HumaCount60

TS
System Overview Cat.No. 16420/60
Analyzer type Automatic hematology Analyzer
Reagent system Closed
# of Parameters 18, 3-part differential of WBC
Throughput 60 samples / hour
Barcode reader External barcode reader (optional)
Reaction / reading system Impedance method (2 chambers)
LED 540 nm for HGB measurement
Languages available English, French, German, Indonesian,
Italian, Portuguese, Russian, Spanish, Czech, Polish
User interface Color touch screen LCD, 320 x 240 -dots
high-contrast, backlit

Specifications & more
> System Specications
> Reagents
> Accessories
> Consumables
Tests Parameters WBC, LYM, MON, GRA, LYM%, MON%, GRA%, HGB, RBC, HCT,
MCV, MCH, MCHC, RDWcv, RDWsd, PLT, PCT, MPV, PDWcv, PDWsd
Calibration 1-, 2-, or 3-measurement automatic
Manual (factors) calibration of WBC, HGB, RBC, PLT, MCV (or HCT), RDW, MPV
Independent calibration of pre-diluted mode
Veterinary mode No
Self check Yes
Flags / messages Interpretative messages
Warning flags

Sample Sample type Whole blood, diluted blood
Sample vessels Open tube system with automatic sample rotor
Standard EDTA tubes
Sample positions 1
Sampling volume 25 l of whole blood or in pre-diluted mode
Dilution Yes, internal

Reagent Reagent type Diluent
Lyse
Cleaner

Liquid Handling Liquid transportation Dilutor pumps, vacuum
Liquid level sensors Yes, internal

Reading Light source Green LED for HGB
Wavelength pre-installed 540 nm
Detector Light to frequency converter
Aperture diameter 70 m (RBC/PLT)
80 m (WBC)

HumaCount60
TS
Automatic Hematology System

Data Processing Memory for QC, records including flags and histograms
Memory capacity 1.000
Reports for Result, QC, self check, calibration
Quality control module 16- and 64-day Levey-Jennings charts
Separate QC database (6 level)
Max. number of control levels 6
Warnings Range, linearity, errors
Printer Built-in thermal printer, 58 mm wide roll paper, full report with histograms
External all Hp Printers via USB
LIS Special protocol on USB 2.0 port

General Physical dimensions (W x D x H) Instrument without any components: 32 x 26 x 36.5 cm
Space required for routine use: 52 x 46 x 50 cm
Packaging: 50 x 41 x 59 cm
Weight: Gross: 12.5 kg, net: 12 kg
Electrical requirements External auto-ranging power unit for 100...120 or
200...240 Vac, 5060Hz, 60 VA
Environmental Operating: temperature: 1530C, humidity: < 80 % non-condensing
Storage: temperature: 1530C, humidity: < 80 % non-condensing
Wash / waste tank Waste Container 20 L

Characteristics
Parameter: Accuracy Reproducibility
(CV)
Carry-over sample
to sample
Test range Unit
WBC 3% 3% <1% 4.0-20.0 10
3
/l
RBC 3% 2% <1% 4.0-15.0 10
6
/l
HCT 3% 3% <1% 25.0-50.0 %
MCV 2% 1% N/A 5-9 fl
HGB 2% 2% <1% 9-16 g/dl
PLT 5% 5% <3% or <20 200-900 10
3
/l
System Reagents Unit/Size Cat. No
HC-Diluent 20 L 17400/10
HC-Lyse CF (Cyanid-free reagent) 1 L 17400/20
HC-Cleaner 1 L 17400/30
HC-CONTROL (Levels 1, 2, 3) 3 x 2.5 ml 17400/40
Standard Accessories Quantity Cat. No
External Power Supply and Cable 1 16420/168
Reagent Tubing Kit 1 16420/622
1 x Diluent Tube (green)
1 x Lyse Tube (yellow)
1 x Cleaner Tube (blue)
2 x Waste Tube (red)
1 x Cleaning Tube Kit
4 x Caps for Reagent Containers
Thermal Printer Paper 2 rolls 16420/621
Tube Adapter I 1 16420/180
Tube Adapter II 1 16420/181
Tube Adapter III 1 16420/323
Tube for Vacuum Pump 1 .
User Manual 1 16420/601
Waste Container 20 L + Box 1 .
Accessories Cat. No.
Tube Adapter I 16420/180
Tube Adapter II 16420/181
Tube Adapter III 16420/323
UPS1 KVA / 230V 18961
Consumables
Thermal Printer Paper (5 pcs.) 18144/5
Reagent Tubing 16420/622
HumaCount60
TS
System Reagents, Accessories,Consumables
1
6
4
2
0
/
6
0
/
2
0
1
2
-
0
1


2
0
1
2

H
u
m
a
n

G
m
b
H
Reagent Tubing Kit
Cat.No. 16420/622
Tube Adapter I
Cat.No. 16420/180
Main Screen Menu
Tube Adapter II
Cat.No. 16420/181
Tube Adapter III
Cat.No. 16420/323
Result Screen
HC-CONTROL (Level 1, 2, 3)
Cat.No. 17400/40

Das könnte Ihnen auch gefallen