts for locking the suspension bolts on the
ceiling.
Mount the suspension bolts to the set anchor firmly.
Secure the installation plates onto the suspension
bolts (adjust level roughly) using nuts, washers and
spring washers.
Tighten the nut and bolt to prevent unit falling.
CAUTION
1 Set anchor
Old building New building
2 Plate washer
3 Spring washer
4 Nut
5 Suspension
bolts
10.3 Connecting Cables between Indoor Unit and Outdoor Unit
Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively
Clamping of cables
1) Arrange 2 power cables on the control panel.
2) First, fasten the steel clamp with a screw to the inner boss of control panel.
3) For the cooling model, fix the other side of the clamp with a screw strongly. For the heat pump model, put the
0.75mm
2
cable(thinner cable) on the clamp and tighten it with a plastic clamp to the other boss of the control panel.
Make sure that the screws of the terminal are not loose.
WARNING
Terminal Block Indoor
1(L) 2(N) 3 4
INDOOR POWER INPUT
A - - - - - - B A B
GND 12V DRY2 DRY1 INTERNET IDU SODU Outdoor
Unit
NOTE:
Throughly study the following installation locations:
1. In such places as restaurants and kitchens, considerable amount of oil steam and flour adhere to the fan, the fin of the heat
exchanger, resulting in heat exchange reduction, spraying, dispersing of water drops, etc.
In these cases, take the following actions:
Make sure that the ventilation fan for smoke-collecting hood on a cooking table has sufficient capacity so that it draws oily
steam which should not flow into the suction of the air conditioner.
Make enough distance from a cooking room to install the air conditioner in such a place where it may not suck in oil steam.
2. Avoid installing air conditioner in such circumstances where cutting oil mist or iron powder is in suspension in factories, etc.
3. Avoid places where inflammable gas is generated, flows in, is stored or vented.
4. Avoid places where sulfurous acid gas or corrosive gas is generated.
5. Avoid places near high frequency generators.
Indoor unit
Ceiling Concealed Duct
- High Static
4-33 4-33
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
All thermal insulation must comply with local requirement.
INDOOR UNIT
THERMAL INSULATION
Make sure that there is no clearance here.
Overlap with thermal
insulator for piping.
Thermal insulator for refrigerant pipe
(Local supply)
Thermal insulator for
piping(Local supply)
Hose clamp for thermal insulator(Local supply)
Union for liquid pipe
Refrigerant pipe and thermal
insulator(Local supply)
Union for gas pipe
Thermal insulator for refrigerant pipe
(Local supply)
Hose clamp for thermal insulator
(Local supply)
Union for liquid pipe
Refrigerant pipe and therma
insulator(Local supply)
Union for gas pipe
Thermal insulator for refrigerant pipe
(Local supply)
Hose crip for thermal insulator
(Local supply)
B8
BH/BG/BR Chassis
10.4 Checking the Drainage
1) Checking the Drainage
1. Remove the Air Filter.
2. Check the drainage.
Spray one or two glasses of water on the evapo-
rator.
Ensure that water flows through drain hose of
indoor unit without any leakage.
B8
BH/BG/BR Chassis
Indoor unit
Ceiling Concealed Duct
- High Static
4-34 4-34
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
10.5 Indoor Unit Drain Piping
Drain piping must have down-slope (1/50 to 1/100): be sure not to pro-
vide up-and-down slope to prevent reversal flow.
During drain piping connection, be careful not to exert extra force on the
drain port on the indoor unit.
The outside diameter of the drain connection on the indoor unit is 32mm.
Be sure to install heat insulation on the drain piping.
Piping material: Polyvinyl chloride pipe inner
diometes 25mm and pipe fittings
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:
Connect the main drain pipe to the exterior and leave it pro-
visionally until the test comes to an end.
Feed water to the flexible drain hose and check the piping
for leakage.
Be sure to check the drain pump for normal operation and
noise when electrical wiring is complete.
When the test is complete, connect the flexible drain hose to
the drain port on the indoor unit.
Heat insulation material: Polyethylene foam with
thickness more than 8 mm.
Drain test
Maintenance
drain port
Upward
routing
not allowed
Pipe clamp
Indoor unit
1/50~1/100
MAX 700mm
Feed water
Drain Pump
Drain pan
Flexible drain hose
(accessory)
Main
drain pipe
Glue the joint
Drain
port
Drain hose connection
Use the clip (accessory)
CAUTION
The supplied flexible drain hose should not be strained.
A strained hose may cause leakage of water.
1/50~1/100 slope
Hanger
distance
Hanger Bracket
M
a
x

7
0
0
m
m
Flexible drain hose
Insulation
Metal
clamp
Max 300mm
1~15m
Indoor unit
Ceiling Concealed Duct
- High Static
4-35 4-35
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
10.6 Ground drain piping
a) It is standard work practice to make connections to the main pipe from above. The pipe down from the
combination should be as large as possible.
10.7 Use of an auxiliary drain hose(flexible)
a) To connect drain pipe to the drain socket on the indoor unit, an auxiliary flexible drain hose should be
used. auxiliary flexible drain hose allows that the drain pipe can be connected to the socket without break-
ing by excessive strain.
Important points
- The drain pipe should be at least equal in size to that of the indoor unit.
- The drain pipe is thermally insulated to prevent the formation of condensation inside the pipe.
- The drain up mechanism should be fitted before the indoor unit is installed and when the electricity has
been connected some water should be added to the drain pan and the drain pump to check and see if it is
functioning correctly.
- All connections should be secure. (Special care is needed with PVC pipe)
- Insulate auxiliary drain hose with thermal insulation band.
b) The pipe work should be kept as short as possible and the number of indoor units per group kept to a
minimum.
Face piping
downward
Vent pipe
Face the vent pipe opening facing downward to
keep foreign matter from penetrating the system
Metal clamp
Drain pan
Metal clamp
Thermal insulation(bend area)
Auxiliary drain hose
Thermal insulation (drain pipe area)
Indoor unit
Ceiling Concealed Duct
- High Static
4-36 4-36
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
WIRED REMOTE CONTROLLER INSTALLATION
Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average tempera-
ture.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
Fig.1 Typical locations for remote controller
5feet
(1.5meters)
no
no
no
yes
Remote Controller
TEMP
Remote Controller
TEMP
Remote Controller
TEMP
Indoor unit
Ceiling Concealed Duct
- High Static
4-37 4-37
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

H
i
g
h

S
t
a
t
i
c
11. Accessories
Name
Quantity
Shape
for gas pipe
for liquid pipe
Clamp metal
1 EA
Insulation for
fitting
1 SET
Drain hose
1 EA
Clamp
(Tie Wrap)
8 EA
Washer for
hanging backet
4 EA
(Other)
Standard Accessories
Owner's manual
Installation manual
Use only those accessories (Standard or optional) which have designated specifications.
CAUTION
Indoor unit
Ceiling Concealed Duct
- Low Static
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
1. List of functions
2. Specifications
3. Dimensions & Gravity point
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. External Static Pressure (E.S.P) & Air Flow
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories
Ceiling Concealed Duct
(Low Static)
Indoor unit
Ceiling Concealed Duct
- Low Static
5-1 5-1
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
1. List of functions
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Air flow
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Air purifying Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
Installation
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Reliability Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Convenience Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Individual Simple wired remote controller
control Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Special
Zone control
function kit
CTIE
Electro thermostat
1
-
-
-
-
3 / 3 / 3
-
-
-
-
X
X
O
O
O
X
-
O
O
O
O(Heat recovery)
X
O(Heat pump or Cooling only)
O
O
-
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
X
Accessory
Accessory
-
-
Function Category
ARNU07GB1G2, ARNU09GB1G2, ARNU12GB1G2,
ARNU15GB1G2, ARNU18GB2G2, ARNU24GB2G2
O : Applied X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.
Indoor unit
Ceiling Concealed Duct
- Low Static
5-2 5-2
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
2. Specifications
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Noise Level is Standard Mode
(for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dB(A))
7. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Air Flow Rate(H / M / L) CMM
(High Mode-factory set) cfm
Fan External Static Pressure mmAq(Pa)
Air Flow Rate(H / M / L) CMM
(Standard Mode) cfm
External Static Pressure mmAq(Pa)
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Ceiling Concealed Duct (Low Static)
ARNU07GB1G2 ARNU09GB1G2 ARNU12GB1G2
2.2 2.8 3.6
1,900 2,400 3,100
7,500 9,600 12,300
2.5 3.2 4.0
2,200 2,800 3,400
8,500 10,900 13,600
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
820 x 575 x 190 820 x 575 x 190 820 x 575 x 190
32.3 x 21.7 x 7.5 32.3 x 21.7 x 7.5 32.3 x 21.7 x 7.5
2 x 11 x 21 2 x 11 x 21 2 x 11 x 21
0.16 0.16 0.16
Sirocco Fan Sirocco Fan Sirocco Fan
28 28 28
0.15 0.15 0.15
8.5 / 7.5 / 6.5 9.5 / 8.5 / 7.5 10.5 / 9.5 / 8.5
300 / 265 / 229 335 / 300 / 265 371 / 335 / 300
2(20) 2(20) 2(20)
8.5 / 7.5 / 6.5 9.5 / 8.5 / 7.5 10.5 / 9.5 / 8.5
300 / 265 / 229 335 / 300 / 265 371 / 335 / 300
0(0) 0(0) 0(0)
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene
- - -
Fuse Fuse Fuser
6.35(1/4) 6.35(1/4) 6.35(1/4)
12.7(1/2) 12.7(1/2) 12.7(1/2)
25.4(1) 25.4(1) 25.4(1)
21(46.3) 21(46.3) 21(46.3)
33 / 32 / 29 34 / 33 / 32 35 / 34 / 33
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Indoor unit
Ceiling Concealed Duct
- Low Static
5-3 5-3
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Noise Level is Standard Mode
(for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dB(A))
7. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Air Flow Rate(H / M / L) CMM
(High Mode-factory set) cfm
Fan External Static Pressure mmAq(Pa)
Air Flow Rate(H / M / L) CMM
(Standard Mode) cfm
External Static Pressure mmAq(Pa)
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Ceiling Concealed Duct (Low Static)
ARNU15GB1G2 ARNU18GB2G2 ARNU24GB2G2
4.5 5.6 7.1
3,900 4,800 6,100
15,400 19,100 24,200
5.0 6.3 8.0
4,300 5,400 6,900
17,100 21,500 27,300
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
820 x 575 x 190 1,100 x 575 x 190 1,100 x 575 x 190
32.3 x 21.7 x 7.5 43.3 x 21.7 x 7.5 43.3 x 21.7 x 7.5
2 x 11 x 21 3 x 10 x 18 3 x 10 x 18
0.16 0.23 0.23
Sirocco Fan Sirocco Fan Sirocco Fan
28 76 76
0.15 0.38 0.38
11.5 / 10.5 / 9.5 16.0 / 14.0 / 12.0 19.0 / 17.0 / 15.0
406 / 371 / 335 565 / 494 / 424 671 / 600 / 530
2(20) 2(20) 2(20)
11.5 / 10.5 / 9.5 16.0 / 14.0 / 12.0 19.0 / 17.0 / 15.0
406 / 371 / 335 565 / 494 / 424 671 / 600 / 530
0(0) 0(0) 0(0)
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene
- - -
Fuse Fuse Fuse
6.35(1/4) 6.35(1/4) 9.52(3/8)
12.7(1/2) 12.7(1/2) 15.88(5/8)
25.4(1) 25.4(1) 25.4(1)
21(46.3) 26(57.3) 26(57.3)
38 / 37 / 36 40 / 37 / 34 43 / 40 / 37
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Indoor unit
Ceiling Concealed Duct
- Low Static
5-4 5-4
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
3. Dimensions & Gravity point
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

B
1
/
B
2
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t

(
L
o
w

S
t
a
t
i
c
)
A
R
N
U
0
7
G
B
1
G
2

A
R
N
U
0
9
G
B
1
G
2
A
R
N
U
1
2
G
B
1
G
2
A
R
N
U
1
5
G
B
1
G
2
A
R
N
U
1
8
G
B
2
G
2
A
R
N
U
2
4
G
B
2
G
2
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
A
3 8 3
5 7 5
1 6 11 4
1 5 4
1 9 0
1 8
1
8
B
C
1
3
D
8
2
0
A
B
C
D
A
R
N
U
0
7
G
B
1
G
2

A
R
N
U
0
9
G
B
1
G
2
A
R
N
U
1
2
G
B
1
G
2
A
R
N
U
1
5
G
B
1
G
2
A
R
N
U
1
8
G
B
2
G
2
A
R
N
U
2
4
G
B
2
G
2
7
2
8
8
5
6
7
9
4
1
1
0
0
1
0
0
8
1
1
3
1
1
0
7
2
(
u
n
i
t
:

m
m
)
1
9
0
6
5
6
0
2 7 7
2 1 6
2 4
N
a
m
e
1
L
i
q
u
i
d

p
i
p
e

c
o
n
n
e
c
t
i
o
n
2
G
a
s

p
i
p
e

c
o
n
n
e
c
t
i
o
n

3
D
r
a
i
n

p
i
p
e

c
o
n
n
e
c
t
i
o
n

4
P
o
w
e
r

s
u
p
p
l
y

c
o
n
n
e
c
t
i
o
n

5
A
i
r

d
i
s
c
h
a
r
g
e

6
A
i
r

s
u
c
t
i
o
n
N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
(
u
n
i
t

:

m
m
)
U
n
i
t

s
i
z
e
(
7
k
,
9
k
,
1
2
k
,
1
8
k
)
:

6
.
3
5
U
n
i
t

s
i
z
e
(
2
4
k
)
:

9
.
5
2
U
n
i
t

s
i
z
e
(
7
k
,
9
k
,
1
2
k
,
1
8
k
)
:

1
2
.
7
U
n
i
t

s
i
z
e
(
2
4
k
)
:

1
5
.
8
8
5
6
2
1
3
4
G
r
a
v
i
t
y

p
o
i
n
t
B 1 : 1 8 6
B 2 : 1 7 5
B
1

:

4
4
8
B
2

:

5
7
3
B 1 : 7 3
B 2 : 8 1
Indoor unit
Ceiling Concealed Duct
- Low Static
5-5 5-5
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
4. Piping Diagrams
Heat Exchanger
Sirocco Fan
Th3
Th1
Th2
lndoor unit
EEV
:Heating
:Cooling
Filter
Filter
Refrigerant pipe connection port diameter
MODEL GAS LIQUID
ARNU07GB1G2 12.7(1/2) 6.35(1/4)
ARNU09GB1G2 12.7(1/2) 6.35(1/4)
ARNU12GB1G2 12.7(1/2) 6.35(1/4)
ARNU15GB1G2 12.7(1/2) 6.35(1/4)
ARNU18GB2G2 12.7(1/2) 6.35(1/4)
ARNU24GB2G2 15.88(5/8) 9.52(3/8)
[Unit: mm(inch)]
LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor
Indoor unit
Ceiling Concealed Duct
- Low Static
5-6 5-6
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
5. Wiring Diagrams
CONNECTOR NUMBER SPEC. DESCRIPTION
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-ROOM Room sensor Room thermistor
CN-REMO Remote controller Remote control line
CN-FLOAT Float switch input Float switch sensing
CN-EEV EEV output EEV control output
CN-D/PUMP Drain pump output AC output for drain pump
CN-OPTION Option PWB. Communication between main and option
CN-COM Communication Communication between indoor and outdoor
CN-D/PUMP Drain pump output AC output for drain pump
CN-POWER AC power supply AC power line input for indoor controller
CN-ZONE Zone Controller Zone control line
CN-DISPLAY RF Remote controller RF remote control line
CN-CC Dry contact Dry contact line
B1/B2 Chassis
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor
CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.
Indoor unit
Ceiling Concealed Duct
- Low Static
5-7 5-7
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
6. Capacity Tables
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.7 2.8
12 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.7 2.8
14 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.6 2.7
16 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.6 2.7
18 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.5 2.7
20 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.4 2.6
21 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.4 2.6
23 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.3 2.6
25 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.2 2.8 4.3 2.5
27 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.7 4.2 2.5
29 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.7 4.2 2.5
31 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.6 4.1 2.4
33 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.6 4.0 2.4
35 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 3.9 2.6 4.0 2.3
37 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.8 2.5 3.9 2.3
39 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.7 2.5 3.8 2.3
2.8
3.6
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
10 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.9 1.7
12 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.9 1.7
14 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.8 1.7
16 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.8 1.6
18 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.7 1.6
20 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.7 1.6
21 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.7 1.6
23 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.6 1.6
25 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.6 1.5
27 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.5 1.7 2.6 1.5
29 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.5 1.6 2.5 1.5
31 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.5 1.6 2.5 1.5
33 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.4 1.6 2.5 1.5
35 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.4 1.6 2.4 1.4
37 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.6 2.3 1.5 2.4 1.4
39 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.2 1.6 2.3 1.5 2.3 1.4
10 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.7 2.2
12 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.6 2.1
14 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.6 2.1
16 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.5 2.1
18 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.5 2.1
20 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
21 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
23 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
25 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.3 2.2 3.3 2.0
27 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.2 2.1 3.3 1.9
29 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.2 2.1 3.2 1.9
31 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.1 2.1 3.2 1.9
33 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.1 2.0 3.1 1.9
35 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.0 2.0 3.1 1.8
37 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 2.9 2.1 3.0 1.9 3.0 1.8
39 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 2.9 2.0 2.9 1.9 3.0 1.8
2.2
6.1 Cooling Capacity
Cooling capacity
Indoor unit
Ceiling Concealed Duct
- Low Static
5-8 5-8
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
Cooling capacity
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.3 5.4
12 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.2 5.3
14 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.1 5.2
16 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.0 5.2
18 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.8 5.1
20 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.7 5.0
21 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.7 5.0
23 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.5 4.9
25 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.4 5.4 8.4 4.8
27 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.2 5.2 8.3 4.8
29 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.1 5.2 8.2 4.7
31 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.0 5.1 8.1 4.6
33 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 7.8 5.0 7.9 4.6
35 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 7.7 4.9 7.8 4.5
37 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.4 5.1 7.5 4.8 7.7 4.4
39 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.2 5.0 7.4 4.7 7.6 4.4
5.6
7.1
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
10 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.9 3.5
12 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.8 3.5
14 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.8 3.4
16 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.7 3.4
18 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.6 3.3
20 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.5 3.3
21 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.5 3.3
23 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.4 3.2
25 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.3 3.2
27 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.3 3.1
29 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.2 3.1
31 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.1 3.0
33 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.0 3.0
35 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.0 2.9
37 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 4.9 2.9
39 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 4.8 2.8
10 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.4 4.2
12 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.3 4.2
14 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.2 4.1
16 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.1 4.1
18 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.0 4.0
20 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 6.9 4.0
21 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 6.8 3.9
23 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 6.7 3.9
25 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.6 4.2 6.6 3.8
27 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.4 4.1 6.6 3.8
29 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.4 4.1 6.5 3.7
31 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.3 4.0 6.4 3.7
33 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.2 3.9 6.3 3.6
35 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.0 3.9 6.2 3.5
37 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 5.8 4.0 5.9 3.8 6.1 3.5
39 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 5.7 3.9 5.8 3.7 6.0 3.4
4.5
Indoor unit
Ceiling Concealed Duct
- Low Static
5-9 5-9
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
6.2 Heating Capacity
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 1.7 1.7 1.7 1.7 1.7 1.7
-18.8 -19.0 1.7 1.7 1.7 1.7 1.7 1.7
-16.7 -17.0 1.8 1.8 1.8 1.8 1.8 1.8
-14.7 -15.0 1.9 1.9 1.7 1.9 1.9 1.9
-12.6 -13.0 2.0 2.0 1.8 2.0 2.0 2.0
-10.5 -11.0 2.1 2.1 1.9 2.1 2.1 2.1
-9.5 -10.0 2.2 2.2 1.9 2.2 2.2 2.1
-8.5 -9.1 2.2 2.2 2.0 2.2 2.2 2.1
-7.0 -7.6 2.3 2.3 2.0 2.2 2.2 2.2
-5.0 -5.6 2.4 2.4 2.1 2.3 2.3 2.2
-3.0 -3.7 2.5 2.5 2.2 2.4 2.4 2.2
0.0 -0.7 2.6 2.6 2.3 2.4 2.4 2.2
3.0 2.2 2.8 2.7 2.4 2.4 2.4 2.2
5.0 4.1 2.8 2.7 2.5 2.4 2.4 2.2
7.0 6.0 2.9 2.7 2.5 2.4 2.4 2.2
9.0 7.9 2.9 2.7 2.5 2.4 2.4 2.2
11.0 9.8 2.9 2.7 2.5 2.4 2.4 2.2
13.0 11.8 2.9 2.7 2.5 2.4 2.4 2.2
15.0 13.7 2.9 2.7 2.5 2.4 2.4 2.2
-19.8 -20.0 2.1 2.1 2.1 2.1 2.1 2.1
-18.8 -19.0 2.2 2.2 2.2 2.2 2.2 2.2
-16.7 -17.0 2.3 2.3 2.3 2.3 2.3 2.3
-14.7 -15.0 2.5 2.4 2.2 2.4 2.4 2.4
-12.6 -13.0 2.6 2.6 2.3 2.6 2.6 2.6
-10.5 -11.0 2.7 2.7 2.4 2.7 2.7 2.7
-9.5 -10.0 2.8 2.8 2.5 2.8 2.8 2.7
-8.5 -9.1 2.8 2.8 2.5 2.8 2.8 2.7
-7.0 -7.6 2.9 2.9 2.6 2.8 2.8 2.8
-5.0 -5.6 3.0 3.0 2.7 3.0 3.0 2.8
-3.0 -3.7 3.2 3.2 2.8 3.1 3.0 2.8
0.0 -0.7 3.4 3.4 3.0 3.1 3.0 2.8
3.0 2.2 3.6 3.4 3.1 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.7 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.7 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.7 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.7 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.7 3.4 3.2 3.1 3.0 2.8
-19.8 -20.0 2.7 2.7 2.7 2.6 2.6 2.6
-18.8 -19.0 2.8 2.8 2.8 2.8 2.7 2.7
-16.7 -17.0 2.9 2.9 2.9 2.9 2.9 2.9
-14.7 -15.0 3.1 3.0 2.7 3.0 3.0 3.0
-12.6 -13.0 3.2 3.2 2.9 3.2 3.2 3.2
-10.5 -11.0 3.4 3.4 3.0 3.4 3.4 3.4
-9.5 -10.0 3.4 3.4 3.1 3.4 3.4 3.4
-8.5 -9.1 3.5 3.5 3.2 3.5 3.5 3.4
-7.0 -7.6 3.6 3.6 3.3 3.6 3.6 3.5
-5.0 -5.6 3.8 3.8 3.4 3.7 3.7 3.5
-3.0 -3.7 4.0 4.0 3.5 3.9 3.8 3.5
0.0 -0.7 4.2 4.2 3.7 3.9 3.8 3.5
3.0 2.2 4.4 4.3 3.9 3.9 3.8 3.5
5.0 4.1 4.5 4.3 4.0 3.9 3.8 3.5
7.0 6.0 4.6 4.3 4.0 3.9 3.8 3.5
9.0 7.9 4.6 4.3 4.0 3.9 3.8 3.5
11.0 9.8 4.6 4.3 4.0 3.9 3.8 3.5
13.0 11.8 4.6 4.3 4.0 3.9 3.8 3.5
15.0 13.7 4.6 4.3 4.0 3.9 3.8 3.5
2.2
2.8
3.6
Notes:
TC: Total Capacity(kW)
Heating capacity
Indoor unit
Ceiling Concealed Duct
- Low Static
5-10 5-10
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 3.4 3.4 3.4 3.3 3.3 3.3
-18.8 -19.0 3.5 3.5 3.5 3.5 3.4 3.4
-16.7 -17.0 3.7 3.7 3.7 3.7 3.7 3.6
-14.7 -15.0 3.9 3.8 3.4 3.8 3.8 3.8
-12.6 -13.0 4.1 4.1 3.6 4.0 4.0 4.0
-10.5 -11.0 4.3 4.3 3.8 4.3 4.2 4.2
-9.5 -10.0 4.3 4.3 3.9 4.3 4.3 4.3
-8.5 -9.1 4.4 4.4 4.0 4.4 4.4 4.3
-7.0 -7.6 4.6 4.6 4.1 4.4 4.4 4.4
-5.0 -5.6 4.8 4.8 4.3 4.6 4.6 4.4
-3.0 -3.7 5.0 5.0 4.4 4.8 4.7 4.4
0.0 -0.7 5.3 5.3 4.6 4.8 4.7 4.4
3.0 2.2 5.6 5.4 4.9 4.8 4.7 4.4
5.0 4.1 5.6 5.4 5.0 4.8 4.7 4.4
7.0 6.0 5.8 5.4 5.0 4.8 4.7 4.4
9.0 7.9 5.8 5.4 5.0 4.8 4.7 4.4
11.0 9.8 5.8 5.4 5.0 4.8 4.7 4.4
13.0 11.8 5.8 5.4 5.0 4.8 4.7 4.4
15.0 13.7 5.8 5.4 5.0 4.8 4.7 4.4
-19.8 -20.0 4.2 4.2 4.2 4.2 4.2 4.2
-18.8 -19.0 4.3 4.3 4.3 4.3 4.3 4.3
-16.7 -17.0 4.6 4.6 4.6 4.6 4.6 4.5
-14.7 -15.0 4.9 4.8 4.3 4.8 4.8 4.8
-12.6 -13.0 5.1 5.1 4.5 5.0 5.0 5.0
-10.5 -11.0 5.4 5.4 4.8 5.4 5.3 5.3
-9.5 -10.0 5.4 5.4 4.9 5.4 5.4 5.4
-8.5 -9.1 5.5 5.5 5.0 5.5 5.5 5.4
-7.0 -7.6 5.7 5.7 5.1 5.6 5.6 5.5
-5.0 -5.6 6.0 6.0 5.4 5.8 5.8 5.5
-3.0 -3.7 6.2 6.2 5.5 6.1 5.9 5.5
0.0 -0.7 6.6 6.6 5.8 6.1 5.9 5.5
3.0 2.2 7.0 6.7 6.2 6.1 5.9 5.5
5.0 4.1 7.1 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.2 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.2 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.2 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.2 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.2 6.7 6.3 6.1 5.9 5.5
-19.8 -20.0 5.4 5.4 5.4 5.3 5.3 5.3
-18.8 -19.0 5.5 5.5 5.5 5.5 5.4 5.4
-16.7 -17.0 5.8 5.8 5.8 5.8 5.8 5.8
-14.7 -15.0 6.2 6.1 5.5 6.1 6.1 6.1
-12.6 -13.0 6.5 6.5 5.8 6.4 6.4 6.4
-10.5 -11.0 6.8 6.8 6.0 6.8 6.7 6.7
-9.5 -10.0 6.9 6.9 6.2 6.9 6.9 6.8
-8.5 -9.1 7.0 7.0 6.3 7.0 7.0 6.8
-7.0 -7.6 7.3 7.3 6.5 7.1 7.1 7.0
-5.0 -5.6 7.6 7.6 6.8 7.4 7.4 7.0
-3.0 -3.7 7.9 7.9 7.0 7.7 7.5 7.0
0.0 -0.7 8.4 8.4 7.4 7.8 7.5 7.0
3.0 2.2 8.9 8.6 7.8 7.8 7.5 7.0
5.0 4.1 9.0 8.6 8.0 7.8 7.5 7.0
7.0 6.0 9.2 8.6 8.0 7.8 7.5 7.0
9.0 7.9 9.2 8.6 8.0 7.8 7.5 7.0
11.0 9.8 9.2 8.6 8.0 7.8 7.5 7.0
13.0 11.8 9.2 8.6 8.0 7.8 7.5 7.0
15.0 13.7 9.2 8.6 8.0 7.8 7.5 7.0
4.5
5.6
7.1
Notes:
TC: Total Capacity(kW)
Heating capacity
Indoor unit
Ceiling Concealed Duct
- Low Static
5-11 5-11
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
7. External Static Pressure (E.S.P) & Air Flow
Note :
1. The above table shows the correlation between the air rates and E.S.P.
Setting Value
60 6.02 2.25 0.61 - -
65 6.95 3.32 0.73 0.54 0.48
70 7.69 5.16 1.19 0.65 0.56
75 8.46 6.93 2.42 0.77 0.63
80 9.5 7.37 3.4 0.87 0.72
85 10.35 8.72 5.33 1.35 0.88
90 10.81 9.66 6.75 3.15 0.98
95 11.57 10.31 8.56 4.73 1.03
100 12.58 11.22 9.75 7.46 2.31
105 13.31 12.27 10.89 8.64 5.01
110 14.2 13.24 12.15 10.49 7.7
115 14.82 13.92 12.64 11.16 9.48
0(0) 1(10) 2(20) 3(29) 4(39)
Static Pressure(mmAq(Pa))
Setting Value
65 10.07 6.9 0.82 - -
70 11.39 8.49 2.2 - -
75 12.01 9.79 4.2 - -
80 13.21 11.03 5.92 0.92 -
85 14.24 12.36 9.41 2.1 -
90 15.04 13.34 10.8 5.29 1.01
95 16.02 14.63 12.5 7.59 1.34
100 17.11 15.56 13.66 11.53 5.35
105 17.99 16.53 15.17 12.35 7.67
110 19.04 17.71 16.22 14.23 10.45
115 19.77 18.62 17.1 15.23 13.25
120 20.94 19.92 18.56 16.98 14.66
125 21.97 20.56 19.25 17.68 16.06
130 22.83 21.98 20.75 19.32 17.73
0(0) 1(10) 2(20) 3(29) 4(39)
Static Pressure(mmAq(Pa))
ARNU07GB1G2, ARNU09GB1G2, ARNU12GB1G2, ARNU15GB1G2
ARNU18GB2G2, ARNU24GB2G2
(Unit: CMM)
(Unit: CMM)
Indoor unit
Ceiling Concealed Duct
- Low Static
5-12 5-12
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
ARNU07GB1G2, ARNU09GB1G2, ARNU12GB1G2, ARNU15GB1G2
ARNU18GB2G2, ARNU24GB2G2
Capacity Mode Set value
18k
High
(factory set)
High
(factory set)
HI 110
Mid 101
Low 93
HI 95
Mid 84
Low 75
HI 125
Mid 115
Low 105
HI 110
Mid 100
Low 90
16
14
12
16
14
12
19
17
15
19
17
15
2(20)
0(0)
2(20)
0(0)
- 4(39)
- 4(39)
- 4(39)
- 4(39)
Standard
Standard
24k
Standard
ESP(mmAq(Pa))
CMM
Lower Limit of External
Static Pressure(mmAq(Pa))
Upper Limit of External
Static Pressure(mmAq(Pa))
Capacity Mode Set value
7k
High
(factory set)
High
(factory set)
High
(factory set)
High
(factory set)
HI 94
Mid 92
Low 86
HI 75
Mid 69
Low 62
HI 99
Mid 94
Low 92
HI 82
Mid 75
Low 69
HI 103
Mid 99
Low 94
HI 89
Mid 80
Low 75
HI 107
Mid 105
Low 99
HI 95
Mid 89
Low 82
8.5
7.5
6.5
8.5
7.5
6.5
9.5
8.5
7.5
9.5
8.5
7.5
10.5
9.5
8.5
10.5
9.5
8.5
11.5
10.5
9.5
11.5
10.5
9.5
2(20)
0(0)
2(20)
0(0)
2(20)
0(0)
2(20)
0(0)
- 4(39)
- 4(39)
- 4(39)
- 4(39)
- 4(39)
- 4(39)
- 4(39)
- 4(39)
Standard
Standard
Standard
Standard
9k
12k
15k
Standard
ESP(mmAq(Pa))
CMM
Lower Limit of External
Static Pressure(mmAq(Pa))
Upper Limit of External
Static Pressure(mmAq(Pa))
Indoor unit
Ceiling Concealed Duct
- Low Static
5-13 5-13
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
8. Electric Characteristics
Symbols:
MCA : Min, Circuit Amps(A)
MFA : Max. Fuse Amps(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amps(A)
IFM : Indoor Fan Motor
Note :
1. Voltage range
Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above
the listed range limits,
2. Maximum allowable voltage unbalance between phases is 2%
3. MCA/MFA
MCA=1.25 x FLA
MFA 4 x FLA
(Next lower standard fuse rating. Min. 15A)
4. Select wire size based on the MCA
5. Instead of fuse, use Circuit Breaker.
Units
Model Type Hz Volts Voltage Range
ARNU07GB1G2 B1 0.22 15 0.028 0.17 30 30
ARNU09GB1G2 B1 0.22 15 0.028 0.17 30 30
ARNU12GB1G2 B1
50 220-240
Max:264 0.22 15 0.028 0.17 30 30
ARNU15GB1G2 B1 Min:198 0.22 15 0.028 0.17 30 30
ARNU18GB2G2 B2 0.55 15 0.076 0.44 80 80
ARNU24GB2G2 B2 0.55 15 0.076 0.44 80 80
ARNU07GB1G2 B1 0.22 15 0.028 0.17 30 30
ARNU09GB1G2 B1 0.22 15 0.028 0.17 30 30
ARNU12GB1G2 B1
60 220
Max:242 0.22 15 0.028 0.17 30 30
ARNU15GB1G2 B1 Min:198 0.22 15 0.028 0.17 30 30
ARNU18GB2G2 B2 0.55 15 0.076 0.44 80 80
ARNU24GB2G2 B2 0.55 15 0.076 0.44 80 80
Power Supply IFM Input(W)
MCA MFA kW FLA Cooling Heating
Indoor unit
Ceiling Concealed Duct
- Low Static
5-14 5-14
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
9. Sound Levels
Overall
Sound Pressure Level
Notes:
- Sound measured at 1.5m away from the center of the unit.
- Data is valid at free field condition
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.
Model Name
ARNU07GB1G2
ARNU09GB1G2
ARNU12GB1G2
ARNU15GB1G2
ARNU18GB2G2
ARNU24GB2G2
Sound Levels dB(A)
H M L
33
34
35
38
40
43
32
33
34
37
37
40
29
32
33
36
34
37
1
.
5
m
Ceiling
2.0m
Microphone
ARNU07GB1G2
ARNU15GB1G2
ARNU09GB1G2 ARNU12GB1G2
ARNU18GB2G2 ARNU24GB2G2
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
Approximate
Hearing
Threshold
Approximate
Hearing
Threshold
Approximate
Hearing
Threshold
Approximate
Hearing
Threshold
Approximate
Hearing
Threshold
Indoor unit
Ceiling Concealed Duct
- Low Static
5-15 5-15
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
10. Installation
Please read the instruction sheets completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
Required Parts Required Tools
Connecting cable
Pipes: Gas side
Liquid side
Hanging Bolt
(W 3/8 or M10 length 650mm)
Insulated drain hose
Additional Drain hose
Level
Screw driver
Electric drill
Hole core drill
Flaring Tool set
Torque Wrenches
Hexagonal Wrench
Gas-leak detector
Thermometer
10.1 Selection of the best location
Install the air conditioner in the location that satisfies
the
following conditions.
The place shall easily bear a load exceeding four
times the indoor units weight.
The place shall be able to inspect the unit as given in
the
figure.
The place where the unit shall be leveled.
The place shall allow easy water drainage.(Suitable
dimension H is necessary to get a slope to drain as
figure.)
The place shall easily connect with the outdoor unit.
The place where the unit is not affected by an electri-
cal noise.
The place where air circulation in the room will be
good .
There should not be any heat source or steam near
the unit.
The servicing inspection hole in the ceiling should be
as large as the product.
The sel ecti on of the servi ci ng hol e shoul d be
approved by the customer.
H
600 600
Top view
(unit: mm)
Front view
Inspection hole
(600X600)
Control box
Minimum height for
motor replacement.
Less than 20cm
Hole size should be
more than the size of IDU.
Insufficient space.
Difficult for servicing
20cm to 100cm 2
Sufficient space in the
ceiling for servicing.
More than 100cm 1
Remarks
Distance between
False ceiling & Actual ceiling
Number of
Inspection hole
[Inspection Hole Standard]
Indoor unit
Ceiling Concealed Duct
- Low Static
5-16 5-16
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
10.2 Ceiling dimension and hanging bolt
location
I Installation of Unit
Install the unit above the ceiling correctly.
Apply a joint-canvas between the unit and duct to absorb
unnecessary vibration.
Install the unit leaning to a drainage hole side as a figure
for easy water drainage.
A place where the unit will be leveled and that can sup-
port the weight of the unit.
A place where the unit can withstand its vibration.
A place where service can be easily performed.
CASE 1
POSITION OF SUSPENSION BOLT
CASE 2
POSITION OF CONSOLE BOLT
M10 Nut
M10 washer
X 4
X 4
M10 Nut
M10 washer X 4
X 8
NOTE:
Throughly study the following installation locations:
1. In such places as restaurants and kitchens, considerable amount of oil steam and flour adhere to the fan, the fin of the heat
exchanger, resulting in heat exchange reduction, spraying, dispersing of water drops, etc.
In these cases, take the following actions:
Make sure that the ventilation fan for smoke-collecting hood on a cooking table has sufficient capacity so that it draws oily
steam which should not flow into the suction of the air conditioner.
Make enough distance from a cooking room to install the air conditioner in such a place where it may not suck in oil steam.
2. Avoid installing air conditioner in such circumstances where cutting oil mist or iron powder is in suspension in factories, etc.
3. Avoid places where inflammable gas is generated, flows in, is stored or vented.
4. Avoid places where sulfurous acid gas or corrosive gas is generated.
5. Avoid places near high frequency generators.
Indoor unit
Ceiling Concealed Duct
- Low Static
5-17 5-17
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
10.4 Indoor Unit Drain Piping
Drain piping must have down-slope (1/50 to 1/100): be sure not to pro-
vide up-and-down slope to prevent reversal flow.
During drain piping connection, be careful not to exert extra force on the
drain port on the indoor unit.
The outside diameter of the drain connection on the indoor unit is 32mm.
Be sure to install heat insulation on the drain piping.
10.3 Checking the Drainage
Spray one or two glasses of water on the evaporator.
Ensure that water flows drain hose of indoor unit without any leakage.
Piping material: Polyvinyl chloride pipe inner
diometes 25mm and pipe fittings
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:
Connect the main drain pipe to the exterior and leave it pro-
visionally until the test comes to an end.
Feed water to the flexible drain hose and check the piping
for leakage.
Be sure to check the drain pump for normal operating and
noise when electrical wiring is complete.
When the test is complete, connect the flexible drain hose to
the drain port on the indoor unit.
Heat insulation material: Polyethylene foam with
thickness more than 8 mm.
Drain test
Maintenance
drain port
Upward
routing
not allowed
Pipe clamp
Indoor unit
1/50~1/100
MAX 700mm
Feed water
Drain Pump
Drain pan
Flexible drain hose
(accessory)
Main
drain pipe
Glue the joint
Drain
port
Drain hose connection
Use the clip (accessory)
CAUTION
The supplied flexible drain hose should not be strained.
A strained hose may cause leakage of water.
1/50~1/100 slope
Hanger
distance
Hanger Bracket
M
a
x

