Sie sind auf Seite 1von 1

Prjct ID No :

Calc. by :
Chk'd. by :
Appr'd. by :
DESIGN PARAMETERS DESIGN LOADS Calculate Uniform Dead Load
Concrete Strength, f'
c
(MPa) 19.00 Dead Load, W
DL
(kPa) 4.88 Slab Weight (kPa) 2.36
Steel Yield Strength, f
y
(Mpa) 276.00 Live Load, W
LL
(kPa) 2.40 Floor Finish + Misc. (kPa) 0.77
Unit Weight of Concrete (kN/m
3
) 23.60 Total Design Load, W
u
(kPa) 9.70 Others (Ceilings) (kPa) 0.75
Main bar diameter,
m
(mm) 12 Partition Load (kPa) 1
Longer dimension of slab, L (mm) 5300
Shorter dimension of slab, B (mm) 4450 Two-way slab requirement
Width of slab, b (meter-strip) (mm) 1000 Ratio B/L 0.840
Thickness of Slab, t (mm) 100 m 0.840

1 0.85 CASE 1
Concrete Cover, cc (mm) 20 S
max
(mm) 300
SLAB MARK S-1 All Edges Discontinuous
Calculate Moment Coefficients
-C
a
= 0.000 Negative moment coefficient along the shorter dimension due to uniform dead load plus live load
-C
b
= 0.000 Negative moment coefficient along the longer dimension due to uniform dead load plus live load
+C
aDL
= 0.056 Positive moment coefficient along the shorter dimension due to dead load
+C
aLL
= 0.056 Positive moment coefficient along the shorter dimension due to live load
+C
bDL
= 0.023 Positive moment coefficient along the longer dimension due to dead load
+C
bLL
= 0.023 Positive moment coefficient along the longer dimension due to live load
410.4.3 Calculate Steel Ratio Requirements
410.6.1
max = 0.75*
bal

min = (f'
c)
/(4*f
y
)
min = 1.4/f
y
= 0.75 * [(0.85*
1
*f'
c
/f
y
) + (600/600 + f
y
)] = 0.0039 < = 0.0051

max
= 0.5510 Therefore:
min = 0.0051
Calculate Positive and Negative Moments
Negative Moment, M
a
(along short direction) Positive Moment due to dead load, M
a
(along short direction)Positive Moment due to dead load, M
b
(along long direction)
M
a = C
a
W
u
L
a
2
M
aDL
= C
aDL
W
uDL
L
a
2
M
bDL
= C
bDL
W
uDL
L
b
2
M
a = 0.00 kN-m M
aDL
= 6.49 kN-m M
bDL
=
Negative Moment, M
b
(along long direction) Positive Moment due to live load, M
a
(along short direction) Positive Moment due to live load, M
b
(along long direction)
M
b = C
b
W
u
L
b
2
M
aLL
= C
aLL
W
uLL
L
a
2
M
aLL
= C
bLL
W
uLL
L
b
2
M
b = 0.00 kN-m M
aLL
= 4.26 kN-m M
aLL
=
Calculate Reinforcements
Mu (kN-m)
d (mm)

req'd
Use
As
Ab
S
req'd
(mm)
Use S (mm)
Calculate Shear Coefficients
C
a
= 0.71 Shear coefficients on supports along short side
C
b
= 0.29 Shear coefficients on supports along long side
Chc'k Slab on Shear
Shear Demand
Va = 0.5C
a
Wul
a = 15.32 kN
Vb = 0.5C
b
Wul
b = 7.45 kN
Vu = max (Va , Vb) = 15.32 kN
411.4.1.1 Shear Capacity
Vc = 0.75*(1/6)sqrt(fc')(b)(d) = 40.32 kN
CD Ratio = 2.63 Compliant
2.48 kN-m
3.78 kN-m
2.09
Negative Moment
along Long direction
(Discontinuous Edge)
0.00 0.00 10.75 6.26 3.58
Negative Moment
along Short direction
(Continuous Edge)
Negative Moment along
Long direction
(Continuous Edge)
Positive Moment
along Short direction
Positive Moment
along Long direction
Negative Moment
along Short direction
(Discontinuous
Edge)
74 74 74
0.00507
0.00000 0.00000 0.00853 0.00480 0.00270 0.00156
0.00507 0.00507 0.00853 0.00507 0.00507
375.36 375.36 375.36
113.10 113.10 113.10 113.10 113.10
Item
74 74
300 300
301.30 301.30 179.23 301.30 301.30 301.30
300
113.10
375.36 375.36 631.01
74
300 300 170
A.H.Sinconiegue, C.E
A.H.Sinconiegue, C.E
A.H.Sinconiegue, C.E
Consultancy Services for Detailed Structural Investigation & Design of Proposed Naganaga 1 Storey
Extension Office Building
SID - PBEXT - 001
22-Aug-14
JCOM CONSTRUCTION INC.
Two Way Slab Design
Date :
Client :
Subject :
Tacloban City, Leyte, Philippines

Das könnte Ihnen auch gefallen