Sie sind auf Seite 1von 12

Project 1

23.08.2014
Operator
Telephone
Fax
e-Mail
Crompton Greaves Ltd. SSSG1215IH/FG STREETLIGHT LUMINAIRE / Luminaire
Data Sheet
See our luminaire catalog for an image of the
luminaire.
Luminous emittance 1:
Luminaire classification according to CIE: 99
CIE flux code: 49 82 98 99 71
Due to missing symmetry properties, no UGR table
can be displayed for this luminaire.
Page 1
Project 1
23.08.2014
Operator
Telephone
Fax
e-Mail
Street 1 / Planning data
Street Profile
Light loss factor: 0.70
Roadway 2 (Width: 4.000 m, Number of lanes: 1, tarmac: R3, q0: 0.070)
Luminaire Arrangements
Luminaire: Crompton Greaves Ltd. SSSG1215IH/FG STREETLIGHT LUMINAIRE
Luminous flux (Luminaire): 9650 lm Maximum luminous intensities
at 70: 137 cd/klm
at 80: 69 cd/klm
at 90: 5.79 cd/klm
Any direction forming the specified angle from the downward vertical, with the
luminaire installed for use.
Arrangement complies with luminous intensity class G3.
Arrangement complies with glare index class D.6.
Luminous flux (Lamps): 13500 lm
Luminaire Wattage: 173.0 W
Arrangement: Single row, bottom
Pole Distance: 20.000 m
Mounting Height (1): 7.000 m
Height: 6.911 m
Overhang (2): 0.000 m
Boom Angle (3): 10.0
Boom Length (4): 1.000 m
Page 2
Project 1
23.08.2014
Operator
Telephone
Fax
e-Mail
Street 1 / Luminaire parts li st
Crompton Greaves Ltd. SSSG1215IH/FG
STREETLIGHT LUMINAIRE
Article No.: SSSG1215IH/FG
Luminous flux (Luminaire): 9650 lm
Luminous flux (Lamps): 13500 lm
Luminaire Wattage: 173.0 W
Luminaire classification according to CIE: 99
CIE flux code: 49 82 98 99 71
Fitting: 1 x 150W HPSV-E (Correction Factor
1.000).
See our luminaire
catalog for an image of
the luminaire.
Page 3
Project 1
23.08.2014
Operator
Telephone
Fax
e-Mail
Street 1 / Photometric Resul ts
Light loss factor: 0.70 Scale 1:186
Calculation Field List
1 Valuation Field Roadway 2
Length: 20.000 m, Width: 4.000 m
Grid: 10 x 3 Points
Accompanying Street Elements: Roadway 2.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME4a (All lighting performance requirements are met.)
L
av
[cd/m]
U0 Ul TI [%] SR
Calculated values: 1.39 0.60 0.70 5 0.80
Required values according to class: 0.75 0.40 0.60 15 0.50
Fulfilled/Not fulfilled:
Page 4
Project 1
23.08.2014
Operator
Telephone
Fax
e-Mail
Street 1 / 3D Rendering
Page 5
Project 1
23.08.2014
Operator
Telephone
Fax
e-Mail
Street 1 / Fal se Col or Rendering
Page 6
Project 1
23.08.2014
Operator
Telephone
Fax
e-Mail
Street 1 / Valuation Field Roadway 2 / Results overvi ew
Light loss factor: 0.70 Scale 1:186
Grid: 10 x 3 Points
Accompanying Street Elements: Roadway 2.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME4a (All lighting performance requirements are met.)
L
av
[cd/m]
U0 Ul TI [%] SR
Calculated values: 1.39 0.60 0.70 5 0.80
Required values according to class: 0.75 0.40 0.60 15 0.50
Fulfilled/Not fulfilled:
Assigned observer (1 Pieces):
No. Observer Position [m]
L
av
[cd/m]
U0 Ul TI [%]
1 Observer 3 (-60.000, 2.000, 1.500) 1.39 0.60 0.70 5
Page 7
Project 1
23.08.2014
Operator
Telephone
Fax
e-Mail
Street 1 / Valuation Field Roadway 2 / Isolines (E)
Values in Lux, Scale 1 : 186
Grid: 10 x 3 Points
E
av
[lx] E
min
[lx] E
max
[lx]
u0
E
min
/ E
max
26 12 50 0.471 0.247
Page 8
Project 1
23.08.2014
Operator
Telephone
Fax
e-Mail
Street 1 / Valuation Field Roadway 2 / Greyscale (E)
Scale 1 : 186
Grid: 10 x 3 Points
E
av
[lx] E
min
[lx] E
max
[lx]
u0
E
min
/ E
max
26 12 50 0.471 0.247
Page 9
Project 1
23.08.2014
Operator
Telephone
Fax
e-Mail
Street 1 / Valuation Field Roadway 2 / Value Chart (E)
Values in Lux, Scale 1 : 186
Grid: 10 x 3 Points
E
av
[lx] E
min
[lx] E
max
[lx]
u0
E
min
/ E
max
26 12 50 0.471 0.247
Page 10
Project 1
23.08.2014
Operator
Telephone
Fax
e-Mail
Street 1 / Valuation Field Roadway 2 / Table (E)
3.333 36 29 20 15 12 12 15 21 29 36
2.000 45 35 24 17 13 13 17 25 36 46
0.667 49 37 25 17 14 13 18 26 39 50
m 1.000 3.000 5.000 7.000 9.000 11.000 13.000 15.000 17.000 19.000
Attention: The coordinates refer to the image above. Values in Lux.
Grid: 10 x 3 Points
E
av
[lx] E
min
[lx] E
max
[lx]
u0
E
min
/ E
max
26 12 50 0.471 0.247
Page 11
Project 1
23.08.2014
Operator
Telephone
Fax
e-Mail
Street 1 / Valuation Field Roadway 2 / Observer 3 / Isolines (L)
Values in Candela/m, Scale 1 : 186
Grid: 10 x 3 Points
Observer Position: (-60.000 m, 2.000 m, 1.500 m)
tarmac: R3, q0: 0.070
L
av
[cd/m]
U0 Ul TI [%]
Calculated values: 1.39 0.60 0.70 5
Required values according to class ME4a: 0.75 0.40 0.60 15
Fulfilled/Not fulfilled:
Page 12

Das könnte Ihnen auch gefallen