7
0
0
m
m
Flexible drain hose
Insulation
Metal
clamp
Max 300mm
1~15m
Indoor unit
Ceiling Concealed Duct
- Low Static
5-18 5-18
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
10.5 Ground drain piping
a) It is standard work practice to make connections to the main pipe from above. The pipe down from the
combination should be as large as possible.
10.6 Use of an auxiliary drain hose(flexible)
a) To connect drain pipe to the drain socket on the indoor unit, an auxiliary flexible drain hose should be
used. auxiliary flexible drain hose allows that the drain pipe can be connected to the socket without break-
ing by excessive strain.
Important points
- The drain pipe should be at least equal in size to that of the indoor unit.
- The drain pipe is thermally insulated to prevent the formation of condensation inside the pipe.
- The drain up mechanism should be fitted before the indoor unit is installed and when the electricity has
been connected some water should be added to the drain pan and the drain pump to check and see if it
is functioning correctly.
- All connections should be secure. (Special care is needed with PVC pipe)
- Insulate auxiliary drain hose with thermal insulation band.
b) The pipe work should be kept as short as possible and the number of indoor units per group kept to a
minimum.
Face piping
downward
Vent pipe
Face the vent pipe mouth downward to keep
foreign matter from penetrating the system
Metal clamp
Drain pan
Metal clamp
Thermal insulation(bend area)
Auxiliary drain hose
Thermal insulation (drain pipe area)
Indoor unit
Ceiling Concealed Duct
- Low Static
5-19 5-19
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
WIRED REMOTE CONTROLLER INSTALLATION
Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average tempera-
ture.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
Fig.1 Typical locations for remote controller
5feet
(1.5meters)
no
no
no
yes
Remote Controller
TEMP
Remote Controller
TEMP
Remote Controller
TEMP
Indoor unit
Ceiling Concealed Duct
- Low Static
5-20 5-20
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

L
o
w

S
t
a
t
i
c
11. Accessories
4 EA
Name
Quantity
Shape
for gas pipe
for liquid pipe
Clamp metal
2 EA
Insulation for
fitting
1 SET
Drain hose
1 EA
Clamp
(Tie Wrap)
8 EA
Washer for
hanging backet
(Other)
Standard Accessories
Owner's manual
Installation manual
Use only those accessories (Standard or optional) which have designated specifications.
CAUTION
Indoor unit
Ceiling Concealed Duct
- Built in
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. External Static Pressure (E.S.P) & Air Flow
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories
Ceiling Concealed Duct
(Built in)
Indoor unit
Ceiling Concealed Duct
- Built in
6-1 6-1
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
1. List of Functions
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Air flow
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Air purifying Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
Installation
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Reliability Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Convenience Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Individual Simple wired remote controller
control Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Special
Zone control
function kit
CTIE
Electro thermostat
1
-
-
-
-
3 / 3 / 3
-
-
-
-
X
X
O
O
O
X
-
O
O
O
O(Heat recovery)
X
O(Heat pump or Cooling only)
O
O
-
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
X
Accessory
Accessory
-
-
Function Category
ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
O : Applied X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.
Indoor unit
Ceiling Concealed Duct
- Built in
6-2 6-2
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
2. Specification
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification
4. EEV: Electronic Expansion Valve
5. To be added for more available Models
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Type
Accessory
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Air Flow Rate(H / M / L) CMM
(High Mode-factor set) cfm
Fan External Static Pressure mmAq(Pa)
Air Flow Rate(H / M / L) CMM
(Standard Mode) cfm
External Static Pressure mmAq(Pa)
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Ceiling Concealed Duct (Built-in)
PBSGB30/PBSC30 PBSGB30/PBSC30 PBSGB30/PBSC30
ARNU07GB3G2 ARNU09GB3G2 ARNU12GB3G2
2.2 2.8 3.6
1,900 2,400 3,100
7,500 9,600 12,300
2.5 3.2 4.0
2,200 2,800 3,400
8,500 10,900 13,600
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
820 x 575 x 190 820 x 575 x 190 820 x 575 x 190
32.3 x 22.6 x 7.5 32.3 x 22.6 x 7.5 32.3 x 22.6 x 7.5
2 x 11 x 21 2 x 11 x 21 2 x 11 x 21
0.16 0.16 0.16
Sirocco Fan Sirocco Fan Sirocco Fan
30 30 30
0.15 0.15 0.15
8.0 / 6.5 / 5.5 9.0 / 7.0 / 6.0 10.0 / 8.0 / 6.5
283 / 229 / 194 318 / 247 / 212 353 / 283 / 229
2(20) 2(20) 2(20)
8.0 / 6.5 / 5.5 9.0 / 7.0 / 6.0 10.0 / 8.0 / 6.5
283 / 229 / 194 318 / 247 / 212 353 / 283 / 229
0(0) 0(0) 0(0)
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene
- - -
Fuse, Thermal Fuse for Fan Motor Fuse, Thermal Fuse for Fan Motor Fuse, Thermal Fuse for Fan Motor
6.35(1/4) 6.35(1/4) 6.35(1/4)
12.7(1/2) 12.7(1/2) 12.7(1/2)
25.4(1) 25.4(1) 25.4(1)
21(46.3) 21(46.3) 21(46.3)
33 / 32 / 29 34 / 33 / 32 35 / 34 / 33
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Indoor unit
Ceiling Concealed Duct
- Built in
6-3 6-3
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification
4. EEV: Electronic Expansion Valve
5. To be added for more available Models
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Type
Accessory
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Air Flow Rate(H / M / L) CMM
(High Mode-factor set) cfm
Fan External Static Pressure mmAq(Pa)
Air Flow Rate(H / M / L) CMM
(Standard Mode) cfm
External Static Pressure mmAq(Pa)
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Ceiling Concealed Duct (Built-in)
PBSGB30/PBSC30 PBSGB40/PBSC40 PBSGB40/PBSC40
ARNU15GB3G2 ARNU18GB4G2 ARNU24GB4G2
4.5 5.6 7.1
3,900 4,800 6,100
15,400 19,100 24,200
5.0 6.3 8.0
4,300 5,400 6,900
17,100 21,500 27,300
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
820 x 575 x 190 1,100 x 575 x 190 1,100 x 575 x 190
32.3 x 22.6 x 7.5 32.3 x 22.6 x 7.5 32.3 x 22.6 x 7.5
2 x 11 x 21 3 x 10 x 18 3 x 10 x 18
0.16 0.23 0.23
Sirocco Fan Sirocco Fan Sirocco Fan
30 80 80
0.15 0.38 0.38
11.0 / 10.0 / 8.0 14.0 / 12.0 / 10.0 17.0 / 15.0 / 10.0
388 / 353 / 283 494 / 424 / 353 600 / 530 / 353
2(20) 2(20) 2(20)
11.0 / 10.0 / 8.0 14.0 / 12.0 / 10.0 17.0 / 15.0 / 10.0
388 / 353 / 283 494 / 424 / 353 600 / 530 / 353
0(0) 0(0) 0(0)
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene
- - -
Fuse, Thermal Fuse for Fan Motor Fuse, Thermal Fuse for Fan Motor Fuse, Thermal Fuse for Fan Motor
6.35(1/4) 6.35(1/4) 9.52(3/8)
12.7(1/2) 12.7(1/2) 15.88(5/8)
25.4(1) 25.4(1) 25.4(1)
21(46.3) 26(57.3) 26(57.3)
41 / 40 / 37 43 / 40 / 37 46 / 43 / 37
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Indoor unit
Ceiling Concealed Duct
- Built in
6-4 6-4
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
3. Dimensions
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

B
3
/
B
4
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t

(
B
u
i
l
t

i
n
)
A
R
N
U
0
7
G
B
3
G
2
+
P
B
S
G
B
3
0
(
A
c
c
'
y
)
,

P
B
S
C
3
0
(
A
c
c
'
y
)
A
R
N
U
0
9
G
B
3
G
2
+
P
B
S
G
B
3
0
(
A
c
c
'
y
)
,

P
B
S
C
3
0
(
A
c
c
'
y
)
A
R
N
U
1
2
G
B
3
G
2
+
P
B
S
G
B
3
0
(
A
c
c
'
y
)
,

P
B
S
C
3
0
(
A
c
c
'
y
)
A
R
N
U
1
5
G
B
3
G
2
+
P
B
S
G
B
3
0
(
A
c
c
'
y
)
,

P
B
S
C
3
0
(
A
c
c
'
y
)
A
R
N
U
1
8
G
B
4
G
2
+
P
B
S
G
B
4
0
(
A
c
c
'
y
)
,

P
B
S
C
4
0
(
A
c
c
'
y
)
A
R
N
U
2
4
G
B
4
G
2
+
P
B
S
G
B
4
0
(
A
c
c
'
y
)
,

P
B
S
C
4
0
(
A
c
c
'
y
)
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
W
i
t
h

S
u
c
t
i
o
n

G
r
i
l
l
e
W
i
t
h

S
u
c
t
i
o
n

G
r
i
l
l
e

&

S
u
c
t
i
o
n

C
a
n
v
a
s
B
3
/
B
4
A
W
i
t
h

S
u
c
t
i
o
n

G
r
i
l
l
e
&

S
u
c
t
i
o
n

C
a
n
v
a
s

W
i
t
h

S
u
c
t
i
o
n

G
r
i
l
l
e

B
D
C
E
F
G
B
t
u
/
h
A
7
,
9
,
1
2
,
1
5
k
8
2
0
1
8
,
2
4
k
1
1
0
0
B
C
D
P
B
S
G
B
3
0
9
1
0
3
5
9
5
6
P
B
S
G
B
4
0
1
1
8
8
3
5
9
5
6
E
F
G
P
B
S
C
3
0
8
2
1
2
7
4
4
2
~
2
5
0
P
B
S
C
4
0
1
1
0
0
2
7
4
4
2
~
2
5
0
2 5 0
1 9 0
6 1 8
3 8 8
1 9 0
5 0 0 ( M a x )
5 7 5
3 8 8
1
9
0
6
5
6
0
2 7 7
2 1 6
2 4
N
a
m
e
1
L
i
q
u
i
d

p
i
p
e

c
o
n
n
e
c
t
i
o
n
2
G
a
s

p
i
p
e

c
o
n
n
e
c
t
i
o
n

3
D
r
a
i
n

p
i
p
e

c
o
n
n
e
c
t
i
o
n

4
P
o
w
e
r

s
u
p
p
l
y

c
o
n
n
e
c
t
i
o
n

5
A
i
r

s
u
c
t
i
o
n

6
A
i
r

d
i
s
c
h
a
r
g
e
N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
(
u
n
i
t

:

m
m
)
U
n
i
t

s
i
z
e
(
7
k
,
9
k
,
1
2
k
,
1
5
k
,
1
8
k
)
:

6
.
3
5
U
n
i
t

s
i
z
e
(
2
4
k
)
:

9
.
5
2
U
n
i
t

s
i
z
e
(
7
k
,
9
k
,
1
2
k
,
1
5
k
,
1
8
k
)
:

1
2
.
7
U
n
i
t

s
i
z
e
(
2
4
k
)
:

1
5
.
8
8
6
5
13
4
2
Indoor unit
Ceiling Concealed Duct
- Built in
6-5 6-5
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
4. Piping Diagrams
Heat Exchanger
Sirocco Fan
Th3
Th2
Th1
lndoor unit
EEV
:Heating
:Cooling
Filter
Filter
Refrigerant pipe connection port diameter
MODEL GAS LIQUID
ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) 12.7(1/2) 6.35(1/4)
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) 12.7(1/2) 6.35(1/4)
ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) 12.7(1/2) 6.35(1/4)
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) 12.7(1/2) 6.35(1/4)
ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y) 12.7(1/2) 6.35(1/4)
ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y) 15.88(5/8) 9.52(3/8)
[Unit: mm(inch)]
LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor
Indoor unit
Ceiling Concealed Duct
- Built in
6-6 6-6
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
5. Wiring Diagrams
B3/B4 Chassis
CONNECTOR NUMBER SPEC. DESCRIPTION
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-ROOM Room sensor Room thermistor
CN-REMO Remote controller Remote control line
CN-FLOAT Float switch input Float switch sensing
CN-EEV EEV output EEV control output
CN-D/PUMP Drain pump output AC output for drain pump
CN-OPTION Option PWB. Communication between main and option
CN-COM Communication Communication between indoor and outdoor
CN-D/PUMP Drain pump output AC output for drain pump
CN-POWER AC power supply AC power line input for indoor controller
CN-ZONE Zone Controller Zone control line
CN-DISPLAY RF Remote controller RF remote control line
CN-CC Dry contact Dry contact line
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor
CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.
Indoor unit
Ceiling Concealed Duct
- Built in
6-7 6-7
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
6. Capacity Tables
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
6.1 Cooling Capacity
Cooling capacity
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.7 2.8
12 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.7 2.8
14 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.6 2.7
16 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.6 2.7
18 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.5 2.7
20 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.4 2.6
21 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.4 2.6
23 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.3 2.6
25 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.2 2.8 4.3 2.5
27 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.7 4.2 2.5
29 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.7 4.2 2.5
31 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.6 4.1 2.4
33 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.6 4.0 2.4
35 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 3.9 2.6 4.0 2.3
37 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.8 2.5 3.9 2.3
39 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.7 2.5 3.8 2.3
2.8
3.6
10 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.9 1.7
12 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.9 1.7
14 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.8 1.7
16 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.8 1.6
18 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.7 1.6
20 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.7 1.6
21 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.7 1.6
23 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.6 1.6
25 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.6 1.5
27 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.5 1.7 2.6 1.5
29 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.5 1.6 2.5 1.5
31 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.5 1.6 2.5 1.5
33 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.4 1.6 2.5 1.5
35 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.4 1.6 2.4 1.4
37 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.6 2.3 1.5 2.4 1.4
39 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.2 1.6 2.3 1.5 2.3 1.4
10 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.7 2.2
12 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.6 2.1
14 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.6 2.1
16 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.5 2.1
18 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.5 2.1
20 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
21 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
23 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
25 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.3 2.2 3.3 2.0
27 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.2 2.1 3.3 1.9
29 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.2 2.1 3.2 1.9
31 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.1 2.1 3.2 1.9
33 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.1 2.0 3.1 1.9
35 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.0 2.0 3.1 1.8
37 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 2.9 2.1 3.0 1.9 3.0 1.8
39 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 2.9 2.0 2.9 1.9 3.0 1.8
2.2
Indoor unit
Ceiling Concealed Duct
- Built in
6-8 6-8
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
Cooling capacity
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.3 5.4
12 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.2 5.3
14 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.1 5.2
16 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.0 5.2
18 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.8 5.1
20 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.7 5.0
21 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.7 5.0
23 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.5 4.9
25 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.4 5.4 8.4 4.8
27 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.2 5.2 8.3 4.8
29 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.1 5.2 8.2 4.7
31 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.0 5.1 8.1 4.6
33 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 7.8 5.0 7.9 4.6
35 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 7.7 4.9 7.8 4.5
37 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.4 5.1 7.5 4.8 7.7 4.4
39 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.2 5.0 7.4 4.7 7.6 4.4
5.6
7.1
10 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.9 3.5
12 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.8 3.5
14 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.8 3.4
16 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.7 3.4
18 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.6 3.3
20 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.5 3.3
21 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.5 3.3
23 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.4 3.2
25 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.3 3.2
27 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.3 3.1
29 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.2 3.1
31 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.1 3.0
33 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.0 3.0
35 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.0 2.9
37 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 4.9 2.9
39 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 4.8 2.8
10 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.4 4.2
12 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.3 4.2
14 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.2 4.1
16 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.1 4.1
18 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.0 4.0
20 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 6.9 4.0
21 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 6.8 3.9
23 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 6.7 3.9
25 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.6 4.2 6.6 3.8
27 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.4 4.1 6.6 3.8
29 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.4 4.1 6.5 3.7
31 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.3 4.0 6.4 3.7
33 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.2 3.9 6.3 3.6
35 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.0 3.9 6.2 3.5
37 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 5.8 4.0 5.9 3.8 6.1 3.5
39 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 5.7 3.9 5.8 3.7 6.0 3.4
4.5
Indoor unit
Ceiling Concealed Duct
- Built in
6-9 6-9
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
6.2 Heating Capacity
Notes:
TC: Total Capacity(kW)
Heating capacity
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 1.7 1.7 1.7 1.7 1.7 1.7
-18.8 -19.0 1.7 1.7 1.7 1.7 1.7 1.7
-16.7 -17.0 1.8 1.8 1.8 1.8 1.8 1.8
-14.7 -15.0 1.9 1.9 1.7 1.9 1.9 1.9
-12.6 -13.0 2.0 2.0 1.8 2.0 2.0 2.0
-10.5 -11.0 2.1 2.1 1.9 2.1 2.1 2.1
-9.5 -10.0 2.2 2.2 1.9 2.2 2.2 2.1
-8.5 -9.1 2.2 2.2 2.0 2.2 2.2 2.1
-7.0 -7.6 2.3 2.3 2.0 2.2 2.2 2.2
-5.0 -5.6 2.4 2.4 2.1 2.3 2.3 2.2
-3.0 -3.7 2.5 2.5 2.2 2.4 2.4 2.2
0.0 -0.7 2.6 2.6 2.3 2.4 2.4 2.2
3.0 2.2 2.8 2.7 2.4 2.4 2.4 2.2
5.0 4.1 2.8 2.7 2.5 2.4 2.4 2.2
7.0 6.0 2.9 2.7 2.5 2.4 2.4 2.2
9.0 7.9 2.9 2.7 2.5 2.4 2.4 2.2
11.0 9.8 2.9 2.7 2.5 2.4 2.4 2.2
13.0 11.8 2.9 2.7 2.5 2.4 2.4 2.2
15.0 13.7 2.9 2.7 2.5 2.4 2.4 2.2
-19.8 -20.0 2.1 2.1 2.1 2.1 2.1 2.1
-18.8 -19.0 2.2 2.2 2.2 2.2 2.2 2.2
-16.7 -17.0 2.3 2.3 2.3 2.3 2.3 2.3
-14.7 -15.0 2.5 2.4 2.2 2.4 2.4 2.4
-12.6 -13.0 2.6 2.6 2.3 2.6 2.6 2.6
-10.5 -11.0 2.7 2.7 2.4 2.7 2.7 2.7
-9.5 -10.0 2.8 2.8 2.5 2.8 2.8 2.7
-8.5 -9.1 2.8 2.8 2.5 2.8 2.8 2.7
-7.0 -7.6 2.9 2.9 2.6 2.8 2.8 2.8
-5.0 -5.6 3.0 3.0 2.7 3.0 3.0 2.8
-3.0 -3.7 3.2 3.2 2.8 3.1 3.0 2.8
0.0 -0.7 3.4 3.4 3.0 3.1 3.0 2.8
3.0 2.2 3.6 3.4 3.1 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.7 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.7 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.7 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.7 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.7 3.4 3.2 3.1 3.0 2.8
-19.8 -20.0 2.7 2.7 2.7 2.6 2.6 2.6
-18.8 -19.0 2.8 2.8 2.8 2.8 2.7 2.7
-16.7 -17.0 2.9 2.9 2.9 2.9 2.9 2.9
-14.7 -15.0 3.1 3.0 2.7 3.0 3.0 3.0
-12.6 -13.0 3.2 3.2 2.9 3.2 3.2 3.2
-10.5 -11.0 3.4 3.4 3.0 3.4 3.4 3.4
-9.5 -10.0 3.4 3.4 3.1 3.4 3.4 3.4
-8.5 -9.1 3.5 3.5 3.2 3.5 3.5 3.4
-7.0 -7.6 3.6 3.6 3.3 3.6 3.6 3.5
-5.0 -5.6 3.8 3.8 3.4 3.7 3.7 3.5
-3.0 -3.7 4.0 4.0 3.5 3.9 3.8 3.5
0.0 -0.7 4.2 4.2 3.7 3.9 3.8 3.5
3.0 2.2 4.4 4.3 3.9 3.9 3.8 3.5
5.0 4.1 4.5 4.3 4.0 3.9 3.8 3.5
7.0 6.0 4.6 4.3 4.0 3.9 3.8 3.5
9.0 7.9 4.6 4.3 4.0 3.9 3.8 3.5
11.0 9.8 4.6 4.3 4.0 3.9 3.8 3.5
13.0 11.8 4.6 4.3 4.0 3.9 3.8 3.5
15.0 13.7 4.6 4.3 4.0 3.9 3.8 3.5
2.2
2.8
3.6
Indoor unit
Ceiling Concealed Duct
- Built in
6-10 6-10
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
Notes:
TC: Total Capacity(kW)
Heating capacity
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 3.4 3.4 3.4 3.3 3.3 3.3
-18.8 -19.0 3.5 3.5 3.5 3.5 3.4 3.4
-16.7 -17.0 3.7 3.7 3.7 3.7 3.7 3.6
-14.7 -15.0 3.9 3.8 3.4 3.8 3.8 3.8
-12.6 -13.0 4.1 4.1 3.6 4.0 4.0 4.0
-10.5 -11.0 4.3 4.3 3.8 4.3 4.2 4.2
-9.5 -10.0 4.3 4.3 3.9 4.3 4.3 4.3
-8.5 -9.1 4.4 4.4 4.0 4.4 4.4 4.3
-7.0 -7.6 4.6 4.6 4.1 4.4 4.4 4.4
-5.0 -5.6 4.8 4.8 4.3 4.6 4.6 4.4
-3.0 -3.7 5.0 5.0 4.4 4.8 4.7 4.4
0.0 -0.7 5.3 5.3 4.6 4.8 4.7 4.4
3.0 2.2 5.6 5.4 4.9 4.8 4.7 4.4
5.0 4.1 5.6 5.4 5.0 4.8 4.7 4.4
7.0 6.0 5.8 5.4 5.0 4.8 4.7 4.4
9.0 7.9 5.8 5.4 5.0 4.8 4.7 4.4
11.0 9.8 5.8 5.4 5.0 4.8 4.7 4.4
13.0 11.8 5.8 5.4 5.0 4.8 4.7 4.4
15.0 13.7 5.8 5.4 5.0 4.8 4.7 4.4
-19.8 -20.0 4.2 4.2 4.2 4.2 4.2 4.2
-18.8 -19.0 4.3 4.3 4.3 4.3 4.3 4.3
-16.7 -17.0 4.6 4.6 4.6 4.6 4.6 4.5
-14.7 -15.0 4.9 4.8 4.3 4.8 4.8 4.8
-12.6 -13.0 5.1 5.1 4.5 5.0 5.0 5.0
-10.5 -11.0 5.4 5.4 4.8 5.4 5.3 5.3
-9.5 -10.0 5.4 5.4 4.9 5.4 5.4 5.4
-8.5 -9.1 5.5 5.5 5.0 5.5 5.5 5.4
-7.0 -7.6 5.7 5.7 5.1 5.6 5.6 5.5
-5.0 -5.6 6.0 6.0 5.4 5.8 5.8 5.5
-3.0 -3.7 6.2 6.2 5.5 6.1 5.9 5.5
0.0 -0.7 6.6 6.6 5.8 6.1 5.9 5.5
3.0 2.2 7.0 6.7 6.2 6.1 5.9 5.5
5.0 4.1 7.1 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.2 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.2 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.2 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.2 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.2 6.7 6.3 6.1 5.9 5.5
-19.8 -20.0 5.4 5.4 5.4 5.3 5.3 5.3
-18.8 -19.0 5.5 5.5 5.5 5.5 5.4 5.4
-16.7 -17.0 5.8 5.8 5.8 5.8 5.8 5.8
-14.7 -15.0 6.2 6.1 5.5 6.1 6.1 6.1
-12.6 -13.0 6.5 6.5 5.8 6.4 6.4 6.4
-10.5 -11.0 6.8 6.8 6.0 6.8 6.7 6.7
-9.5 -10.0 6.9 6.9 6.2 6.9 6.9 6.8
-8.5 -9.1 7.0 7.0 6.3 7.0 7.0 6.8
-7.0 -7.6 7.3 7.3 6.5 7.1 7.1 7.0
-5.0 -5.6 7.6 7.6 6.8 7.4 7.4 7.0
-3.0 -3.7 7.9 7.9 7.0 7.7 7.5 7.0
0.0 -0.7 8.4 8.4 7.4 7.8 7.5 7.0
3.0 2.2 8.9 8.6 7.8 7.8 7.5 7.0
5.0 4.1 9.0 8.6 8.0 7.8 7.5 7.0
7.0 6.0 9.2 8.6 8.0 7.8 7.5 7.0
9.0 7.9 9.2 8.6 8.0 7.8 7.5 7.0
11.0 9.8 9.2 8.6 8.0 7.8 7.5 7.0
13.0 11.8 9.2 8.6 8.0 7.8 7.5 7.0
15.0 13.7 9.2 8.6 8.0 7.8 7.5 7.0
4.5
5.6
7.1
Indoor unit
Ceiling Concealed Duct
- Built in
6-11 6-11
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
7. External Static Pressure (E.S.P) & Air Flow
Note :
1. The above table shows the correlation between the air rates and E.S.P.
2. E.S.P. is given after subtracting coil losses motor step factory installed
3. E.S.P. can be higher than the maximum given in the table, but the unit faces the problem of freezing the coil.
ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
Static Pressure(mmAq(Pa))
Setting Value
0(0) 1(10) 2(20) 3(29) 4(39)
60 6.29 3.03 0.93 - -
65 6.61 4.84 1.52 - -
70 7.69 5.64 2.18 0.79 -
75 8.19 6.28 2.81 0.85 -
80 8.91 7.43 4.96 1.58 -
85 9.51 8.14 5.91 2.75 0.95
90 10.21 8.76 6.79 3.41 1.36
95 10.83 9.62 8.11 5.48 2.61
100 11.31 10.55 9.02 6.12 3.31
105 11.84 11.19 9.99 8.28 5.32
110 12.68 11.88 10.38 9.16 6.92
115 13.19 12.22 11.55 10.21 8.23
Static Pressure(mmAq(Pa))
Setting Value
0(0) 1(10) 2(20) 3(29) 4(39)
75 10.32 7.68 3.55 - -
80 11.06 8.77 4.71 1.38 -
85 11.84 10.02 6.95 2.16 -
90 12.73 10.74 8.26 4.73 1.25
95 13.47 12.13 9.93 6.74 2.73
100 14.16 13.25 10.51 8.41 3.65
105 15.29 14.11 12.31 9.83 6.21
110 16.09 14.77 13.49 10.39 8.32
115 16.91 15.88 14.48 12.77 9.92
120 17.81 16.88 15.15 13.98 10.85
125 18.55 17.84 16.12 15.13 12.97
130 19.01 18.55 17.33 16.28 14.59
(Unit: CMM)
(Unit: CMM)
Indoor unit
Ceiling Concealed Duct
- Built in
6-12 6-12
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
Capacity Mode Set value
7k
High
(factory set)
High
(factory set)
High
(factory set)
High
(factory set)
HI 94
Mid 88
Low 83
HI 74
Mid 62
Low 56
HI 99
Mid 89
Low 85
HI 82
Mid 66
Low 58
HI 105
Mid 94
Low 88
HI 90
Mid 74
Low 62
HI 110
Mid 105
Low 94
HI 96
Mid 90
Low 74
8
6.5
5.5
8
6.5
5.5
9
7
6
9
7
6
10
8
6.5
10
8
6.5
11
10
8
11
10
8
2(20)
0(0)
2(20)
0(0)
2(20)
0(0)
2(20)
0(0)
- 4(39)
- 4(39)
- 4(39)
- 4(39)
- 4(39)
- 4(39)
- 4(39)
- 4(39))
Standard
Standard
Standard
Standard
9k
12k
15k
Standard
ESP(mmAq(Pa))
CMM
Lower Limit of External
Static Pressure(mmAq(Pa))
Upper Limit of External
Static Pressure(mmAq(Pa))
ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
Capacity Mode Set value
18k
High
(factory set)
High
(factory set)
HI 115
Mid 103
Low 93
HI 100
Mid 86
Low 74
HI 128
Mid 118
Low 93
HI 116
Mid 104
Low 74
14
12
10
14
12
10
17
15
10
17
15
10
2(20)
0(0)
2(20)
0(0)
- 4(39)
- 4(39)
- 4(39)
- 4(39)
Standard
Standard
24k
Standard
ESP(mmAq(Pa))
CMM
Lower Limit of External
Static Pressure(mmAq(Pa))
Upper Limit of External
Static Pressure(mmAq(Pa))
Indoor unit
Ceiling Concealed Duct
- Built in
6-13 6-13
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
8. Electric Characteristics
Symbols:
MCA : Min, Circuit Amps(A)
MFA : Max. Fuse Amps(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amps(A)
IFA : Indoor Fan Motor
Note :
1. Voltage range
Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above
listed range limits,
2. Maximum allowable voltage unbalance between phases is 2%
3. MCA/MFA
MCA=1.25 x FLA
MFA 4 x FLA
(Next lower standard fuse rating. Min. 15A)
4. Select wire size based on the MCA
5. Instead of fuse, use Circuit Breaker.
Units
Model Type Hz Volts Voltage Range
ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) B3 0.22 15 0.028 0.17 30 30
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) B3 0.22 15 0.028 0.17 30 30
ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) B3
50 220-240
Max:264 0.22 15 0.028 0.17 30 30
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) B3 Min:198 0.22 15 0.028 0.17 30 30
ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y) B4 0.55 15 0.076 0.44 80 80
ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y) B4 0.55 15 0.076 0.44 80 80
ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) B3 0.22 15 0.028 0.17 30 30
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) B3 0.22 15 0.028 0.17 30 30
ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) B3
60 220
Max:242 0.22 15 0.028 0.17 30 30
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) B3 Min:198 0.22 15 0.028 0.17 30 30
ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y) B4 0.55 15 0.076 0.44 80 80
ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y) B4 0.55 15 0.076 0.44 80 80
Power Supply IFM Input(W)
MCA MFA kW FLA Cooling Heating
Indoor unit
Ceiling Concealed Duct
- Built in
6-14 6-14
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
9. Sound Levels
Overall
Sound Pressure Level
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l
(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l
(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l
(
d
B

