Sie sind auf Seite 1von 1

Section 01060 - Page 8

or in accordance with local Laws, codes, and regulations.


3.2.2.4 USE OF EXISTING ROADS AS HAUL ROUTES
The Contractor shall be responsible for coordinating with the base authorities for use of any existing
roads as haul routes. Construction, and routing of new haul roads, and/or upgrading of existing roads to
carry anticipated construction traffic shall be coordinated with the Base authorities and is the sole
responsibility of the Contractor.
3.2.2.5 EMPLOYEE PARKING
The Contractors employees may be allowed parking on the military installation. The Contractor is
responsible for transporting workers (local nationals) from off post to the worksite, coordinating security
identification screening, and cooperating in gate searches with the base authorities. The government
reserves the right to terminate any and all Contractor parking at any time.
3.2.3 BATCH PLANT
The Contractor shall obtain local authorizations, permits and licenses necessary to establish his quarry
operations, batching operations and haul routes in accordance with Host Country Rules and Customs.
3.2.4 GOVERNMENT FIELD OFFICE BID OPTION
3.2.4.1 GENERAL
The Contractor shall furnish a temporary field office complete with the services, furniture, and features
indicated below for use by US Army Corps of Engineers personnel and other persons as designated by
the Contracting Officer. The Contractor shall fully maintain and repair all facilities, furnishings and
equipment listed below. All facilities, furnishings, materials and equipment provided and / or installed by
the Contractor under this Contract shall remain the property of the Contractor at the completion of the
Contract.
3.2.4.2 FEATURES
a. This facility shall consist of a standard 8 ft. x 20 ft. conex fitted out and furnished as described below.
The exterior dimensions shall be nominally 2.44M wide x 6.09M long x 2.6M high. Openings in
container walls shall be cut in such a manner as to maintain the structural integrity of the container.
b. The following features and services shall be included:
1. The interior walls and ceiling of the container shall be framed out with 38mm x 89mm wood or
steel studs spaced at 600mm on center with 13mm gypsum board;
2. The interior floors shall be framed out with 38mm x 89mm wood or steel studs spaced at
400mm on center with 16mm plywood;
3. The floor finish shall be 3mm thick linoleum;
4. Walls, floor, and ceiling shall be insulated with 89mm R-13 fiberglass batt insulation;
5. The exterior metal color shall be tan semi-gloss;
6. One (1) exterior metal door with door lock, lockable by key from both inside and outside;
7. Two (2) operable windows;
8. All hardware shall have satin chrome or satin stainless steel finish;
9. Connection to power operating 24 hours per day, 7 days a week;
10. One (1) new split pack heat pump (12,000 BTU), securely mounted;
11. One (1) ceiling-mounted fluorescent wraparound light fixture;
W912DQ-13-R-4034