r
e

2
0

P
a

)
Notes:
- Sound measured at 1.5m away from the center of the unit.
- Data is valid at free field condition
- Data is valid at nominal operation condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.
Model Name
ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
Sound Levels dB(A)
H M L
33
34
35
41
43
46
32
33
34
40
40
43
29
32
33
37
37
37
1
.
5
m
Ceiling
2.0m
Microphone
ARNU07GB3G2+
PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU15GB3G2+
PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU09GB3G2+
PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU12GB3G2+
PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU18GB4G2+
PBSGB40(Acc'y), PBSC40(Acc'y)
ARNU24GB4G2+
PBSGB40(Acc'y), PBSC40(Acc'y)
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold 10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l
(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l
(
d
B

r
e

2
0

P
a

)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l
(
d
B

r
e

2
0

P
a

)
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
Indoor unit
Ceiling Concealed Duct
- Built in
6-15 6-15
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
10. Installation
Please read this instruction sheet completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
Suction Grille
Suction Grille +
Suction Canvas
Remote Controller
TEMP
Remote Controller
TEMP
Required Parts Required Tools
Connecting cable
Pipes: Gas side
Liquid side
Hanging Bolt
(W 3/8 or M10 length 650mm)
Insulated drain hose
Additional Drain hose
(Inner Dia ....................................25mm)
Level
Screw driver
Electric drill
Hole core drill (70mm)
Flaring Tools set
Torque Wrenches
Hexagonal Wrench (4mm, 5mm)
Gas-leak detector
Owners Manual
Thermometer
Indoor unit
Ceiling Concealed Duct
- Built in
6-16 6-16
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
Refer to Suction grille and Suction canvas installation
manual for detail installation of Built-in duct type
2
7
0

o
r

m
o
r
e
5
2
0

o
r

m
o
r
e
Inspection hole
(600 x 600)
Control box
600 600
Top view
(unit:mm)
Airflow
10.1 Selection of the best location
Install the air conditioner in the location that satisfies the
following conditions.
The place shall easily bear a load exceeding four times
the indoor units weight.
The place shall be able to inspect the unit as the figure.
The place where the unit shall be leveled.
The place shall easily connect with the outdoor unit.
The place where the unit is not affected by an electrical
noise.
The place where air circulation in the room will be good .
There should not be any heat source or steam near the
unit
Confirm the positional relationship between the unit and
suspension bolts.
Installation the ceiling opening to clean the filter or ser-
vice under the product.
Chassis A B
B3 600 900
B4 600 1100
(Unit : mm)
B3/B4 Series : Built-in Duct type
A(Min)
B(Min)
Ceiling
Service Space
A
B
Indoor unit
Ceiling Concealed Duct
- Built in
6-17 6-17
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
Installation of Unit
Install the unit above the ceiling correctly.
Apply a joint-canvas between the unit and duct to absorb
unnecessary vibration.
Apply a filter Accessory at air return hole.
Install the unit leaning to a drainage hole side as a figure
for easy water drainage.
A place where the unit will be leveled and that can support
the weight of the unit.
A place where the unit can withstand its vibration.
A place where service can be easily performed.
CASE 1
POSITION OF SUSPENSION BOLT
C
E
G
D
A
J
B
M10 Nut
M10 washer
X 4
X 4
M10 Nut
M10 washer X 4
X 8
I
F
H
Drainage hole
Drain Pump use
CASE 2
POSITION OF CONSOLE BOLT
10.2 Ceiling dimension and hanging bolt location
(Unit:mm)
B3 850 900 383 575 93 190 21 795 163 820
B4 1130 1180 383 575 93 190 21 1065 163 1100
Dimension
Chassis
A B C D E F G H I J
Indoor unit
Ceiling Concealed Duct
- Built in
6-18 6-18
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
Select and mark the position for fixing bolts.
Drill the hole for set anchor on the face of ceiling.
Insert the set anchor and washer onto the suspen-
sion bolts for locking the suspension bolts on the
ceiling.
Mount the suspension bolts to the set anchor firmly.
Secure the installation plates onto the suspension
bolts (adjust level roughly) using nuts, washers and
spring washers.
Tighten the nut and bolt to prevent unit falling.
CAUTION
1 Set anchor
Old building New building
2 Plate washer
3 Spring washer
4 Nut
5 Suspension
bolts
10.3 Connecting Cables
Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively
Clamping of cables
1) Arrange 2 power cables on the control panel.
2) First, fasten the steel clamp with a screw to the inner boss of control panel.
3) For the cooling model, fix the other side of the clamp with a screw strongly. For the heat pump model, put the
0.75mm
2
cable(thinner cable) on the clamp and tighten it with a plastic clamp to the other boss of the control
panel.
Make sure that the screws of the terminal are not from loose.
WARNING
Terminal Block Indoor
1(L) 2(N) 3 4
INDOOR POWER INPUT
A - - - - - - B A B
GND 12V DRY2 DRY1 INTERNET IDU SODU Outdoor
Unit
Indoor unit
Ceiling Concealed Duct
- Built in
6-19 6-19
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
Buit-in duct type with Suction Grille Buit-in duct type with Suction Grille and Suction
Canvas
Suction Grille
Suction Grille
Suction Canvas
Air outlet
Air outlet
10.4 Part name and functions
I B3/B4 Series : Built-in Duct type Control Box service
Indoor unit
Ceiling Concealed Duct
- Built in
6-20 6-20
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
1. Remove the Air Filter. 2. Check the drainage.
Spray one or two glasses of water upon the
evaporator.
Ensure that water flows drain hose of indoor unit
without any leakage.
INSULATION, OTHERS Insulate the joint and tubes completely.
All thermal insulation must comply with local requirement.
INDOOR UNIT
I After all workings are finished, check the working and operation.
Air distribution ............... Is the air circulation good?
Drain ............................. Is the drainage smoothly and no sweating?
Gas leakage ................. Is the piping connection correctly?
Wiring ........................... Is the wiring connection correctly?
Lock-bolt ....................... Is the lock-bolt of compressor loosened?
Insulation Is the unit fully insulated?
Ground Is the unit safely grounded?
THERMAL INSULATION
TEST AND CHECK
Make sure that there is no clearance here.
Overlap with thermal
insulator for piping.
Thermal insulator for refrigerant pipe
(Local supply)
Thermal insulator for
piping(Local supply)
Hose clip for thermal insulator(Local supply)
Felt
Rubber
Insulation
No clearance
Cabinet
Refrigerant pipe and thermal
insulator(Local supply)
Thermal insulator for refrigerant pipe
(Local supply)
Hose clip for thermal insulator
(Local supply)
Union for liquid pipe
Union for gas pipe
10.5 Checking the Drainage
Indoor unit
Ceiling Concealed Duct
- Built in
6-21 6-21
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
CAUTION
Ceiling
Drain Pump use
Drainage hole
Front of view
1. Install declination of the indoor unit is very important for the drain of the duct type air conditioner.
2. Minimum thickness of the insulation for the connecting pipe shall be 19mm.
The unit must be horizontal or declined to the drain hose connected when finished
installation.
Drain piping must have down-slope (1/50 to 1/100): be sure not to
provide up-and-down slope to prevent reversal flow.
During drain piping connection, be careful not to exert extra force
on the drain port on the indoor unit.
The outside diameter of the drain connection on the indoor unit is
32mm.
Be sure to install heat insulation on the drain piping.
Piping material: Polyvinyl chloride pipe VP-25 and
pipe fittings
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:
Connect the main drain pipe to the exterior and
leave it provisionally until the test comes to an
end.
Feed water to the flexible drain hose and check
the piping for leakage.
Be sure to check the drain pump for normal oper-
ating and noise when electrical wiring is complete.
When the test is complete, connect the flexible
drain hose to the drain port on the indoor unit.
Heat insulation material: Polyethylene foam with thick-
ness more than 8 mm.
Drain test
Feed water
Drain Pump
Drain pan
Flexible drain hose
Main
drain pipe
Glue the joint
Drain
port
Drain hose connection
Use the clip
Upward
routing
not allowed
Pipe clamp
1/50~1/100
MAX 700mm
Maintenance
drain port
Indoor unit
10.6 Drain Piping
Indoor unit
Ceiling Concealed Duct
- Built in
6-22 6-22
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
CAUTION:
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have an individual power specialized for the air conditioner. As for the method of
wiring, be guided by the circuit diagram posted on the inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screws which fasten the wiring in the casing of electrical fittings are liable to come loose
from vibrations to which the unit is subjected during the course of transportation. Check them
and make sure that they are all tightly fastened. (If they are loose, it could give rise to burn-out
of the wires.)
4) Specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage
marked on the name plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Never fail to equip a leakage breaker where it is wet or moist.
9) The following troubles would be caused by voltage drop-down.
Vibration of a magnetic switch, damage on the contact point, fuse breaking, disturbance by the nor-
mal function of an overload protection device.
Proper starting power is not given to the compressor.
HAND OVER
Teach the customer the operation and maintenance procedures, using the operation manual.
(air filter cleaning, temperature control, etc.)
1/50~1/100 slope
Hanger
distance
Hanger Bracket
M
a
x

7
0
0
m
m
Flexible drain hose
Insulation
Metal
clamp
Max 300mm
1~15m
CAUTION : The supplied flexible drain
hose should not be curved, neither
screwed. The curved or screwed hose
may cause a leakage of water.
Indoor unit
Ceiling Concealed Duct
- Built in
6-23 6-23
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
WIRED REMOTE CONTROLLER INSTALLATION
Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average tempera-
ture.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
Fig.1 Typical locations for remote controller
5feet
(1.5meters)
no
no
no
yes
Remote Controller
TEMP
Remote Controller
TEMP
Remote Controller
TEMP
Indoor unit
Ceiling Concealed Duct
- Built in
6-24 6-24
C
e
i
l
i
n
g

C
o
n
c
e
a
l
e
d

D
u
c
t
-

B
u
i
l
t

i
n
11. Accessories
Name
Quantity
Shape
for gas pipe
for liquid pipe
Clamp metal
2 EA
Insulation for
fitting
1 SET
Drain hose
1 EA
Clamp
(Tie Wrap)
8 EA
Washer for
hanging backet
4 EA
(Other)
Standard Accessories
Owner's manual
Installation manual
Use only those accessories (Standard or optional) which have designated specilications.
CAUTION
Indoor unit
Wall Mounted
W
a
l
l

M
o
u
n
t
e
d
1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. Air Velocity and Temperature Distribution
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories
Wall Mounted
Indoor unit
Wall Mounted
7-1 7-1
W
a
l
l

M
o
u
n
t
e
d
1. List of functions
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Air flow
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Air purifying Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
Installation
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Reliability Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Convenience Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Individual Simple wired remote controller
control Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Special
Zone control
function kit
CTIE
Electro thermostat
1
SE Manual / S5 Auto
Auto
SE Manual / S5 Auto
X
3 / 4 / 3
O
O
O
-
X
Option
O
-
-
-
-
O
O
O
O(Heat recovery)
O
O(Heat pump or Cooling only)
O
O
O
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
Accessory
Accessory
-
-
-
Function Category
ARNU07GSE*2, ARNU09GSE*2, ARNU12GSE*2
ARNU15GSE*2, ARNU18GS5*2, ARNU24GS5*2
O : Applied X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.
Indoor unit
Wall Mounted
7-2 7-2
W
a
l
l

M
o
u
n
t
e
d
2. Specifications
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Fan Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Color
Wall Mounted
ARNU07GSE*2 ARNU09GSE*2 ARNU12GSE*2
2.2 2.8 3.6
1,900 2,400 3,100
7,500 9,600 12,300
2.5 3.2 4.0
2,200 2,800 3,400
8,500 10,900 13,600
895 x 165 x 282 895 x 165 x 282 895 x 165 x 282
35.2 x 6.5 x 11.1 35.2 x 6.5 x 11.1 35.2 x 6.5 x 11.1
2 x 15 x 18 2 x 15 x 18 2 x 15 x 18
0.21 0.21 0.21
Cross Flow Fan Cross Flow Fan Cross Flow Fan
20 20 20
0.2 0.2 0.2
5.6 / 5.0 / 4.6 7.0 / 6.5 / 6.0 9.5 / 9.0 / 8.5
198.0 / 177.0 / 162.5 247.0 / 230.0 / 212.0 336.0 / 318.0 / 300.0
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene
Resin Net(washable) Resin Net(washable) Resin Net(washable)
Fuse Fuse Fuse
6.35(1/4) 6.35(1/4) 6.35(1/4)
12.7(1/2) 12.7(1/2) 12.7(1/2)
16(5/8) 16(5/8) 16(5/8)
9(19.8) 9(19.8) 9(19.8)
37 / 33 / 23 39 / 35 / 25 41 / 36 / 27
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Morning fog Morning fog Morning fog
* Model Name
A:Basic L:Plasma
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Indoor unit
Wall Mounted
7-3 7-3
W
a
l
l

M
o
u
n
t
e
d
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Fan Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Color
Wall Mounted
ARNU15GSE*2 ARNU18GS5*2 ARNU24GS5*2
4.5 5.6 7.1
3,900 4,800 6,100
15,400 19,100 24,200
5.0 6.3 8.0
4,300 5,400 6,900
17,100 21,500 27,300
895 x 165 x 282 1,090 x 178 x 300 1,090 x 178 x 300
35.2 x 6.5 x 11.1 42.9 x 7 x 11.8 42.9 x 7 x 11.8
2 x 15 x 18 2 x 15 x 20 2 x 15 x 20
0.21 0.26 0.26
Cross Flow Fan Cross Flow Fan Cross Flow Fan
20 20 20
0.2 0.2 0.2
10.5 / 9.0 / 8.5 12.0 / 10.5 / 9.0 14.0 / 13.0 / 10.0
371.0 / 318.0 / 300.0 424.0 / 371.0 / 318.0 494.0 / 459.0 / 353.0
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene
Resin Net(washable) Resin Net(washable) Resin Net(washable)
Fuse Fuse Fuse
6.35(1/4) 6.35(1/4) 9.52(3/8)
12.7(1/2) 12.7(1/2) 15.88(5/8)
16(5/8) 16(5/8) 16(5/8)
9(19.8) 12(26.5) 12(26.5)
42 / 36 / 27 44 / 40 / 36 46 / 41 / 38
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Morning fog Morning fog Morning fog
* Model Name
A:Basic L:Plasma
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Indoor unit
Wall Mounted
7-4 7-4
W
a
l
l

M
o
u
n
t
e
d
3. Dimensions
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

S
E
W
a
l
l

M
o
u
n
t
e
d
A
R
N
U
0
7
G
S
E
*
2
A
R
N
U
0
9
G
S
E
*
2
A
R
N
U
1
2
G
S
E
*
2
A
R
N
U
1
5
G
S
E
*
2
W
M
o
d
e
l
A
R
N
U
0
7
G
S
E
*
2
A
R
N
U
0
9
G
S
E
*
2
A
R
N
U
1
2
G
S
E
*
2
A
R
N
U
1
5
G
S
E
*
2
H
D
8
9
5

2
8
2
1
6
5
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
(
u
n
i
t

:

m
m
)
1 6 5
8
9
5
2 8 2
5
6
7
2 6 5
2
1
N
a
m
e



1
A
i
r

d
i
s
c
h
a
r
g
e

g
r
i
l
l




2
A
i
r

s
u
c
t
i
o
n

g
r
i
l
l

N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
(
u
n
i
t

:

m
m
)
Indoor unit
Wall Mounted
7-5 7-5
W
a
l
l

M
o
u
n
t
e
d
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

S
5
W
a
l
l

M
o
u
n
t
e
d
A
R
N
U
1
8
G
S
5
*
2
A
R
N
U
2
4
G
S
5
*
2
W
M
o
d
e
l
A
R
N
U
1
8
G
S
5
*
2
A
R
N
U
2
4
G
S
5
*
2
H
D
1
0
9
0

3
0
0
1
7
8
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
(
u
n
i
t

:

m
m
)
1
,
0
9
0
1
7
8
3 0 0
2 8 1
8
0
4
N
a
m
e



1
A
i
r

d
i
s
c
h
a
r
g
e

g
r
i
l
l




2
A
i
r

s
u
c
t
i
o
n

g
r
i
l
l

N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
(
u
n
i
t

:

m
m
)
1
2
Indoor unit
Wall Mounted
7-6 7-6
W
a
l
l

M
o
u
n
t
e
d
4. Piping Diagrams
Heat Exchanger
C.F.F
lndoor unit
EEV
:Heating
:Cooling
Filter
Filter
Th3 Th2
Th1
Refrigerant pipe connection port diameter
MODEL GAS LIQUID
ARNU07GSE*2 12.7(1/2) 6.35(1/4)
ARNU09GSE*2 12.7(1/2) 6.35(1/4)
ARNU12GSE*2 12.7(1/2) 6.35(1/4)
ARNU15GSE*2 12.7(1/2) 6.35(1/4)
ARNU18GS5*2 12.7(1/2) 6.35(1/4)
ARNU24GS5*2 15.88(5/8) 9.52(3/8)
[Unit: mm(inch)]
LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor
Indoor unit
Wall Mounted
7-7 7-7
W
a
l
l

M
o
u
n
t
e
d
5. Wiring Diagrams
CONNECTOR NUMBER LOCATION POINT FUNCTION
CN-POWER AC Power supply AC Power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-COM Communication Connection between indoor and outdoor
CN-DISP1 Display Display of indoor status
CN-DISP2 Display Display of indoor status
CN-EEV EEV output EEV control output
CN-U/D, CN-L/R Step motor Step motor output
CN-TH1 Room/pipe sensor Room and pipe thermistor
CN-REMO Remote controller Remote control line
CN-CC Dry contact Dry contact line
CN-HVB Air clean Air clean control
SE Chassis
S5 Chassis
Indoor unit
Wall Mounted
7-8 7-8
W
a
l
l

M
o
u
n
t
e
d
6. Capacity Tables
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
6.1 Cooling Capacity
Cooling Capacity
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.7 2.8
12 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.7 2.7
14 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.6 2.7
16 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.6 2.7
18 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.5 2.6
20 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.4 2.6
21 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.4 2.6
23 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.3 2.5
25 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.2 2.8 4.3 2.5
27 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.7 4.2 2.5
29 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.7 4.2 2.4
31 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.6 4.1 2.4
33 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.6 4.0 2.4
35 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 3.9 2.5 4.0 2.3
37 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.8 2.5 3.9 2.3
39 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.7 2.4 3.8 2.2
2.8
3.6
10 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.9 1.7
12 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.9 1.6
14 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.8 1.6
16 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.8 1.6
18 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.6
20 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.6
21 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.5
23 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.6 1.5
25 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.6 1.5
27 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.6 1.5
29 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.5 1.5
31 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.5 1.4
33 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.4 1.5 2.5 1.4
35 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.4 1.5 2.4 1.4
37 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.3 1.5 2.4 1.4
39 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.2 1.5 2.3 1.5 2.3 1.4
10 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.7 2.1
12 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.6 2.1
14 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.6 2.1
16 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.5 2.0
18 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.5 2.0
20 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 2.0
21 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 2.0
23 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 1.9
25 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.3 2.1 3.3 1.9
27 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 2.1 3.3 1.9
29 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 2.0 3.2 1.9
31 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.1 2.0 3.2 1.8
33 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.1 2.0 3.1 1.8
35 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.0 1.9 3.1 1.8
37 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 3.0 1.9 3.0 1.8
39 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 2.9 1.9 3.0 1.7
2.2
Indoor unit
Wall Mounted
7-9 7-9
W
a
l
l

M
o
u
n
t
e
d
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
Cooling Capacity
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.3 5.4
12 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.2 5.4
14 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.1 5.3
16 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.0 5.2
18 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.8 5.2
20 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.7 5.1
21 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.7 5.1
23 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.5 5.0
25 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.4 5.4 8.4 4.9
27 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.2 5.3 8.3 4.9
29 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.1 5.2 8.2 4.8
31 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.0 5.1 8.1 4.7
33 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 7.8 5.1 7.9 4.6
35 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 7.7 5.0 7.8 4.6
37 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.4 5.1 7.5 4.9 7.7 4.5
39 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.2 5.0 7.4 4.8 7.6 4.4
5.6
7.1
10 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.9 3.5
12 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.8 3.4
14 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.8 3.4
16 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.7 3.3
18 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.6 3.3
20 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.5 3.2
21 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.5 3.2
23 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.4 3.2
25 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.3 3.1
27 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.3 3.1
29 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.2 3.0
31 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.1 3.0
33 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.0 2.9
35 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.0 2.9
37 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 4.9 2.9
39 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 4.8 2.8
10 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.4 4.3
12 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.3 4.2
14 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.2 4.2
16 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.1 4.1
18 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.0 4.1
20 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.9 4.0
21 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.8 4.0
23 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.7 3.9
25 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.6 4.3 6.6 3.9
27 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.4 4.2 6.6 3.8
29 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.4 4.1 6.5 3.8
31 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.3 4.1 6.4 3.7
33 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.2 4.0 6.3 3.7
35 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.0 3.9 6.2 3.6
37 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 5.8 4.1 5.9 3.8 6.1 3.6
39 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 5.7 4.0 5.8 3.8 6.0 3.5
4.5
Indoor unit
Wall Mounted
7-10 7-10
W
a
l
l

M
o
u
n
t
e
d
6.2 Heating Capacity
Notes: TC: Total Capacity(kW)
Heating Capacity
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 1.7 1.7 1.7 1.7 1.7 1.7
-18.8 -19.0 1.7 1.7 1.7 1.7 1.7 1.7
-16.7 -17.0 1.8 1.8 1.8 1.8 1.8 1.8
-14.7 -15.0 1.9 1.9 1.7 1.9 1.9 1.9
-12.6 -13.0 2.0 2.0 1.8 2.0 2.0 2.0
-10.5 -11.0 2.1 2.1 1.9 2.1 2.1 2.1
-9.5 -10.0 2.2 2.2 1.9 2.2 2.2 2.1
-8.5 -9.1 2.2 2.2 2.0 2.2 2.2 2.1
-7.0 -7.6 2.3 2.3 2.0 2.2 2.2 2.2
-5.0 -5.6 2.4 2.4 2.1 2.3 2.3 2.2
-3.0 -3.7 2.5 2.5 2.2 2.4 2.4 2.2
0.0 -0.7 2.6 2.6 2.3 2.4 2.4 2.2
3.0 2.2 2.8 2.7 2.4 2.4 2.4 2.2
5.0 4.1 2.8 2.7 2.5 2.4 2.4 2.2
7.0 6.0 2.9 2.7 2.5 2.4 2.4 2.2
9.0 7.9 2.9 2.7 2.5 2.4 2.4 2.2
11.0 9.8 2.9 2.7 2.5 2.4 2.4 2.2
13.0 11.8 2.9 2.7 2.5 2.4 2.4 2.2
15.0 13.7 2.9 2.7 2.5 2.4 2.4 2.2
-19.8 -20.0 2.1 2.1 2.1 2.1 2.1 2.1
-18.8 -19.0 2.2 2.2 2.2 2.2 2.2 2.2
-16.7 -17.0 2.3 2.3 2.3 2.3 2.3 2.3
-14.7 -15.0 2.5 2.4 2.2 2.4 2.4 2.4
-12.6 -13.0 2.6 2.6 2.3 2.6 2.6 2.6
-10.5 -11.0 2.7 2.7 2.4 2.7 2.7 2.7
-9.5 -10.0 2.8 2.8 2.5 2.8 2.8 2.7
-8.5 -9.1 2.8 2.8 2.5 2.8 2.8 2.7
-7.0 -7.6 2.9 2.9 2.6 2.8 2.8 2.8
-5.0 -5.6 3.0 3.0 2.7 3.0 3.0 2.8
-3.0 -3.7 3.2 3.2 2.8 3.1 3.0 2.8
0.0 -0.7 3.4 3.4 3.0 3.1 3.0 2.8
3.0 2.2 3.6 3.4 3.1 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.7 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.7 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.7 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.7 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.7 3.4 3.2 3.1 3.0 2.8
-19.8 -20.0 2.7 2.7 2.7 2.6 2.6 2.6
-18.8 -19.0 2.8 2.8 2.8 2.8 2.7 2.7
-16.7 -17.0 2.9 2.9 2.9 2.9 2.9 2.9
-14.7 -15.0 3.1 3.0 2.7 3.0 3.0 3.0
-12.6 -13.0 3.2 3.2 2.9 3.2 3.2 3.2
-10.5 -11.0 3.4 3.4 3.0 3.4 3.4 3.4
-9.5 -10.0 3.4 3.4 3.1 3.4 3.4 3.4
-8.5 -9.1 3.5 3.5 3.2 3.5 3.5 3.4
-7.0 -7.6 3.6 3.6 3.3 3.6 3.6 3.5
-5.0 -5.6 3.8 3.8 3.4 3.7 3.7 3.5
-3.0 -3.7 4.0 4.0 3.5 3.9 3.8 3.5
0.0 -0.7 4.2 4.2 3.7 3.9 3.8 3.5
3.0 2.2 4.4 4.3 3.9 3.9 3.8 3.5
5.0 4.1 4.5 4.3 4.0 3.9 3.8 3.5
7.0 6.0 4.6 4.3 4.0 3.9 3.8 3.5
9.0 7.9 4.6 4.3 4.0 3.9 3.8 3.5
11.0 9.8 4.6 4.3 4.0 3.9 3.8 3.5
13.0 11.8 4.6 4.3 4.0 3.9 3.8 3.5
15.0 13.7 4.6 4.3 4.0 3.9 3.8 3.5
2.2
2.8
3.6
Indoor unit
Wall Mounted
7-11 7-11
W
a
l
l

M
o
u
n
t
e
d
Notes: TC: Total Capacity(kW)
Heating Capacity
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 3.4 3.4 3.4 3.3 3.3 3.3
-18.8 -19.0 3.5 3.5 3.5 3.5 3.4 3.4
-16.7 -17.0 3.7 3.7 3.7 3.7 3.7 3.6
-14.7 -15.0 3.9 3.8 3.4 3.8 3.8 3.8
-12.6 -13.0 4.1 4.1 3.6 4.0 4.0 4.0
-10.5 -11.0 4.3 4.3 3.8 4.3 4.2 4.2
-9.5 -10.0 4.3 4.3 3.9 4.3 4.3 4.3
-8.5 -9.1 4.4 4.4 4.0 4.4 4.4 4.3
-7.0 -7.6 4.6 4.6 4.1 4.4 4.4 4.4
-5.0 -5.6 4.8 4.8 4.3 4.6 4.6 4.4
-3.0 -3.7 5.0 5.0 4.4 4.8 4.7 4.4
0.0 -0.7 5.3 5.3 4.6 4.8 4.7 4.4
3.0 2.2 5.6 5.4 4.9 4.8 4.7 4.4
5.0 4.1 5.6 5.4 5.0 4.8 4.7 4.4
7.0 6.0 5.8 5.4 5.0 4.8 4.7 4.4
9.0 7.9 5.8 5.4 5.0 4.8 4.7 4.4
11.0 9.8 5.8 5.4 5.0 4.8 4.7 4.4
13.0 11.8 5.8 5.4 5.0 4.8 4.7 4.4
15.0 13.7 5.8 5.4 5.0 4.8 4.7 4.4
-19.8 -20.0 4.2 4.2 4.2 4.2 4.2 4.2
-18.8 -19.0 4.3 4.3 4.3 4.3 4.3 4.3
-16.7 -17.0 4.6 4.6 4.6 4.6 4.6 4.5
-14.7 -15.0 4.9 4.8 4.3 4.8 4.8 4.8
-12.6 -13.0 5.1 5.1 4.5 5.0 5.0 5.0
-10.5 -11.0 5.4 5.4 4.8 5.4 5.3 5.3
-9.5 -10.0 5.4 5.4 4.9 5.4 5.4 5.4
-8.5 -9.1 5.5 5.5 5.0 5.5 5.5 5.4
-7.0 -7.6 5.7 5.7 5.1 5.6 5.6 5.5
-5.0 -5.6 6.0 6.0 5.4 5.8 5.8 5.5
-3.0 -3.7 6.2 6.2 5.5 6.1 5.9 5.5
0.0 -0.7 6.6 6.6 5.8 6.1 5.9 5.5
3.0 2.2 7.0 6.7 6.2 6.1 5.9 5.5
5.0 4.1 7.1 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.2 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.2 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.2 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.2 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.2 6.7 6.3 6.1 5.9 5.5
-19.8 -20.0 5.4 5.4 5.4 5.3 5.3 5.3
-18.8 -19.0 5.5 5.5 5.5 5.5 5.4 5.4
-16.7 -17.0 5.8 5.8 5.8 5.8 5.8 5.8
-14.7 -15.0 6.2 6.1 5.5 6.1 6.1 6.1
-12.6 -13.0 6.5 6.5 5.8 6.4 6.4 6.4
-10.5 -11.0 6.8 6.8 6.0 6.8 6.7 6.7
-9.5 -10.0 6.9 6.9 6.2 6.9 6.9 6.8
-8.5 -9.1 7.0 7.0 6.3 7.0 7.0 6.8
-7.0 -7.6 7.3 7.3 6.5 7.1 7.1 7.0
-5.0 -5.6 7.6 7.6 6.8 7.4 7.4 7.0
-3.0 -3.7 7.9 7.9 7.0 7.7 7.5 7.0
0.0 -0.7 8.4 8.4 7.4 7.8 7.5 7.0
3.0 2.2 8.9 8.6 7.8 7.8 7.5 7.0
5.0 4.1 9.0 8.6 8.0 7.8 7.5 7.0
7.0 6.0 9.2 8.6 8.0 7.8 7.5 7.0
9.0 7.9 9.2 8.6 8.0 7.8 7.5 7.0
11.0 9.8 9.2 8.6 8.0 7.8 7.5 7.0
13.0 11.8 9.2 8.6 8.0 7.8 7.5 7.0
15.0 13.7 9.2 8.6 8.0 7.8 7.5 7.0
4.5
5.6
7.1
Indoor unit
Wall Mounted
7-12 7-12
W
a
l
l

M
o
u
n
t
e
d
7. Air Velocity and Temperature Distribution(Reference Data)
ARNU07GSE*2
22
20
24
18
1.0
1.5
0.5
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
22
20
24
18
1.0
1.5
0.5
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
21 24
27
30
33
1.0
2.0
1.5
0.5
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
1.0
2.0
1.5
0.5
21
24
27
30
33
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
Cooling
Discharge angle:45
Heating
Discharge angle:50
Cooling
Discharge angle:45
Heating
Discharge angle:50
ARNU09GSE*2
Indoor unit
Wall Mounted
7-13 7-13
W
a
l
l

M
o
u
n
t
e
d
ARNU12GSE*2
ARNU18GS5*2
22
20
24
18
Air velocity [m/s]
Temperature [C]
1.0
2.0
1.5
0.5
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
1.0
2.0
1.5
0.5
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
21
24
27
30
33
Cooling
Discharge angle:45
Heating
Discharge angle:50
18
20
22
24
1.0 0.5
2.5
1.5
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
8m 7m 6m 5m 4m 3m 2m 1m 0m
2.7m
2m
1m
0m
8m 7m 6m 5m 4m 3m 2m 1m 0m
1.0
2.0
1.5
0.5
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
8m 7m 6m 5m 4m 3m 2m 1m 0m
2.7m
2m
1m
0m
8m 7m 6m 5m 4m 3m 2m 1m 0m
33
30
27
24
21
Cooling
Discharge angle:45
Heating
Discharge angle:50
Indoor unit
Wall Mounted
7-14 7-14
W
a
l
l

M
o
u
n
t
e
d
8. Electric Characteristics
Symbols:
MCA :Min, Circuit Amps(A)
MFA:Max. Fuse Amps(see note 5)
kW:Fan Motor Rated Output(kW)
FLA:Full Load Amps(A)
IFM:Indoor Fan Motor
Note :
1. Voltage range
Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above
the listed range limits.
2. Maximum allowable voltage unbalance between phases is 2%
3. MCA/MFA
MCA=1.25 x FLA
MFA 4 x FLA
(Next lower standard fuse rating. Min. 15A)
4. Select wire size based on the MCA
5. Instead of fuse, use Circuit Breaker.
Units
Model Type Hz Volts Voltage Range
ARNU07GSE*2 SE 0.29 15 0.02 0.23 40 40
ARNU09GSE*2 SE 0.29 15 0.02 0.23 40 40
ARNU12GSE*2 SE
50 220 - 240
Max:264 0.29 15 0.02 0.23 40 40
ARNU15GSE*2 SE Min:198 0.29 15 0.02 0.23 40 40
ARNU18GS5*2 S5 0.29 15 0.02 0.23 40 40
ARNU24GS5*2 S5 0.29 15 0.02 0.23 40 40
ARNU07GSE*2 SE 0.29 15 0.02 0.23 40 40
ARNU09GSE*2 SE 0.29 15 0.02 0.23 40 40
ARNU12GSE*2 SE
60 220
Max:242 0.29 15 0.02 0.23 40 40
ARNU15GSE*2 SE Min:198 0.29 15 0.02 0.23 40 40
ARNU18GS5*2 S5 0.29 15 0.02 0.23 40 40
ARNU24GS5*2 S5 0.29 15 0.02 0.23 40 40
Power Supply IFM Input(W)
MCA MFA kW FLA Cooling Heating
Indoor unit
Wall Mounted
7-15 7-15
W
a
l
l

M
o
u
n
t
e
d
9. Sound Levels
Overall
Sound Pressure Level
Model
ARNU07GSE*2
ARNU09GSE*2
ARNU12GSE*2
ARNU15GSE*2
ARNU18GS5*2
ARNU24GS5*2
Sound Levels dB(A)
H M L
37
39
41
42
44
46
33
35
36
36
40
41
23
25
27
27
36
38
1m
1m
Microphone
Notes:
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.
ARNU09GSE*2 ARNU07GSE*2 ARNU12GSE*2
ARNU15GSE*2 ARNU18GS5*2 ARNU24GS5*2
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l
(
d
B

r
e

2
0

P
a

)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l
(
d
B

r
e

2
0

P
a

)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l
(
d
B

r
e

2
0

P
a

)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l
(
d
B

r
e

2
0

P
a

)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l
(
d
B

r
e

2
0

P
a

)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l
(
d
B

r
e

2
0

P
a

)
40
Octave Band Center Frequency (Hz)
Octave Band Center Frequency (Hz)
Octave Band Center Frequency (Hz)
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
Indoor unit
Wall Mounted
7-16 7-16
W
a
l
l

M
o
u
n
t
e
d
10. Installation
Please read the instruction sheetss completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
Installation Parts Provided
1. Type "A" screw
2. Installation Plate
Required Parts Required Tools
Installation plate
Four type "A" screws
Connecting cable
Level gauge
Screw driver
Electric drill
Hole core drill
Pipes: Gas side
Liquid side
Insulation materials
Additional drain pipe
Flaring tool set
Specified torque wrenches
Spanner......................................................Half union
A glass of water
Screw driver
Thermometer
Indoor unit
Wall Mounted
7-17 7-17
W
a
l
l

M
o
u
n
t
e
d
10.1 Selection of the best location
There should not be any heat source or steam near
the unit.
There should not be any obstacles to prevent air cir-
culation.
A place where air circulation in the room will be
good.
A place where drainage can be easily obtained.
A place where noise prevention is taken into consid-
eration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall,
ceiling, fence, or other obstacles.
The mounting wall should be strong and solid enough to
protect it from vibration.
1. Mount the installation plate on the wall with four
Type "A" screws.
(If mounting the unit on the concrete wall, consider using
anchor bolts.)
Always mount the Installation plate horizontally by
aligning the marking-off line by means of thread and a
level.
Front
Right Rear right
Rear left
Down right
Left
More than 200mm
More than
100mm
More than 2300mm
More than
100mm
Chassis
Hook
SE chassis
Installation Plate
Type A
S5 chassis
Installation Plate
Chassis
Hook
Type A
Indoor unit
Wall Mounted
7-18 7-18
W
a
l
l

M
o
u
n
t
e
d
Preparing work for installation
I Preparing the indoor unit's piping and drain hose for
installation through the wall.
I Remove the plastic tubing retainer(see illustration
below) and pull the tubing and drain hose away from
chassis.
I Replace the plastic tubing holder in the original position.
1. Route the indoor tubing and the drain hose in the
direction of rear left.
2. Insert the connecting cable into the indoor unit
from the outdoor unit through the piping hole.
I Do not connect the cable to the indoor unit.
I Make a small loop with the cable for easy connection
later.
3. Tape the tubing, drain hose and the connecting
cable. Be sure that the drain hose is located at the
lowest side of the bundle. Locating at the upper
side can cause drain pan to overflow inside the
unit.
NOTE: If the drain hose is routed inside the room, insulate
the hose with an insulation material* so that dripping from
"sweating"(condensation) will not damage furniture or
floors.
*Foamed polyethylene or equivalent is recommended.
4. Indoor unit installation
I Hook the indoor unit onto the upper portion of the
installation plate.(Engage the two hooks of the rear
top of the indoor unit with the upper edge of the
installation plate.) Ensure that the hooks are properly
seated on the installation plate by moving it left and
right.
Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots(clicking sound).
5. Connecting the pipings to the indoor unit and drain
hose to drain pipe.
I Align the center of the pipings and sufficiently tighten
the flare nut by hand.
For left rear piping
While installing, make sure that the
remaining parts must be removed
clearly so as not to damage the piping
and drain hose, especially power cord
and connecting cable.
To remove the holder,
press the bottom of
chassis near the holder
upward and pull the tab
out of its hole.
Tubing holder
Pull
Press
2
1
Drain hose
Connecting
cable
Loop
Gas side
piping
Liquid side
piping
Drain hose
Drain hose
Connecting
cable
Indoor unit tubing Flare nut Pipings
CAUTION
Indoor unit
Wall Mounted
7-19 7-19
W
a
l
l

M
o
u
n
t
e
d
I Tighten the flare nut with a wrench.
I When extending the drain hose at the indoor unit,
install the drain pipe.
6. Wrap the insulation material around the connect-
ing portion.
I Overlap the connection pipe insulation material
and the indoor unit pipe insulation material. Bind
them together with vinyl tape so that there is no
gap.
I Wrap the area which accommodates the rear pip-
ing housing section with vinyl tape.
I Bundle the piping and drain hose together by
wrapping them with vinyl tape over the range with-
in which they fit into the rear piping housing sec-
tion.
1. Route the indoor tubing and the drain hose to the
required piping hole position.
2. Insert the piping, drain hose and the connecting
cable into the piping hole.
For right rear piping
Torque
wrench
Indoor
unit tubing
Spanner (fixed)
Connection
pipe
Flare nut
Vinyl tape(narrow)
Connection
pipe
Connecting cable
Vinyl tape
(wide)
Wrap with vinyl tape
Indoor
unit pipe
Pipe
Wrap with vinyl tape
Drain hose
Pipe
Vinyl tape(wide)
Drain pipe
Connecting
cable
Vinyl tape(narrow)
Adhesive
Drain pipe
Indoor unit
drain hose
Plastic bands
Insulation material
Indoor unit
Wall Mounted
7-20 7-20
W
a
l
l

M
o
u
n
t
e
d
3. Insert the connecting cable into the indoor unit.
I Don't connect the cable to the indoor unit.
I Make a small loop with the cable for easy connec-
tion later.
4. Tape the drain hose and the connecting cable.
Connecting cable
5. Indoor unit installation
I Hang the indoor unit from the hooks at the top of
the installation plate.
I Insert the spacer etc. between the indoor unit and
the installation plate and separate the bottom of the
indoor unit from the wall.
6. Connecting the pipings to the indoor unit and the
drain hose to drain pipe.
I Align the center of the pipings and sufficiently tight-
en the flare nut by hand.
I Tighten the flare nut with a wrench.
I When extending the drain hose at the indoor unit,
install the drain pipe.
7. Wrap the insulation material around the connect-
ing portion.
I Overlap the connecting pipe heat insulation and the
indoor unit pipe heat insulation material. Bind them
together with vinyl tape so that there is no gap.
I Wrap the area which accommodates the rear piping
housing section with vinyl tape.
Vinyl tape
Adhesive
Drain hose
Indoor unit drain hose
(narrow)
Plastic bands
Insulation material
Vinyl tape
(narrow)
Connection
pipe
Connecting
cable
Indoor
unit piping
Pipe
Vinyl tape
(wide)
Wrap with vinyl tape
Installation plate
Spacer
Indoor unit
80mm
(2-3/16 inch)
Indoor unit tubing Flare nut Pipings
Torque
wrench
Indoor
unit tubing
Spanner (fixed)
Connection
pipe
Flare nut
Indoor unit
Wall Mounted
7-21 7-21
W
a
l
l

M
o
u
n
t
e
d
I Bundle the piping and drain hose together by wrap-
ping them with cloth tape over the range within
which they fit into the rear piping housing section.
8. Reroute the pipings and the drain hose across the
back of the chassis.
9. Set the pipings and the drain hose to the back of
the chassis with the tubing holder.
I Hook the edge of tubing holder to tap on chassis
and push the bottom of tubing holder to be
engaged at the bottom of chassis.
10. Indoor unit installation
I Remove the spacer.
I Ensure that the hooks are properly seated on the
installation plate by moving it left and right.
Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots(clicking sound).
Drain hose
Vinyl tape
(narrow)
Pipe
Wrap with
vinyl tape(wide) Drain hose
Connecting
cable
Piping for
passage through
piping hole
Tubing holder
Hook
Push 2
1
Indoor unit
Wall Mounted
7-22 7-22
W
a
l
l

M
o
u
n
t
e
d
10.2 Connection of Pipings
1. To remove the front panel from the indoor unit,
remove the front panel from the indoor unit
cabinet.
I Set the air direction louvers up-and-down to the
position(horizontally) by hand.
I Remove the securing screws that retain the front
panel. Pull the lower left and right sides of the grille
toward you and lift it off.
(2.1/7, 2.6/9, 3.5/12 kW/Btu models: 2EA,
3.5/18 kW/Btu models: 3EA)
2. To check the drainage.
I Pour a glass of water on the evaporator.
I Ensure the water flows through the drain hose of the
indoor unit without any leakage and goes out the
drain exit.
Pull the right and
the left side.
Screw
10.3 Connect the cable to the
indoor unit
1. Connect the wires to the terminals on the
control board individually according to the
outdoor unit connection.
Ensure that the color of the wires of outdoor
unit and the terminal No. are the same as those
of indoor unit respectively.
Connecting cable
Remote co Remote control cord
Indoor unit
Wall Mounted
7-23 7-23
W
a
l
l

M
o
u
n
t
e
d
2. Attach the Grille onto the cabinet.
Grasp lower the left and right side of the Grille
and engage four tabs on the top inside edge of
the chassis.
Press the Grille toward the chassis until it is
back in place.
Terminal Block Indoor
1(L) 2(N) 3 4
INDOOR POWER INPUT
A - - - - - - B A B
GND 12V DRY2 DRY1 INTERNET IDU SODU Outdoor
Unit
After the confirmation of the above conditions, prepare the wiring as follows:
1) As for the method of wiring, follow the circuit diagram posted on the inside of control cover.
2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from
vibrations to which the unit is subjected during the course of transportation. Check them and
make sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the
wires.)
3) Confirm the specification of power source.
4) Confirm that electrical capacity is sufficient.
5) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked
on the name plate.
6) Confirm that the cable thickness is as specified in the power source specification.
(Particularly note the relation between the cable length and thickness.)
7) In a wet or moist area, always install an earth leakage circuit breaker.
8) The following would be caused by voltage drop.
Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the
normal function of the overload.
9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and
have an air gap contact separation of at least 3mm in each active(phase) conductor.
CAUTION
Indoor unit
Wall Mounted
7-24 7-24
W
a
l
l

M
o
u
n
t
e
d
WIRED REMOTE CONTROLLER INSTALLATION
Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place away
from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
Fig.1 Typical locations for remote controller
5feet
(1.5meters)
no
no
no
yes
Remote Controller
TEMP
Remote Controller
TEMP
Remote Controller
TEMP
Indoor unit
Wall Mounted
7-25 7-25
W
a
l
l

M
o
u
n
t
e
d
11. Accessories
Name
Quantity
Shape
Installation panel
1 set
Type "A" screw
SE: 6 EA
S5: 8 EA
(Other)
Owner's manual
Installation manual
Standard Accessories
SE
S5
Use only those accessories (Standard or optional) which have designated specifications.
CAUTION
Indoor unit
ART COOL Mirror
A
R
T

C
O
O
L

M
i
r
r
o
r
1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. Air Velocity and Temperature Distribution
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories
ART COOL Mirror
Indoor unit
ART COOL Mirror
8-1 8-1
A
R
T

C
O
O
L

M
i
r
r
o
r
1. List of functions
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Air flow
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Air purifying Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
Installation
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Reliability Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Convenience Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Individual
Simple wired remote controller
control
Wired remote controller(for hotel use)
Wireless LCD remote control
Special
Zone control
function kit
CTIE
Electro thermostat
1
Auto
Auto
Auto
X
3 / 4 / 3
O
O
O
-
X
Option
O
-
-
-
-
O
O
O
O(Heat recovery)
O
O(Heat pump or Cooling only)
O
O
O
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
Accessory
-
-
-
Function Category
ARNU07GSE*2, ARNU09GSE*2, ARNU12GSE*2
ARNU15GSE*2, ARNU18GS8*2, ARNU24GS8*2
O : Applied X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.
Indoor unit
ART COOL Mirror
8-2 8-2
A
R
T

C
O
O
L

M
i
r
r
o
r
2. Specifications
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Fan Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Front Panel('*' Position)
ART COOL Mirror
ARNU07GSE*2 ARNU09GSE*2 ARNU12GSE*2
2.2 2.8 3.6
1,900 2,400 3,100
7,500 9,600 12,300
2.5 3.2 4.0
2,200 2,800 3,400
8,500 10,900 13,600
915 x 169 x 282 915 x 169 x 282 915 x 169 x 282
36.0 x 6.5 x 11.1 36.0 x 6.5 x 11.1 36.0 x 6.5 x 11.1
2 x 15 x 18 2 x 15 x 18 2 x 15 x 18
0.21 0.21 0.21
Cross Flow Fan Cross Flow Fan Cross Flow Fan
20 20 20
0.2 0.2 0.2
7.0 / 6.0 / 4.0 8.0 / 7.0 / 5.0 10.0 / 8.0 / 6.0
247 / 212 / 141 282 / 247 / 177 353 / 283 / 212
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene
Resin Net(washable) Resin Net(washable) Resin Net(washable)
Fuse Fuse Fuse
6.35(1/4) 6.35(1/4) 6.35(1/4)
12.7(1/2) 12.7(1/2) 12.7(1/2)
16(5/8) 16(5/8) 16(5/8)
11.2(24.7) 11.2(24.7) 11.2(24.7)
37 / 33 / 23 39 / 35 / 25 41 / 36 / 27
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
R:Mirror V:Silver B:Blue
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Indoor unit
ART COOL Mirror
8-3 8-3
A
R
T

C
O
O
L

M
i
r
r
o
r
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Fan Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Front Panel('*' Position)
ART COOL Mirror
ARNU15GSE*2 ARNU18GS8*2 ARNU24GS8*2
4.5 5.6 7.1
3,900 4,800 6,100
15,400 19,100 24,200
5.0 6.3 8.0
4,300 5,400 6,900
17,100 21,500 27,300
915 x 169 x 282 1,107 x 200 x 299 1,107 x 200 x 299
36.0 x 6.5 x 11.1 43.9 x 7.9 x 11.8 43.9 x 7.9 x 11.8
2 x 15 x 18 2 x 15 x 20 2 x 15 x 20
0.21 0.26 0.26
Cross Flow Fan Cross Flow Fan Cross Flow Fan
20 20 20
0.2 0.2 0.2
10.5 / 8.0 / 6.0 14.4 / 13.0 / 11.0 17.9 / 14.4 / 12.0
371 / 283 / 212 508 / 459 / 388 632 / 508 / 424
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene
Resin Net(washable) Resin Net(washable) Resin Net(washable)
Fuse Fuse Fuse
6.35(1/4) 6.35(1/4) 9.52(3/8)
12.7(1/2) 12.7(1/2) 15.88(5/8)
16(5/8) 16(5/8) 16(5/8)
11.2(24.7) 15(33.1) 15(33.1)
42 / 36 / 27 37 / 34 / 31 43 / 37 / 32
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
R:Mirror V:Silver B:Blue
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Indoor unit
ART COOL Mirror
8-4 8-4
A
R
T

C
O
O
L

M
i
r
r
o
r
3. Dimensions
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

S
E
A
R
T

C
O
O
L

M
i
r
r
o
r
A
R
N
U
0
7
G
S
E
*
2
A
R
N
U
0
9
G
S
E
*
2
A
R
N
U
1
2
G
S
E
*
2
A
R
N
U
1
5
G
S
E
*
2
W
M
o
d
e
l
A
R
N
U
0
7
G
S
E
*
2
A
R
N
U
0
9
G
S
E
*
2
A
R
N
U
1
2
G
S
E
*
2
A
R
N
U
1
5
G
S
E
*
2
H
D
9
1
5

2
8
2
1
6
9
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
(
u
n
i
t

:

m
m
)
9
1
5
2 8 2
2 6 5
2 8 2
1
6
9
5
1
5 3
1 6 5
H
W
D
5
6
7
1
2
N
a
m
e



1
A
i
r

d
i
s
c
h
a
r
g
e

g
r
i
l
l




2
A
i
r

s
u
c
t
i
o
n

g
r
i
l
l

N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
(
u
n
i
t

:

m
m
)
Indoor unit
ART COOL Mirror
8-5 8-5
A
R
T

C
O
O
L

M
i
r
r
o
r
D
i
s
p
l
a
y

&

s
i
g
n
a
l

r
e
c
e
i
v
e
r
P
a
r
t

N
a
m
e
F
r
o
n
t

p
a
n
e
l
A
i
r

s
u
c
t
i
o
n

g
r
i
l
l
e
I
n
s
t
a
l
l
a
t
i
o
n

p
l
a
t
e
K
n
o
c
k
o
u
t

h
o
l
e
5



N
o
.
24 3 1
R
e
m
a
r
k
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
31
2
4
2 9 9
4 8
9 3
2 8 1
1
2
2
2
0
0
1
1
0
7
8
0
4
1 0
6 3
5
3
5
8
7
2
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

S
8
A
R
T

C
O
O
L

M
i
r
r
o
r
A
R
N
U
1
8
G
S
8
*
2
A
R
N
U
2
4
G
S
8
*
2
(
u
n
i
t

:

m
m
)
Indoor unit
ART COOL Mirror
8-6 8-6
A
R
T

C
O
O
L

M
i
r
r
o
r
4. Piping Diagrams
Heat Exchanger
C.F.F
lndoor unit
EEV
:Heating
:Cooling
Filter
Filter
Th3
Th1
Th2
Refrigerant pipe connection port diameter
*Panel Color (SE/S8 chassis) : R(Mirror),V(Silver), B(Blue)
MODEL GAS LIQUID
ARNU07GSE*2 12.7(1/2) 6.35(1/4)
ARNU09GSE*2 12.7(1/2) 6.35(1/4)
ARNU12GSE*2 12.7(1/2) 6.35(1/4)
ARNU15GSE*2 12.7(1/2) 6.35(1/4)
ARNU18GS8*2 12.7(1/2) 6.35(1/4)
ARNU24GS8*2 15.88(5/8) 9.52(3/8)
[Unit: mm(inch)]
LOC. Description PCB Connector
Th1 Room thermistor
CN-TH1
Th2 Pipe in thermistor
Th3 Pipe out thermistor CN-TH2
Indoor unit
ART COOL Mirror
8-7 8-7
A
R
T

C
O
O
L

M
i
r
r
o
r
5. Wiring Diagrams
CONNECTOR NUMBER LOCATION POINT FUNCTION
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-COM Communication Communication between indoor and outdoor
CN-EEV EEV output EEV control output
CN-L/R Step motor Step motor output for left/right
CN-U/D Step motor Step motor output
CN-TH1 Room/pipe sensor Room & pipe thermistor
CN-TH2 Discharge pipe sensor Discharge pipe thermistor
CN-SUC Step motor(front) Front panel step motor
CN-HVB Air purifier Air purifier output
CN-VFD Display Display of indoor status
CN-12V Safety connection Safety of indoor status
CN-REMO Remote controller Remote control line
CN-CC Dry contact Dry contact line
CN-HVB Air clean Air clean control
SE/S8 Chassis
Indoor unit
ART COOL Mirror
8-8 8-8
A
R
T

C
O
O
L

M
i
r
r
o
r
6. Capacity Tables
6.1 Cooling Capacity
Cooling Capacity
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.7 2.8
12 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.7 2.7
14 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.6 2.7
16 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.6 2.7
18 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.5 2.6
20 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.4 2.6
21 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.4 2.6
23 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.3 2.5
25 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.2 2.8 4.3 2.5
27 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.7 4.2 2.5
29 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.7 4.2 2.4
31 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.6 4.1 2.4
33 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.6 4.0 2.4
35 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 3.9 2.5 4.0 2.3
37 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.8 2.5 3.9 2.3
39 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.7 2.4 3.8 2.2
2.8
3.6
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
10 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.9 1.7
12 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.9 1.6
14 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.8 1.6
16 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.8 1.6
18 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.6
20 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.6
21 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.5
23 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.6 1.5
25 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.6 1.5
27 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.6 1.5
29 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.5 1.5
31 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.5 1.4
33 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.4 1.5 2.5 1.4
35 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.4 1.5 2.4 1.4
37 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.3 1.5 2.4 1.4
39 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.2 1.5 2.3 1.5 2.3 1.4
10 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.7 2.1
12 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.6 2.1
14 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.6 2.1
16 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.5 2.0
18 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.5 2.0
20 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 2.0
21 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 2.0
23 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 1.9
25 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.3 2.1 3.3 1.9
27 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 2.1 3.3 1.9
29 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 2.0 3.2 1.9
31 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.1 2.0 3.2 1.8
33 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.1 2.0 3.1 1.8
35 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.0 1.9 3.1 1.8
37 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 3.0 1.9 3.0 1.8
39 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 2.9 1.9 3.0 1.7
2.2
Indoor unit
ART COOL Mirror
8-9 8-9
A
R
T

C
O
O
L

M
i
r
r
o
r
Cooling Capacity
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.3 5.5
12 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.2 5.5
14 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.1 5.4
16 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.0 5.3
18 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.8 5.2
20 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.7 5.2
21 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.7 5.1
23 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.5 5.1
25 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.4 5.5 8.4 5.0
27 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.2 5.4 8.3 4.9
29 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.1 5.3 8.2 4.8
31 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.0 5.2 8.1 4.8
33 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 7.8 5.1 7.9 4.7
35 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 7.7 5.0 7.8 4.6
37 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.4 5.2 7.5 4.9 7.7 4.6
39 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.2 5.1 7.4 4.8 7.6 4.5
5.6
7.1
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
10 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.9 3.5
12 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.8 3.4
14 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.8 3.4
16 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.7 3.3
18 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.6 3.3
20 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.5 3.2
21 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.5 3.2
23 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.4 3.2
25 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.3 3.1
27 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.3 3.1
29 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.2 3.0
31 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.1 3.0
33 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.0 2.9
35 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 5.0 2.9
37 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 4.9 2.9
39 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.5 4.8 2.8
10 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.4 4.3
12 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.3 4.2
14 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.2 4.2
16 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.1 4.1
18 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.0 4.1
20 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.9 4.0
21 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.8 4.0
23 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.7 3.9
25 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.6 4.3 6.6 3.9
27 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.4 4.2 6.6 3.8
29 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.4 4.1 6.5 3.8
31 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.3 4.1 6.4 3.7
33 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.2 4.0 6.3 3.7
35 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.0 3.9 6.2 3.6
37 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 5.8 4.1 5.9 3.8 6.1 3.6
39 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 5.7 4.0 5.8 3.8 6.0 3.5
4.5
Indoor unit
ART COOL Mirror
8-10 8-10
A
R
T

C
O
O
L

M
i
r
r
o
r
6.2 Heating Capacity
Heating Capacity
Notes: TC: Total Capacity(kW)
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 1.7 1.7 1.7 1.7 1.7 1.7
-18.8 -19.0 1.7 1.7 1.7 1.7 1.7 1.7
-16.7 -17.0 1.8 1.8 1.8 1.8 1.8 1.8
-14.7 -15.0 1.9 1.9 1.7 1.9 1.9 1.9
-12.6 -13.0 2.0 2.0 1.8 2.0 2.0 2.0
-10.5 -11.0 2.1 2.1 1.9 2.1 2.1 2.1
-9.5 -10.0 2.2 2.2 1.9 2.2 2.2 2.1
-8.5 -9.1 2.2 2.2 2.0 2.2 2.2 2.1
-7.0 -7.6 2.3 2.3 2.0 2.2 2.2 2.2
-5.0 -5.6 2.4 2.4 2.1 2.3 2.3 2.2
-3.0 -3.7 2.5 2.5 2.2 2.4 2.4 2.2
0.0 -0.7 2.6 2.6 2.3 2.4 2.4 2.2
3.0 2.2 2.8 2.7 2.4 2.4 2.4 2.2
5.0 4.1 2.8 2.7 2.5 2.4 2.4 2.2
7.0 6.0 2.9 2.7 2.5 2.4 2.4 2.2
9.0 7.9 2.9 2.7 2.5 2.4 2.4 2.2
11.0 9.8 2.9 2.7 2.5 2.4 2.4 2.2
13.0 11.8 2.9 2.7 2.5 2.4 2.4 2.2
15.0 13.7 2.9 2.7 2.5 2.4 2.4 2.2
-19.8 -20.0 2.1 2.1 2.1 2.1 2.1 2.1
-18.8 -19.0 2.2 2.2 2.2 2.2 2.2 2.2
-16.7 -17.0 2.3 2.3 2.3 2.3 2.3 2.3
-14.7 -15.0 2.5 2.4 2.2 2.4 2.4 2.4
-12.6 -13.0 2.6 2.6 2.3 2.6 2.6 2.6
-10.5 -11.0 2.7 2.7 2.4 2.7 2.7 2.7
-9.5 -10.0 2.8 2.8 2.5 2.8 2.8 2.7
-8.5 -9.1 2.8 2.8 2.5 2.8 2.8 2.7
-7.0 -7.6 2.9 2.9 2.6 2.8 2.8 2.8
-5.0 -5.6 3.0 3.0 2.7 3.0 3.0 2.8
-3.0 -3.7 3.2 3.2 2.8 3.1 3.0 2.8
0.0 -0.7 3.4 3.4 3.0 3.1 3.0 2.8
3.0 2.2 3.6 3.4 3.1 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.7 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.7 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.7 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.7 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.7 3.4 3.2 3.1 3.0 2.8
-19.8 -20.0 2.7 2.7 2.7 2.6 2.6 2.6
-18.8 -19.0 2.8 2.8 2.8 2.8 2.7 2.7
-16.7 -17.0 2.9 2.9 2.9 2.9 2.9 2.9
-14.7 -15.0 3.1 3.0 2.7 3.0 3.0 3.0
-12.6 -13.0 3.2 3.2 2.9 3.2 3.2 3.2
-10.5 -11.0 3.4 3.4 3.0 3.4 3.4 3.4
-9.5 -10.0 3.4 3.4 3.1 3.4 3.4 3.4
-8.5 -9.1 3.5 3.5 3.2 3.5 3.5 3.4
-7.0 -7.6 3.6 3.6 3.3 3.6 3.6 3.5
-5.0 -5.6 3.8 3.8 3.4 3.7 3.7 3.5
-3.0 -3.7 4.0 4.0 3.5 3.9 3.8 3.5
0.0 -0.7 4.2 4.2 3.7 3.9 3.8 3.5
3.0 2.2 4.4 4.3 3.9 3.9 3.8 3.5
5.0 4.1 4.5 4.3 4.0 3.9 3.8 3.5
7.0 6.0 4.6 4.3 4.0 3.9 3.8 3.5
9.0 7.9 4.6 4.3 4.0 3.9 3.8 3.5
11.0 9.8 4.6 4.3 4.0 3.9 3.8 3.5
13.0 11.8 4.6 4.3 4.0 3.9 3.8 3.5
15.0 13.7 4.6 4.3 4.0 3.9 3.8 3.5
2.2
2.8
3.6
Indoor unit
ART COOL Mirror
8-11 8-11
A
R
T

C
O
O
L

M
i
r
r
o
r
Heating Capacity
Notes: TC: Total Capacity(kW)
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 3.4 3.4 3.4 3.3 3.3 3.3
-18.8 -19.0 3.5 3.5 3.5 3.5 3.4 3.4
-16.7 -17.0 3.7 3.7 3.7 3.7 3.7 3.6
-14.7 -15.0 3.9 3.8 3.4 3.8 3.8 3.8
-12.6 -13.0 4.1 4.1 3.6 4.0 4.0 4.0
-10.5 -11.0 4.3 4.3 3.8 4.3 4.2 4.2
-9.5 -10.0 4.3 4.3 3.9 4.3 4.3 4.3
-8.5 -9.1 4.4 4.4 4.0 4.4 4.4 4.3
-7.0 -7.6 4.6 4.6 4.1 4.4 4.4 4.4
-5.0 -5.6 4.8 4.8 4.3 4.6 4.6 4.4
-3.0 -3.7 5.0 5.0 4.4 4.8 4.7 4.4
0.0 -0.7 5.3 5.3 4.6 4.8 4.7 4.4
3.0 2.2 5.6 5.4 4.9 4.8 4.7 4.4
5.0 4.1 5.6 5.4 5.0 4.8 4.7 4.4
7.0 6.0 5.8 5.4 5.0 4.8 4.7 4.4
9.0 7.9 5.8 5.4 5.0 4.8 4.7 4.4
11.0 9.8 5.8 5.4 5.0 4.8 4.7 4.4
13.0 11.8 5.8 5.4 5.0 4.8 4.7 4.4
15.0 13.7 5.8 5.4 5.0 4.8 4.7 4.4
-19.8 -20.0 4.2 4.2 4.2 4.2 4.2 4.2
-18.8 -19.0 4.3 4.3 4.3 4.3 4.3 4.3
-16.7 -17.0 4.6 4.6 4.6 4.6 4.6 4.5
-14.7 -15.0 4.9 4.8 4.3 4.8 4.8 4.8
-12.6 -13.0 5.1 5.1 4.5 5.0 5.0 5.0
-10.5 -11.0 5.4 5.4 4.8 5.4 5.3 5.3
-9.5 -10.0 5.4 5.4 4.9 5.4 5.4 5.4
-8.5 -9.1 5.5 5.5 5.0 5.5 5.5 5.4
-7.0 -7.6 5.7 5.7 5.1 5.6 5.6 5.5
-5.0 -5.6 6.0 6.0 5.4 5.8 5.8 5.5
-3.0 -3.7 6.2 6.2 5.5 6.1 5.9 5.5
0.0 -0.7 6.6 6.6 5.8 6.1 5.9 5.5
3.0 2.2 7.0 6.7 6.2 6.1 5.9 5.5
5.0 4.1 7.1 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.2 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.2 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.2 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.2 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.2 6.7 6.3 6.1 5.9 5.5
-19.8 -20.0 5.4 5.4 5.4 5.3 5.3 5.3
-18.8 -19.0 5.5 5.5 5.5 5.5 5.4 5.4
-16.7 -17.0 5.8 5.8 5.8 5.8 5.8 5.8
-14.7 -15.0 6.2 6.1 5.5 6.1 6.1 6.1
-12.6 -13.0 6.5 6.5 5.8 6.4 6.4 6.4
-10.5 -11.0 6.8 6.8 6.0 6.8 6.7 6.7
-9.5 -10.0 6.9 6.9 6.2 6.9 6.9 6.8
-8.5 -9.1 7.0 7.0 6.3 7.0 7.0 6.8
-7.0 -7.6 7.3 7.3 6.5 7.1 7.1 7.0
-5.0 -5.6 7.6 7.6 6.8 7.4 7.4 7.0
-3.0 -3.7 7.9 7.9 7.0 7.7 7.5 7.0
0.0 -0.7 8.4 8.4 7.4 7.8 7.5 7.0
3.0 2.2 8.9 8.6 7.8 7.8 7.5 7.0
5.0 4.1 9.0 8.6 8.0 7.8 7.5 7.0
7.0 6.0 9.2 8.6 8.0 7.8 7.5 7.0
9.0 7.9 9.2 8.6 8.0 7.8 7.5 7.0
11.0 9.8 9.2 8.6 8.0 7.8 7.5 7.0
13.0 11.8 9.2 8.6 8.0 7.8 7.5 7.0
15.0 13.7 9.2 8.6 8.0 7.8 7.5 7.0
4.5
5.6
7.1
Indoor unit
ART COOL Mirror
8-12 8-12
A
R
T

C
O
O
L

M
i
r
r
o
r
7. Air Velocity and Temperature Distribution
Cooling
Discharge angle:45
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
1.0
2.0
1.5
0.5
21
24
27
30
33
Heating
Discharge angle:60
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
1.0
2.0
1.5
0.5
24
22
20
18
ARNU12GSE*2
Cooling
Discharge angle:45
Heating
Discharge angle:60
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
1.0
2.0
1.5
0.5
24
22
20
18
Air velocity [m/s]
Temperature [C]
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
2.7m
2m
1m
0m
5m 4m 3m 2m 1m 0m
1.0
2.0
1.5
0.5
21
24
27
30
33
ARNU07GSE*2
Indoor unit
ART COOL Mirror
8-13 8-13
A
R
T

C
O
O
L

M
i
r
r
o
r
8. Electric Characteristics
Symbols:
MCA : Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor
Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA
MFA 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the MCA.
Units
Model Type Hz Volts Voltage Range
ARNU07GSE*2 SE 0.29 15 0.02 0.23 40 40
ARNU09GSE*2 SE 0.29 15 0.02 0.23 40 40
ARNU12GSE*2 SE
50 220 - 240
Max:264 0.29 15 0.02 0.23 40 40
ARNU15GSE*2 SE Min:198 0.29 15 0.02 0.23 40 40
ARNU18GS8*2 S8 0.29 15 0.02 0.23 35 35
ARNU24GS8*2 S8 0.29 15 0.02 0.23 35 35
ARNU07GSE*2 SE 0.29 15 0.02 0.23 40 40
ARNU09GSE*2 SE 0.29 15 0.02 0.23 40 40
ARNU12GSE*2 SE
60 220
Max:242 0.29 15 0.02 0.23 40 40
ARNU15GSE*2 SE Min:198 0.29 15 0.02 0.23 40 40
ARNU18GS8*2 S8 0.29 15 0.02 0.23 35 35
ARNU24GS8*2 S8 0.29 15 0.02 0.23 35 35
Power Supply IFM Input(W)
MCA MFA kW FLA Cooling Heating
Indoor unit
ART COOL Mirror
8-14 8-14
A
R
T

C
O
O
L

M
i
r
r
o
r
9. Sound Levels
Overall
Sound Pressure Level
Model
ARNU07GSE*2
ARNU09GSE*2
ARNU12GSE*2
ARNU15GSE*2
ARNU18GS8*2
ARNU24GS8*2
Sound Levels dB(A)
H M L
37
39
41
42
37
43
33
35
36
36
34
37
23
25
27
27
31
32
1m
1m
Microphone
Notes:
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.
ARNU07GSE*2 ARNU09GSE*2
ARNU15GSE*2
ARNU12GSE*2
ARNU18GS8*2 ARNU24GS8*2
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l
(
d
B

r
e

2
0

P
a

)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l
(
d
B

r
e

2
0

P
a

)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l
(
d
B

r
e

2
0

P
a

)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l
(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l
(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l
(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
Indoor unit
ART COOL Mirror
8-15 8-15
A
R
T

C
O
O
L

M
i
r
r
o
r
10. Installation
Please read this instruction sheet completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
Installation Parts Provided
1. Type "A" screw
2. Installation Plate
Required Parts Required Tools
Installation plate
Four type "A" screws
Connecting cable
Level gauge
Screw driver
Electric drill
Hole core drill
Pipes: Gas side
Liquid side
Insulation materials
Additional drain pipe
Flaring tool set
Specified torque wrenches
Spanner......................................................Half union
A glass of water
Screw driver
Thermometer
Indoor unit
ART COOL Mirror
8-16 8-16
A
R
T

C
O
O
L

M
i
r
r
o
r
10.1 Selection of the best location
There should not be any heat source or steam near the
unit.
There should not be any obstacles to prevent the air cir-
culation.
A place where air circulation in the room will be good.
A place where drainage can be easily obtained.
A place where noise prevention is taken into considera-
tion.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall, ceil-
ing, fence, or other obstacles.
The mounting wall should be strong and solid enough to
protect it from the vibration.
Mount the installation plate on the wall with four Type
"A" screws.
(If mounting the unit on the concrete wall, consider using
anchor bolts.)
Always mount the Installation plate horizontally by
aligning the marking-off line by means of the thread
and a level.
More than 200mm
More than 100mm
More than 2300mm
More than 100mm
70mm
1
1
0
m
m
70mm
1
1
0
m
m
65mm
85mm
Chassis
Hook
Installation Plate
Type A
SE chassis
SE chassis
Installation plate
Left rear piping Right rear piping
S8 chassis
Chassis
Hook
Installation Plate
Type A
S8 chassis
Installation plate
Left rear piping Right rear piping
70mm
133mm
70mm
100mm
The lower left and the right side of Installation Plate
CAUTION : In case that the unit is installed near the sea, the installation parts
may be corroded by salt. The installation parts (and the unit) should be taken
appropriate anti-corrosion measures.
Indoor unit
ART COOL Mirror
8-17 8-17
A
R
T

C
O
O
L

M
i
r
r
o
r
I Preparing the indoor unit's piping and drain hose for
installation through the wall.
I Remove the plastic tubing retainer(see illustration
below) and pull the tubing and drain hose away from
chassis.
I Replace the plastic tubing holder in the original position.
1. Route the indoor tubing and the drain hose in the
direction of rear left.
2. Insert the connecting cable into the indoor unit
from the outdoor unit through the piping hole.
I Do not connect the cable to the indoor unit.
I Make a small loop with the cable for easy connection
later.
3. Tape the tubing, drain hose and the connecting
cable. Be sure that the drain hose is located at the
lowest side of the bundle. Locating at the upper
side can cause drain pan to overflow inside the
unit.
: If the drain hose is routed inside the room,
insulate the hose with an insulation material* so that drip-
ping from "sweating"(condensation) will not damage furni-
ture or floors.
*Foamed polyethylene or equivalent is recommended.
4. Indoor unit installation
I Hook the indoor unit onto the upper portion of the
installation plate.(Engage the two hooks of the rear
top of the indoor unit with the upper edge of the
installation plate.) Ensure that the hooks are properly
seated on the installation plate by moving it left and
right.
Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots(clicking sound).
NOTICE
For right rear piping
Drain hose
Connecting
pipe
Connecting cable
Tape
Drain hose
Drain hose
Connecting
cable
Preparing work for installation
Indoor unit
ART COOL Mirror
8-18 8-18
A
R
T

C
O
O
L

M
i
r
r
o
r
5. Connecting the pipings to the indoor unit and drain
hose to drain pipe.
I Align the center of the pipings and sufficiently tighten
the flare nut by hand.
I Tighten the flare nut with a wrench.
I Mount the clamp on the boss with a type "B"
screw.(optional)
I When extending the drain hose at the indoor
unit, install the drain pipe.
6. Wrap the insulation material around the connect-
ing portion.
I Overlap the connection pipe insulation material
and the indoor unit pipe insulation material. Bind
them together with vinyl tape so that there is no
gap.
I Wrap the area which accommodates the rear pip-
ing housing section with vinyl tape.
I Bundle the piping and drain hose together by
wrapping them with vinyl tape over the range with-
in which they fit into the rear piping housing sec-
tion.
1. Route the indoor tubing and the drain hose to the
required piping hole position.
2. Insert the piping, drain hose and the connecting
cable into the piping hole.
For left rear piping
Torque
wrench
Indoor
unit tubing
Spanner (fixed)
Connection
pipe
Flare nut
Vinyl tape(narrow)
Connection
pipe
Connecting cable
Vinyl tape
(wide)
Wrap with vinyl tape
Indoor
unit pipe
Pipe
Wrap with vinyl tape
Drain hose
Pipe
Vinyl tape(wide)
Drain pipe
Connecting cable
Vinyl tape(narrow)
Adhesive
Drain pipe
Indoor unit
drain hose
Plastic bands
Insulation material
Drain hose
Clamp
Boss
Type "B" screw
Indoor unit tubing Flare nut Pipings
Indoor unit
ART COOL Mirror
8-19 8-19
A
R
T

C
O
O
L

M
i
r
r
o
r
3. Insert the connecting cable into the indoor unit.
I Don't connect the cable to the indoor unit.
I Make a small loop with the cable for easy connec-
tion later.
4. Tape the drain hose and the connecting cable.
Connecting cable
5. Indoor unit installation
I Hang the indoor unit from the hooks at the top of
the installation plate.
I Insert the spacer etc. between the indoor unit and
the installation plate and separate the bottom of
the indoor unit from the wall.
6. Connecting the pipings to the indoor unit and
the drain hose to drain pipe.
I Align the center of the pipings and sufficiently
tighten the flare nut by hand.
I Tighten the flare nut with a wrench.
I When extending the drain hose at the indoor unit,
install the drain pipe.
7. Wrap the insulation material around the connect-
ing portion.
I Overlap the connection pipe heat insulation and
the indoor unit pipe heat insulation material. Bind
them together with vinyl tape so that there is no
gap.
I Wrap the area which accommodates the rear pip-
ing housing section with vinyl tape.
Vinyl tape
Adhesive
Drain hose
Indoor unit drain hose
(narrow)
Plastic bands
Insulation material
Vinyl tape
(narrow)
Connection
pipe
Connecting
cable
Indoor
unit piping
Pipe
Vinyl tape
(wide)
Wrap with vinyl tape
Indoor unit tubing Flare nut Pipings
Torque
wrench
Indoor
unit tubing
Spanner (fixed)
Connection
pipe
Flare nut
Installation plate
Spacer
Indoor unit
80mm
Indoor unit
ART COOL Mirror
8-20 8-20
A
R
T

C
O
O
L

M
i
r
r
o
r
I Bundle the piping and drain hose together by
wrapping them with cloth tape over the range
within which they fit into the rear piping housing
section.
8. Reroute the pipings and the drain hose across
the back of the chassis.
9. Set the pipings and the drain hose to the back of
the chassis with the tubing holder.
I Hook the edge of tubing holder to tap on chassis
and push the bottom of tubing holder to be
engaged at the bottom of chassis.
10. Indoor unit installation
I Remove the spacer.
I Ensure that the hooks are properly seated on the
installation plate by moving it left and right.
Press the lower left and right sides of the unit
against the installation plate until the hooks engage
into their slots(clicking sound).
Drain hose
Vinyl tape
(narrow)
Pipe
Wrap with
vinyl tape(wide)
Piping for
passage through
piping hole
Tubing holder
Drain hose
Connecting
cable
Indoor unit
ART COOL Mirror
8-21 8-21
A
R
T

C
O
O
L

M
i
r
r
o
r
10.2 Connection of Pipings
1. To remove the front panel from the indoor unit,
remove the front panel from the indoor unit
cabinet.
I Set the air direction louvers up-and-down to the
position(horizontally) by hand.
I Remove the securing screws that retain the front
panel. Pull the lower left and right sides of the grille
toward you and lift it off.
2. To check the drainage.
I Pour a glass of water on the evaporator.
I Ensure the water flows through the drain hose of the indoor
unit without any leakage and goes out the drain exit.
Front panel
Drain pan
Drain
hose
Leakage
checking
Connecting area
drain hose
Leakage
checking
10.3 Connect the cable to the
indoor unit
1. Connect the wires to the terminals on the
control board individually according to the
outdoor unit connection.
Ensure that the color of the wires of outdoor
unit and the terminal No. are the same as
those of indoor unit respectively.
Connecting cable
Remote co Remote control cord
I The drain hose should point downward for easy drain flow.
Downward slope
Do not raise
Accumulated
drain water
Tip of drain hose
dipped in water
Air
Waving
Water
leakage
Water
leakage
Ditch
Less than
50mm gap
Water
leakage
I Do not make drain piping.
Indoor unit
ART COOL Mirror
8-22 8-22
A
R
T

C
O
O
L

M
i
r
r
o
r
2. Attach the Grille onto the cabinet.
Grasp lower the left and right side of the Grille
and engage four tabs on the top inside edge of
the chassis.
Press the Grille toward the chassis until it is
back into its original place.
Terminal Block Indoor
1(L1) 2(L2) 3 4
INDOOR POWER INPUT
- -
SODU IDU
B A B A - - - -
INTERNET DRY1 DRY2 GND 12V
Outdoor unit
After the confirmation of the above conditions, prepare the wiring as follows:
1) As for the method of wiring, follow the circuit diagram posted on the inside of control cover.
2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from
vibrations to which the unit is subjected during the course of transportation. Check them and
make sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the
wires.)
3) Specification of power source.
4) Confirm that electrical capacity is sufficient.
5) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked
on the name plate.
6) Confirm that the cable thickness is as specified in the power source specification.
(Particularly note the relation between cable length and thickness.)
7) Always install an earth leakage circuit breaker in a wet or moist area.
8) The following would be caused by voltage drop.
Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the
normal function of the overload.
9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and
have an air gap contact separation of at least 3mm in each active(phase) conductor.
CAUTION
Indoor unit
ART COOL Mirror
8-23 8-23
A
R
T

C
O
O
L

M
i
r
r
o
r
WIRED REMOTE CONTROLLER INSTALLATION
Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place away
from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
Fig.1 Typical locations for remote controller
5feet
(1.5meters)
no
no
no
yes
Remote Controller
TEMP
Remote Controller
TEMP
Remote Controller
TEMP
Indoor unit
ART COOL Mirror
8-24 8-24
A
R
T

C
O
O
L

M
i
r
r
o
r
11. Accessories
Name
Quantity
Shape
SE
S8
Installation panel
1 set
Type "A" screws and
plastic anchors
4 set
(Other)
Owner's manual
Installation manual
Standard Accessories
Use only those accessories (Standard or optional) which have designated specifications.
CAUTION
Indoor unit
ART COOL Gallery
A
R
T

C
O
O
L

G
a
l
l
e
r
y
1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. Electric Characteristics
8. Sound Levels
9. Installation
10. Accessories
ART COOL Gallery
Indoor unit
ART COOL Gallery
9-1 9-1
A
R
T

C
O
O
L

G
a
l
l
e
r
y
1. List of functions
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Air flow
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Air purifying Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
Installation
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Reliability Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Convenience Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Individual Simple wired remote controller
control Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Special
Zone control
function kit
CTIE
Electro thermostat
3
X
Auto
X
O
3 / 4 / 3
X
O
O
-
X
Option
O
-
-
-
-
O
O
O
O(Heat recovery)
O
O(Heat pump or Cooling only)
O
O
O
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
Accessory
Accessory
-
-
-
Function Category ARNU07GSF*2, ARNU09GSF*2, ARNU12GSF*2
O : Applied X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.
Indoor unit
ART COOL Gallery
9-2 9-2
A
R
T

C
O
O
L

G
a
l
l
e
r
y
2. Specifications
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Panel color: E(Red), V(Silver), G(Gold) Panel type
1: Kiss (Photo changeable) Gallery type
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Fan Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Front Panel('*' Position)
ART COOL Gallery
ARNU07GSF*2 ARNU09GSF*2 ARNU12GSF*2
2.2 2.8 3.6
1,900 2,400 3,100
7,500 9,600 12,300
2.5 3.2 4.0
2,200 2,800 3,400
8,500 10,900 13,600
600x146x600 600x146x600 600x146x600
23.6x5.7x23.6 23.6x5.7x23.6 23.6x5.7x23.6
2x20x21 2x20x21 2x20x21
0.18 0.18 0.18
Turbo Fan Turbo Fan Turbo Fan
30 30 30
0.16 0.16 0.16
8.1 / 6.3 / 4.2 8.1 / 6.3 / 4.2 9.3 / 7.7 / 6.0
286 / 222 / 148 286 / 222 / 148 328 / 272 / 212
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene
Resin Net(washable) Resin Net(washable) Resin Net(washable)
Fuse Fuse Fuse
6.35(1/4) 6.35(1/4) 6.35(1/4)
12.7(1/2) 12.7(1/2) 12.7(1/2)
12.2(15/32) 12.2(15/32) 12.2(15/32)
15(33.1) 15(33.1) 15(33.1)
38 / 32 / 27 38 / 32 / 27 44 / 38 / 32
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
E:Red, V:Silver, G:Gold, 1: Kiss (Photo changeable)
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Indoor unit
ART COOL Gallery
9-3 9-3
A
R
T

C
O
O
L

G
a
l
l
e
r
y
3. Dimensions
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

S
F
A
R
T

C
O
O
L

G
a
l
l
e
r
y
A
R
N
U
0
7
G
S
F
*
2
A
R
N
U
0
9
G
S
F
*
2
A
R
N
U
1
2
G
S
F
*
2
W
M
o
d
e
l
A
R
N
U
0
7
G
S
F
*
2
A
R
N
U
0
9
G
S
F
*
2
A
R
N
U
1
2
G
S
F
*
2
H
D
6
0
0
6
0
0
1
4
6
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
(
u
n
i
t

:

m
m
)
P
i
p
e

H
o
l
e
F
i
x

H
o
l
e
H
a
n
g
e
r

H
o
l
e
H
W
D
N
a
m
e



1
A
i
r

d
i
s
c
h
a
r
g
e

g
r
i
l
l




2
A
i
r

s
u
c
t
i
o
n

g
r
i
l
l

N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
(
u
n
i
t

:

m
m
)
1
2
1
1
5
0
0
5 2 5
Indoor unit
ART COOL Gallery
9-4 9-4
A
R
T

C
O
O
L

G
a
l
l
e
r
y
4. Piping Diagrams
Heat Exchanger
Turbo Fan
lndoor unit
EEV :Heating
:Cooling
Filter
Filter
Th3
Th1
Th2
Refrigerant pipe connection port diameter
*Panel color :E(Red), V(Silver), G(Gold), 1(Kiss (Photo changeable))
Model
ARNU07GSF*2 12.7(1/2) 6.35(1/4)
ARNU09GSF*2 12.7(1/2) 6.35(1/4)
ARNU12GSF*2 12.7(1/2) 6.35(1/4)
Gas Liquid
[Unit: mm(inch)]
LOC. Description PCB Connector
Th1 Room thermistor
CN-TH1
Th2 Pipe in thermistor
Th3 Pipe out thermistor CN-TH1
Indoor unit
ART COOL Gallery
9-5 9-5
A
R
T

C
O
O
L

G
a
l
l
e
r
y
5. Wiring Diagrams
CONNECTOR NUMBER LOCATION POINT FUNCTION
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-COM Communication Communication between indoor and outdoor
CN-EEV EEV output EEV control output
CN-D1 Display Display of indoor status
CN-LR1 Step motor Step motor output for left/right
CN-LR2 Step motor Step motor output for left/right
CN-UD Step motor Step motor output
CN-TH1 Room/pipe sensor Room and pipe thermistor
CN-TH2 Discharge pipe sensor Discharge pipe thermistor
CN-REMO Remote controller Remote control line
CN-CC Dry contact Dry contact line
CN-HVB Air clean Air clean control
SF Chassis
Indoor unit
ART COOL Gallery
9-6 9-6
A
R
T

C
O
O
L

G
a
l
l
e
r
y
6. Capacity Tables
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
2.8
3.6
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
10 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.9 1.7
12 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.9 1.6
14 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.8 1.6
16 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.8 1.6
18 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.6
20 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.6
21 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.5
23 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.6 1.5
25 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.6 1.5
27 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.6 1.5
29 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.5 1.5
31 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.5 1.4
33 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.4 1.5 2.5 1.4
35 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.4 1.5 2.4 1.4
37 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.3 1.5 2.4 1.4
39 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.2 1.5 2.3 1.5 2.3 1.4
10 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.7 2.1
12 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.6 2.1
14 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.6 2.1
16 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.5 2.0
18 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.5 2.0
20 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 2.0
21 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 2.0
23 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 1.9
25 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.3 2.1 3.3 1.9
27 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 2.1 3.3 1.9
29 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 2.0 3.2 1.9
31 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.1 2.0 3.2 1.8
33 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.1 2.0 3.1 1.8
35 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.0 1.9 3.1 1.8
37 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 3.0 1.9 3.0 1.8
39 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 2.9 1.9 3.0 1.7
10 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.7 2.8
12 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.7 2.7
14 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.6 2.7
16 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.6 2.7
18 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.5 2.6
20 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.4 2.6
21 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.4 2.6
23 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.3 2.5
25 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.2 2.8 4.3 2.5
27 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.7 4.2 2.5
29 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.7 4.2 2.4
31 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.6 4.1 2.4
33 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.6 4.0 2.4
35 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 3.9 2.5 4.0 2.3
37 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.8 2.5 3.9 2.3
39 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.7 2.4 3.8 2.2
2.2
6.1 Cooling Capacity
Cooling Capacity
Indoor unit
ART COOL Gallery
9-7 9-7
A
R
T

C
O
O
L

G
a
l
l
e
r
y
6.2 Heating Capacity
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 1.7 1.7 1.7 1.7 1.7 1.7
-18.8 -19.0 1.7 1.7 1.7 1.7 1.7 1.7
-16.7 -17.0 1.8 1.8 1.8 1.8 1.8 1.8
-14.7 -15.0 1.9 1.9 1.7 1.9 1.9 1.9
-12.6 -13.0 2.0 2.0 1.8 2.0 2.0 2.0
-10.5 -11.0 2.1 2.1 1.9 2.1 2.1 2.1
-9.5 -10.0 2.2 2.2 1.9 2.2 2.2 2.1
-8.5 -9.1 2.2 2.2 2.0 2.2 2.2 2.1
-7.0 -7.6 2.3 2.3 2.0 2.2 2.2 2.2
-5.0 -5.6 2.4 2.4 2.1 2.3 2.3 2.2
-3.0 -3.7 2.5 2.5 2.2 2.4 2.4 2.2
0.0 -0.7 2.6 2.6 2.3 2.4 2.4 2.2
3.0 2.2 2.8 2.7 2.4 2.4 2.4 2.2
5.0 4.1 2.8 2.7 2.5 2.4 2.4 2.2
7.0 6.0 2.9 2.7 2.5 2.4 2.4 2.2
9.0 7.9 2.9 2.7 2.5 2.4 2.4 2.2
11.0 9.8 2.9 2.7 2.5 2.4 2.4 2.2
13.0 11.8 2.9 2.7 2.5 2.4 2.4 2.2
15.0 13.7 2.9 2.7 2.5 2.4 2.4 2.2
-19.8 -20.0 2.1 2.1 2.1 2.1 2.1 2.1
-18.8 -19.0 2.2 2.2 2.2 2.2 2.2 2.2
-16.7 -17.0 2.3 2.3 2.3 2.3 2.3 2.3
-14.7 -15.0 2.5 2.4 2.2 2.4 2.4 2.4
-12.6 -13.0 2.6 2.6 2.3 2.6 2.6 2.6
-10.5 -11.0 2.7 2.7 2.4 2.7 2.7 2.7
-9.5 -10.0 2.8 2.8 2.5 2.8 2.8 2.7
-8.5 -9.1 2.8 2.8 2.5 2.8 2.8 2.7
-7.0 -7.6 2.9 2.9 2.6 2.8 2.8 2.8
-5.0 -5.6 3.0 3.0 2.7 3.0 3.0 2.8
-3.0 -3.7 3.2 3.2 2.8 3.1 3.0 2.8
0.0 -0.7 3.4 3.4 3.0 3.1 3.0 2.8
3.0 2.2 3.6 3.4 3.1 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.7 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.7 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.7 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.7 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.7 3.4 3.2 3.1 3.0 2.8
-19.8 -20.0 2.7 2.7 2.7 2.6 2.6 2.6
-18.8 -19.0 2.8 2.8 2.8 2.8 2.7 2.7
-16.7 -17.0 2.9 2.9 2.9 2.9 2.9 2.9
-14.7 -15.0 3.1 3.0 2.7 3.0 3.0 3.0
-12.6 -13.0 3.2 3.2 2.9 3.2 3.2 3.2
-10.5 -11.0 3.4 3.4 3.0 3.4 3.4 3.4
-9.5 -10.0 3.4 3.4 3.1 3.4 3.4 3.4
-8.5 -9.1 3.5 3.5 3.2 3.5 3.5 3.4
-7.0 -7.6 3.6 3.6 3.3 3.6 3.6 3.5
-5.0 -5.6 3.8 3.8 3.4 3.7 3.7 3.5
-3.0 -3.7 4.0 4.0 3.5 3.9 3.8 3.5
0.0 -0.7 4.2 4.2 3.7 3.9 3.8 3.5
3.0 2.2 4.4 4.3 3.9 3.9 3.8 3.5
5.0 4.1 4.5 4.3 4.0 3.9 3.8 3.5
7.0 6.0 4.6 4.3 4.0 3.9 3.8 3.5
9.0 7.9 4.6 4.3 4.0 3.9 3.8 3.5
11.0 9.8 4.6 4.3 4.0 3.9 3.8 3.5
13.0 11.8 4.6 4.3 4.0 3.9 3.8 3.5
15.0 13.7 4.6 4.3 4.0 3.9 3.8 3.5
2.2
2.8
3.6
Notes:
TC: Total Capacity(kW)
Heating Capacity
Indoor unit
ART COOL Gallery
9-8 9-8
A
R
T

C
O
O
L

G
a
l
l
e
r
y
7. Electric Characteristics
Symbols:
MCA: Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor
Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA
MFA 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the MCA.
5. Instead of fuse, use Circuit Breaker.
Units
Model Type Hz Volts Voltage Range
ARNU07GSF*2 SF
Max:264
0.23 15 0.024 0.18 35 35
ARNU09GSF*2 SF 50 220 - 240
Min:198
0.23 15 0.024 0.18 35 35
ARNU12GSF*2 SF 0.23 15 0.024 0.18 35 35
ARNU07GSF*2 SF
Max:242
0.23 15 0.024 0.18 35 35
ARNU09GSF*2 SF 60 220
Min:198
0.23 15 0.024 0.18 35 35
ARNU12GSF*2 SF 0.23 15 0.024 0.18 35 35
Power Supply IFM Input(W)
MCA MFA kW FLA Cooling Heating
Indoor unit
ART COOL Gallery
9-9 9-9
A
R
T

C
O
O
L

G
a
l
l
e
r
y
8. Sound Levels
Overall
Sound Pressure Level
Model
ARNU07GSF*2
ARNU09GSF*2
ARNU12GSF*2
Sound Levels dB(A)
H M L
38 32 27
38 32 27
44 38 32
0.8m
1m
Microphone
Notes:
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.
ARNU07GSF*2
ARNU09GSF*2
ARNU12GSF*2
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
Indoor unit
ART COOL Gallery
9-10 9-10
A
R
T

C
O
O
L

G
a
l
l
e
r
y
9. Installation
Please read the instruction sheets completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
1. Installation guide map
2. Type "A" screw and plastic anchors
Required Parts Required Tools
Four type "A" screws
Connecting cable
Pipes: Gas side
Liquid side
Insulation materials
Additional drain pipe
Level gauge
Screw driver
Electric drill
Hole core drill
Flaring tool set
Specified torque wrenches
Spanner......................................................Half union
A glass of water
Screw driver
Thermometer
Installation Parts Provided
9.1 Selection of the best location
Do not have any heat or steam near the unit.
Select a place where there are no obstacles in front of the unit.
Make sure that condensation drainage can be conveniently
routed away.
Do not install near a doorway.
Ensure that the space around the left and right of the unit is
more than 500mm. The unit should be installed as high on the
wall as possible, allowing a minimum of 200mm from ceiling.
Use a stud finder to locate studs to prevent unnecessary dam-
age to the wall.
More than
200mm
More than
500mm
More than 1500mm
More than
500mm
Indoor unit
ART COOL Gallery
9-11 9-11
A
R
T

C
O
O
L

G
a
l
l
e
r
y
9.2 Preparing Work for Installation
Open panel front
1. Pull the upper part of the front panel.
2. Lift up the panel.
3. To detach the front panel, remove the two screws at the lower part.
4. Detach the front panel from the body.
5. To detach the panel, disconnect the connector at the upper part.
Cover pipe and cover side remove
1. Please remove the screw of the center tuning cover.
2. Pull up the side cover of desired connecting direction, then
cover side is separated.
3. Pick the pipe hole of the side cover.
CAUTION: After removing the pipe hole,
cut the burr for safety.
When making pipe path through rear
wall, you dont need to pick the pipe hole.
NOTICE
Drain hose junction
1. Remove the rubber stopple in the desired drain
direction.
2. Insert drain hose into the handle of drain pan, and
join drain hose and connecting hose according to
the figure by.
Panel Front
Connector
Side cover
Pipe hole
Only the
desired direction
rubber cap
Only the
desired direction
Connecting
part
Adhesive
Drain
hose
Indoor unit
ART COOL Gallery
9-12 9-12
A
R
T

C
O
O
L

G
a
l
l
e
r
y
Plastic anchors
INSTALLATION GUIDE MAP
1
0
m
m
I
N
S
T
A
L
L
A
T
I
O
N

G
U
Plastic anchors
IN
S
T
A
L
L
A
T
IO
N
G
U
ID
E
M
A
P
INSTALLATION GUIDE M
AP
Hanger hole
(Rear side of
the product)
IN
S
TA
IIA
T
IO
N
G
U
ID
E
M
A
P
3. Make a hole with a diameter of 6mm and
depth of 30-35mm by piercing a screw
point.
5. Drive the fore plastic anchors into drilled
points.
7. Hang the hole of product at the upper
screws, and remove the map. (Falling
attention)
9. Check the fixed product with light power.
1. Attach an Installation guide map on the
desired surface.
2. Look at suited horizon by horizontal
meter on the horizontal setting line, and
fix lightly the map by adhesive tape.
4. Drill the pierted part as a diameter of 50mm
for connecting piping. (In case of piercing
rear surface)
6. First, Drive the two points of the upper
parts by screws. (Leave 10mm for hanging
the product)
8. Drive the lower parts after facing the hole
of product with plastic anchors, and fix
completely the upper screws.
10. In case of nothing wrong, connect the
pipe and the wire. (Refer to installation
manual)
Horizontality
IN
S
T
A
L
L
A
T
IO
N
G
U
ID
E
M
A
P
9.3 Fixing Indoor Unit
Indoor unit
ART COOL Gallery
9-13 9-13
A
R
T

C
O
O
L

G
a
l
l
e
r
y
Preparing the indoor unit's piping and drain hose for
installation through the wall.
1. Route the indoor tubing and the drain hose in
the direction of rear left or right
2. Tape the tubing, drain hose and the connecting
cable. Be sure that the drain hose is located at
the lowest side of the bundle. Locating at the
upper side can cause drain pan to overflow
inside the unit.
3. Connecting the pipings to the in door unit and
drain hose to drain pipe
Align the center of the pipings and sufficiently
tighten the flare nut by hand.
Tighten the flare nut with a wrench.
When extending the drain hose at the indoor
unit, install the drain pipe.
4. Wrap the insulation material around the con-
necting portion.
Overlap the connecting pipe insulation material
and the indoor unit pipe insulation material. Bind
them together with vinyl tape so that there is no
gap.
Plastic bands
Insulation material
Vinyl tape(narrow)
Adhesive
Drain pipe
Indoor unit drain hose
Indoor unit tubing Flare nut Pipings
Torque wrench
Indoor unit tubing
Spanner (fixed)
Connection pipe
Flare nut
Drain hose
Connecting
cable
Gas side piping
Liquid side piping
Drain hose
Loop
CAUTION: If the drain hose is routed
inside the room, insulate the hose with
an insulation material* so that dripping
from "sweating"(condensation) will not
damage furniture or floors.
*Foamed polyethylene or equivalent is
recommended.
9.4 Connecting the Piping
Indoor unit
ART COOL Gallery
9-14 9-14
A
R
T

C
O
O
L

G
a
l
l
e
r
y
CAUTION: Installation Information
For right piping. Follow the instruction below.
Good case
Press on the upper side of clamp and unfold the tubing to downward slowly.
Bad case
Following bending type from left to right may cause damage to the turbing.
Downward slope
Do not raise
Accumulated
drain water
Tip of drain hose
dipped in water
Air
Waving
Water
leakage
Water
leakage
Ditch
Less than
50mm gap
Water
leakage
1) To check the drainage.
Pour a glass of water on the evaporator.
Ensure the water flows through the drain hose of
the indoor unit without any leakage and goes out
the drain exit.
2) Drain piping
The drain hose should point downward for easy
drain flow.
Do not make drain piping.
9.5 Drain Piping
Indoor unit
ART COOL Gallery
9-15 9-15
A
R
T

C
O
O
L

G
a
l
l
e
r
y
1. First, Check the side cover assembly
exactly, and fix the power cord in the
bottom groove of cover side left.
2. Assemble connecting lead wire with
controller, fix the upper part of panel
front, and match the lower part of panel
front.
3. Screw up panel front, and suspend the
hook of panel front in the groove.
Panel Front
Connector
9.6 Panel Front Assembly
Indoor unit
ART COOL Gallery
9-16 9-16
A
R
T

C
O
O
L

G
a
l
l
e
r
y
The above circuit diagram is subject to change with-
out notice.
Be sure to connect wires according to the wiring dia-
gram.
Connect the wires firmly, so that not to be pulled out
easily.
Connect the wires according to color codes by refer-
ring the wiring diagram.
CAUTION
9.7 Connect the cable to the Indoor unit.
Connect the cable to the indoor unit by connecting the wires to the terminals on the control board in-
dividually according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit
and the terminal No. are the same as those of the indoor unit.)
The earth wire should be longer than the common wires.
When installing, refer to the circuit diagram on the
Control Box of Indoor Unit.
When installing, refer to the wiring diagram on the
Control Cover Inside Outdoor Unit.
CAUTION
After the confirmation of the above conditions,
prepare the wiring as follows:
1) Never fail to have separate power circuit specif-
ically for the air conditioner. As for the method
of wiring, follow the circuit
diagram posted on the inside of control cover.
2) The screw which fasten the wiring in the casing
of electrical fittings are liable to come loose
from vibrations to which the unit is subjected
during the course of transportation. Check
them and make sure that they are all tightly
fastened. (If they are loose, it could cause
burn-out of the wires.)
3) Confirm the specification of power source.
4) Confirm that electrical capacity is sufficient.
5) See to that the starting voltage is maintained at
more than 90 percent of the rated voltage
marked on the name plate.
6) Confirm that the cable thickness is as specified
in the power source specification.
(Particularly note the relation between cable
length and thickness.
7) Always install an earth leakage circuit breaker
in a wet or moist area.
8) The following would be caused by voltage drop.
Vibration of a magnetic switch, which will damage
the contact point, fuse breaking, disturbance of
the normal function of the overload.
9) The means for disconnection from a power
supply shall be incorporated in the fixed wiring
and have an air gap contact separation of at
least 3mm in each active(phase) conductor.
Terminal Block Indoor
1(L) 2(N) 3 4
INDOOR POWER INPUT
A - - - - - - B A B
GND 12V DRY2 DRY1 INTERNET IDU SODU Outdoor
Unit
Indoor unit
ART COOL Gallery
9-17 9-17
A
R
T

C
O
O
L

G
a
l
l
e
r
y
WIRED REMOTE CONTROLLER INSTALLATION
Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average tempera-
ture.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
Fig.1 Typical locations for remote controller
5feet
(1.5meters)
no
no
no
yes
Remote Controller
TEMP
Remote Controller
TEMP
Remote Controller
TEMP
Indoor unit
ART COOL Gallery
9-18 9-18
A
R
T

C
O
O
L

G
a
l
l
e
r
y
10. Accessories
Name
Quantity
Shape
Type "A" screws and
plastic anchors
Installation guide map
1 EA 4 SET
(Other)
Owner's manual
Installation manual
Standard Accessories
Use only those accessories (Standard or optional) which have designated specifications.
CAUTION
Indoor unit
Ceiling & Floor
Ceiling Suspended
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. Electric Characteristics
8. Sound Levels
9. Installation
10. Accessories
Ceiling & Floor
Ceiling Suspended
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-1 10-1
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
1. List of functions
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Air flow
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Air purifying Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
Installation
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Reliability Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Convenience Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Individual Simple wired remote controller
control Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Special
Zone control
function kit
CTIE
Electro thermostat
1
Manual
Auto
X
O
3 / 4 / 3
X
O
O
-
X
X
O
X
X
X
O
O
O
O
O(Heat recovery)
X
O(Heat pump or Cooling only)
O
O
O
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
X
Accessory
-
-
-
Function Category
ARNU09GVEA2, ARNU12GVEA2
ARNU18GVJA2, ARNU24GVJA2
O : Applied X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-2 10-2
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
2. Specifications
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Fan Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Color
Ceiling & Floor
ARNU09GVEA2 ARNU12GVEA2
2.8 3.6
2,400 3,100
9,600 12,300
3.2 4.0
2,800 3,400
10,900 13,600
- -
900 x 200 x 490 900 x 200 x 490
35.4 x 7.9 x 19.3 35.4 x 7.9 x 19.3
2 x 12 x 20 2 x 12 x 20
0.10 0.10
Cross Flow Fan Cross Flow Fan
27 27
0.15 0.15
7.6 / 6.9 / 6.2 9.2 / 7.6 / 6.9
268 / 243 / 219 325 / 268 / 244
Direct Direct
BLDC BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene
Fuse Fuse
6.35(1/4) 6.35(1/4)
12.7(1/2) 12.7(1/2)
16(5/8) 16(5/8)
13.7(30.2) 13.7(30.2)
36 / 32 / 28 38 / 36 / 30
1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60
EEV EEV
CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Morning fog Morning fog
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-3 10-3
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Fan Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Color
Ceiling Suspended
ARNU18GVJA2 ARNU24GVJA2
5.6 7.1
4,800 6,100
19,100 24,200
6.3 8.0
5,400 6,900
21,500 27,300
Galvanized Steel Plate+Painting Galvanized Steel Plate+Painting
950 x 220 x 650 950 x 220 x 650
37.4 x 8.7 x 25.6 37.4 x 8.7 x 25.6
3 x 14 x 19 3 x 14 x 19
0.23 0.23
Sirocco Fan Sirocco Fan
60 60
0.30 0.30
16.0 / 14.0 /12.0 18.0 / 16.0 / 14.0
565 / 495 / 424 636 / 565 / 495
Direct Direct
BLDC BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene
Fuse Fuse
6.35(1/4) 9.52(3/8)
12.7(1/2) 15.88(5/8)
16(5/8) 16(5/8)
24.6(54.2) 24.6(54.2)
42 / 40 / 37 43 / 41 / 39
1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60
EEV EEV
CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Morning fog Morning fog
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-4 10-4
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
3. Dimensions
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

V
E
C
e
i
l
i
n
g

&

F
l
o
o
r
A
R
N
U
0
9
G
V
E
A
2
A
R
N
U
1
2
G
V
E
A
2
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
S
i
g
n
a
l

r
e
c
e
i
v
e
r

&

O
p
e
r
a
t
i
o
n

i
n
d
i
c
a
t
o
r
<
C
e
i
l
i
n
g

I
n
s
t
a
l
l
a
t
i
o
n
>
<
F
l
o
o
r

I
n
s
t
a
l
l
a
t
i
o
n
>
A
i
r

s
u
c
t
i
o
n

g
r
i
l
l
A
i
r

d
i
s
c
h
a
r
g
e

g
r
i
l
l
W
M
o
d
e
l
A
R
N
U
0
9
G
V
E
A
2
A
R
N
U
1
2
G
V
E
A
2
H
D
9
0
0
4
9
0
2
0
0
(
u
n
i
t

:

m
m
)
5
8
7
8
7
9
2 4
9
0
0
2
0
0
4 9 0
2 7 3
N
a
m
e



1
A
i
r

d
i
s
c
h
a
r
g
e

g
r
i
l
l




2
A
i
r

s
u
c
t
i
o
n

g
r
i
l
l

N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
(
u
n
i
t

:

m
m
)
2
1
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-5 10-5
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

V
J
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
A
R
N
U
1
8
G
V
J
A
2
A
R
N
U
2
4
G
V
J
A
2
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
4
1
8
0
0
9
5
0
2
2
0
6 5 0
(
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d

t
y
p
e
)
W
M
o
d
e
l
A
R
N
U
1
8
G
V
J
A
2
A
R
N
U
2
4
G
V
J
A
2
H
D
9
5
0
6
5
0
2
2
0
(
u
n
i
t

:

m
m
)
2
1
N
a
m
e



1
A
i
r

d
i
s
c
h
a
r
g
e

g
r
i
l
l




2
A
i
r

s
u
c
t
i
o
n

g
r
i
l
l

N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
(
u
n
i
t

:

m
m
)
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-6 10-6
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
4. Piping Diagrams
Heat Exchanger
C.F.F.
lndoor unit
EEV
:Heating
:Cooling
Filter
Filter
Heat Exchanger
Sirocco Fan
lndoor unit
EEV
:Heating
:Cooling
Filter
Th1
Th1
Th3
Th3
Th2
Th2
Filter
Refrigerant pipe connection port diameter
Model
ARNU09GVEA2 12.7(1/2) 6.35(1/4)
ARNU12GVEA2 12.7(1/2) 6.35(1/4)
ARNU18GVJA2 12.7(1/2) 6.35(1/4)
ARNU24GVJA2 15.88(5/8) 9.52(3/8)
Gas Liquid
[Unit: mm(inch)]
VE Chassis
VJ Chassis
LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-7 10-7
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
5. Wiring Diagrams
CONNECTOR
SPEC. DESCRIPTION
NUMBER
CN-POWER AC power supply AC power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-ROOM Room sensor Room thermistor
CN-REMO Remote controller Remote control line
CN-FLOAT Float switch input Float switch sensing
CN-EEV EEV output EEV Control output
CN-OPTION Option pwb. Communication between main and option
CN-COM Communication Communication between indoor and outdoor
CN-D/PUMP Drain pump output AC Output for drain pump
CN-POWER AC power supply AC Power line input for indoor controller
CN-DISPLAY Display wire Display wire line
CN-DOOR Door lock switch Door lock switch line
CN-CC Dry contact Dry contact line
VE Chassis
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor
CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-8 10-8
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
VJ Chassis
CONNECTOR
SPEC. DESCRIPTION
NUMBER
CN-POWER AC power supply AC power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-ROOM Room sensor Room thermistor
CN-REMO Remote controller Remote control line
CN-FLOAT Float switch input Float switch sensing
CN-EEV EEV output EEV Control output
CN-OPTION Option pwb. Communication between main and option
CN-COM Communication Communication between indoor and outdoor
CN-D/PUMP Drain pump output AC Output for drain pump
CN-POWER AC power supply AC Power line input for indoor controller
CN-DISPLAY Display wire Display wire line
CN-DOOR Door lock switch Door lock switch line
CN-CC Dry contact Dry contact line
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor
CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-9 10-9
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
6. Capacity Tables
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
6.1 Cooling Capacity
Cooling capacity
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.4 4.3
12 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.3 4.2
14 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.2 4.2
16 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.1 4.1
18 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.0 4.1
20 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.9 4.0
21 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.8 4.0
23 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.7 3.9
25 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.6 4.3 6.6 3.9
27 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.4 4.2 6.6 3.8
29 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.4 4.1 6.5 3.8
31 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.3 4.1 6.4 3.7
33 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.2 4.0 6.3 3.7
35 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.0 3.9 6.2 3.6
37 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 5.8 4.1 5.9 3.8 6.1 3.6
39 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 5.7 4.0 5.8 3.8 6.0 3.5
3.6
5.6
10 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.7 2.1
12 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.6 2.1
14 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.6 2.1
16 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.5 2.0
18 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.5 2.0
20 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 2.0
21 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 2.0
23 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 1.9
25 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.3 2.1 3.3 1.9
27 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 2.1 3.3 1.9
29 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 2.0 3.2 1.9
31 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.1 2.0 3.2 1.8
33 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.1 2.0 3.1 1.8
35 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.0 1.9 3.1 1.8
37 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 3.0 1.9 3.0 1.8
39 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 2.9 1.9 3.0 1.7
10 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.7 2.7
12 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.7 2.7
14 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.6 2.7
16 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.6 2.6
18 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.5 2.6
20 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.4 2.5
21 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.4 2.5
23 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.3 2.5
25 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.2 2.7 4.3 2.5
27 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.1 2.6 4.2 2.4
29 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.1 2.6 4.2 2.4
31 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.0 2.6 4.1 2.4
33 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.0 2.5 4.0 2.3
35 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 3.9 2.5 4.0 2.3
37 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.7 2.6 3.8 2.4 3.9 2.3
39 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.7 2.5 3.7 2.4 3.8 2.2
2.8
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-10 10-10
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
Cooling capacity
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.3 5.4
12 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.2 5.4
14 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.1 5.3
16 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.0 5.2
18 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.8 5.2
20 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.7 5.1
21 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.7 5.1
23 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.5 5.0
25 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.4 5.4 8.4 4.9
27 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.2 5.3 8.3 4.9
29 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.1 5.2 8.2 4.8
31 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.0 5.1 8.1 4.7
33 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 7.8 5.1 7.9 4.6
35 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 7.7 5.0 7.8 4.6
37 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.4 5.1 7.5 4.9 7.7 4.5
39 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.2 5.0 7.4 4.8 7.6 4.4
7.1
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-11 10-11
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
6.2 Heating Capacity
Notes:
TC: Total Capacity(kW)
Heating capacity
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 2.1 2.1 2.1 2.1 2.1 2.1
-18.8 -19.0 2.2 2.2 2.2 2.2 2.2 2.2
-16.7 -17.0 2.3 2.3 2.3 2.3 2.3 2.3
-14.7 -15.0 2.5 2.4 2.2 2.4 2.4 2.4
-12.6 -13.0 2.6 2.6 2.3 2.6 2.6 2.6
-10.5 -11.0 2.7 2.7 2.4 2.7 2.7 2.7
-9.5 -10.0 2.8 2.8 2.5 2.8 2.8 2.7
-8.5 -9.1 2.8 2.8 2.5 2.8 2.8 2.7
-7.0 -7.6 2.9 2.9 2.6 2.8 2.8 2.8
-5.0 -5.6 3.0 3.0 2.7 3.0 3.0 2.8
-3.0 -3.7 3.2 3.2 2.8 3.1 3.0 2.8
0.0 -0.7 3.4 3.4 3.0 3.1 3.0 2.8
3.0 2.2 3.6 3.4 3.1 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.7 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.7 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.7 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.7 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.7 3.4 3.2 3.1 3.0 2.8
-19.8 -20.0 2.7 2.7 2.7 2.6 2.6 2.6
-18.8 -19.0 2.8 2.8 2.8 2.8 2.7 2.7
-16.7 -17.0 2.9 2.9 2.9 2.9 2.9 2.9
-14.7 -15.0 3.1 3.0 2.7 3.0 3.0 3.0
-12.6 -13.0 3.2 3.2 2.9 3.2 3.2 3.2
-10.5 -11.0 3.4 3.4 3.0 3.4 3.4 3.4
-9.5 -10.0 3.4 3.4 3.1 3.4 3.4 3.4
-8.5 -9.1 3.5 3.5 3.2 3.5 3.5 3.4
-7.0 -7.6 3.6 3.6 3.3 3.6 3.6 3.5
-5.0 -5.6 3.8 3.8 3.4 3.7 3.7 3.5
-3.0 -3.7 4.0 4.0 3.5 3.9 3.8 3.5
0.0 -0.7 4.2 4.2 3.7 3.9 3.8 3.5
3.0 2.2 4.4 4.3 3.9 3.9 3.8 3.5
5.0 4.1 4.5 4.3 4.0 3.9 3.8 3.5
7.0 6.0 4.6 4.3 4.0 3.9 3.8 3.5
9.0 7.9 4.6 4.3 4.0 3.9 3.8 3.5
11.0 9.8 4.6 4.3 4.0 3.9 3.8 3.5
13.0 11.8 4.6 4.3 4.0 3.9 3.8 3.5
15.0 13.7 4.6 4.3 4.0 3.9 3.8 3.5
-19.8 -20.0 4.2 4.2 4.2 4.2 4.2 4.2
-18.8 -19.0 4.3 4.3 4.3 4.3 4.3 4.3
-16.7 -17.0 4.6 4.6 4.6 4.6 4.6 4.5
-14.7 -15.0 4.9 4.8 4.3 4.8 4.8 4.8
-12.6 -13.0 5.1 5.1 4.5 5.0 5.0 5.0
-10.5 -11.0 5.4 5.4 4.8 5.4 5.3 5.3
-9.5 -10.0 5.4 5.4 4.9 5.4 5.4 5.4
-8.5 -9.1 5.5 5.5 5.0 5.5 5.5 5.4
-7.0 -7.6 5.7 5.7 5.1 5.6 5.6 5.5
-5.0 -5.6 6.0 6.0 5.4 5.8 5.8 5.5
-3.0 -3.7 6.2 6.2 5.5 6.1 5.9 5.5
0.0 -0.7 6.6 6.6 5.8 6.1 5.9 5.5
3.0 2.2 7.0 6.7 6.2 6.1 5.9 5.5
5.0 4.1 7.1 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.2 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.2 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.2 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.2 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.2 6.7 6.3 6.1 5.9 5.5
2.8
3.6
5.6
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-12 10-12
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
Notes:
TC: Total Capacity(kW)
Heating capacity
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 5.4 5.4 5.4 5.3 5.3 5.3
-18.8 -19.0 5.5 5.5 5.5 5.5 5.4 5.4
-16.7 -17.0 5.8 5.8 5.8 5.8 5.8 5.8
-14.7 -15.0 6.2 6.1 5.5 6.1 6.1 6.1
-12.6 -13.0 6.5 6.5 5.8 6.4 6.4 6.4
-10.5 -11.0 6.8 6.8 6.0 6.8 6.7 6.7
-9.5 -10.0 6.9 6.9 6.2 6.9 6.9 6.8
-8.5 -9.1 7.0 7.0 6.3 7.0 7.0 6.8
-7.0 -7.6 7.3 7.3 6.5 7.1 7.1 7.0
-5.0 -5.6 7.6 7.6 6.8 7.4 7.4 7.0
-3.0 -3.7 7.9 7.9 7.0 7.7 7.5 7.0
0.0 -0.7 8.4 8.4 7.4 7.8 7.5 7.0
3.0 2.2 8.9 8.6 7.8 7.8 7.5 7.0
5.0 4.1 9.0 8.6 8.0 7.8 7.5 7.0
7.0 6.0 9.2 8.6 8.0 7.8 7.5 7.0
9.0 7.9 9.2 8.6 8.0 7.8 7.5 7.0
11.0 9.8 9.2 8.6 8.0 7.8 7.5 7.0
13.0 11.8 9.2 8.6 8.0 7.8 7.5 7.0
15.0 13.7 9.2 8.6 8.0 7.8 7.5 7.0
7.1
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-13 10-13
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
7. Electric Characteristics
Symbols:
MCA: Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor
Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA
MFA 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the MCA.
5. Instead of fuse, use Circuit Breaker.
Units
Model Type Hz Volts Voltage Range
ARNU09GVEA2 VE 0.22 15 0.027 0.17 30 30
ARNU12GVEA2 VE
50 220 - 240
Max:264 0.22 15 0.027 0.17 30 30
ARNU18GVJA2 VJ Min:198 0.43 15 0.060 0.35 63 63
ARNU24GVJA2 VJ 0.43 15 0.060 0.35 63 63
ARNU09GVEA2 VE 0.22 15 0.027 0.17 30 30
ARNU12GVEA2 VE
60 220
Max:242 0.22 15 0.027 0.17 30 30
ARNU18GVJA2 VJ Min:198 0.43 15 0.060 0.35 63 63
ARNU24GVJA2 VJ 0.43 15 0.060 0.35 63 63
Power Supply IFM Input(W)
MCA MFA kW FLA Cooling Heating
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-14 10-14
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
8. Sound Levels
Overall
Sound Pressure Level
Model
ARNU09GVEA2
ARNU12GVEA2
36
38
32
36
28
30
Sound Levels dB(A)
H M L
1m
Microphone
1
m
Notes:
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.
Model
ARNU18GVJA2
ARNU24GVJA2
42
43
40
41
37
39
Sound Levels dB(A)
H M L
ARNU09GVEA2 ARNU12GVEA2
ARNU24GVJA2
ARNU18GVJA2
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-15 10-15
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
9. Installation
Please read this instruction sheet completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
9.1 Features
9.1.1 VE Chassis
Air filters
(behind front panel)
Air outlet vent
Vertical louver Horizontal louver
Air inlet vent
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-16 10-16
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
9.1.2 VJ Chassis
Signal Receptor
Drain hose
Air Filter
Air Discharge
Right Side Cover
Inlet Grill
Left Side Cover
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-17 10-17
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
9.2 Installation Map
Installation parts you should purchase. NOTICE
(Left and right
are identical)
(Left and right
are identical)
Sleeve
Bushing-Sleeve
Putty(Gum Type Sealer)
Bend the pipe as closely
on the wall as possible,
but be careful that it
doesn't break.
Vinyl tape (Wide)
To carry out the drainage
test, remove the air filters
and pour water into the heat
exchanger.
Apply after carrying out a
drainage test.
Saddle
There should be no gap between
the ceiling and the unit.
More than
200mm
More than
200mm
More than 50mm
More than 50mm
Ceiling Mounting
Wall Mounting
VE Chassis
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-18 10-18
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
9.3 Select the best Location
9.4 Preparing Work for Installation
Indoor unit
1. Do not have any heat or steam near the unit.
2. Select a place where there are no obstacles in front
of the unit.
3. Make sure that condensation drainage can be conve-
niently routed away.
4. Do not install near a doorway.
5. Ensure that the interval between a wall and the left
(or right) of the unit is more than 200mm. The unit
should be installed as low as possible on the wall,
allowing a minimum of 500mm from floor.
6. Use a stud finder to locate studs to prevent unneces-
sary damage to the wall.
More than 200mm
More than 50mm
More than 200mm
More than 200mm
More than 50mm
More than 200mm
Open panel front
1. Remove the five screws.
2. Release the claws in the 3 places indicated.
3. Pull up the Front Panel.
Cover pipe and cover side remove
1. Pull up the side cover of desired connecting direction,
then cover side is separated.
2. Pick the pipe hole of the side cover.
CAUTION: After removing the pipe
hole, cut the burr for safety.
When making pipe path through rear
wall, you dont need to pick the pipe hole.
Drain hose junction
1. Remove the rubber stopple in the desired drain direc-
tion.
2. Insert drain hose into the handle of drain pan, and
join drain hose and connecting hose according to the
figure as shown on the right.
NOTICE
2
1
3
Claw
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-19 10-19
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
9.5 Mounting the installation plate(Wall Mounting)
The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. While mounting the unit on a con-
crete wall, use anchor bolts.
Mount the installation plate horizontally by aligning
the centerline using a level.
2. Measure the wall and mark the centerline. It is also
important to use caution concerning the location of
the installation plate-routing of the wiring to power
outlets is through the walls typically. Drilling the
hole through the wall for piping connections must
be done safely.
Installation Plate
Type "A" screw
Installation plate
70mm
Left rear piping Right rear piping
Floor
70
120
70
more than 2000
70mm
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-20 10-20
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
9.6 Mounting the anchor Nut & Bolt(Ceiling Mounting)
Prepare 4 suspension bolts. (Each bolts length
should be same.)
Measure and mark the position for the Suspension
bolts and the piping hole.
Drill the hole for anchor nut on the ceiling.
Insert the nuts and washer onto the suspension
bolts for locking the suspension bolts on the ceiling.
Mount the suspension bolts to the anchor-nuts firmly.
Secure the hangers onto the Suspension bolts
(adjust level roughly.) using nuts, washers and spring
washers.
Adjust a level with a level gauge on the direction of
left-right, back-forth by adjusting suspension bolts.
Adjust a level on the direction of top-bottom by
adjusting supension bolts. Then the unit will be
inclined to the bottomside so as to drain well.
Suspension bolt
piping hole
(45)
235
50
100
820
40
Washer Nut
Suspension
bolts
Ceiling
Anchor nut
Reference
of piping
hole (45)
Suspension
bolts
Spring
washer
Max.
12mm
Hangen
Washer
Nut
Flat washer for M10
(accessory)
Flat washer for M10
(accessory)
Hanging bolt
(W3/8 or M10)
Nut
(W3/8 or M10)
Nut
(W3/8 or M10)
: Tighten the nut and bolt to prevent unit falling.
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-21 10-21
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
: Installation Information For right piping. Follow the instruction below.
Good case
For left piping. Follow the instruction below.
1. Press on the upper side of clamp. ( )
2. Unfold the tubing downward slowly. ( )
3. Bend the tubing to the left side of chassis.
Bad case
1. Following bending type from right to
left could cause problem of pipe damage.
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-22 10-22
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
9.7 Checking the Drainage
9.8 Panel Front Assembly
1. Set the air direction louvers up-and-down to the posi-
tion(horizontally) by hand.
To check the drainage.
1. Pour a glass of water on the evaporator using a ket-
tle.
2. Ensure the water flows through the drain hose of the
indoor unit without any leakage and goes out the
drain exit.
I Checking the Drainage
1. Remove the Air Filter.
To remove air filter, take hold of tab and pull slightly
upwards.
2. Check the drainage.
Spray one or two glasses of water upon the evapo-
rator.
Ensure that water flows drain hose of indoor unit
without any leakage.
Drain piping
1. The drain hose should point downward for easy drain
flow.
2. Do not make drain piping like the following.
Downward slope
Do not raise
Accumulated
drain water
Tip of drain hose
dipped in water
Air
Waving
Water
leakage
Water
leakage
Ditch
Less than
50mm gap
Water
leakage
1. Suspend the hook of panel front in the groove.
2. Press the panel front.
3. Screw up panel front.
1
2
3
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-23 10-23
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
VJ Chassis
9.9 Select the best Location
Indoor unit
1. Do not have any heat or steam near the unit.
2. Select a place where there are no obstacles in
front of the unit.
3. Make sure that condensation drainage can be
conveniently routed away.
4. Do not install near a doorway.
5. Ensure that the interval between a wall and the
left (or right) of the unit is more than 700mm.
6. Use a stud finder to locate studs to prevent
unnecessary damage to the wall.
More than
700mm
More than
300mm
More than
700mm
: In case that the unit is installed near the sea, the installation parts may be cor-
roded by salt. The installation parts (and the unit) should be treated with appropriate anti-corro-
sion measures.
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-24 10-24
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
9.10 Preparing Work for Installation
Open side cover
1. Remove two screws from side-cover as shown in
fig.
2. Unlock side-cover from side panel by slightly
pulling the edge of side cover.
3. Tap the side-cover with your palm on the back-
side.(Inlet grill side.)
4. Hold the side-cover with other hand while tap-
ping to prevent it to fall down.
5. Remove the rubber stopple in the desired drain
direction.
6. Knock out the pipe hole from the left side-cover
with the help or nipper/plier.
7. Knock hole on right side-cover only if right side
is selected for water drain.
2
1
Edge part
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-25 10-25
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
MOUNTING THE ANCHOR NUT AND
BOLT
Prepare 4 suspension bolts. (Each bolts length
should be same.)
Measure and mark the position for the
Suspension bolts and the piping hole.
Drill the hole for anchor nut on the ceiling.
Insert the nuts and washer onto the suspension
bolts for locking the suspension bolts on the ceil-
ing.
Mount the suspension bolts to the anchor-nuts
firmly.
Secure the hangers onto the Suspension bolts
(adjust level roughly.) using nuts, washers and
spring washers.
Adjust a level with a level gauge on the direction
of left-right, back-forth by adjusting suspension
bolts.
Adjust a level on the direction of top-bottom by
adjusting supension bolts. Then the unit will be
inclined to the bottomside so as to drain well.
Flat washer for M10
(accessory)
Flat washer for M10
(accessory)
Hanging bolt
(W3/8 or M10)
Nut
(W3/8 or M10)
Nut
(W3/8 or M10)
5
-
7
m
m
(
3
/
1
6
"
~
5
/
1
6
"
)
Indoor
WALL
Outdoor
Suspension bolt
B A
Washer Nut
Suspension
bolts
Ceiling
Anchor nut
Suspension
bolts
Spring
washer
Max.
12mm
Hangen
Washer
Nut
: Tighten the nut and bolt to prevent unit falling.
DRILL A HOLE IN THE WALL.
Drill the piping hole with a 70mm hole core drill.
Drill the piping hole at either the right or the left
with the hole slightly slanted to the outdoor side.
VJ 855 320
DIM.
MODEL
A B
(Unit: mm)
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-26 10-26
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
9.11 Indoor unit installation
Hang the Indoor unit on suspension bolt as per following guidelines:
1. Lift the indoor unit to sufficient height.
2. Insert the suspended part of four suspension bolt in the four hangers provided on the side of main body one by one.
3. Lower the indoor unit till the hangers rest on their respective flat washer.
4. Adjust the level in the top down direction by adjusting the suspension bolts.
Inclined the indoor unit as per direction provided in the fig
Ceiling
Ceiling
10~20mm
1. Inclination of the indoor unit is very important for drain purposes in the convertible
type air conditioner.
2. Minimum thickness of the insulation for the connecting pipe shall be 10mm.
3. If the Installation Plates are fixed to horizontal line, the indoor unit after installing will be
declined to the bottomside.
Front of view
The unit must be horizontal or inclined at angle.
The inclination should be less than or equal to 1 or in between 10 to 20mm inclined in drain direction as
shown in fig.
The unit must be inclined to the bottomside of the unit when finished installation.
Side of view
: Installation Information For Declination
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-27 10-27
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
9.12 Checking the Drainage
1. Set the air direction louvers up-and-down to the posi-
tion(horizontally) by hand.
To check the drainage.
1. Pour a glass of water on the evaporator using a ket-
tle.
2. Ensure the water flows through the drain hose of the
indoor unit without any leakage and goes out the
drain exit.
Drain piping
1. The drain hose should point downward for easy drain
flow.
2. Do not make drain piping like the following.
Downward slope
Do not raise
Accumulated
drain water
Tip of drain hose
dipped in water
Air
Waving
Water
leakage
Water
leakage
Ditch
Less than
50mm gap
Water
leakage
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-28 10-28
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
9.13 Wiring Connection
Connect the wires to the terminals on the control board individually according to the outdoor unit con-
nection.
Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of
indoor unit respectively.
Terminal Block Indoor
1(L) 2(N) 3 4
INDOOR POWER INPUT
A - - - - - - B A B
GND 12V DRY2 DRY1 INTERNET IDU SODU Outdoor
Unit
WARNING : Make sure that the screws of the terminal are free from looseness.
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-29 10-29
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
CAUTION:
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have a separate power circuit specially for the air conditioner. As for the method of
wiring, follow the circuit diagram posted on the inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screws which fasten the wiring in the casing of electrical fittings are liable to come loose
from vibrations to which the unit is subjected during the course of transportation. Check them
and make sure that they are all tightly fastened. (If they are loose, it could give rise to burn-out of
the wires.)
4) Specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage
marked on the name plate.
7) Confirm that the cable thickness is as specified in the power sources specification. (Particularly
note the relation between cable length and thickness.)
8) Never fail to equip a leakage breaker where it is wet or moist.
9) The following troubles would be caused by voltage drop-down.
Vibration of a magnetic switch, damage on the contact point, fuse breaking, disturbance by the normal
function of an overload protection device.
Proper starting power is not given to the compressor.
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-30 10-30
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
WIRED REMOTE CONTROLLER INSTALLATION
Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average tempera-
ture.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
Fig.1 Typical locations for remote controller
5feet
(1.5meters)
no
no
no
yes
Remote Controller
TEMP
Remote Controller
TEMP
Remote Controller
TEMP
Indoor unit
Ceiling & Floor
Ceiling Suspended
10-31 10-31
C
e
i
l
i
n
g

&

F
l
o
o
r
/
C
e
i
l
i
n
g

S
u
s
p
e
n
d
e
d
10. Accessories
Standard Accessories
Type "A" screw and
plastic anchor
4EA 1EA
Installation plate
Name
Quantity
Shape
(Other)
Owner's manual
Installation manual
Use only those accessories (Standard or optional) which have designated specifications.
CAUTION
Indoor unit
Floor Standing
F
l
o
o
r

S
t
a
n
d
i
n
g
1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. Air Velocity and Temperature Distribution
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories
Floor Standing
Indoor unit
Floor Standing
11-1 11-1
F
l
o
o
r

S
t
a
n
d
i
n
g
1. List of functions
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Air flow
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Air purifying Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
Installation
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Reliability Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Convenience Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Individual Simple wired remote controller
control Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Special
Zone control
function kit
CTIE
Electro thermostat
1
-
-
-
-
3 / 3 / 3
-
-
-
-
X
X
O
X
O
X
-
O
O
O
O(Heat recovery)
X
O(Heat pump or Cooling only)
O
O
-
O
X
O
O
O
Accessory
Accessory
Accessory
Accessory
X
Accessory
-
-
-
Function Category
ARNU07GCEA2, ARNU09GCEA2, ARNU12GCEA2
ARNU15GCEA2, ARNU18GCFA2, ARNU24GCFA2
ARNU07GCEU2, ARNU09GCEU2, ARNU12GCEU2
ARNU15GCEU2, ARNU18GCFU2, ARNU24GCFU2
O : Applied X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.
Indoor unit
Floor Standing
11-2 11-2
F
l
o
o
r

S
t
a
n
d
i
n
g
2. Specification
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Fan Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Floor Standing
ARNU07GCEA2 ARNU09GCEA2 ARNU12GCEA2
2.2 2.8 3.6
1,900 2,400 3,100
7,500 9,600 12,300
2.5 3.2 4.0
2,200 2,800 3,400
8,500 10,900 13,600
Galvanized Galvanized Galvanized
Steel Plate Steel Plate Steel Plate
1,067 x 203 x 635 1,067 x 203 x 635 1,067 x 203 x 635
42.2 x 8.0 x 25.0 42.2 x 8.0 x 25.0 42.2 x 8.0 x 25.0
2 x 12 x 19 2 x 12 x 19 2 x 12 x 19
0.16 0.16 0.16
Sirocco Fan Sirocco Fan Sirocco Fan
28 28 28
0.15 0.15 0.15
8.5 / 7.5 / 6.5 9.5 / 8.5 / 7.5 10.5 / 9.5 / 8.5
300 / 265 / 229 335 / 300 / 265 371 / 335 / 300
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Microprocessor, Microprocessor,
Thermostat for Thermostat for Thermostat for
cooling and heating cooling and heating cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene
Resin Net(washable) Resin Net(washable) Resin Net(washable)
Fuse Fuse Fuse
6.35(1/4) 6.35(1/4) 6.35(1/4)
12.7(1/2) 12.7(1/2) 12.7(1/2)
12(15/32) 12(15/32) 12(15/32)
27(59.5) 27(59.5) 27(59.5)
35 / 33 / 31 36 / 34 / 32 37 / 35 / 33
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Indoor unit
Floor Standing
11-3 11-3
F
l
o
o
r

S
t
a
n
d
i
n
g
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Fan Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Floor Standing
ARNU07GCEU2 ARNU09GCEU2 ARNU12GCEU2
2.2 2.8 3.6
1,900 2,400 3,100
7,500 9,600 12,300
2.5 3.2 4.0
2,200 2,800 3,400
8,500 10,900 13,600
Galvanized Galvanized Galvanized
Steel Plate Steel Plate Steel Plate
978 x 190 x 639 978 x 190 x 639 978 x 190 x 639
38.5 x 7.5 x 25.2 38.5 x 7.5 x 25.2 38.5 x 7.5 x 25.2
2 x 12 x 19 2 x 12 x 19 2 x 12 x 19
0.16 0.16 0.16
Sirocco Fan Sirocco Fan Sirocco Fan
28 28 28
0.15 0.15 0.15
8.5 / 7.5 / 6.5 9.5 / 8.5 / 7.5 10.5 / 9.5 / 8.5
300 / 265 / 229 335 / 300 / 265 371 / 335 / 300
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Microprocessor, Microprocessor,
Thermostat for Thermostat for Thermostat for
cooling and heating cooling and heating cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene
Resin Net(washable) Resin Net(washable) Resin Net(washable)
Fuse Fuse Fuse
6.35(1/4) 6.35(1/4) 6.35(1/4)
12.7(1/2) 12.7(1/2) 12.7(1/2)
12(15/32) 12(15/32) 12(15/32)
20(44.1) 20(44.1) 20(44.1)
35 / 33 / 31 36 / 34 / 32 37 / 35 / 33
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Indoor unit
Floor Standing
11-4 11-4
F
l
o
o
r

S
t
a
n
d
i
n
g
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Fan Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Floor Standing
ARNU15GCEA2 ARNU18GCFA2 ARNU24GCFA2
4.5 5.6 7.1
3,900 4,800 6,100
15,400 19,100 24,200
5.0 6.3 8.0
4,300 5,400 6,900
17,100 21,500 27,300
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
1,067 x 203 x 635 1,345 x 203 x 635 1,345 x 203 x 635
42.2 x 8.0 x 25.0 52.9 x 8.0 x 25.0 52.9 x 8.0 x 25.0
2 x 12 x 19 3 x 11 x 19 3 x 11 x 19
0.16 0.23 0.23
Sirocco Fan Sirocco Fan Sirocco Fan
28 76 76
0.15 0.38 0.38
11.5 / 10.0 / 9.5 16.0 / 14.0 / 12.0 18.0 / 16.0 / 14.0
406 / 353 / 335 565 / 494 / 424 635 / 565 / 494
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Thermostat Microprocessor, Thermostat Microprocessor, Thermostat
for cooling and heating for cooling and heating for cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene
Resin Net(washable) Resin Net(washable) Resin Net(washable)
Fuse Fuse Fuse
6.35(1/4) 6.35(1/4) 9.52(3/8)
12.7(1/2) 12.7(1/2) 15.88(5/8)
12(15/32) 12(15/32) 12(15/32)
27(59.5) 34(75.0) 34(75.0)
38 / 37 / 35 40 / 37 / 34 43 / 40 / 37
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Indoor unit
Floor Standing
11-5 11-5
F
l
o
o
r

S
t
a
n
d
i
n
g
Notes:-
1. Capacities are based on the following conditions:
Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Type
Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Dimensions(WxDxH)
Body
mm
inch
Coil
Rows x Columns x FPI
Face Area m
2
Type
Motor Output x Number W
Running Current A
Fan Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side mm(inch)
Pipe Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight kg(lbs)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A)
Power Supply , V, Hz
Refrigerant Control
Power cable mm
2
Transmission cable mm
2
Floor Standing
ARNU15GCEU2 ARNU18GCFU2 ARNU24GCFU2
4.5 5.6 7.1
3,900 4,800 6,100
15,400 19,100 24,200
5.0 6.3 8.0
4,300 5,400 6,900
17,100 21,500 27,300
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
978 x 190 x 639 1,256 x 190 x 639 1,256 x 190 x 639
38.5 x 7.5 x 25.2 49.5 x 7.5 x 25.2 49.5 x 7.5 x 25.2
2 x 12 x 19 3 x 11 x 19 3 x 11 x 19
0.16 0.23 0.23
Sirocco Fan Sirocco Fan Sirocco Fan
28 76 76
0.15 0.38 0.38
11.5 / 10.0 / 9.5 16.0 / 14.0 / 12.0 18.0 / 16.0 / 14.0
406 / 353 / 335 565 / 494 / 424 635 / 565 / 494
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Thermostat Microprocessor, Thermostat Microprocessor, Thermostat
for cooling and heating for cooling and heating for cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene
Resin Net(washable) Resin Net(washable) Resin Net(washable)
Fuse Fuse Fuse
6.35(1/4) 6.35(1/4) 9.52(3/8)
12.7(1/2) 12.7(1/2) 15.88(5/8)
12(15/32) 12(15/32) 12(15/32)
20(44.1) 27(59.5) 27(59.5)
38 / 37 / 35 40 / 37 / 34 43 / 40 / 37
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
Indoor unit
Floor Standing
11-6 11-6
F
l
o
o
r

S
t
a
n
d
i
n
g
3. Dimensions
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

C
E
F
l
o
o
r

S
t
a
n
d
i
n
g
A
R
N
U
0
7
G
C
E
A
2
A
R
N
U
0
9
G
C
E
A
2
A
R
N
U
1
2
G
C
E
A
2
A
R
N
U
1
5
G
C
E
A
2
A
R
N
U
0
7
G
C
E
U
2
A
R
N
U
0
9
G
C
E
U
2
A
R
N
U
1
2
G
C
E
U
2
A
R
N
U
1
5
G
C
E
U
2
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
<
W
i
t
h

C
a
s
e
>
<
W
i
t
h
o
u
t

C
a
s
e
>
1
0
6
7
1
0
6
7
1
4
8
.
3
1
4
8
.
3
4 9
7 0
6 3 5
2
0
3
9
7
8
7
9
4
6 3 9
1
3
2 0 . 4
6 2 . 8
1
9
0
1
6
1
1
4
W
M
o
d
e
l
A
R
N
U
0
7
G
C
E
A
2
A
R
N
U
0
9
G
C
E
A
2
A
R
N
U
1
2
G
C
E
A
2
A
R
N
U
1
5
G
C
E
A
2
H
D
1
0
6
7
6
3
5
2
0
3
A
R
N
U
0
7
G
C
E
U
2
A
R
N
U
0
9
G
C
E
U
2
A
R
N
U
1
2
G
C
E
U
2
A
R
N
U
1
5
G
C
E
U
2
9
7
8
6
3
9
1
9
0
(
u
n
i
t

:

m
m
)
N
a
m
e



1
A
i
r

d
i
s
c
h
a
r
g
e

g
r
i
l
l




2
A
i
r

s
u
c
t
i
o
n

g
r
i
l
l

N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
(
u
n
i
t

:

m
m
)
1
2
Indoor unit
Floor Standing
11-7 11-7
F
l
o
o
r

S
t
a
n
d
i
n
g
7
6
,

S
e
o
n
g
s
a
n
-
d
o
n
g
,

C
h
a
n
g
w
o
n

C
i
t
y
,

G
y
e
o
n
g
n
a
m
,
6
4
1
-
7
1
3
,

K
o
r
e
a
C
H
A
S
S
I
S

C
O
D
E
:

C
F
F
l
o
o
r

S
t
a
n
d
i
n
g
A
R
N
U
1
8
G
C
F
A
2
A
R
N
U
2
4
G
C
F
A
2
A
R
N
U
1
8
G
C
F
U
2
A
R
N
U
2
4
G
C
F
U
2
N
o
t
e
1
.

U
n
i
t

s
h
o
u
l
d

b
e

i
n
s
t
a
l
l
e
d

i
n

c
o
m
p
l
i
a
n
c
e

w
i
t
h

t
h
e

i
n
s
t
a
l
l
a
t
i
o
n

m
a
n
u
a
l





i
n

t
h
e

p
r
o
d
u
c
t

b
o
x
.
2
.

U
n
i
t

s
h
a
l
l

b
e

g
r
o
u
n
d
e
d

i
n

a
c
c
o
r
d
a
n
c
e

w
i
t
h

t
h
e

l
o
c
a
l

r
e
g
u
l
a
t
i
o
n
s

o
r





a
p
p
l
i
c
a
b
l
e

n
a
t
i
o
n
a
l

c
o
d
e
s
.
<
W
i
t
h

C
a
s
e
>
<
W
i
t
h
o
u
t

C
a
s
e
>
2 0 3
1
3
4
5
6 3 5
7 0
1
4
8
.
3
1
0
4
8
.
4
4 9 . 4
1
4
8
.
3
1
9
0
1
6
1
1
4
1
2
5
6
1
0
9
8
1
0
7
2
1
0
9
.
8
3
08 1 . 41 4 5
7 0
2 1 . 4
6 3 9
W
M
o
d
e
l
A
R
N
U
1
8
G
C
F
A
2
A
R
N
U
2
4
G
C
F
A
2
H
D
1
3
4
5
6
3
5
2
0
3
A
R
N
U
1
8
G
C
F
U
2
A
R
N
U
2
4
G
C
F
U
2
1
2
5
6
6
3
9
1
9
0
(
u
n
i
t

:

m
m
)
2
0
3
N
a
m
e



1
A
i
r

d
i
s
c
h
a
r
g
e

g
r
i
l
l




2
A
i
r

s
u
c
t
i
o
n

g
r
i
l
l

N
u
m
b
e
r
D
e
s
c
r
i
p
i
t
i
o
n
(
u
n
i
t

:

m
m
)
1
2
Indoor unit
Floor Standing
11-8 11-8
F
l
o
o
r

S
t
a
n
d
i
n
g
4. Piping Diagrams
Heat Exchanger
Sirroco Fan
lndoor unit
EEV
:Heating
:Cooling
Filter
Filter
Th3 Th2
Th1
Refrigerant pipe connection port diameter
Model Gas Liquid
ARNU07GCEA2
12.7(1/2) 6.35(1/4)
ARNU07GCEU2
ARNU09GCEA2
12.7(1/2) 6.35(1/4)
ARNU09GCEU2
ARNU12GCEA2
12.7(1/2) 6.35(1/4)
ARNU12GCEU2
ARNU15GCEA2
12.7(1/2) 6.35(1/4)
ARNU15GCEU2
ARNU18GCFA2
12.7(1/2) 6.35(1/4)
ARNU18GCFU2
ARNU24GCFA2
15.88(5/8) 9.52(3/8)
ARNU24GCFU2
[Unit: mm(inch)]
LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor
Indoor unit
Floor Standing
11-9 11-9
F
l
o
o
r

S
t
a
n
d
i
n
g
5. Wiring Diagrams
CN-POWER
CN-MOTOR1
CN-MOTOR2
CN-COMM
CN-EEV
CN-PIPE/IN
CN-PIPE/OUT
CN-ROOM
CN-REMO
CN-OPTION Option PCB Communication between main and option
CN-ZONE Zone controller Zone control line
CN-DISPLAY RF Remote controller RF Remote control line
CN-CC Dry contact Dry contact line
CONNECTOR
NUMBER
AC power supply
Fan motor output
Fan motor output
Communication
Float switch input
Suction pipe sensor
Discharge pipe sensor
Room sensor
Remote controller
AC Power line input for indoor controller
Motor output of BLDC
Motor output of BLDC
Communication between indoor and outdoor
EEV Control output
Pipe in thermistor
Pipe out thermistor
Room thermistor
Remote control line
LOCATION POINT FUNCTION
CE/CF Chassis
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor
CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.
Indoor unit
Floor Standing
11-10 11-10
F
l
o
o
r

S
t
a
n
d
i
n
g
6. Capacity Tables
6.1 Cooling Capacity
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.3 2.9 4.7 2.8
12 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.3 2.9 4.7 2.8
14 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.3 2.9 4.6 2.8
16 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.3 2.9 4.6 2.7
18 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.3 2.9 4.5 2.7
20 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.3 2.9 4.4 2.7
21 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.3 2.9 4.4 2.6
23 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.3 2.9 4.3 2.6
25 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.2 2.8 4.3 2.6
27 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.1 2.8 4.2 2.5
29 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.1 2.7 4.2 2.5
31 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.0 2.7 4.1 2.5
33 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.0 2.6 4.0 2.4
35 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 3.9 2.6 4.0 2.4
37 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.7 2.7 3.8 2.5 3.9 2.3
39 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.7 2.6 3.7 2.5 3.8 2.3
2.8
3.6
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
10 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.9 1.7
12 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.9 1.6
14 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.8 1.6
16 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.8 1.6
18 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.6
20 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.6
21 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.5
23 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.6 1.5
25 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.6 1.5
27 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.6 1.5
29 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.5 1.5
31 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.5 1.4
33 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.4 1.5 2.5 1.4
35 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.4 1.5 2.4 1.4
37 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.3 1.5 2.4 1.4
39 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.2 1.5 2.3 1.5 2.3 1.4
10 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.7 2.2
12 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.6 2.1
14 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.6 2.1
16 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.5 2.1
18 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.5 2.1
20 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
21 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
23 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
25 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.3 2.2 3.3 2.0
27 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.2 2.1 3.3 1.9
29 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.2 2.1 3.2 1.9
31 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.1 2.1 3.2 1.9
33 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.1 2.0 3.1 1.9
35 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.0 2.0 3.1 1.8
37 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 2.9 2.1 3.0 1.9 3.0 1.8
39 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 2.9 2.0 2.9 1.9 3.0 1.8
2.2
Cooling capacity
Indoor unit
Floor Standing
11-11 11-11
F
l
o
o
r

S
t
a
n
d
i
n
g
Notes:
TC: Total Capacity(kW) SHC: Sensible Heat Capacity(kW)
Capacity
Index
Outdoor
air temp.
(DB, C)
Indoor air temp. (DB/WB, C)
20 23 26 27 28 30 32
14 16 18 19 20 22 24
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.3 5.4
12 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.2 5.3
14 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.1 5.2
16 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.0 5.2
18 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.8 5.1
20 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.7 5.0
21 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.7 5.0
23 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.5 4.9
25 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.4 5.4 8.4 4.8
27 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.2 5.2 8.3 4.8
29 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.1 5.2 8.2 4.7
31 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.0 5.1 8.1 4.6
33 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 7.8 5.0 7.9 4.6
35 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 7.7 4.9 7.8 4.5
37 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.4 5.1 7.5 4.8 7.7 4.4
39 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.2 5.0 7.4 4.7 7.6 4.4
5.6
7.1
10 3.0 2.7 3.6 3.0 4.2 3.3 4.5 3.3 4.8 3.4 5.4 3.6 5.9 3.6
12 3.0 2.7 3.6 3.0 4.2 3.3 4.5 3.3 4.8 3.4 5.4 3.6 5.8 3.5
14 3.0 2.7 3.6 3.0 4.2 3.3 4.5 3.3 4.8 3.4 5.4 3.6 5.8 3.5
16 3.0 2.7 3.6 3.0 4.2 3.3 4.5 3.3 4.8 3.4 5.4 3.6 5.7 3.4
18 3.0 2.7 3.6 3.0 4.2 3.3 4.5 3.3 4.8 3.4 5.4 3.6 5.6 3.4
20 3.0 2.7 3.6 3.0 4.2 3.3 4.5 3.3 4.8 3.4 5.4 3.6 5.5 3.3
21 3.0 2.7 3.6 3.0 4.2 3.3 4.5 3.3 4.8 3.4 5.4 3.6 5.5 3.3
23 3.0 2.7 3.6 3.0 4.2 3.3 4.5 3.3 4.8 3.4 5.4 3.6 5.4 3.3
25 3.0 2.7 3.6 3.0 4.2 3.3 4.5 3.3 4.8 3.4 5.4 3.6 5.3 3.2
27 3.0 2.7 3.6 3.0 4.2 3.3 4.5 3.3 4.8 3.4 5.4 3.6 5.3 3.2
29 3.0 2.7 3.6 3.0 4.2 3.3 4.5 3.3 4.8 3.4 5.4 3.6 5.2 3.1
31 3.0 2.7 3.6 3.0 4.2 3.3 4.5 3.3 4.8 3.4 5.4 3.6 5.1 3.1
33 3.0 2.7 3.6 3.0 4.2 3.3 4.5 3.3 4.8 3.4 5.4 3.6 5.0 3.0
35 3.0 2.7 3.6 3.0 4.2 3.3 4.5 3.3 4.8 3.4 5.4 3.6 5.0 3.0
37 3.0 2.7 3.6 3.0 4.2 3.3 4.5 3.3 4.8 3.4 5.4 3.6 4.9 2.9
39 3.0 2.7 3.6 3.0 4.2 3.3 4.5 3.3 4.8 3.4 5.4 3.6 4.8 2.9
10 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.4 4.3
12 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.3 4.2
14 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.2 4.2
16 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.1 4.1
18 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.0 4.1
20 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.9 4.0
21 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.8 4.0
23 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.7 3.9
25 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.6 4.3 6.6 3.9
27 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.4 4.2 6.6 3.8
29 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.4 4.1 6.5 3.8
31 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.3 4.1 6.4 3.7
33 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.2 4.0 6.3 3.7
35 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.0 3.9 6.2 3.6
37 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 5.8 4.1 5.9 3.8 6.1 3.6
39 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 5.7 4.0 5.8 3.8 6.0 3.5
4.5
Cooling capacity
Indoor unit
Floor Standing
11-12 11-12
F
l
o
o
r

S
t
a
n
d
i
n
g
Notes:
TC: Total Capacity
6.2 Heating Capacity
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 1.7 1.7 1.7 1.7 1.7 1.7
-18.8 -19.0 1.7 1.7 1.7 1.7 1.7 1.7
-16.7 -17.0 1.8 1.8 1.8 1.8 1.8 1.8
-14.7 -15.0 1.9 1.9 1.7 1.9 1.9 1.9
-12.6 -13.0 2.0 2.0 1.8 2.0 2.0 2.0
-10.5 -11.0 2.1 2.1 1.9 2.1 2.1 2.1
-9.5 -10.0 2.2 2.2 1.9 2.2 2.2 2.1
-8.5 -9.1 2.2 2.2 2.0 2.2 2.2 2.1
-7.0 -7.6 2.3 2.3 2.0 2.2 2.2 2.2
-5.0 -5.6 2.4 2.4 2.1 2.3 2.3 2.2
-3.0 -3.7 2.5 2.5 2.2 2.4 2.4 2.2
0.0 -0.7 2.6 2.6 2.3 2.4 2.4 2.2
3.0 2.2 2.8 2.7 2.4 2.4 2.4 2.2
5.0 4.1 2.8 2.7 2.5 2.4 2.4 2.2
7.0 6.0 2.9 2.7 2.5 2.4 2.4 2.2
9.0 7.9 2.9 2.7 2.5 2.4 2.4 2.2
11.0 9.8 2.9 2.7 2.5 2.4 2.4 2.2
13.0 11.8 2.9 2.7 2.5 2.4 2.4 2.2
15.0 13.7 2.9 2.7 2.5 2.4 2.4 2.2
-19.8 -20.0 2.1 2.1 2.1 2.1 2.1 2.1
-18.8 -19.0 2.2 2.2 2.2 2.2 2.2 2.2
-16.7 -17.0 2.3 2.3 2.3 2.3 2.3 2.3
-14.7 -15.0 2.5 2.4 2.2 2.4 2.4 2.4
-12.6 -13.0 2.6 2.6 2.3 2.6 2.6 2.6
-10.5 -11.0 2.7 2.7 2.4 2.7 2.7 2.7
-9.5 -10.0 2.8 2.8 2.5 2.8 2.8 2.7
-8.5 -9.1 2.8 2.8 2.5 2.8 2.8 2.7
-7.0 -7.6 2.9 2.9 2.6 2.8 2.8 2.8
-5.0 -5.6 3.0 3.0 2.7 3.0 3.0 2.8
-3.0 -3.7 3.2 3.2 2.8 3.1 3.0 2.8
0.0 -0.7 3.4 3.4 3.0 3.1 3.0 2.8
3.0 2.2 3.6 3.4 3.1 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.7 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.7 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.7 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.7 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.7 3.4 3.2 3.1 3.0 2.8
-19.8 -20.0 2.7 2.7 2.7 2.6 2.6 2.6
-18.8 -19.0 2.8 2.8 2.8 2.8 2.7 2.7
-16.7 -17.0 2.9 2.9 2.9 2.9 2.9 2.9
-14.7 -15.0 3.1 3.0 2.7 3.0 3.0 3.0
-12.6 -13.0 3.2 3.2 2.9 3.2 3.2 3.2
-10.5 -11.0 3.4 3.4 3.0 3.4 3.4 3.4
-9.5 -10.0 3.4 3.4 3.1 3.4 3.4 3.4
-8.5 -9.1 3.5 3.5 3.2 3.5 3.5 3.4
-7.0 -7.6 3.6 3.6 3.3 3.6 3.6 3.5
-5.0 -5.6 3.8 3.8 3.4 3.7 3.7 3.5
-3.0 -3.7 4.0 4.0 3.5 3.9 3.8 3.5
0.0 -0.7 4.2 4.2 3.7 3.9 3.8 3.5
3.0 2.2 4.4 4.3 3.9 3.9 3.8 3.5
5.0 4.1 4.5 4.3 4.0 3.9 3.8 3.5
7.0 6.0 4.6 4.3 4.0 3.9 3.8 3.5
9.0 7.9 4.6 4.3 4.0 3.9 3.8 3.5
11.0 9.8 4.6 4.3 4.0 3.9 3.8 3.5
13.0 11.8 4.6 4.3 4.0 3.9 3.8 3.5
15.0 13.7 4.6 4.3 4.0 3.9 3.8 3.5
2.2
2.8
3.6
Notes:
TC: Total Capacity(kW)
Heating capacity
Indoor unit
Floor Standing
11-13 11-13
F
l
o
o
r

S
t
a
n
d
i
n
g
Notes:
TC: Total Capacity(kW)
Capacity
Index
Outdoor air
temp.
DB(C) WB(C)
Indoor air temp. (DB, C)
16.0 18.0 20.0 21.0 22.0 24.0
TC TC TC TC TC TC
kW kW kW kW kW kW
-19.8 -20.0 3.4 3.4 3.4 3.3 3.3 3.3
-18.8 -19.0 3.5 3.5 3.5 3.5 3.4 3.4
-16.7 -17.0 3.7 3.7 3.7 3.7 3.7 3.6
-14.7 -15.0 3.9 3.8 3.4 3.8 3.8 3.8
-12.6 -13.0 4.1 4.1 3.6 4.0 4.0 4.0
-10.5 -11.0 4.3 4.3 3.8 4.3 4.2 4.2
-9.5 -10.0 4.3 4.3 3.9 4.3 4.3 4.3
-8.5 -9.1 4.4 4.4 4.0 4.4 4.4 4.3
-7.0 -7.6 4.6 4.6 4.1 4.4 4.4 4.4
-5.0 -5.6 4.8 4.8 4.3 4.6 4.6 4.4
-3.0 -3.7 5.0 5.0 4.4 4.8 4.7 4.4
0.0 -0.7 5.3 5.3 4.6 4.8 4.7 4.4
3.0 2.2 5.6 5.4 4.9 4.8 4.7 4.4
5.0 4.1 5.6 5.4 5.0 4.8 4.7 4.4
7.0 6.0 5.8 5.4 5.0 4.8 4.7 4.4
9.0 7.9 5.8 5.4 5.0 4.8 4.7 4.4
11.0 9.8 5.8 5.4 5.0 4.8 4.7 4.4
13.0 11.8 5.8 5.4 5.0 4.8 4.7 4.4
15.0 13.7 5.8 5.4 5.0 4.8 4.7 4.4
-19.8 -20.0 4.2 4.2 4.2 4.2 4.2 4.2
-18.8 -19.0 4.3 4.3 4.3 4.3 4.3 4.3
-16.7 -17.0 4.6 4.6 4.6 4.6 4.6 4.5
-14.7 -15.0 4.9 4.8 4.3 4.8 4.8 4.8
-12.6 -13.0 5.1 5.1 4.5 5.0 5.0 5.0
-10.5 -11.0 5.4 5.4 4.8 5.4 5.3 5.3
-9.5 -10.0 5.4 5.4 4.9 5.4 5.4 5.4
-8.5 -9.1 5.5 5.5 5.0 5.5 5.5 5.4
-7.0 -7.6 5.7 5.7 5.1 5.6 5.6 5.5
-5.0 -5.6 6.0 6.0 5.4 5.8 5.8 5.5
-3.0 -3.7 6.2 6.2 5.5 6.1 5.9 5.5
0.0 -0.7 6.6 6.6 5.8 6.1 5.9 5.5
3.0 2.2 7.0 6.7 6.2 6.1 5.9 5.5
5.0 4.1 7.1 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.2 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.2 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.2 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.2 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.2 6.7 6.3 6.1 5.9 5.5
-19.8 -20.0 5.4 5.4 5.4 5.3 5.3 5.3
-18.8 -19.0 5.5 5.5 5.5 5.5 5.4 5.4
-16.7 -17.0 5.8 5.8 5.8 5.8 5.8 5.8
-14.7 -15.0 6.2 6.1 5.5 6.1 6.1 6.1
-12.6 -13.0 6.5 6.5 5.8 6.4 6.4 6.4
-10.5 -11.0 6.8 6.8 6.0 6.8 6.7 6.7
-9.5 -10.0 6.9 6.9 6.2 6.9 6.9 6.8
-8.5 -9.1 7.0 7.0 6.3 7.0 7.0 6.8
-7.0 -7.6 7.3 7.3 6.5 7.1 7.1 7.0
-5.0 -5.6 7.6 7.6 6.8 7.4 7.4 7.0
-3.0 -3.7 7.9 7.9 7.0 7.7 7.5 7.0
0.0 -0.7 8.4 8.4 7.4 7.8 7.5 7.0
3.0 2.2 8.9 8.6 7.8 7.8 7.5 7.0
5.0 4.1 9.0 8.6 8.0 7.8 7.5 7.0
7.0 6.0 9.2 8.6 8.0 7.8 7.5 7.0
9.0 7.9 9.2 8.6 8.0 7.8 7.5 7.0
11.0 9.8 9.2 8.6 8.0 7.8 7.5 7.0
13.0 11.8 9.2 8.6 8.0 7.8 7.5 7.0
15.0 13.7 9.2 8.6 8.0 7.8 7.5 7.0
4.5
5.6
7.1
Heating capacity
Indoor unit
Floor Standing
11-14 11-14
F
l
o
o
r

S
t
a
n
d
i
n
g
7. Air velocity and Temperature Distribution(Reference Data)
ARNU24GCFA2- Installation on floor
2.7m
2m
1m
0m

8m

7m

6m

5m

4m

3m

2m

1m

0m
Air velocity [m/s]
Temperature [C]
0.75
1.25
1.0
2.7m
2m
1m
0m

8m

7m

6m

5m

4m

3m

2m

1m

0m
24
25
23
2.7m
2m
1m
0m

8m

7m

6m

5m

4m

3m

2m

1m

0m
Air velocity [m/s]
0.75
0.5
1.0
1.25
Temperature [C]
2.7m
2m
1m
0m

8m

7m

6m

5m

4m

3m

2m

1m

0m
28
29
30
31
Cooling
Discharge angle:45
Heating
Discharge angle:60
Indoor unit
Floor Standing
11-15 11-15
F
l
o
o
r

S
t
a
n
d
i
n
g
8. Electric Characteristics
Units
Model Type Hz Volts Voltage Range
CE
CE
CE
50 220-240
MAX.264
CE
MIN.198
CF
CF
Power Supply IFM Input(W)
MCA MFA kW FLA Cooling Heating
Symbols:
MCA: Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor
Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA
MFA 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the MCA.
5. Instead of fuse, use Circuit Breaker.
ARNU07GCEA2
ARNU07GCEU2
ARNU09GCEA2
ARNU09GCEU2
ARNU12GCEA2
ARNU12GCEU2
ARNU15GCEA2
ARNU15GCEU2
ARNU18GCFA2
ARNU18GCFU2
ARNU24GCFA2
ARNU24GCFU2
ARNU07GCEA2
ARNU07GCEU2
ARNU09GCEA2
ARNU09GCEU2
ARNU12GCEA2
ARNU12GCEU2
ARNU15GCEA2
ARNU15GCEU2
ARNU18GCFA2
ARNU18GCFU2
ARNU24GCFA2
ARNU24GCFU2
0.22 15 0.028 0.17 30 30
0.22 15 0.028 0.17 30 30
0.22 15 0.028 0.17 30 30
0.22 15 0.028 0.17 30 30
0.22 15 0.028 0.17 30 30
0.22 15 0.028 0.17 30 30
0.22 15 0.028 0.17 30 30
0.22 15 0.028 0.17 30 30
0.55 15 0.076 0.44 80 80
0.55 15 0.076 0.44 80 80
0.55 15 0.076 0.44 80 80
0.55 15 0.076 0.44 80 80
0.22 15 0.028 0.17 30 30
0.22 15 0.028 0.17 30 30
0.22 15 0.028 0.17 30 30
0.22 15 0.028 0.17 30 30
0.22 15 0.028 0.17 30 30
0.22 15 0.028 0.17 30 30
0.22 15 0.028 0.17 30 30
0.22 15 0.028 0.17 30 30
0.55 15 0.076 0.44 80 80
0.55 15 0.076 0.44 80 80
0.55 15 0.076 0.44 80 80
0.55 15 0.076 0.44 80 80
CE
CE
CE
60 220
MAX.242
CE
MIN.198
CF
CF
Indoor unit
Floor Standing
11-16 11-16
F
l
o
o
r

S
t
a
n
d
i
n
g
9. Sound Levels
Overall
Sound Pressure Level
Notes:
- Sound measured at 1.5m away from
the center of the unit.
- Data is valid at free field condition
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.
Model
ARNU07GCEA2 ARNU07GCEU2
ARNU09GCEA2 ARNU09GCEU2
ARNU12GCEA2 ARNU12GCEU2
ARNU15GCEA2 ARNU15GCEU2
ARNU18GCFA2 ARNU18GCFU2
ARNU24GCFA2 ARNU24GCFU2
Sound Levels dB(A)
H L M
1.5m
1.5m
With Case
E
Microphone
Du
(Fie
35
36
37
38
40
43
33
34
35
37
37
40
31
32
33
35
34
37
ARNU07GCEA2 ARNU09GCEA2 ARNU12GCEA2
ARNU07GCEU2 ARNU09GCEU2 ARNU12GCEU2
ARNU18GCFA2 ARNU15GCEA2
ARNU15GCEU2
ARNU24GCFA2
ARNU18GCFU2
ARNU24GCFU2
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
Octave Band Center Frequency (Hz)
O
c
t
a
v
e

B
a
n
d

S
o
u
n
d

P
r
e
s
s
u
r
e

L
e
v
e
l

(
d
B

r
e

2
0

P
a

)
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
Indoor unit
Floor Standing
11-17 11-17
F
l
o
o
r

S
t
a
n
d
i
n
g
10. Installation
Please read this instruction sheet completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
10.1 Features
Remote Controller
Air Outlet
Control panel
Control panel
Air Filter
Air Inlet
Air Inlet
Air filter
(At Air Inlet)
Remote Controller
TEMP
[CEA/CFA Type]
[CEU/CFU Type]
Indoor unit
Floor Standing
11-18 11-18
F
l
o
o
r

S
t
a
n
d
i
n
g
10.2 Selection of the best location
Indoor unit
Install the air conditioner in the location that satisfies the follow-
ing conditions.
The place shall easily bear a load exceeding four times the
indoor units weight.
Sufficient space should be available to inspect the unit as in
the figure shown on the right.
The place where the unit is installed shall be leveled.
The place shall be suitable for easy connection of the indoor
unit with the outdoor unit.
The place where the unit is installed should not be affected
by electrical noise.
The place where air circulation in the room will be good .
There should not be any heat source or steam near the unit
Service space
Select an installation site where the following conditions are
satisfied and that meets your customer's approval.
Where the floor is strong enough to bear the indoor unit
weight.
Where the floor is not significantly inclined.
Where nothing blocks the air passage.
Where condensate can be properly drained.
Where sufficient clearance for installation and maintenance
can be ensured.
Where there is no possibility of flammable gas leakage.
Where optimum air distribution can be ensured.
Where piping between indoor and outdoor units is possible
within the allowable limit (Refer to the installation manual of
the outdoor unit.)
Keep the indoor and outdoor unit, power cable and transmis-
sion wiring, at least 1m from TVs and radios, to prevent dis-
torted pictures and static.(Depending on the type and source
of the electrical waves, static may be heard even when more
than 1 m away.)
6
5
4
8
0

o
r

m
o
r
e
B
o
r
m
o
r
e
M
a
in
te
n
a
n
c
e
a
r
e
a
Window
A
o
r
m
o
r
e
2
0

o
r
m
o
r
e
100 or
more
100 or
more
175 or
more
Front side
Base
Air flow
direction
Air inlet
direction
1000 or
more
Window
[IMPORTANT]
Leave sufficient clearance
for air inlet and maintenance.
Type A B
CEU Type 788 1080
CFU Type 1066 1358
(Unit: mm)
Indoor unit
Floor Standing
11-19 11-19
F
l
o
o
r

S
t
a
n
d
i
n
g
Bolt pitch
(Unit:mm)
CEA, CEU 858
CFA, CFU 1136
Type
A
1
9
8
A
2
7
0
(1)
(1)
(2)
(2)
(3)
How to open/close front panel
Positioning of holes for fastening to the wall
How to open/close the front panel
(1) Open the lid of control panel(Both left and right)
(2) Remove screws(Both left and right)
(3) Lift the front panel of the unit
To close, perform the procedure in opposite
order.
1. Use the installationmount for installation. Check
whether the wall is strong enough to bear the
weight of the unit or not. if there is a risk, reinforce
the wall before installing the unit.
2. The unit requires a minimum 100 mm clearance
below the unit for air intake. Also, ensure the unit is
leveled when installed so that drainage flows
smoothly. If inclined, water can leak.
3. Depending upon the shape and nature of the wall
surface, operating sound may become bigger.
Indoor unit
Floor Standing
11-20 11-20
F
l
o
o
r

S
t
a
n
d
i
n
g
Drain piping must have downward slope(1/50 to 1/100): be sure not to provide up-and-down slope to prevent
reverse flow.
During drain piping connection, be careful not to exert extra force on the drain port on the indoor unit.
The outside diameter of the drain connection to the indoor unit is 21mm.
Be sure to install heat insulation on the drain piping
If converging multiple drain pipes, install according to the procedure shown below.
After piping work is finished, check for drainage.
Be sure to insulate all indoor units.
Piping material: Polyvinyl chloride pipe 25mm and
pipe fittings
Heat insulation material: Polyethylene foam with
thickness more than 10 mm.
Slope downwards at a gradient
of at least 1/100
10.3 Drain piping work
10.4 How to connect wirings
Remove the electric parts Box cover and connect the wiring
Power Supply wiring
ground wiring
(Field wiring) Fasten with
accessory clamp
Transmission wiring
(Field wiring)
Power supply wiring
ground wiring
Fasten with clamp
Transmission wiring
Indoor unit
Floor Standing
11-21 11-21
F
l
o
o
r

S
t
a
n
d
i
n
g
10.5 Wiring Connection
Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively.
Terminal Block Indoor
1(L) 2(N) 3 4
INDOOR POWER INPUT
A - - - - - - B A B
GND 12V DRY2 DRY1 INTERNET IDU SODU Outdoor
Unit
WARNING : Make sure that the screws of the terminal are free from looseness.
CAUTION:
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have a separate power circuit specifically for the air conditioner. As for the method of
wiring, follow the circuit diagram posted on the inside of control cover.
2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from
vibrations to which the unit is subjected during the course of transportation. Check them and make
sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the wires.)
3) Specification of power source.
4) Confirm that electrical capacity is sufficient.
5) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on
the name plate.
6) Confirm that the cable thickness is as specified in the power source specification.
(Particularly note the relation between cable length and thickness.)
7) In a wet or moist area, always install an earth leakage circuit breaker.
8) The following would be caused by voltage drop.
Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the nor-
mal function of the overload.
9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and
have an air gap contact separation of at least 3mm in each active(phase) conductor.
Indoor unit
Floor Standing
11-22 11-22
F
l
o
o
r

S
t
a
n
d
i
n
g
WIRED REMOTE CONTROLLER INSTALLATION
Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average tempera-
ture.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
Fig.1 Typical locations for remote controller
5feet
(1.5meters)
no
no
no
yes
Remote Controller
TEMP
Remote Controller
TEMP
Remote Controller
TEMP
Indoor unit
Floor Standing
11-23 11-23
F
l
o
o
r

S
t
a
n
d
i
n
g
11. Accessories
Name
Dran
hose
Level adjustment
screw
Quantity
Shape
Insulation for
fitting
Clamp
(Tie Wrap)
[Other]
1 each.
(1) For gas pipe
(2) For liquid pipe
8 pcs. 1 EA 4
Operation
manual
Installation
manual
Use only those accessories (Standard or optional) which have designated specifications.
CAUTION
Standard Accessories
Indoor unit
Dip Switch &
Group Control Setting
D
i
p

S
w
i
t
c
h

&

G
r
o
u
p

C
o
n
t
r
o
l

S
e
t
t
i
n
g
1. Dip Switch Setting
2. Group Control Setting
Dip Switch &
Group Control Setting
Indoor unit
1. Dip Switch Setting
Dip Switch &
Group Control Setting
1 1
D
i
p

S
w
i
t
c
h

&

G
r
o
u
p

C
o
n
t
r
o
l

S
e
t
t
i
n
g
It is available Multi V indoor units (except for Wall mounted, Art cool Gallery,
Mirror) in Dip Switch setting and Group Control Setting.
For Multi V Models, Dip switch 1, 2, 6, 8 must be set OFF.
CAUTION
Function Description Setting Off Setting On Default
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
Communication
Cycle
Group Control
Dry Contact Mode
Installation
Heater linkage
Ventilator linkage
Vane selection
(Console)
Etc.
N/A (Default)
N/A (Default)
Selection of Master or Slave
Selection of Dry Contact
Mode
CST No function
Duct Fan continuous oper-
ation
CVT Selection of ceiling or
floor
Console Concealed or not
N/A
Selection of Ventilator link-
age
Selection of up/down side
Vane
Spare
-
-
Master
Wired/Wireless remote
controller
Selection of Manual or Auto
operation Mode
-
Continuous operation
Removal
Ceiling
General installation
-
Linkage Removal
Up side + Down side Vane
-
-
-
Slave
Auto
-
Working
Floor
Concealed
installation
-
Working
Up side Vane
Only
-
Off
Off
Off
Off
Off
Off
Off
Off
Indoor unit
2. Group Control Setting
Dip Switch &
Group Control Setting
2 2
D
i
p

S
w
i
t
c
h

&

G
r
o
u
p

C
o
n
t
r
o
l

S
e
t
t
i
n
g
2.1 Group Control 1
I Wired remote controller 1 + Indoor units
1. It is possible to 16 indoor units(Max) by one wired remote controller.
Set only one indoor unit to Master, set the others to Slave.
2. It is possible to connect with every type of indoor units.
3. It is possible to use wireless remote controller at the same time.
4. It is possible to connect with Dry Contact and Central controller at the same time.
The Master indoor unit is possible to recognize Dry Contact and Central controller only.
5. In case of any error occurs at indoor unit, display on the wired remote controller.
Exception of the error indoor unit, an individual indoor unit control possibility.
6. In case of Group Control, be limited additional functions of indoor unit.
- Selection of operation options (stop/mode/temperature)
- Control of flow rate (strong/middle/weak)
- Time reservation function
- Elevation grille
All kind of indoor units be set possible using a wireless remote controller, except cassette and duct types.
Refer to wireless remote controller manual for setting group control.
It is possible to connect indoor units since Feb. 2009.
In the other cases, please contact LGE.
GND
Signal
12 V
Master Slave Slave Slave
Master
Display Error Message
Only connect serial signal and GND lines
between slave indoor unit
LGAP Network System
Indoor unit
Dip Switch &
Group Control Setting
3 3
D
i
p

S
w
i
t
c
h

&

G
r
o
u
p

C
o
n
t
r
o
l

S
e
t
t
i
n
g
2.2 Group Control 2
I Wired remote controllers + Indoor units
1. It is possible to control N indoor units by wired remote controller M units. (M+N17 Units)
Set only one indoor unit to Master, set the others to Slave.
Set only one wired remote controller to Master, set the others to Slave.
Other than those, it is same with the Group Control 1.
2. It is possible to connect with every type of indoor units.
3. It is possible to use wireless remote controller at the same time.
4. It is possible to connect with Dry Contact and Central controller at the same time.
The Master indoor unit is possible to recognize Dry Contact and Central controller only.
5. In case of any error occurs at indoor unit, display on the wired remote controller.
Exception of the error indoor unit, an individual indoor unit control possibility.
6. In case of Group Control, be limited additional functions of indoor unit.
- Selection of operation options (stop/mode/temperature)
- Control of flow rate (strong/middle/weak)
- Time reservation function
- Elevation grille
All kind of indoor units be set possible using a wireless remote controller, except cassette and duct types.
Refer to wireless remote controller manual for setting group control.
It is possible to connect indoor units since Feb. 2009.
In the other cases, please contact LGE.
GND
Signal
12 V
Slave Slave Slave
Slave
Master
Display Error Message
Dont connect serial 12V line
Master
LGAP Network System
Indoor unit
Dip Switch &
Group Control Setting
4 4
D
i
p

S
w
i
t
c
h

&

G
r
o
u
p

C
o
n
t
r
o
l

S
e
t
t
i
n
g
2.3 2 Remote Control
I Wired remote controller 2 + Indoor unit 1
1. It is possible to connect two wired remote controllers with one indoor unit.
2. Every types of indoor unit is possible to connect two remote controller.
3. It is possible to use wireless remote controller at the same time.
4. It is possible to connect with Dry Contact and Central controller at the same time.
5. In case of any error occurs at indoor unit, display on the wired remote controller.
6. There isnt limits of indoor unit function.
GND
Signal
12 V
LGAP Network System
Display Error Message
Master
Master Slave
P/No.: 3828A24007X
Air Conditioner
20 Yeouido-dong, Yeongdeungpo-gu,
Yeouido P.O.Box 335 Seoul,
150-721, Korea.
http://www.lgeaircon.com
All rights reserved
Printed in Korea April/2009
The specifications, designs, and
information in this brochure are subject to
change without notice.
The air conditioners manufactured by LG
have received ISO9001 certificate for
quality assurance and ISO14001
certificate for environmental
management system.
File No. : A8974
Volume:1
Certificate No. :